SiXMEDICAL
1-Button Wireless Key
Installation Instructions
This bi-directional wireless key is intended for
use with Honeywell controls that support SiX™
series devices.
To activate, press and hold the button about 3
seconds until the LED flashes.
To clear the alarm
at the control, enter a user code. To clear
memory of alarm, select Disarm and enter a user
code.
The device can be used with a belt clip, lanyard,
or wristband.
[images of belt clip, wristband, necklace]
LED Indications
Green flashing: lights when unit is transmitting
Red Flashing: indicates low battery (lights
during key press)
Enroll and Program the SiXMEDICAL
For the Lyric™ Controller
Follow instructions in the Controller’s programming guide.
1. Set the Lyric Controller in Programming Mode: Security >
Tools > [installer code] > Program > (scroll down) > SiX
Programming.
2. Press and hold the button for about 3 seconds until the LED
flashes to activate the enrollment process.
3. The LED flashes green during enrollment (up to about 20
seconds).
NOTE: Enrollment time varies depending on the signal
strength between the device and the controller.
The device sends its unique MAC ID (Serial Number) and
Services information to the controller.
The controller registers the device and displays the
transmitter data on screen.
4. When done, the LED lights solid green for 3 seconds to
confirm enrollment.
If enrollment is not confirmed, press and hold the button again
for about 3 seconds to restart the enrollment process.
5. Press Edit to set the Alarm Report option on/off (if selected,
button press sends a report to the central station). Press
Save. Enter an appropriate Zone Descriptor. Press Save.
The device can also be manually enrolled. See the Controller’s
Programming Guide for details.
For the Lyric™ Gateway
Enroll and program using AlarmNet 360™.
For other Controls
For other Controls that support SiX Series devices, see the
controller’s instructions for enrollment details.
IMPORTANT: Once enrolled in a system, the SiXMEDICAL
cannot be used with another controller until it is removed from the
current controller. When removed from a system, the key fob will
revert to factory default settings.
Sensor Location Feature: To verify the location of each SiX
device in an installation, enter programming mode and select a
SiX device. The device LED lights. Select it again to turn the LED
off, or select the next device to locate.
After Enrolling: Verify adequate signal strength by conducting
Go/No Go tests (see controller’s instructions) with the device in
its intended mounting location. Adjust the device location as
necessary.
24-Hour Enrollment Deletion and Default
If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from the
unintended panel, reset the device to factory default
setting:
Press and hold the button for 15 seconds.
The device self-deletes from the panel it was enrolled in.
This procedure is available for 24 hours after enrollment
with a panel and the device remains powered (battery
installed).
Press and hold button 15 seconds.
Battery Replacement
When the battery is low, the LEDs do not flash during
transmission. To replace the battery:
1. Remove the screws from the back housing and use a
screwdriver to gently separate the front and back housings.
2. Use a screwdriver to carefully remove the battery.
3. Wait 10 seconds or press a key fob button for 2 seconds to
ensure full power discharge.
4. Insert a new 3V Coin Cell battery as shown. Recommended
replacement battery:
Recommended Batteries: 3V Coin Cell
Honeywell BL3-0004 (CR2450); Duracell DL2450;
Panasonic CR2450; Energizer CR2450
Replace the front housing and secure the housings with the
cover screw.
Replacing the Battery
BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge,
disassemble, heat above 212 F (100 C) or incinerate. Dispose of used
batteries properly. Keep away from children.
NOTE: Constant exposure to high or low temperature or high humidity
may reduce battery life.
Specifications
Battery: 1 x 3V Coin Cell, Honeywell BL3-0004 (CR2450); Duracell DL2450;
Panasonic CR2450; Energizer CR2450
RF Frequency: 2.4GHz
Operating Temperature: 0° to 50° C / 32° to 122° F
(Agency compliance 0° to 49° C / 32° to 120° F)
Relative Humidity: 95% max. (Agency compliance 93% max.),
non-condensing
Dimensions: 0.5” H x 1.5” L x 1.5” W / 13 mm H x 38 mm L x 38 mm W
Approval Listings:
FCC / IC
cETLus Listed
Conforms to UL 1023 & UL 985
Certified to ULC ORD- C1023
& ULC-S545
Other Standards:
SIA CP-01 RoHS C-Tick
Product must be tested at least once each year.
IMPORTANT! This wireless key is intended as a convenience to the user and should not be considered as a life safety device.
IMPORTANT SECURITY NOTICE
Please inform the User about the security importance of their wireless key (key fob), and what to do if it is lost.
Explain that the key fob is similar to their keys or access card. If lost or stolen, another person can compromise their security
system. They should immediately notify the Dealer/Installer of a lost or stolen key fob. The Dealer/Installer will then remove the
key fob programming from the security system.
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes
or modifications could void the user's authority to operate the equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant
une réception indésirable.
RF EXPOSURE
Warning The antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with
FCC and ISED multi-transmitter product procedures.
Mise en Garde
Exposition aux Fréquences Radio : La/les antenne(s) utilisée(s) pour cet émetteur ne pas être située(s) ni fonctionner parallèlement à tout autre transmetteur ou
antenne, excepté en conformité avec les procédures de produit multi transmetteur FCC et ISED.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR
DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Support and Warranty
For the latest documentation and online support information, please go to:
https://mywebtech.honeywell.com/
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa.
For patent information, see www.honeywell.com/patents MyWebTech Warranty Patents
2018 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.
DOC CODE 128B BAR CODE HERE
SiXMEDICAL 800-24147 4/18 Rev A