This instruction sheet provides you with information required to safely own and operate your Little Giant
pump. The instruction sheet primarily covers the standard models of each pump series. The form is appli-
cable to other models in the series not listed by catalog number in the replacement parts list section of the
instruction sheet. If the catalog number of your pump is not listed in the replacement parts list section, then
caution should be exercised when ordering replacement parts. Always give the catalog number of your
pump when ordering replacement parts.
The Little Giant unit you have purchased is of the highest quality workmanship and material It has been
engineered to give you long and reliable service. Little Giant pumps are carefully packaged, inspected
and tested to insured safe operation and delivery. When you receive your pump, examine it carefully to
determine that there are no broken or damaged parts that may have occurred during shipment. If damage
has occurred, make notation and notify the firm that you purchased the pump from. They will assist you in
replacement or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE
THE LITTLE GIANT PUMP. KNOW THE PUMP APPLICATION, LIMITATIONS, AND POTENTIAL
HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY GUIDELINES
1. Make certain that the unit is disconnected from the power source before attempting to service or
remove any component.
2. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explo-
sive atmospheres. Pump should only be used with liquids compatible with pump component materials.
3. Do not handle pump with wet hands or when standing on a wet or damp surface or in water.
4. This pump is supplied with a grounding conductor and/or grounding type attachment plug. To reduce the
risk of electric shock. be certain that it is connected to a properly grounded, grounding-type receptacle.
5. In any installation where property damage and/or personal injury might result from an inoperative or
leaking pump due to power outages, discharge line blockage, or any other reason, a backup system(s)
and/or alarm should be used.
6. Support pump and piping when assembling and when installed. Failure to do so may cause piping to
break, pump to fall, motor bearing failures, etc.
7. If pump is an oil-filled pump, the motor housing is filled with a dielectric lubricant at the factory for opti-
mum motor heat transfer and lifetime lubrication of the bearings. Use of any other lubricant could cause
damage and void the warranty. This lubricant is non-toxic; however, if it escapes the motor housing, it
should be removed from the surface quickly by placing newspapers or other absorbent material on the
water surface to soak it up, so aquatic life is undisturbed.
ELECTRICAL CONNECTIONS
1. Check the pump label for proper voltage required. Do not connect to voltage other than that shown.
2. If pump is supplied with a 3-prong electrical plug, the third prong is to ground the pump to prevent
possible electrical shock hazard. DO NOT REMOVE the third prong from the plug. A separate branch
circuit is recommended. Do not use an extension cord. Do not cut plug from the cord. If the plug is cut
or the cord is shortened, then this action will void the warranty.
3. If the cord is equipped with stripped lead wires, such as on 230V models, be sure that the lead wires
are connected to a power source correctly. The (green/yellow) wire is the ground. The (blue or white)
and the (brown or black) are live.
CONSULT INSTRUCTION SHEET ILLUSTRATIONS FOR PROPER ASSEMBLY AND DISASSEMBLY OF
YOUR LITTLE GIANT PUMP.
OPERATION
1. The pump must be run submerged. The pump can be placed on any of its sides. However, if the sur-
face is sandy or muddy, provide a smooth surface for the pump when the intake is on the bottom or
place on one of its other sides.
2. Do not attempt to restrict the intake side of these pumps. Restricting the intake may cause damage to the
seal and may starve the pump. If you require reduced flow rates, then place a valve on the discharge side
of the pump or if flexible vinyl tubing is used, a clamp can be used on the tubing to restrict the flow.
3. Do not let the unit run dry (without liquid). It is designed to be cooled by pumping fluid. You may dam-
age the seal and the motor may fail if the pump is allowed to run dry.
4. If the unit is going to be idle for a period of time, follow the cleaning instructions outlined in the next
section. Do not let the unit freeze in the wintertime. This may cause cracking or distortion that may
destroy the unit.
SERVICE INSTRUCTIONS
MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE POWER SOURCE BEFORE ATTEMPTING TO
SERVICE OR REMOVE ANY COMPONENT!
1. This unit is permanently lubricated. Oiling is not required. Do not, in any case, open the sealed portion
of the unit or remove housing screws.
2. Periodic cleaning of the pump parts will prolong the life and efficiency of the pump. Refer to the assem-
bly and disassembly of the pumping head.
3. First remove the two front screws (item 1) Do not remove other screws which may be exposed. You
can then remove the screen intake and volute plate. Make sure that the O-ring is removed with caution
to avoid damage to O-ring.
4. Lightly clean any corrosion or debris which may clog the impeller. Use a brush and penetrating oil and
lightly scrape to remove encrusted material.
5. Turn the impeller by hand to make sure it turns freely. Set pump down so the pump and impeller are
not touching anything. Plug the unit into GFCI circuit for 10 seconds to see if the impeller turns; a) If it is
rotating and GFCI did not trip, unplug unit and install parts in reverse order in which they were removed.
b) If it does not rotate, if pump is tripping circuit breakers, or not operating properly after cleaning, return
to Little Giant or its authorized service center. DO NOT attempt repairs yourself.
6. Be certain power cord is in good condition and contains no nicks or cuts.
F
INTRODUCTION
Elle concerne en particulier les modèles standard de chaque série ainsi que les modèles des séries non
listées par numéro de catalogue sur la liste des pièces de rechange. Si le numéro de catalogue de la
pompe achetée ne fait pas partie de la liste des pièces de rechange, certaines précautions seront à pren-
dre lors dos commandes de pièces de rechange. Ne pas oublier d’indiquer le numéro du catalogue sur
le bon de commande.
La qualité d’exécution et les matériaux du modèle Little Giant acheté sont parfaits. Cette pompe a été
conque pour fonctionner sans problèmes, de façon durable. Les pompes Little Giant ont été emballées
et testées avec soin pour procurer à l’acquéreur un fonctionnement et un rendement sûrs. A la réception,
veiller à examiner attentivement la pompe afin de s’assurer qu’aucune pièce n’a été endommagée pendant
le transport. Si tel n’est pas le cas, prendre note des dommages et aviser le distributeur chez qui la pompe
a été achetée afin de la faire réparer ou d’obtenir son remplacement.
LIRE ATTENTIVEMENT LE MODE D’EMPLOI AVANT L’INSTALLATION, L’UTILISATION OU L’ENTRETIEN
DE LA POMPE LITTLE GIANT. PRENDRE ATTENTIVEMENT CONNAISSANCE DES POSSIBILITES
D’UTILISATION, DES RESTRICTIONS ET DES DANGERS S’Y RATTACHANT. ASSURER SA PROPRE
PROTECTION ET CELLES DES AUTRES EN OBSERVANT TOUTES LES DIRECTIVES DE SECURITE.
LE NON-RESPECT DE CES DIRECTIVES POURRAIT ETRE LA CAUSE DE BLESSURES OU DE
DOMMAGES MATERIELS. CONSERVER LE MODE D’EMPLOI POUR UN USAGE ULTERIEUR.
DIRECTIVES DE SECURITE
1. Veiller à débrancher l’appareil de sa source d’alimentation électrique avant l’entretien ou la dépose
d’une ou de plusieurs piéces.
2. Ne pas pomper des fluides explosifs ou inflammables tels qu’essence, mazout, kérosène, etc. Ne pas
employer dans une atmosphère comportant des risques de déflagration. La pompe ne doit servir qu’à
pomper des liquides compatibles avec les matériaux utilisés pour la fabrication des éléments qui la
composent.
Model • Modèle • Modelo
P-AAA
Pump • Pompe • Bomba
PARTS LIST
LISTE DES PIÉCES
LISTA DE PARTES
3. Ne pas manipuler la pompe les mains humides, les pieds posés sur une surface mouillée ou humide,
ou les pieds dans l’eau.
4. Cette pompe est équipée d’un conducteur de mise à la terre et ou d’une fiche de branchement à prise
de terre. Pour réduire les risques d’électrocution, s’assurer qu’elle est bien raccordée à une prise de
courant appropriée comportant une borne de mise à la terre.
5. Dans le cas de toute installation où des dommages matériels ou des blessures pourraient survenir par
suite de l’emploi d’une pompe qui ne fonctionnerait pas ou qui fuirait à cause d’une panne de courant,
d’une canalisation de refoulement bouchée ou de toute autre raison, prévoir l’emploi de(s) dispositif(s)
de secours ou d’alarme voulu(s).
6. Veiller à bien étayer la pompe et la tuyauterie lors du montage et de la mise en place. Sinon, non
seulement les tuyaux risqueraient de se déchirer mais la pompe pourrait également faire défaut et les
roulements du moteur pourraient subir des dommages, etc.
7. Si la pompe est remplie d’huile. Ie carter est rempli d’huile diélectrique servant de caloporteur pour la
chaleur engendrée par le moteur et de lubrifiant pour les paliers. L’emploi d’un autre lubrifiant quel qu’il
soit pourrait endommager l’appareil et annuler la garantie. Bien que cette huile ne soit pas toxique, en
cas de fuite, I’enlever rapidement à l’aide de journaux posés rapidement à la surface de l’eau pour que
la vie aquatique ne soit pas perturbée.
CONNEXIONS ELECTRIOUES
1. Consulter l’étiquette de la pompe pour connaître la tension appropriée. Ne pas raccorder à une source
autre que la tension spécifiée.
2. Si la pompe est équipée d’une fiche d’aiimentation électrique à trois broches, la troisième est destinée
à raccorder la pompe à la terre pour éliminer les risques d’électrocution. NE PAS ENLEVER cette
troisième broche du cordon d’alimentation. Un circuit de branche séparé est recommandé. Ne pas
utiliser un prolongateur. Ne pas couper la fiche du cordon. Couper la fiche ou raccourcir le cordon
entraînera l’annulation de la garantie.
3. Si le cordon est muni de conducteurs codes à l’aide de rayures, comme pour les modèles en 230 volts,
s’assurer que ces fils sont correctement raccordés à la source d’alimentation électrique. Ainsi le fil vert/
jaune est prévu pour le retour à la terre alors que les deux autres (bleu ou blanc) sont sous tension.
LIRE ATTENTIVEMENT LE MODE D’EMPLOI AVANT LE MONTAGE OU LE DEMONTAGE DE LA
POMPE LITTLE GIANT.
FONCTIONNEMENT
1. La pompe doit être utilisée dans une application de type immergé. La pompe peut être posée sur
n’importe lequel de ses cinq côtés. Toutefois, si la surface est ensablée ou boueuse, placez la pompe
sur une surface lisse lorsque l’admission se fait par le dessous ou posez la pompe sur un de ses autres
côtés.
2. Ne pas laisser fonctionner la pompe à sec, ce qui pourrait endommager le joint et provoquer une
panne de moteur car elle est conçue pour être refroidie par le liquide pompé.
3. Do not let the unit run dry (without liquid). Il est conçu pour se refroidir en pompant un liquide. Vous pou-
vez endommager le joint et le moteur peut tomber en panne si vous laissez la pompe tourner à vide.
4. Si l’appareil doit rester inutilisé pendant un certain temps, suivez les instructions de nettoyage ci-des-
sous. Ne laissez pas l’appareil geler en hiver. Cela peut entraíner des fêlures ou des déformations qui
détruiraient l’appareil.
DIRECTIVES D’ENTRETIEN
VOTRE POMPE DEMANDERA TRÈS PEU D’ENTRETIEN. SI, POUR UNE RAISON QUELCONQUE, ELLE
NE PEUT PAS FONCTIONNER, SUIVEZ LES INSTRUCTIONS CI-DESSOUS!
1. Cette unité est lubrifiée en permanence. Il n’est pas nécessaire de la graisser. N’ouvrez jamais la partie
scellée de l’unité et n’enlevez jamais les vis du boîtier.
2. Le nettoyage périodique de la pompe augmentera sa durée de vie et son efficacité. Consultez la savoir
comment assembler et démonter la tête de pompage.
3. Retirez d’abord les deux vis frontales (pièce 1). Ne retirez aucune autre vis exposée. Vous pouvez
ensuite dégager l’entrée de grille et la plaque de la volute. Prenez des précautions lors du retrait du
joint torique afin de ne pas l’endommager.
4. Nettoyer délicatement toute trace de corrosion ou tout débris : ils peuvent bloquer la turbine. Utilisez
une brosse et de l’huile pénétrante et grattez lègérement.
5. Faire tourner la roue à la main pour s’assurer qu’elle tourne librement. Placer la pompe de telle manière
que la pompe et la roue à l’écart de tout ebjet. Pendant 10 secondes, brancher l’appareil dans un cir-
cuit muni d’un disjoncteur de fuite à la terre pour déterminer si la roue à aubes toune librement; a) Si
elle tourne bien et si le disjoncteur ne se déclenche pas, débrancher alors l’appareil et poser les pièces
dans l’ordre inverse de la dépose; b) Si elle ne tourne pas, si la pompe déclenche un court-circuit, ou
si elle ne fonctionne pas correctement malgré un nettoyage en règle, retourner l’appareil à la société
Little Giant ou à un service après-vente agréé. NE PAS essayer de faire las réparations vous-même.
6. S’assurer que le cordon électrique est en bon état et qu’il n’est pas coupé.
E
INTRODUCCION
Adjunta a su bomba Little Giant, se encuentra una hoja de instrucciones que le proporciona la informacion
necesaria para poseer y hacer funcionar sin peligro su bomba Little Giant. La hoja de instrucciones abarca
principalmente los modelos corrientes de cada serie de bombas. El formulario es aplicable a los demas
modelos de la serie, que no aparecen enunciados por número de catálogo en la seccion de la lista de
piezas de repuesto de la hoja de instrucciones. Si el número de catálogo de su bomba no aparece en la
seccion de la lista de piezas de repuesto, debe procederse con precaución al ordenar piezas de repuesto.
Al ordenar piezas de repuesto, indique siempre el número de catálogo de su bomba.
Los materiales y la mano de obra de la unidad Little Giant que usted ha adquirido, son óptimos. Se ha
fabricado para servirle sin tropiezos durante largo tiempo. Las bombas Little Giant se embalan, inspec-
cionan y prueban cuidadosamente, para garantizar un funcionamiento y una entrega sin peligro. Cuando
reciba su bomba, examinela cuidadosamente, para veriticar que durante el transporte no se haya roto ni
averiado ninguna pieza. Si encuentra algun daño, tome nota de él, e informe a la firma de la cual adquirió
la bomba; ella le ayudará a cambiarla o repararla, si es necesario.
ITEM NO. PART NO. DESCRIPTION QTY.
1 902406 Screw, 8-32 x 5/8" 2
2 123145 Screen 1
3 123150 Plate 1
4 942020 O-Ring 1
5 123030 Impeller 1
6 943076 Elbow 1
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-[email protected]
LIMITED WARRANTY
Your Little Giant product is guaranteed to be in perfect condition when it leaves our Factory. It is warranted against
defective materials and workmanship for a period of 12 months (90 day warranty on Models: 1-AA-OM, GKPK-SC,
PP-1, PPS-1, PP-12, PPS-12, PP-230 and Cooler King) from date of purchase by the user. No warranty on brush wear
in Model 35-OM and impeller or cam in Models PP-1, PP-12, and PP-230.
Any product that should fail for either of the above two reasons and is still within the warranty period will be repaired
or replaced at the option of Little Giant as the sole remedy of buyer. For our customers in the CONTINENTAL UNITED
STATES: Please return the defective unit, postage paid, to the factory at 301 North MacArthur Blvd., Oklahoma City,
OK 73127-6616. All defective product returned under warranty will be fully inspected to determine the cause of
failure before warranty is approved.
For our customers located elsewhere; it is not economical, due to duties and freight, to return the pump to the factory
for inspection. Please return the defective unit to any authorized distributor or dealer with a brief written explanation
of the problem. If there are no apparent signs of customer abuse, unit will be repaired or replaced. If dispute arises
over replacement of the pump, the distributor or dealer is to segregate such items and hold for inspection by a
representative of Franklin Electric Co., Inc. or notify factory with details of the problem for factory disposition and
settlement of warranty claim.
DISCLAIMER: THE FOREGOING WARRANTY IS AN EXCLUSIVE WARRANTY IN LIEU OF ANY OTHER EXPRESS
WARRANTIES. ANY IMPLIED WARRANTIES (INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) TO THE EXTENT EITHER APPLIES
TO A PUMP SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESS WARRANTIES GIVEN
ABOVE.
Warranty will be VOID if any of the following conditions are found:
1. Sealed motor housing opened.
2. Product connected to voltage other than indicated on nameplate.
3. Cord cut off to a length less than three feet.
4. Pump allowed to operate dry (fluid supply cut off).
5. Pump used to circulate anything other than fresh water, light oils, or other mild liquids at approximately room
temperature.
6. Product abuse by customer.
Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties,
do not constitute warranties, shall not be relied upon by the user and are not part of the contract for sale. Seller’s
and manufacturer’s only obligation, and buyer’s only remedy, shall be the replacement and/or repair by the manu-
facturer of the product as described above. NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR
ANY INJURY, LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED
TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST SALES, INJURY TO PERSON OR
PROPERTY, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS), ARISING OUT OF THE USE OR THE IN-
ABILITY TO USE THE PRODUCT AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO
IT. Before using, the user shall determine the suitability of the product for the intended use, and user assumes all
risk and liability whatsoever in connection therewith.
Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limi-
tation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from state to state and
country to country.
The National Electric Code (in the USA) and similar codes in other countries require a Ground Fault Circuit Interrupter
(GFCI) to be installed in the branch circuit supplying fountain equipment rated above 15 volts. 115 volt GFCI’s (with
various cord lengths) are in stock, and we recommend each pump be used with a GFCI.
GARANTIE LIMITÉE
La présente garantit que votre pompe Little Giant est en parfaite condition à sa sortie de l’usine. La pompe est ga-
rantie contre tout défaut de matériau ou de fabrication pendant une période de 12 mois (90 jours pour les Modèles:
1-AA-OM, GKPK-SC, PP-1, PPS-1, PP-12, PPS-12, PP-230 et Cooler King) à partir de la date d’achat initial. L’usure
des balais sur le modèle 35-OM ainsi que les dommages au rotor ou à la came sur les modèles PP-1, PP-12 et PP-
230 ne sont pas couverts par la présente garantie.
Tout produit encore garanti qui serait défectueux pour l’une des deux raisons sus-mentionnées sera réparé ou
remplacé à la discrétion du fabricant. L’acheteur n’aura pas d’autre recours. Pour nos clients aux ÉTATS-UNIS
(territoire continental seulement): Veuillez retourner l’article défectueux suffisamment affranchi à l’usine à l’adresse
suivante 301 North MacArthur Blvd., Oklahoma City, OK 73127-6616. Tous les produits garantis retournés feront
l’objet d’une inspection détaillée afin de déterminer si la défectuosité est couverte par la garantie. Pour les clients à
l’extérieur des États-Unis : étant donné les frais de douane et de transport, il n’est pas économique de retourner la
pompe à l’usine pour inspection. Expédier la pompe ainsi qu’une brève description du problème à tout distributeur
ou détaillant autorisé. Si elle ne présente aucun signe apparent d’une mauvaise utilisation, elle sera remplacée ou
réparée. S’il y a conflit sur la nécessité de remplacer la pompe, le distributeur ou le détaillant devra garder celle-ci
et, soit la fera inspecter par un représentant de Franklin Electric Co., Inc., soit avisera l’usine du problème afin de
connaître la décision de celle-ci et le règlement de la réclamation.
DÉNÉGATION: LA GARANTIE ÉNONCÉE DANS LES PRÉSENTES EST EXCLUSIVE ET REMPLACE TOUTE
AUTRE GARANTIE EXPRESSE OU IMPLICITE; CELA COMPORTE, MAIS NON EXCLUSIVEMENT, TOUTE
GARANTIE IMPLICITE D’APTITUDE À LA COMMERCIALISATION OU D’APTITUDE PARTICULIÈRE, POUVANT
S’APPLIQUER À UNE POMPE LITTLE GIANT. DE PLUS, ELLE NE S’APPLIQUE QUE DURANT LA PÉRIODE DE
COUVERTURE PRÉCISÉE CI-DEVANT.
La présente garantie sera ANNULÉE si:
1. Le boîtier scellé du moteur a été ouvert;
2. Le branchement à une tension autre que celle indiquée sur la plaque du fabricant a été effectué;
3. Le fil d’alimentation a été coupé à une longueur inférieure à 0,91 m (trois pieds);
4. La pompe a tourné à vide (l’alimentation en liquide a été coupée);
5. La pompe a été utilisée pour faire circuler des liquides autres que de l’eau fraîche, des huiles légères ou d’autres
liquides non corrosifs et ce, à la température ambiante;
6. La pompe a été mal utilisée.
Toute déclaration sur la pompe faite oralement par le vendeur, le fabricant, le représentant ou par toute autre partie
ne constitue pas une garantie et, par conséquent, ne peut servir à l’utilisateur. De plus, une telle déclaration ne peut,
en aucun cas, faire partie du contrat de vente. L’unique obligation du vendeur et du fabricant, et l’unique recours
de l’acheteur, est le remplacement ou la réparation de la pompe selon les modalités décrites précédemment. NI
LE VENDEUR NI LE FABRICANT NE PEUVENT ÊTRE TENUS RESPONSABLES DE TOUTE BLESSURE, TOUTE
PERTE, OU TOUT DOMMAGE DIRECT, INDIRECT OU ACCESSOIRE (INCLUANT, MAIS NON EXCLUSIVEMENT,
LES VENTES OU PROFITS PERDUS, LES ATTEINTES AUX PERSONNES OU À LA PROPRIÉTÉ OU TOUTE AUTRE
PERTE INDIRECTE OU ACCESSOIRE) RÉSULTANT DE L’UTILISATION OU DE L’INCAPACITÉ D’UTILISATION DE LA
POMPE, ET L’ACHETEUR CONVIENT QU’IL NE DISPOSE D’AUCUN AUTRE RECOURS. L’acheteur doit s’assurer que
la pompe convient à l’usage projeté; il assume aussi tout risque et toute responsabilité relativement à cet usage.
Certaines juridictions ne permettent pas la limitation de la durée d’une garantie ou l’exclusion ou la limitation de
responsabilité pour des dommages indirects ou accessoires. Par conséquent, il est possible que la limitation ou
l’exclusion indiquée précédemment puisse ne pas être applicable. Cette garantie vous donne des droits particuliers
et peut-être d’autres, dépendamment des juridictions en vigueur.
Le code national de l’électricité et autres codes semblables d’autres pays exigent l’installation d’un interrupteur avec
mise à la terre (GFI) sur le circuit d’alimentation de la fontaine pour toute installation dont la tension est supérieure
à 15 volts. Nous offrons de tels interrupteurs (avec différentes longueurs de fil) et nous recommandons que chaque
pompe soit reliée à un interrupteur de ce type.
GARANTIA LIMITADA
El producto que Little Giant le ofrece está garantizado a estar en perfectas condiciones al momento de salir de la
fábrica. El producto está garantizado contra materiales y fabricación defectuosa por un período de 12 meses (una
garantía de 90 días para los Modelos: 1-AA-OM, GKPK-SC, PP-1, PPS-1, PP-12, PPS-12, PP-230 y Cooler King) desde
la fecha en la cual fue comprada por el usuario. No hay garantía contra el gasto del cepillo del Modelo 35-OM e
impulsor o leva en los Modelos PP-1, PP12 y PP-230.
Cualquier producto que falle por alguna de las dos razones anteriores y que esté dentro del período de garantía
será reparado o reemplazado a opción de Little Giant y éste será el único remedio del comprador. Para nuestros
clientes en los ESTADOS UNIDOS CONTINENTALES: Por favor, devolver la unidad defectuosa, con el porte pagado,
a la fábrica en 301 North MacArthur Blvd., Oklahoma City, OK 73127-6616. Todo producto defectuoso devuelto bajo
la garantía será cuidadosamente inspeccionado para determinar la causa de la falla antes de aprobar la garantía.
Para nuestros clientes ubicados en otros lugares; no es económico devolver la bomba a la fábrica para que ésta sea
inspeccionada, debido a los impuestos y al flete. Por favor, devuelva la unidad defectuosa a cualquier distribuidor o
vendedor autorizado con una breve explicación por escrito del problema. Si no existen señas aparentes de abuso
por parte del cliente, la unidad será reemplazada o reparada. Si se produce una disputa sobre el reemplazo de la
bomba, el distribuidor o vendedor debe separar los artículos y retenerlos para que sean inspeccionados por un
representante de Franklin Electric Co., Inc. o avisarle a la fábrica de los detalles del problema para que la fábrica
disponga de las acciones necesarias y resuelva el reclamo de la garantía.
DESAUTORIZACION: LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQUIER
OTRA GARANTIA EXPRESA. CUALQUIER GARANTIA IMPLICADA (INCLUYENDO PERO NO LIMITADO A
CUALQUIER GARANTIA IMPLICADA DE COMERCIALIZACION O APTITUD PARA PROPOSITO PARTICULAR)
EN LA MEDIDA EN QUE SE PUEDA APLICAR A UNA BOMBA, QUEDARA LIMITADA EN DURACION A LOS
PERIODOS DE GARANTIAS PROPORCIONADOS ANTERIORMENTE.
La garantía será declarada NULA si se encuentran cualesquiera de las siguientes condiciones:
1. El alojamiento sellado del motor abierto.
2. El producto conectado a un voltaje que no es el indicado en la placa principal.
3. El cable cortado a menos de tres pies (0,91 m.).
4. Se permitió que la bomba opere en seco (envío de fluido cortado).
5. La bomba empleada para hacer circular cualquier otra sustancia que no sea agua fresca, aceites livianos u otros
líquidos livianos aproximadamente a temperatura ambiente.
6. Abuso del producto por parte del cliente.
Cualquier declaración oral acerca del producto hecha por el vendedor, fabricante, representantes o cualquiera de las
partes, no constituyen garantías, el usuario no debe confiarse de ellas, y no forman parte del contrato de compra-
venta. La única obligación del vendedor y del fabricante y el único remedio para el comprador, será la reposición y/o
reparación del producto por parte del fabricante bajo las condiciones descritas anteriormente. NI EL VENDEDOR NI
EL FABRICANTE SE HACEN RESPONSABLES DE NINGUNA LESION, PERDIDA O DAÑO, DIRECTO, INCIDENTAL
O CONSECUENTE (INCLUYENDO, PERO SIN LIMITARSE A, DAÑOS INCIDENTALES O CONSECUENTES DEBIDO
A GANANCIAS PERDIDAS, VENTAS PERDIDAS, DAÑOS A PERSONAS O PROPIEDADES O CUALQUIER OTRA
PERDIDA INCIDENTAL O CONSECUENTE), QUE RESULTE DEL USO O DE LA IMPOSIBILIDAD DEL USO DEL
PRODUCTO, Y EL COMPRADOR ACUERDA QUE NO EXISTE OTRO REMEDIO DISPONIBLE PARA EL. Antes de
usar, el usuario debe determinar si el producto se adapta al uso deseado, y el usuario asume todos los riesgos y
responsabilidades en relación a ello.
Algunos estados y países no permiten limitaciones sobre la duración de una garantía implícita o la exclusión o
limitación de daños incidentales o consecuentes, de manera que las limitaciones o exclusiones anteriores podrían
no tener aplicación en su caso. Esta garantía le da derechos legales específicos, y usted podría disponer también
de otros derechos que varían de un estado a otro y de un país a otro.
El Código Eléctrico Nacional (en los Estados Unidos) y códigos similares en otros países requieren un Interruptor
de circuito de falla de conexión a tierra (GFCI) para ser instalado en el circuito secundario que suministra equipo de
fuente calibrado por encima de 15 voltios. En el almacén se encuentran GFCI de 115 voltios (con varias longitudes
de cable), y recomendamos que cada bomba sea usada con un GFCI.
LEA CUIDADOSAMENTE LAS INSTRUCCIONES, ANTES DE INTENTAR INSTALAR, HACER
FUNCIONAR O REPARAR LA BOMBA LITTLE GIANT. CONOZCA LOS USOS, LIMITACIONES Y
PELIGROS POTENCIALES DE LA BOMBA. PROTEJASE Y PROTEJA A LOS DEMAS, OBSERVANDO
TODAS LAS NORMAS DE SEGURIDAD. Sl NO SE OBEDECEN LAS INSTRUCCIONES, PUEDEN
PRODUCIRSE LESIONES, DAÑOS MATERIALES O AMBOS. CONSERVE LAS INSTRUCCIONES
PARA CONSULTARLAS EN EL FUTURO.
NORMAS DE SEGURIDAD
1. Cerciórese de que la unidad se encuentra desconectada de la fuente de electricidad, antes de tratar
de reparar o quitar cualquier pieza.
2. No utilice la bomba para bombear líquidos combustibles o explosivos, tales como gasolina, petróleo
combustible, kerosene, etc. No la utilice en ambientes explosivos. La bomba solamente debe utilizarse
en líquidos compatibles con los materiales de sus elementos integrantes.
3. No manipule la bomba con las manos mojadas, ni mientras se encuentre en una superficie mojada o
huímeda o entre el agua.
4. Esta bomba está dotada de un cable de puesta a tierra, un enchufe tomacorriente de puesta a tierra o
ambas cosas. Para reducir el riesgo de choque eléctrico, cerciórese de que se encuentre conectada
a un receptáculo de puesta a tierra, debidamente puesto a tierra.
5. En cualquier instalación en la cual puedan producirse daños materiales/o lesiones personales causa-
dos por bombas que no funcionan o tienen escapes, debido a interrupciones del servicio eléctrico,
a obstrucciones de ia tuberéa de descarga o a cualquier otra razon debe utilizarse un sistema de
seguridad, una alarma o ambos.
6. Sostenga la bomba y la tubería durante el ensamblaje y la instalacion. La falta de soporte puede oca-
sionar roturas de la tubería, caIídas de la bomba, fallas de los cojinetes del motor, etc.
7. Si la bomba es una bomba llena de aceite, la caja del motor viene de fábrica llena de un lubricante
dieléctrico, para proporcionar una termotransferencia óptima del motor y una lubricación permanente
de los cojinetes. El uso de cualquier otro lubricante podría causar averías y anular la garantía. Este
lubricante no es tóxico; no obstante, si escapa de la caja del motor, puede quitarse rápidamente de la
superficie del agua, colocando sobre ella toallas de papel u otro material absorbente para embeberlo,
con el fin de no perturbar la vida acuática.
CONEXIONES ELECTRICAS
1. Consulte el rótulo de la bomba, para conocer el voltaje adecuado que se requiere. No la conecte a un
voltaje distinto del indicado.
2. Si la bomba está dotada de un enchufe eléctrico de tres dientes, el tercer diente es para ponerla a
tierra, con el fin de prevenir el peligro de posibles choques eléctricos. NO QUITE el tercer diente del
enchufe. Se recomienda un circuito de ramal independiente. No utilice cables de extensión. No corte
el enchufe del cable. Si se corta el enchufe o se acorta el cable, la garantiá será nula.
3. Si el cable viene dotado de hilos conductores forrados, como ocurre en los modelos de 230 voltios,
cerciórese de que los hilos conductores se encuentren conectados correctamente a una fuente de
electricidad. El hilo verde o amarillo, es el de puesta a tierra; el hilo azul o blanco y el marrón o negro,
son hilos con corriente.
CONSULTE LAS ILUSTRACIONES DE LA HOJA DE INSTRUCCIONES, PARA MONTAR Y DESMONTAR
CORRECTAMENTE SU BOMBA LITTLE GIANT.
FUNCIONAMIENTO
1. La bomba debe hacerse funcionar cuando esté sumergida. La bomba puede ser colocada sobre
cualquiera de sus lados. Sin embargo, si la superficie es arenosa o lodosa, proporcione una superficie
lisa para la bomba cuando la entrada está abajo o colóquela sobre uno de sus otros lados.
2. No permita que la unidad funcione en seco. Está diseñada para que la enfríen los liquidos bombea-
dos. Si se permite que la bomba funcione en seco, puede estropearse el obturador y el motor puede
caerse.
3. No deje que la unidad en operacin se quede sin agua. Esta diseñada para ser enfriada por medio del
bombeo de liquido. Usted puede dañar el sello y el motor puede fallar si se permite que la bomba
opere sin agua.
4. Si la unidad se mantiene sin funcionar por un período de tiempo largo, siga las instrucciones de limp-
ieza descritas en la próxima sección. No permita que la unidad se congele en invierno. Esto puede
causar agrietamiento o deformaciones, lo cual puede dest ruir la unidad.
INSTRUCCIONES DE SERVICIO
¡ASEGURESE DE QUE LA UNIDAD ESTE DESCONECTADA DE LA FUENTA DE ALIMENTACION
ELECTRICA ANTES DE INTENTAR PRESTAR SERVICIO A LA UNIDAD O QUITAR CUALQUIER
COMPONENTE DE ELLA!
1. Esta unidad se encuentra lubricada permanentemente. No se requiere lubricación. Jamás, en ningún
caso, abra la parte de la unidad que está sellada o retire los tornillos de la caja.
2. Una limpieza periódica de las piezas de la bomba prolongará la vida y eficiencia de la bomba. Vea
para montar y desmontar la cabeza de bombeo.
3. Primero quite los tornillos del frente (artículo 1). No quite ningún otro tornillo que esté expuesto. Usted
puede quitar la malla de entrada y la placa de la voluta. Asegúrese de que la junta tórica se quite con
cuidado para evitar daño a la junta tórica.
4. Limpie levemente cualquier corrosión o restos que puedan atascar el impulsor. Use un cepillo y pen-
etrando el aceite y ligeramente raspado para quitar el material incrustado.
5. Dé vuelta manualmente a la rueda móvil para verificar que gire libremente. Coloque la bomba de
manera que usted no la toque y que la rueda móvil no esté tocando nada. Enchufe la unidad en un cir-
cuito GFCI durante 10 segundos, para ver si la rueda móvil gira: a) si gira y el GFCI no se desconecta,
desenchufe la unidad e instale las piezas en un orden inverso a aquél en el cual se quitaron. b) Si
no rota, si la bomba desconecta los automáticos o no funciona debidamente después de la limpieza,
devuélvala a Little Giant o a su centro de reparaciòn autorizado. NO intente hacer usted mismo las
raparaciones.
6. Cerciórese de que el cable eléctrico se encuentre en buen estado y no tenga muescas ni cortes.
Form 994626 - 10/2007
© 2007 Franklin Electric Co., Inc.
Little Giant® is a registered trademark of Franklin Electric Co., Inc.
For parts or repair, please contact . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
For technical assistance, please contact . . . . . . . . . . . . . . . 1.888.956.0000
Pour des parties ou la réparation,
entrez s’il vous plaît en contact . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
Pour l’aide technique, entrez s’il vous plaît en contact . . . . 1.888.956.0000
Para partes o la reparación,
por favor póngase en contacto . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
Para la ayuda técnica, por favor póngase en contacto . . . . 1.888.956.0000
www.LittleGiantPump.com
  • Page 1 1
  • Page 2 2

Little GIANT 523003 Mode d'emploi

Taper
Mode d'emploi