Fire Magic Choice Multi-User and Accessible Post Grills Manuel utilisateur

Catégorie
Barbecues
Taper
Manuel utilisateur
1
IMPORTANT:
READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or the fire department.
WARNING:
1. Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
CODE AND SUPPLY REQUIREMENTS: This grill
must be installed in accordance with local codes
and ordinances, or, in the absence of local codes,
with either the latest National Fuel Gas Code
(ANSI Z223.1/NFPA 54), and Natural Gas and
Propane Storage and Handling Installation Code
(CSA-B149.1).
This appliance and its dedicated manual shutoff
valve must be disconnected from the gas-supply
piping system when testing the system at pressures
in excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas-supply
piping system by closing its dedicated manual
shutoff valve during any pressure testing of the gas-
supply system at pressures up to and including ½
psig (3.5 kPa).
All electrical outlets in the vicinity of the grill must be
properly grounded in accordance with local codes,
or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1, whichever is applicable.
Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
INSTALLER: Leave these instructions with consumer.
CONSUMER: Retain for future reference.
WARNING:
Improper installation, adjustment,
alteration, service, or maintenance can
cause injury or property damage. For
proper installation, refer to the installation
instructions. For assistance or additional
information, consult a qualified professional
service technician, service agency, or the
gas supplier.
SAFETY AND WARNING CODES
STAND-ALONE POST OUTDOOR
GAS GRILLS
INSTALLATION AND
OWNER’S MANUAL
Proper operation of your grill requires
prompt and periodic maintenance.
See the SERVICING AND CLEANING
section for details.
Certified to: ANSI Z21.58
CSA 1.6
US
®
C
Cooking Grid U.S. Patent
# D857,453
REV 0 - A - 1911211150
L-C2-604
CM(A)430s (IN-GROUND AND PATIO MOUNT)
CM430s patio
mount shown
2
IMPORTANT: LISEZ CES INSTRUCTIONS SOIGNEUSEMENT AVANT DE COMMENCER L’INSTALLATION OU L’UTILISATION
GRIL EXTÉRIEUR DE GAZ
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle flamme nue.
3. Ouvrez le couvercle si équipé d’un four.
4. Si l’odeur continue, gardez loin de
l’appareil et appelez immédiatement
votre département de fournisseur ou de
feu de gaz.
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas
l’essence ou d’autres vapeurs et liquides
inflammables à proximité de ceci ou
d’aucun autre appareil.
2. Un cylindre de propane non relié pour
l’usage ne sera pas stocké à proximité
de ceci ou d’aucun autre appareil.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances
locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre
le plus défunt Code national de gaz de carburant (norme ANSI
Z223.1/NFPA 54), et Stockage de gaz naturel et de propane
et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être
démontés du gaz-fournissent le système sifflant en examinant
le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système
sifflant par fermeture que ses différents robinets d’isolement
manuels pendant tous les essais sous pression du gaz-
fournissent le système aux pressions jusques et y compris
le ½ psig (kPa 3.5).
Toutes les sorties électriques à proximité du gril doivent être
correctement fondues selon des codes locaux, ou en l’absence
de local code, avec le code électrique national, ANSI/NFPA
70, ou le code électrique canadien, CSA C22.1, celui qui est
applicable.
Maintenez tout électrique-fournissent des cordes et carburant-
fournissent des tuyaux partis de n’importe quelle surface de
chauffage.
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le
changement, le service, ou l’entretien
peuvent causer des dommages ou des
dégats matériels. Référez-vous à ce manuel.
Pour de l'aide ou des renseignements
supplémentaires, consulter un technicien
professionnel qualifié de service, une
agence de service ou le fournisseur de gaz.
SÛRETÉ ET CODES D’AVERTISSEMENT
Ce gril est pour ultilisation à l’extérieur seulement.
Si l’appareil est entreposé à l’intérieur, enlever les
bouteilles et les laisser à l’extérieur.
Ne pas ranger le gril immédiatement aprés l’avoir utilisé.
le laisser refroidir avant de le déplacer ou de la ranger.
Le non respect de cette mesure de sécurité pourrait
entraîner un incendie causant des dommages à la
propriété, des blessures ou la mort.
Ne pas utiliser cet appareil sous une surface combustible.
Ne pas utiliser cet appareil sous un auvent. Le non
respect de cette mesure de sécurité pourrait entraîner
un incendie ou des blessures.
Dégagement minimal entre les parois latérales et l’arriére
de l’appareil et la construction combustible (45.7 cm à
partir des parois latérales et 45.7cm à partir de l’arriére).
Le régulareur de pression de gaz prévu avec cet appareil
de cuisson à gaz pour l’extérieur doit être utilisé. Ce
régulateur est réglé pour une pression de sortie de 5
pouces de colonne de l’eau pour le gaz naturel, et 10
pouces pour le propane.
LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ
POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE
CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS
GRAND QUE (LIVRES PAR POUCE CARRÉ), UN
RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ
AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS
D’OFFRE DE GAZ POUR LA PRESSION APPROPRIÉE
D’OFFRE DE GAZ.
Ne couvrez jamais la surface entière de cuisine ou de
gril de gauffreuses ou de casseroles. La surchauffe se
produira et les brûleurs ne seront pas très performants
quand la chaleur de combustion est emprisonnée au-
dessous de la surface à cuire.
Ne pulvérisez jamais l’eau sur une unité chaude de gaz,
comme ceci peut endommager des composants de
porcelaine ou de fer de fonte.
Une fuite de GPL peut causer une incendie ou une
explosion si enflammée entraînant des blessures
corporelles graves ou la mort.
Communiquez avec le fournisseur de GPL pour les
réparations ou pour disposer de qules bouteille ou du
GPL non utilisé.
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
Certifié à la norme: ANSI Z21.58 / CSA 1.6
REV 0 - A - 1911211150
L-C2-604
3
CONTENTS
GETTING STARTED
REV 0 - A - 1911211150
L-C2-604
GETTING STARTED
INSTALLATION, OPERATION, AND SAFETY INFORMATION ������������������������������������������������������������������������4
GAS SAFETY INFORMATION ��������������������������������������������������������������������������������������������������������������������������5
WARNING ���������������������������������������������������������������������������������������������������������������������������������������������������5
WHEN USING PROPANE GAS ������������������������������������������������������������������������������������������������������������������������5
WHEN USING NATURAL GAS ������������������������������������������������������������������������������������������������������������������������5
INSTALLATION SAFETY GUIDELINES�������������������������������������������������������������������������������������������������������������5
OPERATING THE UNIT SAFELY AND CORRECTLY ���������������������������������������������������������������������������������������5
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS ����������������������������������������������������������������������7
INSTALLATION REQUIREMENTS �������������������������������������������������������������������������������������������������������������������8
OVERHEAD CONSTRUCTION AND EXHAUST HOOD REQUIREMENTS ��������������������������������������������������������������8
REAR WALL CLEARANCES ����������������������������������������������������������������������������������������������������������������������������9
SIDE WALL / CORNER WALL CLEARANCES (if applicable) ���������������������������������������������������������������������������������9
COMBUSTION AIR AND COOLING AIRFLOW ����������������������������������������������������������������������������������������������� 10
GAS-SUPPLY PLUMBING REQUIREMENTS �������������������������������������������������������������������������������������������������� 10
MODEL SPECIFICATIONS ����������������������������������������������������������������������������������������������������������������������������� 11
REPLACEMENT PARTS LIST - CM GRILLS �������������������������������������������������������������������������������������������������� 13
REPLACEMENT PARTS LIST - CMA GRILLS ������������������������������������������������������������������������������������������������ 15
INSTALLATION
PATIO MOUNT INSTALLATION �������������������������������������������������������������������������������������������������������������������� 17
IN-GROUND POST INSTALLATION �������������������������������������������������������������������������������������������������������������� 19
INSTALL THE FLAVOR GRIDS ��������������������������������������������������������������������������������������������������������������������� 22
INSTALL THE COOKING GRIDS ������������������������������������������������������������������������������������������������������������������ 22
SECURE THE COOKING GRIDS ������������������������������������������������������������������������������������������������������������������ 22
LOCK THE CONTROL KNOBS ��������������������������������������������������������������������������������������������������������������������� 23
INSTALL THE DRIP TRAY ��������������������������������������������������������������������������������������������������������������������������� 24
INSTALL THE RIGID SHELVES �������������������������������������������������������������������������������������������������������������������� 24
INSTALL THE OVEN HOOD SIDE HANDLE KIT (CMA models only) ������������������������������������������������������������������ 24
USE, CARE, & SERVICE
IDENTIFICATION OF GRILL CONTROLS ����������������������������������������������������������������������������������������������������� 25
USING THE GRILL ���������������������������������������������������������������������������������������������������������������������������������������� 26
LIGHTING (IGNITION) INSTRUCTIONS ������������������������������������������������������������������������������������������������������� 27
ELECTRONIC LIGHTING ��������������������������������������������������������������������������������������������������������������������������� 27
MANUAL LIGHTING ���������������������������������������������������������������������������������������������������������������������������������� 27
SETTING THE TIMER �������������������������������������������������������������������������������������������������������������������������������� 27
SHUTTING OFF THE UNIT ������������������������������������������������������������������������������������������������������������������������� 27
SERVICING AND CLEANING ������������������������������������������������������������������������������������������������������������������������ 29
CLEANING YOUR GRILL ���������������������������������������������������������������������������������������������������������������������������� 29
CONTROL PANEL REMOVAL ���������������������������������������������������������������������������������������������������������������������� 31
COOKING GRID REMOVAL ������������������������������������������������������������������������������������������������������������������������ 32
BURNER REMOVAL ����������������������������������������������������������������������������������������������������������������������������������� 33
WARMING RACK REMOVAL ����������������������������������������������������������������������������������������������������������������������� 33
CONVERTING THE GAS TYPE �������������������������������������������������������������������������������������������������������������������� 34
BURNER AIR SHUTTER ADJUSTMENT �������������������������������������������������������������������������������������������������������� 35
VALVE "LOW" SETTING ADJUSTMENT �������������������������������������������������������������������������������������������������������� 36
TROUBLESHOOTING ������������������������������������������������������������������������������������������������������������������������������������ 37
WARRANTY �������������������������������������������������������������������������������������������������������������������������������������������������� 38
4
1. The outdoor appliance and surrounding area MUST
remain clear of flammable substances such as gasoline,
yard debris, wood, etc. Maintain a minimum horizontal
clearance of 18" (in all directions) from combustible
materials/items.
2. Do not block the 1" front air inlet along the bottom of
the control panel. See the COMBUSTION AIR AND
COOLING AIRFLOW section under INSTALLATION
REQUIREMENTS for details.
3. This unit must be installed so that the vent
openings and surrounding area of the grill remain
clear and free at all times. See the GAS SAFETY
INFORMATION section.
4. When using propane gas: the propane cylinder,
regulator, and rubber hose must be in a location
not subject to temperatures above 125° F (51° C).
5. The flames on each burner burn evenly along the
entire burner with a steady flame (mostly blue). If
burner flames are not normal, check and clean the
orifice and burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire beneath the
unit. A proper flame pattern will ensure safe operation
and optimal performance. Adjust the air shutter as
needed (see AIR SHUTTER ADJUSTMENT section).
6. The in-line gas valve or gas cylinder valve must always
be shut OFF when the unit is not in use.
7. The drip collector holes must be clear and unobstructed.
Excessive grease deposits can result in a grease fire.
8. Wear gloves and use extreme caution whenever
installing and handling this product and its accessories
as certain components have sharp edges that can
cause personal injury.
WARNING: NEVER cover more than 75% of the cooking or grill surface with griddles or pans. Overheating will occur,
and burners will not perform properly when combustion heat is trapped below the cooking surface.
IMPORTANT
IN THE EVENT OF A GREASE FIRE, IMMEDIATELY SHUT OFF THE MAIN GAS VALVE TO THE UNIT. KEEP THE LID
OPEN AND ALLOW THE FIRE TO EXTINGUISH ITSELF. KEEP AT A SAFE DISTANCE. A THOROUGH INSPECTION BY
A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN SHOULD BE CONDUCTED BEFORE FUTURE USE OF YOUR
UNIT. THE SERVICE TECHNICIAN WILL CHECK THE SYSTEM FOR GAS LEAKS AND WILL CHECK ALL ELECTRICAL
WIRING FOR DAMAGE. ALL GAS LEAKS AND WIRING MUST BE REPAIRED PRIOR TO FUTURE USE.
The unit serial number tag can be found affixed to the grill body behind the control panel (on an
aluminum tag) and on the underside of the drip tray handle (on a thermal label). It is recommended
that the drip tray first be removed and cleaned / emptied of its contents, then turned over to view.
The unit rating label is located inside of the control panel.
INSTALLATION, OPERATION, AND SAFETY INFORMATION
5
WARNING
This appliance MUST be installed and operated according to the information below.
FAILURE TO PROPERLY VENT THE PROPANE TANK MAY RESULT IN A FIRE OR EXPLOSION CAUSING
PROPERTY DAMAGE, BODILY INJURY, OR DEATH.
A leaking gas connection or valve unintentionally left open will create a hazard.
WHEN USING PROPANE GAS
Propane gas (also known as L.P. gas) is heavier than air and will accumulate or pool in an inadequately
vented area or recessed area.
If a pool of propane gas is ignited, an explosion will occur. Adequate venting at the floor level of the propane
tank eliminates this danger.
DO NOT store a spare propane-gas cylinder near the unit.
WHEN USING NATURAL GAS
Natural gas is lighter than air and will accumulate at the top of an inadequately vented area.
If an accumulation of natural gas is ignited, an explosion will occur. Adequate venting will eliminate this danger.
INSTALLATION SAFETY GUIDELINES
THIS UNIT MUST BE INSTALLED SO THAT THE AREA AROUND THE UNIT AND PROPANE TANK REMAIN
CLEAR AND FREE AT ALL TIMES.
The gas cylinder, regulator, and rubber hose must be in a location not subject to temperatures above
125° F (51° C).
IF A PROPANE CYLINDER IS INSTALLED, THE GUIDELINES FOUND IN THE SAFE USE & MAINTENANCE
OF PROPANE GAS CYLINDERS SECTION MUST BE FOLLOWED.
WHEN OPERATING THIS GAS APPLIANCE, ALL INSTRUCTIONS AND WARNINGS
MUST BE OBSERVED. FAILURE TO DO SO MAY RESULT IN A FIRE OR EXPLOSION
CAUSING PROPERTY DAMAGE, BODILY INJURY, OR DEATH.
Every time you use the unit, make sure that:
1. The area around the unit is clear and free from combustible materials, gasoline and flammable vapors/liquids.
2. There is no blockage of the airflow around the unit and propane tank.
3. The hose is inspected (if applicable). See SAFE USE & MAINTENANCE OF PROPANE-GAS CYLINDERS section.
DO NOT store any combustible materials, gasoline, and any other flammable vapors/liquids in the vicinity of the
unit. Provide adequate clearance for servicing and operation.
GAS SAFETY INFORMATION
OPERATING THE UNIT SAFELY AND CORRECTLY
6
U
L
Fig. 6-1 type coupleur de fil de point culminant d’I
Valve
de
décompression
QCC
Type 1
Valve
Ajustage de précision
en laiton de fil de
point culminant
Indicateur
de niveau
de liquide
(facultatif)
Écrou de main avec le
fil de point culminant.
Régulateur
Passage
Tuyau
Volant de commande
main dans le sens des aiguilles d’une montre pour engager les
fils et pour serrer jusqu’à ce que douillettement. L’utilisation des
pinces ou de la clé ne devrait pas être nécessaire. Seulement
le propane marqué par cylindres doit être employé.
Pour débrancher: Tournez l’écrou de main dans le sens
contraire des aiguilles d’une montre jusqu’à isolé (fig. 6-1).
Important: Avant d’employer le unité, et ensuite chaque
fois que le cylindre est enlevé et rattaché,
examinez tous les raccordements pour
déceler les fuites. Arrêtez les valves de unité
et ouvrez la valve principale de cylindre, puis
vérifiez les raccordements avec de l’eau
savonneux. Réparez toutes les fuites avant
d’allumer le unité.
ATTENTION: Tournez toujours la valve principale de cylindre
de propane au loin après chaque utilisation,
et avant de déplacer le unité et le cylindre, ou
débrancher l’accouplement. Cette valve doit
rester fermée et le cylindre a débranché alors
que l’appareil n’est pas en service, quoique
l’écoulement de gaz soit arrêté par un dispositif
de sûreté quand le coupleur est débranché.
Inspectez soigneusement l’ensemble de tuyau chaque fois
avant que le gaz soit allumé. Un tuyau fissuré ou effiloché doit
être immédiatement remplacé.
Si l'appareil est stocké à l'intérieur, le cylindre doit être disconnected
et a enlevé. Des cylindres Disconnected doivent être stockés
dehors, hors de la portée des enfants, avec les prises de valve
filetées étroitement installées, et ne doivent pas être stockés dans
un bâtiment, le garage, ou n'importe quel autre secteur inclus.
POUR VOTRE SÛRETÉ
a. Ne stockez pas un cylindre de gaz disponible de propane
dessous ou ne vous approchez pas de cet appareil.
b. Ne remplissez jamais cylindre au delà de 80 pour cent de
plein.
c. SI L’INFORMATION DANS “A” ET “B” N’EST PAS SUIVIE
EXACTEMENT, UN FEU CAUSANT LA MORT OU DES
DOMMAGES SÉRIEUX PEUT SE PRODUIRE.
IMPORTANT POUR VOTRE SÛRETÉ
LISEZ ET SUIVEZ TOUS LES AVERTISSEMENTS ÉQUIPÉS DE VOTRE CYLINDRE DE GAZ DE PROPANE.
En actionnant cet appareil avec un cylindre de gaz de propane ON DOIT observer ces instructions et avertissements.
LE MANQUE DE FAIRE AINSI PEUT AVOIR COMME CONSÉQUENCE UNE INCENDIE OU UNE EXPLOSION SÉRIEUSE.
CYLINDRE ET CONDITIONS ET
CARACTÉRISTIQUES DE CONNECTEUR
a. Les bouteilles, les vannes et les tuyaux de propane doivent
être entretenus et inspectés avant chaque utilisation. Ils
doivent être remplacés en cas de dommages visibles. Si
le tuyau est coupé ou présente des signes d’abrasion ou
d’usure, il doit être remplacé avant utilisation (voir e.).
b. Cette unité, lorsqu'elle est utilisée avec une bouteille, doit
être connectée à une bouteille standard de gaz propane de
5 gallons (20 lb) équipée d'un dispositif anti-débordement
répertorié. L’appareil est obligatoire sur toutes les bouteilles
vendues depuis le 1er octobre 1998 afin d’empêcher tout
remplissage excessif.
c. Les dimensions du cylindre doivent être d'environ 12 "(30,5 cm)
de diamètre et 18" (45,7 cm) de hauteur. Les bouteilles doivent
être construites et marquées conformément aux spécifications
du ministère des Transports (DOT) pour les bouteilles à gaz LP
ou à la norme relative aux bouteilles, sphères et tubes pour le
transport des marchandises dangereuses et à la Commission,
CAN / CSA-B339, selon le cas.
d. Le cylindre doit inclure un collier pour protéger la valve
de cylindre et le circuit d’alimentation de cylindre doit être
assuré le retrait de vapeur.
e. Le montage du régulateur de pression et le flexible (Fig. 6-1)
fourni avec cet appareil au gaz en plein air (modèles au
propane seulement) doit être utilisé. Assemblées d'origine et
régulateur de pression et le tuyau de remplacement doivent
être ceux spécifiés par le fabricant pour le raccordement d'un
dispositif de cylindre de liaison identifiée comme de type I
par le ANSI Z 21.58/CGA 1.6 (voir liste des pièces pour les
informations de commande).
f. La valve de cylindre de gaz de propane doit être équipée
d’un dispositif d’accouplement de raccordement de
cylindre, décrit comme type I dans la norme définie dans le
e. de paragraphe ci-dessus. Ce dispositif est généralement
décrit comme coupleur de fil de point culminant.
g. Si votre cylindre de gaz de propane vient avec une prise
de la poussière, placez le bouchon anti-poussière sur la
sortie de valve de cylindre toutes les fois que le cylindre
n’est pas en service.
OPÉRATION DE COUPLEUR
Pour relier le regulator/hose à l’ajustage de précision de
valve de cylindre de gaz de propane: Serrez l’écrou de main
sur le régulateur au-dessus de l’ajustage de précision de fil
de point culminant sur la valve de cylindre. Tournez l’écrou de
1
2
3
4
e. Le régulateur de pression et l’ensemble de tuyau utilisé
doivent assortir les spécifications pour le type I par ANSI
Z 21.58/CGA 1.6 (voir la figue. 6-1).
UTILISATION SÛRE ET ENTRETIEN DES CYLINDRES DE GAZ DE PROPANE
7
U
L
Fig. 7-1 Type I Acme thread coupler
Pressure
relief
valve
QCC
Type 1
valve
Brass Acme
thread fitting
Liquid level
indicator
(optional)
Hand nut with Acme
thread
Regulator
Vent
Hose
Hand wheel
The use of pliers or a wrench should not be necessary. Only
cylinders marked “propane” may be used.
To disconnect: Turn the hand nut counterclockwise until
detached (Fig. 7-1).
Important: Before using the unit, and after each time
the cylinder is removed and reattached,
check the hose for wear (see a.) and check
all connections for leaks. Turn off the unit
valves and open the main cylinder valve,
then check connections with soapy water.
Repair any leaks before lighting the unit.
CAUTION: Always turn the propane cylinder main valve
off after each use, and before moving the unit
and cylinder or disconnecting the coupling.
This valve must remain closed and the
cylinder disconnected while the appliance
is not in use, even though the gas flow is
stopped by a safety feature when the coupler
is disconnected.
Carefully inspect the hose assembly each time before the
gas is turned on. A cracked or frayed hose must be replaced
immediately.
If the appliance is stored indoors, the cylinder must be
disconnected and removed. Disconnected cylinders must be
stored outdoors, out of the reach of children, with threaded
valve plugs tightly installed, and must not be stored in a
building, garage, or any other enclosed area.
