Master TB118A Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire

Ce manuel convient également à

IMPORTANT: Read and understand this manual before
assembling, starting or servicing heater. Improper use
of heater can cause serious injury. Keep this manual for
future reference.
GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions
provided with this heater, can result in death, serious
bodily injury and property loss or damage from hazards

poisoning and/or electrical shock.
Only persons who can understand and follow the instruc-
tions should use or service this heater.
If you need assistance or heater information such as an in-
structions manual, labels, etc. contact the manufacturer.
Save this manual for future reference.
For more information, visit www.desatech.com
PROPANE TENT EVENT
FORCED AIR HEATER
OWNER’S MANUAL
MODELS TB116A, TB117A AND TB118A
125,000 BTU/HR
125
TENT
Event
by
www.desatech.com
120942-01E2
WARNING: If the information in this manual is not

property damage, personal injury or loss of life.
 -
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
 
 
phone in your building.
 

 
department.
Installation and service must be performed by a quali-

If you smell gas, turn off gas supply at tank.
-
gen) from the tent in which it is installed. Provisions for
adequate combustion and ventilation air must be pro-
vided. Provide at least 42 square inches of opening.
State of Massachusetts: The installation must be made

of Massachusetts.
TABLE OF CONTENTS
Safety .................................................................. 3
Ventilation ............................................................ 5
Product Identication ........................................... 6
Propane Supply ................................................... 6
Electrical Supply .................................................. 7
Unpacking............................................................ 7
Theory of Operation............................................. 8
Assembly ............................................................. 9
Installation ..........................................................11
Operation ........................................................... 12
Storage .............................................................. 13
Maintenance ...................................................... 13
Service............................................................... 13
Specications .................................................... 17
Troubleshooting ................................................. 18
Technical Service............................................... 19
Wiring Diagram .................................................. 20
Parts .................................................................. 22
Replacement Parts ............................................ 26
Accessory .......................................................... 26
Warranty ............................................................ 28
www.desatech.com
120942-01E 3
SAFETY
General
ANSI/NFPA 102
Standard for Grandstands, Folding and
telescopic Seating, Tents and Mem-
brane Structures
ANSI/NFPA 58
Standard for Storage and Handling of
Liquieed Petroleum Gas Latest Edition
ANSI Z223.1/NFPA 54
National Fuel Gas Code Latest Edition
ANSI/NFPA 70
National Electric Code Latest Edition
CSA C22.1 Canadian Electrical Code
Part 1
The primary purpose of construction heaters
is to provide temporary heating of buildings
under construction, alteration or repair.
Properly used, the heater provides safe eco-
nomical heating. Products of combustion are
vented into the area being heated.
We cannot foresee every use which may be
made of our heaters. 

about heater use.
Other standards govern the use of fuel gases
and heat producing products for specific
uses. Your local authorities can advise you
about these.
WARNING: When used with-
out adequate combustion and
ventilation air, heater may give

an odorless, poisonous gas.
Do not install heater until all necessary provi-
sions are made for combustion and ventilation
air. Consult the written instructions provided with
the heater for information concerning combus-
tion and ventilation air. In the absence of instruc-
tions, refer to the national fuel gas code, ANS
Z223.1, Section 5.3 or applicable local codes.
This heater is equipped with a an Oxygen
Depletion Sensing (ODS) safety shutoff
system designed to turn off the heater if not
enough fresh air is available.

depletion safety system!
If heater shuts off, do not relight until you
provide fresh air. If heater keeps shutting off,
have it serviced. Keep burner and control
compartment clean.
WARNING: This product
contains and/or generates
chemicals known to the State

birth defects or other reproduc-
tive harm.
WARNING: Fire, burn, inhala-

solid combustibles, such as
tables, chairs, building materi-
als, paper or cardboard, a safe
distance away from the heater
as recommended by the instruc-
tions. Never use the heater in
spaces which do or may contain
volatile or airborne combustibles
or products such as gasoline,
solvents, paint thinner, dust par-
ticles or unknown chemicals.
WARNING: Not for home or
recreational vehicle use.
The heater is designed and approved for use
as a tent heater in accordance with these
instructions. CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY IF YOU HAVE
QUESTIONS ABOUT APPLICATIONS.
The heater is designed for use as a construc-
tion heater and as a vent-free tent heater. The
heater is designed for use in the space being
heated. The heater uses the air from within
the space being heated for combustion and
ventilation.
Applicable Standards:
For USA applications
ANSI Z83.7 - 2000
Gas Fired Construction Heaters
CGA 2.14 - 2000
Gas Fired Construction Heaters
CSA 3.06 - 2006
Portable Gas Fired Unvented Tent Heaters
For Canadian applications
ANSI Z83.7 - 2000
Gas Fired Construction Heaters
CGA 2.14 - 2000
Gas Fired Construction Heaters
www.desatech.com
120942-01E4
SAFETY
Continued
Note: Fan will continue running if fuel supply
is exhausted or thermal switch opens.

poisoning may lead to death!
   Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness, and/or nausea.
If you have these signs, the heater may not
be working properly. Get fresh air at once!
Check for proper ventilation and have heater
serviced. Some people are more affected by
carbon monoxide than others. These include
pregnant women, people with heart or lung
disease or anemia, those under the inuence
of alcohol, and those at high altitudes.
Propane/LP Gas: Propane/LP gas is odorless.
An odor-making agent is added to propane/LP
gas. The odor helps you detect a propane/LP
gas leak. However, the odor added to propane/
LP gas can fade. Propane gas may be present
even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.
WARNING: Do not place
-
terial on or near the appliance.
WARNING: Due to high tem-
peratures, the appliance should

from furniture.
WARNING: Young children
should be carefully supervised
when they are in the same room
with the appliance.
  
adults should be alerted to the
hazard of high surface tempera-
ture and should stay away to avoid
burns or clothing ignition.

or guard removed for servicing
an appliance must be replaced
prior to operating the heater.
1. Install and use heater with care. Follow all
local ordinances and codes. In the absence
of local ordinances and codes, refer to
the Standard for Storage and Handling of
Liqueed Petroleum Gas, ANSI/NFPA 58,
the Natural Gas and Propane Installation
Code, CSA B149.1, and ANSI/NFPA 102
Standard for Grandstands, Folding and
telescopic Seating, Tents and Membrane
Structures. This instructs on the safe stor-
age and handling of propane/LP gases.
2. Use only the electrical voltage and fre-
quency specied on model plate. The
electrical connections and grounding of
the heater shall follow the National Electric
Code, ANSI/NFPA 70 or the Canadian
Electrical Code, Part 1, CSA C22.1.
3. Electrical Grounding Instructions - This
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged di-
rectly into a properly grounded three-prong
GFI receptacle or extension cord.
4. Use only the hose and factory preset
regulator provided with the heater.
5. Use only propane/LP gas set up for vapor
withdrawal.
6.
This is an unvented gas-red tent heater.
It uses air (oxygen) from the tent in which
it is installed. Provide adequate ventilation.
Before using heater, provide at least a 42 in
2
(271 cm
2
) opening of fresh, outside air.
7. For indoor and outdoor use.
8. Do not use heater in occupied dwellings
or in living or sleeping quarters.
9. Do not use heater in basement or below
ground level. Propane/LP gas is heavier
than air. If a leak occurs, propane/LP gas
will sink to the lowest possible level.
10. Keep appliance area clear and free from
combustible materials, gasoline, paint
thinner, and other ammable vapors and
liquids. Dust is combustible. Do not use
heater in areas with high dust content.
www.desatech.com
120942-01E 5
29. The heater must be installed so that the
location of the heater does not obstruct or
interfere with normal or emergency exits
and doors or walkways in the structure.
30. Only use lifting handles to pick up appli-
ance (see Figure 1, page 6). Do not use
plastic top hand holds for lifting.
VENTILATION
WARNING: Follow the mini-
mum fresh, outside air ventila-
tion requirements. If proper
fresh, outside air ventilation is

poisoning can occur. Provide
proper fresh, outside air ventila-
tion before running heater.
Provide a fresh air opening of at least 42 in
2
(271 cm
2
) opening of fresh, outside air.
Example: 3" high x 14" long = 42 in
2
. Provide
extra fresh air if more heaters are being used.

1. Determine volume of space to heat:
Length x Width x Height
50 feet x 30 feet x 15 feet = 22,500 ft
3
2. Determine desired temperature rise:
Desired temperature 65° - 25° outside
temperature = 40° rise
3.
Multiply volume x rise: 22,500 x 40 = 900,000
4.
To determine how many BTU’s are needed
multiply by 0.133
900,000 x 0.133 = 119,000 Btu
The heater thermostat will cycle on and off to
maintain the desired room temperature more
often if the BTU/hr is oversized for the space
being heated. The air inltration and leakage
of heated air through cracks, passageway
openings, etc., will adjust the required BTU’s
needed for the desired temperature.
Ventilation Air Requirements - National

1 inch
2
of opening per 3,000 BTU with
outside air
1 inch
2
of opening per 1,000 BTU with non-
outside air
Determine fresh air needed
Input Max. divided by 3,000
125,000 BTU/hr ÷ 3,000 = 41.66
Provide 42 inch
2
of opening to fresh, outside air
3" high x 14" long - 42 inches
2
11. Minimum heater clearances from com-
bustible materials: Outlet: 8 ft. (2.40 m),
Sides: 1 ft. (30 cm), Top: 3 ft. (0.91 m),
Rear: 1 ft. (30 cm)
12. Keep heater at least 6 ft. (1.83 m) from
propane/LP tank(s). Do not point heater
at propane/LP tank(s) within 20 ft. (6 m).
In Canada keep heater at least 10 ft. (3 m)
from propane/LP tank(s).
13. Keep propane/LP tank(s) below 100° F
(38˚ C).
14. The minimum surrounding air temperature
rating for this heater is -20º F (-29º C).
15. Check heater for damage before each
use. Do not use a damaged heater.
16. Check hose before each use of heater.
If highly worn or cut, replace with hose
specied by manufacturer before using
heater.
17. Locate heater on stable and level surface
if heater is hot or operating.
18. Never block air inlet (rear) or air outlet
(front) of heater.
19. Keep heater away from strong drafts, wind,
water spray, rain, or dripping water.
20. Keep children and animals away from
heater.
21. Never move, handle, or service a hot
or operating heater. Severe burns may
result. You must wait 15 minutes after
turning heater off.
22. To prevent injury, wear gloves when han-
dling heater.
23. Never attach duct work to heater.
24. Space heaters used in the vicinity of tarpau-
lins, canvas or similar enclosure materials
shall be located a safe distance from such
materials. These enclosure materials shall
be of a re retardant nature. These enclo-
sure materials shall be securely fastened to
prevent them from igniting or from upsetting
the space heater due to wind action.
25. Do not alter heater. Keep heater in its
original state.
26. Do not use heater if altered.
27. Turn off propane/LP supply to heater and
unplug when not in use.
28. Use only original replacement parts. This
heater must use design-specic parts.
Do not substitute or use generic parts.
Improper replacement parts could cause
serious or fatal injuries.
SAFETY
Continued
www.desatech.com
120942-01E6
Figure 1 - Tent Heater
Top
Power Cord
Hose and
Regulator
Assembly
Gas Inlet
Lifting
Handle
Thermostat
Knob
ON/OFF
Switches
Receptacle
PROPANE SUPPLY
PRODUCT IDENTIFICATION
1. The amount of propane gas in tank(s)
2. The temperature of tank(s)
The following chart shows the number of
100 lb. (45 kg) tanks needed to run this
heater.
Smaller tanks can be used for limited run
times but it is recommended to use larger
tanks for optimum performance.
Average Temperature Number Of Tanks
 
Above 20° F (-6.7° C) 2
20° F (-6.7° C) to 0° F (-18° C) 3
Below 0° F (-18° C) Use larger tank
Less gas is vaporized at lower temperatures.
You may need two or more 100 lb. (45 kg)
tanks or one larger tank in colder weather.
Your local propane gas dealer will help you
select the proper supply system. The mini-
mum surrounding air temperature rating for
each heater is -20° F (-29° C).
Propane/LP gas and propane tank(s) are to
be furnished by the user.
Use this heater only with a propane vapor
withdrawal supply system. See Chapter 5
of the Standard for Storage and Handling
of Liqueed Petroleum Gas, ANSI/NFPA 58
and the Natural Gas and Propane Installation
Code CSA B149.1. Your local library or re
department will have this booklet.
Keep propane/LP tank(s) at least 5 ft away
from the side of the tent.
The propane/LP tank(s) shall be protected
from vehicles and secured in accordance
with the Standard for Grandstands, Folding
and Telescopic Seating, Tents and Membrane
Structures NFPA 102 and the Standard for
Storage and Handling of Liquieed Petroleum
Gases ANSI/NFPA 58.
The amount of propane gas ready for use
from propane tanks varies. Two factors decide
this amount:
Hand Holds
for Pushing
www.desatech.com
120942-01E 7
ELECTRICAL SUPPLY
This heater requires an electrical supply to
be furnished by the user. The electrical outlet
should have the following ratings:
120 volts (+/- 10%), 60 Hertz, 15 Amps
Ground Fault Interrupter (GFI)
The heater uses the ground circuit to prove the
ame by sending a low voltage (40 mV DC)
signal back to the DSI control. If the ground
supply is not correctly wired or is missing, the
heater will not work.

Extension cords used to connect the heater
must be 3 prong, grounded type of proper
gauge. Extension cord requirements are as
follows:
Up to 100 feet (30 m), use 16 AWG rated
cord
101 to 200 feet (32 to 60 m), use 14 AWG
rated cord.
OPERATION WITH PORTABLE
GENERATOR
WARNING: Before operating
heater or any appliance from a
portable generator, verify that
generator has been properly con-
nected to earth ground. Improper
grounding or failure to ground
generator can result in electro-
cution if a ground fault occurs.

by generator manufacturer for
proper grounding procedures.
The operating voltage range of the heater is
108 to 132 Volts (120 Volts +/- 10%). Prior
to plugging heater into generator the output
voltage should be veried (if generator is
equipped with the automatic idle feature, the
output voltage should be measured with the
generator running at full speed). If the voltage
does not measure in this range the heater
should not be plugged into the generator.
UNPACKING
1. Remove all packing items applied to
heater for shipment. Keep plastic cover
caps (attached to inlet connector and
hose/regulator assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If
heater is damaged, promptly inform dealer
where you bought heater.
www.desatech.com
120942-01E8
Figure 2 - Cross Section Operational View
Clean
Heated
Air Out
(Front)
Combustion Chamber
Hose/Regulator
Assembly
Injector
Motor and
Blower
Assembly
Cool
Air In
(Back)
Power Cord
Fuel
DSI
Air for Fuel
System
Thermal Switch
Ignitor, Flame
Sensor and ODS
Burner
Air Pressure Switch
THEORY OF OPERATION
The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The
propane gas moves through the automatic control valve and out the injector.
The Air System: The motor turns the fan. The fan pulls air into and around the combustion
chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The direct spark ignitor (DSI) sends voltage to the spark ignitor. The
spark ignitor ignites the fuel and air mixture.
 There are 4 independent systems:
1. Flame Sensor: This system causes the heater to shut down if the ame goes out.
2. Thermal Switch: This system causes the heater to shut down if the heater gets too hot
(blocked openings).
3. Air Pressure Switch: The system will not allow the heater to start if there is not adequate
air ow.
4.  This system shuts down the heater if the oxygen level
drops below the specied level (18%).
ODS Operation: Burner porting "blows" out causing ame sensor to cool, shutting down heater.
www.desatech.com
120942-01E 9
ASSEMBLY
Figure 3 - Attaching Handles
Handle
Screw
Nut
Lock Washer
Figure 4 - Installing Casters
Nut
Flat Washer
Caster
ASSEMBLY ITEMS
Before assembling heater, make sure you have the items listed below.
Phillips head screwdriver
Wrench
Hardware packet
Handles (2), 3/4" Screws (4), 1/4-20 Nuts (4), 1/4 Flat washers (4), 1/4 Lock washers (4)
Casters (2), 3/8" Nut (2), 3/8 Lock washers (2), 3/8 Flat Washers (4)
Wheels (2), Cotter Pins (2)
Brackets (4), 1/2" black screws (8), 3/8" screws (8)
Note: Place metal parts on packaging during assembly to protect from scratches.

1. Remove casters, 3/8 at washers, 3/8
lock washers and 3/8 nuts from hardware
packet.
2. You may wish to remove side panel from
heater to make installing casters easier.
If so, see Top and Side Panel Removal
on page 14. Figure 4 shows side panel
removed for clarity.
3. Use a spacer to prop end of heater up
so holes in base can be accessed (the 2
wheels stacked on top of each other will
accomplish this).
4. Place a at washer onto threaded stem of
caster. Insert caster stem through hole in
cabinet base as shown in Figure 4.
5. Attach each caster to base with a at
washer, a lock washer and a nut as shown
in Figure 4.
Side Handles
1. Remove handles, 3/4" screws, 1/4-20
nuts, 1/4 at washers and 1/4 lock wash-
ers from hardware packet.
2. Attach each handle to side panels with 2
screws, 2 nuts, 2 at washers and 2 lock
washers. Insert screw from outside of
heater and through handle. From inside
of heater, attach a at washer, then a lock
washer then a nut as shown in Figure 3.
Flat Washer
Lock Washer
www.desatech.com
120942-01E10
Bracket
Top
Bracket
Screws
Figure 6 - Attaching Top
ASSEMBLY
Continued
Figure 5 - Installing Axle and Wheels
Heater
Front
Axle
Wheel
Cotter Pin

1. Locate wheels, washers, cotter pins and
axle in hardware packet.
2. Carefully slide axle through heater body
as shown in Figure 5.
3. Slide one wheel and washer onto axle.
Insert cotter pin into end of axle. See
Figure 5.
4. Repeat steps 2 and 3 for second wheel,
washer and cotter pin on other side of
heater.
3. Turn top over and carefully place over
heater, positioning brackets through slots
in heater front and rear panels.
4.
Attach brackets to heater with 3/8" screws.
Bracket
Slots
Washer
Top
1. Remove 4 brackets, (8) 1/2" black screws
and (8) 3/8" screws from hardware
packet.
2. Lay top upside down on a clean surface.
Attach 4 brackets to top with 1/2" black
screws.
www.desatech.com
120942-01E 11
INSTALLATION
2. Connect fuel gas connector fitting on
hose/regulator assembly to propane
tank(s) (see Figure 7). Turn counterclock-
wise into threads on tank valve. Tighten
rmly using wrench.
IMPORTANT: Tighten regulator with vent
pointing down. Pointing vent down pro-
tects regulator from weather damage.
3. Connect hose to inlet connector (see
Figure 8). Tighten rmly using a wrench.
IMPORTANT: Extra hose or piping may be
used if needed. Install extra hose or piping
between hose/regulator assembly and
propane tank. You must use the regulator
supplied with heater.
4. Open propane supply valve on propane
tank(s) slowly.
Note: If not opened slowly, excess ow
check valve on propane tank will stop gas
ow. If this happens, close propane supply
valve and open again slowly.
5. Check all connections for leaks. Correct
all leaks.
Figure 7 - Regulator With Vent Pointing
Down
Hose
Regulator
Vent
(pointing
down)
Fuel Gas
Connector
Supply Valve
Propane
Tank
Figure 8 - Hose and Inlet Connector
Hose
Inlet
Connector
WARNING: Review and un-
derstand the warnings in the
Safety section, page 2. They are
needed to safely operate this
heater. Follow all local codes or
in the absence of local codes,
with the Standard for Grand-
stands, Folding and Telescopic
Seating, Tents and Membrane
Structures NFPA 102 and the
Standard for Storage and Han-
dling of Liquieed Petroleum
Gases ANSI/NFPA 58.
WARNING: Test all gas piping
and connections for leaks after
installation or servicing. Never

leak. Apply a noncorrosive leak
-
able at local plumbing supply
stores). Bubbles forming show a

1. Provide propane supply system (see
Propane Supply, page 6).
www.desatech.com
120942-01E12
OPERATION

1. Press Switch 1 to ON.
2. Press Switch 2 to ON.
3. Adjust thermostat knob to desired
comfort level.
Note: Fan will stay on when burner cycles off.
FAN ONLY WITH NO HEAT
1. Turn gas supply off.
2. Press Switch 1 to OFF.
3. Press Switch 2 to ON.
4. Adjust thermostat knob to Fan Only
position.
TO STOP HEATER
1. Tightly close propane/LP supply valve on
propane tank(s).
2. Wait a few seconds. Heater will burn gas
left in supply hose.
3. Press on/off switches to the OFF position.
4. Unplug heater.
TO RESTART HEATER
1. Press on/off switches to the OFF position.
2. Reconnect extension cord.
3. Turn on gas supply valve.
4. Follow To Start Heater instructions, col-
umn 1.
Thermostat
Fan Cycle
ON
OFF
Switch 1
Fan
Continuous
ON
THERMOSTAT
CYCLE
LOW
Fan Only
HIGH
OFF
Switch 2
8
1
2
3
4
5
6
7
Thermostat Knob
Figure 9 - Control Panel
WARNING: Review and un-
derstand the warnings in the
Safety section, page 2. They are
needed to safely operate this
heater. Follow all local codes
when using this heater.
TO START HEATER
1. Follow all installation, ventilation and
safety information.
2. Connect regulator/hose assembly to gas
supply.
3. Check for leaks using a noncorrosive leak
detection uid. Bubbles forming indicate a
gas leak. Correct all leaks before attempt-
ing to operate heater.
4. Locate heater on a stable and level sur-
face. Make sure strong drafts do not blow
into front or rear of heater.
5. Plug power cord of heater into a three
prong, grounded extension cord. Exten-
sion cord must be at least 6 feet (1.83 m)
long, CSA listed and of proper size.

Up to 100 ft. (30 m) long, use 16 AWG
rated cord.
101 to 200 ft. (31 to 60 m) long, use 14
AWG rated cord.
6. Plug extension cord into a 120v/60 hz,
three hole, grounded GFI outlet.
7. Open gas supply valve slowly.
Note: If heater burner does not ignite,
turn gas supply off and open slowly. The
hose/regulator assembly is equipped with
an excess ow safety valve. An audible
"click" is heard when opened too fast.
8. Choose desired function:
THERMOSTAT OPERATION WITH HEAT
1. Press Switch 1 to ON.
2. Press Switch 2 to OFF.
3. Adjust thermostat knob to desired
comfort level.
Note: Fan will cycle on and off with burner.
www.desatech.com
120942-01E 13
STORAGE
2. Place plastic cover caps over brass ttings
on inlet connector and hose/regulator as-
sembly.
3. Store in dry, clean, and safe place.
4. When taking heater out of storage, always
check inside of heater. Insects and small
animals may place foreign objects in
heater. Keep inside of heater free from
combustible and foreign objects.


1. Store propane tank(s) in safe manner. See
Chapter 5 of Standard for Storage and
Handling of Liqueed Petroleum Gases,
ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
Follow all local codes. Always store pro-
pane tanks outdoors.
MAINTENANCE
WARNINGS
 
is plugged in, connected to
propane supply, operating, or
hot. Severe burns and electri-
cal shock can occur.
     
from combustible materials,

vapors and liquids.
 -
bustion or ventilation air.
1. Keep heater clean. Clean heater annually
or as needed to remove dust and debris.
If heater is dirty or dusty, clean heater
with a damp cloth. Use household clean-
ers on difcult spots. Slight odor may be
present for a brief period following use of
household cleaners.
2. Inspect heater before each use. Check
connections for leaks. Apply a noncor-
rosive leak detection uid to connections.
Bubbles forming show a leak. Correct all
leaks at once.
3. Inspect hose/regulator assembly before
each use. If hose is highly worn or cut,
replace with one specied by manufac-
turer.
4. Have heater inspected yearly by a quali-
ed service agency.
5. Keep inside of heater free from combus-
tible and foreign objects. Remove motor
and other internal parts if needed to clean
inside of heater (see Service, below).
Burner
Check burner air inlet after every 300 hours
of operation to ensure burner air inlet is free
of dust or debris. Use compressed air (30 PSI
or less) to clean out burner air inlet.
SERVICE
WARNING: Never service
heater while it is plugged in,
connected to propane supply,
operating, or hot. Severe burns
and electrical shock can occur.
IMPORTANT: CHECK FOR GAS LEAKS. Test
all gas piping and connections for leaks after
installation or servicing. Never use an open
ame to check for a leak. Apply a noncorrosive
leak detection uid to all joints (available at lo-
cal plumbing supply stores). Bubbles forming
show a leak. Correct all leaks at once.
www.desatech.com
120942-01E14
SERVICE
Continued


1. Remove top and side panel (see Top and
Side Panel Removal, above).
2. Locate wiring diagram on inside of side
panel or go to page 20.
3. Check that all wiring terminals are se-
curely connected.
4. Check for gas leaks around ttings and
tubing of plumbing connections. See
page 11.
MOTOR AND BLOWER ASSEMBLY
1. Remove top and side panel (see Top and
Side Panel Removal, above).
2. Follow wires from blower/motor and dis-
connect from terminal blocks. Pull wires
out and coil excess to prevent damage to
insulation.
TOP AND SIDE PANEL REMOVAL
1. Remove 8 screws securing top brackets
to body panels. Remove top and set aside
(see Figure 10).
Brackets
Located
Underneath
Figure 10 - Removing Top and Side Panel
Side
Panel
Top
Bracket
Screws
Side Panel
Screw
2. Remove 2 screws securing side panel
at top edge. Remove 3 screws at lower
outside edge (see Figure 10). Push down
and lift out side panel.
3. Carefully remove 9 screws securing
blower mounting panel (see Figure 11,
page 15). Slide bafe top up and care-
fully lift entire assembly out of heater.
Assembly is heavy. Removal may require
assistance.
4. Remove 4 nuts securing blower/motor to
mounting panel.
5. Attach new blower/motor to mounting
panel and reinstall in reverse order. Insert
blower mounting panel under lip of bafe
top. Use care when removing or installing
blower to mounting panel to avoid dam-
age to wiring. Reattach wiring referring to
Wiring Diagram on page 20.
www.desatech.com
120942-01E 15
Figure 11 - Removing Blower/Motor Assembly
Terminal
Blocks
Blower/Motor
Blower
Mounting
Panel
Bafe Top
Figure 12 - Back Panel and Screen
Figure 13 - Removing Burner
Burner
Solenoid Valve
Back Panel
Screen
BURNER, IGNITOR AND GAS

WARNING: Make sure heater
is disconnected from propane and
electrical supply. Heater could
ignite causing severe burns.
Remove top and side panel (see Top and Side
Panel Removal, see page 14).
Replacing Burner
1. Remove all visible screws from lower sec-
tion of back panel and screen (see Figure
12). Pull back panel out to gain access to
screen. Push screen up and over ange,
then slide out.
2. Disconnect orange ignitor wire from ignit-
or. Ignitor is attached to back of burner.
3. Disconnect gas line at solenoid valve
and at orice using a 5/8" wrench. Avoid
bending and set aside.
4. Remove 3 screws securing burner to
partition (see Figure 13). Rotate burner
clockwise and pull out of chamber.
Note: There is a cutout on the partition
that allows the ignitor and bracket to slide
out as a complete assembly. Use caution
when removing or installing burner to avoid
damaging or dislocating ignitor electrode.
5. After all service is complete, reinstall
burner in reverse order. Support burner
SERVICE
Continued
while inserting burner locator pin into hole
in chamber end panel. Replace screen
and back panel.
www.desatech.com
120942-01E16
Replacing Ignitor
1. To loosen back panel and gain access
to ignitor, follow step 1 under Replacing
Burner, page 15. Due to lack of working
area, burner assembly may be removed
to gain access to ignitor electrode, see
Replacing Burner, page 15.
2. Remove ignitor bracket screw and lift
ignitor.
3. Attach new ignitor with ignitor mounting
screw removed in step 2.
4. Install new ignitor. Ignitor gap between
ignitor electrode and burner deck is
0.10"/0.12" (2.5/3.0 mm).
5. With gas supply shut off, test for spark.
Plug into extension cord and watch for
spark between ignitor electrode and
burner deck.
SERVICE
Continued
Ignitor Gap
Figure 14 - Ignitor Gap

1. Hold burner flange and rotate orifice
counterclockwise to remove.
2. Install new orice
IMPORTANT: CHECK FOR GAS LEAKS. Test
all gas piping and connections for leaks after
installation or servicing. Never use an open
ame to check for a leak. Apply a noncorrosive
leak detection uid to all joints (available at lo-
cal plumbing supply stores). Bubbles forming
show a leak. Correct all leaks at once.

1. Remove top and side panel (see Top
Panel Removal, page 14).
2. Disconnect orange ignitor wire.
3. Remove white wire connector.
4. Remove 2 screws and nuts securing DSI
control.
5. Install new DSI control. Reconnect wiring.

1. Remove top and side panel (see Top and
Side Panel Removal, page 14).
2. Disconnect 2 blue wires.
3. Remove gas line.
4. Remove 2 screws and nuts holding valve
to mounting plate.
5. Remove brass ttings from old gas valve.
If damaged replace with new fittings.
Install ttings into new gas valve. Use
pipe joint sealant that is resistant to liquid
petroleum (LP) gas. Tighten all ttings.
6. Install new gas valve using screws and
nuts from step 4.
7. Connect blue wires to new gas valve.
8. Reconnect gas line.
IMPORTANT: CHECK FOR GAS LEAKS. Test
all gas piping and connections for leaks after
installation or servicing. Never use an open
ame to check for a leak. Apply a noncorrosive
leak detection uid to all joints (available at lo-
cal plumbing supply stores). Bubbles forming
show a leak. Correct all leaks at once.

PRESSURE
1. Remove top and side panel (see Top
Panel Removal, page 14).
2. Locate pressure tap on solenoid valve and
remove (retain plug for later installation).
See Figure 15, page 17.
3. Install 1/8 NPT barb tting with sealant on
threads into solenoid valve.
4. Connect to manometer or pressure gauge
that measures in inches of water.
5. Connect hose and regulator to heater and
tank.
6. Plug in and turn on.
www.desatech.com
120942-01E 17
SPECIFICATIONS
Output Rating - 125,000 Btu/Hr (131,882 kJ/Hr)
Fuel Consumption - 1.4 Gal/Hr (5.2 Liters/Hr), 5.8 lb/Hr (2.6 kg/Hr)
Propane Vapor Fuel Only
Manifold Pressure - 10" (25.4 cm) WC
Supply Pressure To Regulator: Minimum (for purposes of input adjustment) 10 psi (69 kPa),
Maximum - Tank Pressure
Regulator Outlet Pressure - 11" wc
Electric Input - 120 V/60 Hz
Amperage - Start 7, Run 3.5
Load - 10 amps on receptacle
Hot Air Output (Approx) - 1000 CFM (28.3 m
3
/min)
Motor - 1,100 RPM, 1/4 HP
Ignition - Electronic Direct Spark Ignition (D.S.I.)
Ignitor Gap - 0.10"/0.12" (2.5/3.0 mm)
Figure 15 - Tent Heater Parts
Solenoid
Valve
Receptacle
DSI
Terminal
Boards
Thermostat
Switches
Gas Line
Burner
Pressure
Switch
SERVICE
Continued
Vacuum
Pressure
Pressure
Tap
Thermal
Limit Switch
Injector
www.desatech.com
120942-01E18
REMEDY
1. Check voltage to electrical
outlet. If voltage is good,
check heater power cord for
breaks
2. Adjust thermostat to higher
setting
3. Wait for ambient temperature
to decrease
4. Replace motor. See Motor and
Blower Assembly, page 14
5. Check wiring for loose con-
nections or damage
1. Check gas supply, connec-
tions and hoses
2. Repeat installation and op-
eration instructions. See
Installation, page 11 and
Operation, page 12
3.
A) Check ignitor wire. Tighten
or reattach loose ignitor wire.
B) Assure gap between ignitor
electrode and burner deck is
0.10"/0.12" (2.5/3.0 mm). Do
not bend electrode. Doing so
may cause it to break
C) Replace ignitor elec-
trode. See Replacing Ig-
nitor, page 16
D) Replace spark trans-
former. See Replacing DSI
Control, page 16
3. Clean tubing

1. No electrical power to heater
2. Thermostat set too low
3. Ambient temperature is too
high. Thermostat is satis-
ed
4. Defective motor
5. Loose wiring connections
1. No fuel ow
2. User did not follow installa-
tion or operation instructions
properly
3. No spark at ignitor. To test
for spark, follow step 5 under
Replacing Ignitor, page 16. If
you see spark at ignitor, have
heater serviced by qualied
service person. If no spark
seen:
A) Loose or disconnected
ignitor wire
B) Wrong spark gap
C) Bad ignitor electrode
D) Bad spark DSI
3. Air proving switch blocked
OBSERVED FAULT
Fan does not turn when
switch(s) 1 or 2 are pressed
to ON
Heater will not ignite
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, connected
to propane supply, operating, or hot. Severe burns and electrical
shock can occur.
www.desatech.com
120942-01E 19
WARNING: Use only in areas
free of high dust content.
TROUBLESHOOTING
Continued
REMEDY
1. A) Rell tank
B) Provide additional and/or
larger tanks. See Propane
Supply, page 6
2. This can happen when running
heater in temperatures above
85° F (2 C). Run heater in
cooler temperatures
3. Check heater inlet and outlet.
Remove any obstructions
4.
Replace motor and blower as-
sembly. See page 13
5. Clean heater. See Mainte-
nance, page 13
1. Check all connections for
leaks. Apply noncorrosive leak
detection uid to gas joints.
Bubbles forming show a leak
that must be corrected
2. To obtain correct mixture of
propane/LP gas and air, use
a larger cylinder size, i.e.
100 lb. See Propane Supply,
page 6
3. Use a larger supply cylinder
size, i.e. 100 lb.

1. Propane supply may be
inadequate
2. High surrounding air tem-
perature causing thermal
limit device to shut down
heater
3. Restricted air ow
4. Damaged fan
5. Excessive dust or debris in
surrounding area
1. Gas leak
2. Heater operating on a 20 lb.
propane/LP cylinder. Insuf-
cient propane/LP gas will be
supplied by a 20 lb. cylinder
resulting in odor
3. Propane/LP supply tank is
"freezing up". Evaporation
and consumption rate of
propane/LP from supply tank
is to great for the size of the
tank and air temperature
OBSERVED FAULT
Heater shuts down while
running
Heater producing odor
TECHNICAL SERVICE
You may have further questions about installa-
tion, operation, or troubleshooting. If so, con-
tact DESA Heating, LLC at 1-866-672-6040.
When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA Heating, LLC’s web
site at www.desatech.com.
www.desatech.com
120942-01E20
WIRING DIAGRAM
Electrical Connection Diagram
Motor
Moteur
VAC
Switch
(4)
Thermostat
Te rmostato
Receptacle
(6)
Switch 1
Cycle
(1)
White
Blanco/Blanc
White
Blanco/Blanc
White
Blanco
Blanc
White
Blanco
Blanc
White/Blanco/Blanc
White
Blanco
Blanc
White/Blanco/Blanc
Solenoid Valve/
Válvula de solenoide/
Électrovanne
DSI
(encendedor
de chispa
directa)
AED
Black
Negro
Noir
Black
Negro
Noir
Black
Negro
Noir
Black
Negro
Noir
Black
Negro
Noir
Orange
Naranja
Black
Negro
Noir
Green
Verde
Vert
Green
Verde
Vert
Green
Verde
Vert
Green
Verde
Vert
Blue
Azul
Bleu
Blue/Azul/Bleu
Blue/Azul/Bleu
Red/Rojo/Rouge
Red
Rojo
Rouge
Red
Rojo
Rouge
Terminal Block
(3)
Terminal Block
(3)
Switch 2
Continuous
(2)
(1) Interruptor 1 ciclo automático/
Interrupteur 1 en cycle
(2) Interruptor 2 continuo/
Interrupteur 2 en continu
(3) Bloque de terminales/Bornier
(4) Interruptor de VCA/
Interrupteur V c.a.
(5) Interruptor térmico/
Interrupteur thermique
(6) Enchufe/Prise
Power Cord/
Cable de alimentación/
Cordon électrique
Thermal Switch
(5)
Motor
Moteur
White
Blanco/Blanc
White/Blanco/Blanc
S1 = Switch 1
(1)
S2 = Switch 2
(2)
VAC = VAC Switch
(4)
T/S = Thermal Switch
(5)
T = Thermostat
Neutral
Neutro
Neutre
White
Blanco
Blanc
Black
Negro/Noir
Black
Negro/Noir
Black
Negro/Noir
Black
Negro
Noir
Black
Negro
Noir
Blue
Azul
Bleu
Blue/Azul/Bleu
Blue/Azul/Bleu
T
L1
DSI
VAC
S2
Receptacle
(6)
S1
Solenoid
Valve
Ignitor
Encendedor
Allumeur
Orange
Naranja
T/S
L2
Red/Rojo
Rouge
Red
Rojo
Rouge
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Master TB118A Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues