TLI Pro 101 • Setup Guide
Overview
The Extron TLI Pro 101 is a TouchLink
®
Interface that works with any Extron IP Link
®
Pro control processor, to allow a third party
touchscreen display to be used as a point of control within an Extron Pro Series control system. The scaled output supports
displays from 800x600 to 1920x1200, as well as HDTV 1080p/60. This guide provides instructions for experienced installers to
mount and install a TLIPro 101 and to create a basic conguration. For more complete instructions, see the TLIPro 101 User
Guide, at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
Global Configurator Professional or Global Configurator Plus — for setting up and conguring the control processor and
touchpanel.
GUI Designer — for designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces.
Both software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you will also require
IP address Subnet mask Gateway
User name — by default these are either admin or user.
Passwords — the factory congured passwords for all accounts on this device have been set to the device serial
number. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password is the default password conguration. The default
password is extron.
Make a note of the interface MAC address.
Mount and Cable All Devices
ATTENTION:
Do not power on the TLI Pro 101 or control processors until you have read the Attention in the Power Supply section
of the TLI Pro 101 User Guide or the IPL Pro User Guide.
Ne branchez pas le TLI Pro 101 ou les contrôleurs avant d’avoir lu la mise en garde dans la section «sources
d’alimentation» du TLI Pro 101 UserGuide ou du IPLProUserGuide.
Mount the units. Stand the TLI Pro 101 on a convenient surface, mount it in a standard rack, or use an under-table mounting
kit (see the TLIPro 101 User Guide, at www.extron.com). To mount the third-party touchpanel follow the instructions
provided by the manufacturer.
Connect cables to the TLI Pro 101.
Connect the HDMI output from the TLI Pro 101 to the third-party touchpanel.
Connect the USB port from the TLI Pro 101 to the third-party touchpanel.
NOTE: The USB connection passes information to the TLI Pro 101 about where on the screen the touchpanel was
pressed. To use a normal monitor, instead of a touchscreen, connect a mouse to the TLI Pro 101 USB connection.
Use the mouse to click on screen icons.
Connect power cords and power on all devices.
Set up the TLI Pro 101 for Network Communication
Connect the PC that you will use for setup, the control processor, and TLI Pro 101 on the same Ethernet subnetwork.
Use the Setup Menu (see page 3) or the Toolbelt feature of Global Congurator Professional or Global Congurator Plus to
set the DHCP status and, if necessary, the IP address, subnet mask, gateway, and related settings for the interface.
www.extron.com
TLI Pro 101 • Setup Guide (Continued)
Configure the Interface
The Global Configurator Professional Help File, the Global Configurator Plus Help File, and the GUI Designer Help File provide
step-by-step instructions and more detailed information. The Global Congurator Professional and Global Congurator Plus help
les include an introduction to the software and sections on how to start a project and conguration.
Rear Panel Connectors and Features
For complete information about the TLI Pro 101 rear panel connectors and features, see the TLI Pro 101 User Guide.
TLI PRO 101
LAN/PoE
USB
HDMIHDMI
+
-
POWER
12 V
RESET
CONTROLOUTPUT
1.0A MAX
INPUT
AB GFECD
Figure 1. TLI Pro 101 Rear Panel
ATTENTION:
The TLI Pro 101 can use a 12 VDC desktop power supply and is also Power over Ethernet (PoE 802.3af, class3)
compliant. Do not connect either power supply before reading the Attention in the Power Supply section of the
TLIPro101 User Guide.
Le TLI Pro 101 peut utiliser une source d’alimentation externe 12 Vcc, et est également compatible avec l’alimentation
POE via Ethernet (PoE 802.3af, classe 3). Ne branchez pas de sources d’alimentation externes avant d’avoir lu les
mises en garde dans la section «PowerSupply» du TLIPro101 User Guide.
A
Power connector — Connect the 2-pole, 3.5 mm captive screw connector from the provided 12 VDC, 1.0 A power supply to
this socket.
NOTE: The TLI Pro 101 also complies with Power over Ethernet standards (PoE 802.3af, class 3).
B
HDMI input — Plug the cable from the input source device into this female HDMI type A connector. Use the provided LockIt
brackets to secure the connector to the TLI Pro 101 unit.
C
HDMI output — Connect this female HDMI type A connector to a third-party touch screen. Use the provided LockIt brackets
to secure the connector to the TLI Pro 101 unit. A full list of compatible resolutions is provided in the TLI Pro 101 User Guide.
D
USB connector — supports High-speed USB 2.0 control. Plug a USB cable from the third-party touchpanel into this female
typeB connector.
NOTE: To use a monitor that is not a touchpanel, connect a mouse to this port.
E
Network and Power over Ethernet connector — Connect the interface to the LAN using a twisted pair cable, terminated
with an RJ-45 connector. The connector can also be used with a PoE power injector (not provided).
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
F
Reset mode LED — indicates power status and reset status of the device.
G
Reset button (recessed) — allows the unit to be reset in any of three different modes. A brief summary of the reset modes is
given below. For more information see the TLI Pro 101 User Guide.
3
Product Category
Front Panel Features
TLI PRO 101
TOUCHLINK INTERFACE
ACT
LINK
100
MENU
ABED
C
Figure 2. TLI Pro 101 Front Panel
A
Power LED — Lights green when the unit is powered on.
B
Menu button (recessed) — opens the setup menu and calibration screen for the interface:
z Press the button briey (less than 2 seconds) to open the internal menu screens.
z Press and hold the button (at least 2 seconds) to open the calibration screen. Follow the on-screen instructions to
calibrate the touchpanel.
z Press the button briey (less than 2 seconds) for a second time to close the current screen without saving any changes.
C
100 Mb network LED — Lights green when the unit is connected to a 100 Mb network.
D
Network link LED — Lights green when the unit is connected to any network.
E
Network activity LED — Blinks amber when there is activity on the network connection.
Reset Modes: a Brief Summary
The TLI Pro 101 offers the following reset modes:
Use factory firmware:
Press and hold the Reset button (Figure 1,
G
) while applying power to the unit. Use this
mode to replace rmware in the event of rmware failure.
Reset All IP Settings:
Press and hold the Reset button for 6 seconds. After the Reset LED (Figure1,
F
) ashes
twice, release and momentarily press the Reset button. Use this mode to reset all network
settings without affecting user-loaded les.
Reset to Factory Defaults: Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times,
release and momentarily press the Reset button. Use this mode to return the interface to
factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set to
the device serial number. Passwords are case sensitive.
If the device is reset to default settings, the password is the default password
conguration. The default password is extron.
Setup Menu
Press the menu button (see Front Panel Features,
B
above) to
open the setup menu. Select any of the six available screens (Status,
Network, Output, Audio, Input, and Advanced) by pressing the
appropriate button in the navigation bar at the top of the screen.
Press the menu button for at least 2 seconds to open the calibration
screen. Follow the on-screen instructions.
Info
Model: TLI Pro 101
Part Number: 60-1083-01
Firmware
Version:
1.00
PoE Status:On
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLI-AB-CD-EF
Output
Resolution:
Project:
Sleep Timer:
800x600
N/A
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Input
HDMI Port: No Signal
Status
Output
Audio
Advanced
Exit
Network
Input
Advanced
Controller IP: N/A
Project Size: N/A
Figure 3. Setup Menu
4
© 2014 - 2020 Extron Electronics All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
68-1817-50 Rev. C
01 20
TLI Pro 101 • Setup Guide (Continued)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Extron TLI Pro 101 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues