2
NAV 10E 401 D and NAV 10E 201 D • Setup Guide (Continued)
Indicators and buttons (see figure 1 on page 1)
E
Visible LEDs (LEDs that are always visible) —
• Power (PWR) — Indicates power and startup status.
Blinking — The unit is receiving power and is booting up.
Lit steadily — The unit is receiving power and is operational.
•
HDMI — The encoder is detecting an HDMI input.
• HDCP — The HDMI signal is HDCP encrypted.
• Stream (STRM)— Indicates the output status of the AV stream.
Lit steadily – The encoder is actively streaming a NAV output consisting of video, audio, or both.
Blinking – The encoder is actively streaming a NAV output, but network errors are present.
F
Hidden buttons and LEDs (features that are visible only when the faceplate is removed) —
• Reset button and LED — This recessed button and LED initiate and display three modes of reset (see the NAV 10E 401 D and
NAV 10E 201 D User Guide, available at
www.extron.com, for details).
• ID button and LED — The recessed ID button identifies the encoder when pressed. The LED blinks when the encoder is in
pairing mode (see
Pairing devices on front panel on page 7 for details).
• NAV 10G LEDs — Indicate the status of the network connection.
Link LED — Lit steadily indicates that a network link is established.
Act LED — Blinking indicates network trafc. The blink rate corresponds to activity.
Rear Panel Connectors
POWER
12V
2.0A MAX
Tx Rx S
G
G
CONTROL
RS-232 IR
NAV 10G
+
CCCBBB
Figure 2. NAV 10E 401 D and NAV 10E 201 D Rear
Panel Features
A
NAV 10G port — Connects to a LAN on which one or more
decoders also reside for streaming and control.
B
CONTROL RS-232/IR port — Connect a serial RS-232 signal,
a modulated IR signal, or both to this 3.5 mm, 5-pole
direct insertion connector for bidirectional RS-232 and IR
communication with connected remote controlled devices
using an Extron control system (see Control connector on
page 8 to wire the connector).
C
Power connector — Connect the included external 12 VDC power
supply into this 2-pole direct insertion connector for local power
(see
Power connector on page 8 to wire the connector).
Installation
Step 1: Prepare the Installation Site
ATTENTION:
•
Installation and service must be performed by authorized personnel only.
• L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
• Extron recommends installing the encoder into a grounded, UL Listed electrical junction box.
• Extron recommande d’installer le encoder dans une boîte de dérivation électrique mis à la terre, certifiée UL.
• If the encoder will be installed into fine furniture, it is best to hire a licenced, bonded craftsperson to cut the access
hole and perform the physical installation so the surface will not be damaged.
• S’il est prévu d’installer le encoder dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et
qualifié pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
• Follow all national and local building and electrical codes that apply to the installation site.
• Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.