Ohaus OHA-30134157 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

Frontier
TM
Centrifuge FC5306
Instruction Manual
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
TABLE OF CONTENTS
1. INTRODUCTION ....................................................................................... 1
1.1 Safety measures ............................................................................... 1
2. INSTALLATION ......................................................................................... 3
2.1 Package contents .............................................................................. 3
2.2 Replacement or Installation of Rotor ................................................. 4
2.3 Power On .......................................................................................... 5
1.4 Preparation for Centrifugation ........................................................... 5
2.5 Centrifugation (Running) ................................................................... 5
3. SPECIAL ATTENTION .............................................................................. 6
3.1 Power supply ..................................................................................... 6
3.2 Use and maintenance ....................................................................... 6
4. SPECIFICATIONS .................................................................................... 7
5. COMPLIANCE ........................................................................................... 8
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Frontier
TM
FC5306 EN-1
1. INTRODUCTION
Thank you for choosing this OHAUS product.
Please read the manual completely before using the Frontier
TM
FC5306 to
avoid incorrect operation.
You will find much helpful functionality in Frontier
TM
5000 series centrifuge. A
few of the many existing features for Frontier
TM
FC5306 are:
Small and exquisite body, one-key operation
Convenient and quick installation and replacement of rotor without need of
using tool
Rotor will immediately stop running if lid is opened during operation
Desktop power adapter is applicable to 100-240V AC power supply
Elaborate product with low noise and long service time
1.1 Safety measures
CAUTION: Read all safety warnings before installing, making
connections, or servicing this equipment. Failure to comply with
these warnings could result in personal injury and/or property
damage. Retain all instructions for future reference.
Measures for your protection
Never work in an environment subject to explosion hazards!
The housing of the instru¬ment is not gas tight. (explosion
hazard due to spark formation, corrosion caused by the ingress
of gases)
When using chemicals and solvents, comply with the
instructions of the producer and the general lab safety rules.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
EN-2 Frontier
TM
FC5306
Measures for operational safety
Do not lean on the centrifuge.
Do not stay within the clearance envelope longer than necessary for
operational reasons.
Do not deposit any potentially hazardous materials within the clearance
envelope.
Do not unscrew the two halves of the housing.
Dry off any liquid spills immediately! The instrument is not watertight.
Verify that the AC adapter’s input voltage range and plug type are
compatible with the local AC power to be used.
Do not position the equipment such that it is difficult to disconnect the AC
adapter from the power receptacle.
Make sure that the power cord does not pose a potential obstacle or
tripping hazard.
The equipment is for indoor use only. Use the equipment only in dry
locations.
Use only approved accessories and peripherals.
Operate the equipment only under ambient conditions specified in these
instructions.
Disconnect the equipment from the power supply when cleaning.
Do not operate the equipment in hazardous or unstable environments.
Service should only be performed by authorized personnel.
Exclude the following environmental influences:
Powerful vibrations
Direct sunlight
Atmospheric humidity greater than 80%
Corrosive gases present
Temperatures below 5 °C and above 40 °C
Powerful electric or magnetic fields
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Frontier
TM
FC5306 EN-3
2. INSTALLATION
Carefully unpack the box.
2.1 Package contents
The model Frontier
TM
FC5306 has the following items:
Frontier
TM
FC5306
Photo
Units
Frontier
TM
FC5306 main
machine
1 set
Angle rotor ( 8 x 1,5/2ml)
1 set
4 x 0.2ml rectangle rotor for
PCR 8-tube bank
1 set
Dedicated DC24V power
adapter
1 set
Eight 0.5 ml adapters and
eight 0.2 ml adapters
8 x 2 units
Manual
1 set
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
EN-4 Frontier
TM
FC5306
2.2 Replacement or Installation of Rotor
1. When the machine is delivered from the factory, the seizing shaft sleeve
and angle rotor are firmly fixed on the shaft of the drive motor.
2. If it is necessary to dismantle an installed rotor, the user should hold the
outside edge of the rotor, and push the protruding clamp towards its
center with two thumbs, then lift the rotor upwards.
3. To reinstall rotor, align the oval hole of rotor over the clamp, then gently
press down the rotor until the clamp clicks into place.
角转头
电机轴套
Angle Rotor
Motor Shaft Sleeve
Clamp
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Frontier
TM
FC5306 EN-5
2.3 Power On
1. With the power switch on the back of this machine OFF.
2. Connect the output end of the adapter to the power socket on the back of
the machine, and then plug the unit to a power source.
1.4 Preparation for Centrifugation
1. Open the transparent lid (see photo below) and properly add load in a
balanced manner (refer to section “3.2 use and maintenance”).
2. Close the lid then press the power switch on the back of this machine to
ON (note: The rotor will not run as long as the lid is open).
2.5 Centrifugation (Running)
1. After the lid is closed and the machine switched on, the rotor will
automatically start running with its speed increasing to the rated speed,
and then it will run stably.
2. Open the lid when the requirement of centrifugation is met, the rotor will
immediately slow down to a complete stop.
3. It is unnecessary to turn off power if another centrifugation is required.
4. Turn off and unplug the machine when all centrifugation work is completed
or when not in use.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
EN-6 Frontier
TM
FC5306
3. SPECIAL ATTENTION
3.1 Power supply
1. The power supply to this machine must be realized through the adapter
provided together with the machine. The AC plug of adapter should not be
connected with three-phase power source.
2. Don’t insert or disconnect the power plug of the adapter with wet hand.
Don’t forcibly pull the cable to disconnect the power plug.
3.2 Use and maintenance
1. Prepare the micro burette of standard specification with hinged cover for
centrifugation. It is only allowed to add sample till approx. 70% of nominal
capacity at most. Visually check balance during adding of sample. Don’t
detach any poisonous or infectious biological sample. Don’t detach
flammable or explosive chemical sample.
2. The centrifugal tubes with sample must be symmetrically placed into the
centrifugal tube holes of the rotor to keep the rotor balanced.
3. When the rotor is installed or replaced, excessive sidewise force should
be avoided to prevent its deformation and bending. If the seizing shaft
sleeve around the motor shaft is a bit loose, it is necessary to fasten the
M3 set screw again.
4. Do not use broken or deformed rotor.
5. During daily cleaning and maintenance, the machine should be wiped with
clean water or neutral detergent, and be dried through natural ventilation.
6. During use, attention should be paid to symmetrical and horizontal
placement of centrifugal tubes.
WARNING: Disconnect the AC adapter from the AC power
supply and the equipment before cleaning. Do not allow liquids
to enter the AC adapter or the equipment.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Frontier
TM
FC5306 EN-7
4. SPECIFICATIONS
The technical data is valid under the following ambient conditions:
Operating temperature: 5°C to 40°C
Relative humidity: 20% to 85% relative humidity, non-condensing
Height above sea level: Up to 2000 m
Pollution degree: 2
Installation category: II
Main supply voltage fluctuations: up to ± 10% of the nominal voltage
Model
Frontier Mini CentrifugeFC5306
Rotor
Angle Rotor
Tube Bank Rotor
Rotating Speed Scope
6000 rpm ± 5%
Centrifugal Force
2000 g ± 10%
Rotating Direction
Counter clockwise
Max Capacity
8 x 1.5 ml / 2 ml
4 x 0.2 ml-PCR 8-tube
bank
or 32 x 0.2 ml single
centrifugal tube
Adapter
0.2 ml / 0.5 ml
-
Accelerating Time
2 s
Decelerating Time
3 s
Drive Mode and Motor
Direct drive, with low noise attributable to rolling bearing
Power Supply
Input: 100-240V ~ 50/60Hz 1.5A
Output: 24V 2.0A
Dimensions (W × D × H)
5.9 × 6.6 × 5.0 in. / 150 × 168 × 128 mm
Net Weight
2.316 lb / 1.05 Kg (including free-load angle rotor)
Shipping Dimensions
(W × D × H)
8.5 × 12.0 × 7.6 in. / 216 × 305 × 194 mm
Shipping Weight
4.079 lb / 1.85 Kg
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
EN-8 Frontier
TM
FC5306
5. COMPLIANCE
Compliance to the following standards is indicated by the corresponding mark
on the product.
Marking
Standard
This product conforms to the EMC directive 2014/30/EU and the
Low Voltage Directive 2014/35/EU. The complete Declaration of
Conformity is available online at
www.ohaus.com/ce.
Disposal
In conformance with the European Directive 2002/96/EC on
Waste Electrical and Electronic Equipment (WEEE) this device
may not be disposed of in domestic waste. This also applies to
countries outside the EU, per their specific requirements.
Please dispose of this product in accordance with local
regulations at the collecting point specified for electrical and
electronic equipment.
If you have any questions, please contact the responsible
authority or the distributor from which you purchased this
device.
Should this device be passed on to other parties (for private or
professional use), the content of this regulation must also be
related.
For disposal instructions in Europe, refer to
www.ohaus.com/weee.
Thank you for your contribution to environmental protection.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Frontier
TM
FC5306 EN-9
FCC Note
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Note
This Class B digital apparatus complies with Canadian ICES-001.
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
Ohaus Corporation
7 Campus Drive
Suite 310
Parsippany, NJ 07054 USA
With offices worldwide / Con oficinas en todo el mundo/ Avec des bureaux
dans le monde entier/ Mit Niederlassungen weltweit/ Con uffici in tutto il
mondo
http://www.ohaus.com
*30129575*
P/N 30129575 C © 2017 OHAUS Corporation, all rights reserved / todos los
derechos reservados / tous droits réservés / Alle Rechte vorbehalten / Tutti i
diritti riservati
Printed in China / Impreso en China/ Imprimé en Chine / Gedruckt in China /
Stampato in Cina
(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Ohaus OHA-30134157 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues