SAFETY INFORMATION
!
WARNING
If the information in these instructions
are not followed exactly, a fi re may result
causing property damage, personal injury
or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
$10.00
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No.46 / UL 1278 CSA STANDARD
EF30
ELECTRIC FIREPLACE
NEFB30GL
ELECTRIC FIREPLACE
W415-2166 / B / 10.17.18
2
EN
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
TABLE OF CONTENTS
1.0 INTRODUCTION 3
1.1 DIMENSIONS 4
1.2 LISTING APPROVALS 4
1.3 GENERAL INSTRUCTIONS 5
1.4 LABEL LOCATION 6
2.0 LOCATING APPLIANCE 7
2.1 UNPACKING AND TESTING APPLIANCE 7
2.2 GROUNDING APPLIANCE 8
3.0 INSTALLATION 9
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES 10
3.2 MINIMUM MANTEL CLEARANCES 10
3.3 NEW CONSTRUCTION OR RENOVATION 11
3.4 INSTALLING THE APPLIANCE 11
3.5 THERMOSTAT AND THERMAL SENSOR INSTALLATION 11
3.6 HARD-WIRE INSTALLATION 12
3.7 WIRING DIAGRAM 13
4.0 FRAMING 14
5.0 FINISHING 15
5.1 HEARTH 15
5.2 COLD CLIMATE INSTALLATION 15
5.3 FINISHING CHECKLIST 15
6.0 OPERATING INSTRUCTIONS 16
6.1 OPERATING BY REMOTE CONTROL 17
6.2 CRYSTAL EMBER PLACEMENT 18
6.3 LED / REMOTE RECEIVER / THERMOSTAT REPLACEMENT 19
6.4 FUSE REPLACEMENT 19
7.0 REPLACEMENT PARTS 20
7.1 REPLACEMENT PARTS DIAGRAM 21
8.0 TROUBLESHOOTING 22
9.0 WARRANTY 23
10.0 SERVICE HISTORY 24
11.0 NOTES 25
W415-2166 / B / 10.17.18
3
EN
1.0 INTRODUCTION
!
WARNING
C
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate
appliance according to operating instructions could cause fi re or injury.
Risk of burns. Power to the appliance should be turned off and the appliance allowed to cool before
servicing. To disconnect power to the appliance, turn controls to off, then remove plug from outlet.
Do not install damaged, incomplete or substitute components.
Do not burn wood or other materials in this appliance.
Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove,
install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the
room and away from hot surfaces.
Clothing or other fl ammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and
draperies.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
It is imperative that the control compartments, circulating blower and its passageway in the appliance
and are kept clean. The appliance should be inspected before use and at least annually by a qualifi ed
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and
other fl ammable vapors and liquids.
Under no circumstances should this appliance be modifi ed.
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system which has been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the
glass should be done by a licensed or qualifi ed service person.
Do not strike or slam shut the appliance glass door.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
Servicing should be done only while the appliance is disconnected from the power supply circuit.
Always unplug appliance when not in use.
Do not operate this appliance with a damaged cord or plug after the appliance malfunctions, has been
dropped or damaged in any manner. Return appliance to authorized service facility for examination,
electrical or mechanical adjustment, or repair.
Do not use outdoors.
Never locate appliance where it may fall into a bathtub or other water container.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traffi c area and where it will not be tripped over.
Connect to properly grounded outlets only.
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock or fi re, or damage the appliance.
To prevent a possible fi re, do not block air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may become blocked.
Always plug appliances directly into a wall outlet/receptacle. Never use an extension cord or
relocatable power tap (outlet/power strip).
Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a T.V. or other electronic components.
W415-2166 / B / 10.17.18
4
EN
Rating
Plate &
Serial
Number
Power Cord and Thermostat
32
1
/
4
10
3
/
4
32
Heater vents - DO NOT COVER
10
30”
29
1
/
2
26
1
/
2
!
WARNING
HEATER VENTS AND AIR OPENINGS CAN NOT
BE COVERED IN ANY CIRCUMSTANCES.
1.1 DIMENSIONS
This appliance has been tested in accordance with the CSA Standards for fixed and location-dedicated
electric room appliances in the United States and Canada. If you need assistance during installation, please
contact your local dealer.
Model Number NEFB30GL
Description Electric Appliance
Voltage 120V AC
Watts MAX 1500W
Lamp LED
Appliance Width 30" (762mm)
Appliance Height 32 1/4" (820mm)
Appliance Depth 10 3/4" (273mm)
Net Weight 79 lbs (36kg)
Gross Weight 89 lbs (41kg)
NOTE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code, CSA C22.1
as appropriate.
1.2 LISTING APPROVALS
W415-2166 / B / 10.17.18
5
EN
1.3 GENERAL INSTRUCTIONS
A.
Prior to plugging your appliance into an electrical outlet, verify that the house circuit breakers for the
outlet are on.
B.
The appliance may emit a slight, harmless odour when fi rst used. This odour is normal and it is caused
by the initial heating of internal appliance elements and will not occur again.
C.
If your appliance does not emit heat, consult the operation section of this manual for further
information.
D.
Use with a CSA- or UL-certifi ed surge protector.
E.
Do not route the power cord directly underneath the appliance.
This electric appliance meets the construction and safety standards of H.U.D. for application in manufactured
homes when installed according to these instructions.
!
WARNING
READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY
AND/OR PROPERTY DAMAGE.
ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE
IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE PRESENT.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL
ACCESSORIES LISTED IN THESE INSTRUCTIONS. USE OF OPTIONAL ACCESSORIES NOT
SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND/OR
RESULT IN A SAFETY HAZARD.
DO NOT OPEN. RISK OF ELECTRIC SHOCK. NO USER-SERVICEABLE PARTS INSIDE.
DO NOT USE DAMAGED ELECTRICAL CORDS.
SERVICING SHOULD BE DONE ONLY WHILE THE APPLIANCE IS DISCONNECTED FROM THE
POWER SUPPLY CIRCUIT.
TO PREVENT ELECTRIC SHOCK MATCH THE WIDE BLADE OF PLUG TO WIDE SLOT OF
RECEPTACLE AND FULLY INSERT.
W415-2166 / B / 10.17.18
6
EN
1.4 LABEL LOCATION
W415-2166 / B / 10.17.18
7
EN
2.0 LOCATING APPLIANCE
NOTICE
Minimum clearance of 1" on all sides, back and top must
be maintained at all times. Illustrations throughout these
instructions reflect typical installations and are for design
purposes only. Actual installations may vary slightly due to
individual preferences.
Illustrates a variety of ways the appliance may be located
in a room. The appliance may be installed directly on the
floor (uncarpeted), or raised on a hearth.
TOP VIEW SHOWING APPROVED ROOM
LOCATIONS OF APPLIANCE
Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance
operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet.
2.1 UNPACKING AND TESTING APPLIANCE
!
WARNING
DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS,
CLOTHES AND CURTAINS AT LEAST 3 FEET (0.9M) FROM THE FRONT OF THE APPLIANCE.
NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER
WATER CONTAINER.
WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND
MAINTENANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE ELECTRIC APPLIANCE MUST
NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION. LOCALIZED
OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
W415-2166 / B / 10.17.18
8
EN
2.2 GROUNDING APPLIANCE
GROUNDING METHODS
METAL SCREW
(A)
NOT ALLOWED IN CANADA
GROUNDING
MEANS
ADAPTER
GROUNDING PIN
COVER OF
GROUNDED
OUTLET BOX
(C)
(B)
This appliance is for use on 120 volts. The cord has a plug
as shown in (A). An adapter as shown in (C) is available for
connecting three-blade grounding type plugs to two-slot
receptacles. The green grounding plug extending from the
adapter must be connected to a permanent ground such as
a properly grounded outlet box. The adapter should not be
used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove
plug from outlet.
W415-2166 / B / 10.17.18
9
EN
BEFORE INSTALLATION
Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high
traffic areas. NOTE: Follow all national and local electrical codes. This appliance can be installed into
either an existing fireplace opening or as new construction / renovation.
EXISTING APPLIANCE INSTALLATION
Thoroughly clean out the existing fireplace and hearth area.
Plan the power supply. If an existing grounded outlet is near the appliance, the power cord can run behind
the appliance. If the cord is not long enough to reach the outlet, a grounded extension cord minimum AWG
No. 14 and rated to a minimum of 1875 watts may be used. If you plan to cut or drill a hole in the existing
fireplace for wiring, it is best to hire a professional to do this step in order to prevent personal injury. To reduce
the risk of fire, do not run the power cord under rugs, carpets, etc. Arrange the power supply cord away from
high traffic areas where it may pose a tripping hazard.
3.0 INSTALLATION
!
WARNING
RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE
CORD TO AVOID TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
PERSONAL INJURY. DO NOT RUN CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW
RUGS, RUNNERS OR THE LIKE. ARRANGE CORD AWAY FROM TRAFFIC AREAS AND WHERE IT
WILL NOT BE TRIPPED OVER.
RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY
MANNER. DO NOT USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.
RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED
OPTIONAL ACCESSORIES. USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR
THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND/OR RESULT IN A SAFETY HAZARD.
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
THIS APPLIANCE MUST REMAIN REMOVABLE FROM THE ENCLOSURE. THE APPLIANCE MAY BE
HARD WIRED, BUT IT IS RECOMMENDED THAT IT BE PLUGGED INTO A STANDARD OUTLET USING
THE SUPPLIED POWER CORD. THIS APPLIANCE MUST NOT BE SEALED AROUND THE FRONT
FACING.
APPLIANCE VENTS LOCATED ON THE FRONT AND BACK OF THIS ELECTRIC APPLIANCE CANNOT,
IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE HAZARD.
W415-2166 / B / 10.17.18
10
EN
Sides, back, top 1" (25mm)
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES
THIS APPLIANCE MUST REMAIN REMOVABLE FROM THE ENCLOSURE. THE APPLIANCE MAY BE HARD
WIRED, BUT IT IS RECOMMENDED THAT IT BE PLUGGED INTO A STANDARD OUTLET USING THE
SUPPLIED POWER CORD. THIS APPLIANCE MUST NOT BE SEALED AROUND THE FRONT FACING.
APPLIANCE VENTS LOCATED ON THE FRONT AND BACK OF THIS ELECTRIC APPLIANCE CANNOT,
IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE HAZARD.
!
WARNING
3.2 MINIMUM MANTEL CLEARANCES
The minimum distance from the top of the appliance that the mantel can be installed is 10" (254mm), at any depth.
APPLIANCE
SIDEVIEW
FRONT
GLASS
OPTIONAL
HEARTH
WALL
MANTEL
10”
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
W415-2166 / B / 10.17.18
11
EN
A. Select a location that is not prone to moisture and is located at least 0.9 m or 3 feet away from
combustible materials such as curtains or drapes, furniture, bedding, paper, etc.
B. Place the appliance in selected location to see how it will look in the future.
C. Mark the desired location on the floor and store appliance in a safe, dry and dust free location.
D. Frame in an opening leaving at least 1/4" (6 mm) around the edge of the appliance. Any new wiring
must be done in compliance with local and national codes and other applicable regulations in order
to reduce the risk of fire, electric shock or other injuries. Therefore, it is strongly recommended that
you hire a professional to complete any such work.
A. Once the site has been prepared, the appliance can be installed.
B. Make sure the main power switch is in the "OFF" position.
C. Plug the appliance into a 15-amp/120 Volt, grounded outlet. Use a CSA or UL approved surge
protector.
D. Push in the appliance so that the trim is against the finished mantel or wall surface.
3.3 NEW CONSTRUCTION OR RENOVATION
3.4 INSTALLING THE APPLIANCE
3.5 THERMOSTAT AND THERMAL SENSOR INSTALLATION
This appliance has two options for heat control.
First is a thermal controlled sensor, which comes plugged into the appliance beside the main power cord.
This sensor has no user temperature set points, it will turn off the heater when the sensor reaches its pre-set
point, and will only turn the heater back on when it has cooled back down below this set point. On the low
setting (green light) the set point is 16°C/61°F, on medium (orange light) 22°C/72°F and on high (red light)
28°C/82°F. This small sensor can be placed anywhere in the room within the length of the sensor wire, but it
should not be placed near the top or front of the appliance. Placing the sensor too close to the heater area of
the appliance will cause unwanted cycling of the heater.
Second is the option of a wall-mounted thermostat. Napoleon Part # W690-0001, W660-0081, or an equiva-
lent low voltage thermostat.
A wall thermostat can be used in place of the thermal control sensor. You must first remove the sensor by un-
plugging it from the right side of the appliance beside the main power cord. Replace the sensor with the wire
harness provided in the manual baggie. Plug it into the appliance and connect the other end to the thermo-
stat. The thermostat should be placed as per the thermostat installation instructions.
W680-0022
Thermo-controlled sensor
5M Temperature Probe (included)
W415-2166 / B / 10.17.18
12
EN
HARDWIRING CONNECTION
If it is necessary to hardwire this appliance, a qualified electrician may remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hardwired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the cur-
rent ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
A. Remove cover plate located beside the power cord to reveal the 7/8” wire hole. Discard cover plate,
screws and insert a box connector into the hole.
B. Remove the lower back panel from the appliance to expose wiring.
C. Remove the power cord strain-relief from the side of the appliance and cut the cord where shown
below. This will be the hardwire connection point.
D. Feed the supply wires through the box connector and the grommet.
E. Using wire connectors connect the common (white) wires together, then the hot (black) wires, and
then the ground (green) wires.
F. Ensure the newly connected wires are kept away from the rotating parts and the circuit board, and
re-install the back panel.
NOTE: This appliance must be serviced from the back, leave enough wire so that the appliance can be
removed from the enclosure without disconnecting the power supply wires.
3.6 HARDWIRE INSTALLATION
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
Remove 2 screws on cover plate.
2
3
4
1
Hot Wire
Cut
Power Cord
Final Connection
Common Wire
Ground Wire
Box
Connector
W415-2166 / B / 10.17.18
13
EN
CEILING LIGHT
N
L1
G
3.7 WIRING DIAGRAM
W415-2166 / B / 10.17.18
14
EN
4.0 FRAMING
!
RISK OF FIRE!
IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING
IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE
APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH
ANY OTHER OUTSIDE WALL OF A HOME. THIS WILL ENSURE THAT CLEARANCE TO
COMBUSTIBLES IS MAINTAINED WITHIN THE CAVITY.
DO NOT NOTCH THE FRAMING AROUND THE APPLIANCE STAND-OFFS. FAILURE TO MAINTAIN
AIR SPACE CLEARANCE MAY CAUSE OVER HEATING AND FIRE. PREVENT CONTACT WITH
SAGGING OR LOOSE INSULATION OR FRAMING AND OTHER COMBUSTIBLE MATERIALS. BLOCK
OPENING INTO THE CHASE TO PREVENT ENTRY OF BLOWN-IN INSULATION. MAKE SURE
INSULATION AND OTHER MATERIALS ARE SECURED.
WHEN CONSTRUCTING THE ENCLOSURE ALLOW FOR FINISHING MATERIAL THICKNESS TO
MAINTAIN CLEARANCES. FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS
LISTED MUST BE CONSTRUCTED ENTIRELY OF NON-COMBUSTIBLE MATERIALS. MATERIALS
CONSISTING ENTIRELY OF STEEL, IRON, BRICK, TILE, CONCRETE, SLATE, GLASS OR PLASTERS,
OR ANY COMBINATION THEREOF ARE SUITABLE. MATERIALS THAT ARE REPORTED AS PASSING
ASTM E 136, STANDARD TEST METHOD FOR BEHAVIOUR OF MATERIALS IN A VERTICAL TUBE
FURNACE AT 1382° F (750°C) AND UL763 SHALL BE CONSIDERED NON-COMBUSTIBLE
MATERIALS.
MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD
COULD RESULT.
THE APPLIANCE REQUIRES A MINIMUM ENCLOSURE HEIGHT. MEASURE FROM THE APPLIANCE
BASE.
IF STEEL STUD FRAMING KITS WITH CEMENT BOARD ARE PROVIDED, OR SPECIFIED IN THE
INSTALLATION INSTRUCTIONS, THEY MUST BE INSTALLED.
IF SPECIFIED IN THE INSTALLATION INSTRUCTION FINISHING MUST BE DONE USING A NON-
COMBUSTIBLE MATERIAL SUCH AS NON-COMBUSTIBLE BOARD, CERAMIC TILE, MARBLE, ETC.
DO NOT USE WOOD OR DRYWALL. ANY FIRE RATED DRYWALL IS NOT ACCEPTABLE
H
E
AD
E
R
29"
[737mm]
31 1/2"
[800mm]
11 3/4"
[298mm]
L
K
J
B
C
B
A
NEFB30GL
B
29" (737mm)
J
50" (1270mm)
K
35 3/8" (898mm)
L
35 3/8" (898mm)
W415-2166 / B / 10.17.18
15
EN
A hearth is NOT necessary but is recommended for aesthetic purposes.
IT IS MANDATORY TO HAVE AN INSULATED WALL BEHIND THE APPLIANCE, WHEN THE
APPLIANCE IS BEING INSTALLED ON AN OUTSIDE WALL OR CHASE.
5.0 FINISHING
5.1 HEARTH
5.2 COLD CLIMATE INSTALLATION
!
WARNING
A. Power supply service must be completed prior to finishing to avoid reconstruction.
B. Appliance vents and air openings cannot be covered in any circumstances.
5.3 FINISHING CHECKLIST
RISK OF FIRE!
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.
!
WARNING
W415-2166 / B / 10.17.18
16
EN
6.0 OPERATING INSTRUCTIONS
HIGH LOW TEMP OFF
High
Brightness
Medium
Brightness
Low
Brightness
Light off
After turning the power switch on, the power indicator is red.
First press of the "
" button : the heating element is on "HIGH" mode, two groups of heating elements work
simultaneously while the power is 1500W, indicator is red.
Second press of the button "
": the heating element is on "LOW" mode, one group of heating elements
work while the power is 750W, indicator is blue.
Third press of the button "
": the heating element is on "TEMP" mode. When "TEMP" mode is on, the
appliance automatically sets the room temperature as 25°C. When the room temperature is above 25°C, the
heating element shuts off. When the room temperature is below 22°C, the heating element starts working at
1500W. When the room temperature is between 22-25°C, the heating element starts working at 750W.
Fourth press of the button "
": turns off the heating element.
Press button "
": flame and ember bed work simultaneously in the following sequence:
Press button "
": the ceiling light is switched on. The first press gradually increases the brightness of
blue light. The second to fourth press switches lights in sequence of blue, amber and yellow. The fifth press
switches the light to a combination of blue, yellow and amber light. The sixth press shuts off the lights.
W415-2166 / B / 10.17.18
17
EN
NOTE: Make sure your batteries are
fully charged and installed correctly
in your remote control.
6.1 OPERATING BY REMOTE CONTROL
1. Plug in the power cord and turn on the power switch. You will hear the buzzer make
two beep sounds, indicating that the power is turned on. Press the "
" key to start
up the appliance. Flame and ember bed LEDs will turn on with the brightness level set
to the highest as the default, the heating element will be off and the ceiling light will
turn on the color starting to change gradually from bright blue.
2. The “ ” button is the switch for entire appliance, when the appliance is turned off,
press “
”; the appliance is turned on with the same setting as the last time it has
been turned off. When the appliance is turned on, press “
” button, the appliance
powers off; the ember bed, flame, heating element and background light are turned
off. The other function buttons listed as following can only work under the condition
that the “
” is on. If the flame is off when the appliance is turned off, the brightness
level of the flame and ember bed LED are set to highest when “
” is pressed to turn
on the appliance.
3. Button "
": When the flame and ember bed LEDs are turned on, press the button,
and the light of the flame and ember bed will turn off. When the flame and ember bed
LEDs are off, press the button to turn on the flame and ember bed LEDs.
4. Yellow button “
” controls the six brightness levels of the yellow LED flame lights;
the brightness level changes with each press until you turn the light off completely;
press the button again to repeat the cycle.
5. Blue button “
”, controls the six brightness levels of the blue LED flame lights; the brightness level changes
with each press until you turn the light off completely; press the button again to repeat the cycle.
6. Pink button “
”, controls the six brightness levels of the pink LED flame lights; the brightness level changes
with each press until you turn the light off completely; press the button again to repeat the cycle.
7. Ember button “
”, controls the six brightness levels of ember bed LED lights; the brightness level changes
with each press until you turn the light off completely; press the button again to repeat the cycle.
8. Button “ ”, press this button to turn on the heating element. The heating element starts to work on
“HIGH” mode with the power at 1500W; press the button again to turn off the heating element.
9. Button “
”, press this button and the heating element starts to work on “LOW” mode (750W), press again
and the heating element starts to work on “HIGH” mode (1500W). Press again to repeat the cycle change.
10. Button “
”, press this to start TEMP mode. When "TEMP mode is on, the appliance automatically sets the
room temperature at 25°C. When the room temperature is above 25°C, the heating element shuts off. When
the room temperature is below 22°C, the heating element starts working at 1500W. When the room tempera-
ture is between 22-25°C, the heating element starts working at 750W.
Caution: “HIGH” “LOW” “TEMP” buttons only work under the condition when “
” is in the on position.
When the appliance is on “HIGH” or “LOW” mode, the heating element is turned on all the time and the
thermostat will not work.
11. Button “
” controls the ceiling light. Below shows the work mode of the ceiling light:
Blue Amber Yellow Blinking Switch off
W415-2166 / B / 10.17.18
18
EN
6.2 CRYSTAL EMBER PLACEMENT
1. Unscrew the two screws at the bottom of the front plate.
2. Unhook and lift off the frame of the inner surface and
place carefully on a safe work surface.
3. Unscrew the two screws on the ember tray with a screw-
driver.
4. Remove the logset and put the crystals in.
5. Re-install the frame of the inner surface.
FRONT PLATE
UNSCREW LOGSET
Front View of Appliance
PLACE CRYSTALS
2 Screws
2 Screws
UNHOOK INNER FRAME
PLACE CRYSTALS
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
W415-2166 / B / 10.17.18
19
EN
6.3 LED / REMOTE RECEIVER / THERMOSTAT REPLACEMENT
6.4 FUSE REPLACEMENT
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
1. To replace LED lights in the ember bed, flame and/or decorative lights, disconnect the quick connect plug
from the control board and replace with a new one.
2. To replace the remote receiver and thermostat wires, disconnect the quick connect plug from the control
board and replace with a new one.
T
O
P
L
IG
H
T
F
L
A
M
E
L
E
D
E
M
B
E
R
B
E
D
/ L
O
G
L
E
D
T
H
E
R
M
O
S
T
A
T
R
E
M
O
T
E
R
E
C
E
IV
E
R
C
O
N
T
R
O
L
P
A
N
E
L
F
U
S
E
C
O
V
E
R
1. Remove the plastic cover from the fuse. Pull the fuse (2Amp) out from the control board. Install the re-
placement fuse and plastic cover.
W415-2166 / B / 10.17.18
20
EN
7.0 REPLACEMENT PARTS
Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts
can be ordered through your Authorized dealer / distributor.
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE
REQUIRED TO HONOUR THE CLAIM.
When ordering replacement parts always give the following information:
Model & Serial Number of appliance
Installation date of appliance
Part number
Description of part
Finish
PARTS, PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE.
PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST
DELIVERY DESTINATIONS.
PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO 4 WEEK PERIOD, FOR
MOST CASES.
PARTS IDENTIFIED AS ‘SO’ ARE SPECIAL ORDER AND CAN TAKE UP TO 90 DAYS FOR DELIVERY.
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
!
WARNING
COMPONENTS
REF # PART # DESCRIPTION STOCKED
1
W300-0178 (540G) CRYSTAL YES
2
W300-0246 LARGE DECORATIVE CRYSTAL YES
3
W190-0109 CIRCUIT BOARD YES
4
W010-3966 HEATER AND BLOWER ASSEMBLY YES
5
W660-0128 MAIN POWER SWITCH YES
6
W190-0110 REMOTE CONTROL YES
7
W405-0043 EMBER BED LED YES
8
GBL38-001.02-00 FRONT GLASS PANEL YES
9
GBL38-000-07 MIRROR GLASS YES
10
W010-3965 DRUM ASSEMBLY YES
11
W660-0129 REMOTE RECEIVER YES
12
W080-1719 MEDIA TRAY SO
13
W435-0080 DRUM MOTOR YES
14
W285-0006 FUSE YES
15
W135-0646 LOG SET YES
16
W680-0022 THERMO-CONTROLLED SENSOR YES
ACCESSORIES
REF # PART # DESCRIPTION
17*
W660-0081 DIGITAL THERMOSTAT
18*
W690-0001 MILLIVOLT THERMOSTAT
For after sales service, please call 1-866-820-8686
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

NAPOLEON NEFB30GL Mode d'emploi

Catégorie
Cheminées
Taper
Mode d'emploi

dans d''autres langues