Manitowoc Ice RF / RFS / RNS Model Guide d'installation

Catégorie
Fabricants de glaçons
Taper
Guide d'installation
Part Number 000007644 Rev 01 12/16
RF/RFS/RNS Model
Ice Machines
Installation, Use and Care Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
www.manitowocice.com
This manual contains English and French Text
Safety Notices
Safety Notices
Read these precautions to prevent personal injury:
Read this manual thoroughly before operating,
installing or performing maintenance on the
equipment. Failure to follow instructions in this
manual can cause property damage, injury or death.
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
Proper installation, care and maintenance are essential
for maximum performance and trouble-free operation
of your equipment.
Visit our website www.manitowocice.com for manual
updates, translations, or contact information for
service agents in your area.
This equipment contains high voltage electricity and
refrigerant charge. Installation and repairs are to be
performed by properly trained technicians aware of
the dangers of dealing with high voltage electricity
and refrigerant under pressure. The technician must
also be certified in proper refrigerant handling
and servicing procedures. All lockout and tag out
procedures must be followed when working on this
equipment.
This equipment is intended for indoor use only. Do
not install or operate this equipment in outdoor areas.
n
Warning
Follow these electrical requirements during
installation of this equipment.
All field wiring must conform to all applicable
codes of the authority having jurisdiction. It is
the responsibility of the end user to provide the
disconnect means to satisfy local codes. Refer to rating
plate for proper voltage.
This appliance must be grounded.
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g., circuit breaker or disconnect
switch) is provided.
Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
Warning
Follow these precautions to prevent personal injury
during installation of this equipment:
Installation must comply with all applicable
equipment fire and health codes with the authority
having jurisdiction.
To avoid instability the installation area must be
capable of supporting the combined weight of the
equipment and product. Additionally the equipment
must be level side to side and front to back.
Ice machines require a deflector when installed on
an ice storage bin. Prior to using a non-OEM ice
storage system with this ice machine, contact the
bin manufacturer to assure their ice deflector is
compatible.
Remove all removable panels before lifting and
installing and use appropriate safety equipment
during installation and servicing. Two or more people
are required to lift or move this appliance to prevent
tipping and/or injury.
Do not damage the refrigeration circuit when
installing, maintaining or servicing the unit.
Connect to a potable water supply only.
This equipment contains refrigerant charge.
Installation of the line sets must be performed by
a properly trained and EPA certified refrigeration
technician aware of the dangers of dealing with
refrigerant charged equipment.
Legs or casters must be installed and the legs/casters
must be screwed in completely. When casters are
installed the mass of this unit will allow it to move
uncontrolled on an inclined surface. These units must
be tethered/secured to comply with all applicable
codes. Swivel casters must be mounted on the front
and rigid casters must be mounted on the rear. Lock
the front casters after installation is complete.
Some 50 Hz models may contain up to 150 grams
of R290 (propane) refrigerant. R290 (propane)
is flammable in concentrations of air between
approximately 2.1% and 9.5% by volume (LEL lower
explosion limit and UEL upper explosion limit). An
ignition source at a temperature higher than 470°C is
needed for a combustion to occur. Refer to nameplate
to identify the type of refrigerant in your equipment.
Only trained and qualified personnel aware of the
dangers are allowed to work on the equipment.
n
Warning
Follow these precautions to prevent personal injury
while operating or maintaining this equipment:
Read this manual thoroughly before operating,
installing or performing maintenance on the
equipment. Failure to follow instructions in this
manual can cause property damage, injury or death.
Crush/Pinch Hazard. Keep hands clear of moving
components. Components can move without warning
unless power is disconnected and all potential energy
is removed.
Moisture collecting on the floor will create a slippery
surface. Clean up any water on the floor immediately
to prevent a slip hazard.
Objects placed or dropped in the bin can affect
human health and safety. Locate and remove any
objects immediately.
Never use sharp objects or tools to remove ice or frost.
Do not use mechanical devices or other means to
accelerate the defrosting process.
When using cleaning fluids or chemicals, rubber
gloves and eye protection (and/or face shield) must
be worn.
DANGER
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications. This
appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision concerning use of the
appliance by a person responsible for their safety. Do
not allow children to play with, clean or maintain this
appliance without proper supervision.
n
Warning
This product is hermetically sealed and contains
fluorinated greenhouse gas R404A.
DANGER
Follow these precautions to prevent personal injury
during use and maintenance of this equipment:
It is the responsibility of the equipment owner to
perform a Personal Protective Equipment Hazard
Assessment to ensure adequate protection during
maintenance procedures.
Do Not Store Or Use Gasoline Or Other Flammable
Vapors Or Liquids In The Vicinity Of This Or Any Other
Appliance. Never use flammable oil soaked cloths or
combustible cleaning solutions for cleaning.
All covers and access panels must be in place and
properly secured when operating this equipment.
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings.
Failure to disconnect power at the main power supply
disconnect could result in serious injury or death.
The power switch DOES NOT disconnect all incoming
power.
All utility connections and fixtures must be
maintained in accordance with the authority having
jurisdiction.
Turn off and lockout all utilities (gas, electric, water)
according to approved practices during maintenance
or servicing.
Units with two power cords must be plugged into
individual branch circuits. During movement, cleaning
or repair it is necessary to unplug both power cords.
Never use a high-pressure water jet for cleaning on
the interior or exterior of this unit. Do not use power
cleaning equipment, steel wool, scrapers or wire
brushes on stainless steel or painted surfaces.
Two or more people are required to move this
equipment to prevent tipping.
Locking the front casters after moving is the owners
and operator’s responsibility. When casters are
installed, the mass of this unit will allow it to move
uncontrolled on an inclined surface. These units must
be tethered/secured to comply with all applicable
codes.
The on-site supervisor is responsible for ensuring that
operators are made aware of the inherent dangers of
operating this equipment.
Do not operate any appliance with a damaged cord
or plug. All repairs must be performed by a qualified
service company.
Table of Contents
Part Number 000007644 Rev 01 12/16 5
Safety Notices
Safety Notices ..................................................................................................................... 3
Section 1
General Information
Model Numbers .................................................................................................................. 7
Flake UnderCounter Models ..............................................................................................................7
Nugget UnderCounter Models ..........................................................................................................7
Nugget Modular Models .....................................................................................................................7
Flake Modular Models ..........................................................................................................................7
Adapters ..............................................................................................................................8
RF2300 Bin Adapter Installation........................................................................................................8
Warranty Information ........................................................................................................8
Arctic Pure Water Filter System ......................................................................................... 8
Manitowoc Cleaner and Sanitizer ..................................................................................... 8
Section 2
Installation Instructions
Location of Ice Machine .....................................................................................................9
Clearance Requirements ......................................................................................................................9
Installation Requirements ................................................................................................. 9
Ice Machine Heat of Rejection ........................................................................................... 9
Rack Unit Connection Size .................................................................................................9
Water and Drain Requirements ....................................................................................... 10
Potable Water Requirements .......................................................................................................... 10
Drain Connections .............................................................................................................................. 10
Cooling Tower Applications ............................................................................................................. 10
Ice Machine Water Usage .................................................................................................................10
Water Supply and Drain Line Sizing/Connections .................................................................. 11
Electrical Service ..............................................................................................................12
Voltage .................................................................................................................................................... 12
Fuse/Circuit Breaker ...........................................................................................................................12
Ground Fault Circuit Interrupter .................................................................................................... 12
Minimum Power Cord Specifications ...........................................................................................12
For United Kingdom Only ................................................................................................................ 12
Maximum Breaker Size & Minimum Circuit Amperage Chart .......................................13
QuietQube Remote Condensing Unit..........................................................................................14
Refrigeration System Installation
Remote Condensing Unit Only .......................................................................................15
Usage with Non-Manitowoc Condensing Units ....................................................................... 15
Refrigeration Line Set Installation
Remote Condensing Unit Only ........................................................................................ 16
General ....................................................................................................................................................16
A. Line Set Length ...............................................................................................................................16
B. Line Set Rise or Drop .....................................................................................................................16
C. Suction Line Oil Traps ....................................................................................................................17
Installation Check List ......................................................................................................20
Additional Checks for QuietQube Models ......................................................................21
6 Part Number 000007644 Rev 01 12/16
Table of Contents (continued)
Section 3
Operation
Bin Thermostat And Evaporator Low Temperature Safety Adjustment Chart ............23
Thermostat Adjustment For Altitude .............................................................................23
Altitude Adjustment Chart .............................................................................................................. 23
RF0244/RF0266/RF0385/
RF0388/RF0399/RF0644 & RNS0244/RNS0385Operation ...........................................24
RFS0300 & RNS0300 Operation ......................................................................................24
RNS0600/RFS0650/RNS1000/RFS1200/RFS2300 & RF1200/RF2300 Operation .........24
Section 4
Maintenance
Interior Cleaning and Sanitizing ..................................................................................... 25
Cleaning/Sanitizing Procedure....................................................................................................... 25
Heavily Scaled Cleaning Procedure .............................................................................................. 25
Exterior Cleaning..............................................................................................................25
Cleaning/Sanitizing Procedure .......................................................................................25
Procedure to Clean Heavily Scaled Flake Ice Machines .................................................26
Removal of Parts for Cleaning/Sanitizing ......................................................................27
Ice Chute Removal .............................................................................................................................. 27
Air-Cooled Condenser Cleaning ......................................................................................28
Removal from Service/Winterization .............................................................................28
Water-Cooled Ice Machines ............................................................................................................. 28
Section 5
Troubleshooting
Checklist ............................................................................................................................29
Avis de sécurité
Avis de sécurité .................................................................................................................31
Part Number 000007644 Rev 01 12/16 7
Model Numbers
This manual covers the following models:
FLAKE UNDERCOUNTER MODELS
Self-Contained
Air-Cooled
RF0244A
RF0266A
RF0385A
RF0388A
RF0644A
NUGGET UNDERCOUNTER MODELS
Self-Contained
Air-Cooled
RNS0244A
RNS0385A
NUGGET MODULAR MODELS
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Rack Unit
Head Section
QuietQube
Head Section
RCU Remote
Condensing Unit
RNS0308A --- --- --- ---
RNS0608A RNS0609W --- --- ---
RNS1008A RNS1009W --- RNS1078C RCU1098
FLAKE MODULAR MODELS
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Rack Unit
Head Section
QuietQube
Head Section
RCU Remote
Condensing Unit
RFS0300A --- --- --- ---
RFS0650A RFS0650W ---- --- ---
RFS1200A RFS1200W RFS1279R RFS1278C RCU1075
RF2300A RF2300W RFS2379R RFS2378C RCU2375
n
Warning
Remove all ice machine panels before lifting and
installing.
,
Caution
Flake ice machines must be installed on a bin. Flake ice
machines cannot be installed on dispensers.
Section 1
General Information
8 Part Number 000007644 Rev 01 12/16
General Information Section 1
Adapters
RF2300 BIN ADAPTER INSTALLATION
n
Warning
PERSONAL INJURY POTENTIAL
RF2300 ice machines are not approved for use on B970
bins. RF2300 ice machines ship with a bracket that must
be used when installing on B1100 and B1400 Series bins.
1. Refer to diagram. Place bracket on bin top and slide
back to engage.
2. Place ice machine on bin: ice machine must fit between
bracket and front ridge.
Warranty Information
Visit www.manitowocice.com for:
Warranty Verification
Warranty Registration
View and download a copy of your warranty
Arctic Pure Water Filter System
Engineered specifically for Manitowoc ice machines. This
water filter is an efficient, dependable, and affordable
method of inhibiting scale formation, filtering sediment,
and removing chlorine taste and odor.
Manitowoc Cleaner and Sanitizer
Manitowoc Ice Machine Metal Safe Cleaner is available in
convenient 16 oz. (473 ml) bottles. Manitowoc Ice Machine
Sanitizer is available in 16 oz. (473 ml) and 1 gal (3.78 L)
bottles.
Cleaner Part Number Sanitizer Part Number
16 oz. 000000084 16 oz. 9405653
1 Gallon 94-05813
Part Number 000007644 Rev 01 12/16 9
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met, select
another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
The water temperature must be at least 37°F (3°C), but
must not exceed 90°F (32°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
The location must not obstruct airflow through or
around the ice machine.
CLEARANCE REQUIREMENTS
Undercounter Units Air-Cooled Water-Cooled
Top 0" (0 cm) 0" (0 cm)
Sides 2" (5 cm) 2" (5 cm)
Back 8" (20 cm) 8" (20 cm)
NOTE: Allowance must be made for removal when the ice machine is built in. Monthly
removal of the top panel is required for cleaning & sanitizing.
Modular Units
Air-
Cooled
Water-
Cooled
QuietQube
Air-Cooled
Top/Sides 8" (20 cm) 8" (20 cm) 0" (0 cm)
Back 5" (13 cm) 5" (13 cm) 0" (0 cm)
RCU Units Remote Condensing Unit
Front/Back 24" (61 cm)
Sides/Top 6" (15.2 cm)
Installation Requirements
The ice machine and bin must be level.
Vent the ice machine and bin drains separately.
Bin drain termination must have an air gap.
A backflow preventer is required on water inlet lines.
The ice machine and bin must be sanitized after
installation.
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the warranty.
Ice Machine Heat of Rejection
Series
Ice Machine
Heat of Rejection
A/C Btuh
Heat of Rejection
Peak Btuh
RF0244 - RF0266
RFS0300
2400 5000
RNS0308 3075 4100
RF0388 - RF0399 3500 5200
RFS0650 - RNS0600 5200 7700
RNS1000 7500 10900
RNS1078C - RFS1200
RN1278C - RFS1279R
7500 14000
RN1400 16000 16400
RF2300 - RFS2300 17000 29500
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing air
conditioning equipment.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added to
an air conditioned environment by an ice machine using a
water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled condenser.
Use the peak figure for sizing the cooling tower.
Rack Unit Connection Size
Model Suction Line Liquid Line
RFS1279R 5/8 inch
(15.9 mm)
3/8 inch
(9.5 mm)
RFS2379R 3/4 inch
(19 mm)
1/2 inch
(12.7 mm)
Section 2
Installation Instructions
10 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
Water and Drain Requirements
POTABLE WATER REQUIREMENTS
Follow these guidelines to install water inlet lines:
Do not connect the ice machine to a hot water supply.
Be sure all hot water restrictors installed for other
equipment are working. (Check valves on sink faucets,
dishwashers, etc.)
If water pressure exceeds the maximum of 80 psig
(552kPA) recommended pressure, obtain a water
pressure regulator from your Manitowoc distributor.
Install a water shut-off valve and union for both the ice
making and condenser water lines.
Insulate water inlet lines to prevent condensation.
Plumbing must conform to local codes.
,
Caution
Do not apply heat to water valve inlet fitting or over-
tighten. This will damage plastic water inlet connection.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice machine
and storage bin:
Drain lines must have a 1.5 inch drop per 5 feet of run
(2.5 cm per meter), and must not create traps.
The floor drain must be large enough to accommodate
drainage from all drains.
Run separate bin and water-cooled condenser drain
lines. Insulate them to prevent condensation.
Vent the bin and ice machine drain to the atmosphere.
The ice machine drain requires an 18" (46 cm) vent. Do
not vent the condenser drain on water-cooled models.
Drains must have a union or other suitable means to
allow in-place disconnection from the ice machine
when servicing is required.
COOLING TOWER APPLICATIONS
A water cooling tower installation does not require
modification of the ice machine. The water regulator valve
for the condenser continues to control the refrigeration
discharge pressure.
It is necessary to know the amount of heat rejection, and
pressure drop through the condenser and water valves
(inlet and outlet) when using a cooling tower on an ice
machine.
Water entering the condenser must not be lower than
37°F (3°C) or exceed 90°F (32°C).
Water flow through the condenser must not exceed 5
gal. (19 L) per minute.
Allow for a pressure drop of 7 psi (48 kPa) between the
condenser water inlet and the outlet of the ice machine.
Water exiting the condenser must not exceed 110°F
(43°C).
ICE MACHINE WATER USAGE
Series
Ice Machine
Potable Water
Gal/100Lbs Ice
Condenser
Gal/100Lbs Ice
RF0244 - RF0266 11.8
RFS0300 - RNS0308 12.0
RF0388 12.4
RF0399 12.5
RNS0600 12.0 109
RFS0650 12.0 73
RF0644 - RNS1000 12.0
RFS1200 12.0 118
RN1200 13.2 109
RFS1279R 12.0
RF2300 - RFS2300 12.0 138
Part Number 000007644 Rev 01 12/16 11
Section 2 Installation Instructions
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Water Temp
Min/Max
Water Pressure
Min/Max
Fitting/Min Tubing Size
Potable
Water Inlet
37°/90°F
(3°/32°C)
14/80 psi
(100/552 kPA)
3/8" FPT
Potable
Water Drain
--- --- 1/2" MPT
Condenser
Water Inlet
37°/90°F
(3°/32°C)
20/150 psi
(138/1034 kPA)
3/8" FPT
RF2300 only = 1/2" FPT
Condenser
Water Drain
--- --- 1/2" MPT
Bin Drain --- --- 3/4" FPT
Large Capacity Bin Drain --- --- 1" FPT
UNDERCOUNTER UNITS
ROUTE
DRAIN
TUBING TO
OPEN SITE
DRAIN
WATER SHUT-OFF VALVE
REQUIRED - ICE MAKING
WATER INLET TUBING 3/8"
MIN. I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
ICE MAKING
WATER INLET
TUBING 3/8" MIN.
I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
SEPARATE BIN AND ICE
MACHINE DRAINS ARE
REQUIRED
ROUTE DRAIN TUBING TO
OPEN SITE DRAIN
MODULAR UNITS
Typical Water Supply Drain Installation
12 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
Electrical Service
n
Warning
All wiring must conform to local, state and national
codes.
VOLTAGE
The maximum allowable voltage variation is ±10% of the
rated voltage at ice machine start-up (when the electrical
load is highest).
n
Warning
The ice machine must be grounded in accordance with
national and local electrical codes.
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
The ice machine must be grounded.
A separate fuse/circuit breaker must be provided for
each ice machine.
A qualified electrician must determine proper wire size
dependent upon location, materials used and length
of run (minimum circuit ampacity can be used to help
select the wire size).
The maximum allowable voltage variation is +/-10 of
the rated voltage at ice machine start-up (when the
electrical load is highest).
Check all ground screws in the control box and verify
they are tight before starting the ice machine.
Important
Observe correct polarity of incoming line voltage.
Incorrect polarity can lead to erratic ice machine
operation.
FUSE/CIRCUIT BREAKER
A dedicated circuit and a separate fuse/circuit breaker are
required for each ice machine.
GROUND FAULT CIRCUIT INTERRUPTER
We do not recommend the use of a GFCI/GFI circuit
protection with our equipment. If a GFCI/GFI is required
by code, use a GFCI/GFI breaker rather than outlet which is
more prone to intermittent nuisance trips than panel circuit
breakers.
MINIMUM POWER CORD SPECIFICATIONS
The wire size to the receptacle is dependent upon location,
materials used, length of run, etc., so it must be determined
by a qualified electrician. Local, state or national
requirements will supersede our minimum requirements.
FOR UNITED KINGDOM ONLY
As the colors of the wires in the mains lead of the
appliance may not correspond with the colored markings
identifying the terminals in your plug, proceed as follows:
The wire which is colored green and yellow must be
connected to the terminal in the plug which is marked
with the letter E or by the earth ground symbol or
colored green or green and yellow.
The wire colored blue must be connected to the
terminal which is marked with the letter N or colored
black.
The wire colored brown must be connected to the
terminal which is marked with the letter L or colored
red.
Part Number 000007644 Rev 01 12/16 13
Section 2 Installation Instructions
Maximum Breaker Size & Minimum Circuit Amperage Chart
Important
Due to continuous improvements, this information
is for reference only. Please refer to the ice machine
serial number tag to verify electrical data. Serial tag
information overrides information listed on this page.
Series Ice
Machine
Voltage
Phase
Cycle
Air-Cooled Water-Cooled QuietQube
Max
Fuse/
Circuit
Breaker
Min
Circuit
Amps
Total
Circuit
Amps
Max
Fuse/
Circuit
Breaker
Min
Circuit
Amps
Max
Fuse/
Circuit
Breaker
Total
Circuit
Amps
RF0244
115/1/60 15 Amp N/A 7.5 N/A N/A
230/1/50 10 Amp N/A 2.7 N/A N/A
RNS0244
115/1/60 15 Amp N/A 7.5 N/A N/A
230/1/50 10 Amp N/A 2.7 N/A N/A
RF0266
115/1/60 15 Amp N/A 7.5 N/A N/A
230/1/50 10 Amp N/A 2.7 N/A N/A
RF0385
115/1/60 15 Amp N/A 10.0 N/A N/A
230/1/50 10 Amp N/A 3.3 N/A N/A
RNS0385
115/1/60 15 Amp N/A 10.0 N/A N/A
230/1/50 10 Amp N/A 3.3 N/A N/A
RF0388
115/1/60 15 Amp N/A 10.0 N/A N/A
230/1/50 10 Amp N/A 3.3 N/A N/A
RF0399
115/1/60 15 Amp N/A 10.0 N/A N/A
230/1/50 10 Amp N/A 3.3 N/A N/A
RF0644 115/1/60 25 Amp N/A 13.5 N/A N/A
RFS0300 115/1/60 20 Amp 12.8 N/A N/A
RNS0300 115/1/60 20 Amp 12.8 N/A N/A
RNS0600
115/1/60 25 Amp 16.3 25 Amp 15.4
208-230/1/60 15 Amp 8.7 15 Amp 8.2
230/1/50 15 Amp 7.7 15 Amp 7.1
RFS0650
115/1/60 25 Amp 16.3 25 Amp 15.4
208-230/1/60 15 Amp 8.7 15 Amp 8.2
RNS1000
115/1/60 15 Amp 2.9
208-230/1/60 20 Amp 14.2 20 Amp 13.7 15 Amp 1.4
230/1/50 15 Amp 11.7 15 Amp 11.2
RF1200
RFS1200
208-230/1/60 20 Amp 12.5 20 Amp 12.5 15 Amp 1.4
230/1/50 10 Amp 1.4
RF2300
208-230/3/60 20 Amp 15.0 20 Amp 15.0
400-415/3/50 16 Amp 13.9 16 Amp 13.9
RFS2300
208-230/3/60 15 Amp 3.2
230/1/50 15 Amp 3.2
RFS1200R 208-230/1/60 15 Amp 1.4
RFS2300R 208-230/3/60 15 Amp 3.2
NOTE: Maximum allowable voltage variation at compressor start-up is ±10% of voltage listed above and on the
model/serial plate.
14 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
QUIETQUBE REMOTE CONDENSING UNIT
Condensing Unit Voltage/Phase/Cycle Maximum Fuse/Circuit Breaker Minimum Circuit Amps
RCU1075
208-230/60/1 15 15
208-230/60/3 15 15
208-230/50/1 15 15
RCU1098
208-230/60/1 15 15
208-230/60/3 15 15
RCU2375
208-230/60/1 15 15
208-230/60/3 15 15
208-230/50/1 15 15
Part Number 000007644 Rev 01 12/16 15
Section 2 Installation Instructions
Refrigeration System Installation
Remote Condensing Unit Only
QuietQube®
Ice Machine
Remote
Condensing Unit
Line Set*
RNS1000C
RFS1200C
RFS2300C
RCU1098
RCU1075
RCU2375
RC-21
RC-31
RC-51
*Line Set Suction Line Liquid Line
RC 21/31/51
5/8 inch
(15.9 mm)
3/8 inch
(9.5 mm)
Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on the
refrigeration system will be void if a new ice machine
head section is connected to pre-existing (used) tubing
or condensing units or vice versa.
USAGE WITH NONMANITOWOC CONDENSING UNITS
Manitowoc Remote Condensing Units are specifically
designed for usage with a QuietQube® Ice Machine Head
Section. Standard condensing units and Non-Manitowoc
condensing units are not approved for use with a
QuietQube® Ice Machine Head Section.
,
Caution
The 60-month compressor warranty (including the
24-month labor replacement warranty) will not
apply if the Manitowoc Ice Machine and Manitowoc
Remote Condensing Unit are not installed according
to specifications. This warranty also will not apply if
the refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice.
Factory Equipment Refrigeration Amounts
ICE MACHINE HEAD SECTION
Each ice machine condensing unit ships from the factory
with a R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice machine
indicates the refrigerant charge. The refrigerant charge
is sufficient to operate the ice machine in ambient
temperatures between -20°F (-28.9°C) and 120°F (48.9°C).
With line set lengths of up to 100 feet (30.5 m).
n
Warning
Potential Personal Injury Situation
The QuietQube Condensing Unit contains the
refrigerant charge. Installation and brazing of the line
sets must be performed by a properly trained and EPA-
certified refrigeration technician aware of the dangers
of dealing with refrigerant-charged equipment.
,
Caution
Never add more than nameplate charge to the
refrigeration system for any application.
REFRIGERATION LINE SETS/TRAP KIT
Refrigeration Rated Tubing and Trap Kits are shipped
capped with atmospheric pressure.
n
Warning
Installation of a QuietQube® Condensing Unit may
require the use of special equipment for placement.
Trained and qualified personnel are required for proper
rigging and lifting.
16 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
Refrigeration Line Set Installation
Remote Condensing Unit Only
GENERAL
Refrigeration line set installations consist of vertical and
horizontal line set distances between the ice machine and
the condensing unit. The following guidelines, drawings
and calculation methods must be followed to assure
proper oil return and remote condensing unit/ice machine
operation.
The refrigeration line set installer must be USA
Government-Environmental Protection Agency (EPA)
certified in proper refrigerant handling and servicing
procedures.
n
Warning
The QuietQube Condensing unit contains refrigerant
charge. The two refrigeration valves must remain closed
until proper installation of the line sets is completed.
n
Warning
Disconnect electrical power to the ice machine head
section and remote condensing unit before proceeding.
Step 1 Verify Ice Machine and Remote Condensing
Unit Locations Are Within Guidelines
Prior to installation of the ice machine head section and
remote condensing unit be sure that the distance between
them is within the line set routing guidelines outlined in
this manual.
Roof/Wall Penetration
If required, cut a 3-inch (76.2 mm) circular hole in the wall or
roof for routing of refrigeration tubing. A qualified person
must perform all roof penetrations.
Step 2 Route Refrigeration Tubing
Properly route refrigeration tubing between the ice
machine head section and the remote condensing unit.
A. LINE SET LENGTH
100 feet (30.5 m) Length: The maximum measured length
the line set can be.
The receiver is designed to hold a charge sufficient to
operate the ice machine in ambient temperatures between
-20°F (-28.9°C) and 120°F (48.9°C), with line set lengths of up
to 100 feet (30.5 m). The maximum amount of line set which
can be exposed on the rooftop is 25% of the total length of
the line set.
Important
QuietQube® ice machines will not function with line
sets greater than 100 feet (30.5 m). Do not attempt to
go beyond this distance and add refrigerant charge to
compensate!
B. LINE SET RISE OR DROP
35 ft. (10.7 m)
MAX.
DISTANCE
35 feet (10.7 m) Rise: The maximum distance the remote
condensing unit can be above the ice machine.
15 ft. (4.5 m)
MAX.
DISTANCE
15 feet (4.5 m) Drop: The maximum distance the remote
condensing unit can be below the ice machine.
Part Number 000007644 Rev 01 12/16 17
Section 2 Installation Instructions
C. SUCTION LINE OIL TRAPS
,
Caution
Do not form unwanted traps in refrigeration lines. Never
coil excess refrigeration tubing.
0 to 20 feet (0 to 6.1 m) Rise: No oil trap is required when
the condensing unit is located 20 feet (6.1 m) or less above
the ice machine head section.
21 to 35 feet (6.4 to 10.7 m) Rise: The suction line requires
an additional Oil Trap (“S” type) to be installed. Install
the trap as close as possible to midpoint between the
ice machine head section and remote condensing unit.
S-TrapKits are available from Manitowoc.
21 ft. (6.4 m)
OR MORE RISE
ADDITIONAL
TRAP KIT
REQUIRED
Service Loop
A service loop in the line set permits easy access to the ice
machine for cleaning and service.
A service loop is not considered an oil trap.
The service loop is not included when calculating
length, rise or drop of the tubing run.
Do not use hard rigid copper for the service loop.
,
Caution
If a line set has a rise followed by a drop, another
rise cannot be made. Likewise, if a line set has a drop
followed by a rise, another drop cannot be made.
Step 3 Lengthening or Reducing Line Set Lengths
,
Caution
Do not form unwanted traps in refrigeration lines. Never
coil excess refrigeration tubing.
When the line set requires shortening or lengthening, do
so before connecting the line set to the ice machine head
section or the remote condensing unit.
18 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
Step 4 Connecting the line set
To prevent oxidation of the copper, purge line set and
condensing unit with dry nitrogen while brazing.
A. Connect the Line Set to the Remote Condensing Unit
n
Warning
The QuietQube Condensing unit contains refrigerant
charge. The two refrigeration valves must remain closed
until proper installation of the line sets is completed.
The line set shut-off valves must remain closed and be
protected from heat during the brazing process. Wrap
the valves in a wet rag or other type of heat sink prior to
brazing. Cool braze joint with water immediately after
brazing to prevent heat migration to the valve.
SUCTION LINE
LIQUID LINE
MINIMIZE THE TIME THE
REFRIGERATION SYSTEM IS
EXPOSED TO THE ATMOSPHERE
(15 MINUTES MAXIMUM)
B. Connect the Line Set to the Ice Machine Head Section
n
Warning
The ice machine head section ships from the factory
pressurized with R404A refrigerant. Recover the
refrigerant from both suction and liquid line access
ports prior to cutting into refrigeration lines.
Cut the suction and liquid tubing with a tubing cutter,
leaving enough tubing to easily braze.
Connect the line set.
Cool braze joint with water immediately after brazing to
prevent heat migration.
Step 5 Pressure Test and Evacuate Line Set and Ice
Machine Head Section
Suction and liquid line set shutoff valves must remain
closed until pressure testing and evacuation are
complete.
Pressure testing and evacuation can be performed from
the ice machine head section or CVD condensing unit
shut-off valves.
Schrader valve core removal tools that allow for removal
and installation of the valve cores without removing
manifold gauge set hoses are recommended to
decrease the evacuation time.
Pressure test @ 150 psi (1000 kPa) for a minimum of
15minutes.
Minimum evacuation level is 500 microns.
Suction and liquid line shut-off valves
must remain closed until evacuation and
pressure testing are complete.
Part Number 000007644 Rev 01 12/16 19
Section 2 Installation Instructions
Step 6 Leak Check the Refrigeration System
Leak check the new line set connections at the ice machine
head section, condensing unit and S trap as well as all
factory joints throughout the entire system. Disconnect
power to the remote condensing unit. Place the rocker
switch into the ON position. This allows the low side and
high side pressures to equalize for leak checking. Place the
rocker switch in the OFF position. Connect power to the
remote condensing unit and allow system to pump down
after leak checking is complete.
Step 7 Open the Valves Prior to Starting the Ice
Machine
A. Slowly backseat (open-turn counterclockwise) the
suction line shutoff valve.
B. Slowly backseat (open-turn counterclockwise) the
liquid line shutoff valve.
Open suction and liquid line
shut-off valves
Open Valves
Important
All refrigeration valve caps must be reinstalled to
prevent future refrigeration leaks.
Verify O-ring in Schrader valve caps are intact and reinstall
on shutoff valves to prevent refrigerant leakage. Replace
shutoff valve access caps and torque to the following
specifications.
Torque Values
Stem 18-20 ft. lbs. (24.4-27.1 Nm)
Caps 12-15 ft. lbs. (16.3-20.3 Nm)
Schrader Core 1.5-3 in. lbs. (0.17-0.34 Nm)
Step 8 Insulation Requirements
To prevent condensation, the entire suction line must be
insulated. All insulation must be airtight and sealed at both
ends.
The following insulation requirements prevent
condensation at 90°F (32°C) ambient 90% Relative
Humidity. If higher humidity is expected, increase insulation
thickness.
The entire suction line set requires:
Suction Line Liquid Line
Min. Insulation
Thickness
5/8 in. (16 mm) 3/8 in. (10 mm)
1/2 in. (13 mm)
Suction Line
1/4 in. (7 mm)
Liquid Line
Important
To prevent condensation, the entire suction line must be
insulated. All insulation must be airtight and sealed at
both ends.
The minimum requirements are for conditions at or
below 90% humidity and 90°F (32°C) ambient. When
higher humidity will be experienced, or local code
requires, insulation wall thickness will need to be
increased.
20 Part Number 000007644 Rev 01 12/16
Installation Instructions Section 2
Installation Check List
All Manitowoc ice machines are factory-operated and adjusted before shipment. Adjustments and maintenance procedures
outlined in this manual are the responsibility of the owner/operator and are not covered by the warranty.
Is the ice machine level?
Is the ice machine and adapter (when used) secured to
the dispenser?
Have all of the electrical and water connections been
made?
Has the supply voltage been tested and checked
against the rating on the nameplate?
Is there proper clearance around the ice machine for air
circulation?
Is the ice machine grounded and polarity correct?
Has the ice machine been installed where ambient
temperatures will remain in the range of 50° - 110°F
(10° - 43°C)?
Has the ice machine been installed where the incoming
water temperature will remain in the range of 37° - 90°F
(3° - 32°C)?
Is there a separate drain for the water-cooled
condenser?
Is there a separate drain for the dispenser?
Is the ice making water turned on?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed regarding
maintenance and the use of Manitowoc Cleaner and
Sanitizer?
Has the owner/operator completed the warranty
registration card?
Has the ice machine and bin been sanitized?
Is the rocker switch set to ON?
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Manitowoc Ice RF / RFS / RNS Model Guide d'installation

Catégorie
Fabricants de glaçons
Taper
Guide d'installation