9
CARE AND MAINTENANCE
TROUBLESHOOTING
WARRANTY
FCC STATEMENT:
Periodically clean the xture and diffuser using a mild, non-abrasive cleaner and soft cloth. When cleaning the xture, make sure the power is turned off. Do
not spray cleaner directly onto any part of the xture or LEDs.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Security light does not come on.
1. Light switch is off.
2. Fuse is blown or circuit breaker has tripped.
3. Fixture not properly wired to junction box.
4. Light is detected by sensor.
5. Motion sensor is pointed in the wrong direction.
6. Air temperature is about the same as a person’s body
temperature and the PIR sensor cannot “see” the person.
1. Turn light switch on.
2. Replace fuse. Turn the circuit breaker back on.
3. Discontinue use. Call an electrician.
4. Recheck at night.
5. Readjust motion sensor.
6. Decrease the DISTANCE control setting.
Light continuously cycles ON and
OFF (strobe effect).
1. Light sensor is triggered by reected light from the security
light itself.
2. Heat is being reected from other sources and may be
triggering sensor on and off.
1. Change the position of the light head. Aim light
away from the reecting surfaces.
2. Decrease the DISTANCE control setting.
Light turns on during daylight hours. 1. Light may be installed in shadows/dark area.
2. The MINUTES control knob is set to MOTION TEST.
1. Light is operating as it was designed. Use
manual override if necessary. Or set to “Switch
Control.”
2. Set the MINUTES control knob somewhere
between 1 and 10.
Light comes on for no apparent
reason.
1. Sensor may be triggered by a small animal or passing car.
2. Hot air (dryer vent, car exhaust, etc.) may be triggering the
sensor.
1. Decrease the DISTANCE control setting as
necessary.
2. Increase the DISTANCE control setting as
necessary.
Light stays on continuously at night.
1. Motion sensor may be picking up a continuous ow of
warm air from an air vent, dryer vent, or heat reecting off a
surface.
2. Interference generated from transformers, uorescent light
xtures, or electric motors are connected to the same circuit.
1. Reposition the motion sensor.
2. Install the light on a circuit without transformers,
uorescent light xtures or electric motors
connected to the circuit.
Light ashes on for 20 seconds at a
time, day or night. The MINUTES control knob is set to MOTION TEST. Set the MINUTES control knob somewhere
between 1 and 10.
Light head slips down. Star knobs are loose. Reposition light head and tighten star knobs.
Light output is too bright or too low. Brightness button was pressed too many times. Press the low/high beam control button once to
change the high/low beam.
Light output is too warm,neutral,or
cool. Press white light selection button to desired light temp. Press white light selection button to change to a
warmer, more neutral or cooler white light selection.
The manufacturer warrants this lighting xture to be free from defects in materials and workmanship for a period of (10) years from the date of original
purchase by the consumer. The xture is not warrantied for use in a commercial or retail application. The warranty is limited to use in a residential
environment. We will repair or replace (at our option) the unit in the original color and style if available, or in a similar color and style if the original item has
been discontinued, without charge. Defective units must be properly packed and returned to the manufacturer with a letter of explanation and your original
purchase receipt showing date of purchase. Call 1-800-291-8838 to obtain a return authorization number and an address where to ship your defective
product. Note: C.O.D. shipments will NOT be accepted. The liability of the manufacturer is in any case limited to replacement of the defective light xture
product. The manufacturer will not be liable for any other loss, damage, labor costs or injury which is caused by the product. This limitation upon the liability
of the manufacturer includes any loss, damage, labor costs or injury which is (I) to person or property or otherwise; (II) incidental or consequential in nature;
(III) based upon theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale, use, or repair of
the product. This warranty gives you specic rights, and you may also have other rights which vary from state to state. For bulb warranty, please see box.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Warning: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1)
Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit different from that of the receiver. 4) Consult the
dealer or an experienced radio/TV technician for help.
Address: 1400 E Business Center Drive, Ste. 108, Mount Prospect IL 60056, USA
Telephone number: 1-800-291-8838
REPLACEMENT PARTS LIST
Hardware Kit #
ZH-SE1356-F01-WH3
Printed in China
Before doing any work on the xture, shut off power supply at the circuit breaker panel to avoid electrical shock.