NAPOLEON UVHMS120WB Le manuel du propriétaire

Taper
Le manuel du propriétaire
W415-1309 / B / 11.16.16
EN
FR
PG
15
$10.00
INSTALLER / CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonheatingandcooling.com • [email protected]
- Installation and service must be performed by a
quali ed installer, or a service agency.
- Before servicing, disconnect all electrical power to
furnace.
- When servicing controls, label all wires prior to
disconnecting. Reconnect wires correctly.
- Verify proper operation after servicing.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
SAFETY INFORMATION
ELECTRICAL SHOCK OR FIRE
HAZARD
Failure to follow safety warnings exactly
could result in serious inquiry, death or
property damage.
Improper servicing could result in
dangerous operation, serious injury, death
or property damage.
!
WARNING
!
MANUFACTURER RESERVES THE
RIGHT TO DISCONTINUE, OR CHANGE
AT ANY TIME, SPECIFICATIONS OR
DESIGNS WITHOUT NOTICE AND
WITHOUT INCURRING OBLIGATIONS.
H1.48
UV HAZARD
ALWAYS PROTECT EYES AND EXPOSED
SKIN FROM ULTRAVIOLET LIGHT.
NEVER LOOK AT UV LAMPS IN
OPERATION, SEVERE EYE DAMAGE OR
TEMPORARY BLINDING MAY OCCUR.
UNPLUG OR DISCONNECT POWER
BEFORE RE-LAMPING OR SERVICING.
!
WARNING
!
ULTRAVIOLET LIGHT PURIFICATION SYSTEMS
A
W415-1309 / B / 11.16.16
2
IOM
EN
TABLE OF CONTENTS
1.0 NOMENCLATURE 3
1.1 KIT COMPONENTS 3
2.0 INTRODUCTION 4
2.1 LOW OUTPUT 4
2.2 HIGH OUTPUT 4
3.0 SAFETY SYMBOLS AND WARNINGS 5
4.0 INSTALLATION 6
4.1 BULB ORIENTATION INSTALLATION OPTIONS 7
4.2 MAIN MODULE INSTALLATION 7
4.3 LANCE MODULE INSTALLATION 8
4.3.1 LANCE IS AN ADD ON TO A MODULE 9
4.3.2 LANCE IS AN ADD ON TO A FURNACE 9
5.0 MAINTENANCE 10
6.0 WARRANTY 11
7.0 REPLACEMENT PARTS LIST 12
8.0 SERVICE HISTORY 13
9.0 NOTES 14
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
IMPORTANT:
PLEASE READ THIS MANUAL CAREFULLY
AND KEEP IN A SAFE PLACE FOR FUTURE
REFERENCE BY A SERVICE TECHNICIAN.
W415-1309 / B / 11.16.16
3
EN
1.0 NOMENCLATURE
Ultraviolet
WƵƌŝĮĐĂƟŽŶ
System
• 120W
• 36W
• 18W
UV
H
F
120
FEATURECONFIGURATION
UV BULB
OUTPUT
OUTPUTPRODUCT INCLUDES:
S
WB
• H - High
• L - Low
ͻ&Ͳ&ƵůůDŽĚƵůĞĂŶĚ>ĂŶĐĞ
ͻ>Ͳ>ĂŶĐĞKŶůLJ
ͻDͲDŽĚƵůĞKŶůLJ
ͻͲĚĚKŶ<ŝƚ
^ƚĂŝŶůĞƐƐ^ƚĞĞů
DŽďŝůĞ>ĂŶĐĞ
Head
• WB - With Ballast
ͻtKͲtŝƚŚŽƵƚ
Ballast
1.1 KIT COMPONENTS
UVHFS120WB - High Output 120W Full Kit
• Main Module Head (x1)
• 120W Phillips Smart Ballast (x1)
• Stainless Steel Mobile Lance Head (x1)
• 60W High Output Phillips UV Bulbs (x2)
• Power Supply Cable (x1)
• Jumper Cable (x1)
• Optional Bulb Mount Bracket (x1)
UVHMS120WB - High Output 120W Module
• Main Module Head (x1)
• 120W Phillips Smart Ballast (x1)
• Stainless Steel Mobile Lance Head (x1)
• 60W High Output Phillips UV Bulbs (x2)
• Power Supply Cable (x1)
• Optional Bulb Mount Brackets (x2)
UVLFS036WB - Low Output 36W Full Kit
• Main Module Head (x1)
• 36W Phillips Smart Ballast (x1)
• Stainless Steel Mobile Lance Head (x1)
• 18W UVC Output Phillips UV Bulbs (x2)
• Power Supply Cable (x1)
• Jumper Cable (x1)
• Optional Bulb Mount Bracket (x1)
UVLMS036WB - Low Output 36W Module
• Main Module Head (x1)
• 36W Phillips Smart Ballast (x1)
• Stainless Steel Mobile Lance Head (x1)
• 18W UVC Output Phillips UV Bulbs (x2)
• Power Supply Cable (x1)
• Optional Bulb Mount Bracket (x1)
UVLAS018WB - Low Output 18W Lance Add On
• Main Module Head (x1)
• 36W Phillips Smart Ballast (x1)
• Stainless Steel Mobile Lance Head (x1)
• 18W UVC Output Phillips UV Bulb (x1)
• Ballast Power Supply Cable (x1)
• Ballast to Lance Bulb Harness (x1)
HIGH OUTPUTLOW OUTPUT
W415-1309 / B / 11.16.16
4
IOM
EN
How the HomeShield UV Puri cation System works:
HomeShield UV Modules are designed to operate anytime the furnace has a call for blower circulation – heating,
cooling or continuous fan. Bulbs are coated to prevent OZONE creation. Low output units are for static surface
treatment while high output units will treat air and surfaces.
Multi Head Operation can be utilized to sterilize the air stream with 240 Watts of UV.
The low output unit works primarily to irradiate the evaporator coil of mould spores and bacterial growth. A wet
coil surrounded by warm air provides an ideal environment for mould spores and bacterial growth. A low output
36W UV module with ample coil exposure time will provide enough ultraviolet light energy to effectively render
the microbes ineffective and unable to multiply. This will prevent the evaporator coil from becoming blocked which
will help to maintain the ef ciency of the A/C unit and will increase the service life of the furnace and A/C system.
The high output module at 120W can effectively reduce the microbes ability to reproduce and multiply within a
moving air stream. Exposure time is very important in this system. All household microbes require varying amounts
of UVC exposure to render them ineffective. This means that the slower the air passes by the system the greater
effect it will have. The high output system will also keep your evaporator coil free of bacterial growth which will
help to maintain the ef ciency of the A/C unit and will increase the service life of the furnace and A/C system.
2.0 INTRODUCTION
2.1 LOW OUTPUT
2.2 HIGH OUTPUT
W415-1309 / B / 11.16.16
5
EN
H6.0
IMPORTANT:
READ THE FOLLOWING INSTRUCTIONS COMPLETELY BEFORE INSTALLING!
H3.3.1
Understand and pay particular attention to the words DANGER, WARNING, and CAUTION and the following
de ned symbols are used throughout this manual to notify the reader of potential hazards of varying risk levels.
DANGER
! !
INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL
RESULT IN DEATH OR SERIOUS INJURY.
INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED,
COULD RESULT IN DEATH OR SERIOUS INJURY.
WARNING
!
!
INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, MAY
RESULT IN MINOR OR MODERATE INJURY. IT MAY ALSO BE USED TO ALERT
AGAINST UNSAFE PRACTICES.
CAUTION
!
!
3.0 SAFETY SYMBOLS AND WARNINGS
W415-1309 / B / 11.16.16
6
IOM
EN
H3.86
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE
PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS
UV APPLIANCE. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE,
POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
WARNING
!
!
H3.82
UV HAZARD. ALWAYS PROTECT EYES AND EXPOSED SKIN FROM ULTRAVIOLET LIGHT.
NEVER LOOK AT UV LAMPS IN OPERATION,
SEVERE EYE DAMAGE OR TEMPORARY BLINDING MAY OCCUR.
UNPLUG OR DISCONNECT POWER BEFORE RE-LAMPING OR SERVICING.
WARNING
!
!
H3.83
DO NOT OPERATE OUTSIDE OF AIR HANDLER.
MOUNT LAMP BASE TO DUCT FIRST.
WARNING
!
!
H3.84
NO OPENINGS IN DUCT ARE ALLOWED
WHICH WOULD GIVE DIRECT LINE-OF-SIGHT TO THE UV LIGHT.
WARNING
!
!
H3.85
DO NOT TOUCH LAMP GLASS WITHOUT GLOVES.
REDUCED PERFORMANCE OF LAMP MAY RESULT. CLEAN AFTER HANDLING.
CAUTION
!
!
4.0 INSTALLATION
In the event of accidental breakage or replacement of the ultraviolet lamp, please ensure that the lamp is disposed
of in accordance with local and state environmental laws regarding uorescent lamps containing mercury.
NOTE
All wiring inside of the duct or air handling system in direct line of site of the UV lamp must be shielded
with aluminum foil tape or equivalent non-combustible material. When installing this unit, select a mounting
location that prevents ultraviolet light exposure to plastic exible duct liner or other plastic components with
unknown resistance to ultraviolet light. Ultraviolet light may cause color shift or structural degradation of
plastic HVAC components.
W415-1309 / B / 11.16.16
7
EN
4.1 BULB ORIENTATION INSTALLATION OPTIONS
We have provided several options of bulb orientation for the installer to choose from. This is to accommodate
any duct system and evaporator coil combination. The following pictures depict the options available for both the
high output and low output primary module. If also using the mobile lance module, take into consideration that
there will only be one bulb in the primary module, although all position options are still available.
