Kichler Lighting 9920DCO Manuel utilisateur

Taper
Manuel utilisateur
1) Turn off power.
2) Slip xture over post and mark position of mounting holes in post.
3) Remove xture from post.
4) Drill 3/16” dia holes in post at positions marked .
5) If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector. (Not provided). Never connect
ground wire to black or white power supply wires.
6) Make wire connections (connectors not provided). Reference chart below
for correct connections and wire accordingly.
7) Slip xture over post and secure in place using provided screws. Screws
should slip into holes drilled in post.
8) Insert recommended bulb.
9) Set roof on top of xture passing threaded studs on roof through holes on
xture. Screw nials onto threaded studs.
1) Couper le courant électrique.
2) Passer le luminaire par dessus le support et marquer un repère pour les
trous de montage sur le support.
3) Enlever le luminaire du support.
4) Percer des trous de 1/8 po sur chacun des repères du support.
5) Si luminaire est fourni a vec un l de mise à la terre, le connecter à la boîte
de sortie de courant de mise à la terre avec un serre-ls (non fourni). Ne
jamais connecter un l de mise à la terre aux ls d’alimentation noir ou
blanc.
6) Connecter les ls (connecteurs non fournis). Se porter au tableau ci-dessous
pour faire les connexions.
7) Faire glisser le luminaire sur le support et xer à l’aide des vis. Les vis
doivent s’ajuster correctement dans les trous du support.
8) Installer l’ampoule recommandée.
9) Installer le chapeau sur le luminaire en introduisant les goujons dans les
trous situés sur le luminaire. Visser les ornements sur les boules.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
FIXTURE
LUMINAIRE
Date Issued: 12/15/06 IS-9920-CB
FINIAL
ORNEMENT
ROOF
CHAPEAU
THREADED
STUD
GOUJON
SCREW
VIS
POST
SUPPORT
INSTRUCTIONS
For Assembling and Installing Fixtures
in Canada
Pour L’assemblage et L’installation Au Canada
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre