14
Operations
Pre-Run Inspection
1. Check all fittings and connectors for proper
assembly.
2. Check all hoses for leaks. Repair or replace any
damaged hoses.
3. Check power cord(s) for any damage. If damaged,
replace.
Equipment Set-up
1. Plug power cord from machine into properly
grounded wall outlet.
2. Turn vacuum motor switch on and off to make sure
there is electrical power at machine.
3. Using a clean container, fill the solution tank with
clean hot water. Do not use water over 130°F. Mix
in a non-foaming cleaning concentrate for use in
hot water extraction machines, following the manu-
facturer's instructions printed on container.
4. Connect priming hose to solution fitting on
machine. Turn on pump and run for 30 seconds or
until a steady flow of water is coming out of priming
hose. Turn off pump and disconnect priming hose.
5. Connect vacuum hose to machine. Slide the swivel
cuff over the outlet on the tank.
6. Connect the hose to your machine and wand. Pull
back the knurled collar on the quick disconnect
coupler and push onto the connection on the
chassis. To avoid leaks, check to be that a positive
connection was made.
NOTE: When using a powder cleaner, pre-mix with
hot water in a clean container before adding to the
solution tank.
7. Turn pump and vacuum switch(es) to the on
position.
Heater Operation
NOTE: Units with Heat Only
The solution fittings on the machine will become
extremely hot during operation. Allow sufficient
time to cool, or run solution through the machine
with the heater turned off before disconnecting or
performing any maintenance on the heater.
Les pièces de fixation de la machine deviennent
très chaudes pendant le fonctionnement. Prévoyez
suffisamment de temps pour refroidir, ou laissez
couler la solution à travers la machine avec le
réchauffeur éteint avant de débrancher ou
d'effectuer toute opération d'entretien sur le
réchauffeur.
1. Plug the two power cords into separate grounded
circuits. The heater draws 15 amps of current.
2. Turn the solution pump ON. Fully prime the
solution system before turning heater on.
3. Turn the heater switch on. The red light on the
heater switch will be on when the heater switch is
on. The red heater temperature light will be on
when the heater is active and will turn off when the
heater reaches maximum temperature.
On initial start-up the heater will take a few minutes to
reach operating temperature.
When turning the pump and heater OFF, make certain
that you turn the heater off FIRST.
86399050 Operators Manual - Dominator 500 PSI 13 gallon