16
EN
For reasons of product liability, we must also draw your attention to the
following: Regularly check the calibration before use, after transport and
after extended periods of storage. We also wish to point out that absolute
calibration is only possible in a specialist workshop. Calibration by yourself
is only approximate and the accuracy of the calibration will depend on the
care with which you proceed.
The ADS does not activate the monitoring function until 30 seconds
after the laser levelling procedure has been completed (set-up phase).
Long flash of tilt LED at 1 second intervals during the set-up phase
and short flash of LED when ADS is active.
!
Special product features and functions
The rotary laser aligns itself automatically. It is set to the
required initial position (to within an operating angle of ± 4°) and the
automatic system then performs the necessary fine adjustment, with
three electronic measurement sensors detecting the X, Y and Z axes.
The anti-drift system (ADS) prevents erroneous or inaccurate
measurements. How it works: continuous monitoring of the alignment of
the laser is activated 30 seconds after the ADS is switched on. If the device
moves due to the influence of external factors or the laser loses its height
reference, the laser will come to a standstill. Additionally, the laser flashes
and the tilt LED is lit continuously. To continue working, press the tilt button
again or switch the device off then on again. Erroneous and inaccurate
measurements are thus prevented simply and reliably.
The ADS is not active following switch-on. Once the device has been set
up, press the tilt button to activate the ADS, enabling you to protect the laser
from changes in position caused by the device being disturbed by external
factors. The tilt LED flashes to indicate that the ADS function is active; see
the diagram.
– In public areas shield off the laser beam with barriers and partitions
wherever possible and identify the laser area with warning signs.
– Tampering with (making changes to) the laser device is not permitted.
– This device is not a toy - keep out of the reach of children.