36
OVERLOAD RELAY
INSTALLATION INSTRUCTION SHEET
1
1009682
2 1011350
3 1011956
41053-292
OF
N/A
N/A
N/A
REVISION
AUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.
SIZE
SHEET
B
1234 56 78
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORE
SURFACE TREATMENT
(DIMENSIONS IN INCHES)
TOLERANCES UNLESS
OTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
41053
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
----------- -----------
-----------
-----------
-----------
-----------
E1 PLUS Features
Caract ristiques du E1 PLUS
Leistungsmerkmale des E1 PLUS
Caracter’sticas del E1 PLUS
Caracter’sticas E1 PLUS
Funzioni dell'E1 PLUS
(3)
=
FLA
1.73
S.F. < 1.15
S.F. _ _ FLA _ _
S.F.
>
1.15
Y
= .9 X FLA
= 1 X FLA
=
FLA
1.73
STAR DELTA (Y )
= 1 X FLA
DOL
FLA _ _
To adjust trip current, turn dial until the desired current is
aligned with the pointer. Trip rating is 120% of dial setting.
Pour régler l'intensité de déclenchement, tournez le cadran jusqu'à
ce que le pointeur soit sur l'intensité voulue. La valeur nominale
de déclenchement est de 120% du réglage cadran.
Zur Einstellung des Auslösestroms drehen Sie den Schalter, bis der
Zeiger auf die gewünschte Stromstärke zeigt. Der zur Auslösung
erforderliche Nennstrom beträgt 120% des eingestellten Wertes.
Per regolare la corrente di intervento, ruotare il regolatore fin quando la
corrente desiderata non è allineata con il puntatore . Il valore nominale
di intervento corrisponde al 120% dell'impostazione del regolatore.
Para regular a corrente de disparo, gire o disco mostrador até que
a corrente desejada esteja alinhada com o indicador . A classe
de disparo corresponde a 120% da marcação no mostrador.
Para ajustar la corriente del disparo, gire el dial hasta que la corriente
deseada esté alineada con la marca . La capacidad nominal del
disparo es el 120% del posicionamiento del dial.
E1 PLUS
E1 PLUS
120%
120%
RESET MODE
193*-EE
A
M
TRIP CLASS
10
15
20
30
Push to Reset
Enfoncer pour réinitialiser
Nullstellschalter
Presione para reiniciar
Pressione para religar
Premere per reimpostare
A = Automatic/Manual Reset Mode
A = Mode de réinitialisation automatique/manuel
A = Automatische/Manuelle Nullstellung
A = Modo de reinicio automático/manual
A = Modo de religação automático/manual
A = Modalità reimpostazione automatica/Manuale
M = Mode de réinitialisation manuel
M = Manuelle Nullstellung
M = Modo de reinicio manual
M= Modo de religação manual
M = Modalità reimpostazione manuale
Push To Test
Enfoncer pour tester
Testschalter
Presione para probar
Pressione para testar
Spingere per provare
Trip Indicator Window
Yellow indicator not visible: Not Tripped.
Yellow indicator visible: Tripped.
Ventana indicadora de disparo
Indicador amarillo no visible: No disparado
Indicador amarillo visible: Disparado
Visor de disparo
Se o indicador amarelo não estiver visível: não disparado
Se o indicador amarelo estiver visível: disparado
Finestra indicatrice di intervento.
Indicatore giallo non visibile: non scattato.
Indicatore giallo visibile: scattato.
Auslösungsanzeigefenster
Gelbe Anzeige nicht sichtbar: keine Auslösung
Gelbe Anzeige sichtbar: Auslösung
Fenêtre d'indicateur de déclenchement
Indicateur jaune non visible : pas de déclenchement
Indicateur jaune visible : déclenchement
Selectable Trip Class
Classe de déclenchement
sélectionnable
Wählbare Auslösestufen
Clase de disparo seleccionable
Seleção da classe de disparo
Classe di intervento selezionabile
M = Manual Reset Mode
A =
M =