Whirlpool YMED7000XW2 Guide d'installation

Catégorie
Sèche-linge
Taper
Guide d'installation
GAS DRYER INSTALLATION INSTRUCTIONS
CANADIAN ELECTRIC DRYER INSTRUCTIONS
INSTRUCTIONS POUR L'INSTALLATION DE LA St_CHEUSE
GAZ (I_.-U. ET CANADA)
I_LECTRIQUE (CANADA UNIQUEMENT)
Table of Contents
DRYER SAFETY .......................................................................... 2
iNSTALLATiON REQUIREMENTS .............................................. 4
Tools and Parts ...................................................................... 4
LOCATION REQUIREMENTS ..................................................... 5
ELECTRIC DRYER POWER HOOKUP-CANADA ONLY ........... 6
GAS DRYER POWER HOOKUP ................................................. 7
iNSTALL LEVELING LEGS .......................................................... 9
MAKE GAS CONNECTION ......................................................... 9
VENTING .................................................................................... 10
Venting Requirements ......................................................... 10
Plan Vent System ................................................................. 11
Install Vent System .............................................................. 12
CONNECT iNLET HOSE ........................................................... 12
CONNECT VENT ....................................................................... 14
LEVEL DRYER ........................................................................... 14
COMPLETE iNSTALLATiON CHECKLIST ............................... 15
DOOR REVERSAL (OPTIONAL) ............................................... 15
Table des mati_res
SECURITE DE LA SECHEUSE..................................................19
EXIGENCES D'INSTALLATION ................................................. 21
Outillage et pi_ces ............................................................. 21
EXIGENCES D'EMPLACEMENT ............................................... 22
SLeCHEUSE leLECTRIQUE RACCORDEMENT A
UALIMENTATION leLECTRIQUE - CANADA SEULEMENT ..... 23
RACCORDEMENT D'UNE SLeCHEUSE A GAZ ........................ 24
iNSTALLATiON DES PIEDS DE NIVELLEMENT ...................... 26
iNSTRUCTiONS POUR LE RACCORDEMENT AU GAZ ......... 26
EVACUATION ............................................................................. 27
Exigences concemant I'_vacuation ................................. 27
Planification du syst_me d'_vacuation ............................ 28
Installation du syst_me d'_vacuation ............................... 30
RACCORDEMENT DES TUYAUX D'ALIMENTATION .............. 30
RACCORDEMENT DU CONDUIT DqeVACUATION ................. 32
R(--GLAGE DE L'APLOMB DE LA Si'-=CHEUSE.......................... 32
ACHEVER UINSTALLATION LISTE DE Vi_RIFICATION ........... 33
iNVERSiON DE LA PORTE (FACULTATIF) ................................ 33
Para una version de estas instrucciones en espa_ol, visite www.Whirlpool.com
iNSTALLATiON NOTES
Date of purchase:
Date of installation:
Installer:
Model number:
Serial number:
NOTES CONCERNANT L'INSTALLATION
Date d'achat:
Date d'installation:
Installateur:
Num_ro de module:
Num_ro de s_rie:
W10423115A
W10423116A =SP
DRYER S_ETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING - ...i.. ofFi,o..
- Clothes dryer installation must be performed by a qualified installer.
- install the clothes dryer according to the manufacturer's instructions and local codes,
= Do not install a clothes dryer with fle×ible plastic venting materials or flexible metal
(foil type) duct. if fle×ible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers. Fle×ible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
= To reduce the risk of severe injury or death, follow all installation instructions.
= Save these instructions.
2
WARNING: For your safety, the information in this manual must be followed to minimize 1
the risk of fire or explosion, or to prevent property damage, personal injury, or death. 1
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
o Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
®Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
= if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSi Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
in the State of Massachusetts, the following installation instructions apply:
[] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] if using a ball valve, it shall be a T-handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
INSTALLATION REQUIREMENW$
TOOLS AND PARTS
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
Flat-blade screwdriver
1/4" and 5/16" nut driver
recommended)
Tape measure
#2 Phillips screwdriver
Level
Pliers
8" or 10" pipe wrench 8" or 10" adjustable wrench
(for gas connections)
Pipe-joint compound
resistant to LP gas
Parts supplied:
Parts package is located in dryer drum. Check that all parts
are included.
NOTE: Do not use leveling legs supplied with dryer if installing
with a pedestal or a stack kit.
Leveling legs (4)
Utility knife
Caulking gun and compound
(new vent installations)
Tin snips (new vent
installations)
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Min. 8" long Torx°* T25
screwdriver
(for door reversal only)
1 ® TORX is a registered trademark of Saturn Fasteners, Inc.
4
Short inlet hose
Rubber washers
Long inlet hose
&
"Y" connector
Parts needed: (Not supplied with dryer)
[] Vent clamps
[] Vent elbows and ductwork
Additional parts may be required, depending in your installation.
Check local codes. Check existing electrical supply and venting.
Read "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Optional Equipment: (Not supplied with dryer)
Refer to your "Use and Care Guide" for information about
accessories available for your dryer.
LOCATION REQUIREMENW$
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at Jeast 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation.
See "Venting Requirements."
[] A separate 15 or 20 amp circuit for a gas dryer or 30 amp
circuit for an electric dryer.
[] If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements".
[] Floor must support dryer weight of 200 Ibs. (90.7 kg).
Also consider weight of companion appliance.
[] Cold water faucets located within 4 ft. (1.2 m) of the water
fill valves, and water pressure of 20 - 120 psi (138 - 827 kPa).
You may use the water supply for your washer using the
"Y" connector and short hose (if needed) which are provided.
[] Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
[] For garage installation, place dryer at least 18" (460 mm)
above floor, if using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
[] The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
iMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
40° F (4° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
DRYER DiMENSiONS
Front view:
381/8 H
(968 ram)
t
3/411 _
(18 ram)
(686 ram)
©
©
* Approx. measurement
Side view:
507/8"
(1292 turn)
311/8"
{790 rnrn)
3/4_I*
{18 ram}
53/4 ll*
(146 turn}
J 31/2,,
(257 ram)
* Approx. measurement
Back view:
53/4 mm_
(146 ram) Vent
3/411"#
(18 ram)
Water inlet
-V
, T.....
,91--143/8"_
(365 ram)
253/4"-ii--_
(654 ram}
61/4"
(159 ram}
297/8"*
(759 ram}
.I1- 61/8,,. _
(156 ram)
Approx. measurement
NOTE: Most installations require a minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with elbow. See "Venting Requirements".
5
Installation Clearances
For each arrangement, consider allowing more space for ease
of installation and servicing; spacing for companion appliances
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or Iouvered door is installed, top and bottom air openings
in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum spacing
allowed.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, floor
moldings, dryer venting, and gas line.
[] Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
[] Companion appliance spacing should also be considered.
Recommended installation clearances {dryer only):
Mobile home installations require:
[] Metal exhaust system hardware, available for purchase from
your dealer. For further information, see "Assistance or
Service" section in your "Use and Care Guide".
[] Special provisions must be made in mobile homes to
introduce outside air into dryer. Openings (such as a nearby
window) should be at least twice as large as dryer exhaust
opening.
For mobile home installation of gas dryers:
[] Mobile Home Installation Hold-down Kit Part Number 346764
is available to order. For further information, see "Assistance
or Service" section in your "Use and Care Guide".
ELECTRIC DR R
FOWER HOOKUFo ONLY
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 4 prong outlet,
Failure to do so can result in death or electrical shock.
', "':-=2
5 n * i i,
(127 rnrn} "
(76 ram)
* 0" (0 mm) spacing is allowed.
Mobile home =Additional installation requirements:
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile home construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240
MH.
It is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
[] To supply the required 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch
circuit.
[]
This dryer is equipped with a CSA
International Certified Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer's final location.
4-wire receptacle
(14-30R)
6
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 8529008.
For further information, please reference service numbers located
in "Assistance or Service" section of your "Use and Care Guide".
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING-" Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS DR R FOWER HOOKUF
ELECTRICAL REQUIREMENTS
!
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
[] 120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNinG-" improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
Explosion Hazard
Use a new CSA international approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram)water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA international for LP (propane or butane) gases
with appropriate conversion.
[] Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate in
the door well of your dryer. If this information does not agree
with the type of gas available, contact your dealer or call the
phone numbers referenced in the "Assistance or Service"
section of your "Use and Care Guide".
LP Gas Conversion:
iMPORTANT: Conversion must be made by a qualified
technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
7
GASSUPPLYLiNE
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
[] If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter
fitting between the stainless steel gas connector and the dryer
gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
[] Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer. See illustration.
[] 1/2" IPS pipe is recommended.
[] 3/8"approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
[] If you are using Natural gas, do not use copper tubing.
[] Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
[] If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length of the
supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON_'*_ttape.
[] Must include shut-off valve
GAS SUPPLY CONNECTION REQUIREMENTS
[] Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe,
as needed to avoid kinking.
[] Use only pipe-joint compound. Do not use TEFLON _t tape.
[] This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard for
connectors for gas appliances, ANSi Z21.24 or CSA 6.10.
BURNER INPUT REQUIREMENTS
Elevations above 2,000 ft. (610 m):
[] When installed above 2,000 ft. (610 m) a 4% reduction of the
burner Btu rating shown on the model/serial number plate is
required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
[] The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
DRYER GAS PiPE
[] The gas pipe that comes out through the rear of your dryer has
a 3/8" male pipe thread.
in the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSi Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) ft. (1.8 m) of
the dryer. The location should be easy to reach for opening
and closing.
E
A !_
B
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve.
*5¾"
(146 ram}
1/2nn
(38 ram)
3/8" NPT dryer gas pipe
* NOTE: If the dryer is mounted on a pedestal, the gas
pipe height must be an additional 10" (254 mm) or
15.5" (394 mm) from the floor, depending on the pedestal
model. For a garage installation, the gas pipe height must
be an additional 18" (460 mm) from the floor.
8
1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
INSTALL LE¥_LING LEGS
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
F1, Prepare dryer for leveling legs
m __ __
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
_E GAS CONNECTION
(gas dryer models only)
"1, Connect gas supply to dryer
A. Flaredmale fitting
B. Non-flared malefitting
B
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. Ifflexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas Do not use
TEFLON ®ttape.
It2, Plan pipe fitting connection (option i; "_
_ J
Examine leveling legs, find diamond marking. Screw legs into
leg holes by hand, use a wrench to finish turning legs until
diamond marking is no longer visible.
Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3, Open shut=off valve
A. Closed valve
B.Open valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Venting Requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
[]
[]
(102 ram)
4" (102 ram) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
[] Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only ifaccessible to clean)
[] Must be fully extended and supported in final dryer location.
[] Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 73/4ft. (2.4 m).
[] The length of flexible metal vent used must be included in
the overall vent system design as shown in the "Vent System
Chart".
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or flexible metal vents. Review "Vent System Chart" and
if necessary, modify existing vent system to achieve best drying
performance.
Exhaust hoods:
[] An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
[] Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
[] Do not use an exhaust hood with a magnetic latch.
Recommended Styles:
Louvered Hood
Acceptable Style:
Angled Hood
Elbows:
Box Hood
[] 45° elbows provide better airflow than 90° elbows.
Be
Clamps:
[] Use clamps to seal all joints.
[] Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct ta }e.
improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
10
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installation:
B
©
H
A. Dryer F. Rigid metal or
B Elbow flexible metal vent
C. Wall G. Vent length
D. Exhaust hood necessary to
E. Clamps connect elbows
H. Exhaust outlet
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit.
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
Optional exhaust installations:
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. If you prefer, you may contact your
local dealer to have the dryer converted.
A B C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
!
Determine vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
[] Use the following "Vent System Chart" to determine type
of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Chart".
Exhaust systems longer than those specified will:
[] Shorten life of dryer.
[] Reduce performance, resulting in longer drying times
and increased energy usage.
The "Vent System Chart" provides venting requirements
that will help achieve best drying performance.
Vent System Chart
Number of Type Box/Iouvered Angled
90° elbows of vent hoods hoods
Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
1 J L
2 Rigidmetal 44 ft. (13.4m) 38 ft. (11.6m)
3
4
Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add
one 90° turn to the chart.
11
Install Vent System
. install exhaust hood
q 12" rnin.
"_--(305 mm)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
iiii
iiiiiiiiiiiiiiiiiiiiiiiiii
!!!!!!!!!!!!!!!!!!!!!!!!!!
iiiiiiiiiiiiiiiiiiiiiiiiii
!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
CONNECT INLET HOSE
The dryer must be connected to the cold water faucet using the
new inlet hoses. Do not use old hoses.
NOTE: Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record hose installation or replacement dates on
the hoses for future reference.
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
1. Turn cold water off, remove hose,
and replace rubber washer
.J
Turn cold water faucet off and remove washer inlet hose.
®
®
Check and see if rubber washer is in the "Y" connector.
Remove old rubber washer from inlet hose and replace with
new rubber washer provided.
If space permits, attach the female end of the "Y" connector
to the cold water faucet. See figure A.
If "Y" connector cannot be attached directly to the cold water
faucet, the short hose must be used. See figure B. Attach
short hose to cold water faucet. Screw on coupling by hand
until it is seated on faucet. Then attach "Y" connector to male
end of the short hose. Screw on coupling by hand until it is
seated on connector.
12
Using pliers, tighten the couplings with additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling
can result.
connector and tighten couplings
Remove protective cap from
water inlet valve. Attach other end
of long hose to fill valve at bottom of dryer
back panel. Screw on coupling by hand until it is seated on
fill valve connector. Using pliers, tighten the couplings an
additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling
can result.
One end of the long hose has a wire mesh strainer inside the
coupling. Attach this end to the "Y" connector. Attach washer
cold inlet hose to other side of "Y" connector. Screw on
coupling by hand until it is seated on connector. Using pliers,
tighten the couplings an additional two-thirds turn.
NOTE: Do not overtighten. Damage to the coupling can result.
Check that the water faucets are turned on.
Check for leaks around "Y" connector, faucet, and hoses.
13
CONNECT _%NT
1, Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2= Move dryer to final location
Move dryer to final location, taking care not to crush or
kink vent or flexible gas line.
After dryer is in place, remove corner posts and cardboard
from under dryer.
LE_L D R
1, Level dryer
Place
level here
mm
Check levelness of dryer from
side to side. Repeat from front to back.
©
NOTE: The dryer must be level for the moisture sensing system
to operate correctly
Not Level LEVEL Not Level
2, Adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench
to adjust legs up or down, and check again for levelness.
Once dryer is level, make sure all four legs are snug against
the floor and the dryer does not rock.
14
COMPLETE INSTALLATION
[_ Check that all parts are now installed. Ifthere is an extra
part, go back through steps to see what was skipped.
[_ Check that you have all of your tools.
[_ Dispose of/recycle all packaging materials.
[_ Be sure the water faucets are on.
[_ Check for leaks around "Y" connector, faucet, and hoses.
[_ Check dryer's final location. Be sure vent is not crushed
or kinked.
[_ Check that dryer is level. See "Level Dryer".
[_ Remove film on console and any tape remaining on dryer.
[_ Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
[_ Read "Dryer Use" in your "Use and Care Guide".
[_ If you live in a hard water area, use of a water softener is
recommended to control the buildup of scale through the
water system in the dryer. Over time, the buildup of lime
scale may clog different parts of the water system, which will
reduce product performance. Excessive scale buildup may
lead to the need for certain part replacement or repair.
Electric Models
[_ Plug into a grounded outlet.
Gas Models
[_ Plug into a grounded outlet.
[_ Check that gas supply is on.
[_ Check for leaks.
[_ Check to be sure that the flexible gas line is not crushed
or kinked.
All Models:
[_ Select aTimed Dry heated cycle, and start dryer. Do not
select Air Only Temperature setting.
If dryer will not start, check the following:
Start button has been pressed firmly.
Dryer is plugged into an outlet and/or electrical supply is
connected.
Household fuse is intact and tight, or circuit breaker has
not tripped.
Dryer door is closed.
This dryer automatically runs an installation diagnostic routine
at the start of its first cycle.
NOTE: You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor will
go away.
DOOR RE %RS (OFTION )
The following instructions are for models with a round-shaped
door.
IMPORTANT: For models with a square shaped door, an
additional kit is needed. Please contact your retailer, or see the
"Assistance or Service" page in your "Use and Care Guide".
Tools needed:
@
Min. 8" long Torx®*T25
screwdriver
#2 Phillips screwdriver
iMPORTANT: If the protective film has not yet been
removed from the dryer, peel the film from the dryer
door before proceeding.
Using a Torx®*T25 screwdriver, remove the 4 screws securing
the door hinge to the dryer and lift up and out to remove the
door. Place the door on a soft towel or other non-scratch
surface. Reinstall the 4 screws in the holes.
1 ® TORX is a registered trademark of Saturn Fasteners, Inc.
15
2. Move the door strike
®
®
®
®
Using a Torx®t T25 screwdriver
®
®
®
®
remove the 2 screws securing
the door strike to the door frame of the dryer. Rotate the
strike 180 ° and attach to the opposite side of dryer door
frame, as shown.
_,!. Remove inner door from outer door
Position the door with the inside of the door facing up.
Using a Phillips screwdriver, remove the 10 screws securing
the inner door to the outer door. Lift off the inner door and
set aside.
Remove outer window assembly
from trim ring
A
Using a Phillips screwdriver, remove the 2 screws from the
outer window retainer and rotate the outer window assembly
clockwise until the square notches line up with the 4 tabs
on the trim ring indicated with arrows in the figure A above.
Then lift out the outer window and retainer up and off the trim
ring and set aside (B).
1 ® TORX is a registered trademark of Saturn Fasteners, Inc.
16
5, Reverse outer window assembly
Handle
9
A
Handle
B
Using a Phillips screwdriver, remove the 4 screws from the
outer window retainer and lift off the trim ring off the window
(A). Rotate trim ring 180° and secure with the 4 screws
removed earlier (B).
6, Rotate and reassemble outer window
assembly to trim ring
Bottom
of
' door
t
Notches
A
B
With the edge with 2 notches at the top, align the notches
on the outer window assembly with the tabs on the trim ring
and lower into place as shown in figure A. Rotate the outer
window assembly counterclockwise to lock tabs into place
(figure B). Using a Phillips screwdriver, secure with 2 screws
removed earlier.
IMPORTANT: Do not overtighten.
17
, Remove hinge and latch
1;' _' Latch
Hinge
Using a Torx®t T25 screwdriver, remove the 3 Torx screws
securing the latch plate and latch backing plate and the 5
screws holding the hinge assembly in place.
9. Reinstall inner door assembly
?
Bottom
of door
Position the door with the inside of the door facing up.
Reinstall the 10 screws securing the inner door to the
outer door.
Reinstall hinge and latch on
opposite sides
Using a Torx®t T25 screwdriver, reinstall the latch plate, latch
backing plate, and hinge assembly on the opposite sides from
which they were removed.
Using a Torx®1" T25 screwdriver, remove the 4 screws on the
dryer. Insert the tabs on the hinge into the mounting slot and
slide down to engage the top tab. Secure in place with
the 4 Torx®t T25 screws removed earlier.
1 ® TORX is a registered trademark of Saturn Fasteners, Inc.
18
SECURITE DE LA SECHEUSE
Votre sdcurit_ et celle des autres est trbs importante,
Nous donnons de nombreux messages de s_curit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous de
toujours lire tousles messages de secufite et de vous y conformer.
Voici le symbole d'alerte de s_curit6.
Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6ces et de blessures graves &vous
et &d'autres.
Tous les messages de securit6 suivront le symbole d'alerte de securit6 et le mot "DANGER" ou
"AVERTISSEMENT". Ces roots signifient :
Risque possible de d_c_s ou de blessure grave si vous ne
suivez pas immddiatement les instructions.
Risque possible de d_ces ou de blessure grave si vous
ne suivez pas les instructions.
Tousles messages de s6curit6 vous diront quel est le danger potentiel et vous disent comment reduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
T - "Risque d'incendie"
m
m
m
L'installation de la s_cheuse & linge doit _tre effectu_e par un installateur qualifi_,
Installer la s6cheuse conform_rnent aux instructions du fabricant et aux codes Iocaux,
Ne pas installer de s_cheuse & linge avec des mat_riaux d'_vacuation en plastique
souple ou un conduit m_tallique souple (de type papier d'aluminiurn), Si un conduit
rm_tallique souple est installS, celui-ci doit _tre d'un type sp_cifique identifi_ par le
fabricant de I'appareil et convenir & une utilisation avec les s_cheuses & linge. Les
rnat_riaux d'_vacuation souples sont connus pour s'affaisser, _tre facilement _cras_s
et bloquer la charpie, Ces situations obstrueront le d_bit d'air de la s_cheuse _ linge et
augrnenteront le risque d'incendie,
Pour r_duire le risque de blessure grave ou de d_c_s, suivre toutes
les instructions d'installation,
Conserver ces instructions.
19
AVERTISSEMENT : Pour votre securit6, les renseignements darts ce manuel doivent
_tre observes pour reduire au minimum les risques d'incendie ou d'e×plosion ou pour
eviter des dommages au produit, des blessures ou un deces.
- hie pas entreposer ou utiliser de I'essence ou d'autres vapeurs ou liquides
inflammables _ proximit_ de cet appareil ou de tout autre appareil _lectrom_nager.
QUE FAIRE DANS LE CAS D'UNE ODEUR DE GAZ :
= Ne pas tenter d'allumer un appareil.
o Ne pas toucher a un commutateur _lectrique; ne pas utiliser le t_lephone se trouvant
sur les lieux.
®I_vacuer tous les gens de la piece, de 1'6difice ou du quartier.
®Appeler immediatement le fournisseur de gaz d'un t_16phone voisin. Suivre ses
instructions.
= A defaut de joindre votre fournisseur de gaz, appeler les pompiers.
- L'installation et I'entretien doivent _tre effectu_s par un installateur qualifi_, une
agence de service ou le fournisseur de gaz.
AVERTISSEMENT : L'odorat ne permet pas toujours la detection d'une fuite de gaz.
Les distributeurs de gaz recommandent I'emploi d'un detecteur de gaz (homologation UL ou CSA).
Pour d'autre information, contacter le fournisseur de gaz local.
En cas de d6tection d'une fuite de gaz, ex6cuter les instructions "Que faire dans le cas d'une odeur de gaz".
IMPORTANT : L'installation du gaz doit se conformer aux codes Iocaux, ou en I'absence de codes Iocaux, au code canadien
d'installation B149.1 du gaz naturel ou du propane.
La s6cheuse doit _tre 61ectriquement reli6e & la terre conform6ment aux codes Iocaux, ou en I'absence de codes Iocaux, au Code
canadien de I'electricit6, CSA C22.1.
Dans I'Etat du Massachusetts, les instructionsd'installation suivantes sont applicables :
[] Les travaux d'installation et r6paration doivent 6tre ex6cut6s par un plombier ou tuyauteur qualifi6 ou licenci6, ou par le
personnel qualifie d'une entreprise licenci6e par I'E_tatdu Massachusetts.
[] Si une vanne 9,boisseau sph6rique est utilis6e, elle doit comporter une manette "T".
[] Si un conduit de raccordement flexible est utilis6, sa Iongueur ne doit pas d6passer 3 pi.
IMPORTANT : Pour mettre I'ancienne s6cheuse au rebut ou pour la remiser, enlever la porte.
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Whirlpool YMED7000XW2 Guide d'installation

Catégorie
Sèche-linge
Taper
Guide d'installation

dans d''autres langues