IS-C4_A-C4_NLC_en 11/16 page 1 of 2
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Step 2
Locate luminaire along joist and line up bottom
edge of hinged mounting bar with the bottom
of the joist and fasten in place as shown in Fig.A.
For joist spacing less than 16” on center (down
to 12” on center) mounting bar channels can
be shortened and used as nailing legs in tight
spaces. Simply remove the inner bar from holed
channel, bend channel at appropriate point and
use extra screw to secure it to the joist.
Step 3
Wire in per instructions on next page.
Step 4
Swing up mounting bar to reach opposite joist
and fasten in place. Adjust luminaire to desired
position along mounting bars and lock in place
using locking screw.
Step 1
The patented mounting system allows the
installer to wire in the frame below the ceiling
line. Take notice of the locking screw, which
secures the mounting bar location in the
mounting bar channel.
Instructions for wood frame ceiling applications
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electrical shock, turn o electricity at fuse box before proceeding. Allow xture to cool before handling.
Retain these instructions for maintenance reference
May require minimum center-to-center spacing installation. Must reference light module instruction sheet IS-MS_IC.
Installation for
Calculite Rough-in section
for IC/Airseal and Chicago
Plenum new construction.
IC/Airseal: C4RA, C4SA,
C6RA, C6SA & C7RA
Chicago Plenum: C4RNLC,
C4SNLC, C6RNLC, C6SNLC
& C7RNLC
Caution (RISK OF FIRE)
Use only with LED light modules and
reector trims provided by Philips Lightolier.
Use of other manufacturers trims may void
the Underwriters Laboratories listing and
could constitute a re hazard.
Read and understand these instructions
before installing luminaire (xture).
4
7
8
in
123 mm
13 in
329 mm
Mounting
bar
10
3
8
in
264 mm
Grounding
spring
Mounting
bar clamp
T-bar
clip
16
3
8
in
416 mm
13
1
4
in
337 mm
8
3
4
in
221 mm
10
7
8
in
277 mm
7
1
2
in
190 mm
13 in
329 mm
10
3
8
in
264 mm
16
3
8
in
416 mm
11
1
4
in
286 mm
6
1
8
in
156 mm
13
1
4
in
337 mm
7
3
4
in
197 mm
ø5
3
4
in
146 mm
ø6
1
4
in
158 mm
ø4
1
2
in
114 mm
Ceiling Cutout
ø4
7
8
in
124 mm
ø4
3
8
in
111 mm
4
7
8
in
123 mm
2 in
51 mm
Maximum
ceiling
thickness
3
8
in
10 mm
Driver
receptical
plug
6
1
8
in
156 mm
Note: To insure proper installation, it is important the mounting frame always be secured to structural ceiling members.
Fig.A
Locking screw
Hinged mounting bar
Line up with
bottom of joist
Downlighting
Calculite LED gen 3
IC/Airseal & Chicago Plenum
IS-C4_A-C4_NLC
IS-C4_A-C4_NLC_en 11/16 page 2 of 2
IS-C4_A-C4_NLC Calculite LED generation 3
IC/Airseal & Chicago Plenum
Instructions for grid ceiling applications
© 2016 Philips Lighting Holding B.V. All rights reserved.
Philips reserves the right to make changes in specications
and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences
resulting from the use of this publication.
philips.com/luminaires
Philips Lighting, North America Corporation
200 Franklin Square Drive, Somerset, NJ 08873
Tel. 855-486-2216
Philips Lighting Canada Ltd.
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Tel. 800-668-9008
Wire in: Wire to supply leads. White wire to
neutral supply lead, black wire to hot supply
lead, and bare copper and/or green wire must
be connected to supply ground. Use wire
nuts (local hardware item). Place all electrical
connections in the j-box and close the j-box
door. For luminaires with 0-10V dimming, or
digital dimming, wire purple & gray leads to
appropriate control wires. Additional brown,
yellow and red wires are for emergency
battery pack installations and should remain
capped o when not in use. Additional orange
wire is for future expansion and should also
remain capped o.
For square frames: Adjustment of the position
can be accomplished by loosening the wing
nut clamp and rotating the inner square of the
frame. Re-tighten the wing nut clamp when
appropriately positioned.
Instructions for Airseal applications of IC/Airseal frame-in kits
Instructions for all applications
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Tab
T-Bar
Fig.C
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
View as seen from inside j-box1/2" Metal conduit connector(s)
with locknut
Conduit
connector
Front
Back
Fig.D
Supply
connection
plate
Full diameter
back opening
Break-thru
bushing
(or electrical
tape if full
diameter
connector is
not used)
Supply
leads
Fig.E
Step 1
Rotate hinged bar ends to position shown
(Fig.C) and fully extend bars. Crimp bottom
edge of channel to prevent rotation of hinged
bar ends (Fig.B).
Step 2
Position notched area of mounting bars onto
T-bar and lock by bending tab underneath
T-bar bead as shown (Fig.C).
Step 1
Frames come with a preinstalled gasket that
seals any gap between the bottom of the
frame and the ceiling material. If the top of the
ceiling material is not at, use silicone caulking
to seal any gaps. Two break-thru bushings are
also included to seal supply lead connections.
Step 2
Feed supply leads into a 1/2" connector. Any
1/2" metal conduit connector with full diameter
back opening and locknut can be used (Fig.D).
Secure connector to supply connection plate.
Step 3
Adjust luminaire to desired position along
mounting bar and lock in place using locking
screw.
Step 4
Wire in per instructions below.
Step 3
Pierce bushing by pushing wires into center
or pre-pierce by using a nail that is smaller
than the wire diameter. Slide bushing
up supply leads until fully inserted into
connector (Fig.E).
Step 4
Tighten connector screw(s) to properly secure
supply lead conduit. If a conduit connector
without a full diameter back opening is used,
electrical tape can be wrapped around
supply leads to connector seal openings.
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Crimp here
Mounting
bar channel
Fig.B
IS-C4_A-C4_NLC_fr 11/16 page 1 de 2
Directives pour les applications de plafond à structure de bois
Un espacement centre à centre minimum peut être requis dans l’installation. Vous devez faire référence à la che de directives du module de lumière IS-MS_IC.
Installation pour
Cadres de montage
Calculite pour plafond
isolé/étanche à l’air
et Chicago dans une
nouvelle construction.
Isolé/étanche à l’air: C4RA,
C4SA, C6RA, C6SA & C7RA
Chicago Plenum: C4RNLC,
C4SNLC, C6RNLC, C6SNLC
& C7RNLC
Avertissement (RISQUES D’INCENDIE)
N’utiliser qu’avec des modules DEL et des garnitures
de réecteur de Philips Lightolier. L’utilisation
de garnitures provenant d’autres fabricants peut
annuler l’homologation UL et pourrait causer
un incendie.
4
7
8
in
123 mm
13 in
329 mm
Mounting
bar
10
3
8
in
264 mm
Grounding
spring
Mounting
bar clamp
T-bar
clip
16
3
8
in
416 mm
13
1
4
in
337 mm
8
3
4
in
221 mm
10
7
8
in
277 mm
7
1
2
in
190 mm
13 in
329 mm
10
3
8
in
264 mm
16
3
8
in
416 mm
11
1
4
in
286 mm
6
1
8
in
156 mm
13
1
4
in
337 mm
7
3
4
in
197 mm
ø5
3
4
in
146 mm
ø6
1
4
in
158 mm
ø4
1
2
in
114 mm
Ceiling Cutout
ø4
7
8
in
124 mm
ø4
3
8
in
111 mm
4
7
8
in
123 mm
2 in
51 mm
Maximum
ceiling
thickness
3
8
in
10 mm
Driver
receptical
plug
6
1
8
in
156 mm
Note: An d’assurer une installation adéquate il est important de rattacher le cadre de montage sur la structure du plafond.
Ce luminaire a été conçu pour une installation respectant les exigences du Code électrique national et des
réglementations locales. An de garantir la conformité avec les codes et réglementations locaux, consulter
un inspecteur électrique local avant deectuer l’installation. An de prévenir les chocs électriques, couper
l’alimentation à la bte de disjoncteurs avant de débuter. Laisser refroidir le luminaire avant de le manipuler.
Garder ces directives pour références futures
Avant de débuter l’installation du luminaire,
veuillez lire et bien comprendre ces directives.
Étape 2
Positionner le luminaire le long de la solive et
aligner avec la bordure inférieure de la barre de
montage à charnre avec la partie inférieure
de la solive tel qu’illustré dans la Fig. A. Pour
l’espacement des solives de moins de 16 po au
centre (jusqu’à 12 po au centre) les prolés de
la barre de montage peuvent être raccourcis
et utilisés comme patte de clouage dans les
espaces restreints. Il sut de retirer la barre
interne du prolé creux, de plier le prolé à
la location adéquate et d’utiliser une vis pour
rattacher à la solive.
Étape 3
Eectuer les connexions en suivant les
directives sur la prochaine page.
Étape 4
Soulever la barre de montage pour atteindre la
solive oppoe et rattacher en place. Ajuster le
luminaire à la position recherce et verrouiller
en place à l’aide des vis de blocage.
Étape 1
Le système de montage breveté permet à
l’installateur de rattacher le cadre à l’aide d’un
l en dessous du plafond. Repérer la location
de la vis de blocage qui rattache la barre de
montage dans le prolé de la barre de montage.
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Fig.A
Vis de blocage
Barre de montage à charnière
Avec le fond
de la solive
Éclairage direct
Calculite DEL gén. 3
isolé/étanche à lair
et Chicago Plenum
IS-C4_A-C4_NLC
IS-C4_A-C4_NLC_fr 11/16 page 2 de 2
IS-C4_A-C4_NLC Calculite DEL génération 3
isolé/étanche à lair et Chicago Plenum
Directives pour les applications à plafond à grille
Brancher l’alimentation : Connecter
l’alimentation. Raccorder le l d’alimentation
neutre blanc et le l de cuivre dénudé et/
ou le l vert au l de mise à la terre de
l’alimentation. Utiliser des écrous à oreilles
(de votre quincaillerie locale). Placer toutes
les connexions électriques dans la bte de
jonction et refermer la porte de la bte de
jonction. Pour les luminaires à gradation
0-10V ou à gradation numérique, raccorder
les ls pourpre et gris aux ls de contrôle
correspondants. Les ls brun, jaune et rouge
additionnels sont pour les installations de
bloc de batterie de secours et devraient être
recouverts d’une marette lorsque les ls ne
sont pas utilils. Le l orange additionnel
sert à une future expansion et devrait être
recouvert d’une marette.
Pour les cadres cars : L’ajustement de la
position s’eectue en desserrant la pince de
l’écrou à oreille et en faisant pivoter le carré
interne du cadre. Resserrer les pinces de
l’écrou à oreille une fois en position adéquate.
directives pour les applications de cadres de montage isolés/étanches à lair
Directives pour toutes les applications
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Tab
T-Bar
Fig.C
Vue à l’intérieur de la boîte de jonctionConnecteur(s) de conduit de
tal 1/2 po avec écrou à oreille
© 2016 Philips Lighting Holding B.V. Tous droits résers.
Philips se réserve le droit de changer les spécications
et/ou de discontinuer tout produit et en tout temps sans
préavis et ne pourra être tenu responsable pour toutes
conquences résultant de l’utilisation de cette publication.
philips.com/luminaires
Philips Lighting, North America Corporation
200 Franklin Square Drive, Somerset, NJ 08873
Téléphone : 855-486-2216
Philips Éclairage Canada Ltée
281 Hillmount Rd, Markham, ON, Canada L6C 2S3
Téléphone : 800-668-9008
Étape 1
Faire pivoter les extrémités de la barre à charnière tel qu’illustré (Fig.C) et rallonger complètement les
barres. Sertir la bordure inférieure du prolé an d’empêcher les extrémités de la barre à charnière de
pivoter (Fig.B).
Étape 2
Placer les zones entaillées des barres de
montage sur le prolé en T et verrouiller en
pliant la languette sous le prolé en T tel
qu’illustré (Fig.C).
Étape 3
Ajuster le luminaire à la position recherce
le long de la barre de montage et verrouiller
en place à l’aide de la vis de blocage.
Étape 4
Eectuer les connexions en suivant les
directives ci-dessous.
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Connecteur
du conduit
Avant
Arrre
Fig.D
Plaque
de connexion
d’alimentation
Diamètre
complet arrière
Bague de percée
(ou ruban
électrique si un
diamètre à fond
de let n’est pas
utilisé)
Fils
d’alimentation
Fig.E
Étape 1
Les cadres orent un joint d’étanchéité qui
scellent toute ouverture entre le dessous du
cadre et le matériau du plafond. Si le dessus
du matériau du plafond n'est pas plat, utilisez
un calfeutrage silicone pour sceller toutes
les lacunes. Deux bagues de percée sont
également incluses pour sceller les connexions
des ls d’alimentation.
Étape 2
Acheminer les ls d’alimentation dans le
connecteur de 1/2 po. Conduit de métal avec
ouverture arrière à diamètre à fond de let
et écrou à oreille peuvent être utilisés (Fig.D).
Tous les connecteurs de conduit de métal.
Étape 3
Rattacher le connecteur sur la plaque de
connexion. Percer la bague en poussant les
ls au centre ou percer avant à l’aide d’un
clou au diamètre plus petit que celui du l
(Fig E).
Étape 4
Glisser la bague sur les ls d’alimentation
jusqu’à ce quelle s’insère complètement
dans le connecteur Resserer la (es) vis du
connecteur pour le rattacher adéquatement
sur le conduit de l d’alimentation. Si un
connecteur de conduit sans ouverture
à diamètre à fond de let est utili, un
ruban électrique peut entourer les ls
d’alimentation pour sceller les ouvertures.
ceiling plate
ceiling adapter
decorative nut
(reflector mount only)
decorative plate
(ceiling mount only)
CEILING
Sertir ici
Montage
bar canal
Fig.B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

dans d''autres langues