Pepperl+Fuchs LUC-M40 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

de
en
fr
es
it
nl
fi
sv
da
pt
el
Sicherheitshinweise für elektrische Betriebsmittel
zum Einsatz in explosionsgefährdeten Bereichen.
Safety instructions for electrical apparatus certified
for use in explosion-hazardous areas.
Conseils de sécurité pour matériels électriques
destinés aux zones explosibles.
Instrucciones de seguridad de aparatos eléctricos homologados
para su utilización en áreas expuestas a riesgos de deflagración.
Si no entiende este manual, puede pedir un ejemplar en su idioma.
Istruzioni di sicurezza per apparecchiature elettriche certificate
per l'utilizzo in aree con pericolo di esplosione.
Se il presente manuale non risulta comprensibile potete ordinarcene
una copia tradotta nella vostra lingua.
Veiligheidsinstructies voor elektrisch materieel
in explosiegevaarlijke omgeving.
Wanneer u deze handleiding niet kunt lezen, kunt u een in uw
landstaal vertaalde handleiding bij ons bestellen.
Turvallisuusohjeita sähkölaitteille, jotka on vahvistettu
käytettäväksi räjähdysvaarallisilla alueilla.
Jos et ymmärrä tätä käsikirjaa, voit tilata meiltä käännöksen omalla
kansallisella kielelläsi.
Säkerhetsföreskrifter för elektrisk utrustning certifierad
för användning i explosionsfarliga områden.
Om du inte förstår denna manual, kan en översatt kopia på ditt eget
språk beställas från oss.
Sikkerhedsforskrifter for elektriske apparater certificeret
til brug i eksplosionsfarlige områder.
Hvis du ikke forstår denne manual, kan en oversat kopi af den på dit
eget sprog bestilles fra os.
Instruções de segurança para dispositivos eléctricos certificados
para utilização em áreas de risco de incêndio.
Se não compreender este manual, pode encomendar-nos
directamente uma cópia na sua língua.
Oäçãßåò áóöáëåßáò ãéá çëåêôñéêÝò óõóêåõÝò ðoõ åãêñßíoíôáéãéá
÷ñÞóç óå ðåñéo÷Ýò ìå êßíäõío åêñÞîåùí.
Áí äåí ìðoñåßôå íá êáôáíoÞóåôå ôo ðåñéå÷üìåío ôoõ åã÷åéñéäßoõ
áõôoý, ìðoñåßôå íá ðáñáããåßëåôå áðü ôçí åôáéñåßá ìáò Ýíá
áíôßôõðoìåôáöñáóìÝío óôç ãëþóóá óáò.
SI 175O-C
52027559
Code: a3/08.05
KEMA 05 ATEX 1111
Ultraschall-Füllstandssensor
LUC-M10, LUC-M20, LUC-M40
F12-Gehäuse, PROFIBUS PA oder
FOUNDATION Fieldbus
fr
es
it
nl
fi
sv
52027559
Déclaration de conformité
Par la présente déclaration et par
l’application de la marque CE, le
fabricant Pepperl+Fuchs, Allemagne,
garantit que le produit est conforme
aux prescriptions de la directive CEM
européenne 89/336/CE et de la
directive 94/9/CE. Cette conformité
est attestée par le respect des
normes.
Declaración de conformidad
Por la presente declaración y la
inclusión de la marca CE, el
fabricante Pepperl+Fuchs, Alemania,
garantiza que el producto cumple lo
estipulado por la Directiva
CEM 89/336/CEE y la Directiva
94/9/CE. La prueba de conformidad
se presenta según las normas
expuestas.
Dichiarazione di conformità
Con questa dichiarazione e con
l’applicazione del marchio CE, il
costruttore Pepperl+Fuchs,
Germania, assicura che il prodotto è
conforme ai regolamenti della
direttiva CEM 89/336/CEE e della
direttiva 94/9/CE. Prova della
conformità è fornita dall’osservanza
degli standard elencati.
Conformiteitsverklaring
De leverancier Pepperl+Fuchs,
Duitsland, waarborgt met deze
verklaring en het aanbrengen van de
CE-markering dat het product
overeenstemt met de voorschriften
van de EMC-richtlijn 89/336/EWG en
de richtlijn 94/9/EG. De
overeenstemming wordt door de
genoemde normen bewezen.
Varmennustodistus
Tällä varmennustodistuksella sekä
CE-merkillä, valmistaja
Pepperl+Fuchs, Saksa, vakuuttaa,
että tuote on direktiivien
EMC 89/336/ETY ja
94/9/EU mukainen. Näyttö
vastaavuudesta on annettu
asiakirjoissa, jotka on listattu
varmennustodistukseen.
Försäkran om överensstämmelse
Pepperl+Fuchs, Tyskland försäkrar
med denna försäkran om
överensstämmelse och med
CE-märkningen att produkten
uppfyller bestämmelserna i
EMC-direktivet 89/336/EEG och
direktiv 94/9/EG.
Överensstämmelsen påvisas genom
givna standarder.
Overensstemmelseserklæring
Med denne overensstemmelses-
erklæring og tilføjelsen af CE-
mærket, sikrer producenten
Pepperl+Fuchs, Tyskland, at
produktet er i overensstemmelse
med bestemmelserne i det EMC-
regulativ 89/336/EEC og Directiv 94/
9/EC. Dokumentation for
overensstemmelsen gives i de
anførte standarder.
Declaração de Conformidade
Com esta Declaração de
Conformidade e o anexo do CE-
Mark, o fabricante Pepperl+Fuchs,
Alemanha, garante que o produto
obedece aos regulamentos da
Directiva EMC 89/336/EEC e
Directiva 94/9/EC. A prova da
conformidade é apresentada
segundo os padrões indicadas.
M’ áõôÞí ôçí ÄÞëùóç
Óõììüñöùóçò êáé ôç óõíçììÝíç
óÞìáíóç CE, o âåâáéþíåé ç
Pepperl+Fuchs, Ãåñìáíßá üôé ôo ðñoúüí
óõììoñöþíåôáé óýìöùíá ìå ôoõò
êáíoíéóìoýò ôçò EõñùðáúêÞò Oäçãßáò
89/336/EOK ðåñß HëåêôñoìáãíçôéêÞò
Óõìâáôüôçôáò êáé ôçí Oäçãßáò
Ðñoóôáóßáò áðü EêñÞîåéò 94/9/EE. Ôo
Aðoäåéêôéêü ôçò Óõììüñöùóçò äßíåôáé
ìÝóù ôùí ðñoôýðùí ðoõ áíáöÝñoíôáé
óôç ÄÞëùóç Óõììüñöùóçò.
da
pt
el
SI 175O-C LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus
SI 175O-C/98/a3/08.05
52027559
FM7.0
187724 08/05 00
Sicherheitshinweise
für elektrische Betriebsmittel
zum Einsatz in explosionsgefährdeten Bereichen
de
Betriebsanleitung
SI 175O-C
52027559
KEMA 05 ATEX 1111
Zugehörige Dokumentation:
BA 238O (PROFIBUS PA)
BA 239O (FOUNDATION Fieldbus)
Ultraschall-Füllstandssensor
LUC-M10, LUC-M20, LUC-M40
F12-Gehäuse, PROFIBUS PA oder
FOUNDATION Fieldbus
Kennzeichnung nach Richtlinie 94/9/EG: II 1/2 G
Gerätegruppe II
Gerätekategorie: Sensor Kategorie 1/Gehäuse Kategorie 2
Für explosionsfähige Atmosphäre durch
Gase, Nebel oder Dämpfe
Kennzeichnung nach Richtlinie 94/9/EG: II 2 G
Gerätegruppe II
Gerätekategorie: Gesamtgerät Kategorie 2
Für explosionsfähige Atmosphäre durch
Gase, Nebel oder Dämpfe
Zuordnung der Gefahrenzone der Montagestelle zur Kategorie der explosions-
geschützten Geräte bzw. Sensoren:
Kennzeichnung der Zündschutzart: EEx ia IIC T3 ... T6
Explosionsgeschütztes elektrisches Betriebsmittel
nach Europanorm
– Zündschutzart
– Betriebsmittelgruppe
– Temperaturklasse
Gefahrenzone an der Montagestelle Kategorie nach Richtlinie 94/9/EG
Gefährdung durch Gase, Nebel oder Dämpfe Zone 0 1G
Gefährdung durch Gase, Nebel oder Dämpfe Zone 1 2G
Gefährdung durch Gase, Nebel oder Dämpfe Zone 2 3G
01020102
0102
2
SI 175O-C LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus
de
Explosionsgefährdeter Bereich
Entsprechend
zugelassener
Abschluss-
widerstand
EEx ia IIC
Zone 1
Behälter
Gefahren-
bereich
Zone 0
Behälter
Gefahren-
bereich
Zone 1
Elektronikeinsatz
für PROFIBUS PA
oder
FOUNDATION
Fieldbus
Potenzialausgleich
Bescheinigtes
zugehöriges
Betriebsmittel
(FISCO-Modell)
Versorgungs-
spannung
Nicht-explosionsgefährdeter Bereich
Bild 1
Elektronikeinsatz
für PROFIBUS PA
oder
FOUNDATION
Fieldbus
Option (ATEX-bescheinigt):
- abgesetzte Anzeige LUC-Z40-Ex1*
- Service-Schnittstelle
EX EX
CR
Explosionsgefährdeter Bereich
Abschluss-
widerstand Verteiler/T-Box Verteiler/T-Box
FeldgerätFeldgerät
Variante 1
Potenzialausgleich in hohem Grade sichergestellt
Nicht-explosionsgefährdeter Bereich
Speisegerät/
Segmentkoppler
Bild 2
EX EX
3
LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus SI 175O-C
de
Bescheinigtes
zugehöriges
Betriebsmittel
Uo=17,5 V oder Uo = 24 V
Io = 500 mA lo = 250 mA
Po = 5,5 W Po = 1,2 W
Elektronikeinsatz:
PROFIBUS PA oder FOUNDATION Fieldbus
FISCO-Modell oder ENTITY-Konzept
(Einzelzusammenschaltung)
[EEx ia] IIC bzw. [EEx ib] IIC
Kategorie II 1/2 G bzw. II 2 G Sensor in Zone 0, Gehäuse Zone 1 bzw.
Sensor und Gehäuse Zone 1
Zündschutzart EEx ia IIC T3 ... T6 KEMA 05 ATEX 1111
Prozessdruck LUC-M10, LUC-M20: max. 0,3 MPa
LUC-M40: max. 0,25 MPa
Prozesstemperatur max. 80 °C
Gehäuse F12 -40 °C Tamb +80 °C wahlweise mit oder ohne Anzeige- und Bedien-
Modul VU 331
Option abgesetzte Anzeige z. B. LUC-Z40-Ex1*
Beachten Sie die EG-Baumusterprüfbescheinigungen, Konformitätsaussagen, Konfor-
mitätserklärungen und Betriebsanleitungen. Diese Informationen finden Sie unter
www.pepperl-fuchs.com.
Service-Schnitt-
stelle z. B. HART-Modem mit Programmiersoftware PACTwareTM
Explosionsgefährdeter Bereich
Abschluss-
widerstand Verteiler/T-Box Verteiler/T-Box
FeldgerätFeldgerät
Variante 2
Potenzialausgleich in hohem Grade sichergestellt
Nicht-explosionsgefährdeter Bereich
Speisegerät/
Segmentkoppler
Bild 3
Schirm isoliert
Kleine Kondensatoren (z. B. 1 nF, 1500 V, Spannungsfestigkeit, Keramik) verwenden.
Gesamte am Schirm angeschlossene Kapazität darf 10 nF nicht übersteigen.
EX EX
C
SI 175O-C LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus
de
SI 175O-C/98/de/08.05
52027559
FM7.0
187724 08/05 00
52027559
Sicherheitshinweise für die Installation in explosionsgefährdeten Bereichen:
1.) Installieren Sie gemäß den Herstellerangaben und den für Sie gültigen Normen und Regeln.
2.) Der eigensichere Eingangsstromkreis des Ultraschallmessgerätes LUC-M10/LUC-M20/LUC-M40 ist erdfrei und mit einer
Spannungsfestigkeit min. 500 Veff gegen Erde ausgeführt.
3.) Der Zusammenhang zwischen zulässiger Umgebungstemperatur für das Elektronikgehäuse in Abhängigkeit
des Einsatzbereiches und der Temperaturklassen ist der Tabelle (Tab. 1) zu entnehmen.
4.) Dauergebrauchstemperatur des Versorgungs-/Signalkabels > Tamb + 5 K.
5.) Erdung des Schirms siehe Bild 2 bzw. Bild 3.
6.) LUC-M40: Elektrostatische Aufladung des Sensors vermeiden (z. B. nicht trocken reiben, außerhalb des Befüllstroms mon-
tieren).
Hinweise (informativ):
7.) Bei der Zusammenschaltung des Messgerätes mit bescheinigten eigensicheren Stromkreisen der Kategorie EEx ib
mit der Explosionsgruppe IIC bzw. IIB ändert sich die Zündschutzart wie folgt: EEx ib IIC bzw. EEx ib IIB.
7.1) Bei der Zusammenschaltung von eigensicheren Stromkreisen sind die Regeln der Zusammenschaltung für eigensichere
Stromkreise zu beachten (DIN EN 60079-14/IEC 60079-14); (Nachweis der Eigensicherheit)
(z. B. bei Verwendung des HART-Modems oder eines Handbediengerätes oder anderer bescheinigter Betriebsmittel)
Tab. 1
Tab. 2
Sicherheitshinweise Zone 0:
8.) Explosionsfähige Dampf-/Luftgemische dürfen nur unter atmosphärischen Bedingungen auftreten:
-20 °C T +60 °C
800 hPa p 1100 hPa
Liegen keine explosionsfähigen Gemische vor oder sind Zusatzmaßnahmen gemäß z. B. EN 1127-1 getroffen, dürfen die
Geräte auch außerhalb der atmosphärischen Bedingungen gemäß ihrer Herstellerspezifikation betrieben werden.
9.) Die Geräte nur in solchen Messstoffen einsetzen gegen die die mediumsberührten Materialien hinreichend beständig sind.
10.) Zugehörige Betriebsmittel mit galvanischer Trennung zwischen eigensicheren und nicht eigensicheren Stromkreisen sind zu
bevorzugen.
Zone 1 - Anwendung
Temperaturklasse Umgebungstemperatur
T6 -40 °C … +60 °C
T5 -40 °C … +75 °C
T4, T3 -40 °C … +80 °C
Versorgungs- und Signalstromkreis in Zündschutzart: Eigensicherheit EEx ia IIC bzw. IIB
LUC-M mit Elektronikeinsatz für PROFIBUS PA oder FOUNDATION Fieldbus
EEx ia IIC: nach FISCO-Modell oder ENTITY-Konzept (Einzelzusammenschaltung)
Höchstwerte:
Ui = 17,5 V
Ii = 500 mA
Pi = 5,5 W
oder Ui=24 V
li= 250 mA
Pi= 1,2 W
Li= 10 µH
Ci=5 nF
Leckstrom < 50 µA
Safety instructions
for electrical apparatus certified
for use in explosion-hazardous areas
en
Operating instructions
SI 175O-C
52027559
KEMA 05 ATEX 1111
Associated documentation:
BA 238O (PROFIBUS PA)
BA 239O (FOUNDATION Fieldbus)
Ultrasonic level sensor
LUC-M10, LUC-M20, LUC-M40
F12 housing, PROFIBUS PA or
FOUNDATION Fieldbus
Designation according to directive 94/9/EC: II 1/2 G
Equipment group II
Equipment category:
sensor category 1/housing category 2
For explosive mixtures composed of gases,
mists or vapours
Designation according to directive 94/9/EC: II 2 G
Equipment group II
Equipment category:
complete unit category 2
For explosive mixtures composed of gases,
mists or vapours
Allocation of hazardous zones at the mounting points to explosion protection
category of the devices or sensors:
Designation of explosion protection: EEx ia IIC T3 ... T6
Electrical apparatus with explosion protection to
European standard
Type of protection
Explosion group
Temperature class
Hazardous zone at the mounting point Category acc. Directive 94/9/EC
Hazard due to explosive gas-air mixtures Zone 0 1G
Hazard due to explosive gas-air mixtures Zone 1 2G
Hazard due to explosive gas-air mixtures Zone 2 3G
01020102
01020102
2
SI 175O-C LUC-M** with PROFIBUS PA or FOUNDATION Fieldbus
en
Explosion-hazardous area Non-hazardous area
Tank
danger
area
Zone 0
Tank
danger
area
Zone 1
Potential
matching system
Fig. 1
Electronic insert
for PROFIBUS PA
or
FOUNDATION
Fieldbus
Electronic insert
for PROFIBUS PA
or
FOUNDATION
Fieldbus
Permitted
terminal
resistor
EEx ia IIC
Certified
associated
apparatus
(e. g. FISCO model) Supply voltage
Zone 1
Option (ATEX-certified):
- Remote display LUC-Z40-Ex1*
- Service interface
EX EX
CR
Hazardous area
High intergrity equipotential bonding must be guaranteed
Fig. 2
Version 1
Terminator Junction box/T-box
Field device
Power supply/
segment coupler
Junction box/T-box
Field device
Non-hazardous area
EX EX
3
LUC-M** with PROFIBUS PA or FOUNDATION Fieldbus SI 175O-C
en
Certified
associated
apparatus
Uo=17.5 V or Uo = 24 V
Io = 500 mA lo = 250 mA
Po = 5.5 W Po = 1.2 W
PROFIBUS PA or FOUNDATION Fieldbus
FISCO-Modell or ENTITY concept
(individual interconnection)
[EEx ia] IIC or [EEx ib] IIC
Category II 1/2 G or II 2 G sensor in zone 0 and housing in zone 1 or
sensor and housing in zone 1
Type of protection EEx ia IIC T3 ... T6 KEMA 05 ATEX 1111
Process pressure LUC-M10, LUC-M20: max. 0.3 MPa
LUC-M40: max. 0.25 MPa
Process temperature max. 80 °C
Housing F12 -40 °C Tamb +80 °C optionally with or without VU 331 display and
operating module
Option remote display e. g. LUC-Z40-Ex1*
EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity
and instructions have to be observed. For information see www.pepperl-fuchs.com.
service interface e. g. HART modem with programming software PACTwareTM
Hazardous area
Fig. 3
Version 2
Field device
Power supply/
segment coupler
Field device
Non-hazardous area
Use small capacitor (e. g. 1 nF, 1500 V, dielectric strength, ceramic).
The total capacitance connected to the screening may not exceed 10 nF.
Isolated screening
High intergrity equipotential bonding must be guaranteed
Terminator Junction box/T-box Junction box/T-box
EX EX
C
SI 175O-C LUC-M** with PROFIBUS PA or FOUNDATION Fieldbus
en
SI 175O-C/98/en/08.05
52027559
FM7.0
187724 08/05 00
52027559
Safety notes for the installation in explosion hazardous areas:
1.) Install according to the manufacturer's instructions and any other valid standards and guidelines.
2.) The intrinsically safe circuit of the LUC-M10/LUC-M20/LUC-M40 ultrasonic sensor is isolated from ground potential and has
a dielectric strength of at least 500 Vrms with respect to it.
3.) The dependency of the permissible ambient temperature of the electronic housing upon the application and temperature
class is given in Tab 1.
4.) Permanent operating temperature of power supply/signal cable > Tamb + 5 K.
5.) For screen grounding, see Fig. 2 or Fig. 3.
6.) LUC-M40: Avoid electrostatic charging of the sensor (e. g. do not rub dry and install outside the filling flow).
Notes (informative):
7.) The type of protection changes as follows when the transmitter is connected to certified intrinsically safe circuits of Category
EEx ib for Group IIC or IIB: EEx ib IIC or EEx ib IIB.
7.1) The pertinent guidelines must be observed when intrinsically safe circuits are connected together
(DIN EN 60079-14/IEC 60079-14); (Proof of Intrinsic Safety).
(e. g. when using a HART modem or a handheld terminal or other certified apparatus).
Tab. 1
Tab. 2
Safety notes for Zone 0:
8.) Potentially explosive vapour/air mixtures may arise under atmospheric conditions only:
-20 °C T +60 °C
800 hPa p 1100 hPa
If no potentially explosive mixtures are present, or if additional protective measures have been taken, acc. to e. g.
EN 1127-1, the transmitters may be operated under other atmospheric conditions in accordance with the manufacturer’s
specifications.
9.) The equipment may only be used in media to be measured where its materials are known to be resistant against the media.
10.) Associated apparatus with galvanic isolation between the intrinsically safe and non-intrinsically safe circuits are to be
preferred.
Zone 1 application
Temperature class Ambient temperature
T6 -40 °C ... +60 °C
T5 -40 °C ... +75 °C
T4, T3 -40 °C ... +80 °C
Power and signal circuits with type of protection: intrinsic safety EEx ia IIC or IIB
LUC-M with electronic insert for PROFIBUS PA or FOUNDATION Fieldbus
EEx ia IIC : as per FISCO-Modell or ENTITY concept (individual interconnection)
Maximum values:
Ui = 17.5 V
Ii = 500 mA
Pi = 5.5 W
or Ui=24 V
li= 250 mA
Pi= 1.2 W
Li= 10 µH
Ci=5 nF
Leakage current < 50 µA
Conseils de sécurité
pour matériels électriques
destinés aux zones explosibles
fr
Mise en service
SI 175O-C
52027559
KEMA 05 ATEX 1111
Documentation correspondante :
BA 238O (PROFIBUS PA)
BA 239O (FOUNDATION Fieldbus)
Détecteur ultrasonique
LUC-M10, LUC-M20, LUC-M40
Boîtier F12, PROFIBUS PA ou
FOUNDATION Fieldbus
Marquage selon directive 94/9/CE : II 1/2 G
Groupe d'appareils II
Catégorie d'appareils :
capteur catégorie 1/boîtier catégorie 2
Pour atmosphère explosive due à la présence de gaz,
brouillards ou vapeurss
Marquage selon directive 94/9/CE : II 2 G
Groupe d'appareils II
Catégorie d'appareils :
appareil complet catégorie 2
Pour atmosphère explosive due à la présence de gaz,
brouillards ou vapeurss
Affectation de la zone dangereuse du point de montage à la catégorie des appareils
ou capteurs avec protection anti-déflagrante :
Marquage du mode de protection : EEx ia IIC T3 ... T6
Matériel électrique antidéflagrant
selon norme européenne
Mode de protection
Groupe d'explosion
Classe de température
Zone dangereuse au point de montage Catégorie selon directive 94/9/CE
Risque dû à la présence de gaz, brouillards ou
vapeurs Zone 0 1G
Risque dû à la présence de gaz, brouillards ou
vapeurs Zone 1 2G
Risque dû à la présence de gaz, brouillards ou
vapeurs Zone 2 3G
0102
0102
2
SI 175O-C LUC-M** avec PROFIBUS PA ou FOUNDATION Fieldbus
fr
Zone explosible
Zone non explosible
Réservoir
Zone 0 Réservoir
Zone 1
Compensation
de potentiel
Fig. 1
Electronique pour
PROFIBUS PA
ou
FOUNDATION
Fieldbus
Electronique pour
PROFIBUS PA
ou
FOUNDATION
Fieldbus
Résistance de
terminaison
agréée
EEx ia IIC
Matériel électrique
certifié associé
(modèle FISCO)
Tension
d’alimentation
Zone 1
Option (Certificat ATEX) :
- Affichage déporté LUC-Z40-Ex1*
- Interface service
EX EX
CR
Zone explosible Zone non explosible
Compensation de potentiel largement assurée
Fig. 2
Variante 1
Résistance de
terminaison
App. de terrain App. de terrain
Alimentation/
coupleur de
segments
Distributeur/T-Box Distributeur/T-Box
EX EX
3
LUC-M** avec PROFIBUS PA ou FOUNDATION Fieldbus SI 175O-C
fr
Matériel électrique associé
certifié Uo=17,5 V ou Uo= 24 V
Io = 500 mA lo = 250 mA
Po = 5,5 W Po= 1,2 W
PROFIBUS PA ou FOUNDATION Fieldbus
Modéle FISCO ou concept ENTITY (connexion
simple) [EEx ia] IIC ou [EEx ib] IIC
Catégorie II 1/2 G ou II 2 G capteur en zone 0, boîtier en zone 1 ou
capteur et boîtier en zone 1
Mode de protection EEx ia IIC T3 ... T6 KEMA 05 ATEX 1111
Pression de process LUC-M10, LUC-M20: max. 0,3 MPa
LUC-M40: max. 0,25 MPa
Temp. de process max. 80 °C
Boîtier F12 -40 °C Tamb +80 °C au choix avec ou sans module d'affichage et de
commande VU 331
Option Affichage déporté par ex. LUC-Z40-Ex1*
Veiller au respect des attestations CE de type, des données de conformité, des
déclarations de conformité et des notices d'instructions. Les informations
correspondantes peuvent être consultées sur notre site Internet www.pepperl-
fuchs.com.
Interface service par ex. HART modem avec logiciel de programmation PACTwareTM
Zone explosible Zone non explosible
Compensation de potentiel largement assurée
Fig. 3
Variante 2
Résistance de
terminaison
App. de terrain App. de terrain
Alimentation/
coupleur de
segments
Distributeur/T-Box Distributeur/T-Box
Utiliser des condensateurs de faible capacité (par ex. 1 nF, 1500 V de rigidité
diélectrique, céramique).
La capacité totale raccordée au blindage ne doit pas dépasser 10 nF.
Blindage isolé
EX EX
C
SI 175O-C LUC-M** avec PROFIBUS PA ou FOUNDATION Fieldbus
fr
SI 175O-C/98/fr/08.05
52027559
FM7.0
187724 08/05 00
52027559
Conseils de sécurité pour l’installation en zones explosibles :
1.) Installer d’après les instructions du fabricant et les normes et règles en vigueur.
2.) Le circuit d'entrée sans sécurité intrinsèque du LUC-M10/LUC-M20/LUC-M40 est isolé galvaniquement de la terre ; il
possède une tenue diélectrique de min. 500 Veff vers la terre.
3.) La relation entre la température ambiante admissible pour le boîtier de l’électronique en fonction de l’application et les
classes de température est indiquée dans le tableau (Tab. 1).
4.) Température de service permanente du câble d'alimentation/de signal > Tamb + 5 K.
5.) Mise à la terre du blindage voir fig. 2 ou fig. 3.
6.) LUC-M40 : Eviter le chargement électrostatique du capteur (par ex. ne pas frotter à sec, installer en dehors de la veine de
produit).
Remarques :
7.) En cas de connexion du transmetteur à des circuits à sécurité intrinsèque certifiés de la catégorie EEx ib pour les groupes
d’explosion IIC ou IIB, le mode de protection se modifie comme suit : EEx ib IIC ou EEx ib IIB.
7.1) Lors de l’interconnexion de circuits à sécurité intrinsèque, il convient de respecter les règles valables en la matière
(DIN EN 60079-14/CEI 60079-14) ; (preuve de la sécurité intrinsèque)
(par ex. lors de l'utilisation du HART modem ou du terminal portable ou d'autres matériels électriques certifiés).
Tab. 1
Tab. 2
Conseils de sécurité zone 0 :
8.) Les mélanges explosibles vapeur/air ne se produisent que sous certaines conditions atmosphérique :
-20 °C T +60 °C
800 hPa p 1100 hPa
En l’absence de mélange explosible ou si des mesures complémentaires selon par ex. EN 1127-1 ont été prises, les
appareils peuvent être utilisés en-dehors des conditions atmosphérique, selon leurs spécifications.
9.) Les appareils ne peuvent être utilisés que dans les produits pour lesquels les matériaux employés sont compatibles.
10.) Les matériels électriques associés avec séparation galvanique entre circuits avec et sans sécurité intrinsèque sont à
préférer.
Zone 1 - Application
Classe de température Température ambiante
T6 -40 °C … +60 °C
T5 -40 °C … +75 °C
T4, T3 -40 °C … +80 °C
Circuit d’alimentation et de signal en mode de protection : sécurité intrinsèque EEx ia IIC ou IIB
LUC-M avec électronique pour PROFIBUS PA ou FOUNDATION Fieldbus
EEx ia IIC : selon modèle FISCO ou concept ENTITY (connexion simple)
Valeurs maximales:
Ui = 17,5 V
Ii = 500 mA
Pi = 5,5 W
ou Ui=24 V
li= 250 mA
Pi= 1,2 W
Li= 10 µH
Ci=5 nF
Courant de fuite < 50 µA
LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus SI 175O-C
SI 175O-C LUC-M** mit PROFIBUS PA oder FOUNDATION Fieldbus
SI 175O-C/98/a3/08.05
52027559
FM7.0
187724 08/05 00
52027559
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Pepperl+Fuchs LUC-M40 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à