4.2 MAIN MODULE INSTALLATION
1. Disconnect power to the furnace using the furnace disconnect /
service switch and preferably furnace power circuit from breaker.
2. Locate duct cutout template in desired location for UV Module
keeping in mind location of AC coil, if existing, mark or drill out all
four corners and then cutout 12-1/4” X 6” opening in ductwork.
(Fig.1). Always ensure it is close enough to the HVAC unit to be
able to obtain supply power.
H3.86
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE
PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS
UV APPLIANCE. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING
INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE,
POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
WARNING
!
!
(31.12cm)
12.25”
6.00" (15.24cm)
FIG. 1
W415-1309 / B / 11.16.16
8
IOM
EN
FIG. 2
FIG. 3
3. Mount main module into duct cutout making sure that all edges
and gaps are sealed with supplied weather stripping to prevent any
UV light from escaping plenum. It is not recommended to install
bulbs rst, as offset bulbs will not t through cutout and installing
the unit with bulbs in place could lead to damaged or broken bulbs.
Secure with supplied screws to sheet metal plenum using existing
mount holes. (Fig.2)
4. Mount UV bulbs in desired orientation (1 of 9) making sure the bulbs
are sitting ush in the cutout, and then secure the pre-wired base
and bracket to the enclosure. Modules UV bases are pre-wired
for straight installation. Alternate mount points on the universal
bracket and alternate bulb brackets are included for changing bulb
position and orientation. (Fig.2)
5. Use the enclosed UV shield covers and cover the light bases and
wiring. Ensure that the plastic C-trim on the covers is secure and
that wires are not contacting directly on the metal surface. Verify
all wires are in location before moving on to the next steps. (Fig.3)
6. Place the cover over the tabs on the top of the enclosure and rotate the
cover down slowly into place over the module. This is a tight pressure
t – watch for pinch points. Secure cover in place with provided screw
using a ¼” nut driver. (Fig.4)
7. Connect the power cable to the plug / switch shown at the bottom left of
gure 4. Make sure switch is OFF.
8. The other end contains three leads. Run these three leads through one of
the grommets located on the side of the furnace within the circulating air
blower compartment. Connect power cable end to Integrated Furnace
Control Board. The black lead must be attached to the tap on the control
board that is marked EAC. The white lead must be attached to one of the taps located along the NEUTRAL
portion of the control board. The green lead can be attached anywhere on the control board mounting plate
but it is recommended that it is mounted to the same location as the existing green ground wires.
9. Turn on UV Module power switch, breaker and furnace service disconnect switch.
FIG. 4
4.3 LANCE MODULE INSTALLATION
1. Disconnect the power to the UV unit by turning the switch at the base of the unit to off and disconnect power
to the HVAC unit.
2. Choose where the UV lance will be located; this is typically in the return air stream or in an HRV module.
Always ensure it is close enough to the HVAC unit to be able to obtain supply power.
3. Cut out the template and trace the outline onto the desired location using a black marker.
4. Using a pair of tin snips cut open the location along the template path.
W415-1309 / B / 11.16.16
9
EN
4.3.1 LANCE IS AN ADD ON TO A MODULE
1. Prepare the main module to jump a bulb out to the lance.
2. Connect the included power supply cable between the
primary module and the lance module.
3. Connect the power supply to the HVAC unit and activate the
power switch at the base of the UV unit.
4.3.2 LANCE IS AN ADD ON TO A FURNACE
1. Connect the included power supply cable between the lance and the furnace. The end contains four leads.
Run these four leads through one of the grommets located on the side of the furnace within the circulating
air blower compartment.
2. Mount the UV Ballast to the control board rmly if supplied. Attach Power harness to Ballast – Color coded
for Black, White and Green.
3. Connect the included power supply cable between the ballast and the furnace Integrated Control. The end
contains three leads. The black lead must be attached to the tap on the control board that is marked EAC.
The white lead must be attached to one of the taps located along the NEUTRAL portion of the control board.
The green lead can be attached anywhere on the control board mounting plate but it is recommended that
it is mounted to the same location as the existing green ground wires.
4. Connect lance cable to ballast as shown below for one or two bulb application. Your connection may be
two yellows and two reds if installing a single bulb lance, use the yellow wires in the blue ballast connection.
5. Connect the power supply to the HVAC unit and activate the power switch at the base of the UV unit.
5. Apply the included gasket strips to the outer edges of the back of
the lance module.
6. Mount the lance onto the desired location.
7. Install the UV bulb into the lance module.
8. Mount the lance module cover.
W415-1309 / B / 11.16.16
10
IOM
EN
5.0 MAINTENANCE
H3.85
DO NOT TOUCH LAMP GLASS WITHOUT GLOVES.
REDUCED PERFORMANCE OF LAMP MAY RESULT. CLEAN AFTER HANDLING.
CAUTION
!
!
H3.87
DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE UV APPLIANCE BEFORE
ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK
RESULTING IN PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
!
It is recommended that the bulbs be cleaned on a regular basis, usually every 2-3 months. This will help to main-
tain the desired effectiveness and life span.
Instruction:
1. Be sure to always disconnect power to the unit before performing any type of maintenance.
2. Carefully remove each bulb seperately and wipe them down with a clean and soft cloth. Always be carefull
not to touch the bulb with your bare hands as the oils on your skin can heat up on the bulb and reduce the
life of the bulb.
YEAR JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
3. Record maintenance date on the chart below for future reference.
BULB CLEANING/MAINTENANCE SCHEDULE
INSTALLATION DATE:
MONTH:
YEAR:
W415-1309 / B / 11.16.16
11
EN
6.0 WARRANTY
This UV Puri cation System is warranted by Wolf Steel Ltd. (“HomeShield”)
to be free from defects in materials and workmanship under normal use and
maintenance.
LIMITED WARRANTY (Registered)
To the original registered owner and his or her spouse (“owner”), the
UV module is warranted for 1 year upon installation. The UV bulb is
warranted for 90 days from bill of sale. These warranties apply only if:
The unit is installed in an owner-occupied, primary single family
residence, and
The unit is properly registered with Napoleon online within 60 days
after the original installation. To register, go to
www.napoleonheatingandcooling.com. Some states and provinces
do not allow limitations on how long an implied limited warranty lasts
or do not allow the exclusion or limition of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This limited warranty gives you speci c legal rights, and you may also
have other rights which vary by jurisdiction.
HomeShield may choose to credit its prorated wholesale value towards
the purchase of a new HomeShield UV Puri cation System.
Proof of purchase will be required. Replacements are subject to review and
veri cation by a Napoleon representative.
Warranty ceases to exist if the unit is removed from the location where it was
originally installed.
This limited warranty will not apply unless the UV system is: (1) installed by
a licensed or quali ed HVAC technician, (2) installed in accordance with the
manufacturer’s recommendations in its Installation and Operation Manual,
and (3) in compliance with all industry standards, national, provincial/state,
and local codes.
Regardless of time of registration, the warranty period begins on the date of
the original installation. Where a product is installed in a newly constructed
home; the date of installation is the date the homeowner takes possession of
the home from the builder. If that date cannot be veri ed, the warranty period
begins three months after the month of manufacture (indicated by the rst four
digits of the serial number.
As its only responsibility, and your only remedy, HomeShield will furnish a
replacement part, without charge for the part only, to replace any part that is
found to be defective due to workmanship or materials under normal use and
maintenance.
To make a warranty claim, the defective part must be returned to a
HomeShield heating and air conditioning products dealer/distributor by a
certi ed or licensed contractor. Any part replaced pursuant to this warranty is
warranted only for the unexpired portion of the warranty term applying to the
original part.
These warranties do not apply to labour, freight, or any other cost
associated with the service, repair or operation of the unit, and
diagnostic costs.
HomeShield is not responsible for:
1. Cost or expenses incurred as a consequence of a faulty
installation or application.
2. Damage or repairs required as a consequence of faulty
installation or application.
3. Damages, defects or failures caused by installation that is not
performed in compliance with all applicable federal, provincial,
state laws or regulations, and Installation Operating Manual.
4. Damage as a result of vandalism, freight damage, oods,
res, winds, lightning, and accidents, or any acts of nature.
Atmospheres contaminated by compounds of chlorine,
halogenated hydrocarbons, or other damaging chemicals causing
deterioration of components, or other conditions beyond the
control of Napoleon.
5. Use of components or accessories not compatible with this unit.
6. Products installed outside Canada, or the United States and its
territories.
7. Routine maintenance, but not limited to, cleaning of the coils, lter
cleaning and/or replacement.
8. Parts not supplied by HomeShield.
9. Damage or repairs required as a result of
any improper use,
maintenance, operation,servicing, cleaning or replacing air lters.
10. Failure to operate due to interruption and/or inadequate electrical
service.
11. Damages, defects or failures caused by accidents or negligent or
unreasonable use or operation of the unit and its’ components,
including without limitation, operation beyond rated capacity and
operation of electrical components at voltage other than that
speci ed on the rating plate.
12. HomeShield shall not in any event extend warranty coverage to
any incidental, consequential or indirect damages.
13. Changes in the appearance of the unit that do not affect its
performance.
14. Damages, defects or failures caused by operation of the unit in
abnormal environmental conditions (i.e. salt air).
15. Damages, defects or failures caused by conditioned air (return
air) supplied to the furnace being greater than 20% from out-of-
doors (13°C/55°F min. return air temperature).
16. Damages, defects or failures caused by the UV module being
installed downstream from a cooling coil.
L
IMITED WARRANTY
(
Registered
)
To the ori
g
inal re
g
istered owner and his or her spouse
(“
owner”
)
, the
U
V modul
e
is warranted
f
or 1
y
ear upon installation. The
U
V bul
b
i
s
warranted
f
or 90 da
y
s
f
rom bill o
f
sale. These warranties appl
y
onl
y
i
f:
The unit is installed in an owner-occupied, primar
y
sin
g
le
f
amil
y
esidence, an
The unit is properl
y
re
g
istered with Napoleon online within 60 da
y
s
a
f
ter the ori
g
inal installation. To re
g
ister,
g
o to
www.napoleonheatingandcooling.com
pgg
.
S
ome states and provinces
do not allow limitations on how lon
g
an implied limited warrant
y
lasts
or do not allow the exclusion or limition o
f
incidental or consequential
dama
g
es, so the above limitation or exclusion ma
y
not appl
y
to
y
ou.
This limited warrant
y
g
ives
y
ou speci
c le
g
al ri
g
hts, and
y
ou ma
y
also
h
ave other ri
g
hts which var
y
b
y
j
urisdiction
.
H
ome
S
hield ma
y
choose to credit its prorated wholesale value towards
the purchase o
f
a new Home
S
hield UV Puri
cation
Sy
stem
.
HOMESHIELD UV SYSTEM LIMITED LIFETIME WARRANTY
HomeShield products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete appliance is
again thoroughly inspected by a quali ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from HomeShield.
For further information about this warranty, contact
our
Customer Solutions Department at 866-820-8686,
email [email protected], or by mail to , 24 Napoleon Road, Barrie, Ontario L4M 0G8 Canada
www.napoleonheatingandcooling.com
11.03.16/e
H2.10
Dealer Name
Dealer’s City/Province-State/Postal-Zip Code
Telephone/Fax
E-mail Address
Model and Serial Number
Installation Date
FOR HOMEOWNERS FUTURE REFERENCE
W415-1309 / B / 11.16.16
12
IOM
EN
7.0 REPLACEMENT PARTS LIST
Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally
all parts can be ordered through your Authorized dealer / distributor.
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE
ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
When ordering replacement parts always give the following information:
Model & Serial Number of appliance
Installation date of appliance
• Part number
Description of part
• Finish
FOR FURTHER INFORMATION, CONTACT YOUR AUTHORIZED DEALER.
H41.1
FAILURE TO POSITION THE PARTS
IN ACCORDANCE WITH THIS
MANUAL OR FAILURE TO USE ONLY
PARTS SPECIFICALLY APPROVED
WITH THIS APPLIANCE MAY
RESULT IN PROPERTY DAMAGE OR
PERSONAL INJURY.
!
WARNING
PART NUMBER DESCRIPTION
W010-2810 UV REPLACEMENT BULB 18W KIT
W405-0004 UV SMART BALLAST 36W LOW OUTPUT
W405-0010 UV BULB 60W HIGH OUTPUT
W405-0011 UV SMART BALLAST 120W HIGH OUTPUT
H3.89
Use only Philips UV Bulbs and Smart Ballast.
Failure to use the OEM ballast and bulbs voids warranty and all manufacturer liability.
CAUTION
!
!
W415-1309 / B / 11.16.16
13
EN
8.0 SERVICE HISTORY
43.1
W415-1309 / B / 11.16.16
14
IOM
EN
9.0 NOTES
44.1
W415-1309 / B / 11.16.16
FR
15
$10.00
INSTALLATEUR ET UTILISATEUR : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.
INSTRUCTIONS D’INSTALLATION
ET D’OPÉRATION
LE FABRICANT SE RÉSERVE LE DROIT
DE DISCONTINUER OU DE MODIFIER LES
SPÉCIFICATIONS OU LES CONCEPTIONS
EN TOUT TEMPS SANS PRÉAVIS ET SANS
AUTRE OBLIGATION DE SA PART.
H1.48
CONSIGNES DE SÉCURITÉ
RISQUE DE DÉCHARGE
ÉLECTRIQUE OU D’INCENDIE
Si les consignes de sécurité ne sont pas suivies
à la lettre, cela peut causer des blessures graves,
des pertes de vie ou des dommages matériels.
Un entretien inadéquat pourrait occasionner un
fonctionnement dangereux, des blessures graves,
des pertes de vie ou des dommages matériels.
!
AVERTISSEMENT
!
RISQUE ASSOCIÉ À LA LUMIÈRE UV
PROTÉGEZ TOUJOURS VOS YEUX ET LA PEAU
EXPOSÉE DE LA LUMIÈRE UV. NE REGARDEZ
JAMAIS UNE LAMPE UV LORSQUE CELLE-CI
EST ALLUMÉE; DES BLESSURES GRAVES AUX
YEUX OU UN AVEUGLEMENT TEMPORAIRE
POURRAIENT SURVENIR. DÉBRANCHEZ LA
SOURCE D’ALIMENTATION ÉLECTRIQUE AVANT
DE REMPLACER LA LAMPE OU DE FAIRE
L’ENTRETIEN DE L’APPAREIL.
!
AVERTISSEMENT
!
- L’installation et l’entretien doivent être faits par un
installateur quali é, ou une agence d’entretien.
- Avant d’effectuer l’entretien, débranchez l’alimentation
électrique de l’appareil.
- Lors de l’entretien des contrôles, étiquetez tous les ls
avant de les débrancher. Rebranchez-les correctement.
- Véri ez le bon fonctionnement après l’entretien.
- N’entreposez pas et n’utilisez pas d’essence ou autres
liquides et vapeurs in ammables à proximité de cet
appareil ou de tout autre appareil.
Wolf Steel ltée, 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, É.-U., 41030
Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonheatingandcooling.com • [email protected]
SYSTÈMES DE PURIFICATION D’AIR UV
W415-1309 / B / 11.16.16
FR
16
TABLE OF CONTENTS
1.0 DESCRIPTION DU MODÈLE 17
1.1 PIÈCES D’ÉQUIPEMENT 17
2.0 INTRODUCTION 18
2.1 BASSE PUISSANCE 18
2.2 ÉLEVÉE PUISSANCE 18
3.0 SYMBOLES DE SÉCURITÉ ET AVERTISSEMENTS 18
4.0 INSTALLATION 19
4.1 OPTIONS D’INSTALLATION POUR L’ORIENTATION DE L’AMPOULE 20
4.2 INSTALLATION DU MODULE PRINCIPAL 20
4.3 INSTALLATION DU MODULE DE LA LAMPE 21
4.3.1 LA LAMPE EST UN AJOUT À UN MODULE 22
4.3.2 LA LAMPE EST UN AJOUT À LA FOURNAISE 22
5.0 ENTRETIEN 23
6.0 GARANTIE 24
7.0 SLISTE DES PIÈCES DE RECHANGE DE LA FOURNAISE À UNE ÉTAPE 25
8.0 HISTORIQUE D’ENTRETIEN 26
9.0 NOTES 27
IMPORTANT :
VEUILLEZ LIRE CE MANUEL ATTENTIVEMENT
ET LE GARDER DANS UN ENDROIT
SÉCURITAIRE POUR QU'UN TECHNICIEN
DE SERVICE PUISSE LE CONSULTER
ULTÉRIEUREMENT.
NOTE : Les changements, autres que de nature éditoriale, sont dénotés par une ligne verticale dans la
marge.
W415-1309 / B / 11.16.16
FR
17
1.0 DESCRIPTION DU MODÈLE
Systèmes De
WƵƌŝĮĐĂƟŽŶ
D’air Uv
• 120W
• 36W
• 18W
UV
H
F
120
CARACTÉRISTIQUES
CONFIGURATION
PUISSANCE DE
L’AMPOULE UV
PUISSANCEPRODUIT COMPREND :
S
WB
• H - Élevée
• L - Basse
• F - Module Complet Et Lampe
ͻ>ͲDŽĚƵůĞĞ>Ă>ĂŵƉĞ^ĞƵůĞŵĞŶƚ
ͻDͲDŽĚƵůĞ^ĞƵůĞŵĞŶƚ
ͻͲŶƐĞŵďůĞ͛ĂƉƉŽŝŶƚ
te De Lampe
DŽďŝůĞŶĐŝĞƌ
/ŶŽdžLJĚĂďůĞ
ͻtͲǀĞĐĂůůĂƐƚ
ͻtKͲ^ĂŶƐĂůůĂƐƚ
1.1 PIÈCES D’ÉQUIPEMENT
UVHFS120WB - Ensemble Complet À
Puissance Élevée (120 W)
• Tête Du Module Principal (x1)
• Ballast Intelligent Philips De 120 W (x1)
• Stainless Steel Mobile Lance Head (x1)
• 60W High Output Phillips UV Bulbs (x2)
• Câble D’alimentation Électrique (x1)
• Câble De Raccordement (x1)
• Support De Fixation Optionnel Pour
L’ampoule (x1)
UVHMS120WB - Module À Puissance Élevée
(120 W)
• Tête Du Module Principal (x1)
• Ballast Intelligent Philips De 120 W (x1)
• Stainless Steel Mobile Lance Head (x1)
• 60W High Output Phillips UV Bulbs (x2)
• Câble D’alimentation Électrique (x1)
• Support De Fixation Optionnel Pour
L’ampoule (x2)
UVLFS036WB – Ensemble Complet À Basse
Puissance (36 W)
• Tête Du Module Principal (x1)
• Ballast Intelligent Philips De 36 W (x1)
• Stainless Steel Mobile Lance Head (x1)
Ampoules Uv Philips D’une Puissance
De 18 W (x2)
• Câble D’alimentation Électrique (x1)
• Câble De Raccordement (x1)
• Support De Fixation Optionnel Pour
L’ampoule (x1)
UVLMS036WB - Module À Basse Puissance (36 W)
• Tête Du Module Principal (x1)
• Ballast Intelligent Philips De 36 W (x1)
• Stainless Steel Mobile Lance Head (x1)
Ampoules Uv Philips D’une Puissance
De 18 W (x2)
• Câble D’alimentation Électrique (x1)
• Support De Fixation Optionnel Pour
L’ampoule (x1)
UVLAS018WB - Lampe D’appoint À Basse
Puissance (18 W)
• Tête Du Module Principal (x1)
• Ballast Intelligent Philips De 36 W (x1)
• Stainless Steel Mobile Lance Head (x1)
Ampoules Uv Philips D’une Puissance
De 18 W (x1)
• Câble D’alimentation Électrique Du Ballast (x1)
• Harnais Du Ballast Jusqu’à L’ampoule De La
Lampe (x1)
BASSE PUISSANCE
ÉLEVÉE PUISSANCE
W415-1309 / B / 11.16.16
FR
18
Fonctionnement du système de puri cation d’air UV HomeShield :
Les modules UV HomeShield sont conçus pour fonctionner chaque fois que la fournaise reçoit une demande pour
mettre en marche la souf erie, que ce soit pour le chauffage, le refroidissement ou la ventilation continue. Les
ampoules sont recouvertes pour prévenir la formation d’OZONE. Les appareils à basse puissance sont conçus
pour le traitement des surfaces statiques tandis que les appareils à puissance élevée le sont pour le traitement
de l’air et des surfaces.
Avec 240 watts de lumière UV, le fonctionnement à plusieurs têtes peut être utilisé pour stériliser le courant d’air.
L’appareil à basse puissance est principalement conçu pour irradier le serpentin de l’évaporateur et éliminer
les spores de moisissures et la croissance bactérienne. Un serpentin humide entouré d’air chaud constitue
un milieu idéal pour les spores de moisissures et la croissance bactérienne. Un module UV à basse puis-
sance (36 W) et une durée d’exposition suf sante du serpentin fourniront assez d’énergie UV pour détruire les
microbes et les empêcher de se multiplier. Cela préviendra le blocage du serpentin de l’évaporateur, ce qui,
en retour, préservera l’ef cacité du climatiseur et augmentera la durée de vie de la fournaise et du système de
climatisation.
Le module à puissance élevée (120 W) peut réduire ef cacement la capacité des microbes à se reproduire et à
se multiplier dans un courant d’air. La durée d’exposition est très importante pour ce système. A n de devenir
inoffensifs, tous les microbes que l’on trouve dans les maisons nécessitent une exposition différente à la
lumière UV. Cela signi e que plus l’air circule lentement dans le système, plus l’effet est important. Le système
à puissance élevée empêchera également la croissance bactérienne dans le serpentin de l’évaporateur,
ce qui, en retour, préservera l’ef cacité du climatiseur et augmentera la durée de vie de la fournaise et du
système de climatisation.
2.0 INTRODUCTION
2.1 BASSE PUISSANCE
2.2 ÉLEVÉE PUISSANCE
H6.0
IMPORTANT :
AVANT DE PROCÉDER À L'INSTALLATION, LISEZ TOUTES LES DIRECTIVES SUIVANTES!
H3.3.1
Assurez-vous de comprendre et de porter une attention particulière aux mots DANGER, AVERTISSEMENT
et ATTENTION, ainsi qu'aux symboles dé nis suivants. Ils sont utilisés tout au long de ce manuel pour aviser
le lecteur de dangers potentiels de niveaux de risques variés.
DANGER
! !
INDIQUE UNE SITUATION DANGEREUSE IMMINENTE QUI, SI ELLE N'EST PAS ÉVITÉE,
CAUSERA LA MORT OU DES BLESSURES GRAVES.
INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N'EST PAS
ÉVITÉE, POURRAIT CAUSER LA MORT OU DES BLESSURES GRAVES.
AVERTISSEMENT
!
!
INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N'EST PAS
ÉVITÉE, POURRAIT CAUSER DES BLESSURES MINEURES OU MODÉRÉES. PEUT
AUSSI ÊTRE UTILISÉ POUR METTRE EN GARDE CONTRE DES PRATIQUES
NON SÉCURITAIRES.
ATTENTION
!
!
3.0 SYMBOLES DE SÉCURITÉ ET AVERTISSEMENTS
W415-1309 / B / 11.16.16
FR
19
H3.86
CES DIRECTIVES VISENT À AIDER LES TECHNICIENS DE SERVICE QUALIFIÉS À
INSTALLER, À RÉGLER ET À FAIRE FONCTIONNER ADÉQUATEMENT CET APPAREIL
UV. LISEZ CES DIRECTIVES ATTENTIVEMENT AVANT DE PROCÉDER À L’INSTALLATION
DE L’APPAREIL ET DE LE FAIRE FONCTIONNER. SI CES DIRECTIVES NE SONT
PAS RESPECTÉES, L’INSTALLATION, LE RÉGLAGE, LE SERVICE OU L’ENTRETIEN
POURRAIENT ÊTRE INADÉQUATS, CE QUI RISQUERAIT DE CAUSER UN INCENDIE, UNE
DÉCHARGE ÉLECTRIQUE, DES DOMMAGES MATÉRIELS, DES BLESSURES OU LA MORT.
AVERTISSEMENT
!
!
H3.82
RISQUE ASSOCIÉ À LA LUMIÈRE UV. PROTÉGEZ TOUJOURS VOS YEUX ET LA PEAU
EXPOSÉE DE LA LUMIÈRE UV.
NE REGARDEZ JAMAIS UNE LAMPE UV LORSQUE CELLE-CI EST ALLUMÉE; DES
BLESSURES GRAVES AUX YEUX OU UN AVEUGLEMENT TEMPORAIRE POURRAIENT
SURVENIR.
DÉBRANCHEZ LA SOURCE D’ALIMENTATION ÉLECTRIQUE AVANT DE REMPLACER LA
LAMPE OU DE FAIRE L’ENTRETIEN DE L’APPAREIL.
AVERTISSEMENT
!
!
H3.83
NE PAS FAIRE FONCTIONNER À L’EXTÉRIEUR DE L’APPAREIL DE TRAITEMENT D’AIR.
INSTALLER D’ABORD LA BASE DE LA LAMPE SUR LE CONDUIT.
AVERTISSEMENT
!
!
H3.84
NE PAS FAIRE D’OUVERTURES DANS LE CONDUIT; CELA EXPOSERAIT DIRECTEMENT
LA LUMIÈRE UV À LA VUE.
AVERTISSEMENT
!
!
!
H3.85
NE PAS TOUCHER AU VERRE DE LA LAMPE SANS GANTS; LE RENDEMENT DE LA
LAMPE POURRAIT EN ÊTRE RÉDUIT. NETTOYER APRÈS MANIPULATION.
ATTENTION
!
4.0 INSTALLATION
En cas de bris accidentel ou lors du remplacement de la lampe UV, veillez à ce que la lampe soit éliminée
conformément aux lois environnementales locales et nationales se rapportant aux lampes uorescentes contenant
du mercure.
REMARQUE :
Tout le câblage qui se trouve à l’intérieur du conduit ou de l’appareil de traitement d’air et qui est
directement exposé à la lampe UV doit être protégé avec du ruban métallique en aluminium ou un matériau
incombustible équivalent. Lors de l’installation de cet appareil, choisissez un emplacement de montage
a n d’éviter que la doublure de conduit exible en plastique soit exposée à la lumière UV ou que d’autres
composants en plastique, dont la résistance à la lumière UV est inconnue, le soient. La lumière UV peut
provoquer un changement de couleur ou une dégradation structurelle des composants HVAC en plastique.
W415-1309 / B / 11.16.16
FR
20
4.1 OPTIONS D’INSTALLATION POUR L’ORIENTATION DE L’AMPOULE
L’installateur peut choisir parmi nos différentes options pour l’orientation de l’ampoule et, ainsi, s’adapter à toute
combinaison de système de conduits et de serpentin d’évaporateur. Les images suivantes illustrent les options
pouvant convenir autant au module principal à puissance élevée qu’à puissance faible. Si vous avez également
recours au module de la lampe mobile, tenez compte du fait qu’il n’y aura qu’une ampoule dans le module
principal, bien que toutes les options puissent être utilisées.
4.2 INSTALLATION DU MODULE PRINCIPAL
1. Coupez la source d’alimentation électrique de la fournaise au
moyen de l’interrupteur de service et éteignez préférablement le
circuit d’alimentation de la fournaise à partir du disjoncteur.
2. Placez un gabarit de découpe de conduit à l’emplacement désiré
pour le module UV, tout en gardant à l’esprit l’emplacement du
serpentin du climatiseur, s’il y en a un. Marquez ou percez les quatre
coins, et faites une ouverture de 12 1/4 po sur 6 po dans le conduit.
( g. 1) Assurez-vous que le module est toujours suf samment
proche de l’appareil HVAC a n qu’il soit alimenté en courant.
H3.86
CES DIRECTIVES VISENT À AIDER LES TECHNICIENS DE SERVICE QUALIFIÉS À
INSTALLER, À RÉGLER ET À FAIRE FONCTIONNER ADÉQUATEMENT CET APPAREIL
UV. LISEZ CES DIRECTIVES ATTENTIVEMENT AVANT DE PROCÉDER À L’INSTALLATION
DE L’APPAREIL ET DE LE FAIRE FONCTIONNER. SI CES DIRECTIVES NE SONT
PAS RESPECTÉES, L’INSTALLATION, LE RÉGLAGE, LE SERVICE OU L’ENTRETIEN
POURRAIENT ÊTRE INADÉQUATS, CE QUI RISQUERAIT DE CAUSER UN INCENDIE, UNE
DÉCHARGE ÉLECTRIQUE, DES DOMMAGES MATÉRIELS, DES BLESSURES OU LA MORT.
AVERTISSEMENT
!
!
(31.12cm)
12.25”
6.00" (15.24cm)
FIG. 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

NAPOLEON UVHMS120WB Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues