17
Gas Connection
WARNING: Before starting any work related with gas installation, turn off
gas supply. Risk of explosion.
1. Before your appliance is connected to the gas supply, ensure that
the gas category and pressure specications shown in the data plate
corresponds with your gas supply. If necessary call authorized service for
adjusting to gas category.
2. This appliance shall be installed in accordance with the regulations
in force and only used in a well ventilated space. Read the instructions
before installing or using this appliance. In the interest of safety this
appliances must be installed and / or serviced by a competent person as
stated in the gas safety regulations current editions.
3. The appliance must not be installed in a room without a window or
other controllable opening. If is installed in a room without a door which
opens directly to the outside, a permanent opening is required. The air
circulation should be 2 m³/h per kW of burners.
4. The gas connection should be performed from the right or left. For
this reason, change the hose nozzle, plug and the seals.
5. Please use exible hose for gas connection.
6. If you make a connection with a exible metal hose, locate a seal
between the main gas pipes.
7. The inner diameter of the exible hose, which the butane hose nozzle
is connected, should be 6 mm for the house-type gas tubes. The inner
diameter of the exible hose, which the natural hose nozzle is connected,
should be 15 mm.The hose should tightly be tted to the hose nozzle
by squeezing with a clamp. The hose should be replaced before its last
expiry date.
8. CAUTION: Make the oven connection to the gas inlet valve, the hose
length must be short and be sure that there is no leakage. The exible
hose used should not be longer than 125 cm for safety.
9. Re-inspect the gas connection.
10. When placing your oven to its location, ensure that it is at the counter
level. Bring it to the counter level by adjusting the feet if necessary.