JENNAIR® 30" AND 36" (76.2 CM AND
91.4 CM) WALL-MOUNT CANOPY HOOD
HOTTE D’EXTRACTION À MONTAGE MURAL
DE 30 ET 36 PO (76,2 CM ET 91,4 CM)
JENNAIR®
W11508875A
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.ca.
Instructions d’installation et Guide d’utilisation et d’entretien
Pour des questions à propos des caractéristiques, du fonctionnement/rendement, des pièces, accessoires ou dépannage, composer le
1800JENNAIR (1800536-6247) ou visiter notre site Web au www.jennair.com.
Au Canada, composer le 1800JENNAIR (1800536-6247) ou visiter notre site Web au www.jennair.ca.
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT: LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE
UNIQUEMENT.
2
TABLE OF CONTENTS TABLE DES MATIÈRES
HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You can be killed or seriously injured if you don't follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
HOOD SAFETY ...............................................................................2
INSTALLATION REQUIREMENTS ................................................. 4
Tools and Parts .............................................................................4
Location Requirements ................................................................4
Venting Requirements ..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ................................................... 7
Prepare Location ..........................................................................7
Assemble and Install Hood ..........................................................8
Make Electrical Connection .......................................................10
Install Duct Covers .....................................................................11
HOOD USE ....................................................................................12
Controls and Features ................................................................ 12
HOOD CARE .................................................................................13
User Servicing and Maintenance Instructions ...........................13
WIRING DIAGRAM .......................................................................14
ASSISTANCE OR SERVICE .........................................................15
In the U.S.A. ...............................................................................15
In Canada ...................................................................................15
Accessories ................................................................................15
SÉCURITÉ DE LA HOTTE ............................................................16
EXIGENCES D’INSTALLATION ...................................................18
Outils et pièces ...........................................................................18
Exigences d’emplacement .........................................................18
Exigences concernant l’évacuation ...........................................19
Spécications électriques ..........................................................20
INSTRUCTIONS D’INSTALLATION ............................................21
Préparation de l’emplacement ...................................................21
Assembler et installer la hotte ....................................................23
Raccordement électrique ...........................................................24
Installation des cache-conduits .................................................25
UTILISATION DE LA HOTTE .......................................................26
Commandes et caractéristiques ................................................27
ENTRETIEN DE LA HOTTE .........................................................28
Instructions aux utilisateurs sur l’entretien et la maintenance ..28
SCHÉMA DE CÂBLAGE ...............................................................29
ASSISTANCE OU SERVICE .........................................................30
Aux É.-U. ....................................................................................30
Au Canada ..................................................................................30
Accessoires ................................................................................30
3
IMPORTANT SAFETY INSTRUCTIONS
READ
AND
SAVE
THESE
INSTRUCTIONS
For General Ventilating Use Only. Do Not Use
To Exhaust Hazardous Or Explosive Materials And Vapors.
This appliance is not intended for use by people (including
children) whose physical, sensory or mental capacities are
different or impaired or who lack the necessary experience
or knowledge/expertise to do so, unless such persons are
supervised or are trained to operate the appliance by a
person who accepts responsibility for their safety.
To Reduce The Risk Of Fire Or Electric
Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
Ducted fans must always be vented to the outdoors.
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read
and follow the instructions provided with any tools listed here.
Tools needed
Level
Drill with 1¼" (3 cm), 3/8" (9.5 mm), 7/64" (2.75 mm) and
1/8" (3 mm) drill bits
Pilot hole drill bits (determined by chimney support attachment
method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Ladder
Hacksaw
Parts needed
Home power supply cable
1/2" (12.7 mm) UL listed or CSA approved strain reliefs (2)
UL listed wire connectors (3)
For vented installations, you will also need:
Wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also need:
Recirculating Kit for non-vented (recirculating) installations only.
See “Assistance or Service” section to order.
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Ø4x8 mm
Ø8x40 mm Ø5x45 mm Ø3.5x9.5 mm Ø2.9x6.5 mm
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the hood. It is the installer's
responsibility to comply with installation clearances specied
on the model/serial/rating plate. The model/serial rating plate is
located behind the left lter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
Because of the size and weight of this wall hood, the chimney
support must be securely attached to the wall.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 100 lbs (45.4 kg).
IMPORTANT: The means of xing supplied with the hood, are
exclusively suitable for xing on concrete or brick ceiling.
Ask a qualied technician to indicate which fasteners should be
used depending on the type of wall/ceiling in the home.
For the various wall or ceiling mounted installations, use screws
and dowels suited to the type of structural material (e.g. cement,
wood, etc.).
Check that the screws and dowels supplied with the product
are suited to the type of wall/ceiling on which the hood will be
mounted.
A qualied technician must ensure the wall/ceiling where the
hood will be installed is solid enough to support the weight of
the product.
If not, prepare a suitable frame for said purpose.
This hood is recommended for use with cooktops with a
maximum total rating of 90,000 BTUs or less on 600 CFM models
and 62,000 BTUs or less on 400 CFM models.
The hood is factory set for venting through the roof.
For non-vented (recirculating) installation, see “Non-vented
(recirculating) Installations” in “Assemble and Install Hood”
section. Recirculation Kit Part Number W11522798 is available
from your dealer or an authorized parts distributor.
All openings in ceiling and wall where hood will be installed must
be sealed.
For Mobile Home Installations
The installation of this hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280) or when such standard is
not applicable, the standard for Manufactured Home Installation
1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A, or latest edition, or with local codes.
Product Dimensions
G
F
E
D
C
B
A
A. 127/16" (31,6 cm)
B. 127/16" (32 cm)
C. 2915/16" (76 cm)
356/16" (89,6 cm)
D. 171/16" (43.4 cm)
E. 26/16" (6.0 cm)
F. 2612/16" (67.9 cm)
G. **2715/16" (71.0 cm) minimum
***474/16" (120.0 cm) maximum
*Vented installations only
**Non-vented (recirculating) installations only
5
Installation Dimensions
1113/16" (30 cm) minimum
1210/16" (32 cm) minimum
312/16" (9.5 cm) 110/16" (4.2 cm)
1113/16" (30 cm) minimum
1210/16" (32 cm) minimum
192/16" (48.5 cm)
30" (76.2 cm)
36" (91.4 cm)
Side cabinet Side cabinet
"X"
bottom of
canopy to
cooking surface Centerline
Cooking surface
Vent and
power supply
cable entry
location
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 30" (76.2 cm) from electric cooking
surface.
Minimum distance “X”:30" (76.2 cm) from gas cooking surfaces.
Suggested maximum distance “X”: 36" (91.4 cm).
Vented Installations
Minimum ceiling
height Maximum ceiling
height
Electric cooking
surface 7' 10" (2.39 m) 10' 4" (3.24 m)
Gas cooking
surface 8' 4" (2.54 m) 10' 4" (3.24 m)
Non-vented (Recirculating) Installations
Minimum ceiling
height Maximum ceiling
height
Electric cooking
surface 7' 10" (2.39 m) 10' 4" (3.24 m)
Gas cooking
surface 8' 4" (2.54 m) 10' 4" (3.24 m)
*NOTE: The hood chimneys are adjustable and designed to
meet varying ceiling or soft heights depending on the distance
“C” between the bottom of the hood and the cooking surface.
For higher ceilings, a Stainless Steel Chimney Extension Kit
Part Number is available from your dealer or an authorized parts
distributor. The chimney extension replaces the upper chimney
shipped with the hood.
Venting Requirements
Vent system must terminate to the outside, except for
non- vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Do not use plastic or metal foil vent.
The vent system must have a damper. If the roof or wall cap has
a damper, do not use the damper supplied with the hood.
For the most efcient and quiet operation:
Use a straight run or as few elbows as possible.
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight vent
between the elbows, if more than 1 elbow is used.
Do not install 2 elbows together.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of air
movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
6
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, tting a charcoal lter and the deector. Fumes and
vapors are recycled through the top grille.
Roof venting Wall Venting Non-vented
(recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deector
B. 6" (15.2 cm)
round vent
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent ft (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum vent length of
35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
GROUNDING INSTRUCTIONS
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualied electrician if you are not sure hood is
properly grounded.
Do not have a fuse in the neutral or ground circuit.
Consult a qualied electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether the
appliance is properly grounded.
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current.
WARNING: Improper grounding can result in a risk of electric
shock.
Only for appliances provided with power supply cord:
This appliance is equipped with a cord having a grounding wire
with a grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualied electrician install an outlet near the
appliance.
Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
Do not run cord under carpeting.
Do not cover cord with throw rugs, runners, or similar coverings.
Do not route cord under furniture or appliances.
Arrange cord away from trafc area and where it will not be
tripped over.
The hood should be connected directly to the fused disconnect
(Or circuit breaker).
Wire sizes must conform to the requirements of the National
Electrical Code ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2
No. 0-M91 - latest edition** and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
90 elbow Wall cap
6 ft (1.8 m)
2 ft
(0.6 m)
7
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed before the
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling for exhaust vent.
Hood is to be installed 30" (76.2 cm) minimum for electric
cooking surfaces, 30" (76.2 cm) minimum for gas cooking
surfaces, to a suggested maximum of 36" (91.4 cm) above the
cooking surface.
Check your ceiling height and the hood height maximum before
you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
non-vented.
3. Select a at surface for assembling the hood. Place covering
over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift hood onto covered surface.
Hood Mounting Screws Installation
1. Establish and mark the center line on the wall where the hood
will be installed, as indicated in gure.
2. Tape the template sheet so the lower edge of the sheet
representing the bottom of the hood is at a mounting height
between a minimum of 30" (76.2 cm) for an electric cooking
surface, a minimum of 30" (76.2 cm) for a gas cooking
surface, and a suggested maximum of 36" (91.4 cm) for both
gas and electric cooking surfaces. Drill 3 holes as shown in
gure.
4 x Ø8 mm
3. Install three Ø8 x 40 mm dowels. Install two Ø5 x 45 mm
screws as shown in gure.
4. Make sure the screw has at least 10 mm distance from the
wall when it is screwed for hood mounting as shown in gure.
10 mm
3x
Ø8x40 mm
2x
Ø5x45 mm
5. Take the chimney xing bracket, adjust the bracket with the
width of the pipe and couple it with 4 screws Ø4x8 mm as
shown in gure, steps 1-2-3-4.
Ø4x8 mm
6. Position the bracket: The center line drawn will facilitate
the correct positioning of the bracket.Mark the 2 holes for
wall mounting, drill the holes Ø8 mm and install 2 plugs
Ø8 x45 mm and nally x the bracket with the two screws
Ø5x45 mm, as shown in gure.
2 x Ø8 mm
Ø8 x 40 mm Ø5 x 45 mm
7. Prearrange the air duct outlet hole, only in the Exhaust
version.
8. The diameter of the air outlet hole in the wall must be
Ø160 mm, taking into account the measurements indicated
in gure. Make sure the hole does not coincide with the
electrical system.
8
9. Check that there are no ducts or pipes on the wall that they
might make installation impossible as shown in gure.
10. If, instead, the hood has been installed with a recirculation kit,
the air diverter is included in the supply and must be adjusted
according to the width of the pipe and xed with two screws
Ø3.5x9.5 mm as shown in gure.
2x
Ø3.5x9.5 mm
11. Take the air diverter and x it to the wall bracket previously
xed, with 4 screws Ø3.5x9.5 mm as shown in gure.
Ø3.5x9.5 mm
NOTE: For better
handling of the
hood, before
proceeding with
installation, remove
the perimeter
suction panel and
the grease lter,
as shown in gure,
steps 1-2-3-4.
12. For vented installations only: Using a jigsaw or keyhole saw,
cut a 6½" (16.5 cm) diameter hole for the vent duct.
NOTE: Your hood can work with either an internal or an
in-line (external) blower motor system. An optional In-Line Smart
Kit (purchased separately) allows the blower motor that comes
with this hood to be installed in a location other than inside the
hood cavity.
CAUTION: To reduce the risk of re and electric shock, install this
hood only with the In-Line Smart Kit manufactured by Whirlpool,
W10692945.
For installation see the In-Line Smart Kit installation instructions.
See the “Assistance or Service” section to order.
Assemble and Install Hood
1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
Ø3.5x9.5 mm
9
2. Hang the hood with the help of at least two people on the two
screws previously xed to the wall as shown in gure.
3. Tighten the two screws and denitively x the hood to the
wall with the Ø5x45 mm safety screw and washer as shown in
gure.
Ø 5x45 mm
4. Remove the sticker from the electrical system box as shown
in gure and follow steps 1-2-3.
5. Fixing the air outlet pipe in the Exhaust version or in the
Recirculation version gure 16. Use a pipe with a diameter no
smaller than that of the hood connection and the minimum
number of bends required. adjust and if necessary cut off
the excess pipe. The tube must be purchased and must be
compatible with the regulations in force in your country.
6. Fix the tube to the lower part of the product and connect it
to the external outlet in the Exhaust version, and to the air
diverter in the Recirculation version gure.
*
7. The kit is composed of a carbon lter, a bracket and 4 screws
Ø3.5x9.5 mm, the bracket must be xed to the lower part of
the hood with the 4 screws supplied, gure.
Ø3.5x9.5 mm
Ø6''
Ø152 mm
10
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box, and then install a
UL listed or CSA approved 1/2" (12.7 mm) strain relief.
4. Run home power supply cable through strain relief and into
the terminal box.
5. Use UL listed wire connectors and connect black wires (L)
together.
6. Use UL listed wire connectors and connect white wires (N)
together.
Ø3.5x9.5 mm
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the “Assistance or Service”
section for information on ordering.
NOTE: Use only with hood cord connection kits that have been
investigated and found acceptable for use with this model hood.
11
Install Duct Covers
NOTE: Remove the lm from the duct covers.
1. In the Exhaust version, the grill faces downwards and in the
Recirculation version, the grill faces upwards as shown in
gure. Position the tubes on the hood, take the upper tube
and x it to the bracket with the two screws Ø2.9x6.5 mm as
indicated in step 1-2.
Ø2.9x6.5 mm
2. If the product is in the Recirculation version, place the carbon
lter on the bracket as shown in gure.
3. Reposition the grease lters in their seats as shown in gure.
4. Reposition the perimeter suction panel as shown in gure,
phase 1-2-3.
12
HOOD USE
The hood is designed to remove smoke, cooking vapors and
odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the front side of the canopy.
A. Louver holes (non-vented
[recirculating] installations only)
B. Upper duct covers
C. Lower duct covers
D. LED lights (1)
E. Metal grease lters (located
behind the perimetic cover)
F. Perimetic cover
G. Canopy
H. Control panel
Controls and Features
The hood is tted with a control panel with aspiration speed
selection control and a light switch to control cooking area lights.
T1 = Motor ON/OFF button - 1st speed.
T2 = 2nd speed.
T3 = 3rd speed.
T4 = 4th Speed.
Timed On/Off Boost, after 5 minutes the hood returns to the
previously set speed.
T5 = Light ON/OFF button.
T6 = Reset Button for lters:
The lters must always be reset with the motor running.
The hood will warn the user that it is time to do maintenance work
on the lters, by giving out a light-signal.
Flashing Button: carry out the maintenance of the greasy lters,
following this press the button for over 3 seconds and the button
will turn off.
Lit Button: carry out maintenance on carbon-lters, following this
press the button for more than 3 seconds, the button will switch
off.
Attention: the hood is provided only with a warning signal for
greasy lters.
To put into function the greasy-lter signal:
Set the hood off, press switch button number 6 for more than 3
seconds, the switch will turn on signalling that the function has
been set.
To deactivate the carbon lter signal, repeat the entire procedure
again.
Functions
Fan Speeds
Min Press MIN FAN to turn the fan on at Minimum
speed.
Med Press MED FAN to turn the fan on at Medium
speed.
Max Press MAX FAN to turn the fan on at Maximum
speed.
Boost Press BOOST to turn the fan on at the highest
speed. Boost will automatically turn Off after
5 minutes and the fan will switch to High speed.
Control Panel
13
Timer
The hood can be set to turn Off automatically after 15 minutes.
1. Press and hold the desired fan speed button for 2 seconds.
The fan will run on the chosen speed for 15 minutes, and the
fan speed button light will ash continuously.
After 15 minutes, the fan will turn Off automatically.
2. Press the desired fan speed button again while the fan timer is
running to cancel the fan timer.
NOTE: Changing the fan speed or turning Auto Sense On will
also cancel the 15 minute timer.
Filter
The Filter button lights up when it is time to replace or clean the
lter. The button will be lit only when the fan is On. Press FILTER
after replacing the lter to turn the Filter button light Off. See the
“Cleaning” section for how to replace or clean the lter.
Light
Press LIGHT to turn the hood lights On and Off.
HOOD CARE
User Servicing and Maintenance Instructions
Cleaning:
Clean using ONLY a cloth dampened with neutral liquid detergent.
DO NOT CLEAN WITH TOOLS OR INSTRUMENTS.
Do not use abrasive products. DO NOT USE ALCOHOL.
Steam screen:
The steam screen must always be left closed and opened only for
maintenance (e.g. cleaning or changing lters).
Grease lter
Traps cooking grease particles.
This must be cleaned once a month (or when the lter saturation
indication system – if signaled on the model in possession-
indicates this necessity) using non aggressive detergents,
either by hand or in the dishwasher, which must be set to a low
temperature and a short cycle. When washed in a dishwasher,
the grease lter may discolor slightly, but this does not affect its
ltering capacity.
Charcoal lter (For Recirculating Installations)
It absorbs unpleasant odors caused by cooking.
The charcoal lter can be washed once every two months (or
when the lter saturation indication system – if signaled on the
model in possession – indicates this necessity) using hot water
and a suitable detergent, or in a dishwasher at 65°C (if the
dishwasher is used, select the full cycle function and leave dishes
out). Eliminate excess water without damaging the lter, then put
it in the oven for 10 minutes at 212°F (100°C) to dry completely.
Replace the lter every 3 years and when the cloth is damaged.
Replacing lamps
The hood is equipped with a lighting system based on LED
technology.
The LEDs guarantee an optimum lighting, a duration up to
10 times longer than the traditional lamps and allow to save 90%
electrical energy.
For replacement, contact the technical service.
14
WIRING DIAGRAM
15
ASSISTANCE OR SERVICE
If you need replacement parts
If you need to order replacement parts, we recommend that
you use only factory specied parts. Factory specied parts will
t right and work right because they are made with the same
precision used to build every new appliance.
To locate factory specied replacement parts in your area, call the
following customer assistance telephone number or your nearest
designated service center.
In the U.S.A.
Call JennAir Customer eXperience Center toll free:
1-800-JENNAIR (1-800-536-6247) or visit our website at
www.jennair.com.
Our consultants provide assistance with:
Scheduling of service. JennAir
®
appliances designated service
technicians are trained to fulll the product warranty and provide
after-warranty service anywhere in the United States.
Features and specications on our full line of appliances.
Referrals to local JennAir
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
For further assistance
If you need further assistance, you can write to JennAir®
Appliances with any questions or concerns at:
JennAir Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada LP Customer eXperience Centre toll
free at 1-800-JENNAIR (1-800-536-6247) or visit our website at
www.jennair.ca.
Our consultants provide assistance with:
Scheduling of service. JennAir
®
appliances designated service
technicians are trained to fulll the product warranty and provide
after-warranty service anywhere in the Canada.
Features and specications on our full line of appliances.
Referrals to local JennAir
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
For further assistance
If you need further assistance, you can write to JennAir®
Appliances with any questions or concerns at:
JennAir Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Chimney Kit 10.5 ft-12.1 ft (3.2 m-3.7 m)
Order Part Number W11522794
Chimney Kit 8.9 ft-10.5 ft (2.7 m-3.2 m)
Order Part Number W11522796
Charcoal Filter Kit - Recirculating Kit
(for non-vented installations only)
Order Part Number W11522798
Filter Kit - Replacement
Order Part Number W11522797
6" (15.2 cm) Makeup Air Kit
(consult local building codes)
Order Part Number W10446915
16
SÉCURITÉ DE LA HOTTE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
17
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
LIRE ET CONSERVER CES INSTRUCTIONS
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, RESPECTER LES INSTRUCTIONS
SUIVANTES :
Utiliser cet appareil uniquement dans les applications
envisagées par le fabricant. Pour toute question, contacter
le fabricant.
Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre l'alimentation de la hotte au niveau du tableau
de disjoncteurs, et verrouiller le tableau de disjoncteurs
pour empêcher tout rétablissement accidentel de
l'alimentation du circuit. Lorsqu'il n'est pas possible de
verrouiller le tableau de disjoncteurs, placer sur le tableau
de disjoncteurs une étiquette d'avertissement proéminente
interdisant le rétablissement de l'alimentation.
Tout travail d'installation ou câblage électrique doit être
réalisé par une personne qualifiée, dans le respect des
prescriptions de tous les codes et normes applicables, y
compris les codes du bâtiment et de protection contre les
incendies.
Ne pas faire fonctionner un ventilateur dont le cordon ou la
fiche est endommagé(e). Jeter le ventilateur ou le retourner
à un centre de service agréé pour examen et/ou réparation.
Une source d'air de débit suffisant est nécessaire pour le
fonctionnement correct de tout appareil à gaz (combustion
et évacuation des gaz à combustion par la cheminée), pour
qu'il n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de l'équipement de chauffage et
les prescriptions des normes de sécurité - comme celles
publiées par la National Fire Protection Association (NFPA)
et l'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorités réglementaires locales.
Lors des opérations de découpage et de perçage dans un
mur ou un plafond, ne pas endommager les câblages
électriques et les canalisations qui peuvent s’y trouver.
Les ventilateurs d'évacuation doivent toujours décharger
l'air à l'extérieur.
MISE EN GARDE : Cet appareil est conçu uniquement
pour la ventilation générale. Ne pas l'utiliser pour
l'extraction de matières ou vapeurs dangereuses ou
explosives.
MISE EN GARDE : Pour minimiser le risque d'incendie
et évacuer adéquatement les gaz, veiller à acheminer l'air
aspiré par un conduit jusqu'à l'extérieur - ne pas décharger
l'air aspiré dans un espace vide du bâtiment comme une
cavité murale, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE
D'INCENDIE, UTILISER UNIQUEMENT DES CONDUITS
MÉTALLIQUES.
AVERTISSEMENT : POUR MINIMISER LE RISQUE
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE :
Ne jamais laisser un élément de surface fonctionner à
puissance de chauffage maximale sans surveillance. Un
renversement/débordement de matière graisseuse pourrait
provoquer une inflammation et la génération de fumée.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
Veiller à toujours faire fonctionner le ventilateur de la hotte
lors de la cuisson avec une puissance de chauffage élevée
ou lors de la cuisson d'un mets à flamber (à savoir crêpes
Suzette, cerise jubilée, steak au poivre flambé).
Nettoyer fréquemment les ventilateurs d'extraction. Veiller à
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
Utiliser toujours un ustensile de taille appropriée. Utiliser
toujours un ustensile adapté à la taille de l'élément
chauffant.
AVERTISSEMENT : POUR RÉDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRÈS LE DÉCLENCHEMENT
D'UN FEU DE GRAISSE SUR LA CUISINIÈRE, APPLIQUER
LES RECOMMANDATIONS SUIVANTES :a
Placer sur le récipient un couvercle bien ajusté, une tôle à
biscuits ou un plateau métallique POUR ÉTOUFFER LES
FLAMMES, puis éteindre le brûleur. VEILLER À ÉVITER
LES BRÛLURES. Si les flammes ne s'éteignent pas
immédiatement, ÉVACUER LA PIÈCE ET APPELER LES
POMPIERS.
NE JAMAIS PRENDRE EN MAIN UN RÉCIPIENT
ENFLAMMÉ - vous risquez de vous brûler.
NE PAS UTILISER D'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brûlante.
Utiliser un extincteur SEULEMENT si :
– Il s'agit d'un extincteur de classe ABC, dont on connaît le
fonctionnement.
– Il s'agit d'un petit feu encore limité à l'endroit où il s'est
déclaré.
– Les pompiers ont été contactés.
– Il est possible de garder le dos orienté vers une sortie
pendant l'opération de lutte contre le feu.
aRecommandations tirées des conseils de sécurité en cas
d'incendie de cuisine publiés par la NFPA.
AVERTISSEMENT : Pour réduire le risque d'incendie
ou de choc électrique, ne pas utiliser ce ventilateur avec un
quelconque dispositif de réglage de la vitesse à
semi-conducteurs.
Cet appareil ne convient pas à une utilisation par des
personnes (y compris des enfants) dont les capacités
physiques, sensorielles ou mentales sont différentes ou
réduites ou qui ne possèdent pas l’expérience, les
connaissances ou l’expertise nécessaire, à moins d’être
supervisées ou d’avoir reçu des instructions concernant
l’utilisation par une personne responsable de leur sécurité.
18
EXIGENCES D’INSTALLATION
Outils et pièces
Rassembler les outils et pièces nécessaires avant d’entreprendre
l’installation. Lire et observer les instructions fournies avec
chacun des outils de la liste suivante.
Outils nécessaires
Niveau
Perceuse avec forets de 1 ¼ po (3cm), 3/8 po (9,5mm),
7/64 po (2,75mm) et 1/8 po (3,0mm)
Foret (pour les avant-trous, selon la méthode de fixation du
support de cheminée)
Crayon
Pince à dénuder ou couteau à lame rétractable
Ruban à mesurer ou règle
Pince
Pistolet à calfeutrage et calfeutrant étanche
Brides de conduit
Scie sauteuse ou scie à guichet
Tournevis à tête plate
Cisaille à métaux
Tournevis à tête cruciforme
Échelle
Scie à métaux
Pièces nécessaires
Câble d’alimentation électrique du domicile
2 serre-câbles de 1/2 po (12,7mm) (homologation UL ou CSA)
3 connecteurs de fils homologués UL
Pour les installations avec décharge à l’extérieur, il vous
faudra aussi:
Bouche de décharge murale ou à travers le toit
Circuit d’évacuation métallique
Pour les installations sans décharge à l’extérieur (recyclage),
il vous faudra aussi:
Ensemble de recyclage pour cache-conduit, pour installations
sans décharge à l’extérieur (recyclage) uniquement. Voir la
section « Assistance ou service » pour commander.
Conduit métallique d’un diamètre de 6po (15,2cm). La longueur
nécessaire est fonction de la hauteur sous plafond.
Pièces fournies
Retirer les pièces de leur emballage. Vérifier que toutes les pièces
sont présentes.
Ø4x8 mm
Ø8x40 mm Ø5x45mm Ø3,5x9,5mm Ø2,9x6,5mm
Exigences d’emplacement
IMPORTANT: Observer les dispositions de tous les codes et
règlements en vigueur.
Confier l’installation de la hotte à un technicien qualifié. C’est
à l’installateur qu’incombe la responsabilité de respecter les
distances de séparation spécifiées sur la plaque signalétique.
La plaque signalétique de l’appareil est située derrière le filtre de
gauche, sur la paroi arrière de la hotte.
On doit toujours installer la hotte à distance des sources de
courant d’air (fenêtres, portes et bouches de chauffage).
Les dimensions d’ouverture de l’armoire indiquées doivent être
utilisées.
Ces dimensions représentent les valeurs minimales des
dégagements.
Une prise électrique avec liaison à la terre est nécessaire. Voir la
section « Spécifications électriques ».
En raison du poids et de la taille de cette hotte pour mural, il faut
que le support de cheminée soit solidement fixé au mural.
Pour un plafond en plâtre ou en panneaux de gypse, le support
de cheminée doit être fixé aux solives. Si ce n’est pas possible,
on doit construire une structure de support appropriée derrière
le plafond en plâtre ou panneaux de gypse. Le support doit être
capable de soutenir une charge de 100lb (45,4kg).
IMPORTANT: Le matériel de fixation accompagnant la hotte est
conçu exclusivement pour un plafond en béton ou en briques.
Demander à un technicien qualié de vous indiquer quels
dispositifs de xation conviennent au type de mur/plafond de
votre maison.
Pour les différentes installations au mur ou au plafond, utiliser
des vis et chevilles qui conviennent au type de matériaux de la
structure (p. ex., béton, bois, etc.).
Vérier que les vis et chevilles fournies avec le produit
conviennent au type de mur/plafond où la hotte sera installée.
Un technicien qualié doit s’assurer que le mur/plafond où la
hotte sera installée est sufsamment solide pour supporter le
poids du produit.
Si ce n’est pas le cas, préparer un cadre qui conviendra à
l’utilisation.
Il est recommandé d’utiliser cette hotte avec une table de cuisson
d’une puissance maximum de 90 000 BTU ou moins sur les
modèles 600 CFM et 62 000 BTU ou moins sur les modèles
400 CFM.
19
Cette hotte a été configurée à l’usine pour une décharge à travers
le toit.
Pour une installation sans décharge à l’extérieur (recyclage), voir
le point « Installations sans décharge à l’extérieur (recyclage) » à la
section « Assembler et installer la hotte ». La trousse de recyclage
(numéro de pièceW11522798) est disponible chez votre
marchand ou chez un distributeur de pièces autorisé.
Toutes les ouvertures dans le plafond et le mur de l’emplacement
d’installation de la hotte doivent être scellées.
Pour une installation dans une résidence mobile
L’installation de cette hotte doit s’effectuer conformément aux
descriptions de la norme Manufactured Home Construction
Safety Standards, Title24 CFR, Part328 (anciennement Federal
Standard for Mobile Home Construction and Safety, title24, HUD,
Part280) ou lorsque cette norme n’est pas applicable, utiliser
la norme Standard for Manufactured Home Installations1982
(Manufactured Home Sites, Communities and Setups)
ANSIA225.1/NFPA501A ou respecter les dispositions des codes
locaux.
Dimensions du produit
G
F
E
D
C
B
A
A. 12 7/16 po (31,6cm)
B. 12 11/16 po (32cm)
C. 29 15/16 po (76cm)
35 6/16 po (89,6cm)
D. 17 1/16 po (43,4cm)
E. 2 6/16 po (6,0cm)
F. 26 12/16 po (67,9cm)
G. **27 15/16 po (71,0cm)
minimum
***47 4/16 po (120,0cm)
maximum
*Installations avec décharge à l’extérieur uniquement
**Installation sans décharge à l’extérieur (recyclage) uniquement
Dimensions d’installation
11 13/16 po (30cm) minimum
12 10/16 po (32cm) minimum
3 12/16po (9,5cm) 1 10/16po (4,2cm)
11 13/16 po (30 cm) minimum
12 10/16 po (32 cm) minimum
19 2/16po (48,5cm)
30po (76,2cm)
36po (91,4 cm)
Armoire latérale Armoire
latérale
Distance « X » entre
bas d’auvent et
surface de cuisson Axe central
Surface de cuisson
Emplacement
du point
d’entrée
du conduit
d’évacuation
et du cordon
d’alimentation
*Installations sans décharge à l’extérieur (recyclage)
IMPORTANT:
Valeur minimale de la distance « X »: 30po (76,2cm) à partir de la
surface de cuisson électrique.
Distance minimale de 30po (76,2cm) à partir des surfaces de
cuisson au gaz.
Valeur maximale suggérée pour la distance « X »: 36po (91,4cm)
Installations avec évacuation à l’extérieur
Hauteur minimale
sous plafond Hauteur maximale
sous plafond
Surface de
cuisson électrique 7pi 10po (2,39m) 10pi 4po (3,24m)
Surface de
cuisson à gaz 8pi 4po (2,54m) 10pi 4po (3,24 m)
Installations sans évacuation à l’extérieur (recyclage)
Hauteur minimale
sous plafond Hauteur maximale
sous plafond
Surface de
cuisson électrique 7pi 10po (2,39 m) 10pi 4po (3,24 m)
Surface de
cuisson à gaz 8pi 4po (2,54 m) 10pi 4po (3,24 m)
*REMARQUE: Les cheminées de hotte sont réglables; on peut
les placer en fonction de la hauteur disponible du plafond ou
soffite, et selon la distance « C » entre le bas de la hotte et la
surface de cuisson. Pour des plafonds de hauteur supérieure, un
ensemble d’extension de cache-conduit en acier inoxydable peut
être acheté, en se référant au numéro de pièce, auprès de votre
revendeur ou d’un distributeur de pièces autorisé. L’extension
de cache-conduit remplace la section supérieure de cheminée
fournie avec la hotte.
Exigences concernant
l’évacuation
Le circuit d’évacuation doit décharger l’air à l’extérieur, excepté
pour les installations sans décharge à l’extérieur (recyclage).
Ne pas terminer le circuit d’évacuation dans un grenier ou dans
un autre espace clos.
Ne pas utiliser de bouches de décharge murale de 4po
(10,2cm) normalement utilisées pour un équipement de
buanderie.
Utiliser un conduit métallique uniquement. Un conduit en métal
rigide est recommandé. Ne pas utiliser de conduit de plastique
ou de métal très mince.
Le circuit d’évacuation doit comporter un clapet anti-reflux. Si
la bouche de décharge murale ou par le toit comporte un clapet
anti-reflux, ne pas utiliser le clapet fourni avec la hotte.
Pour un fonctionnement efficace et silencieux:
Utiliser autant que possible des sections droites et réduire le
nombre de coudes.
Ne pas utiliser plus de trois coudes à 90°.
Veiller à incorporer une section de conduit rectiligne d’au moins
24po (61,0cm) si plus d’un raccord coudé est utilisé.
Ne pas installer 2 coudes ensemble.
Pour assurer l’étanchéité de toutes les jonctions du circuit
d’évacuation, utiliser des brides pour conduit.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité autour
de la bouche de décharge à l’extérieur (à travers le mur ou le
toit).
La taille du conduit doit être uniforme.
20
Installations dans les régions au climat froid
Un clapet anti-reflux additionnel devrait être installé pour
minimiser le reflux d’air froid et une barrière thermique
devrait aussi être installée pour minimiser la conduction
des températures extérieures par l’intermédiaire du conduit
d’évacuation. Le clapet anti-reflux doit être placé du côté air froid
de la barrière thermique.
La barrière thermique doit être aussi proche que possible de
l’entrée du circuit d’évacuation dans la partie chauffée de la
maison.
Air de compensation
Les codes locaux en bâtiment peuvent imposer l’emploi
d’un circuit de renouvellement de l’air/introduction d’air de
compensation, lors de l’utilisation d’un circuit d’aspiration de
débit supérieur à une valeur spécifiée en pieds cubes par minute
(CFM). Le débit spécifié en pieds cubes par minute varie d’une
juridiction à l’autre.
Consulter un professionnel des installations de chauffage
ventilation/climatisation au sujet des exigences spécifiques
applicables dans la juridiction locale.
Méthodes d’évacuation
Pour l’installation, on doit utiliser un conduit d’un diamètre de
6po (15,2cm) (non fourni). La hotte comporte une ouverture de
sortie d’un diamètre de 6po (15,2cm).
REMARQUE: L’emploi d’un conduit flexible est déconseillé.
Un conduit flexible peut causer une contre-pression et des
turbulences d’air, qui réduisent considérablement la performance.
La sortie à l’extérieur du circuit d’évacuation peut se faire à
travers le toit ou le mur
Pour la sortie à travers le mur, on doit employer un raccord coudé
à 90°.
Installations sans décharge à l’extérieur (recyclage)
S’il n’est pas possible d’évacuer les fumées et vapeurs de
cuisson à l’extérieur, on peut employer la version d’installation
sans décharge à l’extérieur (recyclage) de la hotte, ainsi dotée
d’un filtre au charbon et du déflecteur. Les vapeurs/fumées sont
alors recyclées à travers la grille supérieure.
Évacuation Décharge à Sans décharge à
par le toit travers le mur l’extérieur
(recyclage)
A. Bouche de
décharge sur toit
B. Conduit métallique
rond, dia. 6po
(15,2cm)
A. Bouche de
décharge murale
B. Conduit métallique
rond, dia. 6po
(15,2cm)
A. Déflecteur
B. Conduit métallique
rond, dia. 6po
(15,2cm)
Calcul de la longueur du circuit d’évacuation
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds ou
mètres) de tous les composants utilisés dans le circuit.
Composant Conduit rond de 6po (15,2cm)
Coude de 45° 2,5pi (0,8m)
Coude de 90° 5,0pi (1,5m)
La longueur équivalente maximale est de 35pi (10,7m).
Exemple de circuit d’évacuation
Coude à 90°
Bouche de
décharge
murale
6pi(1,8m)
2pi
(0,6m)
Dans l’exemple suivant, la longueur théorique du circuit est
inférieure au maximum de 35pi (10,7m).
1 coude de 90° = 5pi (1,5m)
1 bouche de décharge murale = 0pi (0m)
Section droite de 8pi (2,4m) = 8pi (2,4m)
Longueur du circuit = 13pi (3,9m)
Spécifications électriques
Observer les dispositions de tous les codes et règlements en
vigueur.
S’assurer que l’installation électrique est appropriée et conforme
au National Electrical Code, à la norme ANSI/NFPA70 (plus
récente édition) ou à la norme CSAC22.1-94, au Code canadien
de l’électricité, partie1 et C22.2 No0-M91 (plus récente édition)
et à tous les codes et règlements locaux.
Si les codes le permettent et si on utilise un conducteur distinct
de mise à la terre, il est recommandé qu’un électricien qualifié
vérifie la qualité de la mise à la terre.
INSTRUCTIONS DE LIAISON À LA TERRE
Si les codes le permettent et si on utilise un conducteur distinct
de mise à la terre, il est recommandé qu’un électricien qualifié
vérifie la qualité de la mise à la terre.
Ne pas utiliser une tuyauterie de gaz pour le raccordement à la
terre.
En cas de doute quant à la qualité de la liaison à la terre de la
hotte, consulter un électricien qualifié.
Ne pas installer un fusible dans le conducteur neutre ou le circuit
de mise à la terre.
Consulter un électricien qualifié si les instructions de mise à la
terre n’ont pas été bien comprises, ou en cas de doute sur la
qualité de la liaison à la terre de l’appareil.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Jenn-Air JVW0330LS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues