Vari-Lite VL1100 LEDHP Guide de démarrage rapide

Taper
Guide de démarrage rapide

VL 1100 LED Luminaire
QuickStart Guide
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
1 24 April 2017 02.1602.0001
Introduction
About This Guide
This Quickstart Guide is intended for a knowledgeable user to unpack, install, and use the VL1100 LED™ Luminaire in a short time period.
For the complete manual in PDF format, please visit our web site at www.philips.com/entertainmentlighting and click the user manual
download link on the product downloads page. The complete manual provides you all information related to accessories, menu structures,
DMX channel mapping/modes, and care for your new luminaire.
Read this manual in its entirety before operating luminaire. Keep this guide for future reference.
WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or
others.
AVERTISSEMENT: Il est important de lire toutes les instructions de sécurité et d'installation d'accompagnement pour éviter d'endommager le produit
et les risques de blessures à vous-même ou les autres.
Notes:
For complete product description, features, and specifications, refer to product datasheet on the Vari-Lite web site
at www.philips.com/entertainmentlighting.
For power requirements, refer to “Current vs. Voltage” on page 6.
VL1100 LED Luminaires accept glass gobos only. Use of metal gobos will void the luminaire’s warranty.
Additional Documentation
For more information on installing DMX512 control systems, the following publication is available for purchase from the United States
Institute for Theatre Technology (USITT), “Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition” (ISBN:
9780955703522). USITT Contact Information:
USITT
315 South Crouse Avenue, Suite 200
Syracuse, New York 13210-1844 USA
Phone: 800-938-7488 or +1-315-463-6463
Fax: 866-398-7488 or +1-315-463-6525
Web Site: www.usitt.org
Customer Service
Our Goal
At Vari-Lite, we are committed to providing you the highest quality in customer service. Our comprehensive resources are available to help
your business succeed and ensure you get the full benefit of being a Vari-Lite customer. Whether your needs are telephone troubleshooting
assistance, product training or technical service, our full-time staff of experienced professionals are on-hand to provide support.
How to Reach Us
For assistance in your area, call the dealer from which your product was purchased.
or Contact an Authorized Service Center
or Contact the Vari-Lite Customer Service Department, 7am - 6pm CST Monday through Friday, at the following:
phone:1-877-VARI-LITE (1-877-827-4548) or +1-214-647-7880
Note: Performing maintenance procedures may void the product warranty. Refer to the Philips Entertainment Lighting Limited Warranty
card included in the product shipping package for more information. For all service and maintenance issues, please contact your local
Authorized VARILITE Dealer or Service Center.
Additional Resources
For additional resources and documentation on this product, please visit our website at www.philips.com/entertainmentlighting and follow
the Support link.
Document Number: 02.1602.0001
Version as of: 24 April 2017
VL1100 LED™ Luminaire QuickStart Guide
©2017 Vari-Lite All rights reserved.
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 2
Compliance and Safety Notices
Compliance
Safety Standards
We, Vari-Lite, 10911 Petal Street, Dallas, Texas 75238 declare under our responsibility for the products contained herein are in
conformity with the essential requirements of the following European Directives and Safety standards for United States and Canada.
EN 60589-2-17:1989+A2:1991 used in conjunction with 60598-1:2008/A11:2009
UL 1573 Issue: 2003/05/29 Ed: 4 Rev: 2016/12/22
CSA C22.2#166:2015 Ed.2
EMC Standards
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-
Lite system, service, and safety guidelines, may cause harmful interference to radio communications.
FCC 47CFR 15:2016
CENELEC EN 55015:2006/12/01
CES-005:2007/02/01
Safety Notice
It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation
before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product.
Safety symbols used throughout this manual are as follows:
GENERAL INFORMATION PERTAINING TO PROTECTION AGAINST ELECTRICAL SHOCK, FIRE, EXPOSURE TO EXCESSIVE
UV RADIATION, AND INJURY TO PERSONS CAN BE FOUND BELOW.
WARNING:
INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST FIRE
1. VARILITE luminaires have been designed for use with specific lamp types. The VL1100 LED Luminaire requires a certain type of
lamp (see “Replacement Items/Accessories” on page 8 for all lamp types). Installing another type or unapproved lamp may be
hazardous.
2. Luminaires may be mounted on any type of surface as long as mounting instructions are followed. See instructions detailed in this
manual.
3. Note distance requirement from combustible materials or illuminated objects for VARILITE luminaires.
WARNING:
INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST ELECTRICAL SHOCK
1. VARILITE luminaires are designed for dry locations only. Exposure to rain or moisture may damage luminaire.
2. Disconnect power before servicing any VARILITE equipment.
3. Servicing to be performed by qualified personnel only.
WARNING: Possibly hazardous optical radiation emitted from this product.
CAUTION advising of potential damage to product.
WARNING advising of potential injury or death to persons.
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
3 24 April 2017 02.1602.0001
WARNING:
RF INTERFERENCE
This is a Class B product. In a domestic environment this product may cause radio interference, in which case, the user may be required to
take adequate measures.
Notes de sécurité
Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les
renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les
avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
Les symboles de sécurité utilisés dans ce guide sont les suivants :
CETTE SECTION CONTIENT DES INFORMATIONS GÉNÉRALES POUR SE PROTÉGER CONTRE LES DÉCHARGES
ÉLECTRIQUES , LES INCENDIES, L’EXPOSITION EXCESSIVE AUX RAYONS UV ET TOUT AUTRE ACCIDENT POUVANT
ENTRAÎNER DES BLESSURES.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE LES INCENDIES
1. Les luminaires VARILITE ont été conçus pour être utilisés uniquement avec certaines type de lampes. Vérifier le type de lampe avant
de remplacer les lampes. L’installation d’un autre type de lampe peut poser un danger.
2. Les luminaires peuvent être fixés sur tout type de surface tant que les directives de montage sont respectées. Voir les explications
détaillées dans ce guide.
3. Vérifier la distance à respecter entre les matériaux combustibles ou les objets illuminés et les luminaires VARILITE.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE LES DÉCHARGES ÉLECTRIQUES
1. Les luminaires VARILITE sont conçus pour une utilisation au sec uniquement. Une exposition à la pluie et à l’humidité risque
d’endommager le luminaire.
2. Débrancher l’appareil avant de procéder à la révision de tout matériel VARILITE.
3. Les révisions doivent être effectuées uniquement par des personnes qualifiées.
AVERTISSEMENT:
DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAY-
ONS UV
1. Plusieurs luminaires VARILITE utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe.
2. L’utilisation des luminaires sans lentille ou blindage pose des risques. Tous blindages, lentilles ou écrans ultraviolet visiblement
endommagés au point que leur efficacité en est affectée doivent être remplacés, par exemple s’il y a des fissures ou de profondes
rayures.
AVERTISSEMENT:
INTERFÉRENCE RF
Cet appareil est de Classe B. Dans un environnement domestique, cet appareil peut causer des interférences radio, et si c’est le cas,
l’utilisateur peut avoir à prendre des mesures adéquates.
Other / Autre
Temperature / Température
Exterior surface temperature 25°C ambient / Température de surface extérieure 25°C ambiante
5 Minute / 5 Minutes: 37°C
Steady State / Régime permanent: 45°C
Light Source Replacement / Remplacement de sources lumineuses
The light source contained in this luminaire shall only be replaced by the manufacturer, service agent, or similar qualified person.
La source lumineuse contenue dans ce luminaire ne doit être remplacée que par le fabricant, l’agent de service ou une personne
qualifiée similaire.
ATTENTION Ce symbole annonce que l’appareil risque d’être endommagé.
AVERTISSEMENT Ce symbole annonce qu’il y a risque d’accident grave ou même fatal.
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 4
About The VL1100 LED Luminaire
Included Items
The following illustration shows all items included with the luminaire:
Figure 1: VL1100 LED Luminaire Included Items
Replacement Items/Accessories
The following optional and/or replacement items can be ordered directly from your Authorized VARILITE Dealer. When ordering, please
order by the Vari-Lite part number.
Note: Please Check with Authorized Vari*Lite Dealer for availability on accessories.
VL1100 LED Luminaire Part Number Variants
Vari-Lite Part No. Accessory
PCT1BE
AC Input Cable,
Neutrik® powerCON TRUE1 with Bare End (no connector), 1 Meter
PC1GTL208
AC Input Cable,
Neutrik® powerCON TRUE1 with Twist Lock (Male), 250V, 1 Meter
PCT1GP
AC Input Cable,
Neutrik® powerCON TRUE1 with Stage Pin (Male), 1 Meter
PCT1SB
AC Input Cable,
Neutrik® powerCON TRUE1 with Edison Male, 1 Meter
PEGASUS USB Upload Cable
22.9620.0194 Safety Cable Assembly
25.9661.0057 DMX Termination Connector Assembly
55.6840.0001 Truss Hook, Mega-Clamp, Round and Square
55.6841.0001 Truss Hook, Mega-Claw for 2” Round Tube
Part No. Model Model Description
20.1602.0001.01 VL1100 LED S VL1100 LED Low Color Temperature with Shutter
20.1602.0001.11 VL1100 LED I VL1100 LED Low Color Temperature with Iris
20.1602.0001.02 VL1100 LEDHP S VL1100 LED High Power with Shutter
20.1602.0001.12 VL1100 LEDHP I VL1100 LED High Power with Iris
Neutrik® powerCON TRUE1
AC Input Connector
Warranty Card
Product
Registration
Product Support
Sheet
QuickStart Guide
Included Items
(this document)
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
5 24 April 2017 02.1602.0001
Connecting Power and Data
Connecting Power
The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Current required depends on the AC supply voltage
and product model. Refer to “Current vs. Voltage” on page 6 for all models covered in this manual.
Note: The mating Neutrik® powerCON TRUE1 connector is supplied; however, you will need to purchase or construct a cable appropriate
for your application. Available power input cables is found in “Replacement Items/Accessories” on page 4.
Figure 2: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different connector. If required, install a new connector meeting
your requirements using the following wire color code reference:
WARNING: DO NOT connect to three-phase service in countries with 240 volt power. AVERTISSEMENT: NE PAS se connecter au
service en trois phases dans les pays avec puissance de 240 volts.
For single-phase power at 240 volts RMS:
Wire* Connection
Green/Yellow AC Ground
Blue AC Neutral
Brown AC Line
* International (Harmonized) Standard
Connection Pin
AC Neutral X
AC Line Y
Ground (Earth) G
AC Power Input
Input Panel Connections
Neutrik® powerCON TRUE1
AC Input Connector
Data In
Data Thru
3-Pole Neutrik
Locking Connector
for AC Input
EMPTY
PLUG
3-Pole Neutrik® powerCON TRUE1
for AC Input Power
X
Y
G
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 6
For three-phase power at 200 volts RMS:
WARNING: It is not recommended to power any VARILITE luminaire from a dimmer - even in 'NONDIM' mode. Dimmer and non-dim
modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time, but will
eventually result in power problems, luminaire mis-operation and/or failure and may void the luminaire’s warranty. AVERTISSEMENT: Il
n'est pas recommandé pour alimenter un luminaire VARILITE d'un gradateur - même en mode 'NONDIM. Modules de gradation et non
sombres ne sont pas des sources appropriées de pouvoir parce que leur production modifie la forme d'onde AC. Cela peut fonctionner
pendant une courte période, mais finira par entraîner des problèmes d'alimentation, luminaires mauvais fonctionnement et / ou l'échec et peut
annuler la garantie de l'appareil.
Current vs. Voltage
Table 1-1, VL1100 LED Luminaire - Current vs. Voltage (460W LED Source) provides the luminaire’s current draw at specific voltages.
Total Luminaire Current is calculated with the lamp on and all motors sequencing.
WARNING: It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not
overload circuits. AVERTISSEMENT: Il est de la responsibilité de l'utilisateur de protéger adéquatement la source d'alimentation avec une
taille correcte et le disjoncteur de type et surchargez pas les circuits.
Connecting Data
A maximum of 32 luminaires may be connected in any one DMX data link.
Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data
link path. Consult your console documentation for more information.
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of remaining luminaires in
link.
Connection Pin
Phase 1 X
Phase 2 Y
Ground (Earth) G
Table 1-1: VL1100 LED Luminaire - Current vs. Voltage (460W LED Source)
AC Voltage @ 60Hz Total Luminaire Current (Motor + LED Current)
100V 6.3A
110V 5.7A
120V 5.2A
130V 4.8A
200V 3.1A
210V 3.0A
220V 2.8A
230V 2.7A
240V 2.6A
X
Y
G
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
7 24 April 2017 02.1602.0001
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the
same DMX chain may not function properly without termination.)
Figure 3: Data Link
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement.
VL1100 LED™ Luminaire Channel Requirements*
*As set by the luminaire’s menu system.
DMX512 Channels Description
19 Channels LED I / LEDHP I DMX Map
27 Channels LED S / LEDHP S DMX Map
**DMX terminator required for last fixture on DMX line.
Data In
Termination**
Data Thru
AC In
AC In
AC In
Data Thru
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 8
Installation Procedures
Floor Mounting the Luminaire
All luminaires included in this manual are designed to sit directly on its base in a floor installation application. When used in this type of
application, be sure to leave enough space around the luminaire to allow proper, uninterrupted airflow for cooling and movement.
Hanging the Luminaire
The VL1100 LED™ Luminaire be hung horizontally or vertically from any structure designed to work with the type of load created by this
moving luminaire. The pan tube base provides two mounting holes for attaching truss hooks or other mounting hardware as required. Many
compatible truss hooks are available from different manufacturers for your particular needs. The Mega Claw Truss Hook, shown in the
example illustration below, can be ordered separately from Vari-Lite (refer to “Replacement Items/Accessories” on page 4).
To install truss hooks (if required):
Step 1. At pan tube base, attach two truss hooks as shown in Figure 4.
Step 2. Tighten hardware securely
Figure 4: Example VL1100 LED Luminaire Truss Hook Installation
To hang luminaire in truss:
Step 1. Lift luminaire into mounting position.
Step 2. Secure in place with truss hooks. Ensure truss hook hardware that locks hook in place (e.g. wing bolt)
is properly tightened and that luminaire is fully supported.
Step 3. Attach safety cable (sold separately, should attach with 2 locking carabiners) as follows:
a. Connect end of safety cable to safety mounting hole at one side of pan tube base.
b. Loop at least once around pipe and attach other end at second safety mounting hole.
Step 4. Connect power and data cables according to procedure outlined in “Connecting Power and Data” on
page 5
Hook Hardware
(not provided)
WARNING:
Attach truss
hooks securely.
Mega Claw Truss Hook
(not provided)
VL1100 LED
Pan Tube Base
Locking Carabiners
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
9 24 April 2017 02.1602.0001
Figure 5: Example VL1100 LED Luminaire Truss Hanging Installation
34.5”
(87.6cm)
17.5”
(44.5cm)
26.5”
(67.3cm)
26”
(66cm)
Safety Cable:
Recommended for all
hanging installations.
May be required by
local codes.
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 10
Menu Operation
LCD Display and Menu System
The VL1100 LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings:
Address – to set the DMX address
Setup – to change any modes
Configure – various parameter settings, set luminaire ID
Fixture – fixture status, recalibrate, reboot, software version, view fixtures hours, etc.
DMX – change the map, set address, invert pan/tilt
Manual – manual control of parameters
Test – test functions of parameters
The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple luminaires in a system, any
settings or changes would need to be made at each LCD Menu as desired.
Menu Controls
The menu system is controlled by an OK (Enter), ESC (Escape), and four Arrow () buttons. These buttons function are shown in
Figure 6.
Figure 6: Menu Control
LCD Display and Menu System Operation
The LCD Display Menu system consists of several categories. Use the menu buttons to access and make changes to menu items. When the
desired menu item is reached, press [Menu] button to display the menu options and to navigate and configure options as needed.
The menu system is controlled by four buttons. These buttons function as follows:
[Menu] button – Displays the menu, or if at first level, the current address. Can also enable menu to exit a menu level.
[Enter] button – Selects the current menu option or stores current data value
•[] Down arrow – Scrolls menu options upward or increases current data value.
•[] Up arrow – Scrolls menu options downward or decreases current data value.
To navigate and access menu settings/selections:
Step 1. Make sure unit is powered and turned on.
Step 2. Press [Menu] to display1st level functions.
Step 3. Scroll through the 1st level functions by pressing [] arrows.
Step 4. Once the desired function appears in the display, press OK [Enter] to access 2nd level functions.
Step 5. Use the [] arrows to scroll through 2nd level functions.
Step 6. Press [Enter] to access 3rd level functions. When the highest level for the function is reached, [] arrows can be pressed to
select a value or select a toggle activation such as ON/OFF.
Step 7. Press OK [Enter] to store the value or select an action.
Menu
Display
Up / Increase
Down / Decrease
LCD Display
Press to select current menu
option or current data value.
Press to
show menu,
or if at first
level, the
current
address.
Address
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
11 24 April 2017 02.1602.0001
For example, the Address function has one sub-level: DMX. This 2nd level menu allow access to a 3rd level, which is a value. The Address
function is a three-level menu.
Menu Default State
The menu displays default state during normal operation is to display the address. After 10 seconds of inactivity at the display, it will change
to this default state.
After 5 minutes of inactivity, the menu display will switch to its off state.
Program Starting Address
The DMX starting address is entered using the Menu Display. This address will be retained even if the power is removed.
Refer to your console operating instructions for specific information regarding its addressing requirements.
To program a DMX starting address:
Step 1. Press [Menu].
Step 2. Press [] arrows until Address appears. Press [Enter].
Step 3. DMX will appear. Press [Enter].
Step 4. Press [] arrows to enter starting address.
Step 5. Press [Enter] to set.
Program Starting Address Without Calibrating
It is possible to bypass the calibration sequence and go directly to the Menu Display programming in order to pre-program an address setting.
To program starting address without calibrating luminaire:
Step 1. While powering up luminaire, press and hold [Menu].
Step 2. Program address as described in “Program Starting Address” on page 11.
Step 3. Release when display reads ":"
The luminaire will require a reset to restore control.
1st Level
2nd Level 3rd Level
Address
DMX XXX
VARILITE - VL1100 LED LUMINAIRE QUICKSTART GUIDE
02.1602.0001 24 April 2017 12
Quick Reference DMX Map
The summary list for the Iris (I) and Shutter (S) 16-bit DMX maps are as indicated in VL1100 LED I / LED HP I - DMX Channel
Summary Listing and VL1100 LED S / LED HP S - DMX Channel Summary Listing.
Table 1-2: VL1100 LED I / LED HP I - DMX Channel Summary Listing
Table 1-3: VL1100 LED S / LED HP S - DMX Channel Summary Listing
DMX
Channel
Description
DMX
Channel
Description
1 Dimmer 11 Magenta
2, 3 Pan 12 Rotating Gobo
4, 5 Tilt 13, 14 Gobo Index
6 Edge 15 Beam
7 Zoom 16 Focus Time
8 Diffusion 17 Color Time
9 Blue 18 Beam Time
10 Amber 19 Control
DMX
Channel
Description
DMX
Channel
Description
1 Dimmer 13, 14 Gobo Index
2, 3 Pan 15, 16 Frame 1A, 1B
4, 5 Tilt 17, 18 Frame 2A, 2B
6 Edge 19, 20 Frame 3A, 3B
7 Zoom 21, 22 Frame 4A, 4B
8 Diffusion 23 Rotate Frame
9 Blue 24 Focus Time
10 Amber 25 Color Time
11 Magenta 26 Beam Time
12 Rotating Gobo 27 Control
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Vari-Lite VL1100 LEDHP Guide de démarrage rapide

Taper
Guide de démarrage rapide

dans d''autres langues