INSTALLATION MANUAL
GAS COOKTOP
LSCG366ST
LSCG306ST
LSCG367ST
LSCG307ST
Please read this guide thoroughly before installation.
www.lg.com
MFL62725506_01
ENGLISH
FRANÇAIS
2
INSTALLATION INSTRUCTIONS
INSTALLATION SAFETY INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
Installation of this cooktop must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGAB149.1 or the current
Propane Installation Code, CAN/CGA-B149.2, and
with local codes where applicable. This cooktop
has been design-certified by CSA International
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to
CAN/CGA-1.1 latest edition.
As with any appliance using gas and generating
heat, there are certain safety precautions you
should follow. You will find these precautions in the
lmportant Safety Information section in your User’s
Guide. Read them carefully.
IMPORTANT Save these instructions for
local electrical inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer: Leave these instructions with
the appliance after installation is completed.
Note to Consumer: Keep the User’s Guide and
Installation Instructions for future reference.
NOTE: This appliance must be properly
grounded.
The electrical diagram is in an envelope attached
to the back of the cooktop.
Skill level – Installation of this appliance requires
basic mechanical skills.
Proper installation is the responsibility of
the installer.
Product failure due to improper installation is not
covered under the Warranty.
Remove all tape and packaging.
Make sure the burners are properly seated and
level.
Take the accessory pack off of the cooktop
Check to be sure that no cooktop parts have
come loose during shipping.
3
ENGLISH
IN THE COMMONWEALTH OF MASSACHUSETTS
PREPARING FOR INSTALLATION
FOR YOUR SAFETY
This product must be installed by a licensed
plumber or gas fitter.
When using ball type gas shut-off valves, they shall
be the T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet in length.
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLATION
WARNING:
If the information in
this manual is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
Do not store or use combustible materials,
gasoline or other flammable vapors and
liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches,
• Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor′s phone. Follow the gas supplier
instructions.
If you cannot contact your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
TOOLS YOU WILL NEED
MATERIALS YOU MAY NEED
MATERIALS YOU MAY NEED
• Gas line shut-off valve
To reduce the possibility of gas leaks, apply teflon
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
Flexible metal appliance connector (5/8” I.D.)
A 3-foot length is recommended for ease of
installation but other lengths are acceptable.
Never use an old connector when installing a new
cooktop.
Flare union adapter for connection to gas supply
line (3/4” or 1/2” NPT x 5/8” I.D.)
Flare union adapter for connection to pressure
regulator on cooktop. (1/4” NPT x 1/2” I.D.)
• Liquid leak detector or soapy water.
Phillips screwdriver
Joint
Sealant
Pipe Fittings
Flexible Connector
Shut Off
Valve
Open-end or
adjustable wrench
Pipe wrench(2)
(one for support)
Flat-blade screwdriver
Pencil and ruler
4
IMPORTANT: Remove all packing material and
literature before connecting gas and electrical supply.
• Have your cooktop installed by a qualified installer.
Your cooktop must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes.
Refer to 3. Electrical Connections, in this manual.
Be sure the wall coverings around the cooktop can
withstand heat generated by the cooktop up to
200 °F.
Avoid placing cabinets above the cooktop.
To minimize the hazard caused by reaching over
the open flames of operating burners, install a
ventilation hood over the cooktop that projects
forward at least 5” beyond the front of the cabinets.
INSTALLATION SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill
or hurt you and others. All safety messages will follow the safety alert symbol and either
the word “ WARNING” or “CAUTION”.
BEFORE YOU BEGIN
Remove all tape and packing materials before using the cooktop. Dispose all plastic bags after
unpacking the cooktop. Never allow children to play with packing materials.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions completely and carefully. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified installer, service agency, manufacturer
(dealer) or your gas supplier.
Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and
personal injury. Always use NEW flexible connectors when installing a gas appliance.
This symbol will alert you to hazards or unsafe practices which could
cause serious bodily harm or death.
WARNING
This symbol will alert you to hazards or unsafe practices which could
cause bodily injury or property damage.
CAUTION
5
ENGLISH
INSTALLATION INSTRUCTIONS
The ventilating hood must be constructed of
sheet metal not less than 0.0122” thick. Install
above the cooktop with a clearance of not less
than 1/4” between the hood and the underside of
the combustible material or metal cabinet. The
hood must be at least as wide as the appliance
and centered over the appliance. Clearance
between the cooking surface and the ventilation
hood surface MUST NEVER BE LESS THAN 24
INCHES.
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall
conform to the installation instructions packed with
that appliance.
If cabinets are located above the cooktop, allow
a minimum clearance of 30” between the cooking
surface and the bottom of unprotected cabinets.
If a 30” clearance between cooking surface and
overhead combustible material or metal cabinets
cannot be maintained, protect the underside of
the cabinets above the cooktop with not less than
1/4” insulating millboard covered with sheet metal
not less than 0.0122” thick. Clearance between
the cooking surface and protected cabinets MUST
NEVER BE LESS THAN 24 INCHES.
The vertical distance from the plane of the cooking
surface to the bottom of adjacent overhead
cabinets extending closer than 1” to the plane of
the cooktop sides must not be less than 18”. (See
the Dimensions and Clearances illustration in this
manual.)
Do not abstruct the combustion or ventilation air.
Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
CAUTION: Items of interest to
children should not be placed in cabinets above
the cooktop.
- children climbing on the cooktop to reach items
could be seriously injured.
WARNING: This appliance must
not be installed with a ventilation system that
blows air downward toward the cooktop. This
type of ventilation system may cause ignition
and combustion problems with the gas cooking
appliance resulting in personal injury or unintended
operation.
INSTALLATION SAFETY INSTRUCTIONS
(continued)
6
Provide enough clearances between the cooktop and
adjacent combustible surfaces. These dimensions
must be met for safe use of your cooktop.
The location of the electrical outlet and pipe opening
may be adjusted to meet specific requirements.
The cooktop may be placed with 2 3/4” clearance to
the back wall.
DIMENSIONS AND CLEARANCES
INSTALLATION INSTRUCTIONS
A
A
C
L
1. MAINTAIN THE FOLLOWING
MINIMUM CLEARANCE
DIMENSIONS
3. RECOMMENDED GAS SUPPLY
LOCATION FROM BACKWALL
4. MAKE SURE WALL COVERINGS,
COUNTERTOP AND CABINETS
AROUND COOKTOP CAN
WITHSTAND HEAT(UP TO 200℉)
GENERATED BY COOKTOP
2. COOKTOP AND CUTOUT
DIMENSIONS
13˝MAX. Depth of unprotected
overhead cabinets
A˝ MIN. clearance from
cutout to side wall on
the right of the unit
18˝ MIN. height
from countertop
to nearest cabinet
on either side of
unit
30˝ MIN. clearance
from countertop to
unprotected overhead
surface
A˝ MIN. clearance
from cutout to side
wall on the left of
unit.
L″ MIN.
Between
cutout
and the wall
behind the
cooktop
K″ MIN.
From front
edge of cutout
and front edge
of countertop
Recommended
gas supply
location
1” Min. From Backwall
From Cutout
Center Line
To ensure accuracy, it is best to make
a template when cutting the opening
in the counter
C
width
H
width cut
L
K
D
depth
B″MIN
J
depth cut
G
depth
E
height
F
width
MODEL A B C D E F G H J K L
30″ Cooktop 11
13
/
16
30″ 30″ 21
11
/
16
3
3
/
4
28
1
/
4
19
3
/
8
28
1
/
2
19
11
/
16
1
5
/
8
2
3
/
4
36″ Cooktop 11
13
/
16
36″ 36″ 21
11
/
16
3
3
/
4
33
5
/
8
19
3
/
8
33
15
/
16
19
11
/
16
1
5
/
8
2
3
/
4
Wall covering ,
cabinets and
counterto p
must withstan d
heat up to
200°F
7
ENGLISH
INSTALLING THE COOKTOP UNIT
INSTALLATION INSTRUCTIONS
1. LOCATE ELECTRICAL OUTLET
AND GAS SHUT-OFF VALVE
BENEATH CABINET
2. INSERT COOKTOP INTO CUTOUT
Install a manual shut-off valve in the gas line
in an easily accessible location outside the
cooktop. Be sure you know how and where to
shut off the gas supply to the cooktop. Install
the electrical outlet 12˝ below the countertop.
3. LOCATE RETAINER BRACKETS
Remove the retainer brackets from the
literature package.
NEVER RE-USE
OLD FLEX
CONNECTORS.
Install a manual shut-off valve in the gas line
in an easily accessible location outside the
cooktop. Be sure you know how and where to
shut off the gas supply to the cooktop. Install
the electrical outlet 12˝ below the countertop.
Shut-Off
valve
Retainer brackets
Cooktop
Screw
Countertop
Retainer brackets
NOTE: The retainer brackets MUST be
installed to meet local codes or, in their
absence, with the National Electrical Code
ANSI/NFPA No. 70, latest edition.
4. INSTALL THE RETAINER BRACKETS
Install the retainer brackets to the bottom
of the cooktop unit. then snug the bolts
against the bottom of the countertop as
shown
Electrical
outlet 12˝
below
countertop
8
This cooktop is designed to operate at a pressure of
5” of water column on natural gas or 10” of water
column on LP, propane or butane gas.
Make sure you are supplying your cooktop with the
type of gas for which it is designed.
This cooktop is convertible for use on natural or
propane gas. When using this cooktop on LP gas,
conversion must be made by a qualified LP installer
before attempting to operate the cooktop on that gas.
For correct operation, the pressure of natural gas
supplied to the regulator should be between 5” and
13” of water column.
For LP gas, the pressure supplied must be between
10” and 13” of water column.
When checking for correct operation of the regulator,
the inlet pressure must be at least 1” more than the
operating -manifold- pressure as given above.
The pressure regulator located at the inlet of the
cooktop manifold must remain in the supply line
regardless of whether natural or LP gas is being
used.
A flexible metal appliance connector used to connect
the cooktop to the gas supply line must have an I.D.
of 5/8” and can be 3 feet max. in length for easy
installation. In Canada, flexible connectors should be
single wall metal connectors less than 6 feet in
length.
1. PROVIDE ADEQUATE GAS SUPPLY
INSTALLATION INSTRUCTIONS
Shut off the main gas supply valve before removing
the old cooktop and leave it off until the new hook-up
has been completed. Don’t forget to relight the pilot on
other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the
cooktop, the use of a CSA International-certified
flexible metal appliance connector is recommended
unless local codes require a hard-piped connection.
Never reuse an old connector when installing a
new cooktop. If the hard piping method is used, you
must carefully align the pipe; the cooktop cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound on, all
male -external- pipe threads.
1
Install a manual gas line shut-off valve in the gas
line in an easily accessed location outside of the
cooktop. Be sure everyone operating the cooktop
knows where and how to shut off the gas supply
to the cooktop.
2
Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of pressure regulator.
Use a backup wrench on the pressure regulator
fitting to prevent damage.
3
Install male 1/2” or 3/4” flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep
it from turning.
4
Connect a flexible metal connector to the adapter
on the cooktop. Position the cooktop to permit
connection at the shut-off valve.
5
When all connections have been made, be sure
all cooktop controls are in the off position and
turn on the main gas supply valve.
Check for gas leaks by using manometer.
If a manometer is not available, turn the gas
supply on to the cooktop on and use a liquid leak
detector at all joints and connections to check for
leaks.
Tighten all connections, if necessary, to prevent
gas leakage in the cooktop or supply line.
WARNING!:
DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
Disconnect the cooktop and its individual shut-off
valve from the gas supply piping system during any
pressure testing of that system at test pressures
more than 1/2 psig(3.5kPa).
Isolate the cooktop from the gas supply piping
system by closing its individual shut-off valve during
any pressure testing of the gas supply system at test
pressures equal to or less than 1/2 psig(3.5kPa)
2. CONNECT THE COOKTOP TO GAS
9
ENGLISH
INSTALLATION INSTRUCTIONS
FLEXIBLE CONNECTOR HOOKUP
Pressure
regulator
Installer: Inform the
consumer of the
location of the gas
shut-off valve.
1/2” or 3/4”
Gas pipe
Flex
connector
(6 ft. max.)
Gas Flow into Range
Adapter
Gas
shut-off valve
Adapter
10
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hertz, properly grounded dedicated
circuit protected by a 15 A or 20 A circuit breaker or
time delay fuse.
GROUNDING
IMPORTANT: FOR PERSONAL SAFETY,
THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
PREFERRED
METHOD
Ensure proper ground
exists before use
The power cord of this appliance should be equipped
with a three-prong (grounding) plug which mates with
a standard three-prong grounding wall receptacle to
reduce the possibility of electric shock hazard from
this appliance.
The customer should have the wall receptacle and
circuit checked by a qualified technician to be sure
the receptacle is properly grounded.
When connecting the cord of this cooktop to a
standard two-prong wall receptacle, it is the personal
responsibility and obligation of the customer to have
it replaced with a properly grounded three-prong wall
receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD.
A word about Ground Fault Circuit Interrupters –
Ground Fault Circuit Interrupters are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters are devices that
sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected.
These devices must be manually reset by the
customer.
The National Electrical Code requires the use of
Ground Fault Circuit Interrupters in kitchen
receptacles installed to serve countertop surfaces.
Performance of the cooktop will not be affected if it is
operated from a Ground Fault Circuit Interrupters
protected circuit but occasional nuisance can occur.
3. ELECTRICAL CONNECTIONS
INSTALLATION INSTRUCTIONS
11
ENGLISH
CAUTION
The customer should have the circuit checked by a
qualified technician to make sure the receptacle is
correctly grounded.
DO NOT use an adapter plug because disconnecting
of the power cord places undue strain on the adapter
and causes eventual failure of the adapter ground
terminal.
The customer must have the two-prong wall
receptacle replaced with a three-prong (grounding)
receptacle by a qualified technician before using this
cooktop.
The installation of appliances designed for mobile
home installation should conform with the
Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280) or, when such
standard is not applicable, the Standard for
Manufactured Home Installations, latest edition
(Manufactured Home Sites, Communities and Set-
Ups), ANSI A225.1, latest edition, or with local
codes. In Canada, mobile home installation must
comply with the current CAN/CSA Z240/MH Mobile
Home Installation Code
3. ELECTRICAL CONNECTIONS
(continued)
INSTALLATION INSTRUCTIONS
Seal any openings in the wall behind the cooktop
and in the floor of the cabinet when hookups are
completed.
4. SEAL THE OPENINGS
12
CAUTION
DO NOT operate the burners without all parts in
place.
Place the burner caps and heads on the cooktop.
Make sure that the caps and heads are placed in the
correct locations.
Small burner
head and cap
Lrage burner
head and cap
Medium burner
head and cap
Extra large burner (Center)
head and cap
Make sure the hole in the burner head is positioned
over the electrode.
Hole
Electrode
5. ASSEMBLE THE SURFACE BURNERS
INSTALLATION INSTRUCTIONS
Operation of all cooktop burners should be checked
after the COOKTOP and gas supply lines have been
carefully checked for leaks.
ELECTRIC IGNITION
Select a top burner knob, push down and then turn
counterclockwise to the “LITE” position.
You can hear a clicking sound indicating proper
operation of the spark module.
Once the air has been purged from the supply lines,
burner should ignite within 4 seconds.
After burner ignites, rotate knob out of the “LITE”
position. Try each burner in succession until all
burners have been checked.
ELECTRIC IGNITION
The combustion quality of burner flames needs to be
confirmed visually.
A Yellow flames — Call for service
B Yellow tips on outer cones
— It is normal for LP gas
C Soft blue flames
— It is normal for natural gas
If burner flames look like A, call for service.
B or C is normal burner flames, depending on the
type of gas you use.
With LP gas, some yellow tipping on outer cones is
normal.
6. CHECK IGNITION OF SURFACE BURNERS
13
ENGLISH
For all surface burners except for the center
burner
1. Light all surface burners except for the center
burner.
2. Turn the knob on the burner being adjusted to LO
(LOW).
3. Remove knob.
4. Insert a small, flat bladed screwdriver into the
valve stem as shown in Fig.2.
5. Turn the adjustment screw until the flame reaches
the desired size.
6. Replace the knob.
Center adjustment screw
Fig. 2
7. Test The Flame Stability.
Test 1 :
• Turn the knob from HI to LOW quickly.
lf the flame goes out, increase the flame size a
nd test again.
Test 2 :
With the burner on a LOW setting, open and
close the oven or cabinet door quickly.
If the flame is extinguished by the air currents
created by the door movement, increase the
flame height and test again.
8. Repeat steps 1 - 6 for each surface burner except
for the center burner.
Only For the center burner
1. Disconnect power to appliance.
2. Remove grates, burners caps, burner heads and
knobs.
3. Remove all the screws on the cooktop with a
philips screwdriver.
4. Remove the cooktop by lifting it up.
5. Remove LED lamp module of the center valve by
unclipping. In this case, the ignition switch should
be positioned properly.
6. Replace the cooktop and secure the screws of the
cooktop.
7. Position center burner head, center burner cap,
center grate, and center knob.
8. Connect power to the appliance.
9. Light center burner.
10. Turn the knob on the burner being adjusted to LO
(LOW).
11. Remove knob.
12. Using a small, flat bladed screwdriver insert into
the hole next to the valve stem to adjust the outer
flame as shown in Fig.3.
13. Turn the adjustment screw until the flame
reaches the desired size.
14. Replace the knob.
Adjustment screw next to the valve shaft
Fig. 3
15. Test The Flame Stability.
Test 1 :
• Turn the knob from HI to LOW quickly.
If the flame goes out, increase the flame size
and test again.
Test 2 :
With the burner on a LOW setting, open and
close the oven or cabinet door quickly.
If the flame is extinguished by the air currents
created by the door movement, increase the
flame height and test again.
16. After setting the low flame, turn off the burner.
17. Disconnect power to the appliance.
18. Remove knob, grate, burner cap, and burner
head.
19. Remove all screws from the cooktop.
20. Remove the cooktop by lifting up.
21. Replace the center LED lamp module.
22. Replace the cooktop and secure all screws.
23. Replace burner heads, burner caps, grates and
knobs.
24. Connect power to appliance.
7. ADJUST THE SURFACE BURNER LOW FLAME
(SIMMER) SETTING
INSTALLATION INSTRUCTIONS
14
Make sure all controls are left in the off position.
Make sure the flow of combustion and ventilation air
to the cooktop is unobstructed.
WHEN ALL HOOKUPS ARE COMPLETE
INSTALLATION INSTRUCTIONS
This cooktop leaves the factory set for use with
natural gas. When converting to LP gas, the
conversion must be performed by a qualified LP
gas installer.
The conversion instructions and LP orifices are
supplied with your cooktop.
Keep these instructions and the orifices in case you
want to convert back to natural gas.
CONVERTING TO LP GAS
(OR CONVERTING BACK TO NATURAL GAS FROM LP)
GUIDE D'INSTALLATION
SURFACE DE
CUISSON AU GAZ
Veuillez lire attentivement ce guide avant de procéder à l'installation.
P/No.: MFL62725506
www.lg.com
FRANÇAIS
LSCG366ST
LSCG306ST
LSCG367ST
LSCG307ST
2
NOTICE D'INSTALLATION
CONSIGNES DE SÉCURITÉ RELATIVES À L'INSTALLATION
AVANT DE COMMENCER
Lisez les consignes attentivement et en
entier.
L'installation de la surface de cuisson doit être
conforme aux codes locaux ou, en l'absence de
ces derniers, à la dernière édition du National
Fuel Gas Code, ANSI Z223.1 / NFPA.54. Au
Canada, l'installation doit être conforme au Code
d'installation du gaz naturel CAN / CGAB149.1 ou
au Code d'installation du propane, CAN / CGA-
B149.2 ainsi qu'aux codes locaux, le cas échéant.
La conception de la surface de cuisson a été
certifiée par CSA International, conformément à
la dernière édition de la norme ANSI Z21.1, et par
l'Association canadienne du gaz conformément à
la dernière édition de la norme CAN/CGA-1.1.
Comme pour tout appareil fonctionnant au
et générant de la chaleur, vous devez suivre
certaines mesures de sécurité. Ces mesures
figurent dans la section Consignes importantes de
sécurité, du Guide de l'utilisateur. Veuillez les lire
attentivement.
IMPORTANT Conservez la notice
d'installation qui sera utile à l'inspecteur en
électricité.
IMPORTANT Nous vous invitons à
respecter tous les codes et règlements en
vigueur.
Note à l'intention de l'installateur : Veuillez
laisser la notice d'installation avec l'appareil à la fin
de l'installation.
Note à l'intention de l'utilisateur : Conservez ce
Guide d'installation et le guide de l'utilisateur pour
consultation ultérieure.
NOTE : Cet appareil doit être correctement mis
à la terre
Le schéma électrique se trouve dans une
enveloppe attachée à l'arrière de la surface de
cuisson.
Niveau de compétence - L'installation de cet
appareil nécessite des compétences mécaniques
de base.
L'installateur a la responsabilité d'installer
correctement l'appareil.
Toute défectuosité de l'appareil attribuable à une
mauvaise installation n'est pas couverte par la
garantie.
Retirez tous les adhésifs ainsi que l'emballage.
Assurez-vous que les brûleurs sont bien en place
et au niveau.
Retirez le sac d'accessoires de la surface de
cuisson.
Assurez-vous qu'aucune pièce de la surface de
cuisson ne s'est desserrée pendant le transport.
3
FRANÇAIS
DANS LE COMMONWEALTH DU MASSACHUSETTS
PRÉPARATION À L'INSTALLATION
POUR VOTRE SÉCURITÉ
Ce produit doit être installé par un plombier ou par un
installateur de gaz agréé.
Lors de l'utilisation de vannes d'arrêt de gaz à bille, celles-
ci doivent être munies d'une poignée en T.
Lors de l'utilisation d'un connecteur de gaz flexible,
celui-ci, ne doit pas excéder 3 pieds (92 cm) de
longueur.
NOTICE D'INSTALLATION
LISEZ TOUTES LES CONSIGNES AVANT L'INSTALLATION
AVERTISSEMENT :
Si
les consignes énoncées dans ce manuel ne
sont pas suivies à la lettre, il pourrait s'en suivre
un incendie ou une explosion entraînant des
dommages matériels, des blessures ou la mort.
Ne pas entreposer ou utiliser des matériaux
combustibles, de l'essence ou d'autres
vapeurs et liquides inflammables à proximité
de tout appareil.
QUE FAIRE SI VOUS DÉTECTEZ UNE ODEUR DE GAZ
• Ne mettez aucun appareil sous tension.
• Ne touchez à aucun commutateur électrique.
N'utilisez aucun téléphone dans votre maison ou immeuble.
Appelez immédiatement votre fournisseur de
gaz à partir du téléphone d'un voisin. Suivez les
instructions du fournisseur de gaz.
Si vous ne pouvez pas communiquer avec votre
fournisseur de gaz, appelez le service d'incendie.
L'installation et l'entretien doivent être effectués
par un installateur qualifié, une agence de
service ou le fournisseur de gaz.
OUTILS DONT VOUS AUREZ BESOIN
MATÉRIAUX DONT VOUS AUREZ BESOIN
MATÉRIAUX DONT VOUS AUREZ BESOIN
• Vanne d'arrêt de la conduite de gaz
Pour réduire tout risque de fuite de gaz, appliquez
sur tous les raccords filetés du ruban téflon ou un
dégrippant pouvant être utilisé avec du PL ou du
gaz naturel.
Un connecteur en métal souple (5/8 po de diamètre
intérieur) d'une longueur de 3 pieds (95 cm) est
recommandé pour faciliter l'installation, mais
d'autres longueurs sont acceptables.
Ne jamais utiliser un ancien connecteur lors de
l'installation d'une nouvelle surface de cuisson.
Adaptateur évasé pour le raccordement tuyau
d'alimentation (3/4 po ou 1/2 po PTN x 5/8 po de
diamètre intérieur)
Adaptateur évasé pour raccordement au régulateur
de pression sur la surface de cuisson.
(1/4 po PTN x 1/2 po de diamètre intérieur)
• Détecteur liquide de fuite ou eau savonneuse.
Tournevis Phillips
Joint
d'étanchéité
Raccords de
tuyaux
Connecteur flexible
Vanne d'arrêt
Clé à molette ou à
fourche
Clé à tube (2)
(une pour le soutien)
Tournevis à tête plate
Crayon et règle
4
IMPORTANT : Retirez tous les matériaux
d'emballage et la documentation avant de procéder
à l'approvisionnement en gaz et au raccordement
électrique.
Faites installer votre surface de cuisson par un
technicien qualifié.
Votre surface de cuisson doit être mise à la terre
conformément aux normes locales ou, en l'absence
de ces normes, en conformité avec le Code
national de l'électricité (ANSI / NFPA 70, dernière
édition). Au Canada, la mise à la terre électrique
doit être en conformité avec la partie 1 de la norme
CSA C22.1 du Code canadien de l'électricité ou
avec les codes locaux.
Reportez-vous à la section 3. Connexions
électriques, dans le présent manuel.
Assurez- vous que les revêtements muraux autour
de la surface de cuisson peuvent résister à la
chaleur générée celle-ci, c'est à dire jusqu'à
200° F.
Évitez de placer des armoires au-dessus de la
surface de cuisson.
Afin de réduire les risques lorsque vous passez
les mains au-dessus des flammes, installez une
hotte aspirante au-dessus de la surface de cuisson.
Cette hotte aspirante doit dépasser la façade des
armoires d'au moins 5 po.
CONSIGNES DE SÉCURITÉ RELATIVES À L'INSTALLATION
NOTICE D'INSTALLATION
Ce symbole indique une alerte à la sécurité. Ce symbole vous avertit des risques
potentiels de blessures graves ou même de mort qui peuvent survenir pour vous et
toute autre personne. Tous les messages de sécurité seront mentionnés à la suite du
symbole d'alerte à la sécurité et des mots "AVERTISSEMENT" ou "MISE EN GARDE".
AVANT DE COMMENCER
Retirez tous les rubans et matériaux d'emballage avant d'utiliser la surface de cuisson. Jetez tous
les sacs en plastique après le déballage de la surface de cuisson. Ne jamais laisser les matériaux
d'emballage à la portée des enfants.
MESURES DE SÉCURITÉ IMPORTANTES
Lisez ces consignes attentivement et en entier. Toute installation, réglage, modification, service ou
entretien inapproprié peut causer des blessures ou des dommages matériels.
Pour obtenir de l'aide ou des renseignements supplémentaires, consultez un installateur qualifié,
une agence de service, le fabricant (détaillant) ou votre fournisseur de gaz.
Ne réutilisez jamais des connecteurs flexibles usés. L'utilisation de connecteurs flexibles usés peut
provoquer des fuites de gaz et des blessures. Utilisez toujours des connecteurs flexibles neufs lors
de l'installation d'un appareil fonctionnant au gaz.
Ce symbole vous prévient des risques ou pratiques
dangereuses pouvant causer des lésions corporelles graves
ou la mort.
AVERTISSEMENT
Ce symbole vous prévient des risques ou pratiques
dangereuses qui pourraient causer des blessures corporelles
ou des dégâts matériels.
MISE EN GARDE
5
FRANÇAIS
NOTICE D'INSTALLATION
La hotte de ventilation doit être fabriquée avec une
tôle en feuille d'au moins 0,0122 po d'épaisseur.
Installez-la au-dessus de la surface de cuisson, en
laissant un espace libre d'au moins 1/4 po entre la
hotte et la face inférieure de la matière combustible
ou de l'armoire métallique. La hotte doit être au
moins aussi large que l'appareil et orientée au
centre de l'appareil. L'intervalle entre la surface de
cuisson et la surface de la hotte de ventilation NE
DOIT JAMAIS ÊTRE INFÉRIEUR À 24 POUCES.
EXCEPTION : L'installation d'un four à micro-ondes
inscrit au répertoire ou d'un appareil de cuisson
au-dessus de la surface de cuisson devra être
conforme à la notice d'installation fournie avec cet
appareil.
Si les armoires sont situées au-dessus de la
surface de cuisson, laissez un dégagement d'au
moins 30 po entre la surface de cuisson et le fond
des armoires non protégées.
Si un dégagement de 30 po (76 cm) entre la
surface de cuisson et les matériaux ou les armoires
métalliques ne peut être maintenu, protégez la
partie inférieure des armoires au-dessus de la
surface de cuisson à l'aide d'un isolant de carton
d'une épaisseur d'au moins 1/4 po (0,5 cm)
recouvert d'une tôle en feuille d'au moins 0,0221 po
(3 mm) d'épaisseur. Les intervalles entre la surface
de cuisson et les armoires protégées ne doivent
jamais être inférieurs à 24 pouces.
La distance verticale séparant la surface de cuisson
et le bas des armoires adjacentes doit être de
moins de 1 po par rapport aux côtés de la surface
de cuisson et ne doit pas être inférieure à 18 po.
(Voir les illustrations indiquant les dimensions et les
dégagements dans le présent manuel.)
Ne pas obstruer l'air de combustion ou la
ventilation.
Les essais d'étanchéité doivent être effectués selon
les instructions du fabricant.
MISE EN GARDE : Les
éléments présentant un intérêt pour les enfants
ne devraient pas être placés dans des armoires
situées au-dessus de la surface de cuisson.
- Les enfants peuvent se blesser gravement en
grimpant sur la surface de cuisson pour atteindre
ces objets.
AVERTISSEMENT : Cet
appareil ne doit pas être installé avec un système
de ventilation qui souffle de l'air vers la surface
de cuisson. Ce type de système de ventilation
pourrait occasionner des problèmes d'allumage
et de combustion entraînant des blessures ou un
fonctionnement inattendu.
CONSIGNES DE SÉCURITÉ RELATIVES À L'INSTALLATION
(suite)
6
Laissez suffisamment d'espace entre la surface de
cuisson et les surfaces combustibles adjacentes. Ces
dimensions doivent être respectées pour assurer une
utilisation sécuritaire de la surface de cuisson.
L'emplacement de l'orifice de sortie et de la conduite
électrique peut être ajusté pour satisfaire à des
exigences spécifiques.
Un dégagement de 2 3/4 po peut être prévu entre la
surface de cuisson et le mur arrière.
DIMENSIONS ET DÉGAGEMENTS
NOTICE D'INSTALLATION
A
A
C
L
1. IL EST OMPORTANT DE MAINTENIR
LES DISTANCES MINIMALES DE
DÉGAGEMENT SUIVANTES :
3.
EMPLACEMENT RECOMMANDÉ DE
L'ALIMENTATION EN GAZ À PARTIR DU
MUR ARRIÈRE
2. SURFACE DE CUISSON ET
DIMENSIONS DES DÉCOUPES
MAX 13 po de profondeur pour les
armoires supérieures non protégés
A˝ MIN. Dégagement de la
découpe à la paroi latérale
à droite de l'appareil
Hauteur MIN. de
18 po du plan de
travail jusqu'à
l'armoire la plus
proche de chaque
côté de l'appareil
Dégagement MIN. de
30 po du comptoir à la
surface supérieure non
protégée
A˝ MIN. Dégagement
allant de la découpe
jusqu'à la paroi latérale
à droite de l'appareil
L″ MIN.
Entre la
découpe et le
mur derrière
la surface de
cuisson
K″ MIN.
A partir du bord avant
de la découpe et du
bord avant du comptoir
Emplacement
recommandé pour
l'alimentation en
gaz
Au moins 1 po à partir du mur arrière
À partir de la
ligne centrale
de découpe
Pour garantir la précision, il est
préférable de créer un modèle lors de
la découpe de l'ouverture dans le
comptoir.
C
Largeur
H
largeur de coupe
L
K
D
Profondeur
B″MIN
J
profondeur de coupe
G
Profondeur
E
Hauteur
F
Largeur
MODÈLE A B C D E F G H J K L
Surface de
cuisson de 30 po
11
13
/
16
po 30 po 30 po 21
11
/
16
po 3
3
/
4
po 28
1
/
4
po 19
3
/
8
po 28
1
/
2
po 19
11
/
16
po 1
5
/
8
po 2
3
/
4
po
Surface de
cuisson de 36 po
11
13
/
16
po 36 po 36 po 21
11
/
16
po 3
3
/
4
po 33
5
/
8
po 19
3
/
8
po
33
15
/
16
po
19
11
/
16
po 1
5
/
8
po 2
3
/
4
po
Les revêtements des
murs, des armoires et du
comptoir doivent résister
à une température
pouvant atteindre 200 °F.
4.
ASSUREZ-VOUS QUE LES
REVÊTEMENTS MURAUX, LE
COMPTOIR ET LES ARMOIRES
AUTOUR DE LA SURFACE DE
CUISSON PEUVENT RÉSISTER À LA
CHALEUR (JUSQU'À 200 ℉) GÉNÉRÉE
PAR LA SURFACE DE CUISSON
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

LG LSCG307ST Mode d'emploi

Catégorie
Cuisinières
Taper
Mode d'emploi

dans d''autres langues