Real Fyre G45-GL Series Burner Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

1
REV 7 - 1908300925
L-A2-235
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
The Real Fyre gas burner system is to be installed only
in a solid-fuel burning fi replace with a working fl ue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure
of the damper blade. The chimney damper MUST
be fully opened when burning the unit. The unit is
designed to burn with yellow fl ames; thus adequate
ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this gas burner system, you must use
ONLY Peterson Real Fyre parts, decorative media,
and accessories. Use of any other controls, parts,
or accessories not designed for use with Real Fyre
gas burner systems is prohibited. This will void all
warranties, certifi cations, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life. Peterson will not be liable for any
damages caused by this misuse.
*Note: Solid-fuels shall not be burned in a fi replace
where a decorative appliance is installed.
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE UNIT.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use with the type
of gas indicated on the rating plate.
Installation and service must be performed by
a qualifi ed professional service technician,
service agency, or the gas supplier.
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60
CSA 2.26
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
INSTALLATION &
OWNER’S MANUAL
G45-GL VENTED GAS BURNER SYSTEMS
Standard and Stainless
Steel Burner Systems:
G45-GL- ** (P)A
G45-GL- ** -02(M)(P)(-SS)
G45-GL- ** -11(M)(P)(-SS)
G45-GL- ** -15(M)(P)(-SS)
G45-GL- ** -17(M)(P)(-SS)
**Sizes:
(16/19, 18, 24, 30, 36)
Regulated burner system for
use w/ propane or natural gas
2
REV 7 - 1908300925
L-A2-235
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Le Real Fyre système de brûleur doit être installée
seulement dans une cheminée brûlante de combustible
solide avec une conduite de cheminée fonctionnante
et être construit avec du matériel non-combustible.
L'installation, y compris des dispositions pour l'air de
combustion et de ventilation doit se conformer au code
national de gaz de carburant, la norme ANSI Z223.1/
NFPA 54, ou le CSA B149.1, code d'installation de gaz
naturel et de propane, et codes du bâtiment locaux
applicables.
Une bride plus humide est incluse pour maintenir
l’ouverture permanente minimum de passage et pour
empêcher la pleine fermeture de la lame plus humide.
L'amortisseur de cheminée DOIT être entièrement
ouvert en brûlant l'unité. L'unité est conçue pour
brûler avec les fl ammes jaunes; ainsi à ventilation
proportionnée est absolument nécessaire.
Pour être en conformité avec la certifi cation, les listes et
les acceptations du code du bâtiment, ainsi que pour un
fonctionnement en toute sécurité et des performances
correctes, vous devez utiliser UNIQUEMENT les pièces,
les supports de décoration et les accessoires Peterson
Real Fyre. L'utilisation d'autres contrôles, de pièces
ou accessoires non conçu pour une utilisation avec
les systèmes de brûleurs Real Fyre est interdite. Ceci
annulera toutes les garanties, les certifi cations, les
annonces et les approbations du code du bâtiment, et
peut causer des dommages matériels, des blessures
ou des pertes de vie. Peterson ne sera pas responsable
des dommages causés par ce détournement.
*Note: des Plein-carburants ne seront pas brûlés
dans une cheminée où un appareil décoratif
est installé.
POUR L'INSTALLATION DANS
LE COMBUSTIBLE SOLIDE DE
BRÛLANT FIREPLACES*
Ne stockez pas ou n’employez pas l’essence
ou d’autres vapeurs et liquides infl ammables
à proximité de ceci ou d’aucun autre appareil.
CE QUI À FAIRE SI VOUS SENTEZ LE GAZ:
Ouvrez une fenêtre.
N’essayez pas de n’allumer aucun appareil.
Ne touchez aucun commutateur
électrique; n’utilisez aucun téléphone
dans le bâtiment.
Appelez immédiatement le fournisseur
de gaz du téléphone du voisin. Suivez les
instructions du fournisseur de gaz.
Si vous ne pouvez pas atteindre le
fournisseur de gaz, appelez le
département de feu.
AVERTISSEMENT
Si l’information en ce manuel n’est pas suivie
exactement, une incendie ou une explosion
peut résulter, entraînant des dégats
matériels, des blessures, ou la perte de la vie.
Cet appareil sert seulement avec le type de
gaz indiqué de la plaque de contrôle.
Installation et entretien doivent être effectués par
un technicien professionnel qualifi é de service, un
organisme de service ou le fournisseur de gaz.
CONCEPTION CERTIFIÉE
à
Vented Decorative Appliance
ANSI Z21.60
CSA 2.26
INSTALLATEUR :
Laissez ce manuel avec l'appareil.
CONSOMMATEUR:
Maintenez ce manuel pour la future référence.
IMPORTANT: LISEZ CES INSTRUCTIONS
SOIGNEUSEMENT AVANT DE
COMMENCER L'INSTALLATION DE
L'UNITÉ.
Système de brûleur réglementé
l'usage du propane ou du gaz naturel
INSTALLATION ET
MODE D'EMPLOI
G45-GL SYSTÈMES DE BRÛLEURS À GAZ VENTILÉS
Standard et Inoxydable
Systèmes de brûleur d'acier:
G45-GL- ** (P)A
G45-GL- ** -02(M)(P)(-SS)
G45-GL- ** -11(M)(P)(-SS)
G45-GL- ** -15(M)(P)(-SS)
G45-GL- ** -17(M)(P)(-SS)
**Tailles:
(16/19, 18, 24, 30, 36)
3
REV 7 - 1908300925
L-A2-235
TABLE OF CONTENTS
GETTING STARTED
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION .................................................5
FIREPLACE OPERATING SAFETY INFORMATION .............................................................................................7
SPECIFICATIONS..................................................................................................................................................8
DAMPER CLAMP INSTRUCTIONS ....................................................................................................................11
G45-GL BURNER REPLACEMENT PARTS LIST - MANUAL PILOT (A) SERIES ................................................12
G45-GL BURNER REPLACEMENT PARTS LIST - 02 SERIES .............................................................................13
G45-GL BURNER REPLACEMENT PARTS LIST - 11 SERIES .............................................................................14
G45-GL BURNER REPLACEMENT PARTS LIST - 15 SERIES .............................................................................15
G45-GL BURNER REPLACEMENT PARTS LIST - 17 SERIES .............................................................................16
INSTALLATION
INSTALLATION ..................................................................................................................................................17
INSTALL BURNER ..........................................................................................................................................17
HEAT SHIELD PLACEMENT ............................................................................................................................18
LIGHTING TEST .............................................................................................................................................18
SAND/VERMICULITE AND SCREEN PLACEMENT ..............................................................................................19
GLASS / GEMS PLACEMENT............................................................................................................................20
SECONDARY OPTIONS ...................................................................................................................................20
INSTALLING/REPLACING BATTERIES (if applicable) ........................................................................................21
REMOTE TRANSMITTER BATTERY ...................................................................................................................21
RECEIVER/BURNER SYSTEM BATTERIES ..........................................................................................................21
NOTES PAGE ......................................................................................................................................................22
USE, CARE, & SERVICE
LIGHTING INSTRUCTIONS - MANUAL PILOT (A) SERIES ..............................................................................23
FOR YOUR SAFETY, READ BEFORE LIGHTING .................................................................................................23
LIGHTING THE PILOT ....................................................................................................................................23
LIGHTING THE BURNER ................................................................................................................................25
SHUTTING DOWN ..........................................................................................................................................25
PILOT BURNER CHECK/ADJUSTMENT ............................................................................................................25
LIGHTING INSTRUCTIONS - 02 SERIES ............................................................................................................27
FOR YOUR SAFETY, READ BEFORE LIGHTING .................................................................................................27
REMOTE LIGHTING (if equipped) .....................................................................................................................27
MANUAL LIGHTING .......................................................................................................................................29
SHUTTING DOWN ..........................................................................................................................................29
LIGHTING INSTRUCTIONS - SERIES 11 VALVE................................................................................................31
LIGHTING INSTRUCTIONS - SERIES 15 VALVE ...............................................................................................33
LIGHTING INSTRUCTIONS - 17 SERIES ............................................................................................................35
FOR YOUR SAFETY, READ BEFORE LIGHTING .................................................................................................35
LIGHTING THE PILOT ....................................................................................................................................35
REMOTE LIGHTING (if equipped) .....................................................................................................................35
MANUAL LIGHTING .......................................................................................................................................37
SHUTTING DOWN ..........................................................................................................................................39
PILOT BURNER CHECK/ADJUSTMENT ............................................................................................................39
REMOTE OPERATING INSTRUCTIONS - 17 SERIES .........................................................................................39
ORIENTATION ...............................................................................................................................................39
FLAME HEIGHT ............................................................................................................................................39
CLEANING AND SERVICING .............................................................................................................................41
SYNCING THE REMOTE SYSTEM (if applicable) ..................................................................................................42
FLAME DESCRIPTION .......................................................................................................................................42
TROUBLESHOOTING .........................................................................................................................................43
ELECTRONIC PILOT TROUBLESHOOTING (IF APPLICABLE) .........................................................................45
WARRANTY .......................................................................................................................................................46
4
L'INFORMATION DE SÛRETÉ IMPORTANTE DE PRÉINSTALLATION ET DE CHEMINÉE
A. FAITES ATTENTION: Sinon installé, entretenu, et utilisé correctement par ces instructions, ce produit peut causer le
dommage corporel, les dégats matériels, ou les pertes humaines sérieux.
B. AVERTISSEMENT: Quand l'installation dans une cheminée plein-carburant-brûlante, la conduite de cheminée, l'amortisseur,
et le foyer de cheminée doivent ÊTRE COMPLÈTEMENT NETTOYÉS de la suie, de la créosote, des cendres, et de la peinture
lâche, et doivent être inspectés par un décapant qualifié de cheminée. Quelques cheminées plus anciennes peuvent ont besoin
de réparation avant d'installer cet appareil.
C. Cet appareil sert seulement avec le type de gaz indiqué de la plaque de contrôle. Cet appareil n'est pas CONVERTIBLE de
CHAMP pour l'usage avec d'autres gaz.
VÉRIFIEZ LE TYPE de GAZ (normal ou propane) : La fourniture de gaz doit être identique qu'indiquée de votre plaque de
contrôle de système de brûleur. Si la fourniture de gaz est différente, N'INSTALLEZ PAS. Contactez votre revendeur pour l'aide
immédiate.
D. LA PRESSION DE GAZ INSUFFISANTE GARDERA LE PILOTE DU FONCTIONNEMENT CORRECTEMENT (SI ÉQUIPÉ).
N'EMPLOYEZ PAS SI LA PRESSION DE GAZ EST INFÉRIEURE À LA CONDITION MINIMUM.
E. L'admission minimum gaz-fournissent la pression aux fins de l'ajustement d'entrée est 5" ; colonne d'eau (w.c.) sur le gaz naturel
et le 11" ; w.c. sur le gaz de propane. La pression de gaz insuffisante affectera l'opération appropriée du pilote (si équipé).
N'installez pas cet appareil à gaz si la pression minimum n'est pas disponible. L'admission maximum gaz-fournissent la pression
est 10.5" ; w.c. sur le gaz naturel et le 13" ; w.c. sur le gaz de propane. La source de propane doit être réglée. (Ne branchez
pas cet appareil directement à un réservoir de gaz propane non réglementée - cela peut provoquer une explosion.) Ne
branchez pas cet appareil à une bouteille de gaz propane portable.
F. Le système sifflant de gaz doit être classé pour fournir la pression d'admission minimum au débit maximum (BTU/hr).
La perte de pression anormale se produira si la pipe est trop petite, ou la course est trop longue. La pipe de fourniture de gaz
doit être
1
/
2
" ; diamètre intérieur minimum. Si la ligne de gaz est plus longue que 20' ; une ligne de plus grand diamètre peut
être nécessaire. Reportez-vous aux directives NFPA 54 pour plus de détails.
G. Les estimations d'entrée montrées en Btu par heure sont pour des altitudes jusqu'à 2.000 pi. Pour des altitudes au-dessus de
2.000 pi, référez-vous au code national de gaz de carburant ou entrez en contact avec le fabricant avant d'installer ce produit.
H. Cet appareil à gaz et son clapet à gaz principal doivent être disconnected du gaz-fournissent le système sifflant pendant tout
vérificateur de pression de ce système aux pressions d'essai au-dessus de 1/2 psig.
I. Cet appareil à gaz doit être isolé dans gaz-fournissent le système sifflant en fermant le robinet d'isolement d'équipement relié
au gaz-fournissent la ligne pendant tout vérificateur de pression du gaz-fournissent le système sifflant aux pressions d'essai
égales à ou moins d'à 1/2 psig.
J. Pour installer l'appareil à gaz dans votre foyer, le foyer doit satisfaire aux exigences minimales de taille (voir le tableau
des spécifications du produit dans la section SPÉCIFICATIONS).
K. Cet appareil peut être installé dans un marché des accessoires, maison (mobile) de manière permanente située et manufacturée,
où non interdit par des codes locaux. L'installation des appareils a conçu pour la maison manufacturée (États-Unis seulement)
ou installation de caravane résidentielle doit se conformer au CAN/CSA standard Z240 MH, logement mobile, au Canada, ou à
la construction et au standard de sécurité à la maison manufacturés, intitulent 24 CFR, la partie 3280, aux Etats-Unis, ou quand
une telle norme ne s'applique pas, à ANSI/NCSBCS A225.1/NFPA 501A, installations à la maison manufacturées standard.
L. NE PAS installer ce système de brûleur dans un foyer avec une lèvre en cendres ou un renfoncement supérieur à
3
/
4
".
Si ce système de brûleur est installé dans un foyer avec des portes en verre et que les portes ont un cadre qui obstrue le flux
d'air vers le sol du foyer, celui-ci DOIT comporter des fentes (au-dessus du sol du foyer) permettant une ventilation adéquate.
L'ouverture (avec les portes complètement ouvertes) DOIT respecter les exigences minimales de largeur et de hauteur de
la cheminée. Les portes en verre DOIVENT être complètement ouvertes lorsque le brûleur est en marche.Voir la section
SPÉCIFICATIONS pour plus de détails.
M. LE VERRE OU LES GEMMES DE PETERSON (VRAI FYRE) SONT LES SEULS MÉDIAS CERTIFIÉS POUR ÊTRE EMPLO
DANS CE BRÛLEUR. N'EMPLOYEZ AUCUN AUTRE MILIEU. L'installation correcte du verre/gemmes et le placement et
l'installation appropriés du brûleur, sont impérative à l'exploitation sûre de votre appareil. Les problèmes se poseront si tous les
articles ne sont pas correctement installés.
ATTENTION: L'installation et la réparation doivent être faites par un NFI certifié ou tout autre installateur professionnel qualifié.
Installateur: Lisez soigneusement ces instructions avant d'installer ce système de brûleur à gaz. Soyez sûr que vous comprenez
tous les mesures de sécurité et avertissements contenus en ce manuel.
5
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION
A. BE CAREFUL: If not installed, serviced, and used correctly per these instructions, this product can cause serious
personal injury, property damage, or loss of life.
B. WARNING: When installing in a solid-fuel-burning fireplace, the chimney flue, damper, and firebox must be thoroughly
CLEANED of soot, creosote, ashes, and loose paint, and must be inspected by a qualified chimney cleaner. Some older
fireplaces may need repair prior to installing this appliance.
C. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is NOT FIELD CONVERTIBLE
for use with other gasses.
CHECK GAS TYPE (natural or L.P.): The gas supply must be the same as stated on your burner system rating plate. If
gas supply is different, DO NOT INSTALL. Contact your dealer for immediate assistance.
D. INSUFFICIENT GAS PRESSURE WILL KEEP THE PILOT (IF EQUIPPED) FROM OPERATING PROPERLY.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT.
E. The minimum inlet gas-supply pressure for purposes of input adjustment is 5" water column (w.c.) on natural gas and
11" w.c. on L.P. gas. Insufficient gas pressure will affect proper operation of the pilot (if equipped). Do not install this gas
appliance if minimum pressure is not available. The maximum inlet gas-supply pressure is 10.5" w.c. on natural gas and
13" w.c. on L.P. gas. The L.P. source must be regulated. (Do not connect this appliance directly to an unregulated
L.P. gas tank - this can cause an explosion.) Do not connect this appliance to a portable L.P. gas cylinder.
F. The gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).
Undue pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be
1
/
2
" minimum
interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary. Refer to the NFPA 54
guidelines for further details.
G. Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the National
Fuel Gas Code or contact manufacturer before installing this product.
H. This gas appliance and its main gas valve must be disconnected from the gas-supply piping system during any pressure
testing of that system at test pressures in excess of
1
/
2
psig.
I. This gas appliance must be isolated from the gas-supply piping system by closing the equipment shutoff valve connected to
the gas-supply line during any pressure testing of the gas-supply piping system at test pressures equal to or less than
1
/
2
psig.
J. To install the gas appliance in your fireplace, the fireplace MUST meet the minimum size requirements (see
product specifications table in SPECIFICATIONS section).
K. This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited
by local codes. Installation of appliances designed for manufactured home (U.S. only) or mobile home installation must
conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/
NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
L. DO NOT install this burner system in a fireplace with an ash lip or recess greater than
3
/
4
". If this burner system
is installed in a fireplace with glass doors, and the doors have a frame that obstructs airflow to the fireplace floor,
the frame MUST have slots (above the fireplace floor) that allow adequate ventilation. The opening (with doors fully
open) MUST meet the minimum fireplace size front width and height requirements. The glass doors MUST be fully
open when the burner is in operation. See the SPECIFICATIONS section for details.
M. PETERSON (REAL FYRE) GLASS OR GEMS ARE THE ONLY MEDIA CERTIFIED TO BE USED IN THIS BURNER.
DO NOT USE ANY OTHER MEDIA. Correct installation of the glass/gems and proper placement and installation of the
burner assembly, are imperative to safe operation of your appliance. Problems WILL occur if all items are not properly
installed.
CAUTION: Installation and repair must be done by an NFI Certified or other qualified professional installer.
Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand
all safety precautions and warnings contained in this manual.
GETTING STARTED
6
INFORMATIONS SUR LA SÉCURITÉ D'EXPLOITATION DE CHEMINÉE
A. Adultes doivent être présents lors de cet appareil au gaz est en marche. Cette unité ne doit pas être laissé sans surveillance
ou brûlure lorsque tout quelqu'un dort.
B. Gardez le domaine du clair réglé de notation de gaz et libérez des matériaux combustibles, l'essence, et d'autres vapeurs et
liquides inflammables.
C. Ne pas utiliser cet appareil si une partie quelconque a été submergée. Appelez immédiatement un technicien de service qualifié
pour inspecter l'appareil et pour remplacer toute pièce du système de contrôle et toute commande de gaz qui a été sous l'eau.
Tentative d'opération peut entraîner un incendie ou une explosion entraînant des dommages matériels, des blessures ou des
pertes de vie.
D. Una pantalla de la chimenea debe ser en el lugar cuando el sistema está quemando. Las provisiones para el aire de
combustión adecuado deben ser mantenidas. A menos que otras provisiones para el aire de combustión se proporcionen, la
pantalla tendrá una abertura para la introducción de aire de combustión. El aire de combustión es adecuado cuando todas las
llamas se encrespan en la chimenea y lejos de la pantalla. Lorsque vous utilisez un foyer (porte) en verre, les portes en
verre DOIVENT être complètement ouvertes lorsque le brûleur est en marche.
E. Ne retirez pas les plaques signalétiques ou les étiquettes d'avertissement. Ceux-ci sont une composante de sécurité et
d'identification intégrante de cet appareil.
F. Assurez-vous de lire la section de nettoyage et l'entretien et la section de description de la flamme.
7
FIREPLACE OPERATING SAFETY INFORMATION
A. Adults shall be present when this gas appliance is operating. This unit shall not be left burning when unattended or
while anyone is sleeping.
B. Keep the area of the gas burner system clear and free from combustible materials, gasoline, and other flammable
vapors and liquids.
C. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control that has been underwater. Attempted
operation may result in fire or explosion resulting in property damage, personal injury or loss of life.
D. A fireplace screen must be in place when the system is burning. Provisions for adequate combustion air must be
maintained. Unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction
of combustion air. Combustion air is adequate when all flames curl into the fireplace and away from the screen. When a
glass fireplace enclosure (door) is used, the glass doors MUST be fully open when the burner is in operation.
E. Do not remove the rating plates or the warning tags. These are an integral safety and identification component of this
appliance.
F. Be sure to read the CLEANING AND SERVICING and FLAME DESCRIPTION sections.
8
Real Fyre gas burner systems must be installed only in a wood burning fi replace with the minimum
rebox dimensions and venting requirements met (see following tables). This appliance is designed
to burn with yellow fl ames; adequate ventilation is absolutely necessary.
SPECIFICATIONS
Product Specifi cations
Specifi cation Value Qty.
02 burner system battery type D battery 2
Remote transmitter battery type 12V battery 1
Remote receiver battery type AA battery 4
Table 2 - Technical Data (if applicable)
Fireplace Requirements
These requirements MUST be met:
Ash Lip/Recess
DO NOT install this burner system in a fi replace with an
ash lip or recess greater than
3
/
4
". See Fig. 8-1.
Glass Doors
If this burner system is installed in a fi replace with glass
doors, and the doors have a frame that obstructs airfl ow to
the fi replace fl oor, the frame MUST have slots (above the
replace fl oor) that allow adequate ventilation. See Fig. 8-2.
Important: The opening (with doors fully open) MUST
meet the minimum fi replace size front width and
height requirements. See Table 1 and Fig. 8-2.
Important: The glass doors MUST be fully open when the
burner is in operation.
Model
Minimum Fireplace Size BTU Rating
Width *
Depth Height Nat. Gas L.P. Gas
Front Rear
G45-GL-16/19 26" 22" 12" 17" 35k 28k
G45-GL-18 28" 22" 12" 17" 65k 40k
G45-GL-24 34" 28" 12" 17" 75k 50k
G45-GL-30 40" 34" 12" 17" 85k 70k
G45-GL-36 46" 40" 12" 17" 95k 80k
Important Information Regarding Dimensions
* These required widths allow for centering of the unit.
For 02 models, add 2" to both front and rear width.
Rear width is at corresponding depth.
If an ash lip exists, the depth requirement begins inside of the lip (see Fig. 8-1 below).
Table 1 - Product Specifi cations
Fireplace
side view
Max.
3
/
4
"
ASH LIP OR
RECESS UP
TO
3
/4"
(MAX)
DEPTH to be
measured as
shown (when
ash lip exists)
Fig. 8-1 Ash lip/recess detail
Fig. 8-2 Glass doors frame ventilation (if applicable)
Fireplace front view
Slots that
allow
adequate
ventilation
Fireplace fl oor
Frame
(above
replace
oor)
Opening (with
doors fully open)
MUST meet front
width and height
requirements in
Table 1
9
SPECIFICATIONS (cont.)
Only the decorative media options listed below are approved for use with this product. Follow the guidelines to determine
the recommended amount of decorative media needed to cover your burner / fi ll your fi replace fl oor. All decorative media
options are purchased separately; contact your local Real Fyre dealer when ordering.
REQUIRED BASE MEDIA
Sand / vermiculite (included with burner) MUST rst be placed to fi ll the burner pan.
PRIMARY MEDIA OPTIONS
A. Cover Burner Only (minimum requirement)
Glass/gems (purchased separately) MUST be placed to cover the burner (at minimum).
- OR -
B. Fill Entire Fireplace (optional)
Glass/gems (purchased separately) can be placed to fi ll the entire fi replace fl oor. Determine the correct amount needed
(via online calculator or manual formula).
A calculator is available online to determine the correct media amount needed.
Visit realfyre.com/recommended-media/ or simply scan the QR code on the right.
Alternatively use the charts and steps 1-5 below.
SECONDARY MEDIA OPTIONS (optional)
Secondary options such as river stones / geo shapes / glass nuggets / (purchased separately) may also be placed on top
of the glass media.
Determine the volume of area to be fi lled, then subtract a portion of the burner's volume.
Finish by dividing by the glass/gems coverage amount.
Burner size
16/19 18 24 30 36
Amount of 10 lb.
glass bags needed
11112
Burner Volume to be Subtracted (cu. in.)
Burner Size
16/19 18 24 30 36
88 106 130 166 202
Glass/Gems
Coverage Amount
16 cubic inches per lb
1. Determine the square area of the fi replace oor.
2. Multiply amount by 2 (for required 2" cubic height).
3. Subtract portion of burner's volume (see chart).
4. Divide by coverage amount: 16.
5. This is the number of pounds needed.
Example using G45-GL-24 in single-sided trapezoid fi replace:
Volume Formula: (FW + RW) x D x H
2
Front Width: 34" Rear Width: 28" Depth: 12" Height: 2" (set height)
1. (34 + 28) x 12 = 372 sq. in.
2
2. 372 x 2 = 744 cu. in.
3. 744 - 130 (per chart above) = 614 cu. in.
4. 614 / 16 (per chart above) = 38 lbs (rounded)
Important: Relative to the slope of the burner, the height of glass media directly above the burner MUST
NOT exceed 1". The website calculation (or formula below) allows for this requirement.
10
SPECIFICATIONS (cont.)
IN
TH
TP
TH
TP
IN
OUT
Remote receiver
(optional)
Toggle
switch
Wire
harness
Valve
Pilot
assembly
Thermopile
line
Fig. 10-2
11 SERIES WIRING DIAGRAM
S
02 SERIES WIRING DIAGRAM
Fig. 10-1
Valve
Ignition
module
Wire
harness
Battery
box
Ground
wire
Pilot
assembly
Electrode
wires
Manual
switch
OR
Remote
receiver
Thermo switch
15 SERIES WIRING DIAGRAM
Fig. 10-3 Fig. 10-4
17 SERIES WIRING DIAGRAM
Valve
Thermocouple
line
Pilot
assembly
Remote receiver
(optional)
Wire
harness
Valve
Thermocouple
line
Pilot
assembly
Remote
receiver
(optional)
Electrode
wire
Electrode
11
Damper clamp
Set screw
Open
Closed
DAMPER CLAMP INSTRUCTIONS
Fig. 11-1 Damper clamp detail
Fig. 11-2 Damper open / closed
The damper clamp with hex bolt (Fig. 11-1) is provided as a
means to pre
vent full closure of the damper blade. The clamp is
easily attached to most damper blades with pliers or a wrench,
and must be permanently installed. The clamp is designed
to prevent accidental closure of the damper when installed
as illustrated (Fig. 11-2). Should the clamp not fi t, or fail to
provide the permanent vent opening listed in Table 3 below,
have a permanent stop installed, remove the damper blade,
or have the damper cut to provide the minimum permanent
opening required.
Note: The minimum chimney height from hearth to top of chimney is 15'.
Table 3 - Minimum Chimney Damper Vent Opening Requirements
Venting Requirements
THE DAMPER MUST BE COMPLETELY OPENED WHEN OPERATING THIS GAS APPLIANCE TO
ACHIEVE THE BEST VENTILATION POSSIBLE.
THESE ARE MINIMUM DAMPER OPENING SPECIFICATIONS.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fi replaces
Chimney height 16/19" 18" 24" 30" 36"
15' 15 30 36 42 47
20' 13 25 29 35 41
30' 11 19 23 27 31
For masonry-built fi replaces
15' 23 41 46 52 57
20' 21 37 42 47 52
30' 20 34 38 43 47
12
G45-GL BURNER REPLACEMENT PARTS LIST - MANUAL PILOT (A) SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24" burner model shown
10
2
16/19" model 18" model 24" model 30" model 36" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane) SV-19 1 SV-19 1 SV-19 1 SV-19 1 SV-19 1
3.
or
Pressure regulator (natural)
Pressure regulator (propane)
PR-1NAT
PR-2LP
1
1
PR-1NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
4. Valve heat shield HS-43 1 HS-43 1 HS-43 1 HS-43 1 HS-43 1
5. Flame diverter bracket SH-1 1 SH-1 1 SH-1 1 SH-1 1 SH-1 1
6.
Flex connector (w/ adapter),
1/2" O.D. x 12"
CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1
7. Control knob w/ extension EH-11H 1 EH-11H 1 EH-11H 1 EH-11H 1 EH-11H 1
8. Separator screen SC-5 1 SC-6 1 SC-7 1 SC-8 1 SC-9 1
9.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
CS-12
LF-15
1
1
CS-15
LF-15-7
1
2
10. Damper clamp DC-1 1 DC-1 1 DC-1 1 DC-1 1 DC-1 1
3
1
Glass/gems are purchased and packaged separately;
contact your local Real Fyre dealer when ordering.
6
9
DO NOT REMOVE HEAT SHIELD
4
5
7
8
Pilot
Thermocouple
13
G45-GL BURNER REPLACEMENT PARTS LIST - 02 SERIES
24" burner model shown
Pilot
16/19" model 18" model 24" model 30" model 36" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
2.
or
Control valve (natural)
Control valve (propane)
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
3. Control module IMP-1 1 IMP-1 1 IMP-1 1 IMP-1 1 IMP-1 1
4. Main harness assembly WH-03 1 WH-03 1 WH-03 1 WH-03 1 WH-03 1
5.
or
Remote receiver box
(includes remote receiver, battery
box, thermo switch, metal heat
shield, wire harness)
Switch box assembly *
(includes battery box, ON/OFF
switch, thermo switch, metal heat
shield, wire harness)
AR-02-1
EPK-64
1
1
AR-02-1
EPK-64
1
1
AR-02-1
EPK-64
1
1
AR-02-1
EPK-64
1
1
AR-02-1
EPK-64
1
1
6. Remote transmitter (only) † AT-R1-1 1 AT-R1-1 1 AT-R1-1 1 AT-R1-1 1 AT-R1-1 1
7. Valve heat shield HS-38 1 HS-38 1 HS-38 1 HS-38 1 HS-38 1
8. Decorative heat shield HS-37 1 HS-37 1 HS-37 1 HS-37 1 HS-37 1
9. Flame diverter bracket SH-1 1 SH-1 1 SH-1 1 SH-1 1 SH-1 1
10.
Flex connector (w/ adapter),
1/2" O.D. x 12"
CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1
11. Separator screen SC-5 1 SC-6 1 SC-7 1 SC-8 1 SC-9 1
12.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
CS-12
LF-15
1
1
CS-15
LF-15-7
1
2
13.
Damper clamp DC-1 1 DC-1 1 DC-1 1 DC-1 1 DC-1 1
* to add a remote system to an 02M model, use RR-1A
† if equipped
1
DO NOT REMOVE
HEAT SHIELD
9
7
Heat sensor
4
5
8
Electrode
2
3
6
OR
11
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
13
10
Standard model shown here. Burner system
is also available in stainless steel.
Glass/gems are purchased and packaged separately;
contact your local Real Fyre dealer when ordering.
12
System batteries included with burner.
14
G45-GL BURNER REPLACEMENT PARTS LIST - 11 SERIES
3
4
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24" burner model shown
12
2
16/19" model 18" model 24" model 30" model 36" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-3NAT
PAC-3LP
1
1
PAC-3NAT
PAC-3LP
1
1
PAC-3NAT
PAC-3LP
1
1
PAC-3NAT
PAC-3LP
1
1
PAC-3NAT
PAC-3LP
1
1
2.
or
Control valve (natural)
Control valve (propane)
SV-6
SV-6P
1
1
SV-6
SV-6P
1
1
SV-6
SV-6P
1
1
SV-6
SV-6P
1
1
SV-6
SV-6P
1
1
3.
Remote kit * †
(includes receiver, transmitter,
batteries, plastic cover)
RR-1A 1 RR-1A 1 RR-1A 1 RR-1A 1 RR-1A 1
4. Remote transmitter (only) * AT-R1-1 1 AT-R1-1 1 AT-R1-1 1 AT-R1-1 1 AT-R1-1 1
5. Valve heat shield HS-44 1 HS-44 1 HS-44 1 HS-44 1 HS-44 1
6. Decorative heat shield * † HS-36 1 HS-36 1 HS-36 1 HS-36 1 HS-36 1
7. Flame diverter bracket SH-1 1 SH-1 1 SH-1 1 SH-1 1 SH-1 1
8.
Flex connector (w/ adapter),
1/2" O.D. x 12"
CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1
9. Toggle switch SW-2 1 SW-2 1 SW-2 1 SW-2 1 SW-2 1
10. Separator screen SC-5 1 SC-6 1 SC-7 1 SC-8 1 SC-9 1
11.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
CS-12
LF-15
1
1
CS-15
LF-15-7
1
2
12. Damper clamp DC-1 1 DC-1 1 DC-1 1 DC-1 1 DC-1 1
* if equipped
† to add a remote system to an 11M model, use RR-1A and HS-36
5
1
8
Standard model shown here. Burner system
is also available in stainless steel.
DO NOT REMOVE
HEAT SHIELD
7
6
9
11
Glass/gems are purchased and packaged separately;
contact your local Real Fyre dealer when ordering.
10
Pilot
Thermopile
15
G45-GL BURNER REPLACEMENT PARTS LIST - 15 SERIES
5
6
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24" burner model shown
13
3
16/19" model 18" model 24" model 30" model 36" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Electrode CE-15 1 CE-15 1 CE-15 1 CE-15 1 CE-15 1
3.
or
Control valve (natural)
Control valve (propane)
SV-22
SV-23
1
1
SV-22
SV-23
1
1
SV-22
SV-23
1
1
SV-22
SV-23
1
1
SV-22
SV-23
1
1
4.
Pressure regulator (natural)
Pressure regulator (propane)
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
5.
Remote kit * †
(includes receiver, transmitter,
batteries, plastic cover)
VR-1A 1 VR-1A 1 VR-1A 1 VR-1A 1 VR-1A 1
6. Remote transmitter (only) * AT-V1-1 1 AT-V1-1 1 AT-V1-1 1 AT-V1-1 1 AT-V1-1 1
7. Valve heat shield HS-49 1 HS-49 1 HS-49 1 HS-49 1 HS-49 1
8. Decorative heat shield * † HS-36 1 HS-36 1 HS-36 1 HS-36 1 HS-36 1
9. Flame diverter bracket SH-1 1 SH-1 1 SH-1 1 SH-1 1 SH-1 1
10.
Flex connector (w/ adapter),
1/2" O.D. x 12"
CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1
11. Separator screen SC-5 1 SC-6 1 SC-7 1 SC-8 1 SC-9 1
12.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
CS-12
LF-15
1
1
CS-15
LF-15-7
1
2
13.
Damper clamp DC-1 1 DC-1 1 DC-1 1 DC-1 1 DC-1 1
* if equipped
† to add a remote system to a 15M model, use VR-1A and HS-36
4
10
Standard model shown here. Burner system
is also available in stainless steel.
DO NOT REMOVE
HEAT SHIELD
9
8
7
12
Glass/gems are purchased and packaged separately;
contact your local Real Fyre dealer when ordering.
11
Electrode
Thermocouple
Pilot
1
2
16
G45-GL BURNER REPLACEMENT PARTS LIST - 17 SERIES
4
5
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24" burner model shown
14
2
16/19" model 18" model 24" model 30" model 36" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane) SV-37 1 SV-37 1 SV-37 1 SV-37 1 SV-37 1
3.
Pressure regulator (natural)
Pressure regulator (propane)
PR-1NAT
PR-2LP
1
1
PR-1NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
4.
Remote kit * †
(includes receiver, transmitter,
batteries, plastic cover)
VR-1A 1 VR-1A 1 VR-1A 1 VR-1A 1 VR-1A 1
5. Remote transmitter (only) * AT-V1-1 1 AT-V1-1 1 AT-V1-1 1 AT-V1-1 1 AT-V1-1 1
6. Valve heat shield HS-35 1 HS-35 1 HS-35 1 HS-35 1 HS-35 1
7. Decorative heat shield * † HS-36 1 HS-36 1 HS-36 1 HS-36 1 HS-36 1
8. Remote receiver wire harness *
WH-01 1 WH-01 1 WH-01 1 WH-01 1 WH-01 1
9. Flame diverter bracket SH-1 1 SH-1 1 SH-1 1 SH-1 1 SH-1 1
10.
Flex connector (w/ adapter),
1/2" O.D. x 12"
CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1 CK-5-SP 1
11. Control knob w/ extension EH-11H 1 EH-11H 1 EH-11H 1 EH-11H 1 EH-11H 1
12. Separator screen SC-5 1 SC-6 1 SC-7 1 SC-8 1 SC-9 1
13.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
CS-12
LF-15
1
1
CS-15
LF-15-7
1
2
14. Damper clamp DC-1 1 DC-1 1 DC-1 1 DC-1 1 DC-1 1
* if equipped
† to add a remote system to a 17M model, use VR-1A, HS-36, and WH-01
3
10
Standard model shown here. Burner system
is also available in stainless steel.
DO NOT REMOVE
HEAT SHIELD
9
7
6
13
11
Glass/gems are purchased and packaged separately;
contact your local Real Fyre dealer when ordering.
12
1
Pilot
Thermocouple
8
17
When a stainless steel burner system is installed outdoors,
ensure it is not directly exposed to the elements (precipitation,
rain, wind, etc.).
REFER TO THE PARTS LIST WHEN FOLLOWING INSTALLATION
INSTRUCTIONS. 24" standard burner model shown here. Stainless
steel models install the same.
INSTALL BURNER
1. MAKE SURE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove
the cap, if attached (reference Fig. 17-1).
CAUTION: When removing the cap, make sure the stub does not
turn, loosening the connection inside the wall.
3. Attach the nut end of the fl ex connector to the adapter found
on the valve or, if attached, on the regulator behind the valve.
Tighten securely.
4. Place the burner system in the fi replace. Center the burner
from left to right in the fi replace. See Fig. 17-2.
5. Be sure gas to the fi replace is off. Remove the adapter
connected to the fl ex connector. Attach the adapter to the gas-
supply stub using a pipe compound resistant to all gasses.
Tighten securely. Then attach the open end of the fl ex connector
to the adapter. Tighten securely (see Fig. 17-1). Ensure the pan
rests level on the fi replace oor after connection. Adjust the pan
if necessary.
6. LEAK TEST: Turn on the fi replace gas supply, and test at
all connections for leaks using the appropriate soapy water
solution. If bubbles appear, a leak is present. Turn off the
gas and tighten at all connections. Repeat until no leaks are
present. If a leak persists, turn off the gas supply and contact
the local gas company or dealer. NEVER USE A FLAME TO
CHECK FOR LEAKS.
For manual models, continue to HEAT SHIELD section.
7. At this stage the burner system and remote batteries are
to be installed (if applicable). Reference the INSTALLING/
REPLACING BATTERIES section for details.
8. Remote Receiver/Switch Box (02 models only)
It is recommended the receiver/switch box be placed outside
of the fi rebox and a minimum of 6" from the burner/fl ame. See
Fig. 17-1, A.
Alternatively, the box can be placed inside of the fi rebox, but
must be oriented as shown in Fig. 17-1, B. Set the box on its
side and place the bottom of the box toward the right fi rebox
wall (box must be a minimum of 6" from the burner/fl ame). DO
NOT place at the rear of the fi rebox.
Ensure that the box wires remain away from the burner,
valve, heat shield, and fl ame at all times. Coil any excess
wire within the box.
CAUTION: THE BOX WILL BE HOT DURING AND AFTER
OPERATION.
The Real Fyre burner system must be installed by a qualifi ed professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefi t from the burner system. Check to be
sure the burner system is designed and labeled for the type of gas (natural or propane gas) supplied to
replace. Fireplace fl oor must be level, clean, and smooth (see FIREPLACE SAFETY INFORMATION section).
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
INSTALLATION
Fig. 17-2 Center burner in fi replace
Fig. 17-1 Connect gas supply
Flex
connector
Adapter
Gas
supply
stub
(11 model
shown)
Fig. 17-3 Box placement (if applicable)
RECOMMENDED BOX PLACEMENT:
OUTSIDE OF FIREBOX
ALTERNATIVE BOX PLACEMENT:
INSIDE OF FIREBOX (PLACE ONLY AS SHOWN)
Valve wire
bundle
Box
Burner pan
6"
min
(FIREBOX)
02 models
only
A
Bottom
6"
min
B
BOX ON ITS SIDE
18
INSTALLATION (cont.)
9. Remote Receiver Install (11, 15, & 17 models only)
If this unit was shipped with a remote, read and follow
the separate remote instructions (packed with remote) for
complete remote installation. Reference Fig. 18-1.
10. Decorative Heat Shield (if applicable)
11, 15, & 17 Models: Ensure the remote receiver is
properly installed (with the plastic cover over it). Then
place the decorative heat shield over the remote receiver.
See Fig. 18-1.
02 Models: Place the decorative heat shield over the
remote receiver / switch box (see Fig. 18-1).
CAUTION: THE REMOTE RECEIVER / SWITCH BOX AND
DECORATIVE HEAT SHIELD WILL BE HOT
DURING AND AFTER OPERATION.
HEAT SHIELD PLACEMENT
TO PREVENT DAMAGE AND FAILURE:
IT IS CRITICAL THAT THE HEAT SHIELD BE
PLACED CORRECTLY OVER THE VALVE PRIOR TO
OPERATION.
TO PREVENT OVERHEATING:
Place the heat shield over the valve as shown in the applicable
image of Fig. 18-2. It should rest fl at above the valve.
Keep the area directly above and below the heat shield
clear of decorative media or any other objects at all times.
Important: Ensure any lines/tubes/wires from the valve
do not interfere with heat shield placement.
LIGHTING TEST
Prior to proceeding with installation, perform a lighting test
(see lighting instructions for lighting your burner). Allow the
unit to completely cool after testing.
IMPORTANT
For all valves, the air MUST be purged from the gas line
before the pilot will light and burn properly. The time needed
to purge will depend on the length of the gas line to the
unit and the amount of time since the unit or gas line was
last used. It may take several minutes before all the air is
purged and the pilot will light and burn properly. Reference
the LIGHTING INSTRUCTIONS section in this manual.
Installation continued on next page
Fig. 18-2 Place heat shield
Heat shield MUST:
be placed over valve
• rest at
be kept clear of all media and objects
Manual Model 02 Model
11 Model 15 Model
17 Model
Fig. 18-1 Install remote receiver and
heat shield (as applicable)
Remote installation will vary by model, refer
to separate remote instructions (if applicable)
11, 15, 17 models:
place remote on right side
(11 model shown)
Receiver (w/ plastic cover
and heat shield)
02 models: place box on right side
Box (w/ heat shield)
19
SAND/VERMICULITE AND SCREEN PLACEMENT
The sand/vermiculite supplied with the unit is specially selected
for use with either natural or propane gas. It maximizes fl ame
distribution and provides a cleaner burning fl ame.
CAUTION: Use only sand for natural gas burners and
vermiculite for propane gas burners.
1. Partially fi ll the burner pan with the sand/vermiculite until
it rests at a level toward the top of the burner tubes as
shown in Fig. 19-1.
Pack the sand/vermiculite down around the tubes.
Slope the sand/vermiculite in the front portion of the
pan (see Fig. 19-3).
Leave space within the pan to allow for screen and
glass placement.
• Avoid spilling the sand/vermiculite on the pilot
assembly. DO NOT place sand/vermiculite on any
other parts of the burner, valve, or heat shield.
Store excess sand/vermiculite in a safe location.
2. Place the separator screen over the sand/vermiculite and
pan. The rear of the screen must hook over the rear of
the burner pan as shown in Fig. 19-2 and Fig. 19-3. If the
front of the screen rises up from the fl oor of the pan, bend
it downward as needed.
Note: The screen must correctly rest onto the burner pan. If
it sits too high, remove some of the sand/vermiculite
to ensure a proper fi t. DO NOT allow for any sand/
vermiculite to be above the screen.
INSTALLATION (cont.)
Installation continued on next page
Fig. 19-1 Place sand/vermiculite
(17 model shown)
Fig. 19-2 Place screen
(Pack sand/vermiculite
around tubes)
Burner pan
Sand/vermiculite up to
burner tubes
Separator screen
(If front of screen rises up and does not
rest fl at, bend it downward as needed)
Separator
screen
Burner tubes
Burner pan
Sand/vermiculite level
Sand/
vermiculite
sloped
Fig. 19-3 Sand/vermiculite & screen detail
Side view
Partially fi ll pan (only) with
sand/vermiculite & slope
front portion of pan.
20
INSTALLATION (cont.)
KEEP SAND/VERMICULITE, GLASS/GEMS, AND ALL
FOREIGN OBJECTS AWAY FROM THE PILOT ASSEMBLY,
VALVE ASSEMBLY, AND HEAT SHIELD DURING MEDIA
PLACEMENT AND AT ALL TIMES. SEE FIG. 20-3.
GLASS / GEMS PLACEMENT
CAUTION: Glass pieces may have sharp edges. Be careful
handling the glass. Use hand protection, such as
gloves, if necessary.
Glass/gems MUST be placed to cover the burner (at minimum)
for the system to operate properly. Alternatively, glass/gems can
be placed to fi ll the entire fi replace oor. The glass media is
purchased and packaged separately. Contact your local Real
Fyre dealer for ordering information.
Reference the SPECIFICATIONS section for details on the
recommended amounts of media.
1. After the required sand/vermiculite and screen have
been placed, pour the glass media (glass, gems) so that the
burner pan is covered completely and evenly (see Fig. 20-1).
Relative to the slope of the burner, DO NOT exceed a
1" depth of glass (directly above the burner pan) as
shown in Fig. 20-2. Any additional glass/gems above
the burner may cause unsafe operation.
DO NOT place any glass media directly on the pilot
assembly, on or within the heatshield, or under a
knob if one exists at the front of the valve (see Fig.
20-1 and Fig. 20-3).
Store excess glass media in a safe location.
At this stage the burner will function as designed. However, more
glass media may be added around the burner for decorative
purposes:
2. Complete placement by pouring the remaining glass media
on the fl oor of the fi replace, around the front, rear, and sides
of the burner system (see Fig. 20-1).
If applicable, the glass media may be placed around the
remote receiver / switch box. Leave the front of the remote
receiver / switch box clear for control access.
CAUTION: BURN HAZARD. GLASS AND/OR GEMS ON BURNER SYSTEM WILL REMAIN HOT
FOR SOME TIME AFTER USE. You must maintain the placement as shown to ensure proper
operation of the burner system. If you need to reposition any media to maintain the proper
layout, use heat-resistant gloves or allow media adequate time to cool before handling.
SECONDARY OPTIONS
After the required sand/vermiculite, screen, and glass/gems
have been placed, various river stone, geo shape, and glass
nugget options are available. If one of these secondary options
are purchased, place them as desired in a decorative pattern
on top of the primary media.
Note: These options are not designed to be placed directly on
the burner.
Keep area clear (see below)
Fig. 20-3 Keep pilot, valve, & shield clear
KEEP CLEAR
OF ALL MEDIA
Fig. 20-1 Glass media placement
Burner pan
1"
Relative to the slope of the
burner, DO NOT exceed a
1" depth of glass (directly
above the burner pan)
Fig. 20-2 Proper media placement
Cover burner (at minimum)
- OR -
Fill entire fi replace (optional)
Keep pilot clear
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Real Fyre G45-GL Series Burner Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues