Zephyr AK1200BB Hood User Manual

Catégorie
Hottes
Taper
Hood User Manual

Ce manuel convient également à

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
JUN17.0201 © Zephyr Ventilation LLC.
Breeze I
Breeze II
Breeze I
AK1124x, AK1100x, AK1136x
Breeze II
AK1200Bx, AK1236Bx
READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS ....................................................... 4
INSTALLATION
Ducting Calculation Sheet
....................................... 5
Mounting Height & Clearance
................................ 6
Ducting Options
........................................................... 7
6SHFL¿FDWLRQV
............................................................... 8
Preparing Electrical
.................................................... 9
Preparing Electrical and Ducting
.......................... 10
Converting to Air Recirculating Mode
................. 11-12
Mounting the Range Hood ............................. 13
FEATURES & CONTROLS
Controls & Features
................................................... 14
MAINTENANCE
Cleaning and Filter Removal
.................................. 15
Lights
................................................................................ 16
TROUBLESHOOTING
................................................................ 17
WIRING DIAGRAMS
................................................................... 18
LIST OF PARTS AND ACCESSORIES
.............................. 19
WARRANTY
.................................................................................... 20
PRODUCT REGISTRATION
.................................................... 21
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
E $OZD\VWXUQKRRG21ZKHQFRRNLQJDWKLJKKHDWRUZKHQÀDPLQJIRRG
F &OHDQYHQWLODWLQJIDQVIUHTXHQWO\*UHDVHVKRXOGQRWEHDOORZHGWRDFFXPXODWHRQIDQRU¿OWHU
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
H .HHSIDQ¿OWHUVDQGJUHDVHODGHQVXUIDFHVFOHDQ
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
D 6027+(5)/$0(6ZLWKDFORVH¿WWLQJOLGFRRNLHVKHHWRUPHWDOWUD\WKHQWXUQRIIWKHEXUQHU%(&$5()8/7235(9(17%8516
,IWKHÀDPHVGRQRWJRRXWLPPHGLDWHO\(9$&8$7($1'&$//7+(),5('(3$570(17
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
 7KH¿UHLVVPDOODQGFRQWDLQHGLQWKHDUHDZKHUHLWVWDUWHG
 7KH¿UHGHSDUWPHQWLVEHLQJFDOOHG
 <RXFDQ¿JKWWKH¿UHZLWK\RXUEDFNWRDQH[LW
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
D ,QVWDOODWLRQZRUNDQGHOHFWULFDOZLULQJPXVWEHGRQHE\TXDOL¿HGSHUVRQVLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHVDQGVWDQGDUGV
,QFOXGLQJ¿UHUDWHGFRQVWUXFWLRQ
E 6XI¿FLHQWDLULVQHHGHGIRUSRZHUFRPEXVWLRQDQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUHYHQW
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQGWKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQG
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI
*URXQG)DXOW,QWHUUXSWHUSURWHFWHGEUDQFKFLUFXLW
g. NEVER place a switch where it can be reached from a tub or shower.
h. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
NOT FOR USE OVER AN OUTDOOR GRILL.
CAUTION
7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV
attics, crawl spaces or garages.
For indoor use only.
Do not use over cooking equipment greater than 60,000 BTU/hr.
This hood is not intended to be used as a shelf.
OPERATION
$OZD\VOHDYHVDIHW\JULOOHVDQG¿OWHUVLQSODFH:LWKRXWWKHVHFRPSRQHQWVRSHUDWLQJEORZHUVFRXOGFDWFKRQWRKDLU¿QJHUV
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
 7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
,IFRGHVSHUPLWDQGDVHSDUDWHJURXQGZLUHLVXVHGLWLVUHFRPPHQGHGWKDWDTXDOL¿HGHOHFWULFLDQGHWHUPLQHWKDWWKH
ground path is adequate.
Do not ground to a gas pipe.
&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHQRWVXUHWKHUDQJHKRRGLVSURSHUO\JURXQGHG
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWVSXUFKDVH
and install appropriate connector if necessary.
List of Materials
4
www.zephyronline.com
MODELS: BREEZE I - AK1124x, AK1100x, AK1136x
BREEZE II - AK1200Bx, AK1236Bx
PARTS SUPPLIED
1 - Hood
$OXPLQXPPHVK¿OWHUV
2 - Halogen light bulbs, GU-10 35W, Breeze I Only
1 - LED Light Strip, 5W, Breeze II Only
´[´UHFWDQJXODUVWDUWLQJFROODUZLWKGDPSHUORFDWHGLQVLGHKRRGERG\
1 - Hardware package
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
&DEOHFRQQHFWRUif required by local codes
5HFLUFXODWLQJ.LW$.
M4 x 1” (4)
M4 x 1-1/2” (4)
M4 x 2” (4)
M4 x 8 (10)
Wood screw washers (4)
Wire Caps (3)
Light bulb removal
Suction Cup (1)
Breeze I Only
5
Installation – Ducting Calculation Sheet
Duct pieces
Tot a l
Equivalent number
length x used =
3- 1/4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
Tot a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” round to
3- 1/4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum 3-1/4” x 10” rectangular duct must be
XVHGWRPDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
$OVRXVHFDOFXODWLRQRQSDJHWRFRPSXWHWRWDO
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 24”.
Maximum mount height should be no higher than
32”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
3-1/4”x10” minimum
Horizontal Ducting:
3-1/4”x10” minimum
DAMAGE-SHIPMENT / INSTALLATION:
3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
36”
24” min.
32” max.
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZLWKFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Some Ducting Options
Installation – Ducting Options
Roof Pitch w/
Flashing & Cap
Rear Ducting
3-1/4”x10”
vertical ducting
3-1/4”x10”
horizontal ducting
Air Recirculating
8
www.zephyronline.com
Installation – 6SHFL¿FDWLRQV
35-15/16” (36”)
29-15/16” (30”)
23-15/16” (24”)
33-7/8” (36”)
27-7/8” (30”)
22-1/16” (24”)
33-5/8” (36”)
27-5/8” (30”)
21-5/8” (24”)
2-3/4”
C/L
8-5/8”
1-3/8”
9-1/16”
2”
12-3/16”
10-7/8”
3/4”
9-1/16”
elec.
k/o
elec.
k/o
5-1/2”
14-3/8”
19-5/16”
20-3/32”
TOP
BACK SIDE
1/2”
1/2”
10”
3-1/4”
10”
3-1/4”
C/L
Air Recirculating Louver Plate
ELECTRICAL
WARNING
$OO(OHFWULFDOZRUNPXVWE\SHUIRUPHGE\TXDOL¿HGHOHFWULFLDQRUSHUVRQZLWKVLPLODUWHFKQLFDONQRZ
how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use
extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/
ground. Please also refer Electrical Diagram labeled on product.
AK11xxx - 152 Watts @ 1.3 Amps
AK12xxBx - 70 Watts @ 0.8 Amps
Cable Lock:
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWV
and codes, purchase and install appropriate connector if necessary.
Installation – Preparing Electrical
Cable Lock
9
1. Remove filters
2. Remove cover from junction box to
gain access to electrical wiring.
3. If using a cable lock, pry open the
desired electrical knockout either on
top or back of hood. Feed the wires
through the cable lock. Some local
codes require the use of a cable lock,
check your local codes.
4. If using hood in air recirculating
mode skip steps 4 and 5.
Pry open desired 3-1/4” x 10” ducting
knock-out either on top or back of
hood.
5. Secure 3-1/4” x 10” starting collar
with damper to the duct opening using
(10) M4x8 screws.
Installation – Preparing Electrical and Ducting
10
www.zephyronline.com
An air recirculating kit (optional) must be
purchased before using hood in recirculat-
ing mode.
1. Secure each of the (2) spring clips to the
safety grille body (A). Do this by inserting
the screw through the spring and into the
clip. Secure each clip to the safety grille
body by using a philips head screwdriver.
2. Insert charcoal filter into charcoal filter
holder (B) and place it over the safety grille
body (A)
3. Secure charcoal filter holder to safety
grill body by lifting up on spring clips and
twisting. The clip should cover the lip of the
charcoal filter holder securely.
4. Remove each screw from recirculating
top plate. Plate is located on top of hood
towards the front.
NOTE: Skip the recirculating preparation pages if you are ducting the air out of your home.
Recirculating preparation
continued on next page
Installation – Converting to Air Recirculating Mode
Recirculating kit - 0AK11-21001
5HSODFHPHQW¿OWHU$.
11
7KHIROORZLQJLQVWUXFWLRQVDUHIRU%UHH]H,,DQG%UHH]H,KRRGVEHJLQQLQJZLWKVHULDOQXPEHUSUH¿[DQGODWHU
Installation – Converting to Air Recirculating Mode
12
www.zephyronline.com
5. Remove each of the 5 screws holding
the (2) interior recirculating panels.
6. Remove (2) interior recirculating panels.
7. Place louvered recirculating plate over
top opening and secure using the screws
previously removed.
NOTE: Skip this page if you are ducting the air out of your home.
Installation – Mounting the Range Hood
13
Hood is designed for installation under a kitchen
cabinet (Fig 1)
 6HOHFWSUHIHUUHGGXFWORFDWLRQYHUWLFDORUKRUL]RQWDOLI
ducting out of kitchen. Refer to page 7 for details.
 %HJLQLQVWDOODWLRQE\UHPRYLQJWKH¿OWHUVLILQVWDOOHG
DQGVLGHVSDFHUSDQHOV´PRGHOVRQO\)LJ
3. Reinforce cabinet with 1”x2” wood strips if additional
strengthening is required or if cabinets are framed.
4. Temporarily position the range hood in the desired
mounting location. Measure and mark the mounting
holes, duct and electrical locations with a pencil.
5. Drill/cut out the required openings for duct and
electrical access by following the dimensions on page
8; make sure the duct opening is large enough to apply
duct tape.
 )DVWHQKRRGRQWRFDELQHWZLWK0ZRRGVFUHZV
with washers provided.
7. Install electrical.
8. Install duct work and seal with duct tape.
 5HLQVWDOO¿OWHUVDQGVLGHVSDFHUSDQHOVLIDSSOLFDEOH
10. Power up hood and check for leaks around duct tape.
11. If recirculating the hood refer to page 11 and 12 for
details.
duct/silver
tape
Duct
opening
cutout
Add 1x2
wood strips
electrical
Fig 1
6KRZQDVYHUWLFDOGXFWLQJ
Push in on panel latch then pull panel down
Fig 2
14
www.zephyronline.com
Features & Controls – Controls & Features
This switch turns the blower on and o and controls the speed selection.
is o, is low speed, is medium speed and is high speed.
is o, is dim, II is bright.
Breeze I, AK11xx
Lights Off/Dim/Bright
Lights Off/Dim/Bright
Blower On/Off/Speed Selection
This button turns the motors on and o. It also shuts o power to the whole hood.
If the lights are on and this button is pushed, they will also turn o.
This button turns the lights on, o and also dims them. Press once to turn them on bright,
again for dim and one more time to shut them o.
This button will change the speed setting of the motors. By pushing it you will change the
speeds from high to medium to low.
This button will put the hood into delay o mode. When pushed, the hood will switch to the
lowest speed and the entire hood will shut down all functions after 5 minutes.
Breeze II, AK12xxBx
15
SURFACE MAINTENANCE:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
&OHDQSHULRGLFDOO\ZLWKZDUPVRDS\ZDWHUDQGFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWK$OZD\VUXELQWKH
direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
After cleaning use a non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and
JUDLQ$OZD\VVFUXEOLJKWO\ZLWKFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWKDQGEXIILQWKHGLUHFWLRQRIWKHVWDLQOHVV
steel grain.
Cleaning Black Stainless Steel
&OHDQSHULRGLFDOO\ZLWKZDUPVRDS\ZDWHUDQGFOHDQFRWWRQJFORWKRUPLFUR¿EHUFORWK7RUHPRYHKHDYLHU
grease build up use a liquid degreaser detergent.
Due to a built-in layer of protective anti-smudge coating, do not use stainless steel polish/cleaners to buff out
black stainless steel.
Aluminum Mesh Filters
7KHDOXPLQXPPHVK¿OWHUVDUHLQWHQGHGWRWUDSUHVLGXHDQGJUHDVHIURPFRRNLQJ$OWKRXJKWKH¿OWHUVVKRXOG
never need replacing, they are required to be cleaned every 30 days or more often depending on cooking
habits.
)LOWHUVPD\EHSODFHGLQGLVKZDVKHUDWORZKHDWRUVRDNHGLQKRWVRDS\ZDWHU'U\¿OWHUVDQGUHLQVWDOOEHIRUH
using hood.
Removing Aluminum Mesh Filters (Fig 3)
 3XVKLQRQ¿OWHUKDQGOHV
 3LYRWIURQWRI¿OWHUGRZQZDUG
 5HPRYH¿OWHUE\SXOOLQJDZD\IURPKRRG
Replacing Aluminum Mesh Filters
Hood Model: Part No. Qty. to Order.
AK1124x 50200013 2
AK1100x / AK1136x 50200012 2
AK1200Bx / AK1236Bx 50200012 2
Maintenance – Cleaning and Filter Removal
Fig 3
16
www.zephyronline.com
BREEZE I, AK11xx model ONLY
REPLACING LIGHT BULBS
CAUTION: Light bulb becomes extremely hot when turned on.
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.
Make sure all power is turned off and bulbs are not hot.
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls
out.
,IEXOEVDUHGLI¿FXOWWRWXUQGXHWRSURORQJHGXVH¿UPO\DWWDFKDJODVVVXFWLRQFXSDSSUR[LPDWHO\WKHGLDPHWHURI
the bulb or use a rubber/latex glove and turn counter clockwise.
Replacement bulbs are available at most hardware stores or from www.zephyronline.com
3XUFKDVHW\SH05*8:KDORJHQ
For Zephyr part numbers please turn to page 19 of the manual.
Maintenance – Lights
Bottom hood view
Troubleshooting
17
TROUBLESHOOTING PROCEDURES FOR BREEZE I AND BREEZE II
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The switch or control board wirings are
disconnected.
3. Make sure the wirings at the switch or control
board are connected properly.
4. The wires on control board or switch are loose. 4. Make sure the wires on the control board or
switch are connected properly.
5. The switch or control board is defective. 5. Change the switch or control board.
Light works, but
blower is not
turning.
1. The blower is defective, possible seized. 1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The control board or blower switch is defective. 4. Change the control board or blower switch.
The unit is
vibrating.
1. The blower is not secure in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Change the blower wheel.
3. The hood is not secured in place. 3. Check the installation of the hood.
The unit is
whistling.
7KH¿OWHULVQRWLQWKHFRUUHFWSRVLWLRQ $GMXVWWKH¿OWHUVXQWLOWKHZKLVWOLQJVWRSV
2. The duct pipe connections are not sealed or
connected properly.
2. Check the duct pipe connections to be sure all
connections are sealed properly.
The blower is
working, but the
lights are not.
1. Defective bulb. 1. Change the bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
3. The light bulb plug is disconnected. 3. Connect the light bulb plug.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within 24” and 32”
range.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
2. Close all the windows and doors to eliminate
WKHRXWVLGHZLQGÀRZ
3. Blockage in the duct opening or duct work. 3. Remove all the blocking from the duct work or
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
Mesh Filter is
vibrating.
0HVK¿OWHULVORRVH 1. Make sure the metal clips in the handle are
QRWVWXFN2UUHSODFHWKHPHVK¿OWHU
2. Filter sping clip is broken. 8QLQVWDOODQGUHLQVWDOO¿OWHUSXVKXSRQ¿OWHU
ODWFK5HSODFHPHVK¿OWHULIQHHGHG
18
www.zephyronline.com
Wiring Diagrams
RED
BLACK
THERMALLY PROTECTED
Fan: 65W
Lamp: 5W
Total: 70W @0.8A
Power consumption
Voltage:
Models :
AK1236Bx
120V 60Hz
AK1200Bx,
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Zephyr AK1200BB Hood User Manual

Catégorie
Hottes
Taper
Hood User Manual
Ce manuel convient également à

dans d''autres langues