DeWalt D55167 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur

Ce manuel convient également à

D55167
Oil-Free Portable Air Compressor
Compresseur d’air portatif sans huile
Compresor de aire sin aceite portátil
INSTRUCTION MANUAL
GUIDE D'UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA
DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-De
2

A. Auto(I)/Off(O) Switch
B. Air Tank Pressure Gauge
C. Regulated Pressure Gauge
D. Regulator
E. Quick Connect

Voltage: Single Phase 120V
Minimum branch circuit requirement: 15 A
Fuse Type: Time delay

MODEL
D55167
WEIGHT
85 lbs. (38.6 kg)
HEIGHT
27.5" (698.5 mm)
WIDTH
18.0" (457.2 mm)
LENGTH
21.25" (539.8 mm)
AIR TANK CAPACITY
15 gallons (56.8 liters)
APPROX CUT-IN PRESSURE
160 psi
APPROX. CUT-OUT PRESSURE
200 psi
SCFM @ 90 PSI
4.8 *
NOISE LEVEL
79 dBA
+
*Tested per ISO 1217:1996
+Tested per ISO 3744:1994

F. Check Valve
G. Safety Valve
H. Air Tank Drain Valve
(not shown)
I. Pressure Switch
J. Air Intake Filter


Noise Emission Values
Sound Pressure Level: LpA = 79.0 dBA re 20μPA
Uncertainty in the Sound Pressure Level: KpA = 3.0 dBA re 20μPA
Sound Power Level: LwA = 93.0 dBA re 1 pw
Uncertainty in the Sound Power Level: KwA = 3.0 dBA re 1 pw
The sum of the emission value and the uncertainty is the limit
below which there is a 95% confidence the value of a single tool
will lie below when the tool is new.
FIG. 1
A
E
C
B
D
I
F
J
G
3


The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to
these symbols.
DANGER: Indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
CAUTION: Indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury
which, if not avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT
THIS OR ANY D
e
WALT TOOL, CALL US TOLL FREE AT:
1-800-4-D
e
WALT (1-800-433-9258)

WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
WARNING: This product contains chemicals known to the State
of California to cause cancer, and birth defects or other reproductive
harm. Wash hands after handling.
WARNING: Some dust contains chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm
such as asbestos and lead in lead based paint.

DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Itisnormalforelectricalcon-
tacts within the motor and
pressure switch to spark.
• Alwaysoperatethecompres-
sor in a well ventilated area
free of combustible materials,
gasoline, or solvent vapors.
• Ifelectricalsparksfrom
compressor come into con-
tact with flammable vapors,
they may ignite, causing fire
or explosion.
• Ifsprayingflammablemateri-
als, locate compressor at
least 20 feet (6.1 m) away
from spray area. An addi-
tional length of hose may be
required.
• Storeflammablematerialsin
a secure location away from
compressor.
4

• Restrictinganyofthe
compressor ventilation
openings will cause serious
overheating and could
cause fire.
• Neverplaceobjectsagainstor
on top of compressor.
• Operatecompressorin
an open area at least 12"
(30.5 cm) away from any
wall or obstruction that would
restrict the flow of fresh air to
the ventilation openings.
• Operatecompressorina
clean, dry well ventilated area.
Do not operate unit indoors or
in any confined area.
• Unattendedoperationof
this product could result in
personalinjuryorproperty
damage. To reduce the risk
of fire, do not allow the
compressor to operate unat-
tended.
• Alwaysremaininattendance
with the product when it is
operating.
• Alwaysturnoffandunplug
unit when not in use.
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN HOW TO PREVENT IT
• Thecompressedairdirectly
from your compressor is not
safe for breathing. The air
stream may contain carbon
monoxide, toxic vapors,
or solid particles from the
air tank. Breathing these
contaminants can cause
seriousinjuryordeath.
• Neveruseairobtaineddirectly
from the compressor to supply
air for human consumption.
The compressor is not
equipped with suitable filters
and in-line safety equipment
for human consumption.
• Exposuretochemicals
in dust created by
power sanding, sawing,
grinding, drilling, and other
construction activities may
be harmful.
• Sprayedmaterialssuchas
paint, paint solvents, paint
remover, insecticides, weed
killers, may contain harmful
vapors and poisons.
• Workinanareawithgood
cross ventilation. Read and
follow the safety instructions
provided on the label or
safety data sheets for the
materials you are spraying.
Always use certified safety
equipment: NIOSH/OSHA
respiratory protection or
properly fit ting face mask
designed for use with your
specific application.
5

