2
68-3621-50 Rev. B
04 21
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2021 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
Connecting Power
Power off all devices that will be directly connected to the receiver.
Wire the 24 W power supply (see previous page,
1
) to the
transmitter 2-pole captive screw connector (
3
), and the 6 W
power supply (
2
) to the receiver (see the illustration at right for
wiring instructions).
NOTE: The UCS FT 901 (transmitter) can also be powered
by the Host device, without the need for the external
power supply.
Once a unit receives power, the front panel Power LED (see the
unit illustrations on the right,
A
) lights.
Connecting the Host (Transmitter)
1. Connect a USB Type A-to-C (or Type C-to-C) cable from the
Host device to the transmitter Host port (
4
). The Host LED
on the transmitter (
B
) lights as communication between the
transmitter and host device is established.
NOTE: The transmitter is compatible with USB 3.2
host ports ONLY. USB 3.2 ports are either blue Type
A, Type C, or labeled with a SuperSpeed trident logo
(see below).
®
2. Connect a multimode fiber optic cable from the output port of the transmitter to the input port of the receiver (
5
).
3. Once the cable is connected to both the transmitter and receiver, the front panel Link LEDs light steadily (
C
).
4. Mount the devices, if appropriate.
5. Power on the host device. The transmitter (UCS FT 901) Host LED (
B
) lights when the computer recognizes the transmitter.
Connecting the Devices (Receiver)
Connect up to two USB peripheral devices to the receiver devices ports (
6
). The order of connection does not matter.
The UCS FR 902 (receiver) supplies up to 5 V, 1.5 A to each connected peripheral device.
The system is now ready to operate.
Captive Screw Connector
Tie Wrap
Heat
Shrink
1/8"
(3 mm)
(22 mm)
3/16"
(5 mm) Max.
e
UCS FR 902
LINK
STATUS
POWER
12V
--A MAX
DEVICES INPUT
Tx
1
Rx
2
1.5 A
A C
A C
B
UCS FT 901e
LINK
HOST
STATUS
POWER
12V
0.1A MAX
HOST
USB-C
SS 5G
Tx
OUTPUT
Rx
A B C
A B
C