Baumer PBMN high pressure Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

2/4
Instructions de montage
General notes:
Rules for proper usage
This product is a precision device which has been
designed for the detection of pressures. It generates and
provides measured values issued as electrical
signals for following systems. Unless this product has not
been specifically marked it may not be used in hazardous
areas.
Set-up
Installation, mounting and adjustment of this product may
only be executed by skilled employees.
Allgemeine Hinweise:
Bestimmungsgemässer Gebrauch
Dieses Produkt ist ein Präzisionsgerät und dient zur
Erfassung von Drücken und der Aufbereitung bzw.
Bereitstellung von Messwerten als elektrische Grösse für
das Folgesystem.
Sofern dieses Produkt nicht speziell gekennzeichnet ist,
darf dieses nicht für den Betrieb in explosionsgefährdeter
Umgebung eingesetzt werden.
Inbetriebnahme
Einbau, Montage und Justierung dieses Produktes dürfen
nur durch eine Fachkraft erfolgen.
Indications d’ordre général:
Affectation
Ce produit est un appareil de précision. Il sert à la
détection de pressures, ainsi qu’au traitement et à la
transmission de valeurs de mesure sous forme d’une
grandeur électrique. Si ce produit n’est pas spécialement
désigné, il ne peut être utilisé dans des environnements
présentant un risque d’explosion.
Mise en service
L’installation, le montage et le réglage de ce produit ne
peut être effectué que par une personne spécialisée.
11092230 / P95.4007 H / 04.05.2018
Installation hints
4.
Mai
.
2018
15:22
ralités
Malgré sa robustesse, le PBMN ne doit pas subir de chocs violents. Evitez les surpressions statiques ou dynamiques dépassant les valeurs indiquées dans la notice technique.
S’il y a des raccords affleurants, une membrane ondulée, très sensible, est à découvert. Pour ne pas endommager la membrane, évitez l’utilisation et le nettoyage avec des produits abrasifs et le contact avec
des corps fermes (même les doigts). N’enlevez donc le capot protecteur que peu avant l’installation du transmetteur. Laissez le cap de protection et montez le de nouveau pour le stockage ou le transport du
transmetteur. Pièces en contact avec les médias: connexion de membrane et de processus
Montage sur le système de pression
Le transmetteur de pression possède des goupilles filetées ou filets femelles pour le raccord. Dans la plupart de cas, les joints ne sont pas fournis. Utilisez des joints adaptés à la pression et au produit. Pour les
joints métalliques, il est conseillé de lubrifier la surface d’étanchéité avec de la graisse à base de MoS2 ou de vaseline.
Pour le montage, utilisez une clé appropriée. Le couple de serrage M ne doit pas être dépassé, pour le montage.
Les modèles dotés d’un refroidisseur (T produit = 200°C) doivent être installés dans un angle maximal de 10° par rapport à l’horizontale, pour que le refroidisseur fonctionne correctement (cf. croquis page 1).
Raccord électrique
Raccordez le transmetteur de pression suivant le croquis ci-dessus. Veillez à la bonne polarité et utilisez des câbles blindés. Le coffret du transmetteur et le blindage des câbles doivent être mis à la terre. La
jonction du blindage du côté de la commande doit être connecté a une grande zone, pour obtenir la meilleure protection possible contre les interférences électromagnétiques. Pour les modèles avec une
enveloppe pour le champ, le blindage des câbles doit être réparti régulièrement sur la surface de contact.
Dans la mesure du possible, évitez les différences de potentiel entre le coffret du transmetteur et la commande. Pour satisfaire aux exigences TBTP selon la norme EN60204-1 § 6.4.1, le haut voltage (GND)
doit être raccordé avec la terre de protection, à un endroit du système.
Ex - Utilisation en atmosphère explosive
Le PBMN doit être exploité en tenant compte des directives en vigueur pour zone 0 ou 1,
respectivement zone 20 ou 21 et en utilisant une barrière Zener certifiée et intrinsèque.
(représentation schématique v. schéma de raccordement, caractéristiques barrière Zener,
resp. valeurs d’entrée intrinsèques v. page 4).
General information
Despite its robust design, the PBMN must not be exposed to severe impacts. Avoid static or dynamic overpressure exceeding the values specified in the datasheet.
With connections flush with the front panel, a corrugated, highly sensitive membrane is exposed. To ensure that the membrane is not damaged, avoid using and cleaning with abrasive agents, and avoid
touching it with solid bodies (including fingers). For this reason, do not remove the protective cap until shortly before the installation of the transmitter. Keep the protective cap and mount it again for storage or
transportation of the transmitter. Media contacting parts: membrane and process connection
Installation in the pressure system
For connection purposes, the pressure transmitter has threaded ends or internal threads. In most cases, no seal is included in the scope of delivery. Use seals suitable for the pressure and the medium. If the
seal is a metallic seal, it is recommended that the sealing surface should be lubricated with grease on an MoS2 or vaseline basis.
Use a suitable wrench for installation. The tightening torque M must not be exceeded in the course of installation.
Types with a cooling line (TMedium = 200°C) must be installed at a maximum angle of 10° to the horizontal for the cooling to function correctly (see sketch on page 1).
Electrical connection
Connect the pressure transmitter in accordance with the above sketch. Ensure that polarity is correct and use shielded cables. The transmitter housing and the cable shield must be grounded. Keep the
connection of the shield on the controller side with a large contact area to achieve the best possible protection from electromagnetic interference. In types with field housings, the cable shield is to to be
distributed evenly on the contact surface of the cable gland.
As far as possible, prevent potential differences between the housing of the transmitter and the controller. To comply with the PELV requirements in accordance with EN60204-1 §6.4.1, 0V (GND) must be
connected to a point in the system with protective grounding.
Ex-applikation
The PBMN must be installed in accordance with prevailing guidelines for zone 0 or 1
respectively zone 20 or 21 and a certified, intrinsically safe zener barrier must be used.
(see schematic „Connection diagrams“ (see page 1), data for the zener barrier
respectively intrinsic input values, (see page 4)).
Ex- configuring
FlexProgrammer 9701 must not be connected within the hazardous area.
Configuring procedure:
a) Disconnect the
PBMN
from the circuit within the hazardous area.
b) Bring the
PBMN
to the safe area
c) Connect the Flex Programmer and configure the
PBMN
.
d) Re-Install the
PBMN
in the hazardous area
e) Re- connect the signal cable.
Ex- Configuration du PBMN
Le FlexProgrammer 9701 permettant la configuration du
PBMN
ne doit pas être
connecté, ni utilisé en atmosphère explosive. Pour configurer le
PBMN
,
procédez comme suit:
a) Débranchez le
PBMN
de son alimentation électrique
b) Amenez le
PBMN
en atmosphère non explosive
c) Connectez le
PBMN
au FlexProgrammer et configurez le
d) Après configuration, ramenez le en atmosphère explosive
e) Branchez le à nouveau
3/4
EG-Baumusterprüfbescheinigung
EC-type-examination Certificate
Certificat de contrôle EG
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
11092230 / P95.4007 H / 04.05.2018
4.
Mai
.
2018
15:22
Sicherheits- Angaben PBMN
Dieses Gerät wurde gemäss den aktuell gültigen EU Richtlinien gebaut, getestet und unter
technisch sicheren Bedingungen verpackt. Um diesen Zustand aufrecht zu halten und
einen sicheren Betrieb zu gewährleisten, müssen die Angaben und Warnungen, welche in
dieser Anleitung aufgelistet sind, beachtet werden.
Für den Einbau müssen die national geltenden Normen beachtet und eingehalten werden.
Dieses Produkt muss von instruiertem Fachpersonal bedient werden. Der richtige und
sichere Einsatz hängt von richtigem Transport, Lagerung, Einbau und Betrieb des Produkts
ab.
Der elektrische Anschluss muss gemäss den am Einbauort geltenden Bestimmungen
vorgenommen werden. Um Signalstörungen zu vermeiden, empfehlen wir den Einsatz von
geschirmten Kabeln. Weiter sollen Speisekabel örtlich getrennt zur Signalleitung verlegt
werden. Die Verdrahtung muss gemäss elektrischem Anschlussplan ausgeführt werden.
Bevor Sie die Stromersorgung einschalten, stellen Sie sicher, dass keine anderen Anlagen-
teile dadurch beeinflusst werden. Stellen Sie sicher, dass die Speisespannung und die
Umgebungsbedingungen der Produktspezifikationen entsprechen.
Bevor Sie die Stromversorgung ausschalten, prüfen Sie die möglichen Auswirkungen auf
andere Anlagenteile oder Systeme.
WARNUNG
Ein Nichtbefolgen der folgenden Warnungen kann zum Tod oder schweren Ver-
letzungen von Personen oder zu grossen Schäden an Material oder Einrichtung
führen.
Für elektrische Installation und Inbetriebnahme von explosionsgeschützten Produkten
müssen die aufgeführten Daten, die Anforderungen nach EN 60079-14 und die lokal
geltenden Richtlinien für die Installation von elektrischen Geräten innerhalb explosionsge-
schützten Umgebungen beachtet werden. Die eigensicheren Versionen können in
explosionsgefährdeten Zonen gemäss ihren Spezifikationen eingesetzt werden.
WARNUNG
Dieses Produkt enthält keine austauschbaren Teile. Bei einer Fehlfunktion muss das
Produkt zur Reparatur zu Baumer zurückgesendet werden.
WARNUNG
Achtung! Für Anwendungen als Betriebsmittel der Kategorie 1 (EPL Ga) Gruppe IIC sind
gefährliche elektrostatische Aufladungen an der Oberfläche der Schutzkappe und entlang
des Kabelmantels zu vermeiden (z. B. durch schnelle Füllungen und Entleerungen von
Behältern oder andere mechanische Reibvorgänge).
Nach Einbau und Anschluss - prüfen Sie, dass das Gehäusepotential auf dem Erdpotential
liegt.
Die Druckmessumformer können in die Grenzwand montiert werden, die den Bereich mit
Kategorie 1 (EPL Ga) - Anforderungen (Zone 0) von dem mit Kategorie 2 (EPL Gb) -
Anforderungen (Zone 1) trennt. Dabei muss der Prozessanschluss nach EN 60079-26,
Abschnitt 4.6 ausreichend dicht sein z.B. durch Einhaltung der Schutzart IP67 nach
EN60529. Die Messzelle darf nur für brennbare Stoffe verwendet werden, für die die
Membranen der Messzellen hinreichend chemisch und gegen Korrosion beständig sind.
Hinweis
Die Druckmessumformer PBMN sind so spezifiziert bzw. bemessen, dass diese vollständig
in Staub eingeschüttet verwendet werden können.
!
!
!
Safety Instructions PBMN
This instrument is built and tested according to the current EU-directives and packed in
technically safe condition. In order to maintain this conditionand to ensure safe operation,
the user must follow the hints and warnings given in this instruction.
During the installation the valid national rules have to be observed.
The product must be operated by trained staff. Correct and safe operation of this
equipment is dependent on proper transport, storage, installation and operation.
All electrical wiring must conform to local standards. In order to prevent stray electrical
radiation, we recommend shielded input cables, as also to keep power supply cables
separated from the input cables. The connectionmust be made according to the
connecting diagrams.
Before switching on the power supply take care that other equipment is not affected.
Ensure that the supply voltage and the conditions in the environment comply with the
specification of the device.
Before switching off the supply voltage check the possible effects on other equipment and
the processing system.
WARNING
Ignoring the following warnings may lead to severe personal injury or substantial
damage to property.
For electrical installation and commissioning of explosion protected devices, the given
data, the requirements to EN 60079-14 as also the local regulations for installation of
electrical apparatus within explosion protected areas must be considered. The intrinsically
safe versions can be used in explosive areas according to their specifications.
WARNING
This product contains no replaceable parts. In case of malfunction the product must be
shipped to Baumer for repair.
WARNING
Attention! For applications as an equipment of category 1 (EPL Ga) group IIC avoid
dangerous electrostatic charge on the surface of the protection cap and along the cable
jacket (e.g. quick filling or emptying of tanks or other mechanical friction procedures)
After the mounting:
Check if the case is connected with the ground potential.
The pressure transmitters can be mounted in boundary walls, which separates the areas
according to category 1 (EPL Ga) - requirements (zone 0) from areas according to
category 2 (EPL Gb) - requirements (zone 1). In this case, the process connection must be
sufficiently sealed according to EN 60079-26, art. 4.6, e.g. the protection class IP67
according to EN 60529.
The measuring cell may only be used for inflammable substances for those the
diaphragms are steady enough against chemical and corrosive influences.
Advice
The pressure transmitters PBMN are specified and designed that they can be used fully
covered with dust.
Instruction decurité PBMN
Cet instrument de mesure a été conçu et testé conformément aux directives européennes
en vigueur. Afin de garantir un fonctionnement en toute sécurité, il est indispensable que
les données et les avertissements de cette instruction soient respectés.
Il est à noter que les règles nationales en vigueur sont également à respecter.
Cet instrument ne doit être manipulé et utilisé que par du personnel instruit. Un
fonctionnement correct et sûr dépend également des conditions de transport, de stockage,
de montage et de mise en fonction ainsi que d’utilisation de l’instrument.
Le raccordement électrique doit être également conforme aux conventions locales en
vigueur. Afin d’éviter tout perturbation du signal de l’instrument, nous recommandons
l’usage de câble blindés. De plus il est recommandé de séparé physiquement les câbles
d’alimentation du système des câble de mesures. Le câblage doit être conforme au
schéma de raccordement électrique.
Avant de mettre l’appareil sous tension, vérifiez qu’aucun autre équipement ne puisse en
être affecter. Et vérifiez que la tension d’alimentation et les conditions ambiantes
correspondent aux spécifications de cet appareil.
De même, avant de mettre l’appareil hors tension, vérifiez qu’aucun autre équipement ne
puisse en être affecter.
AVERTISSEMENT
Le non respect des avertissements ci-après peut causer des blessures graves allant
jusqu’à la mort ainsi que dests mariels importants.
Pour l’installation électrique ainsi que pour la mise en service d’appareils protégés contre
les explosions, il faut absolument respecter les données techniques indiquées ainsi que les
exigences selon EN 60079-14 mais aussi les instructions locales en vigueur pour le
montage d’appareils électriques en milieux explosifs. Les versions intrinsèques peuvent
être utilisées en milieux explosifs conformément à leurs spécifications.
AVERTISSEMENT
Cet appareil ne contient pas de pièce interchangeables. En cas de disfonctionnement,
l’appareil doit être envoyé à Baumer pour réparation.
AVERTISSEMENT
Attention! Pour des applications comme moyen de production de la catégorie 1(EPL Ga)
Groupe IIC, les charges électrostatiques dangereuses sur la surface du capuchon
protecteur et le long de la gaine du câble sont à éviter (p.ex., lors des remplissages ou des
vidanges rapides des réservoirs ou d’autres processus de friction mécaniques).
Après le montage et le raccordement, contrôlez si le boîtier est bien raccordé avec le
potentiel de la terre.
Les transmetteurs de pression peuvent être montés dans le mur de délimitation qui sépare
le domaine de la catégorie 1 (EPL Ga) – Exigences (Zone 0) de celui de la catégorie (EPL
Gb) - Exigences (Zone 1). Dans ce cas, la connexion du process selon EN 60079-26,
Paragraphe 4.6 doit être suffisamment étanche comme, par exemple, en conformité avec
la classe de protection IP67 selon EN60529. La cellule de mesure ne peut être seulement
utilisée que pour des substances inflammables pour lesquelles les membranes des
cellules de mesure sont suffisamment résistantes aux influences des produits chimiques et
à la corrosion.
Indication
Les transmetteurs de pression PBMN sont spécifiés, respectivement dimensionnés, de telle
façon qu’ils puissent être utilisés complètement recouverts de poussières.
!
!
!
!
!
!
SEV 11 ATEX 0129
4/4
11092230 / P95.4007 H / 04.05.2018
4.
Mai
.
2018
15:22
Elektrischer Anschluss
Für:
II 1G Ex ia IIC T4/T6 Ga
II 1/2G Ex ia IIC T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Interne Kapazität: Ci = 31 nF
Interne Induktivität: Li = 3 µH
Spannung Ui
30 VDC
Strom Ii
100 mA
Leistung Pi
0.75 W
Electrical connections
For:
II 1G Ex ia IIC T4/T6 Ga
II 1/2G Ex ia IIC T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Internal capacity: Ci = 31 nF
Internal inductivity: Li = 3 µH
Voltage Ui
30 VDC
Current Ii
100 mA
Power Pi
0.75 W
Branchements électriques
Pour:
II 1G Ex ia IIC T4/T6 Ga
II 1/2G Ex ia IIC T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Capacité interne: Ci = 31 nF
Inductance interne: Li = 3 µH
Voltage Ui 30 VDC
Courant Ii 100 mA
Alimentation Pi 0.75 W
Zulässige Temperaturbereiche / Admissible temperature zones / Plages de temrature admissible
Zusammenhang zwischen Temperaturklasse, Umgebungstemperatur (Ta) und höchstzulässiger Medientemperatur (Tp):
Correlation between temperature class, ambient temperature (Ta) and maximum permissible medium temperature (Tp):
Corrélation entre la classe de température, la température (Ta) ambiante et la température du fluide maximum permise (Tp):
Gültig für folgende Drucktransmitter /
Valid for following pressure transmitter /
Valable pour les transmetteurs de pression suivants:
Prozessanschluss / Process connection / Connexion du process:
- Ohne Kühlstrecke / Without cooling neck / Sans d’un refroidisseur
Ausgangsanschluss / Output connection / Raccordements électriques:
- Feldgehäuse / Field housing / Boîtier de terrain
- DIN 43650 Anschluss / DIN 43650 connector / DIN 43650 connecteur
- Rundstecker M12 4polig / M12 4pin connector / M12 4pin connecteur
Für / For / Pour :
II 1G Ex ia IIC T4/T6 Ga
II 1/2G Ex ia IIC T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Für Staub / For dust / Pour poussièr:
Max. Oberflächentemperatur / Max. surface temperature / Max. température surface:
-40°C Ta 70°C, T = 107°C
Gültig für folgende Drucktransmitter /
Valid for following pressure transmitter /
Valable pour les transmetteurs de pression suivants:
Prozessanschluss / Process connection / Connexion du process:
- Mit Kühlstrecke / With cooling neck / Avec d’un refroidisseur
Ausgangsanschluss / Output connection / Raccordements électriques:
- Feldgehäuse / Field housing / Boîtier de terrain
Für / For / Pour :
II 1G Ex ia IIC T3/T4/T6 Ga
II 1/2G Ex ia IIC T3/T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Für Staub / For dust / Pour poussièr:
Max. Oberflächentemperatur / Max. surface temperature / Max. température surface:
-40°C Ta 70°C, T = 107°C
Gültig für folgende Drucktransmitter /
Valid for following pressure transmitter /
Valable pour les transmetteurs de pression suivants:
Prozessanschluss / Process connection / Connexion du process:
- Mit Kühlstrecke / With cooling neck / Avec d’un refroidisseur
Ausgangsanschluss / Output connection / Raccordements électriques:
- DIN 43650 Anschluss / DIN 43650 connector / DIN 43650 connecteur
- Rundstecker M12 4polig / M12 4pin connector / M12 4pin connecteur
Für / For / Pour :
II 1G Ex ia IIC T3/T4/T6 Ga
II 1/2G Ex ia IIC T3/T4/T6 Ga/Gb
II 1D Ex ia IIIC T107°C Da
IP 6x
Für Staub / For dust / Pour poussièr:
Max. Oberflächentemperatur / Max. surface temperature / Max. température surface:
-40°C Ta 70°C, T = 107°C
EU-Konformitätserklärung
EU Declaration of Conformity
Déclaration UE de Conformité
Wir erklären in alleiniger Verantwortung, dass die Produkte, auf die sich diese Erklärung bezieht, die grund-
legenden Anforderungen der angegebenen Richtlinie(n) erfüllen und basierend auf den aufgeführten
Norm(en) bewertet wurden.
We declare under our sole responsibility that the products to which the present declaration relates comply
with the essential requirements of the given directive(s) and have been evaluated on the basis of the listed
standard(s).
Nous déclarons sous notre seule responsabilité que les produits auxquels se réfère la présente déclaration
sont conformes aux exigences essentielles de la directive/ des directives mentionnée(s) et ont été évalués
sur la base de la norme/ des normes listée(s).
x = beliebige Zahl oder Buchstabe / any figure or letter / n’importe quel nombre ou lettre
PELV Anforderungen gemäss EN 60204-1: 0VDC (GND) soll an einem Punkt im System mit Schutzerde verbunden werden.
PELV requirements according to EN 60204-1: 0 VDC (GND) is to be connected at one point in the system with protective earth.
Exigences TBTP selon la norme EN 60204-1: 0 VDC (GND) doit être connecté à un point dans le système avec le conducteur de
protection.
Richtlinie(n) 2014/30/EU, 2014/34/EU, 2011/65/EU
Directive(s) Klicken Sie hier, um Text einzugeben
Directive(s) Klicken Sie hier, um Text einzugeben
Norm(en) EN 80079-34:2013, EN 60079-0:2012+A11:2013, EN 60079-11:2012,
Standard(s) EN 60079-26:2015, EN 61000-6-2:2005, EN 61000-6-3:2007+A1:2011
Norme(s) EN 61326-2-3:2013, EN 50581:2012
Konformitätsbewertungsstelle: Electrosuisse, KNr. 1258
Conformity assessment center Luppmenstrasse 1
Centre d‘évaluation et de mise en conformité CH-8320 Fehraltorf
EU- Baumusterprüfbescheinigung: SEV 11 ATEX 0129
EU type examination certificate
Attestation d'examen UE de type
Ort und Datum Frauenfeld, 04.04.2016 Unterschrift/Name/Funktion Christoph Kluser
Place and date Signature/name/function Head of Product Segment
Lieu et date Signature/nom/fonction Sensor Solutions
Baumer_PxMx_DE-EN-FR_CoC_81164147.docx/su 1/1
Baumer Electric AG
P.O. Box Phone +41 (0)52 728 1122 UBS AG • Clearing 239 • SWIFT/BIC UBSWCHZH80A
Hummelstrasse 17 Fax +41 (0)52 728 1144 (CHF) Konto 239-429 007 02R • IBAN CH64 0023 9239 4290 0702R
CH-8501 Frauenfeld sales.ch@baumer.com (EUR) Konto 239-429 007 62P • IBAN CH11 0023 9239 4290 0762P
MwSt-Nr. 192 892 www.baumer.com (USD) Konto 239-429 007 61G • IBAN CH44 0023 9239 4290 0761G
PBMx xxxxxxA1xxxxxxxx1x
PBMx xxxxxxA1xxxxxxxx1x Sxx
PBMx xxxxxxA1xxxxxxxx1x Cxx
PSMN xxxxxxA1xxxxxxxx1x
PSMN xxxxxxA1xxxxxxxx1x Sxx
PSMN xxxxxxA1xxxxxxxx1x Cxx
PSMN xxxxxxA1x9xxxxxx1x/9001/xxx
PSMN xxxxxxA1x9xxxxxx1x/9001/xxx Sxx
PSMN xxxxxxA1x9xxxxxx1x/9001/xxx Cxx
Hersteller
Manufacturer
Fabricant
Baumer Electric AG
Bezeichnung
Description
Description
Elektronische Druckmesstechnik
Electronic pressure measurement
Electronique mesure de pression
Typ(en) / Type(s) /Type(s)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Baumer PBMN high pressure Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à