PC 101 Power Controller • Setup Guide
The Extron PC 101 Power Controller provides remote power management for AV devices. When paired with an Extron controller
or control processor with relays, such as the MediaLink MLC 226 IP or the IP Link IPL 250, the PC 101 can be set up to power an
AV device on or off at scheduled times. It has a contact closure control input for remote control of a device and a tally port that
can be used for status feedback. Its power rating of 100-240 VAC, 50-60 Hz, provides worldwide compatibility. A front panel test
switch enables manual power cycling for setup and test purposes. This guide provides instructions for an experienced installer to
set up and connect a PC 101.
NOTE: For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics,
see the Extron Safety and Regulatory Compliance Guide at www.extron.com.
ATTENTION:
Use electrostatic discharge precautions (be electrically grounded) when making connections. Electrostatic discharge
(ESD) can damage equipment, although you may not feel, see, or hear it.
Prenez des précautions contre les décharges électrostatiques (soyez électriquement relié à la terre) lorsque vous
effectuez des connexions. Les décharges électrostatiques (ESD) peuvent endommager l’équipement, même si vous ne
pouvez pas le sentir, le voir ou l’entendre.
Rear Panel Features and Connections
FF
E
EDD
C
CBB
A
A
TALLY
1+V
CONTACT
IN
1G
10A MAX
10A MAX
INPUT
OUTPUT
PC 101
T
O
R
E
S
E
T
P
R
E
S
S
10
BREAKER
100-240 ~ 50-60Hz 100-240 ~ 50-60Hz
Figure 1. PC 101 Rear Panel
A
Breaker — 10 A rated circuit breaker. When an over
current condition occurs, the PC 101 stops outputting
AC current and ceases to function. Press this button
to manually reset the circuit breaker.
B
Input — Power input with a 6-inch IEC cable
attached. Connects AC power to the PC 101.
C
Output — Power output with a 24-inch (60 cm) IEC
cable attached. Connects power to an output device.
D
Output power LED — This green LED lights when
AC power is supplied to the Output connector. (The
front panel contains an output power LED which
performs the same function. Both LEDs reflect the
same status for the Output port.)
Make sure that the device being controlled can
support an AC power cycle.
E
Tally port — 2-pole captive screw port
that toggles between high and low states.
An LED indicator can be connected to
this port to show when the connected
device is receiving power from the PC 101.
When the AC output is off, the tally
pin is in the high (oating) state.
When AC power is present on the
output, tally pin 1 toggles to the low
(grounded) state.
F
Contact In port — 2-pole captive screw contact
closure input connector.
When pins 1 and G (ground) of this connector are
shorted together, the AC input passes power to the
output. If an LED is connected to the Tally port (
E
),
the LED lights when power is passed.
ATTENTION:
No greater than 10 A of current should pass through the unit.
Pas plus de 10A de courant ne devrait passer au travers de l’unité.
TALLY
1+V
+5
V
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8113.6800
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Installation Steps
1. (Optional) Mount the PC 101 to a rack shelf or furniture using mounting hardware such as an Extron under-desk mount kit.
2. Connect the male IEC connector on the 6-inch input cable (see figure 1,
B
, on the previous page) to a 100-240 VAC power
source, using a standard IEC power cord.
3. Connect the female IEC connector on the 24-inch output cable (
C
) to the device to be controlled. In many instances the
output cable can be plugged directly into the device being controlled. Alternatively, you can use the provided IEC adapter.
4. Connect a push button or control processor to the Contact In port (
F
) to enable the PC 101 to turn the Output connector
power on and off by contact closure. You can optionally monitor the status by connecting an LED from the +V (+5 volts) pin
to pin 1 of the Tally port (
E
).
CAUTION:
When using the NEMA 5-15R receptacle adapter, connect the equipment only to a nominal 120 VAC source of supply.
Replacement of fuses should be by service personnel only.
ATTENTION:
Lorsque vous utilisez la prise de courant NEMA 5-15R, veillez à ne connecter le dispositif qu’à une source d’alimentation
nominale de 120 Vca.
Le remplacement des fusibles doit être effectué uniquement par un technicien qualié.
Front Panel Features
BB
C
C
D
D
E
E
A
A
OUTPUT POWER
TEST
POWER
CONTACT
PC 101
Figure 2. PC 101 Front Panel
A
Input Power LED — Lights when the unit is powered
on.
B
Contact LED — Lights when the Contact input port is
active.
C
Power LED — Lights when AC power is being
supplied to the rear panel Output connector (same
function as the Cable Receptacle Power LED on the
rear panel).
D
Test button — This button tests the power connection
to the output. Use a small screwdriver to press this
recessed button to enable AC power to pass to the
output. Power is off by default when AC power is first
applied to the PC 101. Subsequent presses of the
button toggle power to the output on and off.
E
Power test LED — This LED is off by default when
AC power is applied to the unit. Thereafter, the LED
toggles on and off with each press of the Test button.
Application Diagram
INPUT
LAN
P
O
WER
12V
500mA
MAX
1
2
3 4
CO
M
3
IR
3
S
G S G
Tx
Rx
4
RE
LAY
3
4
C
O
M1
Tx
Rx
R
TSCTS
C
O
M 2
IR
1
S
G
S G
Tx
Rx
2
RE
LAY
1
2
TALLY
1
+V
C
O
N
T
ACT
I
N
1 G
8A
MAX
8A MAX
INPUT
OUTPUT
PC 101
BREAKE
R
100-
240 ~ 50-
60Hz
100-240 ~ 50-60Hz
T
O
R
E
S
E
T
10
Extr
on
To Display
Adapter
Flat Panel Display
Relay
Ethernet
Ethernet
Extron
IPL 250
IP Link Control
Processor
TCP/IP
Network
Extron
TLP 710TV
7" TouchLink
Touchpanel
Extron
PC 101
Power Controller
GlobalViewer
A
V Resource
Management and
Remote Control
A
pplication
Figure 3. PC 101 Application Using an IPL 250
NOTE: Use the provided IEC adapter if the PC 101
output cable cannot plug directly into the device to
be controlled.