Briggs & Stratton 01677-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

Owner’s Manual
Manual del Propietario
Manuel de l'Utilisateur
Questions? Help is just a moment away!
Preguntas? La ayuda es justa un momento
lejos!
Vous avez des questions? Vous n'avez pas
besoin d'aller loin pour trouver de l'aide!
Call: Home Standby Helpline
Llamada: Línea Directa de Reserva de Hogar
Appelez: Ligne Directe de Secours À la Maison
- 1-800-746-4115 M-F 8-5 CT
Web: www.briggsandstratton.com
Part No. 190477GS Rev. 0 (02/26/02)
2
Briggs & Stratton Power Products Home Generator System
Owners Manual
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Product Specifications / Maintenance . . . . . . . . . . . . . . . 10
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Schematic / Wiring Diagram . . . . . . . . . . . . . . . . . . . 14-15
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . 16-19
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Last Page
EQUIPMENT
DESCRIPTION
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
This generator is an engine–driven, revolving field, alternating
current (AC) generator. It was designed to supply electrical
power for operating compatible electrical lighting, appliances,
tools and motor loads.The generator’s revolving field is
driven at about 3,600 rpm by a single-cylinder engine.
CAUTION! Do Not exceed the generator’s
wattage/amperage capacity. See “Don’t Overload the
Generator” on page 9.
Every effort has been made to ensure that information in this
manual is accurate and current. However, Briggs and Stratton
reserves the right to change, alter or otherwise improve the
product and this document at any time without prior notice.
The Emission Control System for this generator is warranted
for standards set by the Environmental Protection Agency. For
warranty information refer to the engine owner’s manual.
SAFETY RULES
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or serious
injury. WARNING indicates a hazard which, if not avoided,
could result in death or serious injury. CAUTION
indicates a hazard which, if not avoided, might result in
minor or moderate injury. CAUTION, when used
without the alert symbol, indicates a situation that could
result in equipment damage. Follow safety messages to
avoid or reduce the risk of injury or death.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Operate generator ONLY outdoors.
Keep at least 2 feet of clearance on all sides of generator for
adaquate ventilation.
Do not operate generator inside any building or enclosure,
including the generator compartment of a recreational vehicle
(RV).
Running generator gives off carbon monoxide,
an ordorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.
DANGER
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing gas cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
Do not overfill tank.Allow space for fuel expansion.
Keep gasoline away from sparks, open flames, pilot lights, heat,
and other ignition sources.
Do not light a cigarette or smoke.
WHEN OPERATING EQUIPMENT
Do not tip engine or equipment at angle which causes
gasoline to spill.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff
valve OFF.
Disconnect spark plug wire.
WHEN STORING GASOLINE OR EQUIPMENT WITH
FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite gasoline vapors.
Gasoline and its vapors are extremely flammable
and explosive.
Fire or explosion can cause severe burns or
death.
WARNING
3
Briggs & Stratton Power Products Home Generator System
Owners Manual
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
National Electric Code requires generator to be properly
grounded to an approved earth ground. Call an electrician for
local grounding requirements.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
Do not touch bare wires or receptacles.
Do not use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
Do not operate generator in the rain.
Do not handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
Do not allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to properly ground generator can result
in electrocution.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Do not allow any open flame, spark, heat, or lit cigarette
during and for several minutes after charging a battery.
Wear protective goggles, rubber apron, and rubber gloves.
Storage batteries give off explosive hydrogen gas
during recharging.
Hydrogen gas stays around battery for a long
time after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.
DANGER
Do not touch hot surfaces.
Allow equipment to cool before touching.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
WARNING
Do not tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
Do not modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
See “Don’t Overload Your Generator” on page 9.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generators wattage/amperage cappacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Use generator only for intended uses.
If you have questions about intended use, ask dealer or
contact Briggs and Stratton.
Operate generator only on level surfaces.
Do not expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
Do not insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
4
Briggs & Stratton Power Products Home Generator System
Owners Manual
Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-746-4115.
IMPORTANT: Any attempt to run the unit before it has
been serviced with the recommended oil will result in an
engine failure.
REMOVE GENERATOR
FROM CARTON
Set the carton on a rigid flat surface with “This Side Up”
arrows pointing upward.
Carefully open the top flaps of the shipping carton.
Cut down corners at one end of carton from top to
bottom and lay that side of carton down flat.
Remove all packing material, carton fillers, etc.
Remove the generator from the shipping carton.
Carton Contents
Check all contents. If any parts are missing or damaged, call
the home standby helpline at 1-800-746-4115.
5500 watt generator
Manual transfer switch
Wheel kit
Locking 30 Amp plug
Engine oil
Owner’s manual
Engine manual
Warranty sheet
Installation checklist
INSTALL WHEEL KIT
The wheel kit is designed to greatly improve the portability
of your generator.
NOTE: Wheel kit is not intended for over-the-road use.
You will need a socket wrench with 1/2" or 13mm sockets
and a needle-nose pliers to install this kit.
Refer to Figure 1 and install the wheel kit as
follows:
1. Place the generator on a hard flat surface.
2. Stand at the engine end of the generator and gently tilt
the generator forward, high enough to place wooden
blocks beneath the cradle.This will allow you to add
the wheels.
3. Slide the axle through the holes in the brackets
provided on the generator cradle.
4. Slide a wheel and flat washer on one end of the axle.
Make sure the air inflation valve is outward. Insert the
retaining pin.
Support Leg
Hex Nut
Axle
Flat Washer
Cap Screw
Handle Assembly
Hex Nut
Wheel
Retaining Pin
Figure 1 — Install Wheel Kit
Cap Screw
Hex Nut
Flat Washer
Cap Screw
Vibration Mount
Use existing hardware
to attach left side of
support leg to unit
5
Briggs & Stratton Power Products Home Generator System
Owners Manual
5. Slide the axle through until wheel is tight against
bracket.
6. Slide the other wheel and flat washer on the other end
of the axle. Make sure the air inflation valve is outward.
Insert the retaining pin using the needle-nose plier.
Remove the wooden blocks.
7. Attach the vibration mounts to the support leg with
30mm capscrews, washers and lock nuts.
8. To aid support leg assembly, rest generator on cradle,
engine end down. Remove the existing hardware from
the left unit vibration mount with 13mm wrench. Use
the same hardware to attach the support leg.
9. Attach the other side of the support leg with a 20mm
cap screw and lock nut. Rest generator on wheels and
support leg.
10. Center the handle bracket on generator frame at
support leg end of cradle, as shown.
11. Attach handle bracket with two M8 x 45mm cap
screws and two locking hex nuts.
12. Check each fastener to ensure it is secure and the
tires are inflated between 15-40 PSI.
BEFORE STARTING THE
ENGINE
Add Oil
CAUTION! Any attempt to crank or start the engine
before it has been properly filled with the recommended
oil may result in an engine failure.
To fill your engine with oil:
Place generator on a level surface.
Follow the oil grade recommendations and oil fill
instructions given in the engine owner’s manual.
NOTE: The generator’s revolving field rides on a
prelubricated and sealed ball bearing that requires no
additional lubrication for the life of the bearing.
Add Gasoline
WARNING! Never fill fuel tank indoors. Never
fill fuel tank when engine is running or hot.Allow unit
to cool for two minutes before refueling. Do Not
light a cigarette or smoke when filling the fuel tank.
WARNING! Do Not overfill the fuel tank.
Always allow room for fuel expansion.
Use regular UNLEADED gasoline with the generator
engine. Do Not use premium gasoline. Do Not mix oil
with gasoline.
Clean area around fuel fill cap, remove cap.
Slowly add unleaded regular gasoline to fuel tank. Be
careful not to overfill.Allow about 1.5" of tank space for
fuel expansion (Figure 2).
Install fuel cap and wipe up any spilled gasoline.
IMPORTANT: It is important to prevent gum deposits
from forming in essential fuel system parts, such as the
carburetor, fuel filter, fuel hose or tank during storage.Also,
experience indicates that alcohol–blended fuels (called
gasohol, ethanol or methanol) can attract moisture, which
leads to separation and formation of acids during storage.
Acidic fuel can damage the fuel system of an engine while in
storage.
To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. See “Storage”
on page 11. Never use engine or carburetor cleaner
products in the fuel tank or permanent damage may occur.
Figure 2 — Typical Fuel Expansion Space
Fuel
Tank
1.5” Airspace
6
Briggs & Stratton Power Products Home Generator System
Owners Manual
120 Volt AC, 20 Amp, Duplex Receptacles — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.
Air Cleaner — Uses a dry type filter element to limit the
amount of dirt and dust sucked into the engine.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Push to reset circuit breakers
are provided to protect the generator against electrical
overload.
Fuel Tank — Capacity of seven (7) U.S. gallons.
Grounding Wing Nut — Used for proper grounding of
unit.
Oil Fill Add engine oil here.
Recoil starter — Used to start the engine.
Rocker Switch — Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch off engine.
Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester screen.
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp
Duplex Receptacles
Fuel Tank
Choke Lever
Recoil Starter
Rocker Switch
(on engine shroud)
Circuit
Breakers (AC)
120/240 Volt AC,
30 Amp
Receptacle
Spark Arrester Muffler
Air Cleaner
Grounding Wing Nut
Oil Fill
7
Briggs & Stratton Power Products Home Generator System
Owners Manual
GROUNDING THE
GENERATOR
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure 3).
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth–driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING THE
GENERATOR
CAUTION! Never start or stop the engine with
electrical loads connected to the receptacles AND
with the connected devices turned ON.
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instruction steps by numerical order:
1. Turn the fuel valve to the On” position (Figure 4).
2. Place the choke lever in the Choke position
(Figure 5).
3. Set the rocker switch to On” position (Figure 6).
4. Grasp the recoil handle and pull slowly until slight
resistance is felt.Then pull rapidly to start engine.
5. Move choke lever to Run” position a short distance at
a time over several seconds in warm weather or
minutes in cold weather. Let engine run smoothly before
each change. Operate with choke in Run” position.
NOTE: If engine still fails to start after 3 pulls, check for
proper oil level in crankcase.This unit is equipped with a
low oil device which prevents the engine from being
started when the oil drops below a safe level in the
crankcase. See engine manual.
Refer to the engine owner’s manual for more
detailed starting instructions.
Fuel Valve is shown
in the On position
Figure 4 — Fuel Valve
Figure 5 — Choke Lever
Figure 6 — Rocker Switch
Figure 3 — Grounding Wing Nut
Grounding
Wing Nut
8
Briggs & Stratton Power Products Home Generator System
Owners Manual
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 and/or 240 Volt AC,
single phase, 60 Hz electrical loads.
Do Not connect 240 Volt loads to the 120 Volt duplex
receptacles.
Do Not connect 3–phase loads to the generator.
Do Not connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See
“Don’t Overload the Generator” on page 9.
Stopping the Engine
Unplug all electrical loads from generator panel
receptacles. Never start or stop engine with electrical
devices plugged in and turned ON.
Let engine run at no-load for several minutes to stabilize
the internal temperatures of engine and generator.
Move rocker switch to Off” position.
Move the fuel valve to the Off position.
RECEPTACLES
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 7).You can use the same 4–wire cord if you
plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 5,500 watts of power (5.5 kW)
at 30 Amps for 120 Volts or 240 Volts.The outlet is
protected by a push–to–reset circuit breaker.
CAUTION! Although this outlet states it has a
120/240 Volt 30 Amp rating (up to 7,200 watts), the
generator is only rated for 5,500 watts. Powering
loads that exceed the wattage/amperage capacity of
the generator can damage it or cause serious
injuries.
120 Volt AC, 20 Amp, Duplex
Receptacles
Each duplex receptacle (Figure 8) is protected against
overload by a push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
CAUTION!These outlets are rated at 120 Volt
20 Amp each (up to 80 Amps).The generator is only
rated for up to 45.8 Amps. Powering loads that
exceed the wattage/amperage capacity of the
generator can damage it or cause serious injuries.
Figure 8 — 120 Volt, 20 Amp Duplex Receptacle
Figure 7 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
240V
120V
120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-30
Ground (Green)
9
Briggs & Stratton Power Products Home Generator System
Owners Manual
DON'T OVERLOAD YOUR
GENERATOR
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 9.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500 -
Light (75 Watts) 75 -
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb - 75 watt
75
-
Deep Freezer
500
500
Sump Pump
800
1200
Refrigerator/Freezer - 18 Cu. Ft.
800
1600
Water Well Pump - 1/3 HP
1000
2000
Heating/Cooling
Window AC - 10,000 BTU
1200
1800
Window Fan
300
600
Furnace Fan Blower - 1/2 HP
800
1300
Kitchen
Microwave Oven - 1000 Watt
1000
-
Coffee Maker
1500
-
Electric Stove - Single Element
1500
-
Hot Plate
2500
-
Family Room
DVD/CD Player
100
-
VCR
100
-
Stereo Receiver
450
-
Color Television - 27”
500
-
Personal Computer w/17” monitor
800
-
Other
Security System
180
-
AM/FM Clock Radio
300
-
Garage Door Opener - 1/2 HP
480
520
Electric Water Heater - 40 Gallon
4000
-
DIY/Job Site
Quartz Halogen Work Light
1000
-
Airless Sprayer - 1/3 HP
600
1200
Reciprocating Saw
960
960
Electric Drill - 1/2 HP
1000
1000
Circular Saw - 7 1/4”
1500
1500
Miter Saw - 10”
1800
1800
Table Planer - 6”
1800
1800
Table Saw/Radial Arm Saw - 10”
2000
2000
Air Compressor - 1-1/2 HP
2500
2500
Figure 9 - Wattage Reference Chart
10
Briggs & Stratton Power Products Home Generator System
Owners Manual
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . . .8,500 watts
Continuous Wattage Capacity . . . . . . . . . . .5,500 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . .22.9 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 197 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine Maintenance
See engine owner’s manual for instructions.
If you need service for your engine, you need to determine
the engine identification number.To do so, remove the
rocker arm cover hood, item number 55 shown on
page 16, by removing the four nuts and washers holding it
in place.The engine model-type-trim number is stamped on
the side of the inner cover attached to the engine. Have
this number in hand when you call the engine service
center for assistance.
CAUTION! Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
To Clean the Generator
CAUTION! Never insert any object or tool
through the air cooling slots, even if the engine is
not running.
Use a damp cloth to wipe exterior surfaces clean.
A soft bristle brush may be used to loosen caked on dirt
or oil.
A vacuum cleaner may be used to pick up loose dirt and
debris.
Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
11
Briggs & Stratton Power Products Home Generator System
Owners Manual
STORAGE
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.
Generator Storage
Clean the generator as outlined in “To Clean the
Generator.
Check that cooling air slots and openings on generator
are open and unobstructed.
CAUTION! Storage covers can be flammable.
Do Not place a storage cover over a hot
generator. Let the unit cool for a sufficient time
before placing the cover on the unit.
Engine Storage
See engine owner’s manual for instructions.
Other Storage Tips
Do Not store gasoline from one season to another.
Replace fuel container if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
Store in clean and dry area.
12
Briggs & Stratton Power Products Home Generator System
Owners Manual
TROUBLESHOOTING
Problem
Cause
Solution
Engine is running, but
no AC output is
available.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good
condition.
4. Contact Briggs and Stratton service
facility.
Engine runs good but
bogs down when
loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See “Don’t Overload the Generator” on
page 9.
3. Contact Briggs service facility.
4. Contact Briggs service facility.
Engine will not start;
or starts and runs
rough.
1. Rocker switch set to “Off”.
2. Fuel valve is in the “Closed” position.
3. Dirty air cleaner.
4. Out of gasoline.
5. Stale gasoline.
6. Spark plug wire not connected to
spark plug.
7. Bad spark plug.
8. Water in gasoline.
9. Overchoking.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Set switch to “On”.
2. Turn fuel valve to the “Open” position.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Drain gas tank and fill with fresh fuel.
6. Connect wire to spark plug.
7. Replace spark plug.
8. Drain gas tank; fill with fresh fuel.
9. Set choke to “Off” position.
10. Contact Briggs service facility.
11. Contact Briggs service facility.
12. Contact Briggs service facility.
Engine shuts down
during operation.
Out of gasoline.
Fill fuel tank.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
1. See “Don’t Overload the Generator” on
page 9.
2. Replace air filter.
Engine “hunts” or
falters.
1. Choke is opened too soon.
2. Carburetor is running too rich or too
lean.
1. Move choke to halfway position till engine
runs smoothly.
2. Contact Briggs service facility.
13
Briggs & Stratton Power Products Home Generator System
Owners Manual
NOTES
14
Briggs & Stratton Power Products Home Generator System
Owners Manual
SCHEMATIC
15
Briggs & Stratton Power Products Home Generator System
Owners Manual
WIRING DIAGRAM
16
Briggs & Stratton Power Products Home Generator System
Owners Manual
EXPLODED VIEW – MAIN UNIT
17
Briggs & Stratton Power Products Home Generator System
Owners Manual
PARTS LIST – MAIN UNIT
Item Part # Qty Description
1 H189503GS 1 CRADLE
2 70642GS 2 MOUNT,Vibration, 45°
3 76222GS 4 PPHMS, M8 - 1.25 x 40 mm
4 66365GGS 1 HOUSING, Engine Adapter
5 187746GS 1 ASSEMBLY, Rotor (Inclds Item 7)
6 187745GS 1 ASSEMBLY, Stator
7 65791GS 1 BEARING
8 96796GS 1 WASHER, M8 Flat
9 190479GS 1 DECAL, Cover,Air Cleaner
10 86307GS 4 SCREW
11 99383GS 1 SCREW
12 67022GS 1 GROMMET, Rubber
13 189127GS 1 GROMMET, Rubber
14 189009GS 1 BRACKET, Muffler
15 188551GS 1 GASKET, Exhaust
16 66476GS 2 SCREW, w/Lock Washer
17 189008GS 1 MUFFLER
18 60706GS 2 SCREW
19 83083GS 1 SCREEN, Spark Arrest
20 81917GS 1 PIN, 4mm x 10 Roll
21 67989GS 10 NUT, Flange Serrated
22 28739AGS 1 TIE WRAP
23 86292GS 1 SCREW, Self Drilling
24 J190061GS 1 SHIELD, Heat
25 SRV66825DGS 1 CARRIER, Rear Bearing
26 74908GS 5 TAPTITE, M5-0.8 x 10
27 86308AGS 4 BOLT, Stator
28 84409GS 1 SLEEVING, Flexo
29 22695GS 1 FASTEN, On Tab Housing 6P
30 84242GS 1 GROMMET, Plastic
31 77816GS 1 DECAL, Hot Muffler
32 91825GS 1 ASSEMBLY, Brush Holder
33 66849GS 2 TAPTITE
34 B4871GS 1 COVER, Bearing Carrier
35 23762GS 2 WASHER, Shakeproof
36 86494GS 1 SCREW,Wing
Item Part # Qty Description
37 B2153GS 2 SCREW, Self Drilling
38 56893GS 5 SCREW, Crimptite
39 190479GS 2 DECAL, Heat Shield
40 77395GS 4 NUT, M6 Flange Lock
41 80270GS 1 VALVE,Tank
42 78299GS 1 BUSHING, Plastic Tank
43 83465GS 4 GROMMET,Tank
44 78831BGS 4 HHCS, M6 - 1.0 x 60, SEMS
45 B4363GS 1 CAP, Fuel Gauge
46 22097GS 4 WASHER, Lock
47 22127GS 4 NUT
48 14353621GS 1 WIRE, Ground
49 26850GS 2 WASHER, M6 Shakeproof
50 B4986GS 1 DECAL, Ground, Green
51 92982GS 1 DECAL, Danger
52 189235GS 1 DECAL, Start Instructions
53 85652GS 2 MOUNT,Vibration
54 92665GS 1 INSULATION
55 187330GS 1 HOOD, Rocker Arm Cover
56 85000GS 1 CLIP, Insulation
57 B1998GS 1 ASSY.,Tank, Fuel 7-Gallon
(Includes Items 41 & 42)
58 189157GS 1 ASSEMBLY, Control Panel
59 189164GS 4 NUT, Palnut
60 J92039GS 1 SHIELD, Heat
61 190477GS 1 MANUAL, Owners
62 BB3061GS 1 BOTTLE, Oil, 28 oz
63 190780GS 1 DECAL, 1-800
64 189521AGS 1 WIRE, Ground, Panel
65 188826GS 1 MANUAL, Engine
66 190479GS 1 DECAL, Panel, Control
67 73054GS 1 DECAL, Fuel Shut-off
68 H190018GS 1 PLATE, Stiffener
69 48031CGS 2 CLAMP, Hose
70 30340GS 1 HOSE, Fuel
900 NSP 1 ENGINE
18
Briggs & Stratton Power Products Home Generator System
Owners Manual
EXPLODED VIEW AND PARTS LIST – WHEEL KIT
Item Part # Qty Description
1 189715GS 1 ASSEMBLY, Handle
2 B187101GS 1 LEG, Mounting
3 52858GS 5 NUT, Locking Hex M8 - 1.25
4 39287GS 2 HHCS, M8 - 1.25 x 45
5 93693GGS 1 AXLE
6 B4966GS 2 WHEEL, 10" Diameter
7 87005AGS 2 PIN, Retaining
8 22247GS 2 WASHER, Flat, 5/8"
9 39253GS 1 HHCS, M8 - 1.25 x 20
10 42909GS 2 HHCS, M8 - 1.25 x 30
11 22145GS 2 WASHER, Flat, 5/16 - M8
12 27007GS 2 MOUNT,Vibration
19
Briggs & Stratton Power Products Home Generator System
Owners Manual
EXPLODED VIEW AND PARTS LIST – CONTROL PANEL
Item Part # Qty Description
1 188914GS 1 COVER, Lid, Control Panel
2 188889GS 1 CONTROL PANEL, Compact
3 189167GS 2 CLIP, Hinge Pin Retainer
4 189182GS 2 SPRING, Hinge, Pin
5 189166GS 2 PIN, Hinge, Cover, Compact
6 68759GS 2 OUTLET, 120V, 20Amp, Duplex
7 189165GS 4 NUT, Palnut, Pushnut, 5/32
8 84198GS 2 CAP, Circuit Breaker
9 75207GS 2 CIRCUIT BREAKER
10 43437GS 1 OUTLET, 120/240 Locking, 30A
11 189164GS 2 NUT, Palnut, Pushnut, 3/16
12 84543CGS 2 SCREW, Phillips, Head 3.5 x 18
13 93857GS 1 BAR, Retaining
14 188890GS 1 COVER, Back, Control Panel
15 82308GS 6 SCREW, Self Tapping, STC 3x
16 22694GS 1 HOUSING, Receptacle
Sistema de Generador Doméstico de Briggs & Stratton Power Products
Manual del Propietario
20
TABLA DE CONTENIDOS
Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
Ensamblaje. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Conozca Su Generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Funcionamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-27
Especificaciones Del Producto / Mantenimiento . . . . . . . . . . . . 28
Almacenamiento. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Diagnosticos De Averías . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Esquemático / Digrama Eléctrico . . . . . . . . . . . . . . . . . . . . . 14-15
Piezas De Recambio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-19
DESCRIPCIÓN DEL EQUIPO
Lea este manual de manera cuidadosa y familiarícese con
su generador. Conozca sus usos, sus limitaciones y
cualquier peligro relacionado con el mismo.
Este generador funciona en base a un motor, de campo eléctrico
giratorio y de corriente alterna (AC). Fue diseñado con la
finalidad de proveer energía eléctrica para luces eléctricas,
aparatos, herramientas compatibles y cargas de motor. El campo
giratorio del generador funciona a una velocidad de 3,6000 rpm
usando un motor con un solo cilindro.
¡PRECAUCIÓN! No sobrepase la capacidad de vataje y
amperaje del generador. Revise "No Sobrecargue el Generador"
en la página 27.
Se ha hecho cada esfuerzo posible para asegurarse que la
información que aparece en este manual es exacta y se encuentra
actualizada. Sin embargo, Briggs and Stratton se reserva el
derecho a cambiar, alterar o de otra manera mejorar, el producto
y este documento en cualquier momento, sin previo aviso.
El Sistema de Control de Emisiones para este generador está
garantizado para juegos estándares por la Agencia de Protección
Ambiental. Para mayor información acerca de la garantía, consulte
con el manual del propietario del motor.
INSTRUCCIONES DE SEGURIDAD
El símbolo de alerta de seguridad ( ) es usado con una palabra
(PELIGRO,ADVERTENCIA, PRECAUCIÓN), un mensaje por
escrito o una ilustración, para alertarlo acerca de cualquier
situación de peligro que pueda existir. PELIGRO indica un riesgo
el cual, si no se evita, causará la muerte o una herida grave.
ADVERTENCIA indica un riesgo el cual, si no se evita, puede
causar la muerte o una herida grave. PRECAUCIÓN indica un
riesgo, el cual, si no se evita, puede causar heridas menores o
moderadas. PRECAUCIÓN, cuando se usa sin el símbolo de
alerta, indica una situación que podría resultar en el daño del
equipo. Siga los mensajes de seguridad para evitar o reducir los
riesgos de heridas e inclusive la muerte.
El escape del motor de este producto contiene
elementos químicos reconocidos en el Estado de
California por producir cáncer, defectos de nacimiento u
otros daños de tipo reproductivo.
ADVERTENCIA
Opere el generador SOLAMENTE al aire libre.
Mantenga al menos 2 pies de espacio libre alrededor del
generador, para la adecuada ventilación.
No opere el generador dentro de un edificio o lugar cerrado,
incluyendo el compartimiento del generador en un vehículo
recreativo o RV.
Al generador funcionar, se produce monóxido de
carbono, un gas inodoro y venenoso.
El respirar el monóxido de carbono, producirá
náusea, desmayo o la muerte.
PELIGRO
CUANDO AÑADA COMBUSTIBLE
Apague el generador (posición OFF) y déjelo enfriar al menos por
2 minutos antes de remover la tapa de la gasolina.Afloje la tapa
lentamente para dejar que la presión salga del tanque.
Llene el tanque al aire libre.
No llene demasiado el tanque. Permita al menos espacio para la
expansión del combustible.
Mantenga la gasolina alejada de chispas, llamas abiertas, pilotos, calor y
otras fuentes de ignición.
No encienda un cigarrillo o fume.
CUANDO OPERE EL EQUIPO
No incline el motor o el equipo, de tal manera que la gasolina se
pueda derramar.
CUANDO TRANSPORTE O REPARE EL EQUIPO
Transporte o repare el equipo con el tanque de combustible vacío, o
con la válvula para apagar el combustible, apagada (posición OFF).
Desconecte el cable de la bujía.
CUANDO ALMACENE O GUARDE EL EQUIPO CON
COMBUSTIBLE EN EL TANQUE
Almacene alejado de calderas, estufas, calentadores de agua, secadoras
de ropa u otros aparatos electrodomésticos que posean pilotos u
otras fuentes de ignición, porque ellos pueden encender los vapores
de la gasolina.
La gasolina y sus vapores son extremadamente
inflamables y explosivos.
El fuego o una explosión pueden causar quemaduras
severas e inclusive la muerte.
ADVERTENCIA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Briggs & Stratton 01677-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à