TPI 2600 Series Guide d'installation

Taper
Guide d'installation
REV 05/14 ECO 1-6953 FORM: 8932
INSTALLATION INSTRUCTIONS
2600 SERIES DOWNFLOW HEATER
CHECK HEATER VOLTAGE AND PHASE ON DATA LABEL ON CONTROL PANEL DOOR TO MAKE SURE
THEY ARE THE SAME AS THE ELECTRIC SERVICE SUPPLY.
INSTALL SO THAT CENTERLINE OF HEATER IS NO CLOSER THAN 48” TO ADJACENT WALLS AND TOP
OF HEATING ELEMENT ENCLOSURE IS NO CLOSER THAN 15 1/2” TO CEILING (FACTORY SUPPLIED
MOUNTING BRACKET WILL MAINTAIN CORRECT DISTANCE TO CEILING).
NOTE:
Wiring diagrams of the heaters and supply connections are permanently attached to the inside of the
heater power wiring enclosure. All terminals are coded in accordance with the wiring diagram.
INSTALLATION INSTRUCTIONS
Heaters may be mounted using factory supplied accessory mounting equipment or using special facilities
supplied by user.
1.
Mount heater securely in the desired location.
2.
Remove desired knockout(s) on side of control panel.
3.
Open control panel cover at top of heater by loosening two screws, opening
latch, and trning disconnect handle to off position.
4. Following wiring diagram, connect power supply in accordance with local and/
or national codes. Be sure heater is properly grounded using grounding lug
provided. Floor level thermostat control may be either low or line voltage
depending on individual heater control voltage, check heater data plate
before thermostat installation
.
NOTE: Only one heater may be controlled by a thermostat.
Wiring instructions, where required for remote controls are packed with each individual control. See wiring
diagram on heater access panel for wiring to heater.
After installation is complete, depress RED reset button(s) to insure continuity before applying power to unit.
OPERATION

shall be energized and remain so until the temperature reaches the setting of the thermostat; at which time,
the heating element(s) shall be d-energized. The fan motor shall continue to run and purge the heater casing
of residual heat until the setting of the fan override is reached, then the fan motor shall be d-energized. For


thermostat shall energize the second stage heating element. Upon a rise in space conditions towards the setting
of the thermostat, the two stages of heating elements shall be d-energized in sequence. The fan motor shall
continue to run and purge the heater casing of residual heat until the setting of the fan override is reached, then
the fan motor shall be d-energized.
1
REV 05/14 ECO 1-6953 FORM: 8932
OPERATION CONTINUED
The manual reset safety high limit shall d-energize the heating element(s) and/or control circuit should the temperature
exceed the setting of this device.
The fan safety override shall energize the fan motor any time the setting of this device is exceeded so as to purge the heater
casing of excess residual heat.

be energized.
NOTE: The thermostat is to be set to the OFF position during this mode of operation.
NOTE: EXCEPT IN CASES OF EMERGENCY, DO NOT OPEN MAIN DISCONNECT WHILE HEATER IS IN OPERATION.
THIS DISCONNECTS ALL POWER TO THE HEATER PREVENTING THE FAN FROM PURGING THE HEATING
ELEMENTS OF RESIDUAL HEAT AND MAY RESULT IN THE THERMAL CUT-OUT(S) OPENING.
THERMAL CUT-OUTS
If for any reason heater temperatures increase beyond normal limits, safety thermal cut-out(s) will open, d-energizing the
heating element(s) and/or control circuits. Check entire installation to determine cause of overheating and after corrective
measures have been taken, push thermal reset button(s) on side of power wiring enclosure.
MAINTENANCE/CLEANING
IN CLEANING OR DISASSEMBLING HEATER, BE SURE TO DISCONNECT HEATER POWER CIRCUIT.
Heaters up to capacities of 20KW have permanently lubricated motors and therefore no maintenance other than occasional
cleaning is required.
Heaters over 20KW have motors which should be oiled once a season with S.A.E. No. 10 motor oil.
Motor and guard assembly can be removed for cleaning without removing heater from the ceiling as follows:
Remove optional diffuser is heater is so equipped. Disconnect motor and the capacitor leads inside power wiring enclosure.
Remove motor conduit locknut. Remove four nuts and lockwashers which hold motor mount assembly to inside top of
heater. To reassemble, reverse the above procedure.
2
REV 05/14 ECO 1-6953 FORM: 8932
IMPORTANT INSTRUCTIONS

and injury to persons, including the following:
1. Read all instructions before using this heater.
2. CAUTION:
High temperatures. Keep cords and all other combustible material, such as furniture, papers, clothes

heater of three feet in front and 12 inches at ends and rear.
ATTENTION:
Les températures élevées. Gardez les cordons et tout autre matériau combustible, tels que les
meubles, papiers, vêtements et rideaux à l’extérieur de l’appareil de chauffage. Pour un

12 pouces aux extrémités et à l’arrière.
3. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions, has been dropped or damaged in any manner. Return heater to
authorized service facility for examination, electrical or mechanical adjustment, or repair.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel (or operate
internal disconnect switch if provided).
7. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric chock

8. 
9. A heater has hot and arcing or sparking parts inside. WARNING: Do not use it in area where gasoline, paint, or

10. 
electric shock, or injury to persons.
11. This heater may include an audible or visual alarm to warn that parts of the heater are getting excessively, hot. If the
alarm sounds (or illuminates), immediately turn the heater off and inspect for any objects on or adjacent to the heater

DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING).
11. SAVE THESE INSTRUCTIONS
3
  • Page 1 1
  • Page 2 2
  • Page 3 3

TPI 2600 Series Guide d'installation

Taper
Guide d'installation

dans d''autres langues