Jenn-Air JXW8936DS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

Ce manuel convient également à

JENN-AIR
®
36" (91.4 CM) WALL-MOUNT
CANOPY RANGE HOOD
HOTTE DE CUISINIÈRE JENN-AIR
®
POUR
MONTAGE MURAL 36" (91,4 CM)
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.ca.
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composez le 1-800-JENNAIR (1-800-536-6247) ou visitez notre site web
à www.jennair.ca.
Table of Contents/Table des matières .....................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONL
Y.
IMPOR
TANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISA
TION RÉSIDENTIELLE UNIQUEMENT
.
2843/W10640311D
2
TABLE OF CONTENTS TABLE DES MATIÈRES
RANGE HOOD SAFETY .................................................................3
INSTALLATION REQUIREMENTS ................................................. 5
Tools and Parts .............................................................................5
Location Requirements ................................................................5
Venting Requirements ..................................................................6
Electrical Requirements ...............................................................7
INSTALLATION INSTRUCTIONS ................................................... 9
Prepare Location ..........................................................................9
Install Range Hood .....................................................................11
Connect Vent System ................................................................11
Reinstall Motor ...........................................................................12
Make Electrical Connection .......................................................12
Install Chimney Covers ..............................................................13
Complete Installation .................................................................14
RANGE HOOD USE ......................................................................14
Controls and Features ................................................................ 14
RANGE HOOD CARE ...................................................................15
Cleaning .....................................................................................15
WIRING DIAGRAM .......................................................................17
ASSISTANCE OR SERVICE .........................................................18
In the U.S.A. ..............................................................................18
In Canada ...................................................................................18
Accessories ................................................................................18
WARRANTY ..................................................................................19
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE ...............................20
EXIGENCES D’INSTALLATION ...................................................22
Outils et pièces ...........................................................................22
Exigences d’emplacement .........................................................22
Exigences concernant l’évacuation ...........................................23
Spécifications électriques ..........................................................25
INSTRUCTIONS D’INSTALLATION .............................................27
Préparation de l’emplacement ...................................................27
Installation de la hotte ................................................................29
Raccordement du circuit d’évacuation ...................................... 29
Remontage du moteur ...............................................................30
Raccordement électrique ...........................................................30
Installer les cache-conduits .......................................................31
Achever l’installation ..................................................................32
UTILISATION DE LA HOTTE .......................................................32
Commandes et caractéristiques ................................................32
ENTRETIEN DE LA HOTTE .........................................................34
Nettoyage ...................................................................................34
SCHÉMA DE CÂBLAGE ...............................................................36
ASSISTANCE OU SERVICE .........................................................37
Au Canada ..................................................................................37
Accessoires ................................................................................37
GARANTIE .....................................................................................38
3
RANGE HOOD SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
4
IMPORTA NT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
5
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed:
Level
Drill with 1
1
/
4
" (3.0 cm) and
3
/
16
" (5.0 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
TORX
®†
T20
®†
bit or driver
Parts needed:
For hard wire installations, you will also need:
Home power supply cable
1
/
2
" (12.7 mm) UL listed or CSA approved strain relief
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will
also need:
Chimney Kit Recirculation for non-vented (recirculating)
installations only. See the “Assistance or Service” section
to order.
Charcoal Filter Kit Part Number W10272069.
See “Assistance or Service” section to order.
Parts supplied:
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and lights installed
Vent mounting boss (attached to hood canopy assembly)
Damper
3 - 3.5 x 9.5 mm screws damper to mounting boss
Metal grease filter installed in hood canopy
Chimney cover support bracket
2-piece chimney cover
2 - 8 x 80 mm hanger bolts (T20
®
TORX
®
drive)
2 - 8 mm nuts
2 - flat washers
2 - 5 x 40 mm Torx
®
T20
®
drive screws for chimney
bracket mounting.
2 - 5 mm wall anchors
1
/
2
" (13 mm) special nut tightening tool
2 - plastic spacers for lower chimney
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall of
the vent hood.
Canopy hood location should be away from strong draft
areas, such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
The canopy hood mounting location must be capable
of supporting 100 lbs (45.4 kg).
This range hood is recommended for use with cooktops
with a maximum total rating of 78,000 Btus or less.
Grounded electrical outlet is required. See the “Electrical
Requirements” section.
For non-vented (recirculating) Installation see “Non-vented
(recirculating) Installations” in the “Install Range Hood” section.
Chimney Kit Recirculation and Charcoal Filter Kit Part Number
W10272069 are available from your dealer or an authorized parts
distributor. See the “Assistance or Service” section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations:
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A or latest edition, or
with local codes.
Product Dimensions
G
F
E
D
C
B
A
A. 12
3
/
8
" (31.4 cm)
B. 13
1
/
8
" (33.4 cm)
C. 36" (91.4 cm)
D. 21
9
/
16
" (54.8 cm)
E. 1
5
/
8
" (4.2 cm)
F. 25
9
/
16
" (65.0 cm)
G. 33
1
/
8
" (84.1 cm) min.
54
3
/
4
" (139.1 cm) max.
TORX and †®T20 are registered trademarks of Acument Intellectual Properties, LLC.
6
Cabinet Dimensions
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric
cooking surface
Minimum distance “X”: 30" (76.2 cm) from gas
cooking surface
Suggested maximum distance “X”: 36" (91.4 cm)
NOTE: For best performance of the Auto Sense feature, the
range hood should be installed at 24" (61.0 cm) from an electric
cooking surface and 30" (76.2 cm) from a gas cooking surface.
The chimneys can be adjusted for different ceiling heights.
See the following chart.
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance “X” between the bottom of the range hood and
the cooking surface. For higher ceilings from 10' 4" to 12’
(3.24 m to 3.66 m), a Stainless Steel Chimney Extension Kit
is available from your dealer or an authorized parts distributor.
The chimney extension replaces the upper chimney shipped
with the range hood. See the “Assistance or Service” section to
order.
Venting Requirements
(vented models only)
Vent system must terminate to the outdoors, except for
non-vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with
the range hood.
Use caulking to seal exterior wall or roof opening around
the cap.
The size of the vent should be uniform.
Cold Weather Installations:
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air:
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting Methods
This canopy hood is factory set for venting through the roof
or wall.
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
A 6" to 8" (15.2 cm to 20.3 cm) vent adapter is available for 8"
(20.3 cm) vent systems. See the “Assistance or Service” section
to order.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear discharge:
A 90° elbow may be installed immediately above the hood.
10" (25.4 cm) min.
13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
2" (5.1 cm) min.
9" (22.9 cm) min.*
Centerline
Side
cabinet
Side
cabinet
Vent and po
wer
supply cable
entry location
20³⁄₈" (51.8 cm)*
36" (91.4 cm)
“X”
bottom of
canopy
to cooking
surface
10" (25.4 cm) min.
13" (33.0 cm) max.
Cooking surface
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 10" (2.39 m) 10' 4" (3.24 m)
Gas cooking
surface
8' 4" (2.54 m) 10' 4" (3.24 m)
Non-Vented (Recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 10" (2.39 m) 10' 4" (3.24 m)
Gas cooking
surface
8' 4" (2.54 m) 10' 4" (3.24 m)
7
For Non-Vented (recirculating) Installations:
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, fitting a charcoal filter and the deflector. Fumes and
vapors are recycled through the upper chimney cover louvers.
To order the charcoal filter and recirculation kit, see
“Accessories” in the “Assistance and Service” section.
Roof Venting
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deflector
B. 6" (15.2 cm)
round vent
Wall Venting
Non-Vented
(recirculating)
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Maximum equivalent vent length is 35 ft (10.7 m).
Example vent system:
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120-volt, 60 Hz., AC-only, 15-amp, fused electrical circuit
is required.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
8
For 3 Prong Grounded Power Cord:
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
This range hood is equipped with a power supply cord
having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances.
If a mating outlet is not available, it is the responsibility of
the customer to have the properly grounded outlet installed
by a qualified electrician.
The grounded 3 prong outlet is to be located above the
range hood at a maximum distance of 40" (101.6 cm) from
where the power cord exits the hood. See illustration.
40"
(101.6 cm)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For a grounded, cord-connected range hood:
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
For Hard Wire from Home Power Supply:
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the
pigtail leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the filter on
the rear wall of the range hood.
Wire sizes must conform to the requirements of the
National Electrical Code, ANSI/NFPA 70 (latest edition),
or CSA Standards C22. 1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
9
INSTALLATION INSTRUCTIONS
Prepare Location
It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall,
or non-vented.
3. Select a flat surface for assembling the range hood.
Place covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto
covered surface.
5. Remove the motor from the canopy assembly (see the
“Motor Removal” section in this section).
Motor Removal
To remove motor:
1. Remove the filter cover and metal grease filter (see the
“Metal Grease Filters” section in the “Range Hood Care”
section).
2. Disconnect the blower motor wiring at the 9-pin connector.
3. Locate the special
1
/
2
" (13 mm) tool inside the range hood
blower housing in the left front corner behind the insulation
pad. Use it to loosen the 4 nuts located inside the blower
housing that mounts the motor to the module top cover.
4. Grasp the motor plate and slide the motor toward the
back of the module housing to the large openings in the
keyhole slots.
B
F
E
D
C
A
A. Special
1
/
2
" (13 mm) tool
B. Motor assembly
C. Keyhole slots (large opening) (4)
D.
1
/
2
" (13 mm) motor mounting nuts (4)
E. Motor plate
F. Module top cover
5. Remove the motor from the range hood.
A
B
D
C
A. Blower housing
B. Keyhole slots (4)
C. Motor assembly
D. Motor plate
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where the
canopy hood will be installed.
2. Select a mounting height between a minimum of 24"
(61.0 cm) for an electric cooking surface, a minimum of
30" (76.2 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a horizontal reference line on the wall.
3. Measure up from the horizontal mounting height reference
line 21
15
/
16
" (55.7 cm) and draw a parallel horizontal line.
Measure from the centerline 4
5
/
8
" (11.8 cm) in each direction
along the upper horizontal line. Mark the centers for the
fastener locations.
A
C
B
B
21¹⁵⁄₁₆" (55.7 cm)
4⁵⁄₈"
(11.8 cm)
4⁵⁄₈"
(11.8 cm)
A. Centerline
B. Fastener locations
C. Mounting height reference
(hood bottom line)
IMPORTANT: All screws must be installed into wall wooden
support structure. If there is no wooden support structure
to screw into, additional wall framing supports will be
required. This mounting structure must be capable of
supporting 100 lbs (45.4 kg).
4. Drill
3
/
16
" (4.8 mm) pilot holes at all locations where screws
are being installed into wood.
10
5. Using a TORX
®
T20
®
bit and driver, install the 2 - 8 x 80 mm
hanger bolts. Leave a 1
1
/
4
" (31.8 mm) gap between the wall
and the end of the hanger bolt for sliding the range hood into
place.
1¹⁄₄
"
(3.18 cm)
Vent Cover Bracket Installation
1. Use chimney cover mounting bracket centered on the
centerline of the wall and flush to the ceiling to mark the
center points of the outermost holes for mounting screws.
Mark and drill 2 -
3
/
16
" (4.8 mm) holes.
2. Install the 5 mm wall anchors.
For Vented Installations Only:
1. Attach the chimney cover bracket to the wall using
2 - 5 x 40 mm screws (D).
A
C
B
D
A. Ceiling
B. Wall
C. Centerline
D. 5 x 40 mm screws (2)
For Non-Vented (recirculating) Installations Only:
1. Attach the chimney cover bracket and air deflector bracket
to the wall using the (2) 5 x 40 mm screws (D).
A. Ceiling
B. Wall
C. Centerline for range hood
A
F
B
D
E
C
2. Install the 5 x 40 mm screw through the top of the air
deflector bracket into the ceiling.
NOTE: To use the optional 5 mm wall anchor supplied with
the recirculation kit in the ceiling, locate and mark the hole
through the top of the air deflector bracket. Remove the
bracket and drill a
3
/
16
" (4.8 mm) hole and install the 5 mm
wall anchor.
A. Ceiling
B. Wall
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See the “Venting Requirements” section.
For Vented Installations Only:
Using a jigsaw or keyhole saw, cut a 6
1
/
2
" (16.5 cm) diameter
hole in the wall or ceiling for the vent duct.
Install the vent duct system through the hole.
Seal all connections with vent clamps.
For Use with Grounded Power Supply Cord:
This range hood is equipped with a power supply cord
having a 3 prong grounding plug.
A 3 prong receptacle is required to be located at a maximum
distance of 40" (101.6 cm) above the range hood terminal
box. If a mating outlet is not available, it is the responsibility
of the customer to have a properly grounded outlet installed
by a qualified electrician.
For Use with a Hard Wire Home Power Supply Cable:
Determine the required height for the home power supply
cable and drill a 1
1
/
4
" (3.2 cm) hole at this location.
Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough
1
/
2
" conduit and wires
from the fused disconnect (or circuit breaker) box to make
the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
2. Use caulk to seal all openings.
A
B
C
D
D. 5 x 40 mm screws (2)
E. Air deflector bracket
F. Chimney cover bracket
C. Air deflector bracket
D. 5 x 40 mm screw
11
Install Range Hood
1. Using 2 or more people, hang range hood on the 2 mounting
screws through the mounting slots on the back of the hood.
A
B
C
A. Mounting hanger bolts
B. Mounting slots
C. Flat washers and nuts
2. Install the flat washers and nuts to the hanger bolts. Level
the range hood and tighten the nuts.
Connect Vent System
For Vented Installations:
1. Assemble the damper (if needed) to the mounting boss using
(3) 3.5 x 9.5 mm screws.
2. Assemble the vent system to the damper (if used) or the
mounting boss.
A. Metal duct
B. Vent clamps
C. Mounting boss
3. Secure all of the connections with vent clamps.
4. Check that the backdraft damper (if used) works properly.
A
B
C
B
A
B
C
Front of range hood
A
B
C
D
Parallel
For Non-Vented (recirculating) Installations:
1. Mount the air deflector and flexible duct assembly to the air
deflector bracket using (4) 3.5 x 9.5 mm screws supplied
with the Recirculation Kit.
A. Air deflector bracket
B. Air deflector/flexible duct assembly
C. 3.5 x 9.5 mm screws (4)
2. Loosen the 4 nuts on the mounting boss. The back flange of
each nut should be approximately
3
/
16
" (5 mm) from the face
of the mounting boss.
3. Expand the flexible section of vent duct to the top of the
range hood top plate.
4. Check the mounting boss handle for alignment. The
mounting boss handle must align parallel with the front
of the range. If alignment is needed, loosen one of the
vent clamps and adjust as necessary. Retighten any vent
clamps that are loosened.
5. Secure all of the connections with vent clamps.
6. Reach inside the range hood cavity and grasp the handle
of the mounting boss. Pull down to align the nuts through
the cut-out holes in the module top cover. Push back into
the half-slots to assemble. Tighten the 4 nuts using the
1
/
2
" (13 mm) special tool or
1
/
2
" (13 mm) socket and driver
with extension.
A. Inside of range hood cavity
B. Mounting boss handle
C. Half slots in module top cover (4)
D. Nuts (4)
NOTE: For ceiling heights above 9 ft (1.8 m), an appropriate
length of 6" (15.2 cm) ducting (not supplied) will be required.
12
Reinstall Motor
1. Place the motor into the module housing, positioning it with
the large keyholes in motor mounting plate towards the back
of the canopy.
2. Grasping the motor plate, push the motor up into the module
housing. Locate the large keyholes over the motor mounting
nuts, push up against the module top cover, and pull the
motor forward to lock into the small keyholes slots.
3. Use the special
1
/
2
" (13 mm) tool and tighten the 4 nuts to
secure the motor.
Make Electrical Connection
For 3 Prong Grounded Power Cord:
1. Plug 3 prong power cord into a grounded 3 prong outlet
located above the range hood.
For Hard Wire from Home Power Supply:
1. Disconnect power.
2. Remove the terminal box cover.
3. Disconnect grounded power cord wires from terminal block.
Loosen the screws labeled “L,” “N,” and “Ground Symbol.”
4. Remove power cord strain relief from terminal box and
remove power cord.
A. Power cord
B. Power cord strain relief
C. Location “L” (black wire)
D. Location “N” (white wire)
E. Location ground symbol (green or bare ground wire)
5. Install a UL listed or CSA approved
1
/
2
" strain relief.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
40"
(101.6 cm)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
D
A
B
C
E
A. Screws
B. Terminal box cover
13
6. Run the home power supply cable through the strain relief,
into the terminal box.
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Location “L” (black wire)
D. Location “N” (white wire)
E. Location ground symbol (green or bare ground wire)
7. Loosen the screw labeled “L” on the terminal block and
connect black wire C. Retighten the screw.
8. Loosen the screw labeled “N” on the terminal block and
connect white wire D. Retighten the screw.
9. Loosen the screw labeled with the “Ground Symbol” on the
terminal block and connect green (or bare) ground wire E.
Tighten the screw.
10. Tighten the strain relief screws.
11. Reinstall the terminal box cover.
12. Reconnect power.
Install Chimney Covers
1. On the upper chimney cover, bend out tabs (2) approximately
1
/
8
" (3 mm).
2. Slide rear flanges of upper chimney cover between catch
tabs on chimney cover mounting bracket and lock bent-
out tabs into slots in the back plate of the chimney cover
mounting bracket.
NOTE: Once the upper chimney cover tabs are locked into
the chimney cover mounting bracket, the upper chimney
cover will be hard to remove. If removal is required, place a
thin blade behind the top corner of the upper chimney cover
and the chimney cover mounting bracket to push in the
catch tabs on both sides and pull the rear side flange out
of the chimney cover mounting bracket.
3. Attach the 2 plastic spacers (F), one on each side at the
bottom of the blower module.
4. Widen the lower chimney cover and slide it over the upper
chimney cover and blower module. The lower chimney cover
must rest on the top of the hood.
A. Ceiling
B. Chimney cover mounting bracket
C. Upper chimney cover - rear flanges
D. Upper chimney cover
E. Lower chimney cover
F. Plastic spacers (2)
D
A
B
C
E
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
¹⁄₈"
(3 mm)
B
A
D
E
C
F
14
Complete Installation
1. For non-vented (recirculating) installations only, install the
charcoal filters over the metal mesh filter. See the “Range
Hood Care” section.
2. Install the metal filter. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and lights.
See the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range
hood, read the “Range Hood Use” section.
The range hood is designed to remove smoke, cooking vapors,
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen.
The range hood controls are located on the front of the canopy.
A. Louver holes (non-vented
[recirculating] installations only)
B. Chimney covers
C. Lamps
D. Filter door glass
E. Canopy glass
F. Canopy
G. Control panel
Control Panel
RANGE HOOD USE
Controls and Features
NOTES:
To activate the controls, press and release the desired
button.
The control feature button will be lit when a control feature
is turned on.
Sleep Mode
The range hood automatically enters Sleep mode when not in
use. After 10 minutes of no range hood activity, all of the control
button lights will turn off. To deactivate Sleep mode, press any
button.
Auto Sense
Auto Sense allows the range hood fan to turn on automatically
when it senses heat higher than its allowable temperature limit.
When Auto Sense is ON, the fan speed will increase or decrease
based on the temperature Auto Sense is measuring.
Auto Sense can be manually increased by pressing a higher fan
speed. The fan will run at the selected speed for 10 minutes
before returning to the speed selected for Auto Sense.
If Auto Sense is ON, the Auto button light will turn off and go into
Sleep Mode when the vent hood is not in use. If the vent hood is
turned ON by the consumer or by Auto Sense, the Auto button
light will turn ON.
To Set Auto Sense:
Press AUTO.
To Select Auto Sense Cooktop Type:
NOTE: The range hood is factory set for the gas cooktop
mode.
Press and hold AUTO for 5 seconds to switch between the
gas cooktop and electric cooktop modes.
The Auto button light will flash 5 times when the range hood
is changed to the electric cooktop mode. Auto Sense is now
set to work with electric cooktops and ranges.
The Auto button light will flash 3 times when the range hood
is changed to the gas cooktop mode. Auto Sense is now set
to work with gas cooktops and ranges.
Changing the cooktop type will change the temperature limit
for Auto Sense to turn ON. When the range hood senses a
high enough temperature, the fan will start automatically.
When the temperature drops below the set temperature limit,
the fan will stop automatically. The Auto button light will turn
off after the range hood enters Sleep mode, but Auto Sense
is still active.
To Deactivate Auto Sense:
If the Auto button is lit, press AUTO once to deactivate
Auto Sense. The Auto button light will turn off.
