Impecca Window Air Conditioner
Users Manual
Model:
IWA05-KR15 - 5000 BTU
v.0.6
www.impecca.com
WARNING:
To avoid permanent damage to unit:
Ensure it is in the upright position for a MINIMUM of 6
hours and a RECOMMENDED time of 24 hours before
powering on the first time.
ADVERTENCIA:
Para evitar daños permanentes a la unidad:
Asegúrese de que está en la posición vertical durante
un mínimo de 6 horas y un tiempo recomendado de 24
horas antes de encender la primera vez.
Read the following notices and information carefully to ensure proper operation of your
air conditioner unit.
This manual is solely provided for informational purposes and in no way constitutes a
legally binding document between the manufacturer, distributor, and end consumer. Ex-
act appearance of your unit may dier from the pictures and diagrams enclosed.
Lea las siguientes indicaciones cuidadosamente para asegurar el correcto funciona-
miento de su unidad de aire acondicionado.
Este manual se proporciona únicamente con fines informativos y de ninguna mane-
ra constituye un documento jurídicamente vinculante entre el fabricante, distribui-
dor y consumidor final. Apariencia exacta de su unidad puede diferir de las imágenes
y esquemas adjuntos.
Spanish version of this manual available for download on
www.impecca.com
ENGLISH
–3–
TABLE OF CONTENTS
Introduction ..............................................................................................................................6
Getting To Know Your Air Conditioner ..................................................................................7
Using Your Air Conditioner .....................................................................................................7
Delay Start/Stop (Timer) ...................................................................................................... 11
Pre-installation instructions................................................................................................ 12
Installation Instructions ...................................................................................................... 14
Cleaning & Maintenance ...................................................................................................... 18
Troubleshooting .................................................................................................................... 19
Electrical Information ........................................................................................................... 21
Customer Support ................................................................................................................. 21
One-Year Limited Appliance Warranty (US) ...................................................................... 22
Garantía Limitada Por Un Año (US) ................................................................................... 23
Garantie Limitée D’un An (US) ............................................................................................ 24
ENGLISH
–4–
Plug in power plug completely.
Do not start or stop the unit by inserting or
pulling out the power plug.
Do not damage power cord or replace
with a non-original power cord.
• Otherwise, it may cause electric shock or
fire due to potential short circuit.
• It may cause electric shock or fire.
• It may cause electric shock or fire.
• If the power cord is damaged, it must
be replaced by the manufacturer or an
authorized service center or a similarly
qualified person to avoid hazard.
Do not modify power cord length.
Do not operate with wet hands or in a
damp environment.
Do not direct airflow directly at room
occupants.
• It may cause electric shock or fire. • It may cause electric shock. • This could be harmful to their health.
Always ensure eective grounding/
earthing.
Do not allow water into or onto the front of
cabinet, control panel or power cord.
Always use dedicated power outlet and
circuit breaker.
• Incorrect or missing grounding may lead to
electric shock.
• It may cause failure of unit or electric shock. • Sharing a circuit can lead to fire.
Unplug the unit if it emits strange sounds,
smells or smoke.
Do not plug unit into an electrical socket
that is loose or damaged.
Do not operate the unit while the
chassis is open or removed.
• Unit may need repair. • It may cause fire and electric shock. • It may cause electric shock.
Ensure the power cord is kept away from
any heating sources.
Do not disassemble or modify unit.
Do not use the power cord near
flammable gas or combustibles, such as
gasoline, benzene, paint thinner, etc.
• It may cause fire and electric shock. • It may cause failure and electric shock. • It may cause an explosion or fire.
Ventilate room before operating
air conditioner if there was a gas leakage.
• It may cause explosion, fire, and burns.
WARNING
READ THESE NOTICES CAREFULLY—THEY ARE IMPORTANT!
When the air filter is removed for cleaning,
avoid touching the internal metal parts of
the unit.
Do not clean the air conditioner with water.
Ventilate the room well when used
together with a stove, etc.
• It may cause an personal injury and/or
damage to the unit.
• Water may enter the unit and degrade the
insulation. It may cause an electric shock.
• An oxygen shortage may occur when
using a stove in a room with closed
windows.
When the unit is to be cleaned, power o
the unit and circuit breaker.
Do not put a pet or house plant where it
will be exposed to direct air flow.
Do not use for specialized purposes.
• Do not clean unit when power is on as it
may cause fire and electric shock and/or
personal injury.
• This could injure or be harmful
to your pet or plants.
• Do not use this air conditioner to
preserve precision devices, food, pets,
plants, and art objects.
• It may cause deterioration, etc.
CAUTION
ENGLISH
–5–
CAUTION
ELECTRICAL SAFETY
• Be sure your electrical wiring is adequate for the model you have chosen. This information can be found
on the rating label, a silver-colored sticker generally located on the right side of the cabinet.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding
is important. The power cord is equipped with a three-prong grounding plug for protection against
shock hazards.
• Your air conditioner must be connected to a properly
grounded wall receptacle. If the wall receptacle you intend
to use is not adequately grounded or protected by a time
delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle.
• Ensure the receptacle is accessible aer the unit installation.
Stop operation and remove unit from
window in severe storm or hurricane.
Hold the plug by the head of the power
plug when unplugging unit.
Unplug the power cord when not using
the unit for extended periods of time.
• Operation during a severe storm may allow
a significant amount of water to enter the
indoors.
• Pulling from the wire can cause wire to fray
leading to electric shock or fire.
• Will prevent damage to the unit.
Do not place obstacles around air-intake
vents or inside cool air outlet.
If unit is equipped with an outdoor
installation bracket, periodically ensure that
it has not become damaged.
Always insert the filters securely.
Clean filter at least once per month.
• It may cause failure of appliance.
• If bracket is damaged, the unit can fall and
cause damage, personal injury or death.
• Operation with dirty filters (or without
filters) will eect performance and may
cause damage to the unit.
Do not use strong detergent such as
wax or paint thinner to clean the unit.
Use a damp, so cloth.
Do not place heavy objects on the
power cord and ensure that the cord
is not pinched or stressed.
Do not place this window-type air
conditioner through a wall.
• Appearance may deteriorate due to change
of product color or scratching of its surface.
• There is danger of fire or electric shock.
• This will block the side vents and pre-
vent the unit from cooling properly.
CAUTION
NOTE: The power supply cord with this air conditioner
contains a current detection device designed to reduce the risk
of fire. In the event that the power supply cord is damaged, it
cannot be repaired -- it must be replaced with a cord from the
Product Manufacturer.
The power supply cord contains a current device that senses damage
to the power cord and excess current draw from the unit. To test your
current device do the following:
1. Plug in the Air Conditioner.
2. Press the TEST button. You will hear a click as the RESET button
pops out within the rubber housing and the LED will turn o.
3. Press the RESET button. You will hear a click as the button
engages and the LED will illuminate.
4. The power supply cord is now supplying electricity to the unit.
Note: Your model may have the TEST and RESET buttons on the
side or the front of the plug head.
NOTES:
• Do not use the TEST and RESET buttons to turn the unit on or o.
• If the current device fails the test or the power cord becomes dam-
aged, the entire power cord must be replaced with an equivalent
power cord and current device by a licensed electrician.
Side button
version
ENGLISH
–6–
INTRODUCTION
Thank you for purchasing this quality Impecca window air conditioner unit. To ensure
the longest life and highest energy eiciency of your unit, please carefully follow these
operating instructions. Keep these instructions in a safe place and consult them as
needed. Please note that constant enhancement and improvements to our air con-
ditioning units may mean that your model will slightly dier in appearance from the
model pictured in this manual, but the actual operation and installation of the unit
remains unchanged. This manual is solely provided for informational purposes and
does not constitute a binding, legal contract.
SAFETY NOTICE:
This appliance should not be used by children or mentally/physically disabled persons
without strict, direct supervision by a responsible adult. Never play with or around the
appliance.
SAFETY INFORMATION
Before operation, ensure your electrical installation (outlets and circuits) complies
with the power specifications found on the unit.
Before cleaning or maintaining the air conditioner, please turn o air conditioner
and unplug the unit.
Make sure the power cord isn’t kinked, bent, or under the weight of sharp or heavy
objects.
Do not pull or yank the power cord to unplug the unit or move the air conditioner.
Do not insert or unplug the power plug with wet hands.
Only use a grounded power outlet. Make sure the grounding is functional.
If the power cord is damaged, it must be replaced by the manufacturer or a quali-
fied technician in order to avoid fire and electrical hazards.
Should abnormal operation occur (such as a burning smell), please disconnect
power cord immediately and contact your local dealer.
If nobody is present to monitor the operation of the unit, please turn it o and dis-
connect the power cord.
Do not splash or pour water on air conditioner to avoid causing a short circuit or
damage to the unit.
Do not put or hang dripping objects above the air conditioner.
Ensure the ambient temperature remains well above freezing (32°F or 0°C) to avoid
cracking or damaging the unit.
Keep heat sources away from the air conditioner.
Ensure the unit is far away from fire, inflammable, or explosive objects.
Never allow children or persons with reduced physical, sensory, or mental capabili-
ties to operate or play around the air conditioner without direct adult supervision.
Never allow children to perform cleaning or other user-maintenance operations
without direct adult supervision.
Never attempt to repair or disassemble the air conditioner by yourself.
Never insert objects into the air conditioner.
ENGLISH
–7–
OPERATING CONDITIONS
The air conditioner must be operated within the temperature range of 62°F to 95°F
(16°C to 35°C).
A perimeter of 12′′(30cm) around the air conditioner should be free of all objects.
Keep air inlet and air outlet clean and free of obstructing objects.
During operation, close doors and windows to improve cooling eect.
Please put the air conditioner at smooth and flat ground for operation to avoid
noise and vibration.
Do not tilt or turn over the air conditioner. If there’s problem, please disconnect the
power supply immediately and contact your local dealer or technical support.
GETTING TO KNOW YOUR AIR CONDITIONER
1. Cool air outlet
2. Cool air directional
lever(s)
3. Control Panel
4. Warm air intake
5. Filter grasp
6. Outside air intake
(Do not block these
vents!)
USING YOUR AIR CONDITIONER
AIRFLOW
The louvers allow le and right airflow adjustment via the lever or levers located to-
wards the bottom of the cool air outlet
THREE-MINUTE DELAY
Aer turning your unit o and on again right away, there will be a three-minute delay
before the compressor begins operating again.
PMTS
E
D
C
G
F
B
Lever
Lever
ENGLISH
–8–
OVERVIEW OF CONTROLS AND FUNCTIONS
Before you begin, thoroughly familiarize yourself with the control panels as shown below
and all its functions, then follow the symbol for the functions you desire. The unit can be
controlled by the unit control panel located on the front of the device or with the remote
controller.
1. Temperature/Timer Down
2. Timer (Delay start/stop)
3. Check Filter light reset
4. Function selector (Auto-Cool-Dry-Fan)
5. Energy Saver
6. On/O
7. Infrared Remote senor window
8. Fan Speed selector
9. Sleep mode
10. Display (Temperature/Timer)
11. Temperature/Timer Up
Note that your model's control panel may
dier slightly.
POWER ON/OFF
Press the On/O button to turn the unit on or
o.
Control Panel
B
C
D
E
F
G
H
I
J
K
L
ENGLISH
–9–
TEMPERATURE ADJUSTMENT
Press or hold either Down or Up button until the
desired temperature is seen on the display. This tempera-
ture will be automatically maintained anywhere between
62° F (17° C) and 86° F (30° C).
If you want the display to read the actual room tempera-
ture, refer to the note: “To Operate on Fan Only.
FAN SPEED ADJUSTMENT
Select the Fan Speed in four steps: Auto, Low, Med or
High. Each time the button is pressed, the fan speed
mode is shied. On Dry mode, the fan speed is controlled
at Low automatically.
OPERATING MODE (FUNCTION) SELECTION
To choose operating mode, press the Mode button. Each
time you press the button, a mode is selected in a se-
quence that goes from AUTO, COOL, DRY, and FAN. The
indicator light beside will be illuminated and will remain
on once the mode is selected.
USING AUTO FEATURE
When you set the air conditioner in AUTO mode, it will
automatically select cooling or fan only operation de-
pending on the current room temperature and the target
temperature you have set. The air conditioner will control
room temperature automatically. In this mode, the fan
speed cannot be adjusted.
USING DRY MODE
In this mode, the air conditioner will generally operate in
the form of a dehumidifier. Since the conditioned space is a
closed or sealed area, some degree of cooling will continue.
FAN ONLY MODE
Use this function only when cooling is not desired, such
as for room air circulation or to exhaust stale air (on some
models). Remember to open the vent during this function,
but keep it closed during cooling for maximum cooling
eiciency. You can choose any fan speed you prefer.
During this function, the display will show the actual room
temperature, not the set temperature as in the cooling
mode. In Fan Only mode, the temperature is not adjusted.
ENGLISH
–10–
ENERGY SAVER MODE
This function is available on COOL mode. The fan will con-
tinue to run for 3 minutes aer the compressor shuts o.
The fan then cycles on for 2 minutes at 10-minute intervals
until the room temperature is above the set temperature,
at which time the compressor turns back on and Cooling
Starts. Note that due to modern energy saving regula-
tions, this mode is on by default and you must turn it o if
you want the fan to run constantly during cooling mode.
SLEEP MODE
In this mode the selected temperature will increase by 2°F
(or 2°C) 30 minutes aer the mode is selected. The tem-
perature will then increase by another 2°F (or 2°C) aer an
additional 30 minutes. This new temperature will be main-
tained for 6 hours before it returns to the originally select-
ed temperature. This ends the Sleep mode and the unit
will continue to operate as originally programmed. The
Sleep mode program can be canceled at any time during
operation by pressing the Sleep button again.
CHECK FILTER
This feature is a reminder to clean the Air Filter for more
eicient operation. The LED (light) will illuminate aer
250 hours of operation. To reset aer cleaning the filter,
press the Check Filter button and the light will go o. See
section under Cleaning and Maintenance for how to clean
the filter.
Note: Your filter may need to be cleaned much more oen
in especially dusty environments and may not need to be
cleaned as oen in especially clean environments. The 250
hour indicator is just there as a reminder.
Ion
ENGLISH
–11–
DELAY START/STOP (TIMER)
The timer buttons enable two separate functions: one to
automatically start the unit within a 24 hour period of time
and another to automatically turn o the unit within a 24
hour period of time. These functions are called, respectively,
AUTO ON and AUTO OFF.
AUTO ON INSTRUCTIONS:
1. Press the TIMER button twice, or until the TIMER
ON LED on the air conditioner's control panel should
illuminate. The air conditioner's display shows the last
Auto-On setting (if any). Now you are ready to reset the
Auto-On time to START the operation.
2. Press either the orbuttons to set desired Auto-On time. Each time you press
the button, the time will increase in 30 minute increments, up to 10 hours, then
in 1 hour increments up to 24 hours.
3. Aer setting the TIMER ON, there will be a one-half second delay before the
remote controller transmits the signal to the air conditioner. Then, aer approxi-
mately another 2 seconds, the time setting will disappear from the unit's display
and the set temperature will re-appear on the display window. The Timer ON LED
should remain illuminated.
AUTO OFF INSTRUCTIONS:
1. Press the TIMER button once, or until the TIMER OFF LED on the air condition-
er's control panel should illuminate. The air conditioner's display shows the last
Auto-O setting (if any). Now you are ready to reset the Auto-O time to START the
operation.
2. Press either the orbuttons to set desired Auto-O time. Each time you press
the button, the time will increase in 30 minute increments, up to 10 hours, then
in 1 hour increments up to 24 hours.
3. Aer setting the TIMER ON, there will be a one-half second delay before the
remote controller transmits the signal to the air conditioner. Then, aer approxi-
mately another 2 seconds, the time setting will disappear from the unit's display
and the set temperature will re-appear on the display window. The Timer OFF LED
should remain illuminated.
Notes: It is possible to set both and Auto-On and Auto-O program at the same time. All times that are set
are the time from the moment of setting. So if you were to set a delay of 5 hours to turn on and immediately
aer set a delay of 6 hours to turn o, then the unit will operate for a total of 1 hour in 5 hours time from now.
All programs are erased aer their time elapses, so they will not repeat again the next day until repro-
grammed.
Important: If you use a separate timer to obtain more control (such as turning on and o at a specific time every
day), the unit will remember its previous mode. It may, however, return to energy saver mode by default. If you
do use a timer, be sure that it is a heavy -duty grounded (three-prong) timer that is rated for the appropriate
amperage.
ENGLISH
–12–
1
2
3
7
9
8 11
4
3
5
6
10
PMTS
Phillips Screwdriver
Level
Scissors Pencil Tape Measure
PRE-INSTALLATION INSTRUCTIONS
REQUIRED TOOLS (NOT INCLUDED)
INCLUDED PARTS & ACCESSORIES*
1. Air conditioning unit
2. Flexible window filler panels
3. Upper Rail
4. Upper Rail seal (may already be at-
tached to bottom of rail)
5. Foam sash seal (no adhesive)
6. Foam seal (with adhesive)
7. Upper Rail Screws (x4)
8. ½” or ¾” Screws (x6)
9. Frame lock
10. Window security bracket
11. User’s manual and Remote Manual
*Note: The parts and appearance of parts
included with your unit may vary.
ENGLISH
–13–
WINDOW REQUIREMENTS
Your air conditioner is de-
signed to install in a standard
double hung windows with
opening widths of 23 to 36
inches (584mm to 914mm)
and a height of 13 inches min-
imum.
STORM WINDOW MODIFICATIONS
If you have storm windows, the exterior window frame will be slightly higher than the
windowsill, which results in an air conditioning unit that is slanted inward and may
cause water condensation to enter the room interior. Perform these modifications to
ensure proper operation of your unit. If you have a standard window, skip this step:
1. Cut a 2” thick piece of wood to the length of the interior window width.
2. Verify that the wood is level with or up to 0.5” (1cm) higher than the exterior
storm-window frame.
3. Fasten the wood with screws to the windowsill and proceed with mounting.
13”
Wooden Windows
INTERIOR
WALL
INNER
WINDOW SILL
EXTERIOR
WALL
OFFSET
5
8
4m
m
-
9
14
m
m
2
3
-
36”
Exterior Wall
Board thickness
should be as required
for proper pitch and
run along the entire
window sill. Fasten
with nails or screws.
Storm Window
or other obstruction
1½” min
(38 mm)
ENGLISH
–14–
Side louvers and the rear of the AC must have clear air space to allow enough airflow through the
condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or ga-
rage.
Note: Save original carton and these installation instructions for future reference. The carton is
the best way to store the unit during winter (or when the unit will not be used for an extended pe-
riod
CAUTION: When handling unit, be careful to avoid cuts from sharp metal edges and aluminum
fins on front and rear coils.
NOTE: Before installing unit, the top rail must be assembled on the unit.
TOP RAIL INSTALLATION
1. Remove the air conditioner from the carton and place on a flat surface.
2. Remove top rail from the rear of the packaging material as shown in Figure A.
INSTALLATION INSTRUCTIONS
Fig.
A
Packaging
Top Rail
ENGLISH
–15–
3. Align the hole in the top rail with those in
the top of the unit as shown in Figure B.
4. Secure the top rail to the unit with the ⅜”
screws as shown in Figure C.
Note: For safety reasons, all four (4) screws
MUST be securely fastened.
SIDE PANEL INSTALLATION
NOTE: Top rail and Sliding Panels at each side are oset to provide the proper pitch to the rear of
the unit (5/16”). This is necessary for proper condensed water utilization and drainage. If you are
not using the Side Panels for any reason, this pitch to the rear must be maintained.
1. Place unit on the floor, a bench, or a table. There is a Le and Right Window Filler Panel—be
sure to use the proper panel for each side. When installed, the flange for securing the panel in
place to the windowsill will be facing into the room.
Hold the Accordion Panel in one hand
and gently pull back the center to free the
open end. See Figure 2
Slide the free end of the panel
into the cabinet as shown in Fig-
ure 3A, 3B, and 3C. Slide the pan-
el down. Be sure to leave enough
space to slip the top and bottom
of the frame into the rails on the
cabinet.
ENGLISH
–16–
Once the panel has been installed on the
side of the cabinet, make sure it sits securely
inside the frame channel by making slight
adjustments. Slide the top and bottom ends
of the frame into the top and bottom rails of
the cabinet. Figure 4
Note: If storm window blocks AC, see Figure
13
2. Keep a firm grip on the air conditioner, and carefully place the unit into the window opening so
that the bottom of the air conditioner frame is against the windowsill (See Fig. 5). Carefully close
the window behind the top rail of the unit.
3. Extend the side panels out against the win-
dow frame (See Fig. 6).
4. Place the frame lock be-
tween the frame extensions
and the windowsill (as shown in
Fig. 7).
Drive ¾” (19mm) or ½(13mm)
locking screws through the
frame lock and into the sill ( See
Fig. 8).
Note: To prevent windowsill
from splitting, drill 1/8” (3mm)
pilot holes before driving
screws.
ENGLISH
–17–
5. Drive ½” (13mm) locking screws through frame holes into window sash (See Fig. 9 and Fig. 10).
6. To secure lower sash in place, attach right angle sash lock with 3/4” (19mm) or ½” (13mm) screw
as shown. (See Fig.11).
7. Cut foam seal and insert in the space be-
tween the upper and lower sashes (See Fig. 12)
REMOVING AC FROM WINDOW
Turn AC o and disconnect power cord.
Remove sash seal from between windows and unscrew safety lock.
Remove screws installed through frame and frame lock.
Close (slide) side panels into frame.
Keeping a firm grip on air conditioner, raise sash and carefully “rock” air conditioner backward to
drain any condensation in the base of the unit. Be careful not to spill any remaining water while li-
ing unit from the window.
ENGLISH
–18–
CLEANING & MAINTENANCE
SAFETY WARNING
To avoid electric shock, fire, damage, or injury while performing maintenance on your
unit:
Always turn o and disconnect the air conditioner from electric power.
Never submerge the unit in water or spray liquids directly on the unit.
Never use solvents or other flammable or volatile liquids (examples: paint thinner,
acetone, gasoline, etc.) to clean the air conditioner.
PRE-COOLING SEASON UNIT CHECK
Before using your air conditioner in the warm summer months, always perform the
following verifications to ensure reliable, eicient operation:
Check the air inlets and outlets for any foreign objects (example: leaves, sticks,
small toys, etc.)
Check that the electrical cord and socket are not damaged, bent, or fraying.
Check the filter and clean if necessary.
POST-COOLING SEASON UNIT CHECK
Aer using your air conditioner in the warm summer months, always perform the
following verifications:
Disconnect the unit electrical power.
Clean the filter and unit casing.
Remove dust and other objects on the unit.
Discard any accumulated water inside the unit (see section about drainage).
LONG-TERM STORAGE
Should you place your unit in long-term storage, perform all of the post-season
checks listed above and perform the following additional steps:
Wrap the electrical cord loosely around the unit.
Cover the unit with a sheet or cloth to prevent dust buildup inside during storage.
• WARNING: Never store the unit up-side down or on its side. This can permanently
damage the compressor.
DISPOSAL INFORMATION
Most unit packaging materials are recyclable. Please dispose of them according to
local recycling guidelines.
If you wish to discard the unit, contact your local authorities for specific appliance
disposal instructions. If the unit is functional and in good repair, but you wish to
dispose of it, consider donating it to a local charity.
ENGLISH
–19–
CLEANING THE OUTER HOUSING AND INTAKE GRILLE
If dust has accumulated on the unit, use a so, dry dusting cloth to wipe it o. If
grease or other harder to remove substances is on the unit, use a wrung-out cloth
dampened with warm, soapy water. Use a so brush to clean o the grille.
CLEANING THE FILTER
For energy eicient operation, your filter should be cleaned at least once a month.
Units in dusty environments may require
more frequent filter cleaning.
The filter simply slides out the right
side of your unit.
Use a vacuum cleaner or rinse the fil-
ter in cold water. If the filter is partic-
ularly dirty (such as grease buildup),
wash and gently scrub the filter in a
bath of warm (not hot) soapy water.
Let the filter completely dry in a shady
place; exposing the filter to direct
sunlight can cause deformation.
Aer the filter is clean and completely
dry, re-insert the filter.
Note: To avoid deformation and fire risk, never dry the filter with a heat source, such as a
hair dryer, fireplace, or heater.
TROUBLESHOOTING
PROBLEM / POSSIBLE CAUSES
THE AIR CONDITIONER DOES NOT FUNCTION AT ALL
Is the power cable properly inserted into a functioning, grounded outlet?
Is there a power failure such as a blown fuse or tripped circuit breaker?
Is the ambient temperature lower than 61°F (16°C)? A safety device prevents the
unit from cooling the room to even lower temperatures.
INSUFFICIENT COOLING
Is the unit temperature set properly?
Is the air filter dirty?
Are doors or windows open?
Is the room directly exposed to sunlight or are there other heat sources in the
room?
Are there a large number of people in the room?
ENGLISH
–20–
WATER BUILD-UP IN THE UNIT, SPLASHING NOISE
This is not a problem. This self-evaporative unit is designed allow condensate to
build up in the rear of the unit during cooling and dry modes. The rear fan then
runs through the pool of water, splashing it upon the evaporator coils, helping to
cool them down. This makes the unit more eicient and eliminates the need to
hook up a drain hose.
THE AIR CONDITIONER UNIT STARTS AND STOPS VERY FREQUENTLY.
Verify the rating of your electrical system and outlets. You may need a qualified
electrician to troubleshoot and upgrade your electrical circuits if your air condition-
er unit exceeds the rated capacity.
FOG BLOWS OUT DURING COOLING
In warm, high humidity environments this may naturally occur. Continued cooling
will remove excess humidity from the room and the fog will disappear.
THE UNIT EMITS A STRANGE SMELL
This may be caused by residue from cooking and cigarette smoke, etc. that remain
in the air conditioning unit. Eliminated the source of the smell and clean the filter.
THE UNIT MAKES LOUD OR UNUSUAL NOISES AND VIBRATIONS
Ensure that the unit is installed according to the installation instructions above.
THERE IS A “SQUEALING” NOISE
The cycling of the refrigerant inside the unit can temporarily cause this noise.
THERE IS A “PATTING” NOISE
This is oen caused by heat expansion in the plastic parts.
CONDENSATION FORMS AT THE COOL AIR OUTLET
High humidity environments may cause condensation at the air flow output. Wipe
the condensation o with a sponge or dry cloth.
IF ANY OF THE FOLLOWING PHENOMENA OCCUR DESPITE THE ABOVE TROU-
BLESHOOTING TECHNIQUES, PLEASE TURN OFF THE UNIT AND DISCONNECT
THE POWER CORD IMMEDIATELY AND CONTACT TECHNICAL SUPPORT OR A
QUALIFIED TECHNICIAN:
The fuse blows or circuit breaker trips frequently.
The power cable is abnormally hot.
The insulation of the power cable is ripped, shred or torn.
The unit controls do not work.
The unit produces abnormal noises.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Impecca IWA05-KR15 Mode d'emploi

Catégorie
Climatiseurs mobiles
Taper
Mode d'emploi

dans d''autres langues