VESA Mounting (optional)
The stand for the TLP 700TV can be removed and replaced with the Extron
VM700Tkit (part #70-692-01). This bracket (see gure 7) ts into any
third-party VESATypeD75mm wall mount system. For more information,
see the instructions that come with the VM700Tkit.
2.95”
2.95”
Figure 7. VMT Vesa Mount Bracket
Setup Screen
1. Use a paper clip to press the recessed menu button (see gure 1,
8
). This opens
the setup menu at the Main setup page (see gure 8).
2. Touch an area of the screen to bring it into focus and use the up and down buttons
or the volume control knob to adjust the value. Some options have a single button
and toggle between Off and On when pressed.
Use the different screen menus to adjust the following options. For more details, see
the TLP 700MV and TLP 700TV User Guide, which is available at www.extron.com.
• Main (see gure 8) — This screen is used to adjust the Sleep timer, Backlight,
Auto Backlight, LED Backlight, and Wake on Motion functions.
• Volume — This screen is used to adjust the Master, Click, Sounds, and Line In
volume settings.
• Time — This screen is used to set up the correct time and date.
• Network — This screen is used to set the IP Address, the Subnet Mask, and to
enable or disable Dynamic Host Conguration Protocol (DHCP).
• Video — This screen provides a small video preview window and the controls to
set up the video Contrast, Color, Brightness, and Tint.
Calibration Screen
While in the Setup menu, press the Menu button a second time to open the calibration
screen (see gure
9
). When all four points have been calibrated, the screen reopens to
the Setup screen.
Press Exit to close the on-screen menus.
Figure 8. Setup Menu
Reset Modes
The four reset modes can be initiated by using a paperclip to press the Reset button (see gure 1,
9
, on page 1).
NOTE: See the TLP 700MV and TLP 700TV User Guide at www.extron.com for additional details.
• Factory Firmware Mode — Hold the Reset button while applying power to reset the unit back to the base rmware shipped with
the unit.
• Run/Stop Events Mode — Hold the Reset button until the reset LED blinks once (3 seconds), then release and press Reset
momentarily (less than 1 second) within 1 second.
This mode turns events on or off.
• Reset All IP Settings Mode — Hold the Reset button until the reset LED blinks twice (6 seconds), then release and press
Reset momentarily (less than 1 second) within 1 second.
This mode resets the IP address, subnet, gateway, port mapping, and DHCP settings back to factory defaults. The reset LED
blinks 4 times in quick succession, conrming the reset and turning events off. If necessary, reset the IP address, using ARP and
the MAC address.
• Reset Factory Defaults Mode — Hold the Reset button until the reset LED blinks 3 times (9 seconds), then release and press
Reset momentarily (less than 1 second) within 1 second.
This mode causes a reset to factory defaults for everything except rmware.
NOTES:
• The factory congured passwords for all accounts on this device have been set to the device serial number. Passwords
are case sensitive.
• If the device is reset to default settings, the password will be the default password conguration. The default password
is extron.
Figure 9. Calibration Screen
Configuring the TLP 700TV (Initial Setup)
Before using the TLP 700TV, congure it, using the on screen menus. Five
different screens (Main, Volume, Time, Network, and Video) can be selected
by pressing the appropriate button at the left side of the screen. Press the
Exit button in the bottom left corner to close the menus.
3
Product Category