GRUNDFOS INSTRUCTIONS
Unilift AP12, AP35, AP50
Installation and operating instructions
2
3
Table of contents
Unilift AP12, AP35, AP50
English (US)
Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Français (CA)
Notice d'installation et de fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Español (MX)
Instrucciones de instalación y operación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Appendix 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
4
English (US)
English (US) Installation and operating instructions
Original installation and operating
instructions
These installation and operating instructions
describe Grundfos Unilift AP12, AP35 and
AP50.
Sections 1-5 give the information necessary to
be able to unpack, install and start up the
product in a safe way.
Sections 6-10 give important information about
the product, as well as information on service,
fault finding and disposal of the product.
CONTENTS
Page
1. Limited warranty
5
2. General information
5
2.1 Symbols used in this document
5
2.2 Overview drawing
6
3. Receiving the product
6
3.1 Inspecting the product
6
3.2 Scope of delivery
6
4. Installing the product
6
4.1 Pipe connection
7
4.2 Minimum space
7
4.3 Location
7
4.4 Adjustment of cable length for float
switch
8
4.5 Electrical connection
8
5. Starting up the product
9
5.1 Starting
9
6. Product introduction
10
6.1 Applications
10
6.2 Identification
12
6.3 Functions
12
6.4 Pump construction
12
7. Servicing the product
13
7.1 Cleaning the pump
14
7.2 Contaminated pumps
14
7.3 Replacement of parts
14
8. Fault finding the product
15
9. Technical data
16
9.1 Operating conditions
16
9.2 Sound pressure level
16
9.3 Storage
16
10. Disposing of the product
16
Prior to installation, read this
document. Installation and operation
must comply with local regulations
and accepted codes of good practice.
Successful operation depends on
careful attention to the procedures
described in this manual. Keep this
manual for future use.
5
English (US)
1. Limited warranty
Products manufactured by Grundfos Pumps
Corporation (Grundfos) are warranted to the
original user only to be free of defects in
material and workmanship for a period of 24
months from date of installation, but not more
than 30 months from date of manufacture.
Grundfos' liability under this warranty shall be
limited to repairing or replacing at Grundfos'
option, without charge, F.O.B. Grundfos' factory
or authorized service station, any product of
Grundfos manufacture. Grundfos will not be
liable for any costs of removal, installation,
transportation, or any other charges that may
arise in connection with a warranty claim.
Products which are sold, but not manufactured
by Grundfos, are subject to the warranty
provided by the manufacturer of said products
and not by Grundfos' warranty.
Grundfos will not be liable for damage or wear to
products caused by abnormal operating
conditions, accident, abuse, misuse,
unauthorized alteration or repair, or if the
product was not installed in accordance with
Grundfos' printed installation and operating
instructions and accepted codes of good
practice. The warranty does not cover normal
wear and tear.
To obtain service under this warranty, the
defective product must be returned to the
distributor or dealer of Grundfos' products from
which it was purchased together with proof of
purchase and installation date, failure date and
supporting installation data. Unless otherwise
provided, the distributor or dealer will contact
Grundfos or an authorized service station for
instructions. Any defective product to be
returned to Grundfos or a service station must
be sent freight prepaid; documentation
supporting the warranty claim and/or a Return
Material Authorization must be included if so
instructed.
Grundfos will not be liable for any incidental or
consequential damages, losses, or expenses
arising from installation, use, or any other
causes. There are no express or implied
warranties, including merchantability or fitness
for a particular purpose, which extend beyond
those warranties described or referred to above.
Some jurisdictions do not allow the exclusion or
limitation of incidental or consequential
damages and some jurisdictions do not allow
limitations on how long implied warranties may
last. Therefore the above limitations or
exclusions may not apply to you. This warranty
gives you specific legal rights and you may also
have other rights which vary from jurisdiction to
jurisdiction.
Products which are repaired or replaced by
Grundfos or authorized service center under the
provisions of these limited warranty terms will
continue to be covered by Grundfos warranty
only through the remainder of the original
warranty period set forth by the original
purchase date.
2. General information
2.1 Symbols used in this document
2.1.1 Warnings against hazards involving
risk of death or personal injury
The text accompanying the three hazard
symbols DANGER, WARNING and CAUTION
will be structured in the following way:
2.1.2 Other important notes
DANGER
Indicates a hazardous situation
which, if not avoided, will result in
death or serious personal injury.
WARNING
Indicates a hazardous situation
which, if not avoided, could result in
death or serious personal injury.
CAUTION
Indicates a hazardous situation
which, if not avoided, could result in
minor or moderate personal injury.
SIGNAL WORD
Description of hazard
Consequence of ignoring the warning.
- Action to avoid the hazard.
A blue or grey circle with a white
graphical symbol indicates that an
action must be taken.
A red or grey circle with a diagonal
bar, possibly with a black graphical
symbol, indicates that an action must
not be taken or must be stopped.
If these instructions are not observed,
it may result in malfunction or damage
to the equipment.
Tips and advice that make the work
easier.
6
English (US)
2.2 Overview drawing
Fig. 1 Unilift AP pump
3. Receiving the product
3.1 Inspecting the product
Check that the product received is in
accordance with the order.
Check that the voltage and frequency of the
product match voltage and frequency of the
installation site.
3.2 Scope of delivery
The box contains the following items:
pump
power cable
float switch (if included with this model)
installation and operating instructions.
4. Installing the product
TM03 6189 4406
CAUTION
Crushing of feet
Minor or moderate personal injury
- Wear safety shoes when handling
the product.
- Use the pump handle to move the
pump. Do not lift it by the power
cable.
Outlet port
Pump
sleeve
Inlet strainer
Handle with
clamp
Float
switch
DANGER
Electric shock
Death or serious personal injury
- The installation, electrical
connection, and maintenance of
the product must be carried out by
an authorized electrician in
accordance with the National
Electrical Code and any state, local
governing codes and regulations.
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product.
- Make sure that the power supply
cannot be accidentally switched
on.
DANGER
Electric shock
Death or serious personal injury
- Pump installation in a sump pit,
basin or tank must be carried out
by qualified, specially trained
persons in accordance with the
National Electrical Code and any
state, local governing codes and
regulations.
WARNING
Moving parts
Minor or moderate personal injury
- Make sure that persons cannot
come into contact with moving
parts.
Do not lift the pump by the power
cable or by the outlet pipe or hose.
If the pump is installed in a well or
tank, lower and lift it by means of a
wire or chain fastened to the pump
handle.
7
English (US)
4.1 Pipe connection
Threaded steel or rigid plastic pipes can be
screwed directly into the 1.5" NPT outlet port.
For permanent installation, we recommend that
you fit a union, a non-return valve and an
isolating valve in the outlet pipe.
Other recommendations:
For portable or temporary installations, a
plastic outlet pipe can be used in conjunction
with a suitable, screwed connection or a
hose coupling.
Threads must be sealed using Teflon
®
tape.
4.2 Minimum space
When the pump is installed in a permanent
installation with a float switch, and the cable
length is set to the minimum length of at least
4 in. (100 mm), the minimum dimensions of the
sump pit, basin or tank must be as shown in
fig. 2.
In addition, the sump pit, basin or tank must be
sized according to the relation between the
water flow to the sump pit, basin or tank and the
pump performance.
Fig. 2 Minimum installation dimensions
4.3 Location
The pump can be used in vertical as well as
horizontal position with the outlet port as the
highest point of the pump. See fig. 3.
During operation, the inlet strainer must always
be completely covered by the pumped liquid.
Fig. 3 Pump positions
When the pipe or hose has been connected,
place the pump in its operating position.
Position the pump so that the inlet strainer will
not be blocked by sludge, mud or similar
materials.
In a permanent installation, the installation site
must be cleared of sludge, pebbles, etc. before
the pump is installed.
We recommend that you place the pump on a
solid base. See fig. 4.
Fig. 4 Pump placed on a plate
DANGER
Electric shock
Death or serious personal injury
- Route the power cable in a way
that supports it and protects it from
being cut, pinched or damaged.
- If the power cable is cut, pinched,
or damaged, replace it before
using the product.
DANGER
Electric shock
Death or serious personal injury
- Do not remove the power cable
and strain relief.
- Do not connect electrical conduit to
the pump.
Use an approved level controller with
a current rating that matches the
service factor marked on the
product's nameplate.
Do not install the pump hanging from
the outlet pipe or hose.
Do not lift the pump by its power
cable. Lower and lift it by means of a
wire or chain fastened to the pump
handle.
TM03 6194 4406
TM03 6193 4406
TM03 3691 4406
‹‹
‹‹
550 mm
600 mm
21.5 in. (550 mm)
23.5 in.
(600 mm)
••
••
••
8
English (US)
4.4 Adjustment of cable length for float
switch
The difference in level between start and stop
can be adjusted by changing the free cable
length between the float switch and the pump
handle.
An increased free cable length will result in
fewer starts and stops and a large difference
in level.
A reduced free cable length will result in
more frequent starts and stops and a small
difference in level.
The free cable length must be a minimum of 4
in. (100 mm) and a maximum of 14 in. (355 mm).
The stop level must be above the inlet strainer to
prevent the pump from taking in air.
Fig. 5 Start and stop levels
The start and stop levels vary according to the
cable length.
Manual operation can be achieved in one of two
ways:
Unplug both the pump and the float switch
from the wall socket. Insert the pump plug
into the wall socket.
Keep the float switch in a high position by
attaching it to the outlet pipe/hose.
4.5 Electrical connection
The electrical connection must be carried out in
accordance with local regulations and follow the
National Electrical Code (USA) and the
Canadian Electrical Code. The pump must be
grounded. The operating voltage and frequency
are marked on the nameplate. Make sure that
the motor is suitable for the power supply on
which it will be used.
TM03 6192 4406
Unilift AP start and stop levels
Cable length min.
4 in. (100 mm)
Cable length max.
14 in. (355 mm)
Start Stop Start Stop
19.7 in.
(500 mm)
11.8 in.
(300 mm)
21.7 in.
(550 mm)
4 in.
(100 mm)
Minimum/maximum
cable length
Start
Stop
DANGER
Electric shock
Death or serious personal injury
- Pump installation in a sump pit,
basin or tank must be carried out
by qualified, specially trained
persons in accordance with the
National Electrical Code and any
state, local governing codes and
regulations.
WARNING
Electric shock
Death or serious personal injury
- Connect the product only to a
properly grounded receptacle.
- We recommend that you connect
the pump to an electrical circuit
with a Ground Fault Circuit
Interrupter (GFCI).
WARNING
Electric shock
Death or serious personal injury
- The protective ground of the pump
power plug must be connected to
the protective ground receptacle of
the power outlet.
- The plug must have the same
ground connection system as that
of the power outlet. If not, use a
suitable adapter.
9
English (US)
Power supply
1 x 115 V, 60 Hz
1 x 230 V, 60 Hz.
To connect the pump for manual operation,
insert the pump plug into a wall socket. If a float
switch is included for automatic operation, it will
be of the "piggy-back" design. Insert the float-
switch plug into the wall socket, and insert the
pump plug into the back of the float-switch plug.
Fig. 6 Pump and float-switch plugs
Fig. 7 Wiring diagram
Motor protection
The Unilift AP pumps have built-in thermal
overload protection and require no additional
motor protection. If the motor is overloaded, it
will stop automatically. When cooled to normal
temperature, the motor will start automatically.
5. Starting up the product
5.1 Starting
Before starting the pump, check that the
following requirements are fulfilled:
The pump's inlet strainer must be
submerged below the surface of the liquid.
The pump is placed on a base so that the
inlet strainer is not blocked by silt, mud or
similar materials.
The pipe or hose connection is tight.
The outlet pipe or hose is open (hose not
bent, etc.).
The pump is connected to the power supply
in accordance with the instructions.
For pumps with a float switch, check that the
float switch can move freely. See section
4.4 Adjustment of cable length for float
switch.
Startup procedure:
1. Switch on the pump and check:
– that the pump is operating properly
– that water is being pumped.
2. For pumps with a float switch, check that the
float switch will allow the pump to pump
down to the chosen level according to fig. 5.
If you want to pump below this level, hold the
float switch in vertical position.
TM03 4461 2106
TM06 9144 1717
Float-switch plug
("piggy-back")
Wall socket
Pump plug
Power supply cable leads
Motor connections
Brown Black
Yellow/green
Green
Blue White
DANGER
- Minor to moderate personal injury
- Do not touch the inside of the
pump while the pump is running.
10
English (US)
6. Product introduction
The Grundfos Unilift AP pump is a single-stage,
submersible pump designed for the pumping of
wastewater.
The pump is designed for automatic operation
with a float switch or for manual operation.
The pump can be installed in a permanent
installation or used as a portable pump.
6.1 Applications
Incorrect use of the pump, for example resulting
in blockage or wear of the pump will void the
pump's warranty. Note that the pump is not
suitable for these liquids:
sewage
liquids containing long fibers
flammable liquids (oil, gasoline, etc.)
aggressive liquids.
liquids containing solids exceeding the
pump's recommended maximum particle
size.
The pump is capable of pumping water
containing a limited quantity of spherical
particles, see section Maximum particle size on
page 16.
Pumping of spherical particles exceeding the
maximum particle size for the pump may block
or damage the pump.
DANGER
Electric shock
Death or serious personal injury
- Do not use the pump in or at
swimming pools, garden ponds,
etc. when there are persons in the
water.
If the pump has been used for very
dirty or chlorinated water, flush the
pump thoroughly with clean water
after use.
Wear gloves and other suitable
personal protective equipment in
accordance with local regulations.
Observe local regulations on any
exposure to wastewater.
11
English (US)
* Check the regional or local EX-approval requirements for surface water at gas station and in
parking areas.
Note: Unilift AP does not have any explosion proof approval. See Grundfos SL range.
Applications AP12 AP35 AP50
Pumping of gray wastewater with impurities up to the sizes listed
in the section Maximum particle size on page 16, and according to
the liquid temperature, viscosity and pH value the pump is
designed for.
●●●
Mobile use to dewater ponds, pools, flooded basements and other
similar applications.
●●●
Stationary installation in collecting tanks, sump wells and pits to
dewater domestic wastewater (gray wastewater) from showers,
washing machines, sinks, bath tubs etc. excluding wastewater
(black) from toilets.
●●●
Stationary installation in collecting tanks, sump wells and pits to
discharge groundwater, rainwater or surface water.*
●●●
Wastewater from domestic washing machines or commercial and
industrial washing machines, laundries up to the temperature
approved.
●●●
12
English (US)
6.2 Identification
6.2.1 Nameplate
Fig. 8 Nameplate
6.2.2 Type key
6.3 Functions
Pump with float switch
Automatic start and stop.
Pump without float switch
Manual external start and stop.
6.4 Pump construction
The main components of the pump appear from
the table below and figures A, B and C in the
Appendix. See page 43.
The position numbers are referred to in the
cleaning instructions in section 7.1 Cleaning the
pump on page 14.
TM06 9617 2517
Pos. Nameplate text Description
1 Prod. No. Product number
2 Imax Maximum current [A]
3 n Speed [min
-1
]
4 P1 Power input [Hp]
5Qmax
Maximum flow
[gal/min.]
6 Hmax Maximum head [ft]
7Tmax
Maximum liquid
temperature [°F]
8 P.c.:
Production code
(YYWW)
Example Unilift AP 35 B. 50. 08. A 1 V
Type range
Maximum
solids size [mm]
Pump type
Blank = AP Pump
B = AP Basic
Nominal diameter of outlet port
Power output P
2
/ 100 [W]
Level control
A=
Automatic operation
(with float switch)
Blank =
Manual operation
(without float switch)
Motor
1 = Single-phase
3 = Three-phase
Impeller
V = Vortex impeller
Type: UNILIFT AP XX.XX.XX.XX
Prod. No: XXXXXXXX
U: 1x115V~60Hz
Imax: 8,00 A n: XXXX min
-1
P1: X,XX hp XX,X lb
Qmax: XX gal/min Hmax: XX ft
P.c: XXXX
MADE IN HUNGARY
Pos. Description
6 Pump housing
37a O-ring
49 Impeller
55 Pump sleeve with motor
66 Washer
67 Lock nut
84 Inlet strainer
105 Shaft seal
182 Float switch
188a Screws
193 Screws
13
English (US)
7. Servicing the product
Clean the pump before service. See section
7.1 Cleaning the pump.
Check the function of the pump, inspect it for
damage and replace the oil once a year. If the
pump is used for pumping liquids containing
abrasive particles or it is operating continuously,
replace the oil at shorter intervals. See the table
below.
In the case of long operating time or continuous
operation, replace the oil as follows:
The pump contains approximately 60 ml non-
poisonous oil.
Used oil must be disposed of in accordance with
local regulations.
If the drained oil contains water or other
impurities, the shaft seal must be replaced.
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product.
Make sure that the power supply
cannot be accidentally switched
on.
CAUTION
Biological hazard
Minor or moderate personal injury
- Before carrying out maintenance
and service, flush the pump
thoroughly with clean water.
- After dismantling the pump, rinse
the pump parts in clean water.
CAUTION
Sharp element
Minor or moderate personal injury
- Wear protective gloves.
This work must be carried out by
specially trained persons.
Furthermore, all rules and regulations
covering safety, health and
environment must be observed.
Liquid
temperature
[°F (°C)]
The oil must be
replaced after
68 (20) 4500 operating hours
104 (40) 3000 operating hours
131 (55) 1500 operating hours
14
English (US)
7.1 Cleaning the pump
If the pump does not deliver a sufficient quantity
of water because of sediment, dismantle and
clean the pump.
To dismantle the pump, follow this procedure:
1. Disconnect the power supply.
2. Lift the pump out of the liquid and allow it to
drain.
3. Carefully loosen the inlet strainer (84) by
inserting a screwdriver through one of the
holes of the strainer and press it downward.
Repeat the procedure until the strainer is
free and can be removed.
4. Remove the inlet strainer, clean, and refit it.
5. Place the pump on its base in the liquid.
6. Connect the power supply and start the
pump.
If the pump still does not deliver sufficient water,
dismantle the pump:
1. Disconnect the power supply.
2. Lift the pump out of the liquid and allow it to
drain.
3. Carefully loosen the inlet strainer (84) by
inserting a screwdriver through one of the
holes of the strainer and press it downward.
Repeat the procedure until the strainer is
free and can be removed.
4. Remove the inlet strainer and clean it.
5. Unscrew the six screws (188a) close to the
edge of the pump sleeve (55) and lift the
pump housing (6) out of the pump sleeve.
6. Clean the pump housing, the pump, and the
impeller (49).
7. Check to make sure the impeller can rotate
freely. If not, remove the impeller:
– Hold the impeller in place with a
screwdriver while loosening and removing
the lock nut (67) on the shaft.
– Clean the impeller and the shaft.
8. Check the impeller and the shaft. If the
impeller is worn or defective, replace it.
9. Assemble the pump in the reverse order of
dismantling:
– Fit the impeller (49) with the washer and
lock nut (67). Make sure the impeller
engages with the shaft.
– Position the O-ring (37a) in the pump
sleeve and lower the pump onto the pump
housing.
– Fit the six screws (188a) in the pump
housing (6) and tighten securely.
7.2 Contaminated pumps
Any application for service (no matter to whom it
may be made) must include details about the
pumped liquid.
The product will be classified as contaminated if
it has been used for a liquid which is injurious to
health or toxic.
If you request Grundfos to service the product,
contact Grundfos with details about the pumped
liquid before returning the product for service.
Otherwise Grundfos can refuse to accept the
product for service.
Any application for service must include details
about the pumped liquid.
Clean the product in the best possible way
before you return it.
Costs of returning the product are to be paid by
the customer.
7.3 Replacement of parts
The impeller assembly and power cable can be
replaced. The part numbers and the
components included in the service kits can be
found on Grundfos Product Center
(www.grundfos.us). Alternatively, contact your
local Grundfos dealer or service center.
CAUTION
Biological hazard
Minor or moderate personal injury
- Flush the pump thoroughly with
clean water and rinse the pump
parts in water after dismantling.
15
English (US)
8. Fault finding the product
DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product.
Make sure that the power supply
cannot be accidentally switched
on.
Fault Cause Remedy
1. The motor does
not start.
a) No power supply. Connect the power supply.
b) The motor is switched off by the
float switch.
Adjust or replace the float switch.
c) The fuses are blown. Replace the fuses.
d) The motor protection or thermal
relay has tripped.
Wait until the motor protection
trips in again or reset the relay.
e) The impeller is blocked by
impurities.
Clean the impeller.
See section 7.1 Cleaning the
pump.
f) There is a short circuit in the cable
or motor.
Replace the defective part.
2. The motor
protection or the
thermal relay
trips after a short
time of operation.
a) The temperature of the pumped
liquid is too high.
Contact your Grundfos
representative.
b) The impeller is blocked or partly
blocked by impurities.
Clean the impeller.
See section 7.1 Cleaning the
pump.
c) Phase failure. Consult an electrician.
d) The voltage is too low. Consult an electrician.
e) The overload setting of the motor-
protective circuit breaker is set too
low.
Adjust the setting.
3. The pump runs
constantly or
gives insufficient
water.
a) The pump is partly blocked by
impurities.
Clean the pump.
See section 7.1 Cleaning the
pump.
b) The outlet pipe or valve is partly
blocked by impurities.
Clean the outlet pipe or valve.
c) The impeller is not properly fixed to
the shaft.
Tighten the impeller.
d) The float switch is set incorrectly. Adjust the float switch setting.
e) The pump is too small for the
application.
Replace the pump.
f) The impeller is worn. Replace the impeller.
16
English (US)
9. Technical data
Enclosure class
IP68.
Insulation class
F (311 °F / 155 °C).
9.1 Operating conditions
Minimum liquid temperature
32 °F (0 °C).
Maximum liquid temperature
122 °F (50 °C) in continuous operation.
Minimum water level
The water level must be above the inlet strainer.
Maximum installation depth
30 ft (10 m) below liquid level.
Maximum starts per hour
20 starts, evenly distributed once every 3
minutes.
pH value
Between 4 and 10.
Maximum particle size
Density
Maximum 68 lbs/ft
3
(1100 kg/m
3
).
Viscosity
Maximum 10 cSt (centistoke) (10 mm
2
/s).
Operation
The inlet strainer must always be covered by the
pumped liquid. The pump can run continuously.
See the nameplate on the pump for the electrical
and hydraulic performance data.
9.2 Sound pressure level
The sound pressure level of the pump is lower
than the limiting values stated in the EC Council
Directive 2006/42/EC relating to machinery.
A-weighted sound pressure level
< 65 dB (A) in accordance with ISO 3743.
For further technical data, see sections
6.2.1 Nameplate and 6.2.2 Type key.
9.3 Storage
Storage temperature
Not lower than -22 °F (-30 °C).
10. Disposing of the product
This product or parts of it must be disposed of in
an environmentally sound way:
1. Use the public or private waste collection
service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Subject to alterations.
4. The pump runs
but gives no
water.
a) The pump is blocked by impurities. Clean the pump.
See section 7.1 Cleaning the
pump.
b) The outlet pipe or the non-return
valve is blocked by impurities.
Clean the outlet pipe or the non-
return valve.
c) The impeller is not properly fixed to
the shaft.
Tighten the impeller.
d) Air is trapped in the pump. Vent the pump and the outlet
pipe.
e) The liquid level is too low. The inlet
strainer is not completely
submerged in the pumped liquid.
Submerge the pump in the liquid
or adjust the float switch.
f) The float switch does not move
freely.
Make the float switch move freely.
Fault Cause Remedy
Pump type Max. spherical diameter
Unilift AP12 0.47 in. (12 mm)
Unilift AP35 1.38 in. (35 mm)
Unilift AP50 1.97 in. (50 mm)
17
Français (CA)
Français (CA) Notice d'installation et de fonctionnement
Traduction de la version anglaise originale
La présente notice d'installation et d'utilisation
décrit les produits Grundfos Unilift AP12, AP35
et AP50.
Les paragraphes 1 à 5 fournissent les informa-
tions nécessaires pour déballer, installer et
démarrer le produit en toute sécurité.
Les paragraphes 6 à 10 donnent des informa-
tions importantes sur le produit, ainsi que sur la
maintenance, le dépannage et la mise au rebut
du produit.
SOMMAIRE
Page
1. Garantie limitée
18
2. Généralités
18
2.1 Symboles utilisés dans ce document
18
2.2 Dessin général
19
3. Réception du produit
19
3.1 Inspection du produit
19
3.2 Livraison
19
4. Installation du produit
19
4.1 Raccordement de la tuyauterie
20
4.2 Espace restreint
20
4.3 Lieu d'installation
20
4.4 Réglage de la longueur du câble pour
l'interrupteur à flotteur
21
4.5 Branchement électrique
21
5. Démarrage du produit
22
5.1 Démarrage
22
6. Introduction au produit
23
6.1 Applications
23
6.2 Identification
25
6.3 Fonctions
25
6.4 Composants de la pompe
25
7. Entretien et réparation du produit
26
7.1 Nettoyage de la pompe
27
7.2 Pompes contaminées
27
7.3 Remplacement de pièces
27
8. Détection des défauts de fonctionne-
ment
28
9. Caractéristiques techniques
29
9.1 Conditions de fonctionnement
29
9.2 Niveau de pression sonore
29
9.3 Stockage
29
10. Mise au rebut du produit
29
Avant de procéder à l'installation, lire
attentivement cette notice. L'installa-
tion et le fonctionnement doivent être
conformes à la réglementation locale
et aux règles de bonne pratique en
vigueur.
Un bon fonctionnement dépend de
l'attention particulière accordée aux
procédures décrites dans ce manuel.
Conservez ce manuel pour une utili-
sation future.
18
Français (CA)
1. Garantie limitée
Les produits fabriqués par Grundfos Pumps Cor-
poration (Grundfos) sont garantis, uniquement
pour l'utilisateur initial, exempts de défauts de
matériaux et de fabrication pour une période de
24 mois à compter de la date d'installation, mais
au plus 30 mois à compter de la date de fabrica-
tion. Dans le cadre de cette garantie, la respon-
sabilité de Grundfos se limite à la réparation ou
au remplacement, à la convenance de
Grundfos, sans frais, FOB de l'usine Grundfos
ou d'un atelier de maintenance autorisé, de tout
produit de fabrication Grundfos. Grundfos
n'assume aucune responsabilité quant aux frais
de dépose, d'installation, de transport ou pour
toute autre charge pouvant survenir en relation
avec une réclamation au titre de la garantie.
Les produits vendus mais non fabriqués par
Grundfos sont couverts par la garantie fournie
par le fabricant des dits produits et non par la
garantie de Grundfos.
Grundfos n'est responsable ni des dommages ni
de l'usure des produits causés par des condi-
tions d'exploitation anormales, un accident, un
abus, une mauvaise utilisation, une altération ou
une réparation non autorisée ou par une installa-
tion du produit non conforme aux notices d'ins-
tallation et de fonctionnement imprimées de
Grundfos ainsi qu'aux codes de bonnes pra-
tiques communément acceptés. La garantie ne
couvre pas l'usure normale.
Pour bénéficier de la garantie, il faut renvoyer le
produit défectueux au distributeur ou au reven-
deur de produits Grundfos chez qui il a été
acheté, accompagné de la preuve d'achat, de la
date d'installation, de la date du dysfonctionne-
ment ainsi que des données concernant l'instal-
lation. Sauf disposition contraire, le distributeur
ou le revendeur contactera Grundfos ou un ate-
lier de maintenance autorisé, pour obtenir des
instructions. Tout produit défectueux renvoyé à
Grundfos ou à un atelier de maintenance doit
être expédié port payé ; la documentation rela-
tive à la déclaration de sinistre et à une autorisa-
tion de retour de matériel éventuelle doit être
jointe, si elle est demandée.
Grundfos n'assume aucune responsabilité en
cas de dommages indirects ou consécutifs, de
pertes ou de dépenses résultant de l'installation,
de l'utilisation ou de toute autre cause. Il n'existe
aucune garantie, explicite ni implicite, y compris
la qualité marchande ou l'adéquation pour un
usage particulier, en dehors des garanties
décrites ou mentionnées ci-dessus. Certaines
juridictions n'autorisent pas l'exclusion ou la
limitation des dommages indirects ou consécu-
tifs, et certaines juridictions ne permettent pas
de limiter la durée des garanties implicites. Il se
peut donc que les limitations ou exclusions men-
tionnées ci-dessus ne soient pas applicables
dans votre cas. Cette garantie vous donne des
droits légaux spécifiques. Il se peut que vous
ayez également d'autres droits qui varient d'une
juridiction à l'autre.
Les produits qui sont réparés ou remplacés par
Grundfos ou par atelier de maintenance auto-
risé, en vertu des dispositions de ces conditions
de garantie limitée, continueront à être couverts
par la garantie Grundfos uniquement pendant le
reste de la période de garantie initialement fixée
à la date d'achat d'origine.
2. Généralités
2.1 Symboles utilisés dans ce document
2.1.1 Avertissements contre les dangers avec
risques de blessures ou de mort
Le texte qui accompagne les trois symboles
DANGER, AVERTISSEMENT et PRUDENCE
est structuré de la façon suivante :
2.1.2 Autres remarques importantes
DANGER
Indique une situation dangereuse qui,
si elle n'est pas évitée, entraînera des
blessures graves ou la mort.
AVERTISSEMENT
Indique une situation dangereuse qui,
si elle n'est pas évitée, peut entraîner
des blessures graves ou la mort.
PRUDENCE
Indique une situation dangereuse qui,
si elle n'est pas évitée, peut entraîner
des blessures légères ou modérées.
TERME DE
SIGNALEMENT
Description du danger
Conséquence de la non-observance
de l'avertissement.
- Mesures pour éviter le danger.
Un cercle bleu ou gris autour d'un pic-
togramme blanc indique qu'il faut agir.
Un cercle rouge ou gris avec une
barre diagonale, éventuellement avec
un symbole graphique noir, indique
qu'une mesure ne doit pas être prise
ou doit être arrêtée.
Le non-respect de ces consignes peut
entraîner des dysfonctionnements ou
endommager l'équipement.
Conseils et astuces pour faciliter les
opérations.
19
Français (CA)
2.2 Dessin général
Fig. 1 Pompe Unilift AP
3. Réception du produit
3.1 Inspection du produit
Vérifier que le produit reçu est conforme à la
commande.
Vérifier que la tension et la fréquence du produit
correspondent à la tension et à la fréquence du
site d'installation.
3.2 Livraison
L'emballage contient les éléments suivants :
pompe ;
câble d'alimentation ;
interrupteur à flotteur (si inclus avec ce
modèle) ;
une notice d'installation et de fonctionne-
ment.
4. Installation du produit
TM03 6189 4406
PRUDENCE
Écrasement des pieds
Blessure mineure ou modérée
- Porter des chaussures de sécurité
lors de la manipulation du produit.
- Utiliser la poignée de la pompe
pour la déplacer. Ne pas utiliser le
câble électrique pour soulever la
pompe.
Orifice de
refoulement
Gaine de
pompe
Crépine
d'aspiration
Poignée avec
attache
Interrup-
teur à
flotteur
DANGER
Choc électrique
Blessures graves ou mort
- L'installation, le raccordement
électrique et la maintenance du
produit doivent être effectués par
un électricien qualifié conformé-
ment au Code national de l'électri-
cité, et en tout état de cause
conformément aux codes locaux et
aux réglementations locales.
DANGER
Choc électrique
Blessures graves ou mort
- Avant toute intervention sur le pro-
duit, couper l'alimentation élec-
trique.
- S'assurer que l'alimentation élec-
trique ne risque pas d'être bran-
chée accidentellement.
DANGER
Choc électrique
Blessures graves ou mort
- L'installation de la pompe dans un
puisard, un bassin ou une fosse
doit être effectuée par des per-
sonnes qualifiées et spécialement
formées, conformément au Code
national de l'électricité, et en tout
état de cause conformément aux
codes locaux et aux réglementa-
tions locales.
AVERTISSEMENT
Pièces en mouvement
Blessure mineure ou modérée
- Veiller à ce que personne ne
puisse entrer en contact avec des
pièces en mouvement.
Ne pas soulever la pompe par le
câble d'alimentation, par la tuyauterie
de refoulement ou le flexible.
Si la pompe est installée dans un
puits ou une fosse, la faire descendre
et la soulever à l'aide d'un câble ou
d'une chaîne fixée à la poignée de la
pompe.
20
Français (CA)
4.1 Raccordement de la tuyauterie
Les conduits en acier fileté ou en plastique
rigide peuvent être vissés directement dans l'ori-
fice de refoulement 1,5" NPT. Pour une installa-
tion fixe, il est conseillé d'installer un raccord, un
clapet de non-retour et un clapet d'isolement
dans le conduit de refoulement.
Autres recommandations :
Pour les installations temporaires ou
mobiles, un conduit de refoulement en plas-
tique peut être utilisé avec un raccord vissé
ou un raccord pour flexible adapté.
Sceller les filetages à l'aide de ruban adhésif
Teflon
®
.
4.2 Espace restreint
Une fois la pompe installée dans un équipement
fixe avec interrupteur à flotteur, et la longueur de
câble réglée à la valeur minimale de 4 po (100
mm), les dimensions minimales du puisard, du
bassin ou de la fosse doivent être celles indi-
quées en fig. 2.
En outre, le puisard, la fosse ou le bassin doit
être dimensionné en fonction du rapport entre le
débit d'eau du puisard, du bassin ou de la fosse
et la performance de la pompe.
Fig. 2 Dimensions d'installation minimales
4.3 Lieu d'installation
La pompe peut être utilisée verticalement ou
horizontalement avec la sortie d'évacuation
comme point le plus haut de la pompe. Voir fig.
3.
Pendant le fonctionnement, la crépine d'aspira-
tion doit toujours être entièrement recouverte
par le liquide pompé.
Fig. 3 Positions de la pompe
Une fois le conduit ou le flexible branché, placer
la pompe dans sa position de fonctionnement.
Positionner la pompe de façon à ce que la cré-
pine d'aspiration ne risque pas d'être bouchée
par de la boue ou des matériaux similaires.
Pour les installations fixes, le site d'installation
doit être débarrassé de la boue, des cailloux,
etc., avant l''installation de la pompe.
Il est recommandé de placer la pompe sur une
fondation solide. Voir fig. 4.
Fig. 4 Pompe placée sur une plaque
DANGER
Choc électrique
Blessures graves ou mort
- Acheminer le câble d'alimentation
de manière à ce qu'il le supporte et
qu'il soit protégé contre le risque
d'être coupé, pincé ou endom-
magé.
- Si le câble d'alimentaion est coupé,
pincé ou endommagé, le remplacer
avant d'utiliser le produit.
DANGER
Choc électrique
Blessures graves ou mort
- Ne pas retirer le câble d'alimenta-
tion et le réducteur de tension.
- Ne pas raccorder le conduit élec-
trique à la pompe.
Utiliser un régulateur de niveau
approuvé avec un courant nominal
correspondant au facteur de service
indiqué sur la plaque signalétique du
produit.
Ne pas installer la pompe en la sus-
pendant au conduit de refoulement ou
au flexible.
Ne pas soulever la pompe par le
câble d'alimentation. Abaisser et sou-
lever la pompe avec une chaîne ou un
câble fixé à la poignée de la pompe.
TM03 6194 4406
TM03 6193 4406
TM03 3691 4406
‹‹
‹‹
550 mm
600 mm
21,5 po (550 mm)
23,5 po
(600 mm)
••
••
••
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48