FOR YOUR SAFETY
a. DO NOT store a spare propane-gas cylinder under or
near this appliance.
b. NEVER fill the cylinder beyond 80-percent full.
c. IF THE INFORMATION IN a. AND b. IS NOT FOLLOWED
EXACTLY, A FIRE CAUSING DEATH OR SERIOUS
INJURY MAY OCCUR.
IMPORTANT FOR YOUR SAFETY
READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE-GAS CYLINDER.
When operating this appliance with a propane-gas cylinder, these instructions and warnings MUST be observed.
FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION.
CYLINDER/CONNECTOR REQUIREMENTS
a. Propane-gas cylinders, valves, and hoses must be
maintained in good condition and inspected before each use
of appliance. They must be replaced if there is any visible
damage. If hose is cut or shows excessive abrasion or wear,
it must be replaced before using appliance (see e.).
b. This unit, when used with a cylinder, should be connected
to a standard 5-gallon (20 lb.) propane-gas cylinder
equipped with a listed overfilling prevention device. The
device has been required on all cylinders sold since
October 1,1998, to prevent overfilling.
c. Cylinder dimensions should be approximately 12" (30.5
cm) in diameter and 18" (45.7 cm) high. Cylinders must
be constructed and marked in accordance with the U.S.
Department of Transportation (D.O.T.) Specifications for
LP-Gas Cylinders, or the Standard for Cylinders, Spheres,
and Tubes for Transportation of Dangerous Goods and
Commission, CAN/CSA-B339, as applicable.
d. The cylinder used must include a collar to protect the
cylinder valve, and the cylinder supply system must be
arranged for vapor withdrawal.
e. The pressure regulator and hose assembly (Fig. 7-1)
supplied with this outdoor gas appliance (L.P. models
only) must be used. Original and replacement pressure
regulator and hose assemblies must be those specified by
the manufacturer for connection with a cylinder connecting
device identified as Type I by the ANSI Z 21.58/CGA 1.6
(see PARTS LIST for ordering information).
f. The propane-gas cylinder valve must be equipped with
a cylinder connection device, described as Type I in the
standard defined in paragraph e. above. This device is
commonly described as an Acme thread coupler.
g. If the propane-gas cylinder comes with a dust plug, place
the dust cap on the cylinder valve outlet whenever the
cylinder is not in use.
COUPLER OPERATION
To connect the regulator/hose assembly to the propane-
gas cylinder valve fitting: Press the hand nut on the regulator
over the Acme thread fitting on the cylinder valve. Turn the hand
nut clockwise to engage the threads and tighten until snug.
e. The pressure regulator and hose assembly used must
match the specification for Type I by ANSI Z 21.58/CGA
1.6 (see Fig. 7-1).
SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS
8
Installation must be performed by a qualified professional
service technician.
This unit is designed for outdoor use only. DO NOT use this
unit inside a building, garage, or enclosed area. DO NOT use
this unit in or on a recreational vehicle or boat.
OVERHEAD CONSTRUCTION AND EXHAUST
HOOD REQUIREMENTS
A minimum 5 foot clearance is required between the cooking
surface and the overhead construction.
When installed under combustible overhead construction,
the area above the cooking surface of the unit must be
covered with an exhaust hood. The exhaust hood provides
the protection for the combustible overhead construction.
See exhaust hood information below and Fig. 8-1.
Important: DO NOT use this appliance under unprotected
combustible overhead construction.
When installed under overhead non-combustible construction,
an exhaust hood is highly recommended; see exhaust hood
information below and Fig. 8-1.
Exhaust Hood
When using an exhaust hood, the area above the cooking
surface of the grill must be covered with a hood larger than
the cooking area of the grill, and with a minimum of 1200
CFM (cubic feet per minute) rated exhaust fan for proper
outdoor application.
INSTALLATION REQUIREMENTS
Fig. 8-1 Overhead requirements
Min.
5'
OVERHEAD CONSTRUCTION
EXHAUST
HOOD
Combustible overhead
construction:
Exhaust hood required
Non-combustible
overhead construction:
Exhaust hood highly recommended
N
O
N
C
O
M
B
U
S
T
I
B
L
E
W
A
L
L
Fig. 8-1 Overhead requirements
Min.
5'
OVERHEAD CONSTRUCTION
EXHAUST
HOOD
Combustible overhead
construction:
Exhaust hood required
Non-combustible
overhead construction:
Exhaust hood highly recommended
N
O
N
C
O
M
B
U
S
T
I
B
L
E
W
A
L
L
9
REAR WALL CLEARANCES
For the minimum clearances between the unit and rear walls,
your setup must fall within one (or more) of the following:
A. Clearance between unit and strictly non-combustible
rear wall
(i.e. brick wall, see Fig. 9-1)
The unit must have a minimum clearance of 4" from
the non-combustible rear wall.
(To allow for proper ventilation and prevent dangerous
overheating.)
B. Clearance between unit and a protected combustible
rear wall
(i.e. a non-combustible wall in front of a combustible wall
to serve as a barrier. This can be accomplished by brick,
or a metal stud finished with non-combustible substrate,
see Fig. 9-2)
The unit must have a minimum clearance of 14" from
the protected combustible rear wall.
(The 4" non-combustible material plus an additional 10"
clearance between the unit and protected rear wall.)
C. Clearance between unit and combustible rear wall
The unit must have a minimum clearance of 18" from
the combustible rear wall (see Fig. 9-3).
SIDE WALL / CORNER WALL CLEARANCES
(if applicable)
The unit must have a minimum clearance of 24" from any
side walls (to account for variables in airflow that could affect
performance). See Fig. 9-4.
INSTALLATION REQUIREMENTS (Cont.)
Fig. 9-3 Clearance 'B' Diagram
Combustible
Min.
18"
(Clearance required for
rear wall)
Fig. 9-1 Clearance 'A' Diagram
Non-combustible
Min.
4"
(Clearance required for
rear wall)
Fig. 9-2 Clearance 'B' Diagram
Min.
14"
Non-combustible
substrate
Non-combustible 4"
Com-
bustible
(Clearance required for
rear wall)
Fig. 9-4 Side/corner wall clearance
Min.
24"
10
The control panel MUST remain removable for servicing (see
CONTROL PANEL REMOVAL section).
COMBUSTION AIR AND COOLING AIRFLOW
Proper airflow (front-to-back, Fig. 10-1) MUST be maintained
for the unit to perform as it was designed. If airflow is blocked,
overheating and poor combustion will result. Do not block the
1" front air inlet along the bottom of the control panel.
CAUTION: Wind blowing into or across the rear oven lid
vent (Fig. 10-3) can cause poor performance
and/or dangerous overheating. Install the grill
so that the prevailing wind blows toward the
front of the grill (Fig. 10-2). A wind deflector is
included (pre-installed) to assist in proper
airflow during windy conditions.
GAS-SUPPLY PLUMBING REQUIREMENTS
For natural gas or a household propane system, rigid
1
/
2
" or
3
/
4
" black steel pipe or local code-approved pipe is required
to conduct the gas supply to the unit. Contact your local gas
supplier. Connect this pipe to the C.S.A.-approved quick
connect hose (attached). Apply only joint compounds that are
resistant to all gasses on all NPT pipe fittings except flare
fittings. Make sure to tighten all fittings securely.
Note: If
1
/
2
" pipe is used with natural gas, it should be
no longer than 20'.
Important: A shut-off valve (not included) in the gas
line is required. It provides for safety when
the unit is not in use and for convenient
maintenance and repair. It must be installed
within 6 feet of the unit. Use a pipe joint
compound resistant to all gasses on all male
fittings except flare fittings.
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" water column (w.c.), minimum
5", maximum 10
1
/
2
". For propane gas - normal 11" w.c.,
minimum 10", maximum 13".
INSTALLATION REQUIREMENTS (Cont.)
CORRECT
PLACE GRILL SO PREVAILING
WIND BLOWS TOWARD FRONT
OF GRILL
Fig. 10-2 Airflow direction - CORRECT
(1" front air inlet)
Fig. 10-1 Airflow diagram
YOU MUST PROTECT
REAR OVEN VENT FROM
PREVAILING WIND
Rear oven lid vent
INCORRECT
Fig. 10-3 Airflow direction - INCORRECT
CORRECT
PLACE GRILL SO PREVAILING
WIND BLOWS TOWARD FRONT
OF GRILL
Fig. 10-2 Airflow direction - CORRECT
YOU MUST PROTECT
REAR OVEN VENT FROM
PREVAILING WIND
Rear oven lid vent
INCORRECT
Fig. 10-3 Airflow direction - INCORRECT
11
Model
Height Width Depth
Floor to top
(with oven)
Floor to top
of shelf
(C)
Left to right Front to back
Post base
(D)
Shelves
(E)
Post base
(F)
Maximum
outer
(G)
Open (A) Closed (B)
CM430s
57
1
/8" 49
7
/8" 36" 26" 51
1
/4" 20
1
/4" 25
1
/4"
CMA430s
52
1
/8" 44
7
/8" 31" 26" 51
1
/4" 20
1
/4" 25
1
/4"
Fig. 11-1
G
C
F
E
D
A
B
Table 2 - Post Patio Mount Grill Dimensions
CM(A)430s
Main burner quantity
N/P orifice drill size
2
#41 / #54
Table 1 - Product Specifications
MODEL SPECIFICATIONS
(CM430s shown)
This manual is for all CM (Choice Multi-user) and CMA (Choice Multi-user Accessible) models.
CM models are primarily depicted. Any differences are noted.
12
Ground level
L
K
N
O
J
M
H
I
Model
Height* Width Depth
Floor to top
(with oven)
Floor to
top of
shelf
(J)
Floor to
bottom of
extension
below
ground
(K)
Left to right Front to back
Post
(L)
Shelves
(M)
Post
(N)
Maximum
outer
(O)
Open
(H)
Closed
(I)
CM430s
57
1
/8" 49
7
/8" 36” 18” 5
1
/2 51
1
/4" 5
1
/2 25
1
/4"
CMA430s
52
1
/8" 44
7
/8" 31” 18” 5
1
/2 51
1
/4" 5
1
/2 25
1
/4"
*Note: Height dimensions are approximate from ground level once installed.
Table 3 - In-Ground Post Grill Dimensions
MODEL SPECIFICATIONS (cont.)
Fig. 12-1
(CM430s shown)
13
16
1
2
4
10
9
IMPORTANT
Remove all packing
material and discard prior
to lighting.
12
To order replacement
parts, contact your
local Fire Magic
®
dealer.
5
16
15
14
7
17
6
3
22
18
19
23
8
11
REPLACEMENT PARTS LIST - CM GRILLS
14
CM430s
Item Description Part No. Qty.
1.
Stainless cooking grid (set of 2) 3542-DS-2 1
2.
Flavor grid (set of 2) 3063-S-2 1
3.
Main burner 3042-60 2
4.
Oven hood 23729-58 1
5.
Warming rack 3672S-B 1
6.
Patio mount post base w/ hardware * 24330-31 1
or
In-ground post base w/ hardware * 24330-32 1
7.
Patio mount hardware kit (if applicable) 24330-25 1
8.
Convertible regulator PR-4 1
9.
Valve manifold 24131-10 1
10.
Control panel assembly 24131-02 1
11.
Cooking grid locking channel 24131-03 1
12.
Control knob w/ locking screw 3026CM 2
13.
Oven lid thermometer w/ bezel
23307 1
14.
Drip tray 3093 1
15.
Drip tray liner (set of 4) 3557 1
16.
Rigid shelf 24330-018 2
17.
Timer valve (1 hour) 3092B 1
18.
Main burner igniter assy only 3199-50 1
19.
Main burner valve with igniter assy 3025 2
20.
Natural gas orifice(s)
3001-41-2 1
21.
Propane gas orifice(s)
3001-54-2 1
22.
Air baffle 24194-40 1
23.
Wind deflector 23729-19 1
* For replacement only (not conversion)
Not shown
REPLACEMENT PARTS LIST - CM GRILLS (Cont.)
15
19
1
2
4
12
11
IMPORTANT
Remove all packing
material and discard prior
to lighting.
14
To order replacement
parts, contact your
local Fire Magic
®
dealer.
7
19
18
17
9
20
8
3
25
21
22
26
10
13
REPLACEMENT PARTS LIST - CMA GRILLS
5
15
16
CMA430s
Item Description Part No. Qty.
1.
Stainless cooking grid (set of 2) 3542-DS-2 1
2.
Flavor grid (set of 2) 3063-S-2 1
3.
Main burner 3042-60 2
4.
Oven hood 23729-58 1
5.
Oven hood side handle kit 3600-50 1
6.
Oven hood spring kit * 23729-71 1
7.
Warming rack 3672S-B 1
8.
Patio mount post base w/ hardware
24330-31CMA 1
or
In-ground post base w/ hardware
24330-32CMA 1
9.
Patio mount hardware kit (if applicable) 24330-25 1
10.
Convertible regulator PR-4 1
11.
Valve manifold 24131-10 1
12.
Control panel assembly 24131-02 1
13.
Cooking grid locking channel 24131-03 1
14.
Control knob w/ locking screw 3026CMA 2
15.
Control knob bezel 3000-66 2
16.
Oven lid thermometer w/ bezel * 23307 1
17.
Drip tray 3093 1
18.
Drip tray liner (set of 4) 3557 1
19.
Rigid shelf 24330-018 2
20.
Timer valve (1 hour) 3092B 1
21.
Main burner igniter assy only 3199-50 1
22.
Main burner valve with igniter assy 3025 2
23.
Natural gas orifice(s) * 3001-41-2 1
24.
Propane gas orifice(s) * 3001-54-2 1
25.
Air baffle 24194-40 1
26.
Wind deflector 23729-19 1
* Not shown
† For replacement only (not conversion)
REPLACEMENT PARTS LIST - CMA GRILLS (Cont.)
17
Fig. 17-3 Post base option
INSTALLATION
DO NOT lift the unit from the control panel when installing.
PREPARE FOR INSTALLATION
Consult a qualified professional installer.
The flex connector can be routed out the back of the post,
under the post base, or inside the post.
To gain access to the inside of the post, unscrew and carefully
open the access plate on the rear of the post using a medium
Phillips-head screwdriver. Retain the screws.
ROUTE FLEX CONNECTOR
The gas supply line will need to be run to the post install
location as appropriate for the desired setup.
To route flex connector through rear of post:
1. Remove a knock-out disk at the bottom of the access plate
with a large flathead screwdriver. (Insert the screwdriver
into the notch provided in the center of the knock-out.)
2. Remove the plastic grommet (attached to the flex
connector) and insert it into the newly created opening.
Then route the flex connector through the opening. See
Fig. 17-1 and 17-2.
To route flex connector beneath post base:
Route the flex connector through the hole found beneath the
center of the post base (see Fig. 17-3).
Fig. 17-1 Access plate view & install orientation
Access
plate
Fig. 17-2 Post interior detail
Gas supply knock-out
(grommet installed)
Flex connector
(w/ flare-to-NPT
adapter)
Back of
timer valve
Flex
connector
(w/ flare-
to-NPT
adapter)
(Design
may vary)
PATIO MOUNT INSTALLATION
18
CONNECT THE GAS SUPPLY
For household propane or natural gas units:
1. Route the flex connector to the gas supply stub.
2. Turn OFF the gas supply at the source.
3. A shut-off valve is required within 6 feet of the unit.
If shut-off valve is installed in-line:
Install the supplied flare-to-NPT adapter to the gas
supply (NPT) using a pipe joint compound resistant to
all gasses (see Fig. 18-2, A). Tighten securely.
Connect the flex connector to the adapter (see Fig.
18-2, A). Tighten securely.
If shut-off valve is connected to end of gas supply stub:
Connect the flex connector to the shut-off valve (flare)
(see Fig. 18-2, B). Tighten securely.
For propane cylinders:
For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE GAS
CYLINDERS.
Important: An appropriate adapter will be required to connect
the existing flex connector to an L.P. regulator/
hose assembly.
LEAK TEST
Turn all burner control knobs to the OFF position. Turn the gas
supply on. Then carefully check all gas connections for leaks
with a brush and half-soap/half-water solution before lighting.
NEVER USE A MATCH OR OPEN FLAME TO TEST FOR
LEAKS.
RE-SECURE ACCESS PLATE
Carefully replace the access plate using the four screws,
ensuring all interior components are properly oriented inside
of the grill. Ensure the flex connector coming out of the rear of
the post is properly situated and the plastic bushing/grommet
pieces are secure in place (if applicable).
SECURING THE PATIO MOUNT GRILL
Important: BEFORE USE, the patio mount base must be
securely fastened to a stable, level surface to
ensure the grill remains fixed and upright at all
times.
Locate the patio mount base in the planned grill location and
mark the 4 holes. Drill the marked holes to a
1
/
2
" diameter x
1
1
/
2
" depth. Insert the lag shields (see PARTS LIST) into the
holes, being sure that they are flush with the ground.
Align the holes on the patio mount base over the lag shields in
the ground. Secure the base with the lag screws (see PARTS
LIST) using a
7
/
16
" nut driver.
Fig. 18-1 Connect gas and secure plate
Flare-
to-NPT
adapter
Flex
connector
To gas supply
(as applicable,
flex location
may vary)
Fig. 18-2 Connecting to a gas line
Gas supply
(NPT)
Flex
connector
(from grill)
Flare-to-NPT
shut-off
valve*
(end of gas
supply)
NPT-to-NPT
shut-off
valve*
(in-line)
Gas supply
(NPT)
Flare-to-NPT
adapter
Flex
connector
(from grill)
* Shut-off valve: required, not included, must
be within 6 feet of unit
A B
-OR-
PATIO MOUNT INSTALLATION (cont.)
19
DO NOT lift the unit from the control panel when installing.
PREPARE FOR INSTALLATION
Consult a qualified professional installer / licensed contractor.
The in-ground post is designed primarily for installation with a
permanent underground gas supply.
To gain access to the inside of the post, unscrew and carefully open
the access plate on the rear of the post using a medium Phillips-
head screwdriver. Retain the screws.
ROUTE GAS SUPPLY (UNDERGROUND METHOD)
Note: This section addresses an underground gas supply setup.
To connect through the rear of the post, reference the
ROUTE FLEX CONNECTOR section of PATIO-MOUNT
INSTALLATION, and do not perform the steps until after:
attaching the extension post, and installing the post / pouring
the concrete.
1. After running the underground gas supply (NPT) line to the
planned grill location, dig a hole for the post and extension
approximately 18" deep and 10-12" in diameter.
Note: Run the gas supply line up from the bottom of the hole
(a little off center) so that it reaches to approximately 4"
above ground level.
Note: CM models: The actual depth of the hole should be such
that the shelf surface is approximately 37" above ground
level.
CMA models: The actual depth of the hole should be
such that the shelf surface is approximately 32" above
ground level.
2. Verify that the gas supply line fits through the gas line clearance
hole in the bottom of the post (see Fig. 19-
2). The clearance hole is
the larger of the two holes in the bottom of the post and is off center.
3. Verify that the flex connector coming from the inside of the
post will connect properly with the gas supply line.
Fig. 19-1 In-ground install orientation
Ground level
Concrete level
Post
Gas supply (NPT)
route
4" (approx.)
18"
(approx.)
3-5"
Flex connector
(w/ flare-to-NPT adapter)
Fig. 19-2 Post interior detail
Flex connector
(w/ flare-to-NPT
adapter)
Back of timer
valve
(Design
may vary)
Gas supply
line (NPT)
IN-GROUND POST INSTALLATION
20
ATTACH POST EXTENSION
1. Attach the extension to the bottom of the grill post so
that the open portion is toward the back of the grill and
the five holes in the extension line up with the five (5)
weld-nuts in the post (see Fig. 20-1).
2. From outside the joined post and extension, insert
one of the
1
/
4
X 20"-
5
/
8
bolts (supplied) into each of
the five (5) bolt holes and tighten each using a
7
/
16
"
socket driver or wrench (see Fig. 20-2).
Note: There is one hole on each side of the post,
except the back which has two holes located on
either side of the extension opening.
PLACE POST IN-GROUND & POUR
CONCRETE
1. Prepare the concrete to be used for the install.
2. Carefully orient the post over the gas supply line and
into the installation hole.
Important: Verify that the gas supply line is running up
through the post hole, just off center. It must
extend high enough to reach the grill gas
connection and remain safely above the level
of the concrete when poured.
3. Remove the post, then cover the end of the gas supply
line with a plastic bag and/or masking tape to avoid
getting concrete or other debris in the supply line.
4. Pour the concrete into the hole 3-5" below ground
level taking care to protect the gas supply line.
5. While the concrete is still wet, carefully lower the
extended grill post into the hole so that the gas
supply line slides through the clearance hole in the
bottom of the post.
6. Orient the grill per plan, then level the grill and support
it so that it remains in position while the concrete drys.
ROUTE FLEX CONNECTOR (ABOVE GROUND
METHOD ONLY)
Note: This section addresses an above ground gas
supply setup. If connecting underground, skip this
section and continue with installation.
The gas supply (NPT) line will need to be run to the post
install location as appropriate for the desired setup.
To route flex connector through rear of post:
1. Remove the knock-out disk at the bottom of the access
plate with a large flathead screwdriver. (Insert the
screwdriver into the notch provided in the center of
the knock-out.)
2. Remove the plastic grommet (attached to the flex
connector) and insert it into the newly created opening.
Then route the flex connector through the opening.
See Fig. 20-4.
Bolts
Weld-nut
To grill
Post
Extension
(position
open side
toward back)
Install
provided bolts
into 5 holes
around post
Fig. 20-1 Install extension to post
Fig. 20-2 Fasten extension to post
Ground level
Concrete level
Post
Gas supply (NPT)
route
Fig. 20-3 Pour concrete & install post
3-5"
Gas supply line (NPT)
(cover to protect)
Fig. 20-4 Access plate view & install orientation
Access
plate
Gas supply knock-out
(grommet installed)
Flex connector
(w/ flare-to-NPT
adapter)
Flex connector
(w/ flare-to-NPT adapter)
(Design
may vary)
IN-GROUND POST INSTALLATION (cont.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Fire Magic Choice Multi-User and Accessible Post Grills Manuel utilisateur

Catégorie
Barbecues
Taper
Manuel utilisateur