Lincoln Electric Ranger 8 Mode d'emploi

Catégorie
Système de soudage
Taper
Mode d'emploi
RANGER
8
OPERATOR’S MANUAL
For Machines with Code Numbers 10908, 10935, 10998
IM752-A
January, 2003
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
R
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Date of Purchase:
Serial Number:
Code Number:
Model:
Where Purchased:
Copyright © 2003 Lincoln Global Inc.
This manual covers equipment which is no
longer in production by The Lincoln Electric Co.
Specications and availability of optional
features may have changed.
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
Mar ‘95
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines
The Above For Gasoline Engines
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases.When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and below Threshold Limit Values (TLV)
using local exhaust or mechanical ventilation. In
confined spaces or in some circumstances, outdoors, a
respirator may be required. Additional precautions are
also required when welding on galvanized steel.
5.b.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating prod-
ucts.
5.c. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
iii
SAFETY
iii
Mar ‘95
WELDING SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode s’applicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de n’importe quelle partie
du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray-
onnement de l’arc et des projections quand on soude ou
quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de
l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de
soudage. Se protéger avec des vêtements de protection libres
de l’huile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible
de la zone de travail qu’il est pratique de le faire. Si on place
la masse sur la charpente de la construction ou d’autres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques d’incendie ou d’echauffement des chaines et des
câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
d’opérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
l’électricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch-
er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
Mar. ‘93
Thank You
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or
loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to
this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Model Name & Number _____________________________________
Code & Serial Number _____________________________________
Date of Purchase _____________________________________
Whenever you request replacement parts for or information on this equipment always supply the information
you have recorded above.
vv
vi
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications ................................................................................................A-1,A-2
Installation Instructions.........................................................................................................A-3
Safety Precautions ........................................................................................................A-3
Machine Grounding.......................................................................................................A-3
Spark Arrester ...............................................................................................................A-3
Trailers ..........................................................................................................................A-3
Pre-Operation Engine Service..............................................................................................A-4
Oil..................................................................................................................................A-4
Fuel ...............................................................................................................................A-4
Battery Connections......................................................................................................A-4
Welding Cable Connections..........................................................................................A-4
Angle of Operation ........................................................................................................A-5
High Altitude Operation .................................................................................................A-5
Location and Ventilation................................................................................................A-5
Welding Cable Connections..........................................................................................A-5
Connection of Wire Feeders .........................................................................................A-5
Connection of Tig Module .............................................................................................A-6
Additional Safety Precautions,Welding Operation Output.............................................A-6
Auxiliary Power Receptacles, and Plugs ......................................................................A-6,A-7
Motor Starting.......................................................................................................................A-7
Electrical Device Used with the Ranger 8 ............................................................................A-8
Auxiliary Power While Welding,Standby Power Connections .............................................A-9
Premises Wiring .................................................................................................................A-10
Operation.........................................................................................................................Section B
General Description..............................................................................................................B-1
Design Features ...................................................................................................................B-1
Other Features .....................................................................................................................B-1
Engine Options.....................................................................................................................B-1
Fuel Consumption ................................................................................................................B-2
Controls and Settings ...........................................................................................................B-2
Welder / Generator Controls...................................................................................B-2,B-3
Engine Operation .................................................................................................................B-3
Starting the Engine........................................................................................................B-3
Safety Precautions ........................................................................................................B-3
Stopping the Engine......................................................................................................B-3
Break-In Period .............................................................................................................B-3
Welding Process ..................................................................................................................B-4
Stick (Constant Current) Welding..................................................................................B-4
TIG (Constant Current) Welding ...................................................................................B-4
DC Wire Feed Welding Processes(CV) .......................................................................B-4
Summary of Welding Processes ..................................................................................B-5
Accessories.....................................................................................................Section C
General Options / Accessories..............................................................................C-1
Recommended Equipment/ Accessories...............................................................C-2
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Engine Maintenance ..........................................................................D-1,D2
Engine Adjustments...............................................................................................D-3
Slip Rings ..............................................................................................................D-3
Battery Maintenance .......................................................................................D-3
Engine Maintenance Parts..............................................................................D-3
Troubleshooting..............................................................................................Section E
Safety Precautions.................................................................................................E-1
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide...................................................................................E-2, E-3
Wiring Diagrams & Dimension Print..............................................................Section F
Parts List..................................................................................................................P229
A-1
INSTALLATION
RANGER 8
A-1
* Based on a 10 min. period.
TECHNICAL SPECIFICATIONS - Ranger 8 (K1418-3 CSA MEETS CANADIAN STD.)
(K1419-3 CSA MEETS CANADIAN STD.)
(K2160-1 CSA MEETS CANADIAN STD.)
INPUT - GASOLINE ENGINE
RATED OUTPUT - WELDER
HEIGHT WIDTH DEPTH WEIGHT
30.3 in. 19.2 in. 42.3 in. 529 lbs. (240kg.) K1418-3
770 mm 488 mm 1074 mm 511 lbs. (232kg.) K1419-3 &
K2160-2
OUTPUT - GENERATOR
Welding Output *
AC Constant Current 225A / 25V / 100%
DC Constant Current 210A / 25V / 100%
DC Constant Voltage 200A / 20V / 100%
Auxiliary Power
8,000 Watts, 60 Hz AC
40 Amps @ 115V(40 Amps @ duplex outlets)
35 Amps @ 230V
PHYSICAL DIMENSIONS
Make/Model
Onan P220
(K1418-3)
Kohler CH20
(K1419-3)
Honda
GX620KI
(K2160-2)
Description
2 cylinder
4 Cycle
Air-Cooled
Gasoline
Engine.
Aluminum Alloy
with Cast Iron
Liners, Electrical
Ignition
Speed (RPM)
High Idle 3700
Full Load 3500
Low Idle 2200
Displacement
cu. in. (cu. cm.)
39.9(653)-Onan
38(624)-Kohler
37.5(614)-Honda
Capacities
Fuel:
9 Gal (34 L)
Lubricating Oil:
1.6 Qts (1.5 L)
Fuel:
9 Gal (34 L)
Lubricating Oil:
2.0 Qts (1.9 L)
Fuel:
9 Gal (34 L)
Lubricating Oil:
1.9 Qts (1.8 L)
Horsepower
20.5 HP @
3600 RPM
(Onan)
20 HP @
3600 RPM
(Kohler)
20 HP @
3600 RPM
(Honda)
A-2
INSTALLATION
RANGER 8
A-2
AC STICK / TIG (CC) OUTPUT
A 225 OUTPUT RANGE
B 50 OUTPUT RANGE
A
B
OUTPUT AMPS
OUTPUT VOLTS AC (RMS)
0
50 100 150 200
250
0
10
20
30
40
50
60
70
80
DC STICK / TIG (CC) OUTPUT
OUTPUT AMPS
OUTPUT VOLTS DC (RMS)
A 210 OUTPUT RANGE
B 50 OUTPUT RANGE
A
B
0
50 100 150
200 250 300
350
0
10
20
30
40
50
60
70
80
CV OUTPUT RANGE
0
50
100
150
200
250 300
OUTPUT AMPS
350
0
5
10
15
20
25
30
35
40
DC WIRE FEED (CV) OUTPUT
OUTPUT VOLTS DC (RMS)
SPECIFICATIONS
A-3
INSTALLATION
RANGER 8
A-3
INSTALLATION INSTRUCTIONS
SAFETY PRECAUTIONS
MACHINE GROUNDING
Because this portable engine driven welder or genera-
tor creates it’s own power, it is not necessary to con-
nect it’s frame to an earth ground, unless the machine
is connected to premises wiring (your home, shop,
etc.).
To prevent dangerous electric shock, other equipment
to which this engine driven welder supplies power
must:
be grounded to the frame of the welder using a
grounded type plug, or
be double insulated.
When this welder is mounted on a truck or trailer, it’s
frame must be securely connected to the metal frame
of the vehicle.
Where this engine driven welder is connected to
premises wiring such as that in your home or shop, it’s
frame must be connected to the system earth ground.
See further connection instructions in the section enti-
tled “Standby Power Connections”, as well as the arti-
cle on grounding in the latest U.S. National Electrical
Code and the local code.
In general, if the machine is to be grounded, it should
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into
the ground for at least ten feet and having no insulat-
ed joints, or to the metal framework of a building
which has been effectively grounded. The U.S.
National Electrical Code lists a number of alternate
means of grounding electrical equipment. A machine
grounding stud marked with the symbol is provid-
ed on the front of the welder.
SPARK ARRESTER
Some federal, state, or local laws may require that
gasoline engines be equipped with exhaust spark
arresters when they are operated in certain locations
where unarrested sparks may present a fire hazard.
The standard muffler included with this welder does
not qualify as a spark arrester. When required by
local regulations, the K894-1 spark arrester must be
installed and properly maintained.
An incorrect arrester may lead to damage to the
engine or adversely affect performance.
------------------------------------------------------------------------
TRAILERS
The recommended trailer for use with this equipment
for in plant and yard towing by a vehicle is Lincoln’s
K768-2. Consult applicable federal, state, and local
laws regarding specific requirements for use on public
highways.
If the user adapts a non-Lincoln trailer, he must
assume responsibility that the method of attachment
and usage does not result in a safety hazard nor dam-
age the welding equipment.
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturers
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and
ground
Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
Do not operate with doors open or
guards off.
Stop engine before servicing.
Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at
front of this operators manual.
-----------------------------------------------------------
WARNING
CAUTION
A-4
INSTALLATION
RANGER 8
A-4
Some of the factors to be considered are as follows:
1. Design capacity of trailer vs. weight of Lincoln
equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of
the welding equipment so there will be no undue
stress to the framework.
PRE-OPERATION SERVICE
READ the engine operating and maintenance instruc-
tions supplied with this machine.
OIL
The Ranger 8 is shipped with the engine crankcase
filled with SAE 10W-30 oil. Check the oil level before
starting the engine. If it is not up to the full mark on
the dip stick, add oil as required. Make certain that
the oil filler cap is tightened securely. Refer to the
engine Owner’s Manual for specific oil recommenda-
tions.
FUEL
Fill the fuel tank with clean, fresh, lead-free gasoline.
Observe fuel gauge while filling to prevent overfilling.
BATTERY CONNECTIONS
This welder is shipped with the negative battery cable
disconnected. Make sure that the Engine Switch is in
the “STOP” position and attach the disconnected
cable securely to the negative battery terminal before
attempting to operate the machine. If the battery is
discharged and does not have enough power to start
the engine, see the battery charging instructions in the
Battery section.
WELDING OUTPUT CABLES
With the engine off, connect the electrode and work
cables to the studs provided. These connections
should be checked periodically and tightened if neces-
sary. Loose connections will result in overheating of
the output studs.
When welding at a considerable distance from the
welder, be sure you use ample size welding cables.
Listed below are copper cable sizes recommended for
the rated current and duty cycle. Lengths stipulated
are the distance from the welder to work and back to
the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable voltage drop.
CAUTION
GASOLINE
fuel can cause fire or
explosion.
-
• Stop engine while fueling.
• Do not smoke when fueling.
• Do not overfill tank.
• Keep sparks and flame away from tank.
• Wipe up spilled fuel and allow fumes to clear
before starting engine.
------------------------------------------------------------------------
WARNING
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
0-50 Ft.
50-100 Ft.
100-150 Ft.
150-200 Ft.
200-250 Ft.
225 Amps
40% Duty Cycle
3 AWG
3 AWG
2 AWG
1 AWG
1/0 AWG
225 Amps
100% Duty Cycle
1 AWG
1 AWG
1 AWG
1 AWG
1/0 AWG
LUBRICATION SYSTEM CAPACITY
(INCLUDING FILTER)
Onan P220 - 1.6 Quarts (1.5 Liters)
Kohler CH20S - 2.0 Quarts (1.9 Liters)
Honda GX620KI-1.9Quarts (1.8 Liters)
A-5
INSTALLATION
RANGER 8
A-5
ANGLE OF OPERATION
Internal combustion engines are designed to run in a
level condition which is where the optimum perfor-
mance is achieved. The maximum angle of operation
for the engine is 15 degrees from horizontal in any
direction. If the engine is to be operated at an angle,
provisions must be made for checking and maintain-
ing the oil at the normal (FULL) oil capacity in the
crankcase in a level condition.
When operating at an angle, the effective fuel capaci-
ty will be slightly less than the specified 9 gallons.
HIGH ALTITUDE OPERATION
If the Ranger 8 will be consistently operated at alti-
tudes above 5000 ft, a carburetor jet designed for
high altitudes should be installed. This will result in
better fuel economy, cleaner exhaust, and longer
spark plug life. It will not
give increased power which
is decreased at higher altitudes. Engine horsepower
is reduced by 3.5% per 1000 feet for altitudes above
377 feet.
Do not operate a Ranger 8 with a high altitude jet
installed at altitudes below 5000 ft. This will
result in the engine running too lean and result in
higher engine operating temperatures which can
shorten engine life.
Contact your local Onan, Kohler or Honda Authorized
Dealer for high altitude jet kits that are available from
the engine manufacturer.
Muffler Relocation Shut off welder and allow
muffler to cool before touching muffler.
The Ranger 8 is shipped with the exhaust coming out
on the left side. The exhaust can be changed to the
opposite side by removing the two screws that hold
the exhaust port cover in place and installing the
cover on the opposite side. (Operating the Ranger 8
without the cover in place will result in a higher noise
level and no increase in machine output.)
LOCATION / VENTILATION
The welder should be located to provide an unrestrict-
ed flow of clean, cool air to the cooling air inlets and to
avoid heated air coming out of the welder recirculating
back to the cooling air inlet. Also, locate the welder
so that engine exhaust fumes are properly vented to
an outside area.
CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS
Shut off welder before making any electrical
connections.
WIRE FEED (CONSTANT VOLTAGE)
CONNECTION OF THE LN-25 TO THE RANGER 8
Shut the welder off.
Connect the electrode cable from the LN-25 to the
“ELECTRODE” terminal of the welder. Connect
the work cable to the “TO WORK” terminal of the
welder.
Position the welder “Polarity” switch to the desired
polarity, either DC (-) or DC (+).
Position the “RANGE” switch to the “WIRE FEED”
position.
Attach the single lead from the LN-25 control box
to the work using the spring clip on the end of the
lead - it carries no welding current.
Place the idler switch in the “AUTO” position.
Adjust wire feed speed at the LN-25 and adjust
the welding voltage with the output “CONTROL”
at the welder.
NOTE: The welding electrode is energized at all
times, unless an LN-25 with built-in contactor is used.
If the output “CONTROL” is set below “3”, the LN-25
contactor may not pull in.
CAUTION
WARNING
Damage to the fuel tank may cause
fire or explosion. Do not
drill holes
in the Ranger 8 base or weld to the
Ranger 8 base.
WARNING
WARNING
A-6
INSTALLATION
RANGER 8
A-6
CONNECTION OF THE LN-7 TO THE RANGER 8
Shut the welder off.
Connect the LN-7 and the K240 contactor kit per
instructions on the connection diagram S17742
(can be found in the back of this manual).
Place the “RANGE” switch to the “WIRE FEED”
position and the “POLARITY” switch to the
desired polarity.
Place the “IDLER” switch in the “HIGH” idle
position. The engine idling device may not
function when welding in the “WIRE FEED” mode.
Adjust wire feed speed at the LN-7 and adjust the
welding voltage with the output “CONTROL” at
the welder.
NOTE: If the output “CONTROL” is set below “3” the
K240 contactor may not pull in.
CONNECTION OF K930-[ ] TIG MODULE
TO THE RANGER 8.
The TIG Module is an accessory that provides high
frequency and shielding gas control for AC and DC
GTAW (TIG) welding. See IM528 supplied with the
TIG Module for installation instructions.
Note: The TIG Module does not require the use of a
high frequency bypass capacitor. However, if the
Ranger 8 is used with any other high frequency equip-
ment, the bypass capacitor must be installed - order
kit T12246.
INSTRUCTIONS
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the roof and case
sides in place as this provides maximum protection
from moving parts and assures proper cooling air
flow.
Read and understand all Safety Precautions before
operating this machine. Always follow these and any
other safety procedures included in this manual and in
the Engine Owner’s Manual.
WELDER OPERATION
WELDER OUTPUT
• Maximum Open Circuit Voltage at 3700 RPM is
80 Volts RMS.
• Duty Cycle: 100% for both welding and auxiliary
power.
AUXILIARY POWER
The Ranger 8 can provide up to 8,000 watts of
115/230 volts AC, single phase 60Hz power for con-
tinuous use. The front of the machine includes three
receptacles for connecting the AC power plugs; one
50 amp 115/230 volt NEMA 14-50R receptacle and
two 20 amp 115 volt NEMA 5-20R receptacles.
Do not connect any plugs that connect to the
power receptacles in parallel.
------------------------------------------------------------------------
Start the engine and set the “IDLER” control switch to
the desired operating mode. Set the “CONTROL” to
10. Voltage is now correct at the receptacles for auxil-
iary power.
115/230 VOLT DUAL VOLTAGE RECEPTACLE
The 115/230 volt receptacle can supply up to 40 amps
of 230 volt power to a two wire circuit, up to 40 amps
of 115 volts power from each side of a three wire cir-
cuit (up to 70 amps total). Do not connect the 115 volt
circuits in parallel. Current sensing for the automatic
idle feature is only in one leg of the three wire circuit
as shown in the following column.
Ranger 8
Constant Current 225 Amps AC @ 25 Volts
210 Amps DC @ 25 Volts
Constant Voltage 200 Amps DC @ 20 Volts
CAUTION
A-7
INSTALLATION
RANGER 8
A-7
115 V DUPLEX RECEPTACLES
The 115V auxiliary power receptacles should only be
used with three wire grounded type plugs or approved
double insulated tools with two wire plugs.
The current rating of any plug used with the system
must be at least equal to the current load through the
associated receptacle (Refer to Tables I and II). Do
not attempt to connect power receptacles in parallel.
MOTOR STARTING
Most 1.5 hp AC single phase motors can be started if
there is no load on the motor or other load connected
to the machine, since the full load current rating of a
1.5 hp motor is approximately 20 amperes (10
amperes for 230 volt motors). The motor may be run
at full load when plugged into only one side of the
duplex receptacle. Larger motors through 2 hp can be
run provided the receptacle rating as previously stated
is not exceeded. This may necessitate 230V opera-
tion only.
GND
115 V
115 V*
230 V
*Current Sensing for Automatic Idle.
(Receptacle viewed from front of Machine)
Load From
115V/230V
Dual Voltage Total From Total From
Receptacle Each 115V Both 115V
Duplex Duplexes
0 20 40*
2.0 KW 20 40*
4.0 KW 20 40*
6.0 KW 20 20*
8.0 KW 0 0
TABLE II Maximum Current Draw from 115V GFCI
Duplex Receptacles - No Welding
*Maximum current draw from each 115V
GFCI Duplex is 20 amps
Load From
115V/230V
Dual Voltage Total From Total From
Receptacle Each 115V Both 115V
Duplex Duplexes
0 20* 40
2.0 KW 20* 40
4.0 KW 20* 40
6.0 KW 20* 20
8.0 KW 0 0
TABLE I Maximum Current Draw from 115V Duplex Receptacles - No Welding
*NEMA 5-20P Plug required for 20Amp Draw
A-8
INSTALLATION
RANGER 8
A-8
TABLE lll
ELECTRICAL DEVICE USE WITH THE RANGER 8.
Type Common Electrical Devices Possible Concerns
Resistive Heaters, toasters, incandescent NONE
light bulbs, electric range, hot
pan, skillet, coffee maker.
Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage
appliances with electrical control. regulation can cause the capac-
itative elements to fail. Surge
protection, transient protection,
and additional loading is recom-
mended for 100% fail-safe
operation. DO NOT RUN
THESE DEVICES WITHOUT
ADDITIONAL RESISTIVE TYPE
LOADS.
Inductive Single-phase induction motors, These devices require large
drills, well pumps, grinders, small current inrush for starting.
refrigerators, weed and hedge Some synchronous motors may
trimmers be frequency sensitive to attain
maximum output torque, but
they SHOULD BE SAFE from
any frequency induced failures.
Capacitive/Inductive Computers, high resolution TV sets, An inductive type line condition-
complicated electrical equipment. er along with transient and
surge protection is required,
and liabilities still exist. DO
NOT USE THESE DEVICES
WITH A RANGER 8
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect-
ed to the RANGER 8.
A-9
INSTALLATION
RANGER 8
A-9
STANDBY POWER CONNECTIONS
The Ranger 8 is suitable for temporary, standby, or
emergency power using the engine manufacturers rec-
ommended maintenance schedule.
The Ranger 8 can be permanently installed as a stand-
by power unit for 230V-3 wire, single phase 35 ampere
service.
(Connections must be made by a licensed electri-
cian who can determine how the 115/230V power
can be adapted to the particular installation and
comply with all applicable electrical codes.) The
following information can be used as a guide by
the electrician for most applications (refer also to
the connection diagram shown in Figure 1.)
-------------------------------------------------------------------------
1. Install a double pole, double throw switch between
the power company meter and the premises
disconnect.
Switch rating must be the same or greater than
the customers premises disconnect and service
overcurrent protection.
2. Take necessary steps to assure load is limited to
the capacity of the Ranger 8 by installing a 35 amp
230V double pole circuit breaker. Maximum
rated load for the 230V auxiliary is 35 amperes.
Loading above 35 amperes will reduce output
voltage below the allowable -10% of rated
voltage which may damage appliances or other
motor-driven equipment.
3. Install a 50 amp 115/230V plug (NEMA type 14-50)
to the Double Pole Circuit Breaker using No. 8,
4 conductor cable of the desired length. (The
50 amp 115/230V plug is available in the
optional plug kit.)
4. Plug this cable into the 50 amp 115/230V
receptacle on the Ranger 8 case front.
WARNING
AUXILIARY POWER WHILE WELDING
Simultaneous welding and power loads are permitted
by following Table I. The permissible currents shown
assume that current is being drawn from either the
115V or 230V supply (not both at the same time).
Also, the Output Control is set at 10 for maximum
auxiliary power.
TABLE I
SIMULTANEOUS WELDING AND POWER
Output Selector Permissible Power Permissible Auxiliary
Setting Watts (Unity Power Current in Amperes
Factor) @ 115V
*-or- @ 230V
Max. Stick or Wire
Feed Setting None 0 0
175 Stick Setting 2100 18 9
125 Stick Setting 3800 32 16
90 Stick Setting 5000 42
** 21
70 Stick Setting 5600 48
** 24
50 Stick Setting 6300 54
** 27
NO WELDING 8000 70
** 35
* Each duplex receptacle is limited to 20 amps.
**Not to exceed 35A per 115VAC branch circuit when
splitting the 230 VAC output.
A-10
INSTALLATION
RANGER 8
A-10
Connection of Ranger 8 to premises wiring must
be done by a licensed electrician and must com-
ply with the National Electrical Code and all other
applicable electrical codes.
230 Volt
60 Hz.
3-Wire
Service
POWER
COMPANY
METER
230 VOLT
115 VOLT
115 VOLT
LOAD
N
NEUTRAL
BUS
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
GND
N
NOTE: No. 8 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
SIZE RECOMMENDATIONS.
230 VOLT
GROUNDED CONDUCTOR
35AMP
230 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 115/230
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 115/230 VOLT
RECEPTACLE
Figure 1
CONNECTION OF RANGER 8 TO PREMISES WIRING
WARNING
B-1
OPERATION
RANGER 8
B-1
GENERAL DESCRIPTION
The Ranger
8 is a twin-cylinder, gasoline driven, mul-
tiprocess arc welder and AC power generator. It is
built in a heavy gauge steel case for durability on the
job site.
DESIGN FEATURES
AC/DC STICK WELDING (Constant Current)
AC 40 - 225 Amps
DC 40 - 210 Amps
100% Duty Cycle on All Settings
Output Selector with 6 Ranges
Output Control for Fine Current Adjustment
Use with a broad range of AC & DC Electrodes
Including Fleetweld® 5P
DC SEMIAUTOMATIC WIRE FEED WELDING
(Constant Voltage)
CV Tap Setting for 60-200 Amps.
100% Duty Cycle.
Excellent Performance with .068 (1.7mm)
NR®-211-MP Innershield® Electrode.
Limited MIG Welding with L-50 & L-56 using blended
Argon Shielding Gas.
The Recommended Wire Feeder is the LN-25, but
Can Also be Used with the LN-7 Wire Feeder.
(LN-7 and LN-25 without Contactor Requires the
K240 Contactor Kit).
AC/DC TIG WELDING (Constant Current)
AC & DC TIG Welding Can be Done at All Constant
Current Output Range Settings.
AC TIG welding requires TIG Module Option.
(See Accessories Section for TIG Module Options)
AUXILIARY POWER
8000 Watt AC 115/230 Volt 60 Hz. Generator.
Operates AC Power Tools.
Powers Battery Chargers.
Powers a 1.5 HP Motor (If Started Under No Load).
Lights Eighty 100 Watt Incandescent Bulbs.
Can be Used for Standby Power.
OTHER FEATURES
Bottom Mounted 9 Gallon Fuel Tank with a
Convenient Top Fill and Fuel Gauge.
Polarity Switch for Selecting DC+, DC-, or AC
Welding Output.
Electronic Engine Idler. Engine Automatically Goes to
Low Idle in 10 to 14 Seconds after Welding or Use
of Auxiliary Power. Includes High Idle Switch.
Electric Starting.
Battery Charging Ammeter.
Full 8 KVA Auxiliary Output Receptacle.
Factory Installed Engine Hour Meter.
Engine Protection Shuts Engine Down in the
Event of Low Oil Pressure.
Built-in Feet for Easy Mounting to Truck Bed or
Trailer.
All Copper Alternator Windings and High
Quality Insulation for Long-Life and
Dependability.
Powder Painted Case and Base for Outstanding
Corrosion Protection.
Quiet muffler with reversible exhaust feature; either
right or left side of machine.
ENGINE OPTIONS
Three Engines are available for the Ranger 8
Welders; the Onan P220, the Kohler 20 HP
Command®* and the Honda GX620KI. All three
engines have the following features:
Air Cooled, Twin-Cylinder.
Cast Aluminum Alloy Crankcase with Integral Cast
Iron Cylinder Liners.
Electric Start with Solid State Battery Charging
Module.
Solid State Breakerless Ignition.
Spin on Oil Filter.
Low Oil Pressure Shutdown Protection.
Overhead Valves & Hydraulic Valve Lifters.
* These trademarks are the property of their respec-
tive manufacturers.
HONDA
20 H.P. GX620KI
.3 Gallons/Hour
(1.3 Liters/Hour)
.7 Gallons/Hour
(2.7 Liters/Hour)
1.6 Gallons/Hour
(6.0 Liters/Hour)
1.7 Gallons/Hour
(6.3 Liters/Hour)
1.2 Gallons/Hour
(4.6 Liters/Hour)
1.5 Gallons/Hour
(5.7 Liters/Hour)
B-2
OPERATION
B-2
WELDER CONTROLS - FUNCTION AND OPERATION
ENGINE ON-OFF SWITCH
When placed in the ON position, this switch
energizes the engine ignition circuit. When placed in
the OFF position, the ignition circuit is de-energized
to shut down the engine.
ENGINE START PUSH-BUTTON SWITCH
Energizes engine starter motor.
POLARITY SWITCH
Never change the Polarity switch setting while
welding. This will damage the switch.
RANGE SWITCH
Never change the RANGE Switch setting while
welding. This will damage the switch.
CONTROL SWITCH
Provides a fine welding current adjustment within the
Range Switch settings in the STICK/TIG mode and
welding voltage control with the Range switch set in
the wire feed mode.
IDLER SWITCH
The idler switch has two positions, HIGH and
AUTO.
When in HIGH ( ) position, the engine will run
continuously at high idle.
When in AUTO ( / ) idle position, the idler
operates as follows:
Welding
When the electrode touches the work, the welding
arc is initiated and the engine accelerates to full
speed.
After welding ceases (and no auxiliary power is
being drawn), the engine will return to low idle
after approximately 10 to 14 seconds.
Auxiliary Power
With the engine running at low idle and auxiliary
power for lights or tools is drawn (approximately
100-150 watts or greater) from the receptacles,
the engine will accelerate to high speed. If no
power is being drawn from the receptacles (and
not welding) for 10-14 seconds, the idler reduces
the engine speed to low idle.
RANGER 8
Low Idle - No Load
2200 RPM
High Idle - No Load
3700 RPM
AC CC Weld Output
225 Amps @ 25 Volts
DC CC Weld Output
210 Amps @ 25 Volts
DC CV Weld Output
200 Amps @ 20 Volts
Auxiliary Power
8000 Watts
ONAN
20.5 H.P. P220
.6 Gallons/Hour
(2.3 Liters/Hour)
.8 Gallons/Hour
(3.0 Liters/Hour)
1.5 Gallons/Hour
(5.8 Liters/Hour)
1.6 Gallons/Hour
(6.1 Liters/Hour)
1.2 Gallons/Hour
(4.5Liters/Hour)
1.6Gallons/Hour
(6.1Liters/Hour)
KOHLER
20 H.P. COMMAND
.4 Gallons/Hour
(1.5 Liters/Hour)
.9 Gallons/Hour
(3.5 Liters/Hour)
1.3 Gallons/Hour
(5.0 Liters/Hour)
1.4 Gallons/Hour
(5.3 Liters/Hour)
1.2 Gallons/Hour
(4.5 Liters/Hour)
1.4 Gallons/Hour
(5.3 Liters/Hour)
RANGER 8 APPROXIMATE FUEL CONSUMPTION
ON
OFF
Explanation of Symbols that Appear on this Equipment
Low Idle
High Idle
CAUTION
STICK/TIG - CC 50, 70, 90
6 Range Settings 125, 175, 210 DC/225 AC
WIRE FEED - CV
1 Range Setting 200
Process Maximum Current
on Each Setting
CAUTION
B-3
OPERATION
B-3
STARTING/SHUTDOWN INSTRUCTIONS
STARTING THE ENGINE
Be sure all Pre-Operation Maintenance has been per-
formed. Also, read the Engine Owners Manual.
Remove all loads connected to the AC power recepta-
cles. To start the engine, set the Idler Control switch
in the Automatic ( / ) position.
Use the choke control as follows:
ONAN ENGINE - If the engine is cold, pull the choke
control out. Do not use the choke if the engine is
warm or hot.
KOHLER ENGINE - Always pull the choke control out
when starting the engine; cold, warm or hot. Place the
Engine switch in the ON position.
HONDA ENGINE - If the engine is cold, pull the choke
control out. Do not use the choke if the engine is
warm or hot. Place the Engine switch in the ON
position.
Push the START button and crank the engine until it
starts. Release the button as soon as the engine
starts. Do not push the START button while the
engine is running because this will cause damage to
the ring gear and/or starter motor. After the engine
has started, slowly return the choke control to the full
in position (choke open).
After running at high engine speed for 10-14 seconds,
the engine will go to low idle.
Allow the engine to warm up by letting it run at low idle
for a few minutes.
STOPPING THE ENGINE
Remove all welding and auxiliary power loads and
allow engine to run at low idle speed for a few minutes
to cool the engine.
Stop the engine by placing the Engine switch in the
OFF position.
A fuel shut off valve is not required on the Ranger 8
because the fuel tank is mounted below the engine.
BREAK-IN PERIOD
It is normal for any engine to use a greater amount of
oil until the break-in is accomplished. Check the oil
level twice a day during the break-in period (approxi-
mately 50 running hours)).
IMPORTANT: IN ORDER TO ACCOMPLISH THIS
BREAK-IN, THE UNIT SHOULD BE
SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF
THE MACHINE. AVOID LONG IDLE
RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO
COOL BEFORE SHUTDOWN.
The engine manufacturers recommendation for the
running time until the first oil change is as follows:
The oil filter is to be changed at the second oil
change. Refer to the Engine Owners Manual for more
information.
RANGER 8
Do not touch electrically live parts
of electrode with skin or wet
clothing.
Keep flammable material away.
Insulate yourself from work and
ground. Wear eye, ear, and body
protection.
Keep your head out of the fumes.
Use ventilation or exhaust to
remove fumes from breathing zone.
WARNING
Honda
GX620KI
First Month
or 20 HRS
Kohler
CH20S
5 HRS
Onan
P220
25 HRS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39

Lincoln Electric Ranger 8 Mode d'emploi

Catégorie
Système de soudage
Taper
Mode d'emploi

dans d''autres langues