Greenlee Communications PE930 Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur
PE930 • PE945 • PE961
Telephone Test Set
ADSL Compatible and 2-Way
Hands-free*
Microtelefono
de Prueba
Manos Libres y
Compatible con ADSL
Combiné d’essai
analogique
Mains-libres et
compatible LNPA (ADSL)
INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D’INSTRUCTIONS
Read and understand all of the instructions and safety information in this
manual before operating or servicing this tool.
Lea y entienda todas las instrucciones y la información sobre seguridad
que aparecen en este manual, antes de manejar estas herramientas o
darles mantenimiento.
Lire attentivement et bien comprendre toutes les instructions et les
informations sur la sécurité de ce manuel avant d’utiliser ou de procéder à
l’entretien de cet outil.
Register this product at www.greenlee.com / Registre este producto en www.greenlee.com
Enregistrez votre produit en ligne, www.greenlee.com
52031028 REV 3 © 2018 Greenlee Textron Inc. 02/18
1 2 3
4 5 6
7 8 9
0
#
English ........................... 2–14
Español......................... 15–27
Français ....................... 29–44
2
Description
The Nautilus Series PE9XX test sets are intended to troubleshoot communication circuits.
Its features include:
• Three Operating Modes: Talk (off-hook), Monitor (on-hook and listening), and Off
• ADSL Compatibility
• Two-way Hands-Free Speakerphone* (PE945 & PE961)
• Loudspeaker Listening
• Tone or Pulse Dialing
• Mute Function
• Luminescent Keypad
• Automatic Detection and Lockout of Digital Lines (PE961 only)
• Automatic Detection and Lockout of High Voltages (PE945 & PE961 only)
• Automatic Overcurrent Detection and Limitation
• Storage of up to Ten 21-digit Telephone Numbers
• Up to 31-digit LNR (Last Number Redial)
• Two-Tone Ringer with Adjustable Pitch
• Sealed Electronics
• Waterproof (IP67)
• Buoyant — Floats if Dropped in Water
• Chemical Resistant
Three Year Warranty
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction
manual and any markings on the tool provide information for avoiding hazards and unsafe practices
related to the use of this tool. Observe all of the safety information provided.
Purpose of this Manual
This manual is intended to familiarize personnel with the safe operation and maintenance procedures
for the Greenlee PE9XX Nautilus Series Telephone Test Sets.
Keep this manual available to all personnel.
Replacement manuals are available upon request at no charge at www.greenlee.com.
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
All specifications are nominal and may change as design improvements occur. Greenlee Textron Inc. shall not be liable
for damages resulting from misapplication or misuse of its products.
KEEP THIS MANUAL
PE930 • PE945 • PE961
3
Important Safety Information
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an
injury or property damage. The signal word, defined below, indicates the severity of the hazard.
The message after the signal word provides information for preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage.
Read and understand this material before operating or servicing this
equipment. Failure to understand how to safely operate this tool could result in
an accident causing serious injury or death.
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
4
Important Safety Information
When in Loudspeaker mode, keep the loudspeaker more than 1 foot (30 cm)
from your ear.
Misue could result in hearing damage.
Inspect the tester and cord for wear or damage. Replace worn, damaged or missing
components with Greenlee replacement parts. A damaged component may fail, resulting
in injury or property damage.
Do not perform any service or maintenance other than as instructed in this manual.
Failure to observe this precaution can result in injury or property damage.
Use this tool for the manufacturer’s intended purpose only. Use other than that which is described in
this manual can result in injury or property damage.
Replace weak or discharged batteries as soon as either of these conditions is detected.
PE930 • PE945 • PE961
5
Identification
LED Indications:
• Low Battery – middle LED flashes RED.
• Mute Mode – middle LED flashes GREEN.
• Off-Hook Mode – right LED flashes RED.
• Monitor Mode – right LED flashes GREEN.
Hazard Indications:
• A constant ringing may indicate a hazard–excessive AC voltage on the line. If you hear this
continuous rinng alarm, carefully remove the test set from the line.
Polarity LED
Mute and Low Battery
Mode LED
6
Specifications
Monitor Impedance .................................................................................................... > 400 kΩ @ 1 kHz
Loop Resistance (maximum) ............................................................................................................5 kΩ
Current Draw ............................................................................................................................ < 15 mA
DC Resistance
Talk Mode ............................................................................................................................< 300 Ω
Idle ..................................................................................................... > 10 MΩ (30 µA @ 300 VDC)
Monitor ................................................................................................ > 10 MΩ (30 µA @ 300 VDC)
Temperature
Operating .............................................................................................–34 to 60 °C (–29 to 140 °F)
Storage ................................................................................................–50 to 75 °C (–58 to 167 °F)
Battery ......................................................................................9 V alkaline (NEDA 1604A or IEC 6LR61)
Introduction
The PE9XX Series Nautilus Telephone Test Sets are an advanced, convenient, and easy-to-use
telephone line troubleshooting device. Equipped with a number of LEDs and alarms, it lets the user
know the operating mode and provides alerts for hazardous situations.
LEDs: Polarity
Low Battery
Talk/Monitor
Tones: Low Pitch
Middle Pitch
High Pitch
The LEDs and tones indicate various conditions and functions. They are shown throughout the manual
in italic type.
The PE945/PE961 produces two types of alarms to alert the user to potentially hazardous situations.
Excessive DC voltage is indicated by low pitch tones (Boop... Boop... Boop...).
AC line voltage is indicated by continuous ringing.
If you hear either of these alarms, which are repeated in bold italic type in this manual, remove the
test set from the line carefully and immediately.
PE930 • PE945 • PE961
7
Operation
The test set must have a good 9V battery installed in order to operate.
See “Changing the Battery or Cordset” in this manual.
1. Connect the red wire to the ring (negative) side of the circuit.
2. Connect the black wire to the tip (positive) side of the circuit.
3. Use the Talk, Monitor and Mute features as described in this section.
Automatic Ground Start
Some lines, especially PABX, require a momentary ground to draw a dial tone.
Connect the test set’s red and black wires to the telephone circuit as usual, and connect the green wire
to ground. Press the TALK button momentarily to check for dial tone.
The ground start is automatic, and the green wire can remain connected without affecting the call.
TALK
Press once to go off-hook (connect). Press MONITOR to go on-hook (disconnect).
Off-Hook Mode
LED: Flashing red (first press)
Tone: Middle Pitch–Middle Pitch
LED: Flashing red (additional presses)
Tone: High Pitch
On-Hook Mode
LED: Flashing green (first press)
Tone: Middle Pitch
LED: None (second press)
Tone: Low Pitch
Automatic Line Checks
The PE945/PE961 is designed to allow testing of POTS service on a live xDSL line with reduced risk of
bringing down the data service. At any attempt to go Off-Hook, the test set automatically performs the
following line checks:
1. Digital Signal Presence (PE961 only): A two-tone alarm (middle pitch – low pitch) sounds
and the test set locks out. To override this alarm, e.g. on an ADSL line, press the TALK key. Once
overridden, the alarm will remain cancelled until the unit is either turned off or disconnected from
the line.
2. High DC Level (76V-116V): A single-tone alarm (low pitch) sounds, the hook status LED flashes
red and green and the test set locks out. To override this alarm, press and hold the TALK key until
the alarm stops.
3. HIGH DC Level (>116V): A single-tone alarm sounds and the test set locks out. The alarm may not
be overridden.
The PE930 does not include these features.
8
Operation (cont’d)
MONITOR
Press once to monitor the line without disturbing data, signal, or voice transmissions on the line. Press
repeatedly to alternate between Monitor mode and off. If the test set is off-hook (connected), pressing
MONITOR will release the line (disconnect).
To conserve battery life, the test set will shut off after 20 minutes of monitoring or 5 minutes after
removal from the line.
Monitor Mode
LED: Flashing green
Tone: Middle Pitch
MUTE
Press and release to stop transmitting over the line, to filter outside noise from the line, or to eliminate
sidetones. Press again to talk. Mute works only when the test set is in Talk mode.
Mute Mode
LED: Flashing red
Tone: High Pitch (Mute ON)
Tone: Low Pitch (Mute OFF)
PE930 • PE945 • PE961
9
Dialing Features
PULSE
Pulse Dialing
Press PULSE, then press TALK.
The dialing mode will automatically return to tone-type dialing when the test set is removed from the
line or when the test set is switched off.
To mix pulse and tone dialing, select PULSE and dial the pulse digits. Then press
to select TONE
and dial the tone digits (the
will not be dialed).
Note: If the dialing string is started in Tone mode, it is not possible to add Pulse digits.
The Last Number Redial feature (explained later in this section) will dial this number as a mixture of
pulse and tone digits.
To dial this number from memory (explained later in this section):
• setting the dialing mode to Pulse before pressing MEM will dial the number as a mixture of pulse and
tone digits
• setting the dialing mode to Tone before pressing MEM will dial the number as tone digits only
LNR/PAUSE
Last Number Redial / Pause
Immediately after going off-hook, press LNR (last number redial) to redial the dialing string from the
previous call.
In STORE mode press PAUSE to insert a pause in a memory. If within the first 5 entries, this inserts a
2second pause in the dialing out string; if not, then it halts the dialing. Press PAUSE to resume.
STO
MEM
Store and Memory
Both the test sets can store up to 10 telephone numbers, one under
each of the digits (0–9).
To store a telephone number:
1. While connected to a line and in the Talk mode, press STO.
2. Press MEM and a location (0-9).
3. Enter the telephone number to be stored.
4. Press STO to store.
In addition to digits, the memory will also store
,
,
(flash) and
(pause).
To recall and dial a stored telephone number:
1. While connected to a line and in the Talk mode, press MEM.
2. Press the appropriate digit (0–9).
10
Other Features
FLASH
Flash
Press FLASH to generate a timed line break.
SPKR
Speaker
The PE930 allows loudspeaker listening only in talk mode and monitor mode.
The PE945/PE961 allows two different speaker modes: Loudspeaker (receive only) operation and
two-way hands-free operation.
• While off-hook, press SPKR. The test set is now in Loudspeaker mode, with the Mute feature
activated. The Mute LED will be flashing GREEN.
• From this mode, press MUTE to communicate in the two-way hands-free mode.
• When the test set is off, press SPKR to select Monitor mode with loudspeaker. Press again to select
Monitor mode without the loudspeaker.
WARNING! – When in Loudspeaker mode, keep the loudspeaker more than 1 foot (30cm) from your
ear. Misuse could result in hearing damage.
VOL
Volume Control
To control the speaker volume, press VOL. The speaker is set to automatically start out at the low
setting. Press VOL to toggle between high and low volume.
POL
Polarity
To determine the polarity, press POL. The LED will indicate polarity as follows:
Red wire connected to ring (negative)
LED: Steady green
Red wire connected to tip (positive)
LED: Steady red
Pressing POL while ringing will cause the LED to alternate between green and red.
PE930 • PE945 • PE961
11
Changing the Battery or Cord Set
Note: Replace the battery in less than one minute to retain the contents of the memory.
1. Disconnect the unit from the circuit.
2. Press MONITOR to go to off mode.
3. Loosen the three screws and the cover.
4. Replace the battery or cord set, as shown. Observe polarity. (Red/Black, +/–)
5. Replace the cover and tighten the screws.
Note: Skipping Steps 1 and 2 may cause the unit to malfunction. If the test set does not restart after
changing the battery, disconnect the battery for two minutes. Then proceed with Step 4.
A Positive or Tip (Black)
B Negative or Ring (Red)
C Earth Ground (Green)
Cleaning Instructions
Periodically wipe the case with a damp cloth and mild detergent.
*Green wire shown in diagram is part of the optional PE901 Ground Start Kit.
+
Black Wire Red WireGreen Wire*
*
12
Using the Test Set for Troubleshooting Circuits
Some general troubleshooting procedures and tips are provided here. These procedures may require
other tools or equipment that are specific to the communications system installation trade. For a
complete selection of VDV (voice-data-video) tools, please refer to a Greenlee full-line catalog or visit
our website at www.greenlee.com.
Ground fault Check for the presence of voltage. If voltage is
present, measure the level. If it is typical line
voltage, contact the local electric utility.
A long run of telephone
cable near a power line
Contact the local electric utility.
Power hum Cable imbalance Break the circuit down into sections and check each
section for an imbalance.
Momentary or impulse
noise
This may be due to an unbalanced cable, nearby
power switch gear, or similar equipment.
Popping, crackling The customer has an older carbon transmitter type
of telephone.
Noise Hiss (white noise);
pulse dialing causes a
momentary change in the
sound of the noise
This is probably due to water in the cables.
Cross connection Direct wiring fault Check for crossed pairs.
Cross-talk Split pair A split pair (a circuit made up of wires from two
separate wire pairs) will be unbalanced and prone
to cross-talk.
Symptom*
Possible Cause /
Troubleshooting Step
Explanation
This is a potentially hazardous situation!
If the test set produces the excessive DC voltage
alarm (low pitch, low pitch, low pitch) or the AC
line voltage alarm (constant ringing), remove the
test set from the line carefully and immediately!
Test set alarms Telephone wire
contacting a power line
* Wet cables may cause most of these symptoms and may cause multiple symptoms to appear at
the same time.
PE930 • PE945 • PE961
13
Troubleshooting (cont’d)
* Wet cables may cause most of these symptoms and may cause multiple symptoms to appear at
the same time.
Intermittent or
variable current
Wet cables or a
bad connection
If accompanied by noise, the cause is usually
wet cables.
If no noise is present, the cause is probably a bad
connection in a cross-connect or a bad connection
at the central office.
RFI (radio frequency
interference)
Split pair An unbalanced pair near a radio transmitter will
be prone to RFI. Adding radio filters can reduce the
interference on the line (the symptom), but does not
solve the imbalance (the problem). To troubleshoot,
break the circuit down into sections and check each
section for split pairs or a resistive imbalance.
A strong amount of radio interference may trigger
the test set’s excessive DC voltage alarm and
prevent connection when you attempt to go off-
hook. If this happens, listen closely for the sound of
a radio broadcast to determine if this is the cause
of the alarm. If it is necessary to make a call in
this situation, you may safely override the alarm by
holding down the TALK button for the duration of the
override tone. When the test set goes quiet, release
the TALK button and dial the number.
Note: This override procedure will not work if
the line is unpowered or if a hazardous DC voltage
is present.
Improperly removed bridge taps may also introduce
RFI. Bridge taps, which were once used for party-
line service (multiple users sharing a cable pair),
were often disconnected but left in place, with
a stub section of cable still connected. This stub
section can act as an antenna and induce radio
signals into the circuit.
Symptom*
Possible Cause /
Troubleshooting Step
Explanation
14
Dead circuit Open circuit or
short circuit
Break the circuit down into sections and check each
section for continuity.
(2b) When using the test
set in Monitor mode,
or with the test set
disconnected, the
voltage will be lower
than normal.
(2b) This indicates a partial short circuit.
(2a) When using the test
set in Monitor mode,
or with the test set
disconnected, the
voltage will
be normal.
(2a) This indicates a high-resistance fault, which
restricts the amount of current flowing through
the circuit. Possible faults include a poor con-
nection, wet cables, or a line extender failure.
Distortion, dialing
difficulty
(1) When using the test
set in Talk mode, the
voltage will be lower
than normal.
Symptom*
Possible Cause /
Troubleshooting Step
Explanation
* Wet cables may cause most of these symptoms and may cause multiple symptoms to appear at
the same time.
Troubleshooting (cont’d)
PE930 • PE945 • PE961
15
Descripción
El equipo de prueba PE945/PE961 es para diagnosticar circuitos de comunicación.
Sus características incluyen:
• Tres modos de operación: Conversación (Descolgado), Monitor (Colgado y escuchando), y
Desactivado
Compatibilidad con ADSL
• Altavoz manos libres bidireccional* (PE945 & PE961)
• Capacidad para escuchar con altavoz
• Marcación por tono o pulsación
• Función de silenciamiento
• Teclado luminosos
• Detección y bloqueo automático de líneas digitales (solo PE961)
• Detección y bloqueo automático de altas tensiones (solo PE945 y PE961)
• Detección y limitación automática de exceso de corriente
• Almacenamiento hasta de 10 números telefónicos con 21 dígitos
• Timbre de dos tonos ajustables
• Electrónicos sellados
• Impermeable (IP67)
• Flotante — Flota si cae al agua
• Resistente a los productos químicos
• Garantía de tres años
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las herramientas y equipo
Greenlee. Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la
información necesaria para evitar riesgos y hábitos poco seguros relacionados con su uso. Siga toda la
información sobre seguridad que se proporciona.
Propósito de este manual
Este manual tiene por objeto familiarizar al personal con los procedimientos de funcionamiento y
mantenimiento seguros para la serie Greenlee PE9XX Nautilus.
Manténgalo siempre al alcance de todo el personal.
Puede obtener copias adicionales de manera gratuita, previa solicitud en www.greenlee.com.
¡No deseche ni descarte este producto!
Para información sobre reciclaje, visite www.greenlee.com.
Todas las especificaciones son nominales y pueden cambiar conforme tengan lugar mejoras de diseño. Greenlee
Textron Inc. no se hace responsable de los daños que puedan surgir de la mala aplicación o mal uso de sus productos.
CONSERVE ESTE MANUAL
16
SÍMBOLO DE ALERTA
SOBRE SEGURIDAD
Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría ocasionar
lesiones o daños materiales. Cada uno de los siguientes términos denota la gravedad del riesgo.
El mensaje que sigue a dichos términos le indica cómo puede evitar o prevenir ese riesgo.
Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso la muerte.
Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la muerte.
Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o daños
materiales.
Lea y entienda este documento antes de manejar esta herramienta o darle
mantenimiento. Utilizarla sin comprender cómo manejarla de manera segura
podría ocasionar un accidente, y como resultado de éste, graves lesiones o
incluso la muerte.
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar graves lesiones o incluso la
muerte.
Importante Información sobre Seguridad
PE930 • PE945 • PE961
17
Importante Información sobre Seguridad
Cuando lo tenga en modo de altavoz, mantenga el altavoz a más de 1 pie
(30cm) de distancia del oído.
El mal uso puede ocasionar la pérdida auditiva.
Inspeccione el desgaste o daños en el probador. Cambie los componentes desgastados, dañados
o faltantes con piezas Greenlee. Los componentes dañados pueden fallar, lo cual puede ocasionar
lesiones o daños a la propiedad.
No le haga ningún servicio ni mantenimiento distinto al que se menciona en este manual.
No observar esta precaución puede ocasionar lesiones graves o la muerte.
Utilice esta herramienta únicamente para el fin estipulado por el fabricante. El uso para cualquier fin
distinto al que se menciona en este manual puede ocasionar lesiones y daños a la propiedad.
Cambie las pilas gastadas o descargadas apenas detecte cualquiera de esas condiciones.
18
Identificación
Indicaciones de los diodos fotoemisores:
• Pila descargada – Destello del diodo fotoemisor ROJO del MEDIO
• Modo Mudo – Destello del diodo fotoemisor VERDE del MEDIO.
• Modo Desenganchado – Destello del diodo fotoemisor ROJO de la DERECHA.
• Modo Monitor – Destello del diodo fotoemisor VERDE de la derecha.
Indicaciones de peligro:
• Un timbre constante puede indicar una tensión de CA excesiva y peligrosa en la línea. Si escucha
este alarma de timbre continuo, retire el equipo de prueba de la línea con cuidado.
TALK (HABLAR)
MONITOR (MONITOREAR)
MUTE (SILENCIADOR)
LED indicador de polaridad
Mudo y Pila descargada
LED indicador de modo
PE930 • PE945 • PE961
19
Especificaciones
Impedancia del Monitor .............................................................................................> 400 kΩ @ 1 kHz
Resistencia de Bucle (máxima) ........................................................................................................5 kΩ
Consumo de Corriente .............................................................................................................. < 15 mA
Resistencia de CC
Modo de Conversación ........................................................................................................< 300 Ω
En espera ........................................................................................... > 10 MΩ (30 mA @ 300 VCC)
Monitor ............................................................................................... > 10 MΩ (30 mA @ 300 VDC)
Temperatura
Funcionamiento .......................................................................................-34 a 60 °C (-29 a 140 °F)
Almacenamiento.....................................................................................-50 to 75 °C (-58 a 167 °F)
Pila ............................................................................................9 V alkaline (NEDA 1604A o IEC 6LR61)
Prefacio
Los equipos de teléfono Nautilus serie PE9XX son dispositivos avanzados para diagnosticar líneas
telefónicas, convenientes y fáciles de usar. Vienen equipados con un número de diodos fotoemisores
y alarmas, permiten que el usuario vea el modo de funcionamiento y emiten alertas en situaciones
peligrosas.
Diodos Fotoemisores: Polaridad
Pila descargada
Conversación/Monitor
Tonos: Tono Bajo
Tono Medio
Tono Alto
Los diodos fotoemisores y los tonos indican varias condiciones y funciones. Aparecen en cursiva a lo
largo de este manual.
El PE945/PE961 produce dos tipos de alarmas para alertar al usuario sobre situaciones potencialmente
peligrosas.
La tensión de CC excesiva se indica con tonos bajos seguidos.
El voltaje de CC de la línea se indica con un timbre continuo.
Si escucha cualquiera de esas alarmas, las cuales se repiten en cursiva negrita en este manual, retire
el equipo de prueba de la línea cuidadosa e inmediatamente.
20
Funcionamiento
El equipo de prueba debe tener instalada una pila de 9V para que funcione.
Ver “Cambio de Pila y Cable” en este manual.
1. Conecte el cable rojo al lado del timbre (negativo) del circuito.
2. Conecte el cable negro al lado de la punta (positivo) del circuito.
3. Utilice las características de Conversación, Monitorear y Silenciamiento descritas en esta sección.
Inicio Automático con Masa
Algunas líneas, especialmente centralitas (PABX), requieren una masa momentánea para obtener el
tono de marcación.
Conecte los cables rojo y negro al circuito del teléfono como de costumbre y el cable verde a tierra.
Apriete el botón TALK momentáneamente para comprobar el tono.
El inicio de masa es automático y el cable verde puede permanecer conectado sin que afecte la
llamada.
TALK (HABLAR)
Apriete una vez para conectar (descolgar). Apriete MONITOR para colgar (desconectar ).
Modo Desenganchado
DIODO FOTOEMISOR: Destello rojo (primer apriete)
Tono: Tono Medio–Tono Medio
DIODO FOTOEMISOR: Destello rojo (aprietes adicionales)
Tono: Tono Alto
Modo Enganchado
DIODO FOTOEMISOR: Destello verde (primer apriete)
Tono: Tono Medio
DIODO FOTOEMISOR: Ninguno (Segundo apriete)
Tono: Tono Bajo
Examen Automático de la Línea
El PE945/PE961 está diseñado para permitir la prueba del servicio telefónico en una línea ADSL activa
sin temor de interrupción del servicio de datos. El microtelefono hace las siguientes pruebas en la línea
automáticamente, ante cualquier intento de Desenganche:
1. Presencia de Señal Digital (Solo el PE961): Suena una alarma de dos tonos (medio – bajo) y el
equipo de prueba se aísla. Para anular esa alarma por ejemplo, en una línea ADSL, apriete el botón
TALK. Cuando esté anulada, la alarma permanece cancelada hasta que apague la unidad o hasta
que la desconecte de la línea.
2. Alto Nivel de CC (76V-116V): Suena una alarma unitonal (tono bajo), el diodo fotoemisor del
estatus del enganche-desenganche destella rojo y verde y el microtelefono se aísla. Para anular
esa alarma, apriete y sostenga el botón TALK hasta que la alarma pare.
3. ALTO Nivel de CC (>116V): Suena una alarma unitonal y el microtelefono se aísla. No se puede
anular la alarma.
PE930 no incluye estas característas.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Greenlee Communications PE930 Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur