Pepperl+Fuchs LVL-M2C Manuel utilisateur

Taper
Manuel utilisateur
de
en
fr
es
it
nl
fi
sv
da
pt
el
Sicherheitshinweise für elektrische Betriebsmittel
zum Einsatz in explosionsgefährdeten Bereichen.
Safety instructions for electrical apparatus certified
for use in explosion-hazardous areas.
Conseils de sécurité pour matériels électriques
destinés aux zones explosibles.
Instrucciones de seguridad de aparatos eléctricos homologados
para su utilización en áreas expuestas a riesgos de deflagración.
Si no entiende este manual, puede pedir un ejemplar en su idioma.
Istruzioni di sicurezza per apparecchiature elettriche certificate
per l'utilizzo in aree con pericolo di esplosione.
Se il presente manuale non risulta comprensibile potete ordinarcene
una copia tradotta nella vostra lingua.
Veiligheidsinstructies voor elektrisch materieel
in explosiegevaarlijke omgeving.
Wanneer u deze handleiding niet kunt lezen, kunt u een in uw
landstaal vertaalde handleiding bij ons bestellen.
Turvallisuusohjeita sähkölaitteille, jotka on vahvistettu
käytettäväksi räjähdysvaarallisilla alueilla.
Jos et ymmärrä tätä käsikirjaa, voit tilata meiltä käännöksen omalla
kansallisella kielelläsi.
Säkerhetsföreskrifter för elektrisk utrustning certifierad
för användning i explosionsfarliga områden.
Om du inte förstår denna manual, kan en översatt kopia på ditt eget
språk beställas från oss.
Sikkerhedsforskrifter for elektriske apparater certificeret
til brug i eksplosionsfarlige områder.
Hvis du ikke forstår denne manual, kan en oversat kopi af den på dit
eget sprog bestilles fra os.
Instruções de segurança para dispositivos eléctricos certificados
para utilização em áreas de risco de incêndio.
Se não compreender este manual, pode encomendar-nos
directamente uma cópia na sua língua.
Oäçãßåò áóöáëåßáò ãéá çëåêôñéêÝò óõóêåõÝò ðoõ åãêñßíoíôáéãéá
÷ñÞóç óå ðåñéo÷Ýò ìå êßíäõío åêñÞîåùí.
Áí äåí ìðoñåßôå íá êáôáíoÞóåôå ôo ðåñéå÷üìåío ôoõ åã÷åéñéäßoõ
áõôoý, ìðoñåßôå íá ðáñáããåßëåôå áðü ôçí åôáéñåßá ìáò Ýíá
áíôßôõðoìåôáöñáóìÝío óôç ãëþóóá óáò.
SI 158O-B
52023703
Code: a3/04.04
KEMA 01 ATEX 1148 X
Vibracon
LVL-M2C mit PROFIBUS PA
fr
es
it
nl
fi
sv
Déclaration de conformité
Par la présente déclaration et par
l’application de la marque CE, le
fabricant Pepperl+Fuchs, Allemagne,
garantit que le produit est conforme
aux prescriptions de la directive CEM
européenne 89/336/CE et de la
directive 94/9/CE. Cette conformité
est attestée par le respect des
normes.
Declaración de conformidad
Por la presente declaración y la
inclusión de la marca CE, el
fabricante Pepperl+Fuchs, Alemania,
garantiza que el producto cumple lo
estipulado por la Directiva
CEM 89/336/CEE y la Directiva
94/9/CE. La prueba de conformidad
se presenta según las normas
expuestas.
Dichiarazione di conformità
Con questa dichiarazione e con
l’applicazione del marchio CE, il
costruttore Pepperl+Fuchs,
Germania, assicura che il prodotto è
conforme ai regolamenti della
direttiva CEM 89/336/CEE e della
direttiva 94/9/CE. Prova della
conformità è fornita dall’osservanza
degli standard elencati.
Conformiteitsverklaring
De leverancier Pepperl+Fuchs,
Duitsland, waarborgt met deze
verklaring en het aanbrengen van de
CE-markering dat het product
overeenstemt met de voorschriften
van de EMC-richtlijn 89/336/EWG en
de richtlijn 94/9/EG. De
overeenstemming wordt door de
genoemde normen bewezen.
Varmennustodistus
Tällä varmennustodistuksella sekä
CE-merkillä, valmistaja
Pepperl+Fuchs, Saksa, vakuuttaa,
että tuote on direktiivien
EMC 89/336/ETY ja
94/9/EU mukainen. Näyttö
vastaavuudesta on annettu
asiakirjoissa, jotka on listattu
varmennustodistukseen.
Försäkran om överensstämmelse
Pepperl+Fuchs, Tyskland försäkrar
med denna försäkran om
överensstämmelse och med
CE-märkningen att produkten
uppfyller bestämmelserna i
EMC-direktivet 89/336/EEG och
direktiv 94/9/EG.
Överensstämmelsen påvisas genom
givna standarder.
Overensstemmelseserklæring
Med denne overensstemmelses-
erklæring og tilføjelsen af CE-
mærket, sikrer producenten
Pepperl+Fuchs, Tyskland, at
produktet er i overensstemmelse
med bestemmelserne i det EMC-
regulativ 89/336/EEC og Directiv 94/
9/EC. Dokumentation for
overensstemmelsen gives i de
anførte standarder.
Declaração de Conformidade
Com esta Declaração de
Conformidade e o anexo do CE-
Mark, o fabricante Pepperl+Fuchs,
Alemanha, garante que o produto
obedece aos regulamentos da
Directiva EMC 89/336/EEC e
Directiva 94/9/EC. A prova da
conformidade é apresentada
segundo os padrões indicadas.
M’ áõôÞí ôçí ÄÞëùóç
Óõììüñöùóçò êáé ôç óõíçììÝíç
óÞìáíóç CE, o âåâáéþíåé ç
Pepperl+Fuchs, Ãåñìáíßá üôé ôo ðñoúüí
óõììoñöþíåôáé óýìöùíá ìå ôoõò
êáíoíéóìoýò ôçò EõñùðáúêÞò Oäçãßáò
89/336/EOK ðåñß HëåêôñoìáãíçôéêÞò
Óõìâáôüôçôáò êáé ôçí Oäçãßáò
Ðñoóôáóßáò áðü EêñÞîåéò 94/9/EE. Ôo
Aðoäåéêôéêü ôçò Óõììüñöùóçò äßíåôáé
ìÝóù ôùí ðñoôýðùí ðoõ áíáöÝñoíôáé
óôç ÄÞëùóç Óõììüñöùóçò.
da
pt
el
SI 158O-B Vibracon LVL-M2C mit PROFIBUS PA
125869 04/04 01
SI 158O-B/98/a3/04.04
52023703
FM7.0
52023703
Sicherheitshinweise
für elektrische Betriebsmittel
zum Einsatz in explosionsgefährdeten Bereichen
de
Betriebsanleitung
SI 158O-B
52023703
KEMA 01 ATEX 1148 X
Zugehörige Dokumentation:
KA 162O
Vibracon
LVL-M2C mit PROFIBUS PA
Kennzeichnung nach Richtlinie 94/9/EG: II 1/2 G
Gerätegruppe II
– Gerätekategorie:
Sensor Kategorie 1/Gehäuse Kategorie 2
Für explosionsfähige Gemische aus
Luft und brennbaren Gasen, Dämpfen oder Nebeln
Allgemeine Erläuterungen zu den Einsatzbereichen:
Kennzeichnung der Zündschutzart: EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
Explosionsgeschütztes elektrisches
Betriebsmittel nach Europanorm
– Zündschutzart
– Betriebsmittelgruppe
– Temperaturklasse
Gerätekategorie Explosionsfähige
Gas-Luft-Gemische (G) Explosionsfähige
Staub-Luft-Gemische (D)
Kategorie 1 Zone 0, 1 oder 2 Zone 20, 21 oder 22
Kategorie 2 Zone 1oder 2 Zone 21 oder 22
Kategorie 3 Zone 2 Zone 22
0102
2
SI 158O-B Vibracon LVL-M2C mit PROFIBUS PA
de
Beachten Sie folgende Installationshinweise:
Installations- und Sicherheitshinweise der Betriebsanleitung beachten.
Gemäß Herstellerangaben und den gültigen Normen und Regeln installieren.
Maximale Prozessbedingungen gemäß zugehöriger Betriebsanleitung des Herstellers beachten. Bei hohen Messstofftempe-
raturen: Druckbelastbarkeit des Flanschs in Abhängigkeit von der Temperatur beachten.
Gerät über geeignete Kabel- und Leitungseinführungen bzw. über Rohrleitungssysteme in der Zündschutzart „Eigensicher-
heit (Ex i)” anschließen.
Zusammenschaltung von eigensicheren PROFIBUS-Geräten: 10 Stück.
Zur Erhaltung der Gehäuseschutzart IP66/IP67 Gehäusedeckel und Kabeleinführungen fachgerecht montieren. Nicht
benutzte Einführungsöffnungen mit geeigneten Verschlussstopfen verschließen.
Verlängerungsrohr des Vibracon LVL-M2C abstützen, wenn dynamische Belastung zu erwarten ist.
Erdung des Schirms siehe Seite 3, Variante 2.
Dauergebrauchstemperatur des Kabels = Tamb + 5 °C.
Bei Zusammenschaltung der Geräte Vibracon LVL-M2C mit dem Elektronikeinsatz für PROFIBUS PA, Typ FEL 50 A (PA), mit
bescheinigten eigensicheren Stromkreisen der Kategorie „ib“, Betriebsmittelgruppe IIC bzw. IIB, ändert sich die Zündschutz-
art wie folgt: EEx ib IIC T6 bzw. EEx ib IIB T6.
Zuordnung der Umgebungstemperaturen und Prozesstemperaturen zu den Temperaturklassen der Tabelle auf Seite 4 ent-
nehmen.
PROFIBUS PA Foundation Fieldbus
Bescheinigtes
zugehöriges
Betriebsmittel
Ui17,5 V
Ii 500 mA
Pi 5,5 W
Li= 51 µH, Ci= 0
Ui24 V
Ii 250 mA
Pi 1,2 W
Li= 51 µH, Ci= 0
[EEx ia] IIC bzw. [EEx ib] IIC
Zündschutzart Kategorie für Vibracon, Typ:
EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
mit Warnhinweis
II 1/2 G LVL-M2C mit Beschichtung aus Email oder nichtleitendem PFA
Explosionsgefährdeter Bereich
Entsprechend
zugelassener
Abschluss-
widerstand
EEx ia IIC
Behälter
Gefahren-
bereich
Zone 0
Behälter
Gefahren-
bereich
Zone 1
Elektronikeinsatz
für
PROFIBUS PA
für
PROFIBUS PA
Elektronikeinsatz
Potenzialausgleich
Bescheinigtes
zugehöriges
Betriebsmittel
Versorgungs-
spannung
Nicht-explosionsgefährdeter Bereich
EX EX
CR
Zone 1
3
Vibracon LVL-M2C mit PROFIBUS PA SI 158O-B
de
Explosionsgefährdeter Bereich
Abschluss-
widerstand Verteiler/T-Box Verteiler/T-Box
FeldgerätFeldgerät
Variante 1
Potenzialausgleich in hohem Grade sichergestellt
Nicht-explosionsgefährdeter Bereich
Speisegerät/
Segmentkoppler
EX EX
Explosionsgefährdeter Bereich
Abschluss-
widerstand Verteiler/T-Box Verteiler/T-Box
FeldgerätFeldgerät
Variante 2
Potenzialausgleich in hohem Grade sichergestellt
Nicht-explosionsgefährdeter Bereich
Speisegerät/
Segmentkoppler
Schirm isoliert
(kapazitiv geerdet)
Kleine Kondensatoren (z. B. 1 nF, 1500 V, Spannungsfestigkeit, Keramik) verwenden.
Gesamte am Schirm angeschlossene Kapazität darf 10 nF nicht übersteigen.
EX EX
C
SI 158O-B Vibracon LVL-M2C mit PROFIBUS PA
de
SI 158O-B/98/de/04.04
52023703
FM7.0
125869 04/04 01
52023703
Applikationstabelle für Temperaturbereiche:
Die mit nichtleitenden Kunststoffen beschichteten Sensoren sind für den Einsatz in der Gasgruppe IIC geeignet, wenn sicher-
gestellt wird, dass elektrostatische Aufladungen der Sensoren (z. B. Reibung, Reinigung, Wartung, starke Medienströme usw.)
vermieden werden. Diese Sensoren sind mit dem Warnschild „Elektrostatische Aufladung vermeiden!“ kenntlich gemacht.
Sicherheitshinweise Zone 0:
Von dem für die Zone 0 zugelassenen Sensorteil des Vibracon LVL-M2C gehen auch dann keine Zündgefahren aus, wenn
es unter nicht-atmosphärischen Drücken und nicht-atmosphärischen Temperaturen betrieben wird.
Für den bestimmungsgemäßen Betrieb zulässige Messstofftemperaturen:
abhängig von der Umgebungstemperatur; siehe Tabelle und Temperaturgrafik.
Für den bestimmungsgemäßen Betrieb zulässige Drücke:
pe = -1 bar … +64 bar, abhängig vom Prozessanschluss; siehe Betriebsanleitung des Herstellers.
Die Geräte nur in solchen Messstoffen einsetzen, gegen die die mediumsberührten Materialien hinreichend beständig sind
(insbesondere die Prozessanschlussdichtung).
Typ Temperaturklasse Messstofftemperatur
(Sensor) Umgebungstemperatur
(Elektronik)
LVL-M2C (ECTFE- oder PFA-Beschichtung) T6 -50 °C ... +85 °C -50 °C ... +70 °C
LVL-M2C (ECTFE- oder PFA-Beschichtung) T5 -50 °C ... +100 °C -50 °C ... +70 °C
mit Temperaturdistanzstück;
ohne Temperaturdistanzstück
siehe folgendes Diagramm
LVL-M2C (ECTFE-Beschichtung) T4 -50 °C ... +120 °C -50 °C ... +70 °C
mit Temperaturdistanzstück;
ohne Temperaturdistanzstück
siehe folgendes Diagramm
LVL-M2C (PFA-Beschichtung) T4 -50 °C ... +135 °C -50 °C ... +70 °C
mit Temperaturdistanzstück;
ohne Temperaturdistanzstück
siehe folgendes Diagramm
LVL-M2C (PFA-Beschichtung) T3 -50 °C ... +150 °C -50 °C ... +70 °C
mit Temperaturdistanzstück;
ohne Temperaturdistanzstück
siehe folgendes Diagramm
* zusätzlich nutzbarer Temperaturbereich für Geräte mit Temperaturdistanzstück
oder druckdichter Durchführung
T1
T2
70 ˚C
T1
50 ˚C
60 ˚C
0 ˚C
-50 ˚C
-50 ˚C
0 ˚C 50 ˚C
*
100 ˚C
ECTFE
PFA
120 ˚C
150 ˚C T2
90 ˚C
Safety instructions
for electrical apparatus certified
for use in explosion-hazardous areas
en
Operating instructions
SI 158O-B
52023703
KEMA 01 ATEX 1148 X
Associated documentation:
KA 162O
Vibracon
LVL-M2C with PROFIBUS PA
Designation according to dir. 94/9/EC: II 1/2 G
Equipment group II
Equipment category:
sensor category 1/housing category 2
For explosive mixtures of air
and combustible gases, vapours or mists
General descriptions of the areas of application:
Designation of explosion protection: EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
Electrical apparatus with explosion protection to
European standard
Type of protection
Apparatus group
Temperature class
Equipment gategory Explosive
gas-air mixtures (G) Explosive
dust-air mixtures (D)
Category 1 zone 0, 1 or 2 zone 20, 21 or 22
Category 2 zone 1or 2 zone 21 or 22
Category 3 zone 2 zone 22
0102
2
SI 158O-B LVL-M2C with PROFIBUS PA
en
Please note the following installation instructions:
Comply with the installation and safety instructions in the operating instructions.
Install the device according to the manufacturer’s instructions and any other valid standards and regulations.
Pay attention to the maximum process conditions according to the manufacturer’s operating instructions. At high medium
temperatures: note flange pressure load capacity as a factor of temperature.
Connect the instrument using suitable cable and line entries or via pipeline systems of protection type "Instrinsic safety (Ex i)".
Connection of intrinsically safe PROFIBUS devices: 10 devices.
To maintain the ingress protection IP66/IP67 of the housing, install the housing cover and cable glands correctly. Close off
any unused entries with suitable plugs.
Support extension tube of Vibracon LVL-M2C if a dynamic load is expected.
Grounding the screen, see page 3, version 2.
Long-term service temperature for the cable = Tamb + 5 °C.
When the Vibracon LVL-M2C with electronic insert for PROFIBUS PA, model FEL 50 A (PA) devices with certified intrinsically
safe power circuits in category "ib", equipment group IIC or IIB are connected together, the degree of protection changes as
follows: EEx ib IIC T6 or EEx ib IIB T6.
The dependency of the ambient and process temperatures upon the temperature class can be found in the table on page 4.
PROFIBUS PA Foundation Fieldbus
Certified
associated
apparatus
Ui17.5 V
Ii 500 mA
Pi 5.5 W
Li= 51 µH, Ci= 0
Ui24 V
Ii 250 mA
Pi 1.2 W
Li= 51 µH, Ci= 0
[EEx ia] IIC or [EEx ib] IIC
Type of protection Category for Vibracon, type:
EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
with warning information
II 1/2 G LVL-M2C with coating of ECTFE or non-conductive PFA
Hazardous area Non-hazardous area
Container
hazardous
area
Zone 0
Container
hazardous
area
Zone 1
Potential equalisation
Electronic insert
for
PROFIBUS PA
Electronic insert
for
PROFIBUS PA
Corresponding
approved
terminal
resistance
EEx ia IIC
Certified
relevant operating
equipment Power supply
EX EX
CR
Zone 1
3
LVL-M2C with PROFIBUS PA SI 158O-B
en
Hazardous area
Potential equalisation ensured to a high degree
Version 1
Terminal
resistance Distributor/T-box
Field device
Power supply unit/
segment coupler
Distributor/T-box
Field device
Non-hazardous area
EX EX
Hazardous area
Potential equalisation ensured to a high degree
Version 2
Terminal
resistance Distributor/T-box
Field device
Power supply unit/
segment coupler
Distributor/T-box
Field device
Non-hazardous area
Use small capacitor (e. g. 1 nF, 1500 V, dielectric strength, ceramic).
Total capacity connected to the screen must not exceed 10 nF.
Screen insulated
(capacitively grounded)
EX EX
C
SI 158O-B Vibracon LVL-M2C with PROFIBUS PA
en
SI 158O-B/98/en/04.04
52023703
FM7.0
125869 04/04 01
52023703
Application table for temperature ranges:
Sensors coated with non-conductive materials are suitable for use in gases of group IIC if there is no electrostatic charging of
the sensors (e.g. friction, cleaning, maintenance, strong currents etc.). These sensors are indicated by the warning sign "Avoid
electrostatic charge!".
Safety notes for zone 0:
The sensor part of Vibracon LVL-M2C approved for zone 0 does not cause any ignition hazards if it is operated under non-
atmospheric pressures and temperatures.
Permissible medium temperatures for operation in accordance with manufacturer’s specifications:
dependent on ambient temperature; see table and temperature graphics.
Permissible pressures for operation in accordance with manufacturer’s specifications:
pe = -1 bar ... +64 bar, dependent on process connection; see manufacturer’s operating instructions.
The transmitters may be employed only in those media, for which the wetted parts (in particular the process connection seal)
are known to be suitable.
Type Temperature class Fluid temperature
(sensor) Ambient temperature
(electronics)
LVL-M2C (ECTFE or PFA coating) T6 -50 °C ... +85 °C -50 °C ... +70 °C
LVL-M2C (ECTFE or PFA coating) T5 -50 °C ... +100 °C -50 °C ... +70 °C
with temperature spacer;
without temperature spacer
see figure below
LVL-M2C (ECTFE coating) T4 -50 °C ... +120 °C -50 °C ... +70 °C
with temperature spacer;
without temperature spacer
see figure below
LVL-M2C (PFA coating) T4 -50 °C ... +135 °C -50 °C ... +70 °C
with temperature spacer;
without temperature spacer
see figure below
LVL-M2C (PFA coating) T3 -50 °C ... +150 °C -50 °C ... +70 °C
with temperature spacer;
without temperature spacer
see figure below
* additional temperature range for sensors with temperature spacer or
pressure-tight bushing
T1
T2
70 ˚C
T1
50 ˚C
60 ˚C
0 ˚C
-50 ˚C
-50 ˚C
0 ˚C 50 ˚C
*
100 ˚C
ECTFE
PFA
120 ˚C
150 ˚C T2
90 ˚C
Conseils de sécurité
pour matériels électriques
destinés aux zones explosibles
fr
Mise en service
SI 158O-B
52023703
KEMA 01 ATEX 1148 X
Documentation complémentaire :
KA 162O
Vibracon
LVL-M2C avec PROFIBUS PA
Marquage selon directive 94/9/CE : II 1/2 G
Groupe d'appareils II
Catégorie d'appareils :
capteur catégorie 1/boîtier catégorie 2
Pour mélanges explosifs d'air et de
gaz, vapeurs et brouillards inflammables
Explications générales relatives aux domaines d’application:
Marquage du mode de protection : EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
Matériel électrique protégé contre les explosions
selon norme européenne
Mode de protection
Groupe d'appareils
Classe de température
Catégorie d’appareils Mélanges explosifs
gaz - air (G) Mélanges explosifs
poussières - air (D)
Catégorie 1 zone 0, 1 ou 2 zone 20, 21 ou 22
Catégorie 2 zone 1ou 2 zone 21 ou 22
Catégorie 3 zone 2 zone 22
01020102
2
SI 158O-B Vibracon LVL-M2C avec PROFIBUS PA
fr
Tenir compte des conseils d’installation suivants :
Tenir compte des conseils d’installation et de sécurité du manuel de mise en service.
Installer d’après les instructions du fabricant et les normes et règles en vigueur.
Tenir compte des conditions de process maximales en fonction du manuel de mise en service correspondant du fabricant.
Dans le cas de températures élevées : tenir compte de la résistance à la pression de la bride en fonction de la température.
Racorder l’appareil à l’aide d’entrées de câbles ou de systèmes de conduites appropriés en mode de protection "Sécurité
intrinsèque (Ex i)".
Connexion d’appareils PROFIBUS à sécurité intrinsèque : 10 pièces.
Pour garantir le maintien du mode de protection du boîtier IP66/IP67, monter le couvercle du boîtier et les entrées de câble
dans les règles de l’art. Occulter les entrées de câbles non utilisées à l’aide de bouchons appropriés.
Arrimer le tube prolongateur du Vibracon LVL-M2C si une contrainte dynamique est à pvoir.
Mise à la terre du blindage voir page 3, variante 2.
Température d’utilisation permanente du câble = Tamb + 5 °C.
En cas de connexion des appareils Vibracon LVL-M2C et électronique pour PROFIBUS PA, Type FEL 50 A (PA), à des circuits
à sécurité intrinsèque certifiés de la catégorie "ib", groupe d’appareils IIC ou IIB, le mode de protection se modifie comme
suit : EEx ib IIC T6 ou EEx ib IIB T6.
L’attribution des températures ambiantes et de process aux classes de température est reprise dans la tableau à la page 4.
PROFIBUS PA Foundation Fieldbus
Matériel électrique associé
certifié Ui 17,5 V
Ii 500 mA
Pi 5,5 W
Li = 51 µH, Ci = 0
Ui 24 V
Ii 250 mA
Pi 1,2 W
Li = 51 µH, Ci = 0
[EEx ia] IIC ou [EEx ib] IIC
Mode de protection Catégorie pour Vibracon, Type:
EEx ia IIC T3 ... T6
EEx ib IIC T3 ... T6
avec avertissement
II 1/2 G LVL-M2C avec revêtement en ECTFE ou PFA non conducteur
Zone explosible
Zone non explosible
Réservoir
Zone 0 Réservoir
Zone 1
Compensation de potentiel
Electronique d’après
pour
PROFIBUS PA
Electronique d’après
pour
PROFIBUS PA
Résistance de
terminaison
admise
EEx ia IIC
Matériel électrique
certifié associé Tension d’ali-
mentation
EX EX
CR
Zone 1
3
Vibracon LVL-M2C avec PROFIBUS PA SI 158O-B
fr
Zone explosible Zone non explosible
Compensation de potentiel largement assurée
Variante 1
Résistance de
terminaison
App. de terrain App. de terrain
Alimentation/
coupleur de
segments
Distributeur/T-Box Distributeur/T-Box
EX EX
Zone explosible Zone non explosible
Compensation de potentiel largement assurée
Variante 2
Résistance de
terminaison
App. de terrain App. de terrain
Alimentation/
coupleur de
segments
Distributeur/T-Box Distributeur/T-Box
Utiliser des petits condensateurs (par ex. 1 nF, 1500 V, résistance, céramique).
La capacité totale raccordée au blindage ne doit pas dépasser 10 nF.
Blindage isolé
(mise à la terre capacitive)
EX EX
C
SI 158O-B Vibracon LVL-M2C avec PROFIBUS PA
fr
SI 158O-B/98/fr/04.04
52023703
FM7.0
125869 04/04 01
52023703
Tableau d’applications pour gammes de température :
Les capteurs qui sont revêtus de matières synthétiques non conductices sont concus pour une utilisation dans le groupe de gaz
IIC, s’il est garanti que tout chargement électrostatique des capteurs (par ex. friction, nettoyage, maintenance, courants de
produit forts, etc.) est évité. Ces capteurs sont marqués à l’aide d’une plaque portant la mention "Elektrostatische Aufladung
vermeiden!" ("Eviter tout chargement électrostatique!").
Conseils de sécurité zone 0 :
La partie capteur du Vibracon LVL-M2C agrée pour la zone 0 n’est à l’origine d’aucun risque d’allumagemême si elle est
utilisée avec des pressions et températures non atmosphériques.
Températures du produit admissibles pour une utilisation conforme à l’objet :
en fonction de la température ambiante; voir tableau et graphiques de température.
Pressions admissibles pour une utilisation conforme à l’objet :
pe = -1 bar ... +64 bar, en fonction du raccord process; voir manuel de mise en service du fabricant.
Les appareils ne peuvent être utilisés que dans les produits pour lesquels les matériaux employés (en particulier les joints
des raccords process) sont compatibles.
Type Classe de température Température du produit
(capteur) Température ambiante
(electronique)
LVL-M2C (revêtement ECTFE, PFA) T6 -50 °C ... +85 °C -50 °C ... +70 °C
LVL-M2C (revêtement ECTFE, PFA) T5 -50 °C ... +100 °C -50 °C ... +70 °C
avec réducteur thermique;
sans réducteur thermique voir
graphique des témperatures suivant
LVL-M2C ((revêtement ECTFE) T4 -50 °C ... +120 °C -50 °C ... +70 °C
avec réducteur thermique;
sans réducteur thermique voir
graphique des témperatures suivant
LVL-M2C (revêtement PFA) T4 -50 °C ... +135 °C -50 °C ... +70 °C
avec réducteur thermique;
sans réducteur thermique voir
graphique des témperatures suivant
LVL-M2C (revêtement PFA) T3 -50 °C ... +150 °C -50 °C ... +70 °C
avec réducteur thermique;
sans réducteur thermique voir
graphique des témperatures suivant
* Gamme de température utile supplémentaire pour appareils avec
réducteur thermique ou entrée résistant à la pression
T1
T2
70 ˚C
T1
50 ˚C
60 ˚C
0 ˚C
-50 ˚C
-50 ˚C
0 ˚C 50 ˚C
*
100 ˚C
ECTFE
PFA
120 ˚C
150 ˚C T2
90 ˚C
Vibracon LVL-M2C mit PROFIBUS PA SI 158O-B
SI 158O-B Vibracon LVL-M2C mit PROFIBUS PA
SI 158O-B/98/a3/04.04
52023703
FM7.0
125869 04/04 01
52023703
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Pepperl+Fuchs LVL-M2C Manuel utilisateur

Taper
Manuel utilisateur