Real Flame 812LP Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

If the information in this manual
is not followed exactly, a fire or
explosion may result causing
property damage personal injury
or loss of life.
Installation and service must be
performed by a qualified installer,
service agency or gas supplier.
Improper Installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage.
Read the installation, operation
and maintenance instructions
thoroughly before installing or
servicing this equipment.
Save these instructions for
future reference. If you are
assembling this unit for
someone else, give this manual
to him or her to read and save
for future reference.
! !
IMPORTANT
WARNING
SAVE THESE
INSTRUCTIONS
!
DANGER
If you smell gas:
1. Shut o gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and
immediately call your gas supplier or fire department.
!
!
WARNING
WARNING
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use should be
stored in vicinity of this or any other appliance.
For outdoor use only. DO NOT use
for cooking. DO NOT use under any
overhead enclosure.
USC
For Technical Support Please Contact Real Flame® At: 1-800-654-1704
812 LP
Corsica LP Fire Column Owners Manual
2
!
DANGER
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
CARBON MONOXIDE HAZARD
TABLE OF CONTENTS
Important Safety Information
Propane (LP) Dangers and Warnings
Parts List
Assembly Instructions
Lighting Instructions
Care and Cleaning
Gas Component Checks
Troubleshooting
Warranty
3
5
7
8
13
14
15
16
18
3
IF YOU SMELL GAS
• Shut o gas supply to the re column.
• Extinguish any open ame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbors phone.
• Follow the gas suppliers instructions.
• If you cannot reach your gas supplier, call the re department.
WARNING Failure to follow the dangers, warning and cautions in this manual may
result in serious bodily injury or death, or in a fire or an explosion causing damage to
property.
• IMPORTANT NOTICE Read and understand all warnings and precautions prior to
assembly and use of your gas fire column. Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage.
• Note The use and installation of this product must conform to local codes. In the
absence of local codes, use the National Fuel Gas Code, ANSI Z21.97. Reference to
Natural Gas and Propane Installation code CSA B149.1 or Propane Storage and
Handling code B149.2.
Minimum Clearance from Unit to Combustible Materials
72”(182.9cm) from the top; 48” (121.9 cm) from all sides and back. Do not locate this
fire column under any overhead enclosure.
• This gas re column and its individual shuto valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 of psi (3.5 kPa). The appliance must be isolated from the gas supply
piping system by closing its individual manual shuto valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psi
(3.5 kPa).
• Keep these instructions for future reference. If you are assembling this unit for
someone else, give this manual to him or her to read and keep for future reference.
• This gas re column must be used ONLY outdoors in a well-ventilated space and shall
NOT be used inside a building, garage, or any other enclosed area.
• DO NOT use this outdoor gas re column for indoor heating. TOXIC carbon monoxide
fumes can accumulate and cause asphyxiation.
• NEVER LEAVE this gas re column unattended when in use.
• Children should be alerted to the hazards of high surface temperatures and kept at a
safe distance while your fire column is in use.
• Do not store or use gasoline or other ammable vapors and liquids within 25 feet
(7.62m) of this or any other appliance.
• Do not store any combustible materials in the base enclosure.
• The use of alcohol, prescription or non-prescription drugs may impair an individual’s
ability to properly assemble or safely operate this outdoor fire column.
IMPORTANT SAFETY INFORMATION
!
WARNING FIRE COLUMN IS FOR OUTDOOR USE ONLY
4
• DO NOT use in an explosive atmosphere. Keep gas re column area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
• This outdoor re column is NOT to be operated by children. Young children should be closely
supervised when in the vicinity of this outdoor fire column.
• This outdoor re column is not to be installed or used in or on recreation vehicles and/or boats.
• Always use in accordance with all applicable local, state and national codes. Contact your local
fire department for details on outdoor burning.
• Use the same precautions you would with any open re when using this outdoor re column.
• DO NOT burn solid fuels such as: wood, charcoal briquettes, lump charcoal, manufactured
logs, driftwood, trash, leaves, paper, cardboard, plywood, painted or stained or pressure
treated wood in this outdoor fire column.
• DO NOT use this outdoor re column until it is COMPLETELY assembled and all parts are
securely fastened and tightened.
• DO NOT store another LP gas tank within 10 feet (3.05 m) of this outdoor re column while it
is in operation.
• DO NOT use this outdoor re column near automobiles, trucks, vans or recreational vehicles.
• DO NOT use this outdoor re column under any overhead structure or near any unprotected
combustible constructions. Avoid using near or under overhanging trees and shrubs.
• Always use this outdoor re column on a hard, level non-combustible surface such a concrete,
rock or stone. An asphalt or blacktop surface may not be acceptable for this purpose.
• DO NOT use this outdoor re column if any part has been under water. Immediately call a
qualified service technician to inspect the fire column and to replace any part or control
system and any gas control which has been under water.
• DO NOT wear ammable or loose clothing when operating this outdoor re column.
• DO NOT use in windy conditions.
• Keep all electrical cords away from a hot outdoor re column.
• Certain areas of this outdoor re column when in use will become too hot to touch. Do not
touch hot surfaces until the unit has cooled unless you are wearing protective gear such as
insulated pot holders or heat resistant gloves or mittens to avoid burns.
• DO NOT hang or place clothing or other ammable materials on or near the gas re column.
• Any guard or other protective device removed for servicing the re column must be replaced
prior to operating the fire column.
• DO NOT attempt to move or store this outdoor re column until all parts are cool.
• DO NOT lean over this outdoor re column when lighting or when in use.
• Use only the regulator and hose assembly provided. The replacement regulator and hose
assembly shall be that specified by the manufacturer.
• DO NOT attempt to disconnect the gas regulator from the tank or any gas tting while the
outdoor fire column is in use.
• Always disconnect the LP tank when the unit is not in use.
• DO NOT sit or lean on the re column when the unit is in operation.
• DO NOT throw anything onto the re when the unit is in operation.
• Lava rocks are very hot; please keep the children or pets away at a safe distance.
• It is essential to keep the outdoor re column valve compartment, burner, and circulating air
passages clean. Inspect outdoor fire column before each use.
•Prior to each re column operation, check the burner components for evidence of excessive
abrasion or wear by looking through the access panel. If if any part is damaged, it must be
replaced before using the gas fire column. Please call Real Flame at 1-800-654-1704.
IMPORTANT SAFETY INFORMATION (continued)
5
• Before each use, remove the lava rocks. Examine the burner and its components. If dirty,
clean with a soft brush and soapy water solution. Examine the area around the burner;
any dirt or foreign material, such as spider webs or nests in this area should be removed.
If it is evident that the burner is damaged, the fire column must not be used. The burner
assembly cannot be replaced. Please contact Real Flame at 1-800-654-1704 for technical support.
• Place the hose out of the pathways where people may trip over it. Do not place the hose in
areas where it may be subjected to accidental damage.
LP GAS
LP gas is ammable and hazardous if handled improperly. Become aware of the
characteristics before using any LP gas product.
Propane Characteristics
• Flammable, explosive under pressure, heavier than air and settles in pools in low areas.
• In its natural state, propane has no odor. For your safety, an odorant has been added.
• Contact with propane could burn your skin.
• Propane is extremely ammable and hazardous if handled improperly.
LP GAS WARNINGS
• Cylinders must be stored outdoors in a well-ventilated area out of reach of children.
• Disconnected cylinders must have threaded valve plugs tightly installed and must not be
stored in a building, garage or any other enclosed area.
• Never use a propane cylinder with a damaged body, valve, collar or footing.
• Dented or rusted propane cylinders may be hazardous and should be checked by your
propane gas supplier.
• Be sure to use only one 1 lb (465 g) LP gas cylinder in this appliance.
• Only tanks marked “propane” may be used.
• The LP gas supply tank must be constructed and marked in accordance with the
Specifications for LP gas LP gas tanks of the U.S. Department of Transportation (DOT) or
the National Standard of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for
the Transportation of Dangerous Goods; and Commission.
• LP gas tank must be arranged for vapor withdrawal.
• The LP gas tank must have a listed overlling prevention device (OPD) and a QCCI or
Type I (CGA810) LP gas tank connection.
ATTENTION: Any alteration of the outdoor fire column that is not specifically directed in
the operations manual will void manufacturer warranty.
IMPORTANT SAFETY INFORMATION (continued)
PROPANE (LP) DANGERS AND WARNINGS
!
WARNING
This outdoor fire column is for use with liquid propane (LP) gas only. The conversion to or
attempted use of natural gas in this outdoor fire column is dangerous and could result in
serious personal injury, or property damage.
6
• LP gas cylinder must contain a shut-o valve as specied in the Standard for Compressed
Gas Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
• Never use an LP gas tank with a damaged body, valve, collar, or footing. Dented or rusted
LP gas tanks may be hazardous and should be checked by your LP gas supplier prior to
use.
• The LP gas tank should not be dropped or handled roughly.
• Tanks must be stored outdoors out of the reach of children. Do NOT store in a building,
garage, or any other enclosed area.
• Never store your LP gas tank where temperatures can reach over 125°F.
• Do not store the LP gas cylinder in direct sunlight or near a source of heat or combustion.
• Never keep a lled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure
to increase, which may open the relief valve and allow gas to escape.
• Place dust cap on valve outlet whenever the LP gas tank is not in use. Only install the
type of dust cap on the LP gas tank valve outlet that is provided with the LP gas tank
valve. Other types of caps or plugs may result in leakage of propane.
a. Do not store a spare LP gas cylinder under or near this appliance.
b. Never fill the LP gas cylinder beyond 80% full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or
serious injury may occur.
• LP gas cylinders should be lled only by a certied LP gas dealer.
• The pressure regulator is set for 11 inches of water column (pressure).
• The maximum inlet gas pressure for this appliance is 14 inches of water column pressure.
• Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer,
motor home or house.
• Always use the pressure regulator and hose assembly provided with the appliance to connect to
a LP gas cylinder. Never connect to an unregulated LP gas supply. For technical support contact
Real Flame at 1-800-654-1704.
• Hand turn the 1 lb LP gas tank. Never use tools. If the tank will not turn by hand, do not
try to repair it. Call a Certified Gas Technician. The use of force or any self attempted repair may
result in a fire or explosion.
Connecting your gas cylinder
Before connection, be sure that there is no debris caught in the head of the gas cylinder, head of
the regulator valve or in the head of the burner and burner ports. Connect screw on the 1 lb LP
tank and hand-tighten firmly. Disconnect the propane cylinder from the appliance when the unit is
not in use. DO NOT obstruct the flow of combustion air and ventilation air to the burner.
PROPANE (LP) DANGERS AND WARNINGS
7
PARTS LIST
Lava Rock 05603408 1
Fire Column 1
Door 0812LP04 1
Vinyl Cover 08120100 1
1
1
2
2
3
4
4
3
8
ASSEMBLY INSTRUCTIONS
1
Place lava rock by hand. DO NOT dump bag out into tray to avoid
clogging the burner with dust. Position the lava rock (1.2kgs) to a level
about 1” above the top of the burner. Make sure that you do not block
the igniter box with lava rock to ensure proper ignition.
Lava
Rock
(5)
Do not cover
9
ASSEMBLY INSTRUCTIONS
2
Install a AAA Battery into the electronic igniter as shown in the
diagram below.
Note: Battery not included with unit.
10
ASSEMBLY INSTRUCTIONS
3
Adjust the feet of the unit to insure that the column is level. To adjust
the feet turn them clockwise or counter-clockwise.
11
4
Check to make sure there is no debris in the head of the LP gas
tank or in the head of the regulator valve. Make sure you check the
burner and burner ports as well.
Connect the tank to the valve by threading clockwise. Hand tighten
only. Disconnect when not in use.
Connecting the LP Gas Tank
ASSEMBLY INSTRUCTIONS
12
6
Check for leaks at these locations
!
!
WARNING Before using this outdoor fire column, make
WARNING Failure to inspect this connection or
sure you have read, understand and are following all
information provided in the Important Safety Information
section of this manual. Failure to follow those instructions
can cause death, serious injury or property damage.
follow these instructions could cause a fire or an
explosion, which can cause death, serious bodily
injury, or damage to property.
Prior to each gas fire column operation, check the valve
assembly for evidence of excessive abrasion or wear
though the access panel on the side of the base. Replace
the access panel prior to operating fire column.
BURNER CONNECTIONS
Make sure all of the connections are tight. If your unit
was assembled for you, visually check all connections.
Please refer to diagram for proper installation.
If any part appears to be incorrect please contact Real
Flame at 1-800-654-1704 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, attach the 1 lb
LP gas tank.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF,
reconnect and re-test. If you continue to see bubbles
after several attempts, disconnect LP gas source and
contact Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.
PRE-USE INSTRUCTIONS
13
7
1. Read and understand all operating instructions before lighting
Ensure that all protective film has been removed from stainless
burn tray prior to lighting.
2. Burner control knob must be in the “OFF” position.
3. Connect propane (LP) cylinder (see above pages).
4. Push and hold igniter button to create sparks.
5. While holding the igniter button with one hand, use your other
hand to push and turn the control knob to the “LIGHT” position
to light the burner.
6. Keep Burner Control Knob pressed in for 15-30 seconds after
ignition.
7. If ignition does not occur in 30 seconds, turn control knob to the
“O” position and turn gas o at the source, wait 5 minutes until
gas has cleared and repeat lighting procedure.
8. After lighting, rotate the Burner Control Knob counter clockwise
to “Low” setting. Observe ame, make sure all burner ports are
lit. Flame height should be no higher than 13 inches tall.
9. Adjust the flame to the desired height with the
control knob.
Using a Long Match or Lighter
1. Prior to lighting, use a shovel to move lava rocks for
access to the burner.
2. Wearing heat resistant gloves, position the burning
long match or burning butane lighter near the side of
the burner. DO NOT lean over the fire column while
lighting!
3. Turn control knob counterclockwise to “LIGHT”.
4. Remove long match/long butane lighter.
5. After lighting, use a shovel and heat resistant gloves
to carefully move the lava rocks back into their proper
position and replace the glass panel.
6. After lighting, rotate the Burner Control Knob counter
clockwise to “Low” setting. Observe ame, make sure
all burner ports are lit. Flame height should be no
higher than 13 inches tall.
7. Adjust the flame to the desired height with the control
knob.
When using this method to light
your fire column use heat resistant
gloves and follow the step by step
instructions. Failure to do so could
result in severe injury.
If burner flame goes out during operation, immediately
turn the control knob “OFF” and let the gas clear a
minimum of 5 minutes before attempting to re-light the
fire column.
Please refer to the trouble shooting pages for
additional support, beginning on page 18.
Using the Ignitor
!
!
WARNING
WARNING
LIGHTING INSTRUCTIONS
PUSH IN
AND
TURN
14
WARNING DO NOT inspect this outdoor replace until the re is COMPLETELY out.
WARNING
DO NOT move or store this re column unless the re is COMPLETELY out and
cool to the touch.
WARNING DO NOT tamper with this appliance. This is DANGEROUS and will void the
warranty. Any part found to be faulty must be replaced with an approved part, confirmed by
manufacturer. For technical support contact Real Flame at: 1-800-654-1704.
!
!
!
Inspecting
This outdoor fire column must be inspected regularly to insure that the product is
safe to use and to extend product life.
1. Check the burner to make sure it is securely in place.
2. Check the Venturi tube to make sure it is clear and free of insects, spider nests and other debris.
3. Check all gas connections for leaks.
4. Check ignition system to insure proper sparking.
5. Check components for any signs of damage, rust or excessive wear.
6. If damage to any component is detected, DO NOT operate until the proper repairs have been
made.
1. Remove tank and store in a cool, dry location outdoors, away from children.
2. Carefully remove rock filler and store components flat to protect them from breakage.
3. ALWAYS cover your outdoor replace when not in use with the cover provided with the unit.
4. Store in a cool, dry location away from children and pets.
General Care and Cleaning
This outdoor fireplace should be cleaned regularly to ensure safe use and extend product life.
Note: After repeated use, a slight discoloration of the finishes may occur
.
Column
1. Wipe exterior surfaces with a mild dish washing soap or baking soda, then rinse clean with
water.
Stainless Steel
1. For general cleaning use warm water, soap, ammonia, or detergent apply with a soft cloth or
sponge.
2. For finger prints or smears use 3M Stainless Steel Cleaner and Polish, Arcal 20, Lac-O-Nu,
LuminWash, O’Cedar Cream Polish, or Stainless Shine, this will provide a barrier file to
minimize ngerprints.*
3. For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish, Allchem
Concentrated Cleaner, Samae, Twinkle, Cameo Copper Cleaner, Liquid Nu Steel, Copper’s or
Revere Stainless Steel Cleaner, apply using a soft cloth in the same direction of the polish
lines.*
* Use of proprietary names is intended only to indicate a type of cleaner and does not constitute endorsement. Omission of any
proprietary cleanser does not imply its inadequacy. All products should be used in strict accordance with instructions on package.
Storage
CARE AND CLEANING
15
GAS COMPONENT CONNECTION CHECKS
Pilot
Housing
Pilot
Housing
Burner
Do not block
opening
CORRECT
INCORRECT
If the burner will not light or stay lit, please perform the following checks.
1. Make sure the electrode wire is correctly connected.
Both electrode wires must be fully inserted into the igniter box.
2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris
between the igniter pin, thermocouple and the burner tube.
Burner
16
Possible Cause 1: No Gas Flow.
-Check if the LP gas tank is empty. If empty, replace the tank. If the propane
tank is not empty, refer to “Problem: Sudden drop in gas ow” on the
following page.
Possible Cause 2: 1 lb tank not fully connected.
-Turn the tank about one half to three fourths a turn, until you
feel a solid stop. Do not use tools, tighten by hand only.
Possible Cause 3: Obstruction of gas ow.
- Check for bent or kinked hose.
Possible Cause 4: Burner ports clogged or blocked.
-Reference “Problem: Irregular ame pattern” on the
following page. Clean the burner ports as described
there.
Possible Cause 1: Electrode and burners are wet.
-Wipe dry with cloth.
Possible Cause 2: Igniter battery is dead or backwards.
-Check that the AAA battery is inserted correctly in the igniter (see page 9) or
replace the battery.
Possible Cause 3: Igniter Pin cracked or broken - sparks at crack.
-Call Real Flame at 1-800-654-1704 for technical support.
Possible Cause 4: Wire loose or disconnected.
-Reference page 15, step 1, reconnect wire. Call Real Flame at 1-800-654-1704.
Possible Cause 5: Wire is shorting (sparking) between igniter and electrode.
-Call Real Flame at 1-800-654-1704 for support.
Possible Cause 6: Igniter Pin not correct distance from burner.
- Make sure the tip of the Igniter pin is 5 mm away from
the burner.
Possible Cause 7: Bad Igniter.
-Call Real Flame at 1-800-654-1704 for support.
TROUBLESHOOTING
Problem: Burner will not light using igniter
For Technical Support Contact Real Flame at: 1-800-654-1704
Problem: The re column emits a lot of black smoke when in use
Problem: Burner will not light with match
Possible Cause: Flame is being obstructed at burner ports.
-Make sure that the gas ports on the burner are free
of any lava rocks so that the flame can flow naturally.
5 mm
Burner
Burner
Ports
Burner
Ports
Igniter Pin
(Electrode)
17
Possible Cause: Burner ports are clogged or blocked.
-Clean burner ports. Do this by inserting a
paperclip into each of the burner ports to
ensure they are not clogged. WARNING: Make
sure burner is not on and the gas supply has
been properly disconnected. Allow 15 minutes
for unit to cool before touching it.
TROUBLESHOOTING
If these troubleshooting steps are unable to resolve the problem,
please call Real Flame at: 1-800-654-1704
Possible Cause 1: High or gusting winds.
-Increase ame to “HIGH” setting.
Possible Cause 2: Low on LP gas.
-Replace LP gas tank.
Possible Cause 3: Excess ow valve tripped.
-Refer to “Problem: Sudden drop in gas ow”
Possible Cause 1: Ice has built up on the outside of the LP gas tank because the
vaporization process is too low.
-Turn the control knob to “OFF”. Replace with a spare LP gas tank and resume
burning. Store the spare LP gas tank in a well ventilated area, away from children.
Possible Cause 1: Out of gas.
-Call your local gas company.
Possible Cause 2: Excess ow safety device may have been activated.
- Turn control knob to “OFF”, wait 30 seconds and light outdoor replace. If
flames are still too low reset the excessive flow safety device by turning o
the control knob and disconnecting the 1 lb LP tank. Turn burner
control knob to “HIGH”. Wait 1 minute. Turn burner control knob o.
Reconnect the tank and perform a leak check at tank connection. Wait 30 seconds
and light the fire column.
Problem: Sudden drop in gas ow, or a reduced ame height
Problem: Irregular ame pattern, ame does not run the full length of the burner
Problem: Flame blow out
Problem: Flame seems to lose heat when burning in cold weather -
temperature below 50°F
Burner
Ports
18
Warranty
Jensen Metal Products, Inc., doing business as Real Flame®, warrants Real Flame vent-less
fireplaces and accessories to be free from defects in parts and workmanship under normal use
and service for a period of 90 days from the date of purchase. In the event of such defects
Real Flame will, at its option, replace the defective product or refund the purchase price. The
foregoing is the exclusive remedy and Real Flame disclaims all other warranties, including any
implied warranty of merchantability or fitness for a particular purpose. In addition, Real Flame will
not be responsible for consequential damages in excess of the purchase price of the product on
which such liability is based. Electric fireplaces carry a one-year warranty on the electric firebox
only.
Return Policy
You may return your purchase within 90 days of receipt. No refunds will be issued for incomplete
or unauthorized returns. All returned products must be 100% complete, adequately packaged in
original packaging and in resalable condition. Products that have been assembled or modified will
not be eligible for return. All items must be returned in their entirety, meaning all items included
must be returned together. No returns or exchanges on discontinued items. Please begin the
return process by contacting the store or company where you bought your Real Flame item.
Replacement Parts
In the event that an item has been lost or damaged either by the manufacturer or in shipping
you may request a replacement. Replacement parts are not available for all units and only given
at Real Flame’s discretion. We will assess any damage and find a solution, which could include
ordering and shipping a replacement to you. No replacements are available for discontinued
items or repackaged (open box) products. Please call Real Flame Customer Service at 800-
654-1704 for replacement parts before returning the damaged item. Please have the following
information, which can be found in your instruction manual, ready before you call Customer
Service.
• Model Number of Item
• 4-8 digit Part Number
• Lot Code Number
• Shipping Address
• A picture of the damaged item may be requested. Pictures should be
sent to custserv@realflame.com
Incorrect Order Received
If you received something other than you ordered, please contact Real Flame Customer Service
at 800-654-1704 within 48 hours of receiving the item.
Please refer to www.Realflame.com for our complete return guidelines and policies.
Warranty & Return Policies
Real Flame®
7800 Northwestern Ave.
Racine, WI 53403
Customer Service: 1-800-654-1704 in USA
Service à la clientèle: 1-800-363-6443 in Canada
custserv@realflame.com
19
La négligence à suivre
scrupuleusement les instructions
contenues dans ce manuel peut
provoquer un incendie ou une
explosion occasionnant des
dommages à la propriété, des
blessures sérieuses et même la mort.
L’installation et l’entretien doivent
être faits par un installeur qualifié,
une compagnie d’entretien ou un
fournisseur de gaz.
Une installation, une mise au point,
une modification ou un entretien
inappropriés peuvent occasionner
des blessures ou des dommages à la
propriété.
Lire attentivement les instructions
concernant l’installation, l’utilisation et
l’entretien avant d’installer ou d’utiliser
l’appareil.
Garder ces instructions pour une
consultation future. Si vous assemblez
cet appareil pour quelqu’un d’autre,
lui donner le manuel pour lecture et
consultation futures.
!
IMPORTANT
!
AVERTISSEMENT
!
AVERTISSEMENT
CONSERVER CES
INSTRUCTIONS
!
DANGER
Si vous percevez une odeur de gaz :
1. Couper l’alimentation en gaz de l’appareil.
2. Éteindre toute flamme nue.
3. Si l’odeur persiste, vous éloigner de l’appareil et
appeler immédiatement votre fournisseur de gaz ou le
service des incendies.
!
AVERTISSEMENT
Ne pas entreposer ou utiliser d’essence, de vapeurs
ou liquides inflammables à proximité de cet
appareil ou de tout autre appareil.
Une bouteille de gaz PL non connectée et non
utilisée ne devrait pas être entreposée à proximité
de cet appareil ou de tout autre appareil.
Pour un usage extérieur exclusivement.
NE PAS utiliser pour la cuisson. NE PAS
utiliser sous une enceinte couverte.
USC
Pour le support technique S’il vous plaît nous contacter: 1-800-654-1704
812 LP
Manuel d’utilisation de la colonne-foyer Corsica
2
!
DANGER
Cet appareil peut produire du monoxyde
de carbone, lequel est toujours inodore.
Utiliser cet appareil dans un endroit fermé
peut causer la mort.
Ne jamais utiliser cet appareil dans un
espace fermé comme une fourgonnette
de camping, une tente, une voiture ou à
l’intérieur de la maison.
DANGER DE MONOXYDE DE CARBONE
TABLE DES MATIÈRES
Instruction de sécurité importante
Avertissements et dangers du Propane (PL)
Liste des pièces
Instructions pour l’assemblage
Instructions pour l’allumage
Soins et entretien
Vérications entourant le gaz
Dépannage
Garantie
3
5
8
9
12
13
14
15
17
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Real Flame 812LP Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues