CREE LIGHTING KBL-C Wireless Guide d'installation

Taper
Guide d'installation
KBL-C Series
WIRELESS LED Luminaire
Universal Hook and Cord or Pendant Mount with Sensor
1 of 6 LPN00881X0002A0_B
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always
be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant
l’installation.
2. This luminaire must be installed in accordance with the NEC or your
local electrical code. If you are not familiar with these codes and
requirements, consult a qualied electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n’êtes pas familier avec ces codes et ces
exigences, veuillez contacter un électricien qualié.
3. Suitable for damp location.
Convient aux emplacements humides.
4. Maximum ambient operating temperature: 9L, 12L, 18L = 50°C and
24L, 30L, and 35L= 40°C.
Température ambiante maximale de fonctionnement:
9L, 12L, 18L = 50°C et 24L, 30L, et 35L= 40°C.
5. MIN 90°C SUPPLY CONDUCTORS
LES FILS D’ALIMENTATION 90°C MIN.
6. This equipment should be installed and operated with a minimum
distance 20cm between the radiator and your body.
L’équipement doit etre installe d’une facon qu’une distance minimum
de 20cm soit maintenue entre l’emetteur et toute partie du corps.
7. Check to make sure that all input power connections have been
properly made and the module is grounded to avoid potential
electrical shock.
8. DO NOT lift luminaire by the power cord or any of the cables
connected to the LED heatsink and LED driver.
9. All electrical connections for the sensor have been made at the
factory.
10. The sensor is designed for mounting heights between 8 ft. to 40 ft.
(2.4 m to 12.2 m).
11. When mounting heights are above 30ft. (9.1 m), the sensor
generally only detects large objects such as forklift trucks.
12. When the sensor lens assembly is removed the exposed sensor
body is sensitive to electrostatic discharge. Take the necessary
steps to avoid possible damage to the sensor.
13. Use Class 1 Wiring methods ONLY
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
TO INSTALL:
HOOK AND CORD MOUNT
STEP 1:
Push down on retainer spring until top of spring is free of luminaire
hook. See Figure 1.
STEP 2:
Slide hook into securely mounted customer supplied eye hanger
and return retainer spring to original position.
NOTE: The luminaire should already be factory set for correct
balance. If necessary, the fixture may be balanced by loosening the
hook adjustment screws on the top of the housing and sliding the
hook as necessary for correct balance. Tighten hook adjustment
screws when finished. See Figure 1.
STEP 3:
Make wiring connections per the Electrical Connections section.
After electrical connections for luminaires with a sensor go to
pages 4-6 for installation of sensor.
NOTES:
For each mounting application below, when mounting to surface
ensure that the mounting surface and customer supplied hardware is
capable of supporting the weight of the luminaire.
The center of mounting is NOT the same as the center of luminaire.
Images used in this installation sheet are for illustration purpose,
there are dierent congurations of the luminaire.
1
Luminaire Hook
Hook Adjustment Screws
Retainer Spring
1/2” (13mm) IP, 0.875”
(22mm) O.D. Knockout
KBL WIRELESS WITH
UL NETWORK SENSOR
KBL WIRELESS
WITH UH NETWORK
SENSOR
KBL
WIRELESS
2 of 6 LPN00881X0002A0_B
PENDANT MOUNT
STEP 1:
Remove hinged splice box from top of housing
by loosening screw and sliding box to the right
and up from “L” channel. Unhook from hinge
holes. See Figure 2.
STEP 2:
Remove hook, slider plate and cord and
discard. Plug junction box knockout hole with
provided junction box plug.
STEP 3:
Attach the supplied pendant mount slider plate
using (2) supplied screws. Use 3/4” threaded
pendant, along with two customer supplied
locknuts (one for inside the hinged splice box
and one for outside the splice box). Pull supply
leads into position from customer supplied
conduit.
Note: If necessary, the luminaire may be
balanced by loosening (2) screws for pendant
adjustment on the top of the hinged splice box
and sliding the adjustment plate as necessary
for correct balance. Tighten (2) screws when
finished. See Figure 2.
STEP 4:
Attach one end of the hinged splice box to
luminaire by aligning hinge slots on Mounting
Bracket with hinges (on splice box), and then
inserting the hinges into the slots.
STEP 5:
Make wire connections per Electrical
Connections and then push the leads into
hinged splice box. Close the hinged J-box and
re-tighten the screw. See Figure 3.
STEP 6:
Secure other end of the hinged splice box
to luminaire by sliding screw on Mounting
Bracket up and over in “L” channel on the
hinged splice box. See Figure 2.
STEP 7:
Secure luminaire to hinged splice box by
tightening screw. For luminaires with a sensor
go to pages 4-6 for installation of sensor.
REFLECTOR INSTALLATION
TOOL LESS REFLECTOR:
STEP 1:
Place the reflector tabs between the luminaire
mounting tabs. See Figure 4.
Step 2:
Turn the reflector clockwise until it locks into
place under the locking tab. See Figure 4.
NOTE: For additional reflector security
#6 x 5/16” self tapping screws can be added
to the screw holes in the mounting tabs. See
Figure 4.
Step 3:
To remove the reflector, lift the locking tab and
turn the reflector counter-clockwise.
2
“L” Channel
Pendant Mount Hole
3/4” (19mm) IP, 1.125”
(29mm) O.D.
1/2” (13mm) IP,
0.875” (22mm)
O.D. Knockouts
3/4” (19mm) IP,
1.125” (29mm)
O.D. Knockouts
Adjustment Screws
Hinged Splice
Box
Pendant Slider
Plate
Hinged J-box
3
Hinged J-box
Screw
Luminaire Mounting
Tabs
Luminaire Mounting
Tabs
Screw
Holes
Locking
Tab
4
3 of 6 LPN00881X0002A0_B
Mounting Ring
Reflector
Lens with V-band
Screw
7
STANDARD REFLECTOR:
STEP 1:
Loosen the (4) screws, shown in Figure 5, at
least 0.1 inch from the heatsink.
NOTE: The view in Figure 5 is of the underside
of the luminaire.
Mounting Lens or Wire Guard To
Aluminum Reflector
STEP 1:
Secure the hinge retainer and frame hinge to
the reflector using supplied screw and lock
nut. See Figure 6.
NOTE: Reflector is pre-punched at position of
this installation.
STEP 2:
Swing the wire guard into place and secure to
the reflector with the attached spring latch.
See Figure 6.
Mounting Lens or Wire Guard To
Prismatic Reflector
STEP 1:
Place lens or wire guard onto the bottom of
reflector, and place V-band around lens and
reflector. See Figure 7.
STEP 2:
Secure lens or wire guard to reflector by
tightening screw on V-band. (See Figure 7) or
installing spring on V-band (See Figure 8).
SITE MAP LABEL
STEP 1:
Remove unit site map label SNAP address.
See Figure 9.
STEP 2:
Apply site map label to the correct position on
the site map. See
Figure 9.
INSTALLING SAFETY CABLE
NOTE: Safety Cable is sold separately as an
accessory, please refer to installation sheet in
safety cable packaging for complete installing
instructions.
STEP 1:
Attach one end of the safety cable through the
hole on the lower housing (either side). See
Figure 10.
STEP 2:
Attach other end of the safety cable to
mounting surfaces using customer supplied
hardware.
SYSTEM COMMISSIONING AND
CUSTOMIZING
System commissioning is required for the
fixtures to be recognized on the Simply SNAP
network. Contact Cree Lighting at 800-236-
6800 for more details about commissioning
and customizing.
6
Reflector Hinge Retainer
Frame Hinge
9
Site Map
Label
Reflector
Lens with V-band
Spring
8
5Loosen
Screws
Safety Cable
10
4 of 6 LPN00881X0002A0_B
ELECTRICAL CONNECTIONS
STEP 1:
NOTE: USE MIN. 90°C SUPPLY CONDUCTORS for 120-480V luminaires.
Make the following Electrical Connections:
a. For 120/277/347V connect the black fixture lead to the voltage
supply or Hot 1 (for 208/240/480V wiring).
b. For 120/277/347V connect the white fixture lead to the neutral
supply or Hot 2 (for 208/240/480V wiring).
c. Connect the green or green/yellow ground lead to the green wire
position of the terminal block.
STEP 2:
The Blue/White low-voltage wires are used to override the luminaire to
full output. They may be connected to third-party equipment to provide an
override signal to the luminaire. Do not connect the Blue/White wires to a
voltage supply. The wires should be capped if not being used.
SHORT: Luminaire overrides to full output
OPEN: Luminaire operates normally
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
NEUTRAL
OR HOT 2
SUPPLY WIRING
LUMINAIRE
BLUE W/WHITE
BLUE W/WHITE
Wire Form
11
SENSOR INFORMATION
For programming of sensor and more detailed description
of sensor visit https://legrand.us/lighting-controls-and-
systems/occupancy-and-vacancy-sensors/in-fixture-
sensors/line-low-voltage-0-10v-pir-fix-sens-120-277vac-
no-ir-conf/p/fsp-202.
The FSP-202 sensor has been preset with the optimal
settings to provide the widest range of user flexibility
and performance of the Synapse Environment. Sensor
characteristics can be modified in the Synapse user
interface.
NOTE: Ensure that you remove the label on the unit that
says, “Remove This Label Before Installing Lens. If this
label is not removed, the sensor will not work properly.
INSTALLING UL (120V-277V)SENSOR
STEP 1:
Rotate the wire form up as shown. The wire form will snap
into position to hold the Sensor horizontal. See Figure 11.
STEP 2:
Locate the wire form on the sensor and install onto the
luminaire by inserting the wire form into the (2) tabs under
the driver box. See Figure 12 on the next page.
5 of 6 LPN00881X0002A0_B
Driver Box
Wire
Form
Tabs
12
Sensor Adjustment
Screw
INSTALLING UH (347V-480V) SENSOR
STEP 1:
Rotate the wire form up as shown. The wire form will snap into position
to hold the Sensor horizontal. Confirm that Sensor screw is tight. See
Figure 13.
STEP 2:
Locate the wire form on the sensor and install onto the luminaire
by inserting the wire form into the (2) tabs under the driver box. See
Figure 14.
STEP 3:
Rotate Sensor as needed to level position or adjust field of view.
NOTE: The horizontal position is fixed.
Driver Box
Wire
Form
Tabs
Sensor Adjustment
Screw
14
13
Wire Form
6 of 6 LPN00881X0002A0_B
www.creelighting.com
© 2023 Cree Lighting USA LLC. All rights reserved. For informational purposes only. Content is subject to change. See www.
creelighting.com/warranty for warranty and specifications. Cree® and the Cree Lighting logo are registered trademarks of
SMART Global Holdings, Inc. NEMA® is a registered trademark of the National Electrical Manufacturers Association. The
Synapse® is a registered trademark of Synapse Wireless, Inc.
TECHNICAL SUPPORT
If unable to successfully resolve problems with the sensor, call 800-236-
6800 for Cree Lighting technical support.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE
STATEMENT
CAUTION: Changes or modifications not expressly approved could void
your authority to use this equipment.
This device complies with Part 15 of the FCC Rules. Operation to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The LED in the front of this device operates within Risk Group 1 levels
per IEC 62471.
This device has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the device is operated in a commercial environment.
This device generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this device in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his
own expense.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device. In addition, this device complies with ICES-005 of the
Industry Canada (IC) Regulations.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
The antennas used for this transmitter must be installed to provide
a separation distance of at least 20 cm from all persons and
must not be co-located or operating in conjunction with any other
antenna or transmitter.
15
Torque clamp bolt
¼-1/2 Turn
16
Remove lens to access dials
INSTALLING REMOTE SENSOR
NOTE: Install Clamp onto beam and turn Bolt until it contacts the
beam, torque Beam Clamp Bolt an additional 1/4-1/2 of a turn after
bolt contacts the beam. Insure clamp is secure prior to adjusting
Sensor position. See Figure 15.
The remaining 2 screws can be used to fine tune the position/view
of the Sensor. See Figure 15.
SENSOR DESCRIPTION
The FSP-202 is a motion sensor that controls lighting levels based
on occupancy and ambient light.
The sensor uses passive infrared (PIR) sensing technology that
reacts to changes in infrared energy (moving body heat) within
the coverage area. Once the sensor stops detecting movement
and the time delay elapses, lights will go from high to low mode
and eventually turn off if it is desired. Sensors must directly “see”
motion of a person or moving object to detect them, so careful
consideration must be given to sensor luminaire placement and
lens selection. Avoid placing the sensor where obstructions may
block the sensor’s line of sight.
The FSP-202 is designed for indoor environments. The FSP-202 is
preset from Cree Lighting to optimize functionality and flexibility of
the sensor’s behavior through the Synapse user interface. Factory
settings from Cree Lighting are listed below. See Figure 16.
KBL Wireless FSP-202 Settings:
Mode = C
Dim = 10V
Time = 30s
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

CREE LIGHTING KBL-C Wireless Guide d'installation

Taper
Guide d'installation

dans d''autres langues