If Auto Sense is in Sleep mode, press AUTO once to
deactivate Sleep mode and turn the Auto button light on.
Press AUTO again to deactivate Auto Sense and turn off
the Auto button light.
Auto Sense will automatically turn off after 2 hours of no
activation of the Auto Sense system. To reset Auto Sense,
press AUTO.
Manual Vent Functions
A
C
D
E
F
G
B
Auto Low
Med
Hi Boost Filter Light
Fan Speeds
Low
Press LOW to turn the fan on at Low speed.
Med
Press MED to turn the fan on at Medium speed.
Hi
Press HI to turn the fan on at High speed.
Boost
Press BOOST to turn the fan on at the
highest speed. Boost will automatically turn
off after 10 minutes and the fan will switch
to High speed.
15
Timer
The range hood can be set to automatically turn off after
15 minutes.
1. Press and hold the desired fan speed button for 2 seconds.
The fan will run on the chosen speed for 15 minutes and the
fan speed button light will flash continuously.
After 15 minutes, the fan will turn off automatically.
2. Press the desired fan speed button again while the fan timer
is running to cancel the fan timer.
NOTE: Changing the fan speed or turning Auto Sense on will
also cancel the 15-minute timer.
Filter
The Filter button lights up when it is time to replace or clean the
filter. The button will be lit only when the fan is on. Press FILTER
after replacing the filter to turn the Filter button light off. See the
“Cleaning” section for how to replace or clean the filter.
Light
Press LIGHT to turn the range hood lights on and off.
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool
or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser:
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filters
The filter should be washed frequently. Place the metal filter in
the dishwasher or hot detergent solution to clean.
Let the filter dry thoroughly before replacing it.
NOTE: The metal grease filter is located behind the center glass
panel. The panel is hinged on the left side and magnetically
secured on the right side. To access the grease filter, grasp the
panel on the right-hand corners and pull down. This releases the
panel from the magnets and allows the panel to swing down.
A. Slot for filter cover alignment
B. Filter cover magnets
C. Filter cover
D. Tab on filter cover for alignment
A
B
16
To Remove Metal Grease Filters:
1. Turn off fan and lights.
2. Remove the filter holder frame and grease filter using a flat-
blade screwdriver to turn the grease filter release screws 90°
counterclockwise.
A. Grease filter release screw
B. Filter holder frame
C. Grease filter
To Replace Metal Grease Filter:
Replace grease filter and filter holder frame into range hood.
Align the grease filter release screw and use a flat-blade
screwdriver to turn the grease filter release screws 90°
clockwise to lock in place.
Charcoal Filters - For Non-Vented (recirculating)
Installations
NOTE: After approximately 3 years of use the charcoal filter
should be replaced. To order a replacement Charcoal Filter Kit,
see the “Assistance or Service” section.
The charcoal filters can be cleaned and reactivated. Clean the
filter in the dishwasher using normal detergent and choosing the
highest temperature setting.
To reactivate the filter, the filter should be dried in an oven for
10 minutes with a maximum temperature of 210°F (100°C).
To Remove Charcoal Filters:
1. Turn fan and lights off.
2. Remove the metal grease filters. See the “Metal Grease
Filters” section.
3. Remove the upper and side lock springs.
4. Clean or discard the charcoal filter.
To Replace Charcoal Filters:
1. For non-vented (recirculating installations) install charcoal
filter, wrapping it around the grease filter.
2. Place the charcoal filter mat around the grease filter and fix it
in place by using the cap lock springs provided.
3. Position the upper cap and fix it in place using the cap lock
spring provided.
A. Charcoal filter mat
B. Grease filter
C. Charcoal filter side lock springs
D. Upper cap
E. Cap lock spring
F. Grease filter support
C
B
A
17
WIRING DIAGRAM
SEL0093237
23
1
23
1
4 23
1
4
1
2
3
4
5
66 6 6
7
8
M
9
Power
Connections
Additional lamp only
in 4 lamps version
Fuse
RL2
RL4
RL1
FT1
FT2
FT6 FT4
FT5FT3
L
N
1
BK
BK
BK
BK - 1
BK
BK
YL/
GN
YL/
GN
WH
WH
WH
WH - 2
YL
BR
BK - 3
BR
BR
BU
WH -
BU - 5
BU
BU
RD
RD - 4
RD
RD
GY
GY - 3
Motor Specifications
3.7 A
120 VAC
Blue - Red
Blue - Black
Frequency
Power Supply
Wattage Rating
14.90 Ohm
9.92 Ohm
22.00 Ohm
Amperage
Motor Speed/Resistance
18.40 Ohm
420 W
Blue - Gray
60 Hz
Blue - White
Component Layout
Description
Num.
E.M.I. Filter
User Interface
Main Board
Light Driver
Capacitor
LED Lamp
6
5
4
3
2
1
L
N
C
1
3
2
4
Temperature Sensor
Surge Protector
Motor
9
8
7
BK
YL/
GN
WH
YL
BR
BU
RD
GY
BK
YL/
GN
WH
YL
BR
BU
RD
GY
BK
BU
RD
BU
2 Speed
4 Speed
3 Speed
1 Speed
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
Not
used
Not
used
12 VDC
12 VDC12 VDC
12 VDC
12
VDC
18
ASSISTANCE OR SERVICE
If you need service:
Please refer to the warranty page in this manual.
If you need replacement parts:
If you need to order replacement parts, we recommend that
you use only factory specified parts. Factory specified parts
will fit right and work right because they are made with the
same precision used to build every new appliance.
To locate factory specified replacement parts in your area, call
the following customer assistance telephone number or your
nearest designated service center.
In the U.S.A.
Call Jenn-Air Customer eXperience Center toll free:
1-800-JENNAIR (1-800-536-6247) or visit our website
at www.jennair.com.
Our consultants provide assistance with:
Scheduling of service. Jenn-Air
®
appliances designated
service technicians are trained to fulfill the product
warranty and provide after-warranty service anywhere
in the United States.
Features and specifications on our full line of appliances.
Referrals to local Jenn-Air
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
For further assistance:
If you need further assistance, you can write to Jenn-Air
®
Appliances with any questions or concerns at:
Jenn-Air Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
In Canada
Call the Whirlpool Canada LP Customer eXperience Centre toll
free at 1-800-JENNAIR (1-800-536-6247) or visit our website at
www.jennair.ca.
Our consultants provide assistance with:
Scheduling of service. Jenn-Air
®
appliances designated
service technicians are trained to fulfill the product warranty
and provide after-warranty service anywhere in Canada.
Features and specifications on our full line of appliances.
Referrals to local Jenn-Air
®
appliance dealers.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
For further assistance:
If you need further assistance, you can write to Jenn-Air
®
Appliances with any questions or concerns at:
Jenn-Air Brand Home Appliances
Customer eXperience Centre
200 - 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Charcoal Filter Kit
(for non-vented installations only)
Order Part Number W10272069
Chimney Extension Kit (vented)
(for 9' 6" to 12' [2.89 m to 3.66 m] ceilings)
Order Part Number W10646864
Chimney Kit Recirculation
(for 7' 9" to 10' 4" [2.36 m to 3.15 m] ceilings)
(for non-vented installations)
Order Part Number W10685949
Chimney Extension Kit (recirculating)
(for 9' 6" to 12' [2.89 m to 3.66 m] ceilings)
(for non-vented installations)
Order Part Number W10686362
6" (15.2 cm) Makeup Air Kit
(consult local building codes)
Order Part Number W10446915
Vent Duct Adapter 6" to 8" (15.2 cm to 20.3 cm)
(for 8" [20.3 cm] duct installations)
Order Part Number W10685950
19
12/14
IF YOU NEED SERVICE:
1. Before contacting us to arrange service, please determine whether your product requires repair. Some
questions can be addressed without service. Please take a few minutes to review the Troubleshooting or
Problem Solver section of the Use and Care Guide, scan the QR code on the right to access additional
resources, or visit
https://jennair.custhelp.com.
2. All warranty service is provided exclusively by our authorized Jenn-Air Service Providers. In the U.S. and
Canada, direct all requests for warranty service to:
Jenn-Air Customer eXperience Center
1-800-JENNAIR (1-800-536-6247).
If outside the 50 United States or Canada, contact your authorized Jenn-Air dealer to determine whether another warranty applies.
JENN-AIR®
MAJOR APPLIANCE
LIMITED WARRANTY
ATTACH YOUR RECEIPT HERE. PROOF OF PURCHASE IS REQUIRED
TO OBTAIN WARRANTY SERVICE.
Please have the following information available when you call the
Customer eXperience Center:
Name, address and telephone number
Model number and serial number
A clear, detailed description of the problem
Proof of purchase including dealer or retailer name and address
TWO YEAR LIMITED WARRANTY
WHAT IS COVERED WHAT IS NOT COVERED
For two years from the date of
purchase, when this major appliance
is installed, operated and maintained
according to instructions attached to
or furnished with the product, Jenn-
Air brand of Whirlpool Corporation or
Whirlpool Canada LP (hereafter “Jenn-
Air”) will pay for Factory Specified
Replacement Parts and repair labor
to correct defects in materials or
workmanship that existed when this
major appliance was purchased, or at
its sole discretion replace the product.
In the event of product replacement,
your appliance will be warranted for
the remaining term of the original unit’s
warranty period.
YOUR SOLE AND EXCLUSIVE
REMEDY UNDER THIS LIMITED
WARRANTY SHALL BE PRODUCT
REPAIR AS PROVIDED HEREIN.
Service must be provided by a Jenn-
Air designated service company. This
limited warranty is valid only in the
United States or Canada and applies
only when the major appliance is
used in the country in which it was
purchased. This limited warranty is
effective from the date of original
consumer purchase. Proof of original
purchase date is required to obtain
service under this limited warranty.
1. Commercial, non-residential, multiple-family use, or use inconsistent with published user,
operator or installation instructions.
2. In-home instruction on how to use your product.
3. Service to correct improper product maintenance or installation, installation not in accordance
with electrical or plumbing codes or correction of household electrical or plumbing (i.e. house
wiring, fuses or water inlet hoses).
4. Consumable parts (i.e. light bulbs, batteries, air or water filters, preservation solutions, etc.).
5. Defects or damage caused by the use of non-genuine Jenn-Air parts or accessories.
6. Conversion of products from natural gas or L.P. gas.
7. Damage from accident, misuse, abuse, fire, floods, acts of God or use with products not
approved by Jenn-Air.
8. Repairs to parts or systems to correct product damage or defects caused by unauthorized
service, alteration or modification of the appliance.
9. Cosmetic damage including scratches, dents, chips, and other damage to the appliance
finishes unless such damage results from defects in materials and workmanship and is
reported to Jenn-Air within 30 days.
10. Discoloration, rust or oxidation of surfaces resulting from caustic or corrosive environments
including but not limited to high salt concentrations, high moisture or humidity or exposure to
chemicals.
11. Food or medicine loss due to product failure.
12. Pick-up or delivery. This product is intended for in-home repair.
13. Travel or transportation expenses for service in remote locations where an authorized Jenn-Air
servicer is not available.
14. Removal or reinstallation of inaccessible appliances or built-in fixtures (i.e. trim, decorative
panels, flooring, cabinetry, islands, countertops, drywall, etc.) that interfere with servicing,
removal or replacement of the product.
15. Service or parts for appliances with original model/serial numbers removed, altered or not
easily determined.
The cost of repair or replacement under these excluded circumstances shall be borne by
the customer.
DISCLAIMER OF IMPLIED WARRANTIES
IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. Some states and provinces do not
allow limitations on the duration of implied warranties of merchantability or fitness, so this limitation may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights that vary from state to state or province to province.
DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY
Jenn-Air makes no representations about the quality, durability, or need for service or repair of this major appliance other than the
representations contained in this warranty. If you want a longer or more comprehensive warranty than the limited warranty that comes with this
major appliance, you should ask Jenn-Air or your retailer about buying an extended warranty.
LIMITATION OF REMEDIES; EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN. JENN-
AIR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states and provinces do not allow the exclusion or
limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific
legal rights, and you also may have other rights that vary from state to state or province to province.
https://jennair.custhelp.com
20
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Avertissements de la proposition 65 de l'État de Californie :
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
cancers.
AVERTISSEMENT : Ce produit contient au moins un produit chimique connu par l’État de Californie pour être à l’origine de
malformations et autres déficiences de naissance.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Jenn-Air JXW8936DS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues