ENGLISH
Example-1 : If alarm function selection parameter In programming section is 1(Absolute
alarm) and minimum alarm parameter is 20 ;
When temperature is less than 20°C, value on the screen starts to blink. Also if buzzer function
selection parameter is 2 or 4 , then internal buzzer is on.
1. Screen Blinking
Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter is 3 or 4, internal buzzer starts to operate.
15
Device Type : Cooling Controller
Housing&Mounting : 76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cut-out is 71x29mm.
Protection Class : NEMA 4X (Ip65 at front, Ip20 at rear).
Weight : Approximately 0.20 Kg.
Environmental Ratings : Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity.
o o o o
Storage / Operating Temperature: -40 C to +80 C / -30 C to +80 C
Storage / Operating Humidity : 90 % max. (None condensing)
Installation : Fixed installation
Overvoltage Category : II.
Pollution Degree : II, office or workplace, none conductive pollution
Operating Conditions : Continuous
Supply Voltage and Power :
: 115
: 24 ,10-30
Temperature Sensor Input : NTC or PTC
NTC input type : NTC (10 kW @25 °C )
PTC input type : PTC (1000 W @25 °C )
Accuracy : ± 1 % of full scale for thermoresistance
Sensor Break Protection : Upscale
Sampling Cycle : 3 samples per second
Control Form : ON / OFF
Relay Outputs : 16(8) A@250 V V for Resistive load (Compressor
output)
(Electrical life : 100.000 switching at full load)
Display : 14 mm Red 4 digits LED Display
o o
LED : S (Green), P (Green), C (Yellow), F(Yellow), Alarm (Red),
Defrost (Red), Compressor Output (Red)
Internal Buzzer : 83dB
Approvals :
230V ( %15) 50/60Hz - 1.5VA
V ( %15) 50/60Hz - 1.5VA
V ( %15) 50/60Hz - 1.5VA VZ 1.5W
V ±
V ±
V ±
9. Specifications
3 sn.
While defrost time parameter value 1, button protection
parameter value = 0 or 2 and defrost output is inactive,
in main operation screen if defrost button is pressed for
3 seconds defrost operation starts and defrost led becomes
active.If defrost button pressed for 3 seconds while defrost
continues,defrost is finished and defrost led becomes inactive.
8. Manual Defrost Operation with Defrost Button
O
F
O
C
P
S
7. Failure Messages in ESM-3711-CN Cooling Controller
2- Blinking the Screen Value
If temperature higher than the alarm parameters limit, value on the screen starts to blink.
Example-2 : If alarm function selection parameter in programming section is 1 (Absolute
Alarm) and maximum alarm parameter is 50
When temperature is above 50 °C, value on the screen starts to blink. Also buzzer function
selection parameter is 2 or 4, then internal buzzer is on.
ü
ESM-3711CN
,