WARNING: RISK OF BURSTING
Air Tank: On February 26, 2002, the U.S. Consumer Product
Safety Commission published Release # 02-108 concerning air
compressor tank safety:
Air compressor receiver tanks do not have an infinite life. Tank life
is dependent upon several factors, some of which include operat-
ing conditions, ambient conditions, proper installations, field modi-
fications, and the level of maintenance. The exact effect of these
factors on air receiver life is difficult to predict.
If proper maintenance procedures are not followed, internal corro-
sion to the inner wall of the air receiver tank can cause the air tank
to unexpectedly rupture allowing pressurized air to suddenly and
forcefullyescape,posingriskofinjurytoconsumers.
Your compressor air tank must be removed from service by the end
of the year shown on your tank warning label.
The following conditions could lead to a weakening of the air tank,
and result in a violent air tank explosion:
WHAT CAN HAPPEN HOW TO PREVENT IT
• Failuretoproperlydrain
condensed water from
air tank, causing rust and
thinning of the steel air tank.
• Drainairtankdailyorafter
each use. If air tank develops
a leak, replace it immediately
with a new air tank or replace
the entire compressor.
• Modificationsorattempted
repairs to the air tank.
• Neverdrillinto,weld,ormake
any modifications to the air
tank or its attachments. Never
attempt to repair a damaged or
leaking air tank. Replace with a
new air tank.
• Unauthorizedmodificationsto
the safety valve or any other
components which control air
tank pressure.
• Theairtankisdesigned
to withstand specific
operating pressures. Never
makeadjustmentsorparts
substitutions to alter the factory
set operating pressures.
Attachments & accessories:
• Exceedingthepressure
rating of air tools, spray guns,
air operated accessories,
tires, and other inflatables
can cause them to explode or
fly apart, and could result in
seriousinjury.
• Followtheequipment
manufacturers
recommendation and never
exceed the maximum allowable
pressure rating of attachments.
Never use compressor to
inflate small low pressure
objectssuchaschildren’stoys,
footballs, basketballs, etc.
6

TIres:
• Over inflation of tires could
resultinseriousinjuryand
property damage.
• Useatirepressuregaugeto
check the tires pressure before
each use and while inflating
tires; see the tire sidewall for
the correct tire pressure.
NOTE:
Air tanks, compressors
and similar equipment used to
inflate tires can fill small tires
veryrapidly.Adjustpressure
regulator on air supply to no
more than the rating of the tire
pressure. Add air in small incre-
ments and frequently use the tire
gauge to prevent over inflation.
WARNING: RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN HOW TO PREVENT IT
• Your air compressor is
powered by electricity.
Like any other electrically
powered device, If it is not
used properly it may cause
electric shock.
• Never operate the compressor
outdoors when it is raining or
in wet conditions.
• Never operate compressor
with protective covers
removed or damaged.
• Repairs attempted by
unqualified personnel can
resultinseriousinjuryor
death by electrocution.
• Any electrical wiring or
repairs required on this
product should be performed
by a D
eWALT factory
service center or a D
eWALT
authorized service center in
accordance with national and
local electrical codes.
• Electrical Grounding:
Failure to provide adequate
grounding to this product
couldresultinseriousinjury
or death from electrocution.
See Grounding
Instructions under
Installation.
• Make certain that the
electrical circuit to which the
compressor is connected
provides proper electrical
grounding, correct voltage and
adequate fuse protection.
WARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• Thecompressedairstream
can cause soft tissue
damage to exposed skin and
can propel dirt, chips, loose
particles,andsmallobjects
at high speed, resulting in
property damage or personal
injury.
• Always wear certified safety
equipment: ANSI Z87.1 eye
protection (CAN/CSA Z94.3)
with side shields when using
the compressor.
• Neverpointanynozzleor
sprayer toward any part of
the body or at other people or
animals.
7

• Alwaysturnthecompressoroff
and bleed pressure from the
air hose and air tank before
attempting maintenance,
attaching tools or accessories.
WARNING: RISK OF HOT SURFACES
WHAT CAN HAPPEN HOW TO PREVENT IT
• Touchingexposedmetalsuch
as the compressor head,
engine head, engine exhaust
or outlet tubes, can result in
serious burns.
• Nevertouchanyexposed
metal parts on compressor
during or immediately after
operation. Compressor will
remain hot for several minutes
after operation.
• Donotreacharound
protective shrouds or attempt
maintenance until unit has
been allowed to cool.
WARNING: RISK FROM MOVING PARTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• Movingpartssuchasthe
pulley, flywheel, and belt can
causeseriousinjuryifthey
come into contact with you or
your clothing.
• Neveroperatethecompressor
with guards or covers which
are damaged or removed.
• Keepyourhair,clothing,and
gloves away from moving parts.
Looseclothes,jewelry,orlong
hair can be caught in moving
parts.
• Airventsmaycovermoving
parts and should be avoided as
well.
• Attemptingtooperate
compressor with damaged or
missing parts or attempting
to repair compressor with
protective shrouds removed
can expose you to moving
parts and can result in
seriousinjury.
• Anyrepairsrequiredonthis
product should be performed
by a D
eWALT factory service
center or a D
eWALT authorized
service center.
8

WARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN HOW TO PREVENT IT
• Unsafeoperationofyourair
compressor could lead to
seriousinjuryordeathtoyou
or others.
• Reviewandunderstandall
instructions and warnings in
this manual.
• Becomefamiliarwiththe
op eration and con trols of the
air compressor.
• Keepoperatingareaclearofall
persons, pets, and obstacles.
• Keepchildrenawayfromtheair
compressor at all times.
• Donotoperatetheproduct
when fatigued or under the
influence of alcohol or drugs.
Stay alert at all times.
• Neverdefeatthesafetyfea
tures of this prod uct.
• Equipareaofoperationwitha
fire extinguisher.
• Donotoperatemachinewith
missing, broken, or un au tho-
rized parts.
WARNING: RISK OF FALLING
WHAT CAN HAPPEN HOW TO PREVENT IT
• Aportablecompressor
can fall from a table,
workbench, or roof causing
damage to the compressor
and could result in serious
injuryordeathtothe
operator.
• Alwaysoperatecompressorina
stable secure position to prevent
accidental movement of the unit.
Never operate compressor on a
roof or other elevated position.
Use additional air hose to reach
high locations.
WARNING: RISK OF INJURY FROM LIFTING
WHAT CAN HAPPEN HOW TO PREVENT IT
• Seriousinjurycanresult
from attempting to lift too
heavyanobject.
•The compressor is too heavy
to be lifted by one person.
Obtain assistance from
others before lifting.
CAUTION: RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Under some conditionsand
duration of use, noise from
this product may contribute
to hearing loss.
• Alwayswearcertifiedsafety
equipment: ANSI S12.6
(S3.19) hearing protection.
9




AUTO/OFF SWITCH
Place this switch (A) in the AUTO (I)
F
A
I
position to provide automatic power
to the pressure switch and OFF (O)
to remove power at the end of each
use.
PRESSURE SWITCH
The pressure switch (I) automatically starts the motor when the
air tank pressure drops below the factory set cut-in pressure. It
stops the motor when the air tank pressure reaches the factory set
cut-out pressure.
SAFETY VALVE
If the pressure switch does not
C
D
B
G
E
shut off the air compressor at its
cut-out pressure setting, the safety
valve (G) will protect against high
pressure by popping out at its
factory set pressure (slightly higher
than the pressure switch cut-out
setting).
CHECK VALVE
When the air compressor is operating, the check valve (F) is
open, allowing compressed air to enter the air tank. When the
air compressor reaches cut-out pressure, the check valve closes,
allowing air pressure to remain inside the air tank.
TANK PRESSURE GAUGE
The tank pressure gauge (B) indicates the reserve air pressure in
the tank.
REGULATED PRESSURE GAUGE
The outlet pressure gauge (C) indicates the air pressure available
at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure.
REGULATOR
The regulator (D) controls the air pressure shown on the regulated
pressure gauge. Pull the knob out and turn clockwise to increase
pressure and counterclockwise to decrease pressure. When the
desired pressure is reached push knob in to lock in place.
UNIVERSAL QUICK CONNECT BODY
The universal quick connect body (E) accepts the three most
popular styles of quick connect plugs: Industrial, automotive, and
ARO. One hand push-to-connect operation makes connections
simple and easy.
DRAIN VALVE
The drain valve (H) is located at the base of the air
DRAIN TANK DA ILY
H
tank and is used to drain condensation at the end
of each use.
See Draining Air Tank under
Maintenance.
COOLING SYSTEM
This compressor contains an advanced design cooling system.
It is normal for this fan to blow air through the vent holes in large
amounts. The cooling system is working when air is expelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not
available until the compressor has raised the air tank pressure
above that required at the air outlet.
10

AIR INTAKE FILTER
The filter (J) is designed to clean air entering the pump. To ensure
the pump continually receives a clean, cool, and dry air supply the
filter must always be clean and the filter intake must be free from
obstructions.
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector. If the motor overheats
for any reason, the overload protector will shut off the motor. The
motor must be allowed to cool down before restarting. To restart:
1. Set the Auto/Off lever to OFF and unplug unit.
2. Allow the motor to cool.
3.
Plug the power cord into the correct branch circuit receptacle.
4. Set the Auto/Off lever to AUTO position.


INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Grasp the hose at the quick connect plug and push the plug
into the quick connect body (E). Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Pull coupler on quick connect body back to release Quick
Connect plug on hose.

WARNING: Risk of Electrical Shock. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (M) with this unit
L
M
K
contains a grounding pin (L). This plug
MUST be used with a grounded
outlet (K).
IMPORTANT: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
DANGER: Risk of Electrical Shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
• Donotmodifytheplugprovided.Ifitdoesnotfittheavailable
outlet, a correct outlet should be installed by a qualified
electrician.
• RepairstothecordsetorplugMUSTbemadebyaqualified
electrician.
11


If an extension cord must be used, be sure it is:
• a3wireextensioncordthathasa3bladegroundingplug,and
a 3-slot receptacle that will accept the plug on the product
•ingoodcondition
•nolongerthan50feet(15.2m)
• 12 gauge (AWG) or larger. (Wire size increases as gauge
number decreases. 10 AWG and 8 AWG may also be used. DO
NOT USE 14 OR 16 AWG.)
NOTICE: The use of an undersized extension cord will cause
voltage to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of
the air hose by attaching another length of hose to its end. Attach
additional lengths of hose as needed. Always use a minimum 3/8"
(9.5 mm) or greater air hose rated at 300 psi.

Refer to the Voltage and Minimum Branch Circuit Requirements
under Pump/Motor Specifications.
CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
• Voltage supply to circuit must comply with the National
Electrical Code.
• Circuitisnotusedtosupplyanyotherelectricalneeds.
• Extensioncordscomplywithspecifications.
• Circuitisequippedwitha15ampcircuitbreakeror15amp
time delay fuse. NOTE: If compressor is connected to a circuit
protected by fuses, use only time delay fuses. Time delay
fuses should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the
compressor repeatedly causes interruption of the power, it may be
necessary to operate it from a 20 amp circuit. It is not necessary
to change the cord set.

NOTE: Always use an air line filter to remove moisture and oil vapor
when spraying paint.

Place the air compressor in a clean, dry and well ventilated area
at least 12" (30.5 cm) away from the wall or other obstructions that
will interfere with the flow of air. Keep the compressor away from
areas that have dirt and/or volatile fumes in the atmosphere. These
impurities may clog the intake filter and valves, causing inefficient
operation.
WARNING: The air compressor pump and shroud are designed to
allow for proper cooling. The ventilation openings on the compressor
are necessary to maintain proper operating temperature. Do not
place rags or other containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber
feet and wheels.
ELECTRICAL
Refer to all safety instructions before using unit. Observe extension
cord safety instructions if necessary. Always move the Auto/Off
switch (A) to the OFF position before removing the plug from the
outlet.
TRANSPORTING
When transporting the compressor in a vehicle, trailer, etc., make
sure the tank is drained and the unit is secured with straps to prevent
tipping. Use care when driving to prevent tipping the unit over in the
vehicle. Damage can occur to the compressor or surrounding items
if the compressor is tipped.
12

LIFTING
Always use two people when lifting and lift from
N
N
the recommended lift points (N). DO NOT lift
by wheels or shroud.
MOVING
CAUTION: The wheels and handle do
not provide adequate clearance, stability, or
support for pulling the unit up and down stairs or steps. The unit
must be lifted or pushed up a ramp.
1. Grasp handle of compressor and tilt compressor back to rest on
wheels.
WARNING: Risk of Unsafe Operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
2. When location is reached slowly lower compressor to ground.
Always store compressor in a horizontal position resting
on the rubber bumpers and wheels.

WARNING: Do not operate this unit until you read this instruction
manual for safety, operation and maintenance instructions.

1.
Ensure the Auto/Off switch (A) is in the OFF position.
2.
Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Pull the regulator knob (D) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
7. Attach hose and accessories. NOTE: Always use a minimum
3/8" (9.5 mm) or greater air hose rated at 300 psi.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
WARNING:
Risk of unsafe operation. Do not use damaged or
worn accessories.
WARNING: Risk of Bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.


1. Follow Pre-Start Checklist under Preparation for Use.
2. Move the Auto/Off switch to the AUTO position and allow tank
pressure to build. Motor will stop when tank pressure reaches
cut-out pressure.
NOTICE: Risk of property damage. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un fil-
tered air at an item that could be damaged by moisture. Some air
op er ated tools or de vic es may require filtered air. Read the in struc-
tions for the air tool or device.
3.Adjust regulator (D) to desired setting. See Regulator under
Features.

1. Move Auto/Off switch (A) to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
13

2. Pull the regulator knob (D) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.

The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure Auto/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should
be performed by a D
e
WALT factory service center or a D
e
WALT
authorized service center.

Procedure Daily Weekly
See tank
warning
label
Check safety valve
X
Inspect air filter
X
Drain air tank
X
Check for unusual noise/vibration
X
Check for air leaks
X
1
Clean compressor exterior
X
Remove tank from service
X
2
1Tocheckforairleaksapplyasolutionofsoapywateraroundjoints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
2 - For more information, call 1-800-4-D
e
WALT (1-800-433-9258)

WARNING: Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
WARNING: Risk from flying objects. Always wear certified safety
equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side
shields when using the compressor.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. NOTE: Ring may
be difficult to pull when air tank pressure is at 0 psi. If the valve is
stuck or does not operate smoothly, it must be replaced with the
same type of valve.
14


WARNING: Risk of unsafe operation. Risk from noise. Air tanks
contain high pressure air. Keep face and other body parts away from
outlet of drain. Use eye protection [ANSI Z87.1 (CAN/CSA Z94.3)]
when draining as debris can be kicked up into face.
WARNING: Risk from noise. Use ear protection [ANSI S12.6
(S3.19)] as air flow noise is loud when draining.
NOTE: All compressed air systems generate condensate that
accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers).
This condensate contains lubricating oil and/or substances which
may be regulated and must be disposed of in accordance with local,
state, and federal laws and regulations.
1. Ensure Auto/Off switch is in the OFF position.
2. Place a suitable container under the drain valve (H) to catch
discharge.
3. Grasp lever on drain valve.
4. Slowly rotate lever to gradually bleed air from air tank.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
NOTICE: Risk of property damage. Drain water from air tank may
contain oil and rust, which can cause stains.
5. When air tank pressure gauge reads 10 psi, rotate valve to the
fully open position.
6. Close drain valve when finished.

WARNING: Hot surfaces. Risk of burn. Outlet tube, pump head,
and surrounding parts are very hot, do not touch. Allow compressor
to cool prior to servicing.
1. Ensure Auto/Off switch (A) is in the OFF Position.
2. Allow unit to cool.
3. Remove filter cover (J) from base.
4. Remove element from filter base.
J
5. Place new element back in filter
base. Purchase replacement parts
from your local dealer or authorized
service center. Always use identical
replacement parts.
6. Snap filter cover to filter base.
NOTICE: Risk of unsafe operation. Do not operate without air inlet
filter

Recommended accessories for use with your tool are available
for purchase from your local dealer or authorized service center.
If you need assistance in locating any accessory for your tool,
please contact D
e
WALT Industrial Tool Co., 701 East Joppa Road,
Baltimore, MD 21286, call 1-800-4-D
e
WALT (1-800-433-9258) or visit
our website www.dewalt.com.
WARNING: The use of any other accessory not recommended for
use with this tool could be hazardous. Use only accessories rated
equal to or higher than the rating of the air compressor.

Please have the following information available for all service calls:
Model Number ____________ Serial Number _________________
Date and Place of Purchase ______________________________

To assure product SAFETY and RELIABILITY, repairs, maintenance
andadjustmentshouldbeperformedbyaD
e
WALT factory service
center, a D
e
WALT authorized service center or other qualified
service personnel. Always use identical replacement parts.
15


DeWALT heavy duty industrial tools are warranted for one year from
date of purchase. We will repair, without charge, any defects due
to faulty materials or workmanship. For warranty repair information,
call 1-800-4-D
e
WALT (1-800-433-9258). This warranty does not
apply to accessories or damage caused where repairs have been
made or attempted by others. This warranty gives you specific legal
rights and you may have other rights which vary in certain states or
provinces.
LATIN AMERICA: This warranty does not apply to products sold
in Latin America. For products sold in Latin America, see country
specific warranty information contained either in the packaging, call
the local company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning
labels become illegible or are missing, call 1-800-4-D
e
WALT
(1-800-433-9258) for a free replacement.
WARNING
DRAIN TANK D AILY
OR AFTER EVERY 4 HOURS OF USE. CONDENSATION BUILD-UP MAY CAUSE
CORROSION INSIDE TANK RESULTING IN TANK FAILURE. SEE MANUAL FOR INSPECTION PROCEDURES.
TO DRAIN TANK OPEN V A LVE SLOWLY AND TILT COMPRESSOR TO EMPTY ACCUMULATED W A TER.
ADVERTENCIA
DRENE EL TANQUE A DIARIO O DESPUÉS DE CAD A 4 HORAS DE USO. LA ACUMULACIÓN DE
CONDENSACIÓN PUEDE OCASIONAR CORROSIÓN DENTRO DEL TANQUE Y PROVOCAR FA LLA DEL
TANQUE. CONSULTE EL MANUAL P A RA CONOCER LOS PROCEDIMIENTOS DE INSPECCIÓN. P A RA DRENAR EL TANQUE, ABRA LA
VÁ LVULA LENT A MENTE E INCLINE EL COMPRESOR P A RAELIMINAR EL AGUA ACUMULAD A.
AVERTISSEMENT
RÉSERVOIR DE VIDANGE QUOTIDIEN OU APRÈS TOUTES LES 4 HEURES D'UTILISATION.
L'HABILLAGE DE CONDENSATION PEUT CAUSER LA CO RROSION À L'INTÉRIEUR DU RÉSERVOIR A Y ANT
POUR RÉSUL T A T L'ÉCHEC DE RÉSERVOIR. VOIR LE MANUEL POUR DES PROCÉDURES D'INSPECTION. À LA V A L V E
OUVERTE DE RÉSERVOIR DE VIDANGE LENTEMENT ET A U CO MPRESSEUR D'INCLINAISON À L ' EAU ACCUMULÉE VIDE.
WARNING
HOT SURF A CES
ADVERTENCIA
SUPERFICIES CALIENTES
AVERTISSEMENT SURFACES CHAUDES
DO NOT ADJUST F A CTORY SETTINGS.
TO REDUCE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER.
Pressure c ontrols set at factory for
maximum safe operation.
NO H AGA CAM BIO S E N LOS AJ UST ES
DE FÁ BRIC A. NO RET IRE LA T A P A P A RA
REDU CIR EL RIE SGO DE CHO QUE EL ÉCT RICO .
Los c ontr ole s d e pr esi ón s e a jus tan en la
fábr ica pa ra m áxi ma segu rid ad en l a o pera ció n.
ADVERTENCIA
WARNING
AVERTISSEMENT

CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air
delivery.
PSI: Pounds per square inch; a unit of measure of pressure.
Code Certification: Products that bear one or more of the
following marks: UL
®
*, CUL, ETL
®
*, CETL, have been evaluated
by OSHA certified independent safety laboratories and meet the
applicable Standards for Safety.
* UL
®
is a registered trademark of Underwriters Laboratories
and ETL
®
is a registered trademark of Electrical Testing
Laboratories.
Cut-In Pressure: While the motor is off, air tank pressure drops
when accessory is used. When the tank pressure drops to a certain
low level the motor will restart automatically. The low pressure at
which the motor automatically restarts is called cut-in pressure.
Cut-Out Pressure: When an air compressor is turned on and
begins to run, air pressure in the air tank begins to build. It builds
to a certain high pressure before the motor automatically shuts
off, protecting your air tank from pressure higher than its capacity.
The high pressure at which the motor shuts off is called cut-out
pressure.
Branch Circuit: The circuit carrying electricity from electrical
panel to outlet.
Duty Cycle: This air compressor pump is capable of running
continuously. However, to prolong the life of your air compressor,
it is recommended that a 50%-75% average duty cycle be
maintained; that is, the air compressor pump should not run more
than 30-45 minutes in any given hour.
16


This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance
personnel can perform some corrective actions, and others may require the assistance of a qualified D
eWALT technician or your dealer.
Problem Code
Excessive air tank pressure-safety valve pops off ......................................................................1, 2
Air leaks ....................................................................................................................................3
Air leaks in air tank or at air tank welds ....................................................................................4
Air leaks between head and valve plate ....................................................................................5
Air leaks from safety valve .........................................................................................................6
Knocking Noise ..........................................................................................................................6
Pressure reading on the regulated pressure gauge drops when an accessory is used ...........7
Compressor is not supplying enough air to operate accessories..............................................8, 9, 10, 11, 12, 22
Regulator knob has continuous air leak ....................................................................................13
Regulator will not shut off air outlet ...........................................................................................13
Motor will not run .......................................................................................................................6, 14, 15, 16, 17, 18, 19, 20
Squealing Sound .......................................................................................................................21

CODE POSSIBLE CAUSE POSSIBLE SOLUTION
1 Pressure switch does not shut off motor when
compressor reaches cut-out pressure
Set the Auto/Off switch to OFF, if the unit does not shut off contact
a D
e
WALT factory service center or a D
e
WALT authorized service
center.
2 Pressure switch cut-out too high Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
3 Tube fittings are not tight enough Tighten fittings where air can be heard escaping. Check fittings
with soapy water solution. Do Not Overtighten.
17

CODE POSSIBLE CAUSE POSSIBLE SOLUTION
4 Defective air tank Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or other-
wise modify air tank or it will weaken. The air tank can rupture or
explode.
5 Leaking seals Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
6 Defective safety valve Operate safety valve manually by pulling on ring. If valve still leaks,
it must be replaced.
7
Regulatorisnotadjustedcorrectlyforaccessory
being used
It is normal for some pressure drop to occur when an accessory
isused,adjusttheregulatorasinstructedinRegulator under
Features if pressure drop is excessive.
NOTE:Adjusttheregulatedpressureunderflowconditionswhile
accessory is being used.
8 Prolonged excessive use of air Decrease amount of air usage.
9 Compressor is not large enough for accessory Check the accessory air requirement. If it is higher than the CFM
or pressure supplied by your air compressor, a larger compressor
is needed to operate accessory.
10 Hole in air hose Replace air hose.
11 Check valve restricted Remove, clean or replace.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace.
14 Motor overload protection switch has tripped Refer to Motor Overload Protection under Features. If motor over-
load protection trips frequently, contact a D
e
WALT factory service
center or a D
e
WALT authorized service center.
18

CODE POSSIBLE CAUSE POSSIBLE SOLUTION
15 Tank pressure exceeds pressure switch cut-in
pressure
Motor will start automatically when tank pressure drops below cut-
in pressure of pressure switch.
16 Extension cord is wrong length or gauge Check for proper gauge wire and cord length refer to the Extension
Cords under Installation.
17 Loose electrical connections Check wiring connection inside pressure switch and terminal box
area.
18 Possible defective motor Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
19 Paint spray on internal motor parts Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center. Do not operate the compressor in the paint spray
area. See Risk of Explosion or Fire warning under Important
Safety Instructions.
20 Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary. Reset
circuit breaker. Do not use a fuse or circuit breaker with higher
rating than that specified for our particular branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate
the compressor on its own branch circuit.
21 Worn Belt Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
22 Restricted air intake filter Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenance section.
19


A. Interrupteur Auto(I)/Arrêt (O)
B.Manomètreduréservoird’air
C. Manomètre régulé
D. Régulateur
E. Branchements rapides
F. Clapet
G. Soupape de sûreté
H. Soupape de purge du
réservoird’air(nonmontré)
I. Rembobineur de cordon
d’alimentation
J. Filtred’admissiond’air

Tension : monophasé, 120V
Exigence minimale du circuit de dérivation : 15 A
Type de fusible : temporisation

MODÈLE
D55167
POIDS
38,6 kg (85 livres)
HAUTEUR
698,5 mm (27,5 po)
LARGEUR
457,2 mm (18,0 po)
LONGUEUR
539,8 mm (21,25 po)
CAPACITÉ DU RÉSERVOIR D’AIR
56,8 liters (15 gallons)
PRESSION D’ENCLENCHEMENT
APPROX.
160 psi
ENV. PRESSION DE DÉCLENCHEMENT
200 psi
PCMS (SCFM) @ 90 PSI
4,8 *
NIVEAU SONORE
79 dBA
+
*Testé conformément à la norme ISO 1217
+ Testé conformément à la norme ISO 3744


Valeur de l’émission de bruits
Niveau de pression acoustique : LpA = 79,0 dBA re 20μPA
Incertitude du niveau de
pression acoustique calculé : KpA = 3,0 dBA re 20μPA
Niveau de puissance acoustique : LwA = 93,0 dBA re 1 pw
Incertitude du niveau de puissance
acoustique : KwA = 3,0 dBA re 1 pw
Lasommedelavaleurdel’émissionetdel’incertitudeétablitla
limite sous laquelle la valeur pour un seul outil y sera inférieure et
ce, à 95 % de fiabilité statistique.
FIG. 1
A
E
C
B
D
I
F
J
20



Les définitions ci-dessous décrivent le niveau de gravité pour
chaque symbole. Veuillez lire le mode d’emploi et porter une
attention particulière à ces symboles.
DANGER : Indique une situation dangereuse imminente qui, si
elle n’est pas évitée, causera la mort ou des blessures graves.
AVERTISSEMENT :
Indique une situation potentiellement
dangereuse qui, si elle n’est pas évitée, pourrait se solder par un
décès ou des blessures graves.
ATTENTION : Indique une situation potentiellement dangereuse
qui, si elle n’est pas évitée pourrait se solder par des blessures
mineures ou modérées.
AVIS : Indique une pratique ne posant aucun risque de
dommages corporels mais qui par contre, si rien n’est fait pour
l’éviter, pourrait poser des risques de dommages matériels.
POUR TOUTES QUESTIONS OU COMMENTAIRES RELATIFS(VES)
À L’OUTIL OU À PROPOS DE TOUT AUTRE OUTIL D
eWA LT,
COMPOSER SANS FRAIS LE : 1-800-4-D
eWA LT (1-800-433-9258)

AVERTISSEMENT : Ne pas utiliser cet appareil avant d’avoir lu
et compris le mode d’emploi ainsi que l’intégralité des directives de
sécurité, d’utilisation et d’entretien.
AVERTISSEMENT :
Ce produit contient des produits chimiques
reconnus par l’État de la Californie comme étant cancérigènes
et pouvant entraîner des anomalies congénitales ou d’autres
problèmes liés aux fonctions reproductrices. Se laver les mains
après toute manipulation.
AVERTISSEMENT :
Certaines poussières contiennent des
produits chimiques reconnus par l’État de la Californie comme
cancérigènes et pouvant entraîner des anomalies congénitales
et d’autres problèmes liés aux fonctions reproductrices, tels que
l’amiante et le plomb contenus dans les peintures au plomb.

DANGER :
RISQUE D’EXPLOSION OU D’INCENDIE
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
• Ilestnormalquedes
contacts électriques dans le
moteur et le manocontacteur
fassent une étincelle.
• Faitestoujoursfonctionner
le compresseur dans une
zone bien aérée sans matière
combustible, essence ou
vapeur de solvant.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

DeWalt D55167 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues