IMPORTANT WARNING
WARNING
DANGER
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
For outdoor use only
Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
FIRE OR EXPLOSION HAZARD
If you smell gas:
Shut off gas to the appliance.
Extinguish any open flame.
If odor continues, leave the area immediately.
After leaving the area, call your gas supplier or fire department.
Failure to follow these instructions could result in fire or explosion,
which could cause property damage, personal injury, or death.
If the information in this manual is not followed exactly,
a fire or explosion may result causing property damage
personal injury or loss of life.
Read the installation, operation
and maintenance instructions
thoroughly before installing or
servicing this equipment.
Save these instructions for
future reference. If you are
assembling this unit for someone
else, give this manual to him or her
to read and savefor future
reference.
Do not store or use gasoline or other
flammable vapors and liquids, in the
vicinity of this or any other appliance.
This unit is not for use with propane.
Use only with Natural gas.
!
!
!
!
!
US
R
C
WARNING
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
Improper Installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage.
Manual No.: ANGE11EN-G101-A4
ELEMENTI
THE ART OF FIRE
Lunar Bowl Fire Table
OFG101NG
Owner's Manual
Gas type: Natural Gas
Important Safety Information -----------------------------------------------------------------------3
Natural Gas Warnings -------------------------------------------------------------------------------5
Parts List ------------------------------------------------------------------------------------------------7
Pre-use Instructions ---------------------------------------------------------------------------------12
Lighting Instructions ---------------------------------------------------------------------------------13
Care and Cleaning -----------------------------------------------------------------------------------14
Gas Component Connection Checks -----------------------------------------------------------15
Troubleshooting --------------------------------------------------------------------------------------17
Warranty -----------------------------------------------------------------------------------------------19
TABLE OF CONTENTS
2 / 20
WARNING: This product can expose you to Carbon
monoxide, which is known to the Sate of California to
cause birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov .
WARNING: This product can expose you to Lead/
Di(2-ethylhexyl)phthalate(DEHP) , which is known to the
Sate of California to cause cancer and birth defects or
other reproductive harm. For more information go to
www.P65Warnings.ca.gov .
WARNING: This product can expose you to
Disononyl phthalate (DINP), which is known to the Sate
of California to cause cancer. For more information go to
www.P65Warnings.ca.gov .
WARNING: This product can expose you to
Butylbenzyl phthalate (BBP)/Di-n-butyl phthalate (DBP) ,
which is known to the Sate of California to cause birth
defects or other reproductive harm. For more information
go to www.P65Warnings.ca.gov .
!
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
3 / 20
IMPORTANT SAFETY INFORMATION
!
WARNING FIRE TABLE IS FOR OUTDOOR USE ONLY
IF YOU SMELL GAS
• Shut off gas supply to the fire table.
• Extinguish any open fame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a qualified service person. More frequent cleaning may
be required as necessary. It is imperative that the control compartment, burners, and circulating air
passageways of the appliance are kept clean.
WARNING: Always shut off gas supply at the shut-off valve and disconnect the quick disconnect
socket from the main gas supply when the fire table is not in using.
WARNING: Installation and service must be performed by a qualified installer, service agency or gas
supplier.
WARNING: Failure to follow with the safety warnings and precautions in this manual may result in
serious bodily injury or death, a fire or an explosion causing damage to property.
IMPORTANT NOTICE: Read and understand all warnings and precautions prior to assembly and
use your gas fire table. Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage.
• NOTE: The use and installation of this product must conform to local codes, or in the absence of
local codes with the National Fuel Gas Code, ANSI Z223.1 • NEPA 54; Natural Fuel Gas code ;
Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling code
B149.2; This appliance complies with ANSI Z21.97-2017• CSA2.41-2017 Outdoor Decorative Gas
Appliances Standards.
•Minimum Clearance from Unit to Combustible Materials
72”(182.9cm) minus the height of appliance from the top; 48” (121.9cm) from all sides and back.
Do not locate this fire table under any overhead enclosure.
The minimum inlet Natural Gas supply pressure: 3.5'' w.c. (0.87kPa).
The maximum inlet Natural Gas supply pressure: 10.5'' w.c. (2.61kPa).
The manifold pressure of this appliance is 7'' w.c. (1.74kPa).
Always use this outdoor fire table on a hard, level non-combustible surface such a concrete, rock or
stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces such as dirt
and grass may prevent the unit from having proper ventilation.
• This gas fire table and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 of psi (3.5 kPa).
• The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
• Keep these instructions for future reference. If you are assembling this unit for someone else,
give this manual to him or her to read and keep for f utu re reference.
• This gas fire table must be used ONLY outdoors in a well-ventilated space and shall NOT be
used inside a building, garage, or any other enclosed area.
4 / 20
IMPORTANT SAFETY INFORMATION
• DO NOT use this outdoor gas fire table for indoor heating. Toxic carbon monoxide fumes can
accumulate and cause asphyxiation.
• NEVER leave this gas fire pit unattended when in use.
Children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
• DO NOT store or use gasoline or other flammable vapors and liquids within 25 feet (7.62m) ofthis or
any other appliance.
• DO NOT store any combustible materials in the baseenclosure.
• DO NOT use in an explosive atmosphere. Keep gas fire table area clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
This outdoor fire table is NOT to be operated by children. Young children should beclosely supervised
when in the vicinity of this outdoor firetable.
• This outdoor fire table is not to be installed or used in or on recreation vehicles and/orboats.
Always use in accordance with all applicable local, state and national codes. Contact your local fire
department for details on outdoor burning.
• Use the same precautions you would with any open fire when using this outdoor firetable.
• DO NOT burn solid fuels such as: wood, charcoal briquettes, lump charcoal, manufactured logs,
driftwood, trash, leaves, paper, cardboard, plywood, painted orstained or pressure treated wood in this
outdoor fire table.
• DO NOT use this outdoor fire table until it is completely assembled and all parts aresecurely fastened
and tightened.
• DO NOT use this outdoor fire table near automobiles, trucks, vans or recreationalvehicles.
• DO NOT use this outdoor fire table under any overhead structure or near anyunprotected combustible
constructions. Avoid using near or under overhanging trees and shrubs.
• The use of alcohol, prescription or non-prescription drugs may impair an individual’s abilityto properly
assemble or safely operate this outdoor firetable.
• DO NOT use this outdoor fire table if any part has been under water. Immediately call a qualified
service technician to inspect the fire table and to replace any part or control system and any gas control
which has been under water.
• DO NOT wear flammable or loose clothing when operating this outdoor fire table.
• DO NOT use in windy conditions.
• Keep all electrical cords away from a hot outdoor fire table.
• Certain areas of this outdoor fire table when in use will become too hot to touch. Do not touch hot
surfaces until the unit has cooled unless you are wearing protective gear such as insulated pot holders
or heat resistant gloves or mittens to avoid burns.
DO NOT hang or place clothing or other flammable materials on or near the gas fire table.
Any guard or other protective device removed for servicing the fire table must be replaced prior to
operating the fire table.
• DO NOT attempt to move or store this outdoor fire table until all part s are cool.
• DO NOT lean over this outdoor fire table when lighting or when in use.
• Use only the natural gas hose and quick disconnect assembly provided. The replacement
natural gas hose and quick disconnect assembly shall be that specified by the manufacturer.
• DO NOT attempt to disconnect natural gas hose or quick disconnect socket from the main gas supply
or any gas fitting while the outdoor fire table is in use.
Always shut off the gas s upply at the shut-off valve and disconnect the quick disconnect socket
from the main gas supply when the fire table is not in use.
• DO NOT sit on the fire table when the unit is in operation.
• DO NOT throw anything onto the fire when the unit is in operation.
• Lava rocks are very hot; please keep children and pets at a safe distance.
5 / 20
IMPORTANT SAFETY INFORMATION
• It is essential to keep the outdoor fire table valve compartment, burners, and circulating air passages
clean. Inspect outdoor fire table before each use.
• Prior to each fire table operation, check the hose for evidence of excessive abrasion or wear by looking
through the visual check hole. If the hose is damaged,cracked or cut, it must be replaced before using
the gas fire table. The hose assembly can only be replaced with a hose assembly specified by the
manufacturer. Please contact Elementi at 800-678-7294 for technical support. Use only replacement
parts from the manufacturer.
• Before each use, remove the lava rocks. Examine the burner and its components. If dirty, clean
with a soft brush and soapy water solution. Examine the area around the burner; any dirt or
foreign material, such as spider webs or nests in this area should be removed. If it is evident that
the burner is damaged, the fire table must not be used. The burner assembly cannot be replaced.
Please contact Elementi at 800-678-7294 for technical support.
• Place the hose out of the pathways where people may trip over it. Do not place the hose
in areas where it may be subjected to accidental damage.
WARNING
!
ATTENTION: Any alteration of the outdoor fire table that is not specifically directed in the operations
manual will void manufacturer warranty.
Natural gas is flammableand hazardous if handledimproperly. Become aware of the characteristics
before using any natural gas product.
Natural Gas Characteristics:
• Flammable, explosiveunder pressure, lighter than air and settles in pools in high areas.
• In its natural state, natural gas has no odor. For your safety,an odorant has been added.
• Contact with natural gas could burn the skin.
• Natural gasisextremelyflammableandhazardousifhandledimproperly.
• Chemicals known to the state of California to cause cancer, birth defects, or other reproductiveharm
arecreated by thecombustion ofnatural gas.
• Your natural gas fire pit is designed to operate on natural gas only, at a pressure of seven inches’
water column (7" W.C.) Check with your gas utility forlocal gas pressure, because in some areas
natural gas pressure varies. Also, check with your gas company or with local building codes for
instructions to install gas supply line, or call a licensed and qualified installer.
• It is recommended that an ON/OFF manual shut-off valve be installed at the gas supply source:
Outdoors: After the gas line exits outside wall and before quick-disconnect or before gas supply
line enters ground.
Indoors: In the branch gas line in an accessible location near the gas supply line.
• Pipe sealing compound or pipe thread tape of the type resistant to the action of natural gas must be
used on all male pipe threads. Apply compound or tape to at least the first three to four threads when
making aconnection.
This outdoor fire table is for use with Natural Gas only. The conversion to or attempted use of
Liquid Propane in this outdoor fire table is dangerous and could result in serious personal injury,
or property damage.
NATURAL GAS DANGERS AND WARNINGS
6 / 20
NATURAL GAS DANGERS AND WARNINGS
• Never store or use gasoline or other volatile substance in the vicinity of this fire table.
Natural Gas Connection
Connect a manual shut-off valve to gas supply line. Apply sealing compound or pipe thread tape of
the type resistant to the action of natural gas on all male pipe threads. Connect the end, with the
quick release connector, or the natural gas hose to manual shut-off valve at the gas supply.
WARNING
!
During any high pressure testing of the gas supply piping system at test pressures in excess of
½ psi (3.5 kPa), the appliance and its individual shut-off valve must be disconnected from the gas
supply piping system.
The outdoor fire table must be isolated from the gas supply piping system by closing the individual
manual shut-off valve during any pressure testing of the gas supply piping system at least equal to
or less than 1/2 psi (3.5 kPa).
WARNING
!
Burner valves are pre-tested at the factory to operate on natural gas. Do not attempt to convert
or change.
7 / 20
PARTS LIST
Item Picture Description Qty.
01 Burner 1 pc
03 Fixed block 4 pcs
02 Guard 1 pc
04 Air inlet pipe A 1 pc
05 Air inlet pipe C 1 pc
08 Corrugated Pipe 2 pcs
09 Gas valve 1 pc
10 Natural Gas Hose 1 pc
12 Thermocouple 1 pc
11 Electrode 1 pc
13 Ground wire 1 pc
14 Ignitor 1 pc
15 Control Knob 1 pc
16 Control Panel 1 pc
17 Fire bowl 1 pc
19 Lava Rock 12 kgs
20 Cover 1 pc
02
10
09
07
08
WARNING
For technical support or replacement parts or missing parts please contact
Elementi at 800-678-7294.
!
14
15
16
11
12
13
18
03
04
05
06
06 Orifice 1 pc
07 Air inlet pipe B 1 pc
21 Fire Pit 1 pc
18 Battery 1 pc
19
21
20
17
01
8 / 20
ASSEMBLY INSTRUCTIONS
1
Install the AAA battery as shown in the diagram below. Battery not included.
2
Place lava rock by hand. DO NOT dump bag out in to the tray to avoid clogging the
burner with dust. Position the lava rock to a level about 1” above the t op of the
burner. Make sure that you do not block the igniter box with lava rock to ensure
proper ignition.
9 / 20
ASSEMBLY INSTRUCTIONS
3
Connecting your Fire Table to the Natural Gas Source
A professionally installed shut-off valve between the supply piping and the socket
is recommended by the National Fuel Gas Code. Socket connection must be made
outdoors.
FIREPIT
FIREPIT
Adjustable feet has pre-installed on the bottom of fire pit already. Please adjust the hight of
feet to make sure all fire pit was on level always, or increase the height of fire table as your
preference. Please make sure the height was safty before you complete.
10 / 20
ASSEMBLY INSTRUCTIONS
4
Connecting the Socket
Coat the gas supply pipe nipple with gas resistant pipe compound or approved
Teflon PTFE tape. Screw socket onto gas supply pipe (house gas source) as shown
to the right, and wrench tighten. The quick disconnect socket should never be
connected to the fire table. Direction of gas flow is indicated on the socket.
ASSEMBLY INSTRUCTIONS
5
Using the Quick Connect Socket
Pull back the sleeve on the quick disconnect socket and insert the unattached end
of the gas hose into the socket. Release the sleeve and continue pushing the hose
into the socket until the sleeve snaps into the locked position. After making all
connections, perform a leak test as described on page 12 of this manual.
11 / 20
12 / 20
PRE-USE INSTRUCTIONS
WARNING
!
Failure to inspect this connection or follow these instructions could cause a fire or an explosion.
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Elementi at 800-678-7294 for assistance.
Checking for Leaks
Make a leak check solution by mixing 1-part dishwashing soap
with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, turn natural gas on at
its source.
Spray leak solution on valve connections paying particular
attention to the areas indicated by arrows.
If any bubbles appear turn natural gas off, reconnectand
re-test. If you continue to see bubbles after several attempts,
disconnect natural gas source and contact Elementi at
800-678-7294 for assistance.
If no bubbles appear after one-minute turn source OFF, wipe
away solution and proceed.
Check for leaks at these locations
WARNING
!
Before using this outdoor fire table, make sure you have read,
understand and are following all information provided in the Important Safety Information section
of this manual. Failure to follow those instructions can cause death, serious injury or property
damage.
Prior to each gas fireplace operation, check the hose and valve for evidence of excessive abrasion or
wear though the visual check hole on the side of the base. Replace visual check cap prior to operating
fireplace.
BURNER CONNECTIONS
Make sure the Natural Gas hose and quick disconnect socket connections are securely fastened to
the burner and the gas supply. If your unit was assembled for you, visually check the connection
between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.
13 / 20
LIGHTING INSTRUCTIONS
Using the Ignitor
1. Read instructions before lighting.
2. Burner control knob must be in the “OFF” position.
3. Connect natural gas source (see above pages).
4. Open the natural gas supply to the unit.
5. Push and hold igniter but t urn to create sparks.
6. While holding the igniter button with one hand, use your other hand to push and turn the control knob
to the “LOW” position to light the burner.
7. If ignition does not occur in 5 seconds, push and turn the Control Knob to “OFF”, wait 5 mimutes and
allow gas to dissipate.
8. Once the burner is lit, continue to hold the knob in for another 20 seconds and release.
9. Observe flame, make sure all burner ports are lit. Flame height should be no higher than 13 inches tall.
10. Adjust flame to desired flame with the control knob.
Using a Long Match or Lighter
1. Prior to lighting, use a shovel to move lava rocks for access to
the burner.
2. Wearing heat resistant gloves, position the burning long match
or burning butane lighter near the side of the burner. DO NOT lean
over the fire table while lighting!
3. Turn control knob counterclockwise to “LOW”.
4. Remove long match/long butane lighter.
5.After lighting, use a shovel and heat resistant gloves to carefully
move the lava rocks back into their proper position.
6. Observe flame, make sure all burner ports are lit. Flame height
should be no higher than 13 inches tall.
7. Adjust the flame to the desired height with the control knob.
Keep the lava rock covered and make sure it is dry before igniting.
!
WARNING
!
When using this method to
light your fire table use heat
resistant gloves and follow
the step by step instructions.
Failure to do so could result
in severe injury.
WARNING
!
If burner fame goes out during operation, immediately urn
the control knob “OFF” and let the gas clear a minimum of
5 minutes before attempting to re-light the fire table.
Please refer to the trouble shooting pages for additional support,
beginning on page 17.
TURNING OFF
1.Push and turn the control knob clockwise to the “OFF”position.
2.Shut off gas supply at the shut-off valve and disconnect the quick disconnect socket from the main
gas supply.
14 / 20
CARE AND CLEANING
Inspecting
This outdoor fire table must be inspected regularly to insure that the product is safe to use and to
extend product life.
WARNING
!
1. Check the burner to make sure it is securely in place.
2. Check all gas connections for leaks.
3. Check ignition system to insure proper sparking.
4. Check components for any signs of damage, rust or excessive wear.
5. If damage to any component is detected, DO NOT operate until the proper repairs have been made.
WARNING
!
DO NOT tamper with this appliance. This is DANGEROUS and will void the
warranty. Any part found to be faulty must be replaced with an approved part,
confirmed by manufacturer. For technical support contact Elementi at
800-678-7294
WARNING
!
DO NOT inspect this outdoor fireplace until the fire is
COMPLETELY out.
DO NOT move or store this fire table unless the fire is COMPLETELY out and
cool to the touch.
General Care and Cleaning
This outdoor fireplace should be cleaned regularly to ensure safe use and extend product life.
Note: After repeated use, a slight discoloration of the finishes may occur.
Table
1. Wipe exterior surfaces with a mild dish washing soap or baking soda, then rinse clean with water.
Stainless Steel
1. For general cleaning use warm water, soap, ammonia, or detergent apply with a soft cloth or Sponge
2. For finger prints or smears use 3M Stainless Steel Cleaner and Polish, Arcal 20, Lac-O-Nu, LuminWash,
O’Cedar Cream Polish, or Stainless Shine, this will provide a barrier file to minimize fingerprints.
3. For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish, Allchem Concentrated
Cleaner, Samae, Twinkle, Cameo Copper Cleaner, Liquid Nu Steel, Coppers or Revere Stainless Steel
Cleaner, apply using a soft cloth in the same direction of the polish lines.
4. While using in salt air environments we recommend cleaning all stainless steel surfaces at least every two
weeks to keep the item in prime condition. Stainless steel is corrosion-resistant but it is not impervious to rust.
Exposure to salt air and sea spray will cause surface rust if you do not care for your products properly.
The best thing you can do to protect the stainless steel is to clean it frequently.
* Use of proprietary names is intended only to indicate a type of cleaner and does not constitute endorsement. Omission
of any proprietary cleanser does not imply its inadequacy. All products should be used in strict accordance with
instructions on package.
Storage
1. Turn off the gas supply and disconnect the quick connect valve.
2. Carefully remove rock filler and store components flat to protect them from breakage.
3. ALWAYS cover your outdoor fire table when not in use.
4. Store in a cool, dry location away from children and pets.
15 / 20
GAS COMPONENT CONNECTION CHECKS
If the burner will not light or stay lit, please perform the following checks.
1. Make sure the electrode wire is correctly connected. Both electrode wires must be fully inserted
into the igniter box.
2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the igniter
pin, thermocouple and the burner tube.
CORRECT
INCORRECT
Igniter Box
Thermocouple
Wire
Igniter Box
Valve
the inner
side
GAS COMPONENT CONNECTION CHECKS
Thermocouple
Igniter Pin
16 / 20
Thermocouple Wire
Valve
Wire should
be in line
with valve
Valve
Igniter Box
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
Thermocouple
Wire
5mm /
0.196”
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm / 0.196” away from the burner tube.
TROUBLESHOOTING
17 / 20
Problem: Burner will not light using igniter
Possible Cause 1: Electrode and burners are wet.
-Wipe dry with cloth.
Possible Cause 2: Igniter battery is dead or backwards.
-Check that the AAA battery is inserted correctly in the igniter (see page 8) or replace the battery.
Possible Cause 3: Igniter Pin cracked or broken - sparks at crack.
-Call ELEMENTI at 800-678-7294 for technical support.
Possible Cause 4: Wire loose or disconnected.
-Reference page 15, step 1, reconnect wire. Call ELEMENTI at 800-678-7294.
Possible Cause 5: Wire is shorting (sparking) between igniter and electrode.
-Call ELEMENTI at 800-678-7294 for support.
Possible Cause 6: Bad Igniter.
-Call ELEMENTI at 800-678-7294 for supporting.
burner
Burner Ports
thermocon
Igniter Pin
Problem: Burner will not light with match
Possible Cause 1: No Gas Flow.
-Check if Natural Gas supply is stopped. If it is not stopped, refer to “Problem: Sudden drop in gas
flow” on the following page.
Possible Cause 2: Quick Connect not fully engaged.
-Disconnect the quick connect at the gas supply and reconnect to ensure a proper connection is made.
Possible Cause 3: Obstruction of gas flow.
- Check for bent or kinked hose.
Possible Cause 4: Burner ports clogged or blocked.
-Reference “Problem: Irregular flame pattern” on the following page.
Clean the burner ports as described there.
Problem: The Fire Table emits a lot of black smoke when in use
Possible Cause 1: Hose from gas fireplace is pinched.
-Make sure the hose is not pinched between the fire table and
the source of the gas.
Possible Cause 2: Flame is being obstructed at burner ports.
-Make sure that the gas ports on the burner are free of any lava
rocks so that the flame can flow naturally.
Burner Ports
5mm /
0.196”
5mm /
0.196”
TROUBLESHOOTING
18 / 20
Problem: Irregular flame pattern,flame does not run the full length of the burner
Possible Cause: Burner ports are clogged or blocked.
-Clean burner ports. Do this by inserting a paperclip into each of the burner ports to ensure they are
not clogged.
WARNING: Make sure burner is not on and the gas supply has been properly disconnected. Allow
15 minutes for unit to cool before touching it.
Problem: Flame blow out
Possible Cause 1: High or gusting winds.
-Increase flame to “HIGH” setting.
Possible Cause 2: Low on Natural gas.
-Call your local gas company.
Possible Cause 3: Excess fl ow valve tripped.
-Refer to “Problem: Sudden drop in gas flow”.
5mm /
0.196”
Burner Ports
Problem: Sudden drop in gas flow, or a reduced flame height
Possible Cause 1: Out of gas.
-Call your local gas company.
Possible Cause 2: Excess flow safety device may have been activated.
-Turn control knob to “OFF”, wait 30 seconds and light outdoor fire table. If flames are still too low reset
the excessive flow safety device by turning off the control knob and the gas supply.
Disconnect the quick disconnect socket.
Turn Burner Control Knob to "HIGH". Wait 1 minute.
Turn Burner Control Knob off.
Reconnect the quick disconnect, turn on the main gas supply and perform a leak check at the Natural
Gas connection.
19 / 20
Warranty
Ocean Rock USA INC. doing business as Elementi, warrants Elementi fire features and
accessories to be free from defects in parts and workmanship under normal use and service for
a period of 1 year from the date of purchase. In the event of such defects Elementi will, at its
option, repair or replace the defective product. The foregoing is at the discretion of Elementi.
There will be no charge for the replacement parts or product, however it will be the consumer’s
responsibility to return the product to the original place of purchase.
Elementi will not be responsible for consequential damages in excess of the purchase price of
the product on which such liability is based and the warranty does not cover costs including
freight, removal and reinstallation.
This warranty is non-transferable and applies only for units that are for non-commercial personal
use only.
Under this warranty agreement, all gas lines must be installed by a licensed gas fitter.
Damage caused by shipping, staining and abuse are not covered under this warranty. Dings,
dents and scratches, fading and natural weathering are not covered under this warranty.
Decorative rock is not covered under this warranty. Improper installations, repair or
modifications made by anyone other than Elementi will void this warranty and any damage
caused by such is also not covered under this warranty.
Minor chipping, weather fading, water staining and non-structural hairline cracks are typical of
the material of this product and are not covered under this warranty. Some color and texture
variation is typical of the material and finish for this product and is not covered under this
warranty.
Cast concrete is a hand finished process. As such, this product’s finish will vary by unit. There
will be a color variance of up to 15% in each unit. There may also be uneven texture or pattern
as well as small holes in the surface caused by air or water trapped on the surface during
casting. This is a normal trait of cast concrete and is not covered under warranty.
Ocean Rock USA INC.
692 Parkridge Ave Norco, CA 92860, USA
www.elementifire.com
Tel: 800-678-7294
ELEMENTI
THE ART OF FIRE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Elementi OFG104-NG Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues