Thermo Fisher Scientific RapidFinder Poultry ID Kit Mode d'emploi

Taper
Mode d'emploi
For testing of Food and Environmental samples only.
RapidFinder Poultry ID Kit
USER GUIDE
Real-time PCR detection of poultry DNA in food and feed
samples
for use with:
Applied Biosystems QuantStudio 5 RealTime PCR Instrument with Thermo
Scientific RapidFinder Analysis Software v1.2 or later
Applied Biosystems 7500 Fast RealTime PCR Instrument with Applied
Biosystems RapidFinder Express Software v2.0 or later
Catalog Number A24397
Publication Number MAN0009929
Revision D.0
Oxoid Limited | Wade Road | Basingstoke, Hampshire UK RG24 8PW
For descriptions of symbols on product labels or product documents, go to thermofisher.com/symbols-definition.
The information in this guide is subject to change without notice.
DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, THERMO FISHER SCIENTIFIC INC. AND/OR ITS AFFILIATE(S) WILL NOT BE
LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR
ARISING FROM THIS DOCUMENT, INCLUDING YOUR USE OF IT.
Revision history: Pub. No. MAN0009929
Revision Date Description
D.0 8 July 2021 Added ISO certification
Added QuantStudio 5 RealTime PCR Instrument with Thermo
Scientific RapidFinder Analysis Software v1.2 or later
C.0 7 August 2020 Updated the template. Minor edits throughout.
B.0 March 2015 Updated specificity table
Corrected volume of Positive Control
Corrected quencher to NFQ-MGB
A.0 March 2014 New document
Trademarks: All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. TaqMan is a
registered trademark of Roche Molecular Systems, Inc., used under permission and license. Imegen agro is a trademark of Instituto de
Medicina Genómica SL.
©2021 Thermo Fisher Scientific Inc. All rights reserved.
Contents
CHAPTER 1 Product information .................................................. 5
Product description ............................................................. 5
Kit contents and storage ......................................................... 5
Materials required but not provided ................................................ 6
CHAPTER 2 Methods ............................................................... 7
Input DNA requirements ......................................................... 7
Determine the number of reactions, then thaw the reagents .......................... 7
Set up the PCR reactions ........................................................ 7
Set up and run the real-time PCR instrument ....................................... 8
Analyze results .................................................................. 8
Interpretation of results .......................................................... 9
Quantitative analysis ............................................................. 9
APPENDIX A Troubleshooting .................................................... 11
APPENDIX B Supplemental information ........................................ 13
Kit sensitivity and specificity ..................................................... 13
UNEEN ISO 9001 certification ................................................... 14
UNEEN ISO 14001 certification ................................................. 14
APPENDIX C Good laboratory practices for PCR .............................. 15
Plate layout suggestions ........................................................ 15
APPENDIX D Safety ............................................................... 16
Chemical safety ................................................................ 17
Biological hazard safety ......................................................... 18
RapidFinder Poultry ID Kit User Guide 3
APPENDIX E Documentation and support ...................................... 19
Food Safety support ............................................................ 19
Customer and technical support ................................................. 19
Related documentation ......................................................... 20
Limited product warranty ........................................................ 20
Contents
4RapidFinder Poultry ID Kit User Guide
Product information
Product description
Identification of meat species present in food samples is an essential step for verification of origin
and traceability of raw materials, as well as for quality control of handling and cleaning processes in
production lines. The Thermo Scientific RapidFinder Poultry ID Kit enables real-time PCR detection
of poultry DNA that is present in food and feed samples. The kit detects blends containing ≥0.01% of
poultry DNA.
The kit includes:
All reagents necessary for the real‐time PCR reaction—specific FAM-labeled probe and primers
for poultry mitochondrial DNA, DNA polymerase enzyme, and other buer components.
An internal positive control (IPC)—VIC-labeled probe, primers, and template, to monitor for PCR
inhibition.
A Positive Control, to confirm poultry DNA detection.
Unknown samples and control samples are provided by the investigator.
Kit contents and storage
Table 1 RapidFinder Poultry ID Kit (Cat. No. A24397)
Component Amount (48 reactions) Storage[1]
Poultry Master Mix (yellow pad) 360 µL –20°C
General Master Mix (white pad) 600 µL 4°C
Positive Control (yellow cap) 60 µL –20°C
[1] See the expiration date on the box.
1
RapidFinder Poultry ID Kit User Guide 5
Materials required but not provided
Unless otherwise indicated, all materials are available through the Thermo Fisher Microbiology ordering
process. MLS: Fisher Scientific (fisherscientific.com) or other major laboratory supplier.
Catalog numbers that appear as links open the web pages for those products.
Item Source
Real-time PCR instrument, one of the following:
Applied Biosystems QuantStudio 5 RealTime PCR System
RapidFinder Analysis Software v1.2 or later
Contact your local microbiology
sales representative.
Applied Biosystems 7500 Fast Real-Time PCR System
RapidFinder Express Software v.2.0 or later
Equipment
Adjustable micropipettors (10 µL, 20 µL, 200 µL) Available through the Thermo
Fisher Microbiology ordering
process. See thermofisher.com/
plastics for more information.
Benchtop microcentrifuge with adaptors for PCR plates and/or tubes
Laboratory mixer (Vortex mixer or equivalent)
Optical reaction plates and covers, or optical PCR tubes and caps
MicroAmp Fast Optical 96-Well Reaction Plate, 0.1 mL 4346907
MicroAmp Optical Adhesive Film, 100 covers 4311971
MicroAmp Fast 8-Tube Strip, 0.1 mL
(See below for caps.)
4358293
MicroAmp Optical 8-Cap Strips 4323032
Other plastics and consumables
Aerosol-resistant pipette tips Available through the Thermo
Fisher Microbiology ordering
process. See thermofisher.com/
plastics for more information.
1.5-mL nuclease-free microcentrifuge tubes
Powder-free disposable gloves
Reagents
Nuclease-free water (not DEPC-Treated) AM9938
Recommended kits for DNA isolation, one of the following:
GMO Extraction Kit 4466336
For high-throughput isolation:
Lysis Buer 1 + RNase for Food ID
PrepSEQ Nucleic Acid Extraction Kit
A24401
4428176, 4480466
Chapter 1 Product information
Materials required but not provided
1
6RapidFinder Poultry ID Kit User Guide
Methods
Input DNA requirements
Prepare the DNA sample with a method that allows processing of 10–20 g of food sample.
For low-throughput, manual processing, use the GMO Extraction Kit.
For high-throughput, automated processing, use Lysis Buer 1 + RNase for Food ID and the
PrepSEQ Nucleic Acid Extraction Kit with the KingFisher mL Magnetic Particle Processor.
Prepare at least one mock-purified sample as a negative extraction control, processed with the
same DNA isolation method that is used for test samples.
Dilute the final DNA sample to 10 ng/µL for the PCR.
Determine the number of reactions, then thaw the reagents
1. Plan to include the following reactions:
Single reactions for each test sample.
Single control reactions.
Positive Control (included in the kit).
Negative extraction control (mock-purified samples).
No-template control reactions; use nuclease-free water in place of sample DNA.
2. Thaw all reagents, vortex to mix thoroughly, then place on ice.
Set up the PCR reactions
1. Combine the following components for the number of reactions required plus 10% overage.
Component Volume per reaction
Poultry Master Mix (yellow pad) 7.5 µL
General Master Mix (white pad) 12.5 µL
2. Mix thoroughly by vortexing, then distribute 20 µL to each reaction well or tube.
3. Add 5 µL of DNA sample (10 ng/µL), mock-purified sample (negative extraction control),
nuclease-free water (no-template control), or Positive Control to the appropriate wells.
4. Seal each plate or tube, mix, then centrifuge briefly to bring the contents to the bottom.
2
RapidFinder Poultry ID Kit User Guide 7
Set up and run the real-time PCR instrument
See the appropriate instrument user guide for detailed instructions to set up and run the real-time PCR
instrument.
1. Set up the real-time PCR instrument using the following settings:
Reaction volume: 25 µL
Passive reference dye: ROX dye included
TaqMan probe reporter dyes and quenchers:
Target Reporter Quencher
Poultry DNA FAM dye NFQ-MGB
IPC VIC dye NFQ-MGB
Thermal cycler settings:
Setting Stage 1
Enzyme activation
Stage 2
PCR
Number of cycles 1 (Hold) 36
Denature Anneal/extend[1]
Temperature 95°C 95°C 60°C
Time 10 minutes 15 seconds 1 minute
[1] Fluorescence is acquired during the annealing/extension stage.
2. Load the reactions, run the thermal cycler program and collect real-time amplification data.
Analyze results
The general process for analyzing results is described in this section. The details of data analysis
depend on the real-time PCR instrument that you use; see the appropriate user guide for instructions
on how to analyze your data.
1. View the amplification plots for all reactions to make sure that they appear normal.
2. Use the Auto instrument setting to set the baseline.
3. Set the FAM and VIC threshold to 0.1.
Chapter 2 Methods
Set up and run the real-time PCR instrument
2
8RapidFinder Poultry ID Kit User Guide
4. Check that the results obtained in all control wells are as expected. For unexpected control results,
see Appendix A, “Troubleshooting”.
Reaction type FAM channel
(Poultry DNA)
VIC channel
(IPC)[1]
Positive Control + +
Negative extraction control +
No-template control +
[1] In all reactions, the Ct of the IPC should be similar to the Ct of the Positive Control.
5. Establish the positive cut-o value for the test samples and assign results:
Ct (cut-o) = Ct (Positive Control) + 3.32
Sample Ct value Sample result
Ct > Ct (cut-o) Negative
Ct ≤ Ct (cut-o) Positive[1]
[1] For fresh or minimally processed meat samples, the cut-off value corresponds to approximately 0.01% poultry DNA, when the
DNA sample concentration is 10 ng/µL.
Interpretation of results
Interpret unknown sample results according to the following table.
FAM channel
(Poultry DNA)
VIC channel
(IPC)
Interpretation
+ Poultry DNA not detected.
+ + Poultry DNA detected.
Invalid result. See Appendix A, “Troubleshooting”.
+ This result is expected in reactions that have
a strong FAM signal. See Appendix A,
“Troubleshooting”.
Quantitative analysis
For samples with positive results, the percentage of poultry DNA with respect to total animal DNA
can be quantified using the RapidFinder Poultry ID Kit in combination with the RapidFinder Quant
Multi-Meat Set (Cat. No. A24399).
The RapidFinder Quant Multi-Meat Set includes the Multi-Meat Standard, a plasmid DNA quantitation
standard containing individual species-specific DNA targets and a highly conserved animal-specific
mitochondrial genomic region (total animal DNA target). The kit also includes a TaqMan assay for the
total animal DNA target. Both species-specific and total animal DNA present in each sample can be
Chapter 2 Methods
Interpretation of results 2
RapidFinder Poultry ID Kit User Guide 9
quantified relative to the Multi-Meat Standard using primer and probe sets from both kits. For detailed
instructions, see the RapidFinder Quant Multi-Meat Set User Guide (Pub. No. MAN0009930).
Note: The Positive Control included in the RapidFinder Poultry ID Kit is not intended for use as a
quantitation standard.
Chapter 2 Methods
Quantitative analysis
2
10 RapidFinder Poultry ID Kit User Guide
Troubleshooting
Observation Possible cause Recommended action
In the Positive Control wells,
no target-specific and no IPC
signals are detected.
PCR amplification failure. Check that the thermal cycler settings and
amplification program are correct.
In the negative extraction
control wells, target-specific
and IPC signals are detected.
Contamination during the DNA
extraction procedure.
Contamination may be due to errors in
sample handling, reagent contamination, or
environmental contamination.
Check that the DNA extraction protocol
was performed correctly.
Take care to avoid contamination during
sample homogenization: decontaminate
grinding equipment or homogenizer with
10% bleach or DNAZap Solutions (Cat.
No. AM9890).
Decontaminate benchtop surfaces and
other equipment where the DNA
extraction process is performed with
10% bleach or DNAZap Solutions.
If necessary, use fresh reagents and
repeat the DNA extraction.
In the no-template control
wells, target-specific and IPC
signals are detected.
Contamination of the PCR. Contamination may be due to errors in
sample handling, reagent contamination, or
environmental contamination.
Decontaminate benchtop surfaces and
other equipment where PCR is performed
with 10% bleach or DNAZap Solutions
(Cat. No. AM9890).
Use fresh reagents and repeat the PCR.
Set up the Positive Control PCR reactions
last to avoid cross-contamination.
In unknown wells, no IPC
signal is detected, but target-
specific signal is detected.
A high copy number of
target DNA exists in samples,
resulting in preferential
amplification of the target-
specific DNA.
No action is required. The result is considered
positive.
In unknown wells, no IPC
or target-specific signal is
detected.
Excess sample DNA in
the PCR; the recommended
maximum is 250 ng.
Repeat the PCR with the correct amount of
DNA. If DNA quantification is not possible,
dilute the DNA sample.
A
RapidFinder Poultry ID Kit User Guide 11
Observation Possible cause Recommended action
In unknown wells, no IPC
or target-specific signal is
detected.
(continued)
PCR inhibitors in the sample
DNA.
Repeat the DNA extraction. If the problem
persists, contact Technical Support.
Appendix A Troubleshooting
Quantitative analysis
A
12 RapidFinder Poultry ID Kit User Guide
Supplemental information
Kit sensitivity and specificity
The detection limit was calculated with standard samples consisting of mixtures of raw poultry meat
and other species. The RapidFinder Poultry ID Kit can detect blends with as little as 0.01% (w/w) of
poultry meat. The limit of detection in processed samples varies depending upon the composition and
food processing.
The kit specificity was tested by comparison of the probe and primer sequences with the NCBI
database, and it was also experimentally tested on a collection of reference DNAs, with the following
results.
Note: The primers and probes in this kit have been designed to detect any kind of bird species. It is
more common to detect poultry meat in food samples, but it is possible to use this kit to detect bird
species DNA in general.
Meat species Result
Sheep Not detected
Goat Not detected
Horse Not detected
Beef Not detected
Pork Not detected
Bualo Not detected
Deer Not detected
Chicken Detected
Turkey Detected
Duck Detected
Ostrich Detected
Goose Detected
Human Not detected
Fish Not detected
B
RapidFinder Poultry ID Kit User Guide 13
UNEEN ISO 9001 certification
Imegen is certified against the standard UNE-EN ISO 9001:2015 "Quality management systems" for the
design, development, manufacture, and commercialization of kits for genetic analysis.
UNEEN ISO 14001 certification
Imegen is certified against the standard UNE-EN ISO 14001:2015 “Environmental Management
Systems” for the design, development, manufacture, and commercialization of kits for genetic analysis.
Appendix B Supplemental information
UNEEN ISO 9001 certification
B
14 RapidFinder Poultry ID Kit User Guide
Good laboratory practices for PCR
To avoid amplicon contamination of samples, follow these guidelines when preparing or handling
samples for PCR amplification:
Wear clean gloves and a clean lab coat (not previously worn while handling amplified products or
used during sample preparation).
Change gloves whenever you suspect that they are contaminated.
Maintain separate areas and dedicated equipment and supplies for:
Sample preparation and reaction setup.
Amplification and analysis of products.
Do not bring amplified products into the reaction setup area.
Open and close all sample tubes carefully. Avoid splashing or spraying samples.
Keep reactions and components capped as much as possible.
Use a positive-displacement pipettor or aerosol-resistant barrier pipette tips.
Do not open reaction tubes after PCR.
Do not autoclave reaction tubes after PCR.
Clean lab benches and equipment periodically with 10% bleach solution or DNAZap Solutions
(Cat. No. AM9890). After cleaning with bleach we recommend a rinse with an ethanol solution
because bleach will rust stainless steel.
For additional information, refer to EN ISO 22174:2005 or www.thermofisher.com/us/en/home/life-
science/pcr/real-time-learning-center/real-time-pcr-basics.html.
Plate layout suggestions
Separate dierent targets by a row if enough space is available.
Put at least one well between unknown samples and controls if possible.
Separate negative and positive controls by one well if possible.
Place replicates of one sample for the same target next to each other.
Start with the unknown samples and put controls at the end of the row or column.
Put positive controls in one of the outer rows or columns if possible.
Consider that caps for PCR tubes come in strips of 8 or 12.
C
RapidFinder Poultry ID Kit User Guide 15
Safety
WARNING! GENERAL SAFETY. Using this product in a manner not specified in the user
documentation may result in personal injury or damage to the instrument or device. Ensure that
anyone using this product has received instructions in general safety practices for laboratories and
the safety information provided in this document.
·Before using an instrument or device, read and understand the safety information provided in the
user documentation provided by the manufacturer of the instrument or device.
·Before handling chemicals, read and understand all applicable Safety Data Sheets (SDSs) and use
appropriate personal protective equipment (gloves, gowns, eye protection, and so on). To obtain
SDSs, see the “Documentation and Support” section in this document.
D
16 RapidFinder Poultry ID Kit User Guide
Chemical safety
WARNING! GENERAL CHEMICAL HANDLING. To minimize hazards, ensure laboratory personnel
read and practice the general safety guidelines for chemical usage, storage, and waste provided
below. Consult the relevant SDS for specific precautions and instructions:
·Read and understand the Safety Data Sheets (SDSs) provided by the chemical manufacturer
before you store, handle, or work with any chemicals or hazardous materials. To obtain SDSs, see
the "Documentation and Support" section in this document.
·Minimize contact with chemicals. Wear appropriate personal protective equipment when handling
chemicals (for example, safety glasses, gloves, or protective clothing).
·Minimize the inhalation of chemicals. Do not leave chemical containers open. Use only with
sucient ventilation (for example, fume hood).
·Check regularly for chemical leaks or spills. If a leak or spill occurs, follow the manufacturer
cleanup procedures as recommended in the SDS.
·Handle chemical wastes in a fume hood.
·Ensure use of primary and secondary waste containers. (A primary waste container holds the
immediate waste. A secondary container contains spills or leaks from the primary container.
Both containers must be compatible with the waste material and meet federal, state, and local
requirements for container storage.)
·After emptying a waste container, seal it with the cap provided.
·Characterize (by analysis if needed) the waste generated by the particular applications, reagents,
and substrates used in your laboratory.
·Ensure that the waste is stored, transferred, transported, and disposed of according to all local,
state/provincial, and/or national regulations.
·IMPORTANT! Radioactive or biohazardous materials may require special handling, and disposal
limitations may apply.
AVERTISSEMENT ! PRÉCAUTIONS GÉNÉRALES EN CAS DE MANIPULATION DE PRODUITS
CHIMIQUES. Pour minimiser les risques, veiller à ce que le personnel du laboratoire lise attentive‐
ment et mette en œuvre les consignes de sécurité générales relatives à l’utilisation et au stockage
des produits chimiques et à la gestion des déchets qui en découlent, décrites ci-dessous. Consulter
également la FDS appropriée pour connaître les précautions et instructions particulières à respecter :
·Lire et comprendre les fiches de données de sécurité (FDS) fournies par le fabricant avant de
stocker, de manipuler ou d’utiliser les matériaux dangereux ou les produits chimiques. Pour obtenir
les FDS, se reporter à la section « Documentation et support » du présent document.
·Limiter les contacts avec les produits chimiques. Porter des équipements de protection appropriés
lors de la manipulation des produits chimiques (par exemple : lunettes de sûreté, gants ou vête‐
ments de protection).
·Limiter l’inhalation des produits chimiques. Ne pas laisser les récipients de produits chimiques
ouverts. Ils ne doivent être utilisés qu’avec une ventilation adéquate (par exemple, sorbonne).
·Vérifier régulièrement l’absence de fuite ou d’écoulement des produits chimiques. En cas de fuite
ou d’écoulement d’un produit, respecter les directives de nettoyage du fabricant recommandées
dans la FDS.
·Manipuler les déchets chimiques dans une sorbonne.
Appendix D Safety
Chemical safety D
RapidFinder Poultry ID Kit User Guide 17
·Veiller à utiliser des récipients à déchets primaire et secondaire. (Le récipient primaire contient les
déchets immédiats, le récipient secondaire contient les fuites et les écoulements du récipient pri‐
maire. Les deux récipients doivent être compatibles avec les matériaux mis au rebut et conformes
aux exigences locales, nationales et communautaires en matière de confinement des récipients.)
·Une fois le récipient à déchets vidé, il doit être refermé hermétiquement avec le couvercle fourni.
·Caractériser (par une analyse si nécessaire) les déchets générés par les applications, les réactifs et
les substrats particuliers utilisés dans le laboratoire.
·Vérifier que les déchets sont convenablement stockés, transférés, transportés et éliminés en res‐
pectant toutes les réglementations locales, nationales et/ou communautaires en vigueur.
·IMPORTANT ! Les matériaux représentant un danger biologique ou radioactif exigent parfois une
manipulation spéciale, et des limitations peuvent s’appliquer à leur élimination.
WARNING! HAZARDOUS WASTE (from instruments). Waste produced by the instrument is
potentially hazardous. Follow the guidelines noted in the preceding General Chemical Handling
warning.
WARNING! 4L Reagent and Waste Bottle Safety. Four-liter reagent and waste bottles can crack
and leak. Each 4-liter bottle should be secured in a low-density polyethylene safety container with the
cover fastened and the handles locked in the upright position.
Biological hazard safety
WARNING! Potential Biohazard. Depending on the samples used on this instrument, the surface
may be considered a biohazard. Use appropriate decontamination methods when working with
biohazards.
WARNING! BIOHAZARD. Biological samples such as tissues, body fluids, infectious agents,
and blood of humans and other animals have the potential to transmit infectious diseases.
Conduct all work in properly equipped facilities with the appropriate safety equipment (for example,
physical containment devices). Safety equipment can also include items for personal protection,
such as gloves, coats, gowns, shoe covers, boots, respirators, face shields, safety glasses, or
goggles. Individuals should be trained according to applicable regulatory and company/ institution
requirements before working with potentially biohazardous materials. Follow all applicable local,
state/provincial, and/or national regulations. The following references provide general guidelines when
handling biological samples in laboratory environment.
·U.S. Department of Health and Human Services, Biosafety in Microbiological and Biomedical
Laboratories (BMBL), 6th Edition, HHS Publication No. (CDC) 300859, Revised June 2020
https://www.cdc.gov/labs/pdf/CDC-BiosafetymicrobiologicalBiomedicalLaboratories-2020-
P.pdf
·Laboratory biosafety manual, fourth edition. Geneva: World Health Organization; 2020 (Laboratory
biosafety manual, fourth edition and associated monographs)
www.who.int/publications/i/item/9789240011311
Appendix D Safety
Biological hazard safety
D
18 RapidFinder Poultry ID Kit User Guide
Documentation and support
Food Safety support
Website: thermoscientific.com/foodmicro or thermofisher.com/foodsafety
Imegen website for Certificates of Analysis and other product documentation: https://
portal.imegen.es/en/certificate-of-analysis/
Support email:
Europe, Middle East, Africa: microbiology.techsupport.uk@thermofisher.com
North America: microbiology@thermofisher.com
Phone: Visit thermofisher.com/support, select the link for phone support, then select the appropriate
country from the dropdown list.
Customer and technical support
Visit thermofisher.com/support for the latest service and support information.
Worldwide contact telephone numbers
Product support information
Product FAQs
Software, patches, and updates
Training for many applications and instruments
Order and web support
Product documentation
User guides, manuals, and protocols
Certificates of Analysis
Safety Data Sheets (SDSs; also known as MSDSs)
Note: For SDSs for reagents and chemicals from other manufacturers, contact the
manufacturer.
E
RapidFinder Poultry ID Kit User Guide 19
Related documentation
Document Publication number
RapidFinder Express Software Quick Reference 4480999
Thermo Scientific KingFisher Flex User Manual N07669
QuantStudio 3 and 5 RealTime PCR Systems Installation, Use, and
Maintenance Guide MAN0010407
Applied Biosystems 7300/7500/7500 Fast Real-Time PCR System
Installation and Maintenance Guide 4378657
Applied Biosystems 7500/7500 Fast Real‐Time PCR System: Maintenance
Guide 4387777
SimpliAmp Thermal Cycler User Guide MAN0009889
SimpliAmp Thermal Cycler Installation and Operation Quick Reference A24827
PCR Starter Kit for 96-well blocks, 0.2 mL, User Guide A24829
Limited product warranty
Life Technologies Corporation and/or its aliate(s) warrant their products as set forth in the
Life Technologies' General Terms and Conditions of Sale at www.thermofisher.com/us/en/home/
global/terms-and-conditions.html. If you have any questions, please contact Life Technologies at
www.thermofisher.com/support.
Appendix E Documentation and support
Related documentation
E
20 RapidFinder Poultry ID Kit User Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Thermo Fisher Scientific RapidFinder Poultry ID Kit Mode d'emploi

Taper
Mode d'emploi