TPI HV-2 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

1 of 2 ECO1-7538 FORM: 8217
Industrial Air Circulator Instructions
For All HV-2 and HV-3 Accessory Brackets
READ AND SAVE THESE IMPORTANT INSTRUCTIONS
The TPI HV-2 wall mount assembly is intended for use with TPI 18 and 24 inch High Velocity Fans: HV 18 and
HV 24.
The TPI HV-3 wall mount assembly is intended for use with TPI 18, 24, and 30 inch High Velocity Fans: HV
18, HV 24, and HV 30.
It is important that the following safety precautions be followed when using this product:
DO NOT use HV-2 with models beginning with HV 30.
• WARNING: To reduce the risk of re, electrical shock, or injury to persons, observe the following: Use this
unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer
.
Installation work and electrical wiring must be done by qualied person(s) in accordance with all
applicable codes and standards,including re-rated construction.
When cutting into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Avertissement: Pour reduire les risques d’incendie ou de choc electrique, ou de blessures, respectez les
consignes suivantes:
Utiliser cette unite uniquement de lamaniere prevue par le fabricant. Si vous avez des questions, contactez
le fabricant.
lorsque la moyenne de la deconnexion n’est pas bloque, fixez solidement un avertissement bien
en evidence, comme une etquette sur le panneau de service.
Les travaux d’installation et decablage
electrique
doivent etre eectues par des personnes qualiees
conformement a tous les codes et normes
applicables, y compris la construction par incendie.
Lorsque vous coupez dans le mur ou le plafond, n’endommagez pas le cablage electrique et d’autres
utilitaires caches.
ECO1-7538 FORM: 8217
2 of 2
INSTALLATION INSTRUCTIONS
For installation on wood structures, use 1/2" lag screws of appropriate length for the application.
For installation on steel structures, use a 1/2" bolts of the appropriate length for the application, in combination
with a at washer, a lock washer and a 1/2" nut
.
For installation on masonry structures, use a 1/2" lag screw, in combination with a lag shield, of appropriate
length for the application.
Use wall mount tubing bracket as a template for locating the holes to be drilled on mounting surface. Use an
appropriately sized drill bit and drill holes through mounting surface.
Attach wall mount tubing bracket to mounting surface using hardware not provided. It is recommended that a
minimum of grade 5 fasteners be used.
Assemble wall mount support arm and gusset plates as shown above with 1/2” bolts, steel washers, nylon washers, and
nylon insert lock nuts. Securely tighten all fasteners. Note that assembly may be mounted as shown with the fan above
the bracket or inverted with the fan hanging below the bracket.
Attach TPI HV Fan to wall mount assembly as shown above. Securely tighten all fasteners.
For additional information on TPI Products or replacement parts, call TPI Customer Service Department at 1-800-251-0382
or write the address below.
PO. Box 4973 • Johnson City, Tennessee 37602-4973 • 423-477-4131 • FAX 423-477-0683
(8.00)
(16.00)
(Ø.563)
3X
HV FAN YOKE
NOT INCLUDED
FLAT WASHER
1/2" X 5" BOLT
FLAT WASHER
HEX NUT WITH
NYLON INSERT
1/2" X 5" BOLT HEX NUT WITH
NYLON INSERT
GUSSET PLATE
BOTH SIDES
19.50
21.81
4.00
20.25
3.38
8.00
16.00
2.13
HV-2
.563
3.38
20.25
22.50
24.81
8.00
16.00
2.13
HV-3
.563
4.00
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

TPI HV-2 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues