Whirlpool RH2330XJQ3 Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
24"(58 CM), 30"(76.2 CM), 36"(91.4 CM)
RANGEHOOD
HOTTED'ASPIRATIONDE
24"(58 CM), 30"(76,2 CM), 36"(91,4 CM)
Table of Contents/Table des matieres ............................................................................. 2
........... /
IMPORTANT: READ AND SAVE THESE _NSTRUCTJONS.
FOR RES_DENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER DES _NSTRUCT_ONS,
POUR UTJLISAT_ON RE_SIDENT_ELLE UN_QUEMENT,
99043751A/W10112419A
TABLEOF CONTENTS
RANGE HOOD SAFETY ................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 4
Tools and Parts ............................................................................ 4
Location Requirements ................................................................ 4
Venting Requirements .................................................................. 5
Electrical Requirements ............................................................... 7
INSTALLATION INSTRUCTIONS .................................................. 7
Prepare Location .......................................................................... 7
Install Range Hood ....................................................................... 9
Make Electrical Connection ....................................................... 10
Complete Installation ................................................................. 10
RANGE HOOD USE ...................................................................... 10
Range Hood Controls ................................................................ 10
RANGE HOOD CARE ................................................................... 11
Cleaning ...................................................................................... 11
ASSISTANCE OR SERVICE ......................................................... 11
In the U.S.A ................................................................................ 11
In Canada ................................................................................... 11
WAR RAN TY .................................................................................. 12
TABLEDESMATIERES
SI_CURITE DE LA HOTTE DE CUlSINII_RE ............................... 13
EXIGENCES D'INSTALLATION ................................................... 15
Outillage et pieces ...................................................................... 15
Exigences d'emplacement ......................................................... 15
Exigences concernant I'evacuation ........................................... 16
Specifications electriques .......................................................... 17
INSTRUCTIONS D'INSTALLATION ............................................. 18
Preparation de I'emplacement ................................................... 18
Installation de la hotte ................................................................ 20
Raccordement electrique ........................................................... 21
Achever I'installation .................................................................. 21
UTILISATION DE LA HOTTE DE CUlSINIERE ........................... 21
Commandes de la hotte de cuisiniere ....................................... 22
ENTRETIEN DE LA HOTTE .......................................................... 22
Nettoyage ................................................................................... 22
ASSISTANCE OU SERVICE ......................................................... 22
GARANTI E ..................................................................................... 23
RANGE HOOD SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT SAFETY mNSTRUCTIONS
WARNmNG: TO REDUCE THE RiSK OF FIRE, ELECTRIC
SHOCK, OR iNJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. Hfyou have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and Iock the service disconnecting means to
prevent power from being switched on accidentatIy. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
HnstaiIation work and electrica! wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fueI
burning equipment to prevent backdrafting. FoIIow the
heating equipment manufacturer's guideline and safety
standards such as those published by the NationaI Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the Iocal code authorities.
When cutting or drilling into walI or ceiling; do not damage
electricaI wiring and other utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to propedy exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within wails or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RHSKOF FHRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RiSK OF A RANGE TOP
GREASE FIRE:
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spiIIovers that may
ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
fiambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flamb6).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RiSK OF iNJURY TO
PERSONS iN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING: _
SMOTHER FLAMES with a c!ose fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. Hfthe flames do not go out
immediately, EVACUATE AND CALL THE FiRE
DEPARTMENT.
NEVER PHCK UP A FLAMHNG PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels
a violent steam explosion will result.
Use an extinguisher ONLY if:
- You know you have a class ABC extinguisher, and you
already know how to operate it.
- The fire is smaII and contained in the area where it
started.
- The fire department is being called.
- You can fight the fire with your back to an exit.
aBased on "Kitchen Fire Safety Tips" published by NFPA.
,, WARNING: To reduce the risk of fire or eIectricaI shock,
do not use this fan with any solid-state speed control
device.
SAVE THESE iNSTRUCTiONS
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Drill
11/4"(3 cm) drill bit
1/8"(3 mm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
For vented installations, you also need:
Saber or keyhole saw
Compass or 61/4'' (15.9 cm) circle template (if using a 31/4'' x
10" (8.3 x 25.4 cm) rectangular vent to 6" (15.2 cm) round
vent transition)
Vent clamps
Metal snips
Parts supplied
Remove parts from package. Check that all parts are included.
4 - #10 x %" type A truss phil screws
Filter
31/4'' x 10" (8.3 x 25.4 cm) vent connector/damper
2 - #8B sheet metal screws
Parts needed
For direct wire installation
UL listed or CSA approved 1/2"(12.5 mm) strain relief
75-watt max. incandescent light bulb
Power supply cable (if needed, for direct wire installation)
For power supply cord installation
UL Listed Power Supply Cord Connection Kit marked for
range hood use.
75-watt max. incandescent light bulb
For vented installations, you also need:
31/4"x 10" (8.3 x 25.4 cm) or 6" (15.2 cm) round metal venting
31/4'' x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) vent transition piece
if using 6" (15.2 cm) round venting.
For cabinets with recessed bottoms:
Two, 2" (5.1 cm) wide filler strips. Length and thickness
determined by recess dimensions.
Four flat head wood screws or machine screws with washers
and nuts (to attach filler strips).
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the range hood on
the rear wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
12"
(30.5 cm) 9"
(2.5cm)
(15.2
23%" (60.6 cm) - 24" {61,Oore} mode(
171/2
29%" (75.9 cm} o30"(76.2 cm} mode( (44.5cm}
357/8'' (91.1 cm} - 36" (91.4 cm} mode( _ , _,,_
Cabinet Dimensions
18"1
upper cabinet
to eeuntertop
' l
24" (61.0
30" (76=2
_ 36" (91=4
". cabinet opemng wuc
24" (61 cm) min_
30" (76.2 cm)
suggested max=
bottom of cabinet
to cooking surface
36" (91.4 cm)
base cabinet
height
Cold weather installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break,
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of make up air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
Vent system can terminate either through the roof or wall. Use
31/4'' x 10" (8.3 x 25.4 cm) with a maximum recommended vent
length of 35 ft (10.7 m) or 6" (15.2 cm) round vent with a
maximum length of 50 ft (15.2 m)for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that gently reduces
performance.
Roof Venting Wall Venting
B ......................
C
Vent system must terminate to the outdoors, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area,
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 6" (15,2 cm) or a 31/4'' x 10" (8,3 x 25.4 cm) round metal
vent, Rigid metal vent is recommended. Plastic or metal foil
vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows,
Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the
cap,
A. 6" (15.2 cm) round vent or a
3V4"x 10" (8.3x25.4 cm) vent
through roof
B. Round vent: use 6" (15.2 cm)
round damper
(purchased separately)
C.24" (61 cm) to 30" (76.2 cm)
above cooking surface
D. Roof cap
A. 6" (15.2 cm) round vent or a
3V4"x 10" (8.3 x 25.4 cm) vent
through the wall
B. 3V4"x 10" (8.3 x 25.4 cm) vent
through the wall
C. 24" (61 cm) to 30" (76.2 cm)
above cooking surface
D. Wall cap
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) Vent System
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft
(o.8m)
90° elbow 5.0 ft
(1.5 m)
3W' x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece 31/4'' x 10" (8.3 cm x 25.4 cm)
31/4"x 10" (8.3 cm x 25.4 cm) 5.0 ft
90° elbow (1.5 m)
31/4"x 10" (8.3 cm x 25.4 cm) 12.0 ft
flat elbow (3.7 m)
31/4"x 1O" (8.3 cm x 25.4 cm) O.Oft
wall cap (0.0 m)
6" (15.2 cm) 0.0 ft
wall cap (0.0 m)
31/4'' x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) (1.4 m)
31/4"x 10" (8.3 cm x 25.4 cm) 5.Oft
to 6" (15.2 cm) 90 ° elbow (1.5 m)
Example vent system
90 ° e_bows
31/4"×10"
(8=3 × 25.4 cm) _
to 6" (15.2 cm}
transition L_ _
2 ft (0.6 m)
Maximum Recommended Length = 26 ft (7.9 m)
1 - transition
2 - 90° elbows
1 - wall cap
8 ft (2.4 m) straight
Length of 6" (15.2 cm) system
= 4.5 ft (1.4 m)
= 10.0 ft (3.0 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 22.5 ft (6.9 m)
Example vent system
3%" ×10"
(8=3 × 25=4 cm)
e_bow
6 ft (1.8 m) ------€_ I Wall cap
I
Maximum Recommended Length = 26 ft (7.9 m)
1 - 90 ° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 31/4'' x 10" (8.3 cm x 25.4 cm)
system
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)
_iii}}!k::Hiii:;:ii!6C<i::_l!ii%!Xii_t_iik,i'_i:iKri_e!ii'7_!i}_
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
It is not recommended to have a fuse in the neutral or ground
circuit.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1 and
It is not recommended to ground to a gas pipe. C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
INSTALLATIONINSTRUCTIONS
NOTE: For vented installations, it is recommended that the vent
system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting method to
use: roof or wall.
2. Select a flat surface for assembling the range hood. Place
covering over that surface.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
3.
4.
Using two or more people, lift the range hood onto covered
surface.
If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
3"
Wood filler strips
(recessed cabinet
bottoms only)
Determine Wiring Hole Location
Cut only one 11/4"(3.2 cm) diam. wiring access hole. See Step 2
for wiring hole location instructions. Either wiring hole can be
used.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
!
/
I
A. Centerline
3" Wall
(7.¢ cm)
2.
To wire through top:
Mark a line 71/2'' (19 cm) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5 cm) from back wall, Drill a 1W' (3 cm) diameter hole
through the cabinet at this point.
71/2,, I 2" (5.1ore)
(19 cm) i from wall,
, not cabinet
i frame
i
i
i
Centerline
To wire through rear wall:
Mark a line 71/2"(19 cm) from the right of the centerline on the
wall. Mark the point on this line that is 651A'' (165.7 cm) from
the floor [or %" (1.9 cm) from underside of cabinet]. Drill a
1W' (3 cm) diameter hole through wall at this point.
Style 1 - Cut Openings for 31/4'' x 10" (8.3 cm x 25.4 cm)
Rectangular Vent Sytem
Roof Venting
To make a 4" x 10V2" (10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:
1. Mark lines 11/2'' (3.8 cm) and 51/2'' (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5W' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4.
Repeat steps 1-3 for the underside of the top of the cabinet
Wall Venting
To make a 4" x lOW' (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65%" (167.3 cm) and
62%" (158.4 cm) or %" (3.2 mm) and 3%" (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5W' (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet / CenterHne
-
(3.2 ram) i
3%" %"
(9.2 era) i (13.3 era)
Style 2 - Cut Openings for 31/4'' x 10" (8.3 x 25.4 cm)
Rectangular Vent to 6" (15.2 cm) Round Vent Transition
Roof Venting
To make a 4" x 101/2'' (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 11/2'' (3.8 cm) and 51/2'' (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5W' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
(14ore) / 51/.-
(13.3 em
5W' lh
(13.3 cm)
*From wall, not cabinet frame
To make a 61/4'' (15.9 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 4%" (12.1 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 61/4'' (15.9 cm) circle
template.
(14 am) i
5V_" /h
(13.3 era)
*From wall, not cabinet frame
4.
Use saber or keyhole saw to cut a 61/4'' (15.9 cm) diameter
opening.
61/4" (15=6 cm) diam.
*From wall not
cab net frame
4
.....cutouts
5. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements" section.
6. Use caulking to seal exterior wall or roof opening around the
cap.
1. Remove terminal box cover.
2,
3,
A. Terminal box cover
For vented model installations only:
Remove either top or rear rectangular vent knockout. Install
vent connector/damper using the 2 - #8B sheet metal screws
provided.
Depending on your installation, remove either back or top
wiring hole knockout.
A
4.
5,
6,
Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
A. Keyhole slot
Use 1/8"(3 mm) drill bit and drill 4 pilot holes as shown.
A
A. Drillpilot hole.
Install the 4- #10 x %" mounting screws in pilot holes. Leave
about 1/4"(6.4 cm) space between screw heads and cabinet
to slide range hood into place.
\\\\\\ \\\ _
1/4"
(6.4 ram)
Electrical Shock Hazard
Disconnect power before servicing,
Replace aimparts and panels before operating.
Failure to do so can result in death or electrical shock.
7. For Direct Wire Installations:
Install a UL listed or CSA approved strain relief.
.................
C B
A. Wiring hole knockouts
B. Vent knockouts
C. #8B sheet metal screws
NOTE: If the wall cap is directly behind the vent connector/
damper, the damper in the connector and wall cap must not
interfere with each other. Remove the vent connector damper
if it interferes.
A
A. ULlisted or CSAapproved strain relief
Pull about 12" (30 cm) of wire through wall or cabinet and
into opening.
For Power Supply Installations:
Follow instructions included with power supply cord kit
marked for range hoods.
8. Using2people,liftrangehoodintofinalposition,feeding
electricalwirethroughwiringopening.Positiontherange
hoodsothatthelargeendofthekeyholeslotsareoverthe
screws.Thenpushthehoodtowardthewallsothatthe
screwsareintheneckoftheslots.Tightenmountingscrews
tocabinet,makingsuremountingscrewsareinnarrowneck
ofslots.
9. Checkthatthedamper,ifused,rotatesupanddownfreely.
10. For vented model installations only:
Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
Install 75-watt (max.) incandescent light bulb.
1. Squeeze the plastic lens cover and remove it from the hood.
B
Fire Hazard
EmectricaHy ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminam box.
FaiBure to do so can resumt in death, fire, or
eiectricam shock,
Direct Wire Installation
1. Connect the white wire of the home power supply with the
white wire in the range hood using a UL listed twist-on
connector.
g
A. Light bulb socket
B. Lens cover
2. Screw light bulb into socket.
3. Replace lens cover by squeezing cover and inserting tabs
into slots.
Check Range Hood Operation
1. Check light operation only by pressing light button.
2. Check operation of fan by pressing button to Hi and Lo
positions.
3. If the range hood does not operate, check to see whether a
circuit breaker has tripped or a house fuse has blown.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located on the front right-hand side of the
range hood.
A B
D
E
A.White wires
B.Black wires
C.Green ground screw
D.Ground wire
E.UL listed or CSA approved strainrelief
2. Connect the black wire of the home power supply with the
black wire in the range hood using a UL listed twist-on
connector.
3. Connect ground wire (green or bare) of home power supply to
the green ground screw in the terminal box.
4. Tighten strain relief screws.
5. Install the terminal box cover.
6. Reconnect power.
HI FAN LO UGHT
A. Fan control
B. Light control
Operating the Light
Press light control to turn light on or off. Light may be turned off
or on anytime during range hood operation.
Operating the Fan
Press fan control to turn fan on and off and adjust fan speed.
Speed may be increased or decreased anytime during range
hood operation.
10
RANGE HOOD CARE
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior surfaces:
Do not use steel wool or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter:
For vented installations:
1. Turn the filter retainer to release filter.
A. Filter re tainer
2. Wash metal filters as needed in dishwasher or hot detergent
solution.
3. Reinstall the filter by placing the back edge in the channel at
rear of hood. Push filter into place, turn the filter retainer to
reattach filter to range hood.
Non-vented (recirculating) Installation Filters:
The charcoal filter is not washable. Replace with Kit Number
4396846.
To replace charcoal filter:
1. Turn the filter retainer to release the charcoal filter.
2. Install new charcoal filter with the blue side against the range
hood by placing back edge of filter in channel at rear of range
hood.
3. Push filter up into place. Turn the filter retainer to reattach
filter to range hood.
ASSISTANCEOR SERVICE
When calling for assistance or service, please know the purchase
date and the complete model and serial number of your
appliance. This information will help us to better respond to your
request.
If you need replacement parts
If you need to order replacement parts, we recommend that you
use only factory specified parts. Factory specified parts will fit
right and work right because they are made with the same
precision used to build every new appliance. To locate factory
specified parts replacement parts in your area, call us or your
nearest Whirlpool designated service center.
Call the Whirlpool Customer eXperience Center
toll free: 1-800-253-1301.
Our consultants provide assistance with:
Featuresand specifications on our full line of appliances.
Installation information.
Use and maintenance procedures.
Accessory and repair parts sales.
Specialized customer assistance (Spanish speaking, hearing
impaired, limited vision, etc.).
Referrals to local dealers, repair parts distributors and service
companies. Whirlpool designated service technicians are
trained to fulfill the product warranty and provide after-
warranty service, anywhere in the United States.
To locate the Whirlpool designated service company in your
area, you can also look in your telephone directory Yellow
Pages.
For further assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, M149022-2692
Please include a daytime phone number in your correspondence.
Call the Whirlpool Canada LP Customer Interaction Centre toll
free: 1-800-807-6777.
Our consultants provide assistance with:
Features and specifications on our full line of appliances.
Use and maintenance procedures.
Accessory and repair parts sales.
Referrals to local dealers, repair parts distributors, and
service companies. Whirlpool Canada LP designated service
technicians are trained to fulfill the product warranty and
provide after-warranty service, anywhere in Canada.
For further assistance
If you need further assistance, you can write to Whirlpool
Canada LP with any questions or concerns at:
Customer Interaction Centre
Whirlpool Canada LP
1901 Minnesota Court
Mississauga, Ontario L5N 3A7
Please include a daytime phone number in your correspondence.
11
WHIRLPOOLCORPORATION MAJOR APPLIANCEWARRANTY
ONE YEAR LIMITED WARRANTY
For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or
furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter "Whirlpool") will pay for Factory Specified Parts
and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company.
This limited warranty applies only when the major appliance is used in the country in which it was purchased.
ITEMS WHIRLPOOL WILL NOT PAY FOR
1. Service calls to correct the installation of your major appliance, to instruct you how to use your major appliance, to replace or repair
house fuses or to correct house wiring or plumbing.
2. Service calls to repair or replace appliance light bulbs, air filters or water filters. Those consumable parts are excluded from warranty
coverage.
3. Repairs when your major appliance is used for other than normal, single-family household use.
4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in
accordance with electrical or plumbing codes, or use of products not approved by Whirlpool.
5. Any food loss due to refrigerator or freezer product failures.
6. Replacement parts or repair labor costs for units operated outside the United States or Canada.
7. Pickup and delivery. This major appliance is designed to be repaired in the home.
8. Repairs to parts or systems resulting from unauthorized modifications made to the appliance.
g. Expenses for travel and transportation for product service in remote locations.
10. The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with
published installation instructions.
11. Replacement parts or repair labor costs when the major appliance is used in a country other than the country in which it was
purchased.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED
HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,
ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. WHIRLPOOL SHALL NOT BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATETO STATE OR PROVINCE
TO PROVINCE.
Outside the 50 United States and Canada, this warranty does not apply. Contact your authorized Whirlpool dealer to determine if
another warranty applies.
If you need service, first see the "Troubleshooting" section of the Use & Care Guide. After checking "Troubleshooting," additional help
can be found by checking the "Assistance or Service" section or by calling Whirlpool. Inthe U.S.A., call 1-800-253-1301. In Canada,
call 1-800-807-6777. 12/o5
Keep this book and your sales slip together for future
reference. You must provide proof of purchase or installation
date for in-warranty service.
Write down the following information about your major appliance
to better help you obtain assistance or service if you ever need it.
You will need to know your complete model number and serial
number. You can find this information on the model and serial
number label located on the product.
Dealer name
Address
Phone number
Model number
Serial number
Purchase date
12
SECURITEDELA HOTTEDECUISINIERE
Votre s_curit_ et celle des autres est trbs importante.
Nous donnons de nombreux messages de securite importants dans ce manuel et sur votre appareil menager. Assurez-vous de
toujours lire tousles messages de securite et de vous y conformer.
Voici le symbole d'alerte de securite.
Ce symbole d'alerte de securite vous signale les dangers potentiels de deces et de blessures graves & vous
et & d'autres.
Tousles messages de securite suivront le symbole d'alerte de securite et le mot "DANGER" ou
"AVERTISSEMENT". Ces roots signifient :
Risque possible de deces ou de blessure grave si vous ne
euivez pas immediatement lee instructions.
Risque possible de deces ou de blessure grave si vous
ne euivez pas lee instructions.
Tousles messages de securite vous diront quel est le danger potentiel et vous disent comment reduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
13
IMPORTANTES iNSTRUCTiONS DE SECURITE
AVERTISSEMENT : POUR REDUHRE LE RHSQUE
D'HNCENDHE,CHOC ELECTRHQUE OU DOMMAGES
CORPORELS, RESPECTER LES HNSTRUCTHONS
SUHVANTES :
m Utiliser cet appareiI uniquement dans Ies applications
envisag6es par Ie fabricant. Pour toute question, contacter
le fabricanL
m Avant d'entreprendre un travail d'entretien ou de nettoyage,
interrompre I'alimentation de Ia hotte au niveau du tableau
de disjoncteurs, et verrouiIler le tableau de disjoncteurs
pour emp6cher tout r6tablissement accidentel de
I'alimentation du circuit. Lorsqu'iI n'est pas possibIe de
verrouiller Ie tableau de disjoncteurs, placer sur le tabteau
de disjoncteurs une 6tiquette d'avertissement pro6minente
interdisant le r6tablissement de I'alimentation.
m Tout travaiI d'installation ou c_bIage electrique doit 6tre
r6alis6 par une personne qualifi6e, dans Ie respect des
prescriptions de tousles codes et hermes applicabIes, y
compris les codes du bb.timent et de protection centre les
incendies.
m Une source d'air de d6bit suffisant est necessaire pour le
fonctionnement correct de tout appareil b.gaz (combustion
et evacuation des gaz a combustion par la cheminee), pour
qu'iI n'y ait pas de reflux des gaz de combustion. Respecter
les directives du fabricant de I'6quipement de chauffage et
les prescriptions des normes de s6curite - comme celles
publi6es par Ia National Fire Protection Association (NFPA)
et I'American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), et les prescriptions des
autorit6s r6gIementaires !ocales.
m Lors d'operations de decoupage et de per_age darts un mur
ou un plafond, veilIer & ne pas endommager les cablages
61ectriques ou canaIisations qui peuvent s'y trouver.
m Les ventilateurs d'6vacuation doivent touiours decharger
I'air a I'ext6rieur.
MISE EN GARDE : Cet appareiI est con_u uniquement
pour la ventilation g6n6raIe. Ne pas I'utiliser pour I'extraction
de matieres ou vapeurs dangereuses ou explosives.
MmSE EN GARDE : Pour minimiser le risque d'incendie
et evacuer adequatement les gaz, veiller a acheminer I'air
aspir6 par un conduit jusqu'a I'ext6rieur - ne pas decharger
I'air aspire dans un espace vide du b&timent comme une
cavite muraIe, un plafond, un grenier, un vide sanitaire ou
un garage.
AVERTISSEMENT : POUR REDUIRE LE RISQUE
D'HNCENDHE,UTHLHSERUNHQUEMENT DES CONDUHTS
AVERTISSEMENT : POUR MHNHMHSERLE RHSQUE
D'UN FEU DE GRAHSSE SUR LA CUISINIERE :
= Ne iamais laisser un 616ment de surface fonctionner &
puissance de chauffage maximale sans surveillance. Un
renversement/debordement de matiere graisseuse pourrait
provoquer une inflammation et Ia gen6ration de fum6e.
Utiliser une puissance de chauffage moyenne ou basse
pour le chauffage d'huile.
m VeilIer a toujours faire fonctionner Ie ventilateur de la hotte
Iors de la cuisson avec une puissance de chauffage eIev6e
ou Iors de la cuisson d'un mets a fiamber (a savoir cr6pes
Suzette, cerise iubiIee, steak au poivre fiambe).
m Nettoyer frequemment les ventilateurs d'extraction. Veiller
ne pas laisser la graisse s'accumuler sur les surfaces du
ventilateur ou des filtres.
m Utiliser touiours un ustensile de taiIIe appropriee. Utiliser
touiours un ustensile adapte a la taille de 1'61ement
chauffant.
AVERT_SSE_ENT : POUR REDUIRE LE RISQUE DE
DOMMAGES CORPORELS APRES LE DECLENCHEMENT
D'UN FEU DE GRAHSSE SUR LA CUISINIERE, APPLHQUER
LES RECOMMANDATHONS SUHVANTES :a
m Placer sur le r_cipient un couvercte bien ajust_, une t61e&
biscuits ou un plateau m6tallique POUR ETOUFFER LES
FLAMMES, puis eteindre Ie brOleur. VEHLLER A EVITER
LES BROLURES. Si Ies fiammes ne s'eteignent pas
imm6diatement, EVACUER LA PIECE ET APPELER LES
POMPHERS.
= NE JAMAHS PRENDRE EN MAiN UN RECIPIENT
ENFLAMME - vous risquez de vous brOIer.
= NE PAS UTHLHSERD'EAU, ni un torchon humide - ceci
pourrait provoquer une explosion de vapeur brOlante.
m Utiliser un extincteur SEULEMENT si :
- HIs'agit d'un extincteur de classe ABC, dent on conna?t le
fonctionnement.
- HIs'agit d'un petit feu encore limite &I'endroit ou il s'est
declar&
- Les pompiers ont ete contactes.
- HIest possible de garder Ie dos oriente vers une sortie
pendant I'operation de Iutte centre Ie feu.
aRecommandations tir_es des conseils de securite en cas
d'incendie de cuisine publies par Ia NFPA.
® AVERT_SSE_ENT : Pour reduire le risque d'incendie
ou de choc electrique, ne pas utiIiser ce ventilateur avec un
quelconque dispositif de reglage de la vitesse a semi-
conducteurs.
CONSERVEZ CES iNSTRUCTiONS
14
EXIGENCESD'INSTALLATION
Cii_,;i_ii)iiiii::::!,!!i_i_:i!i_¸,_,i_:_ii!_!i¸¸¸il::ii:i_,)ii,_i_,O_i::__i!!ii_,
Rassembler les outils et pieces necessaires avant de commencer
I'installation. Lire et suivre les instructions fournies avec les outils
indiques ici.
Outils n_cessaires
Perceuse
Foret de 11A" (3 cm)
Foret de %" (3 mm) pour avant-trous
Crayon
Pince a denuder ou couteau utilitaire
Metre-ruban ou r_gle
Pistolet & calfeutrage et compose de calfeutrage resistant
aux intemperies
Tournevis & lame plate
Tournevis Phillips
Pour une installation avec decharge a I'ext_rieur, vous aurez
_galement besoin de :
Scie sauteuse ou scie &guichet
Compas ou gabarit circulaire de 61/4'' (15,9 cm) [si on utilise
un conduit rectangulaire de 31/4'' x 10" (8,3 x 25,4 cm) sur
raccord de transition de 6" (15,2 cm)]
Brides de serrage pour conduit d'evacuation
Cisaille de ferblantier
Pieces fournies
Retirer les pieces de I'emballage. Verifier que toutes les pieces
sent presentes.
4 vis Phillips n° 10 x %", type A
Filtre
Connecteur/clapet de conduit de 3W' x 10" (8,3 x 25,4 cm)
2 vis det61erie n° 8B
Pi_ces n_cessaires
Pour une installation a raccordement direct
Serre-c&ble de 1/2"(12,5 mm) (homologation UL ou CSA)
Lampe a incandescence - 75 watts maximum
C&ble d'alimentation (si necessaire pour une installation
raccordement direct)
Pour une installation avec cordon d'alimentation _lectrique
Ensemble de connexion - Cordon d'alimentation electrique
(homologation UL) con(_u pour I'utilisation sur une hotte de
cuisiniere.
Lampe a incandescence - 75 watts maximum
Pour une installation avec decharge a I'ext_rieur, vous aurez
_galement besoin de :
Conduit metallique pour circuit d'evacuation 31/4"x10" (8,3 x
25,4 cm) ou dia. 6" (15,2 cm)
Raccord de transition de 31A" x 10" (8,3 x 25,4 cm), dia.
6" (15,2 cm), si on utilise un conduit rond de 6" (15,2 cm)
Pour placards avec cavit_ au fond :
Deux tringles d'appui de largeur 2" (5,1 cm). Longueur et
epaisseur selon les dimensions du placard.
Quatre vis & bois a t_te plate ou vis & metaux avec rondelles
et ecrous, pour la fixation des tringles d'appui.
[:::: t_
IMPORTANT : Observer les dispositions de tousles codes et
reglements en vigueur.
C'est a I'installateur qu'incombe la responsabilite de
respecter les distances de separation exigees, specifiees sur
la plaque signaletique de I'appareil. La plaque signaletique
est situee a I'interieur de la hotte, sur la paroi arriere.
Installer la hotte de cuisiniere & distance de toute zone
exposee a des courants d'air, comme fen_tres, portes et
bouches de chauffage.
Respecter les dimensions indiquees pour la cavite
d'installation entre les placards. Les dimensions indiquees
prennent en compte les valeurs minimales des degagements
de separation necessaires. Avant d'effectuer des
decoupages, consulter les instructions d'installation fournies
par le fabricant de la table de cuisson/cuisiniere.
On dolt disposer d'une prise de courant _lectrique reliee &la
terre. Voir la section "Specifications electriques".
Assurer I'etancheite au niveau de chaque ouverture
decoupee dans le plafond ou lemur pour I'installation de la
hotte de cuisiniere.
Installation dans une r_sidence mobile
L'installation de cette hotte dolt satisfaire aux exigences de la
norme Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (anciennement Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280); Iorsque
cette norme n'est pas applicable, I'installation dolt satisfaire aux
crit_res de la plus recente edition de la norme Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A*, ou des codes et
reglements Iocaux.
___________________________________________________________________________________________r
Dimensions du produit
(2,5era)
15
d6gagameat
antra placard
sup= et p_aa
de travai_
18" (45,7 ore)
rain.
profof_deur J-
placard
13" (33 am)
haLitaHr
p_acard du has
36" (51,4 cm)
rain.
76 %_"
(193,8am)
max=
au bard irff_
du cadre
de p_acard
Le systeme d'evacuation dolt decharger I'air & I'exterieur,
excepte pour les installations sans decharge a I'exterieur
(recyclage).
Ne pas terminer le conduit d'evacuation dans un grenier ou
dans un autre espace ferm&
Ne pas utiliser une bouche de decharge murale de
4" (10,2 cm) normalement utilisee pour un equipement de
buanderie.
Utiliser un conduit metallique de 3 ¼" x 10" (8,3 x 25,4 cm) ou
de diametre 6" (15,2 cm). Un conduit en metal rigide est
recommand& Ne pas utiliser un conduit de plastique ou en
feuille metallique.
La Iongueur du syst_me d'evacuation et le hombre de coudes
doivent _tre reduits au minimum pour fournir la meilleure
performance.
Pour un fonctionnement efficace et silencieux :
Ne pas utiliser plus de trois coudes a 90°.
S'assurer qu'il y a au minimum un conduit rectiligne de
24" (61 cm) entre les coudes si plusieurs coudes sont utilises.
Ne pas installer deux coudes ensemble.
Utiliser des brides pour conduits pour assurer I'etancheite au
niveau de chaque jointure du conduit de decharge.
Le systeme d'evacuation dolt comporter un clapet. Si la
bouche de decharge murale ou par le toit comporte un
clapet, ne pas utiliser le clapet fourni avec la hotte de
cuisiniere.
Autour de la bouche de decharge a I'exterieur, assurer
I'etancheite avec un produit de calfeutrage.
Installations pour r_gions & climat froid
On dolt installer un clapet anti-reflux additionnel &I'arriere pour
minimiser le reflux d'air froid, et incorporer un element d'isolation
thermique pour minimiser la conduction de chaleur par
I'intermediaire du conduit d'evacuation, de I'interieur de la
maison a I'exterieur. Le clapet anti-reflux dolt _tre place du c6te
air froid par rapport & I'element d'isolation thermique.
L'element isolant thermique dolt _tre aussi proche que possible
de I'endroit ou le syst_me d'evacuation s'introduit dans la partie
chauffee de la maison.
Air d'appoint
Le code du b&timent local peut exiger I'emploi d'un systeme
d'appoint d'air Iors de I'emploi d'un ventilateur d'extraction dont
la capacite d'aspiration est superieure a un debit (pieds cubes
par minute) specifi& Le debit specifie, pieds cubes par minute,
est variable d'une juridiction a une autre. Consulter un
professionnel des installations de chauffage ventilation/
climatisation au sujet des exigences specifiques applicables
dans la juridiction locale.
M_thodes d'_vacuation
La decharge a I'exterieur du circuit d'evacuation peut se faire &
travers le toit ou a travers un mur. La Iongueur effective du circuit
ne dolt pas depasser 35 pi (10,7 m) dans le cas d'un conduit
rectangulaire de 3¼" x 10" (8,3 x 25,4 cm), ou 50 pi (15,2 m) dans
le cas d'un conduit rond de diam_tre 6" (15,2 cm).
REMARQUE : On deconseille I'emploi d'un conduit flexible. Un
conduit flexible peut susciter une retro-pression et des
turbulences de I'air, ce qui reduit considerablement la
performance.
D_charge a travers le toit D_charge a travers le tour
A
C
A. D_charge a travers le toit pour
conduit de dia. 6" (15,2 cm)
ou conduit rectangulaire de
3¼" x 10" (8,3 x 25,4 crn)
B. Conduit fond : utitiser un
clapet de dia. 6" (15,2 crn)
(acquisition s_par_e)
C. 24" (61 cm) a 30" (76,2 crn)
au-dessus de la surface de
cuisson
D. Bouche de d_charge a travers
le toit
A.D_chargea traversle murpour
conduit de dia. 6" (15,2cm)
ou conduit rectangulaire de
3¼" x 10"(8,3x25,4 crn)
B.D_chargea traversle murpour
1
conduit rectangulaire de3V4"x
10" (8,3x 25,4 crn)
C.24" (61cm)a30" (76,2 cm)
au-dessus de lasurface de
cuisson
D.Bouche de d_charge murale
16
Calcul de la Iongueur du circuit d'_vacuation
Pour calculer la Iongueur du circuit d'evacuation necessaire,
additionner les Iongueurs equivalentes (pieds/m_tres) de tousles
composants utilises dans le syst_me.
Syst_me de d_charge de 6" (15,2 cm)
Composant Conduit de diambtre 6" (15,2 cm)
coude a 45° 2,5 pi
(0,8m)
coude a 90° 5 pi
(1,5 m)
bouche de decharge 0 pi
murale 6" (15,2 cm) (0 m)
31/4"x 10" (8,3 cm x 4,5 pi
25,4 cm) a 6" (15,2 cm) (1,4 m)
coude a 90° de 3%" x 5 pi
10" (8,3 cm x 25,4 cm) & (1,5 m)
6" (15,20m)
Exemple de syst_me de d_charge
coudes a 90 °
[_ epi _[ Bouchede
d_charge mura[e
31/4"x 10" [_ (1,0 m)
(0,3 × 25A cm)
.............
de 5" (15,2 cm)
2 pi (0,0 m)
Longueur maximum = 26 pi (7,9 m)
1 - raccord de transition
2 - coudes a 90°
1 - bouche de decharge murale
section droite de 8 pi (2,4 m)
Longueur du systeme de
dia. 6" (15,2 cm)
= 4,5 pi (1,4 m)
= 10 pi (3 m)
= 0 pi (0 m)
= 8 pi (2,4 m)
= 22,5 pi (6,9 m)
Syst_me de d_charge de 3W' x 10" (8,3 cm x 25,4 cm)
Composant 3W' x 10" (8,3 cm x 25,4 cm)
coude a 90 ° de 3%" x 10" 5 pi
(8,3 cm x 25,4 cm) (1,5 m)
coude plat de 3%" x 10" 12 pi
(8,3 cm x 25,4 cm) (3,7 m)
bouche de decharge murale 0 pi
de 31/4"x 10" (8,3 cm x (0m)
25,4 cm)
Exemple de syst_me de d_charge
Coude de 3 _/4" x 10"
(8,3 × 25,4 cm)
Bouche de
_- 5 pi (1,0 m) ---4_[ d_charge _ura[e
2 pi (0,6 r_l [
Longueur maximum = 26 pi (7,9 m)
1 - coude a 90°
section droite de 8 pi (2,4 m)
1 - bouche de decharge murale
Longueur du systeme
de 3%" x 10" (8,3 cm x 25,4 cm)
= 5 pi (1,5 m)
= 8 pi (2,4 m)
= 0 pi (0 m)
= 13 pi (3,9 m)
Observer les dispositions de tousles codes et reglements en
vigueur.
L'installation electrique dolt satisfaire les exigences de la plus
recente edition de la norme National Electrical Code, ANSl/NFPA
70, ou de la norme CSA C22.1-94, Code canadien de
I'electricite, partie 1 et C22.2 No 0-M91 (derniere edition) et de
tous les codes et reglements en vigueur.
Si les codes le permettent et si on utilise un conducteur distinct
de liaison a la terre, il est recommande qu'un electricien qualifie
verifie la qualite de la liaison a la terre.
Pour obtenir un exemplaire de la norme des codes ci-dessus,
contacter :
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
17
L'appareil doit _tre alimente par un circuit de 120 V, CA
seulement, 60 Hz, 15 amperes, protege par fusible.
II n'est pas recommande d'utiliser une tuyauterie de gaz pour
le raccordement a la terre.
Ne pas installer un fusible dans le conducteur neutre ou le
conducteur de liaison a la terre.
Si le domicile est equipe d'un c&blage en aluminium, suivre
les instructions suivantes :
1. Connecter une section de c&ble en cuivre massif aux
conducteurs en queue de cochon.
2. Connecter le c&blage en aluminium a la section ajoutee
de c&blage en cuivre en utilisant des connecteurs et/ou
des outils specialement congus et homologues UL pour
fixer le cuivre a I'aluminium.
Appliquer la procedure recommandee par le fabricant des
connecteurs. La connexion aluminium/cuivre doit _tre
conforme aux codes Iocaux et aux pratiques de c&blage
acceptees par I'industrie.
Le calibre des conducteurs et les connexions doivent _tre
compatibles avec la demande de courant de I'appareil
specifiee sur la plaque signaletique. La plaque signaletique
de I'appareil est situee derriere le filtre, sur la paroi arriere de
la hotte.
Le calibre des conducteurs doit satisfaire les exigences de la
plus recente edition de la norme National Electrical Code,
ANSI/NFPA 70, ou de la norme CSA C22.1-94, Code
canadien de I'electricite, partie 1 et C22.2 No 0-M91 (derniere
edition) et de tousles codes et reglements en vigueur.
INSTRUCTIONSD'INSTALLATION
REMARQUE : Installations avec decharge a I'exterieur : on
recommande d'installer le circuit d'evacuation avant
d'entreprendre I'installation de la hotte.
Avant d'executer les decoupages, verifier la disponibilite d'un
espace de passage suffisant dans le plafond ou le mur pour le
conduit d'evacuation.
1. Pour les installations avec decharge a I'exterieur, determiner
la methode d'evacuation a utiliser : a travers le toit ou
travers le tour.
2. Selectionner une surface plane pour I'assemblage de la
hotte. Placer le materiau de protection sur cette surface.
Risque du poids excessif
UtHiser deux ou pmusde personnes pour depiacer et
installer la hotte de la cuisiniereo
Le non-respect de cette instruct(on peut causer
une bmessure au dos ou d'autre blessure.
D_terminer I'emplacement du trou de passage du c&ble
Percer seulement un trou de passage de 11/4'' (3,2 cm) de
diametre pour le c_ble d'alimentation. Voir I'etape 2 pour des
instructions sur I'emplacement du trou de passage du c&ble. On
peut utiliser I'un ou I'autre des emplacements indiques pour le
trou de passage du c_ble.
1. Sur lemur et le placard dans la zone ou le passage du
conduit d'evacuation va _tre realise, determiner et tracer I'axe
central vertical.
3. A I'aide de deux personnes ou plus, soulever la hotte et la
poser sur la surface couverte.
4. Si le fond du placard forme une cavite, ajouter des tringles
d'appui en bois de chaque c6te. Installer les vis pour fixer les
tringles d'appui aux emplacements indiques.
3"
Tringies d'appui en bois
(seu_ement pour fond de
p(aeard avec cavitY)
3" MUr
(7,ecm)
A. Axe central
2.
C&blage a travers le fond du placard :
Tracer une ligne a 71/2"(19 cm) a droite de I'axe central, sur la
face inferieure du placard. Sur cette ligne, marquer le point
situe a 2" (5 cm) du mur arriere. Percer en ce point un trou de
11A'' (3 cm) de diam&tre a travers le fond du placard.
71/2" ( 2" (5,1 era) _ partir
(19era) ! dumur, etnondu
( cadre du placard
1
Axe centra(
18
C_blage a travers le tour arribre :
Tracer une ligne & 71/2'' (19 cm) & droite de I'axe central trace
sur lemur. Sur cette ligne, marquer le point situe & 651/4''
(165,7 cm) du plancher [ou 3A"(1,9 cm) du fond du placard].
Percer & cet endroit un trou de 1W' (3 cm) de diametre &
travers le mur.
i
Ili
1j
I
i i
/
' ' _/4"(1,9crn)
65!/,, I 7 V2"
(165,7 cm) i(19 cm) \
jusqu'au sol 1
_ Axecentral
Style I - D_coupage d'ouverture pour un syst_me
d'_vacuation rectangulaire de 31/4'' x 10" (8,3 cm x
25,4 cm)
D_charge & travers le toit
Decoupage d'une ouverture rectangulaire de 4" x 101/2'' (10,2 cm
x 26,7 cm) dans le fond et le sommet du placard :
1. Tracer des lignes & 11/2"(3,8 cm) et 51/2'' (14 cm) du mur arriere
sur I'axe central de la face inferieure du placard.
2. Tracer des lignes & 5W' (13,3 cm) de part et d'autre de I'axe
central sur la face inferieure du placard.
3. Utiliser une scie sauteuse ou une scie a guichet pour
decouper I'ouverture rectangulaire pour le passage du
conduit d'evacuation.
4. Repeter les etapes 1 & 3 pour la paroi du sommet du placard.
D_charge & travers le tour
Decoupage d'une ouverture rectangulaire de 4" x 101/2'' (10,2 cm
x 26,7 cm) dans lemur :
1. Tracer 2 lignes & partir du sol en mesurant 657/8'' (167,3 cm) et
623/8'' (158,4 cm) ou 1/8"(3,2 ram) et 3%" (9,2 cm) a partir de la
face inferieure du placard et marquer I'axe central sur le tour
arriere.
2. Tracer des lignes a 5W' (13,3 cm) de part et d'autre de I'axe
central sur le tour.
3. Utiliser une scie sauteuse ou une scie a guichet pour
decouper I'ouverture rectangulaire du syst_me d'evacuation
dans lemur.
/ Axe centra_
L_L Avant du I/
JL ,acard 11
(3,2 ram)
3%" i "4 51/_''
(9,2 cm) _ (13,3 cm)
Style 2 - D_coupage d'ouverture pour un conduit
rectangulaire de 3% "x 10" (8,3 x 25,4 cm) sur raccord de
transition rond de diam_tre 6" (15,2 cm)
D_charge _ travers le toit
Decoupage d'une ouverture rectangulaire de 4" x 101/2'' (10,2 cm
x 26,7 cm) sous le placard :
1. Tracer des lignes & 11/2"(3,8 cm) et 51/2'' (14 cm) du mur arriere
sur I'axe central de la face inferieure du placard.
2. Tracer des lignes & 51/4'' (13,3 cm) de part et d'autre de I'axe
central sur la face inferieure du placard.
3. Utiliser une scie sauteuse ou une scie & guichet pour
decouper I'ouverture rectangulaire pour le passage du
conduit d'evacuation.
(14 cm) /
5W' /I,
(13,3 cm)
*_, partir du mar, et non
du cadre du p_acard
(14 cm)
51/4"
(13,3 cm}
*_, partir da mar, et non
du cadre du p_acard
Decoupage d'une ouverture circulaire de 6W' (15,9 cm) sous le
placard :
1. Tracer un axe central sur la partie inferieure du sommet du
placard.
2. Tracer une ligne de 4_A'' (12,1 cm) en partant du mur arriere
sur la partie inferieure du sommet du placard.
3. Tracer un cercle en utilisant un compas ou un gabarit
circulaire de 6W' (15,9 cm).
19
4,
Utiliser une scie sauteuse ou une scie a guichet pour
decouper une ouverture de 61A'' (15,9 cm) de diametre,
6!/4 `' (15,6 cm) diam.
5. Installer le conduit d'evacuation a travers les ouvertures
decoupees dans le placard mural ou lemur. Achever
I'installation du syst_me d'evacuation conformement a la
methode d'evacuation selectionnee. Voir la section
"Exigences concernant I'evacuation".
6. Autour de la bouche de decharge a I'exterieur, assurer
I'etancheite avec un produit de calfeutrage.
2,
3,
Oter le couvercle du boitier de connexion.
A. Couvercle du bottler de connexion
Pour les installations avec d_charge a I'ext_rieur
uniquement :
Enlever I'opercule arrachable de I'ouverture rectangulaire de
I'arriere ou du sommet. Installer le module connecteur/clapet
I'aide des 2 vis de t61erie n° 8B fournies,
Selon votre configuration d'installation, enlever un opercule
arrachable a I'arriere ou au sommet pour le passage du c&ble
d'alimentation.
C
4,
5,
6,
REMARQUE : Si la bouche de decharge murale est situee
directement derriere le module connecteur/clapet, on dolt
veiller a emp_cher toute interference entre les clapets du
connecteur et de la bouche de decharge murale. En cas
d'interference, supprimer le clapet du connecteur de conduit.
Soulever la hotte sous le placard et determiner sa position
d'installation finale en la centrant sous le placard. Sur la face
inferieure du placard, marquer I'emplacement des 4 trous de
montage sur la hotte. Placer la hotte a part sur une surface
couverte.
A
A. Trou pour vis de montage
Avec un foret de 1/8"(3 mm), percer 4 avant-trous - voir
I'illustration,
A
A. Perqage des avant-trous.
Installer les 4 vis de montage n ° 10 de %" dans les avant-
trous. Laisser un espace d'environ 1/4"(6,4 cm) entre les t_tes
des vis et le placard pour glisser la hotte en place.
1/4"
(6,4 ram)
Risque de choc electrique
Deconnecter la source de courant emectrique avant
I'entretien.
Replacer pieces et panneaux avant de faire marernise
en marche.
Le non-respect de ces instructions peut causer
un deces ou un choc emectrique.
7. Pour des installations a raccordement direct :
Installer un serre-c_ble (homologation UL ou CSA).
C B
A. Opercules arrachables pour passage du cgble
d'alimentation
B. Opercules arrachables pour circuit d'_vacuation
C. Vis de tOlerie n° 8B
A
A.Serre-cbble (homologation UL ou CSA)
Tirer environ 12" (30 cm) de c&ble a travers lemur ou le
placard et dans I'ouverture.
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Whirlpool RH2330XJQ3 Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

dans d''autres langues