Focal Solo6 Be Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur

Ce manuel convient également à

Twin6 Be Solo6 Be
Sub6
SOLO6 BE - TWIN6 BE - SUB6
Professional Analog Monitoring System
User manual / Manuel d'utilisation
English page 2
Français page 13
An example of this equipment has been tested and found to comply with the following European directives
and international standards:
Electromagnetic compatibility
EN 55103
EN 61000
Electrical safety
EN 60065
Important safety information
Please read carefully the following instructions and safety information. Heed all warnings and follow all instructions.
Do not remove the back panel. There are no user serviceable parts inside; please refer to qualified service personnel.
This equipment must be earthed.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where
they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
Servicing is required when the unit has been damaged in any way, such as power cord or plug is damaged, liquid has been
spilled or objects have fallen into the unit, the unit has been exposed to rain or moisture, does not operate normally, or has
been dropped.
• Do not place naked flame sources, such as lighted candles, on the apparatus.
• Use the apparatus only in moderate climates (not in tropical climates).
• Do not expose the apparatus to dripping or splashing.
• Do not place objects filled with liquids, such as vases, on the apparatus.
CAUTION!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
The Solo6 Be and Twin6 Be use a tweeter equipped with a Beryllium dome, allowing a frequency range extending beyond
40kHz. In its solid form, Beryllium is harmless. However, due to its nature, certain special precautions should be observed
to avoid exposure to unnecessary risk:
Under no circumstances should the Beryllium dome be subjected to any form of abrasive action. To ensure no accidental
damage to the tweeter dome it is advised to carefully replace the protection covers while not in use.
In the unlikely case of damage to the dome, of any form, a wide piece of adhesive tape should be immediately used to seal
the whole front surface of the tweeter. The protective cover should then be replaced and also taped securely in place. You
should then inform the dealer from whom you purchased the product so that the tweeter can be removed by a professional
and returned to the product distributor for replacement.
If the dome is broken in any way giving rise to loose particles of Beryllium, these should be carefully collected with the use
of an adhesive tape and sealed in a zip-top bag to be returned with the tweeter.
For further information, please contact Focal-JMlab directly: [email protected]om
SOLO6 BE - TWIN6 BE - SUB6
Professional Analog Monitoring System - User manual
2
Thank you for choosing the FOCAL Solo6 Be - Sub 6 - and/or Twin6 Be. The Solo6, Twin6 Be, and the Sub6 are world class
Professional Monitoring Systems. They have been designed to offer superior imaging, outstanding precision and extended
frequency range, in a compact format suitable for near field monitoring.
Unpacking
In addition to one loudspeaker and a user manual (such as this one), each Solo6 or Twin6 carton should contain:
• A power cord.
• A guarantee card.
• A protection grille for the Beryllium tweeter (you are advised to remove it before listening to the speakers).
A plastic bag containing an information note “Beryllium inverted dome tweeter”, and some adhesive tape to affix on the
tweeter in the unlikely event of the dome being damaged.
In addition to one subwoofer and a user manual each Sub6 carton include:
• A power cord.
• A guarantee card.
• A grille protecting the drive unit (which it is advisable to remove whenever possible).
Please check that none of these items are missing, and remove all accessories from the carton.
To remove the loudspeaker from its carton without damage, open the end flaps fully and bend them right back. Then remove
the upper cushion and lift the loudspeaker out gently. Inspect the speaker for signs of any possible damage.In the unlikely
event of this having occurred please inform the carrier and supplier. It is a good practice to keep the packaging in case of
future transportation.
Preliminary recommendations
We would like to give a word of warning about the high sound pressure levels that can be generated by these loudspeakers,
especially in a 5.1 configuration. Because of their low levels of distortion, and the minimal fatigue incurred by the user, it is
not always obvious to realise the actual sound pressure level while working.
Please bear in mind that exposure to excessive levels over a sustained period of time may lead to permanent hearing loss.
Warranty
These products are guaranteed against defects in components and workmanship only, for a period of two years from the date
of shipment to the end user for countries of the European Union. For other countries, please refer to the law in effect.
During the warranty period Focal will, at their discretion, either repair or replace products which prove to be defective,
provided that the product is returned, shipping prepaid, to an authorised Focal service facility.
Defects caused by unauthorised modifications, accident, negligence or any misuse are not covered by this warranty.
For further information please contact your dealer or the distributor in your country.
SOLO6 BE - TWIN6 BE - SUB6 - INTRODUCTION
Professional Analog Monitoring System - User manual
3
SOLO6 BE - TWIN6 BE - SUB6
Professional Analog Monitoring System - User manual
4
Input
sensitivity switch
D
B
Midrange
Midrange
E
A
Audio
input connector
Voltage selector
Fuse holder
HF control
LF control
Audio
input connector
Input sensitivity
Switch
Midrange driver
selector
Voltage selector
Fuse holder
HF control
LF control
Position A
Lelf/Right
Position B
Lelf/Right
Position C
Left
Position C
Right
Position A
Lelf/Right
Position B
Lelft
Position C
Left
Right
Driver choosen to reproduce midrange when switch selected for left speaker
Driver choosen to reproduce midrange when switch selected for right speaker
Lelf/Right
Right
F
C
Recommended choice for
midrange driver positionning.
Midrange driver on the inside.
Hi Pass switch
Defeat switch
Phase control
Level control
Lo Pass control
Polarity switch
Mute switch
Voltage selector
Audio intput connectors
(Stereo/2.1 wiring only)
Audio output connectors
to satellites speakers
(Stereo/2.1 wiring only)
LFE input connector
(mutichannel
wiring only)
G
6.35 Jack connector
for 2.1 Bypass
footswitch
remote control
SOLO6 BE - TWIN6 BE - SUB6
Professional Analog Monitoring System - User manual
5
Solo6 Be
The Solo6 Be is a two-way active loudspeaker (2 internal amplifiers channels), comprising one “W” cone 6.5” low/mid unit,
loaded with a large cross-section laminar port, and an inverted pure Beryllium dome (fig. A).
Twin6 Be
The Twin6 Be is a three-way active loudspeaker (3 internal amplifiers channels), comprising two “W” cone 6.5” low/mid units,
loaded with two large cross-section laminar ports, and an inverted pure Beryllium dome. The two 6.5” drive units operate at
low frequencies but only one of them (either can be selected) will reproduce the midrange (fig. B).
Sub6
The Sub6 is an active subwoofer (1 integral amplifier) designed for professional monitoring systems. It uses a 11” drive unit
equipped with a “W” composite cone, and loaded by a large cross-section laminar port (fig. G).
The Sub6 may be used :
- For bass or sub-bass enhancement in stereo + sub setups (2.1 or 2.2). The rear panel of the Sub6 allows for the connection
of a traditional stereo source (Left In / Right In), while providing hi-passed outputs intended to feed the main speakers
(satellites),
- As a LFE channel (Low Frequency Effects) in a multi-channel installation (5.1, 5.2, 6.1…), via a dedicated input of the
rear panel.
Installing
Mains voltage
After having unpacked the unit, first check that the operating voltage is correctly set (see location on rear panel). If it is not,
adjust the selector to the appropriate position. Also check and if necessary replace the fuse, which rating depends on the
operating voltage (please refer to technical specifications).
The Solo6 and Twin6 must be earthed using the power cord supplied.
Audio connections: general
The audio signal is to connect to the XLR inlet. This is a balanced input, which use the standard cabling scheme, namely:
Pin 1 = Ground (shield)
Pin 2 = In phase voltage (“hot”)
Pin 3 = Out-of-phase voltage (“cold”)
If the audio source is unbalanced, common practice is to link “cold” and ground pins (pins 3 and 1 respectively).
This is generally achieved within the cable.
Audio connections: Sub6 (fig. G)
Stereo + Sub setup (2.1 or 2.2):
Left IN: this input is intented to receive the signal coming from the left channel of your source (mixing console, or other…).
Right IN: this input is intented to receive the signal coming from the right channel of your source (mixing console, or other…).
Left OUT: this output is intended to connect to the left main loudspeaker of your system. The signal supplied by this output
is internally processed through a high pass filter.
Right OUT: this output is intended to connect to the right main loudspeaker of your system. The signal supplied by this
output is internally processed through a high pass filter.
Multichannel configuration:
LFE: this input is intended to feed your Sub6 in a multichannel application (5.1, 5.2, 6.1, …): this channel is dedicated to low
frequencies only.
SOLO6 BE - TWIN6 BE - SUB6: PRODUCT OVERVIEW
Professional Analog Monitoring System - User manual
6
Positioning
The Solo6 Be and Twin6 Be are designed for near field monitoring and should be placed at a distance between 1 and 3 metres
from the listener, pointing towards the listening position. They can be sitting on the console top or placed on appropriate
stands. In any way it is recommended that the tweeter is at a height from the floor approximately equivalent to that of the
listener’s ears. If required it can make sense to place the speakers upside down so that the previous rule is better fulfilled
(fig. C,D).
The Solo6 Be could be used vertically or horizontally depending on the environment, preferably pointing towards the listener
(fig. C).
By design the Twin6 Be’s are rather intended for a landcape orientation, though in some situations they could be positioned
vertically. As seen in the earlier rear panel description, the Twin6 Be has a switch allowing to choose which drive unit is to
reproduce the mid frequencies (see below) (fig. E). Consequently it will always be possible, as desirable, to configure the
speakers in a “mirror” (ie symetrical) way (fig. F). As a general rule having the “midrange” driver on the inside of the cabinet
results in better imaging.
Optimal positioning of the Sub6 may vary depending on the surface, the shape and acoustic properties of the listening room.
You are advised to try various locations so to choose the one giving the best possible and most level sound balance. As a rule
of thumb the optimal location will often be in a corner of the room.
SOLO6 BE - TWIN6 BE - SUB6: PRODUCT OVERVIEW
Professional Analog Monitoring System - User manual
7
Running in
As in all brand new loudspeaker the drivers need some run in period: they are mechanical elements demanding a little time
to settle and adapt to the climatic environment. This period will vary depending of the working conditions and may take up
to a few weeks. Avoid pushing the speakers very hard during their first hours of use, but to accelerate the run-in process
it is good practice to operate the speakers at moderate levels for 20 hours or so, with programmes having significant low
frequency content. Only once the transducers have come to stabilize will you get the optimum performance.
Solo6 Be/Twin6 Be/Sub6 Controls
Speaker switch (Left/Right) : only for Twin6 Be
This switch allows the user to select which one of the two 6.5” drivers will reproduce the midrange. By convention, the
“Right” position of the switch will select the left hand side driver (when facing the cabinet laying horizontally). Conversely in
the “Left” position the right hand side driver (facing the cabinet) will be the one operating in the mid frequencies. It is easy
to figure how useful this control is when it comes to get the best possible imaging in any cabinet layout (fig. E,F).
Input switch
The input sensitivity can be adjusted using this two position switch. The +4dBu position is suitable for standard professional
audio equipment, while -10dBV position may be used for other types of sources providing a lesser output level.
HF contour
This control allows for a continuous adjustement of the high frequency level; it operates above 5kHz within a ±3dB range
(fig. H).
LF contour
This control allows for a continuous adjustement of the low frequency level; it operates below 150Hz within a ±6dB range (fig. I).
This adjustement is typically useful to deal with possible excessive level of LF energy resulting from acoustic coupling
associated with close reflecting surfaces: mixing console, nearby walls…
Power on indicator
A power on LED is located on the cabinet front panel, near the Focal logo.
H
I
SOLO6 BE - TWIN6 BE - SUB6: : USING THE SYSTEM
Professional Analog Monitoring System - User manual
8
Sub6 controls (fig. G)
Level
This adjustement allows to set the sound level of the subwoofer relative to that of the main loudspeakers. It should also be
optimised taking into account the actual location of the subwoofer and its acoustic consequences: for example in an angle
the 6 dB acoustic gain should be compensated by an equivalent attenuation to maintain the overall balance of the system.
Mute
This switch will turn out the output signal of the subwoofer channel (making it silent does not require to switch the power off).
When muting the subwoofer the high pass filters used for the main speakers will remain active.
Hi Pass
This area is dedicated to the setting of the high pass filters intended for the main speakers in a 2.1 configuration. The “Defeat”
switch allows to disable (ie by-pass) these filters. The 75 Hz / 100 Hz switch allows to select the cut-off frequency, in order to
optimise the acoustic recombination between the satellites and the Sub6.
Lo Pass
This potentiometer adjusts the cut-off frequency of the low pass filter on the subwoofer channel, thus setting the upper
frequency range to be reproduced by the Sub6. The goal is to achieve the smoothest frequency response of the whole system:
sub + satellites.
Polarity
This switch inverts the signal polarity on the subwoofer channel (ie 180° phase shift).
Phase
This potentiomer provides some fine ajustment of the phase on the subwoofer channel. Combined with the polarity switch it
can be used to compensate for the spacing between the sub and the main speakers, so to get a coherent soundfield through
a proper time alignment of the different sources.
2.1 Bypass
This input allows for plugging in a control footswitch (not supplied) via a ¼” jack connector.
Turning it active will :
- mute the subwoofer channel
- defeat the high pass filters in the satellites signal paths. The satellites will then be fed with full range signals.
This facility allows for instantaneous comparison between the 2.1 configuration (with sub) and the traditional stereo setup
(without sub) with the same system.
Power indicator
Power "LED" indicator.
SOLO6 BE - TWIN6 BE - SUB6: USING THE SYSTEM
Professional Analog Monitoring System - User manual
9
SYSTEM
Frequency response
40Hz - 40kHz
Maximum SPL
113dB SPL (peak @ 1m)
ELECTRONIC SECTION
Input
Type/Impedance
Connector
Sensitivity
Electronically balanced / 10 kOhms
XLR
Adjustable, +4dBu ou -10dBV
LF amplifier stage
HF amplifier stage
150W rms, BASH
®
technology
100W rms, class AB
Power supply
Main Voltage
Connection
230V (1.6A fuse rating)
115V (3.15A fuse rating)
IEC inlet and detachable power cord
User controls
Input level switch
LF and HF contours (potentiometers)
Power ON/OFF switch, mains voltage selector
Indicator
Power on LED
TRANSDUCERS
Woofer
"W" cone, Focal 6W4370B 6.5" drive unit
High frequency
Focal TB871 inverted Beryllium dome tweeter
Shielding
Integral through concellation magnets or by magnet design
CABINET
Construction
19mm MDF panels with internal braces
Finish
Real red veneer on sides
Dimensions (HxWxD)
330mm x 240mm x 290mm - (13"x9.5"x11.4")
Weight
11kg - (24.2lb)
All specifications are subject to change.
SOLO6 BE: TECHNICAL SPECIFICATIONS
Professional Analog Monitoring System - User manual
10
SYSTEM
Frequency response 40Hz - 40kHz
Maximum SPL 115dB SPL (peak @ 1m)
ELECTRONIC SECTION
Input
Type/Impedance
Connector
Sensitivity
Electronically balanced / 10 kOhms
XLR
Adjustable, +4dBu ou -10dBV
LF amplifier stage
LF/MF amplifier stage
HF amplifier stage
150W rms, BASH
®
technology
150W rms, BASH
®
technology
100W rms, class AB
Power supply
Main Voltage
Connection
230V (2A fuse rating)
115V (4A fuse rating)
IEC inlet and detachable power cord
User controls
Input level switch
Speaker (left/right) switch
LF and HF contours (potentiometers)
Power ON/OFF switch, mains voltage selector
Indicator
Power on LED
TRANSDUCERS
Woofer
2 x "W" cone, Focal 6W4370B 6.5" drive unit
High frequency
Focal TB871 inverted Beryllium dome tweeter
Shielding
Integral through concellation magnets or by magnet design
CABINET
Construction
19mm MDF panels with internal braces
Finish
Real red veneer on sides
Dimensions (HxWxD)
250mm x 500mm x 340mm - (9.8" x 19.7"x 13.4")
Weight
14kg - (30.8lb)
All specifications are subject to change.
TWIN6 BE: TECHNICAL SPECIFICATIONS
Professional Analog Monitoring System - User manual
11
All specifications are subject to change.
SYSTEM
Frequency response
30Hz - 250Hz
Maximum SPL
116dB SPL (peak @ 1m)
ELECTRONIC SECTION
Input
Type/Impedance
Connector
Sensitivity
Left, Right, LFE
Electronically balanced / 10kOhms
Female 3 pins XLR
Variable
Output (to satellites)
Type/Impedance
Connector
Left, Right
Electronically balanced / 50 Ohms
Male 3 pins XLR
Amplifier
350 W rms, BASH
®
technology
Internal processing
and functions
Subwoofer section
Satellite section
Left + Right mono summation
LFE + lo-passed mono sum
24dB/octave variable lo-pass filter
Phase adjustment
Polarity
24dB/octave, defeatable hi-pass filters
with selectable frequency
User controls
Sub level (sensitivity) adjustment
Lo-pass frequency adjustment
Phase adjustment
Polarity switch
Mute
2.1 bypass (controlled by external footswitch)
Hi-pass frequency selection
Hi-pass defeat
Indicators (LED’s)
Power on
Mute
Hi-pass defeat
Power supply
Mains voltage
Connection
230V (T1.6AL fuse rating) or 115V (T3.15AL fuse rating)
IEC inlet and detachable power cord
TRANSDUCERS
Subwoofer
“W” composite sandwich cone, high excursion Focal 11W7670,
270mm (10.6”) drive unit
CABINET
Construction
22mm MDF panels with internal braces
Finish
Real red veneer on sides - Black on body
Dimensions (HxWxD)
380mm x 344mm x 440mm (15” x 13.5”x 17.3”)
Weight
23kg (50.7lb)
SUB6 BE: TECHNICAL SPECIFICATIONS
Professional Analog Monitoring System - User manual
12
Due to constant technological advances, Focal reserves its right to modify specifications without notice. Images may not conform exactly to specific product.
Twin6 Be Solo6 Be
Sub6
SOLO6 BE - TWIN6 BE - SUB6 BE
Système de Monitoring Analog Professionnel
Manuel d'utilisation
Un échantillon de ce produit a été testé et déclaré en conformité avec les directives européennes et autres
normes internationales suivantes :
Compatibilité électromagnétique
EN 55103
EN 61000
Sécurité électrique
EN 60065
Informations de sécurité
Nous vous conseillons de lire toutes les instructions de ce manuel et de tenir compte des consignes de sécurité suivantes.
Après lecture, conservez cette notice dans un endroit sûr afin de pouvoir vous y référer ultérieurement.
Ne pas retirer le panneau arrière. L'intérieur du système ne possède pas de pièces réparables par l'utilisateur. Pour toute
réparation, vous référer à du personnel qualifié. Cet équipement doit être connecté à la terre.
Le câble secteur ne doit être ni plié, ni écrasé, ni noué. Veillez à ne pas tordre le câble au niveau du connecteur et à prévoir
éventuellement des passages protégés pour ne pas le piétiner.
• Utilisez exclusivement les accessoires et les connexions recommandés par le fabriquant.
La vérification par un service professionnel qualifié est nécessaire lorsque le cordon secteur ou les connecteurs sont
endommagés, qu’un liquide ou qu’un objet s’est infiltré, qu’il a été exposé à la pluie ou à l’humidité, qu’il ne fonctionne pas
normalement ou qu’il a subi une chute.
• Évitez la proximité avec des sources de chaleurs (radiateur, halogène, bougie...).
• Ne pas utiliser cet appareil en climat tropical.
• Ne pas exposer cet appareil aux projections d’eau.
• Ne pas poser un récipient rempli de liquide pouvant occasionner un écoulement sur les parties électroniques.
Attention !
Risque de choc électrique
Ne pas ouvrir
Ne pas exposer à l’eau ou à l’humidité
Précautions d’utilisation
Les Solo6 Be et Twin6 Be utilisent un tweeter à dôme inversé en Béryllium pur, capable d’étendre la bande passante à plus de
40 kHz. Sous sa forme solide, ce matériau est inoffensif. Toutefois, de par sa nature, certaines précautions doivent être
appliquées pour ne pas s’exposer à des risques inutiles :
• Le dôme béryllium ne doit jamais être au contact d’une matière abrasive.
Si le dôme béryllium est endommagé sous quelque forme que ce soit, le recouvrir dès que possible sur toute sa surface de
la bande adhésive de protection fournie. Vous la trouverez dans le sachet plastique contenant la notice dédiée au tweeter à
dôme inversé en Béryllium pur. Prendre contact avec le revendeur afin de démonter et de remplacer le tweeter auprès d’un
service compétent chez le distributeur.
Si le dôme est brisé, les particules éventuelles de Béryllium doivent être récupérées avec soin au moyen d’un ruban adhésif
puis être placées dans un sac plastique hermétiquement clos renvoyé en même temps que l’enceinte au revendeur.
Pour plus d’informations, veuillez nous contacter directement à l’adresse suivante : beryllium@focal.com
SOLO6 BE - TWIN6 BE - SUB6 BE
Système de Monitoring Analog Professionnel - Manuel d'utilisation
14
Les enceintes Solo6 Be et Twin6 Be, ainsi que le caisson de grave Sub6 constituent un système d’écoute de contrôle professionnel
de hautes performances et nous vous remercions d’avoir choisi Focal. Ces produits ont été conçus pour allier image sonore
impeccable, extrême précision et réponse en fréquence étendue, dans un format compact adapté à des écoutes de proximité.
Déballage
Une enceinte Solo6 Be ou Twin6 Be est livrée accompagnée des éléments suivants (outre le présent manuel) :
• Un cordon d’alimentation.
• Une carte de garantie.
• Une grille protectrice pour le tweeter Beryllium (notre conseil est de l’enlever pour l’écoute dès qu’il le sera possible).
Un sachet plastique contenant une notice ("Tweeter à dôme inversé en Béryllium), ainsi qu’une bande adhésive à apposer
sur le tweeter en cas d’endommagement du dôme.
Un caisson de grave Sub6 est livré accompagné des éléments suivants (outre le présent manuel) :
• Un cordon d’alimentation.
• Une carte de garantie.
Une grille protectrice pour le subwoofer à membrane "W" (notre conseil est de l’enlever pour l’écoute dès qu’il le sera
possible).
Vérifiez qu’aucun de ces éléments ne manque, et enlevez tous les accessoires du carton.
Afin de ne pas endommager vos produits lors de leur déballage, veuillez respecter les étapes suivantes : ouvrez complètement
les volets du carton. Repliez les côtés. Ôtez la protection supérieure. Soulevez l’enceinte ou le caisson précautionneusement.
Vérifiez que l’emballage ne présente aucun signe de détérioration. Si toutefois il était endommagé, prévenez le transporteur
et le fournisseur. Il est important que l’emballage soit gardé en bon état pour d’éventuelles utilisations futures.
Recommandations
Nous tenons à souligner qu’une pression sonore élevée peut être générée par vos produits, particulièrement en configuration
5.1. Le niveau de distorsion étant faible et le niveau de fatigue de l’utilisateur minime, il n’est pas toujours évident de réaliser
la pression sonore réelle. N’oubliez pas que l’exposition à des niveaux sonores élevés, au-delà d’un certain temps, peut
conduire à une perte irréversible de l’audition.
Garantie
Les Solo6 Be, Twin6 Be et Sub6 sont garantis pièces et main d’oeuvre pour une période de deux ans au sein des pays mem-
bres de l’Union Européenne à compter de la date de livraison au client final. Pour les états hors Union Européenne, merci de
vous référer à la loi en vigueur dans chaque pays.
Pendant la période de garantie, Focal réparera ou échangera le produit défectueux, sous réserve qu’il soit renvoyé, frais de
transport payé par avance, à une antenne Focal agréée. Les dommages causés par des modifications du produit, accidents,
négligence ou mauvaise utilisation ne sont pas couverts par la garantie. Pour plus d’informations veuillez contacter votre
revendeur ou distributeur local.
SOLO6 BE - TWIN6 BE - SUB6 BE : INTRODUCTION
Système de Monitoring Analog Professionnel - Manuel d'utilisation
15
D
B
Midrange
Midrange
E
A
Interrupteur de
sensibilité d'entrée
Connecteur
d'entrée du
signal audio
Sélecteur
de tension
Porte fusible
Contrôle des
hautes fréquences
Contrôle des
basses fréquences
Connecteur
d'entrée du
signal audio
Interrupteur de
sensibilité
d'entrée
Interrupteur de
selection du haut-
parleur médium
Selecteur
de tension
Porte fusible
Contrôle des
hautes fréquences
Contrôle des
basses fréquences
Position A
Gauche / Droite
Position B
Gauche / Droite
Position C
Gauche
Position C
Droite
Position A
Gauche/Droite
Position B
Gauche
Position C
Gauche
Droite
Haut-parleur choisi pour reproduire les médiums avec le switch sur
"enceinte gauche" (left speaker)
Haut-parleur choisi pour reproduire les médiums avec le switch
sur "enceinte droite" (right speaker)
Choix conseillé pour le positionnement
du haut-parleur médium.
Haut-parleur médium
positionné à l'intérieur.
Gauche/Droite
Droite
SOLO6 BE - TWIN6 BE - SUB6
Système de Monitoring Analog Professionnel - Manuel d'utilisation
16
F
C
Connecteurs d’entrées audio
(pour système stéréo/2.1 uni-
quement)
Connecteurs de sorties audio
vers enceintes satellites
(pour système stéréo/2.1
uniquement)
Commutateur du filtre passe-haut
Interrupteur marche/arrêt
du filtre passe-haut
Contrôle de la phase
Contrôle du niveau sonore
Contrôle du filtre passe-bas
Inverseur de polarité
Interrupteur mute
Sélecteur de tension
Connecteur Jack 6.35
pour télécommande
du 2.1 Bypass
Connecteur d'entrée
LFE (pour une
utilisation en
configuration
multicanal :
5.1, 5.2...)
G
SOLO6 BE - TWIN6 BE - SUB6 BE
Système de Monitoring Analog Professionnel - Manuel d'utilisation
17
Solo6 Be
La Solo6 Be est une enceinte professionnelle de contrôle de proximité 2 voies active (2 amplificateurs internes), constituée
d’un haut-parleur grave/médium Focal de 6,5 pouces (16,5 cm) à membrane sandwich composite "W", chargé par un évent
laminaire de grande section et d’un tweeter Focal à dôme inversé en Béryllium pur (fig. A).
Twin6 Be
La Twin6 Be est une enceinte professionnelle de contrôle de proximité ou semi-proximité 3 voies active (3 amplificateurs
internes), constituée de deux haut-parleurs Focal de 6,5 pouces (16,5 cm) à membrane sandwich composite "W" chargés
par un double évent laminaire de grande section et d’un tweeter Focal à dôme inversé en Béryllium pur. Les deux haut-
parleurs de 6,5 pouces reproduisent le grave mais seul l’un d’entre eux (dont on peut choisir le positionnement) reproduit les
fréquences "médium" (fig. B).
Sub6
Le Sub6 est un caisson de grave actif (1 amplificateur interne) pour système de contrôle professionnel. Le transducteur utilisé
est un subwoofer 27 cm Focal à membrane sandwich composite " W" chargé par un évent laminaire de grande section (fig. G).
Le Sub6 peut être utilisé :
- en complément de grave ou d’infra-grave pour des installations stéréo + subwoofer (2.1 ou 2.2), A cet effet la connectique
du panneau arrière du Sub 6 permet le branchement d’une source stéréo traditionnelle (Left In et Right In), mais aussi la
récupération d’un signal (Left Out et Right Out) traité via le filtre " passe-haut" inclus dans le Sub 6, destiné à alimenter des
enceintes associées dites "satellites".
- en canal LFE (Low Frequency Effect) pour une utilisation en système multicanal (5.1, 5.2, 6.1 …) via une entrée spécifique
LFE située sur le panneau arrière du Sub6.
Installation
Alimentation secteur
Après avoir déballé vos produits, vérifiez en premier lieu que la tension d’utilisation sélectionnée est correcte, en fonction de
la tension d’alimentation choisie grâce au sélecteur, vérifiez (et si besoin remplacez) également le fusible, dont l’ampérage
est dépendant de la tension de service (voir caractéristiques du fusible dans le tableau des spécifications).
Vos produits doivent être impérativement reliés à la terre en utilisant le cordon d’alimentation fourni à cet effet.
Connexions d’entrées audio
L’entrée du signal audio s’effectue par l’intermédiaire d’une prise XLR femelle. Cette embase permet la connexion d’une
source de signal symétrique et utilise un schéma de câblage standard :
Pin 1 = masse (blindage)
Pin 2 = point chaud (signal en phase)
Pin 3 = point froid (signal hors phase)
Lorsque la source du signal d’entrée est asymétrique il est usuel de relier le "point froid" (Pin 3) à la masse (Pin 1).
Cette connexion est généralement réalisée au niveau des câbles.
Connexions spécifiques au Sub 6 (fig. G)
Utilisation du Sub6 en configuration stéréo + subwoofer (2.1 ou 2.2)
Left IN : cette entrée est dédiée à recevoir la sortie gauche de votre source (console de mixage, ou autre …).
Right IN : cette entrée est dédiée à recevoir la sortie droite de votre source (console de mixage, ou autre …).
Left OUT : cette sortie est dévolue à l’alimentation de l’enceinte gauche de votre système 2.1. Le signal ainsi récupéré aura
auparavant été filtré par le filtre passe-haut de votre Sub6.
Right OUT : cette sortie est dévolue à l’alimentation de l’enceinte droite de votre système 2.1. Le signal ainsi récupéré aura
auparavant été filtré par le filtre passe-haut de votre Sub6.
Utilisation du Sub6
LFE : cette entrée est dédiée à l’alimentation de votre Sub6 pour une application multicanal (5.1, 5.2, 6.1, 6.2, 7.1, 7.2 …).
L’entrée LFE est uniquement consacrée aux basses fréquences.
SOLO6 BE - TWIN6 BE - SUB6 BE : LES PRODUITS
Système de Monitoring Analog Professionnel - Manuel d'utilisation
18
Positionnement
Les Solo6 Be et Twin6 Be ont été conçues pour être des enceintes de contrôle de proximité et donc être positionnées à une
distance de l’ordre de 1 à 3 mètres de l’auditeur, orientées vers lui. Elles peuvent parfaitement être posées sur le dessus
d’une console de mixage ou encore être mises sur des pieds adaptés ; sachant que dans tous les cas de figure il est vivement
recommandé que la hauteur du tweeter par rapport au sol soit assez proche de celle des oreilles de l’auditeur. En cas de
besoin on peut parfaitement imaginer inverser la disposition normale des enceintes et positionner le tweeter en bas de façon
à se rapprocher de cette règle (fig. C, D).
Les Solo6 Be pourront être positionnées indifféremment verticalement ou horizontalement (fig. C) en fonction de
l’environnement, de préférence orientées vers l’auditeur.
De par leur conception, les Twin6 Be sont plutôt prédisposées à une écoute horizontale bien qu’on puisse également dans
certains cas particuliers les disposer verticalement. Comme vu dans la présentation du panneau arrière, la Twin6 possède
un "interrupteur" permettant de choisir l’emplacement du haut-parleur prévu pour reproduire les fréquences médium
(Voir Utilisation – Contrôles – Interrupteur Speaker Left/Right) – (fig. E). En conséquence, on choisira donc toujours une
configuration "symétrique" ou "miroir" par rapport à l’auditeur. En règle générale on choisira de positionner le haut-parleur
"medium" à l’intérieur pour une meilleure image (fig. F). Dans tous les cas la qualité de l’écoute primera.
Le positionnement optimal du Sub6 varie en fonction de la surface, de la forme et de l’acoustique de la pièce d’écoute. Nous
vous conseillons donc d’essayer plusieurs emplacements possibles afin de sélectionner celui offrant la meilleure qualité
d’écoute. Il n’est pas rare d’obtenir un résultat optimal en plaçant le Sub6 dans un angle.
SOLO6 BE - TWIN6 BE - SUB6 BE : LES PRODUITS
Système de Monitoring Analog Professionnel - Manuel d'utilisation
19
Rodage
Les transducteurs utilisés dans les Solo6 Be, Twin6 Be et Sub6 sont des éléments mécaniques complexes qui exigent
une période de rodage pour fonctionner au mieux de leurs possibilités et s’adapter ainsi aux conditions de température et
d’humidité de votre environnement. Cette période varie selon les conditions rencontrées et peut se prolonger sur quelques
semaines. Afin d’accélérer le processus, nous vous conseillons de faire fonctionner les différents produits une vingtaine
d’heures à niveau moyen, sur des programmes musicaux riches en basses fréquences. Une fois les caractéristiques des
transducteurs stabilisées, vous pourrez profiter pleinement des performances de vos produits Focal.
Contrôles
Contrôles spécifiques à la Solo6 Be et à la Twin6 Be
Interrupteur Speaker (Left / Right) – Uniquement sur Twin6 Be
Cet interrupteur donne la possibilité à l’utilisateur de choisir lequel des 2 haut-parleurs de 6,5 pouces reproduira le medium.
Par convention le fait de choisir la position Speaker "Right/Droit" aura pour effet de sélectionner le haut-parleur de gauche
(lorsqu’on fait face à l’enceinte) comme celui destiné à reproduire le medium. Inversément le haut-parleur droit (lorsqu’on
fait face à l’enceinte) sera celui choisi lorsqu’on mettra le sélecteur sur Speaker "Left / Gauche". On comprend aisément
l’intérêt d’un tel contrôle pour obtenir la meilleure image possible grâce à la symétrisation des deux enceintes et ceci quelle
que soit la disposition envisagée (fig. E, F).
Interrupteur de sensibilité d’entrée (Input)
La sensibilité d’entrée peut être ajustée en utilisant cet interrupteur à deux positions. La position + 4 dBu convient à un
équipement audio professionnel standard, alors que la position -10 dBV peut être utilisée pour les autres types de sources
fournissant un niveau moins élevé.
Contour "HF"
Ce contrôle permet d’ajuster le niveau des féquences hautes au delà de 5 kHz à ± 3 dB (fig. H).
Contour "LF"
Ce contrôle permet d’ajuster le niveau des fréquences graves en deçà de 150 Hz à ± 6 dB (fig. I). Ce réglage sera très utile en
fonction du positionnement des enceintes sur une console, près d’un mur, dans un coin, on aura tendance à diminuer plus
ou moins ces fréquences.
Indicateur
Un témoin "marche/arrêt" sous forme de "LED" se situe sur la façade avant le l’enceinte à proximité du Logo "Focal".
H I
SOLO6 BE - TWIN6 BE - SUB6 BE : UTILISATION
Système de Monitoring Analog Professionnel - Manuel d'utilisation
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Focal Solo6 Be Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues