Zephyr AK1100B Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
WWW.ZEPHYRONLINE.COM
SEP20.0601
Breeze I
AK1124Bx, AK1100Bx, AK1136Bx
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
Breeze II
AK1200Bx, AK1236Bx
2
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
3
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information ............................................................................ 4-9
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................5-8
Operation ........................................................................................... 8
Electrical Requirements .....................................................................8-9
List of Materials .................................................................................. 10
Installation Instructions ....................................................................11-20
Ducting Calculation Sheet ..................................................................11
Mounting Height, Clearance, & Ducting .......................................... 12-13
Ducting Options .................................................................................14
Hood Specifications ............................................................................15
Electrical Supply .................................................................................16
Cable Lock .........................................................................................16
Installation Preparation ......................................................................17
Air Recirculating Mode Conversion .................................................. 18-19
Mounting the Hood ............................................................................ 20
Features & Controls ............................................................................ 21
Maintenance ................................................................................... 22-24
Hood & Filter Cleaning .....................................................................22-23
LumiLight LED & LED Light Strip ........................................................ 24
Wiring Diagram ..................................................................................25
Troubleshooting.................................................................................. 26
List of Parts & Accessories .................................................................. 27
Notes ..................................................................................................28
Limited Warranty ............................................................................... 29
Product Registration ...........................................................................30
4
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual for your appliance. Always read
and obey all safety messages.
This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe
bodily injury or death. All safety messages will follow the Safety Alert Symbol and either the words
DANGER” “WARNING” or “CAUTION
DANGER
WARNING
CAUTION
Danger means that failure to heed this safety
statement may result in severe injury or death.
Warning means that failure to heed this safety
statement may result in extensive product damage,
serious personal injury, or death.
Caution means that failure to heed this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
5
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING
General Safety
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
CAUTION
6
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
7
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING
8
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Ź To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
Ź Not for use over an outdoor grill.
Ź For indoor use only.
Ź Do not use over cooking equipment greater than 60,000 BTU/hr.
Ź This hood is not intended to be used as a shelf.
CAUTION
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could
catch onto hair, fingers and loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given
here for installation, maintenance and suitable use of the product. The manufacturer further
declines all responsibility for injury due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility to be aware of these below:
Ź To contact a qualified electrical installer.
Ź To assure that the electrical installation is adequate and in conformance with National Electrical
Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
9
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
READ AND SAVE THESE INSTRUCTIONS
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly
grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire with ground. Please also refer to Electrical Diagram on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements, purchase and install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
10
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
List of Materials
Parts Supplied
Quantity Part
1Hood
2 Aluminum mesh filters
2 LumiLight LED, 6W (Breeze I only)
1 LED Light Strip, 5W (Breeze II only)
1 3-1/4”x10” rectangular starting collar with
damper (located inside hood body)
1 Hardware package
#6 x 1” (4)
#6 x 1-1/2” (4)
#6 x 2” (4)
M4 x 8” (10)
Wood screw washers (4)
Wire Caps (3)
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Duct cover extension kit (0AK11-21001)
11
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Duct pieces
To t al
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
To t al
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Ducting Calculation Sheet
12
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Installation Instructions
Mounting Height, Clearance, & Ducting
36”
20” min.
24” min.
32” max.
NOTE: The Breeze I minimum mount height for electric cook tops is 20”, but is 24” for gas cook tops.
The Breeze II minimum mount height for both electric and gas cook tops is 24”. The maximum
mount height for both Breeze I and Breeze II is 32” for both electric and gas cook tops.
13
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum 3-1/4”x10” rectangular duct for either vertical ducting or horizontal ducting must be used
to maintain maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Use calculation worksheet to compute total available duct run when using elbows, transitions, and
caps.
ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required,
increase duct size.
If turns or transitions are required: Install as far away from duct opening and as far apart between
the two transitions as possible.
Breeze I: Minimum mount height between range top to hood bottom should be no less than 20” for
electric cook tops and 24” for gas cook tops. Maximum mount height should be no higher than 32”.
Breeze II: Minimum mount height between range top to hood bottom should be no less than 24”
Maximum mount height should be no higher than 32”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose
performance and eciency.
If available, also refer to range manufacturer’s height clearance requirements and recommended
hood mounting height above range. Always check your local codes for any dierences.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
14
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Installation Instructions
Ducting Options
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Roof Pitch w/
Flashing & Cap
Rear Ducting
3-1/4”x10”
vertical ducting
3-1/4”x10”
horizontal ducting
Air Recirculating
15
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ů
35-15/16” (36”)
29-15/16” (30”)
23-15/16” (24”)
33-7/8” (36”)
27-7/8” (30”)
22-1/16” (24”)
33-5/8” (36”)
27-5/8” (30”)
21-5/8” (24”)
2-3/4”
C/L
8-5/8”
1-3/8”
9-1/16”
2”
12-3/16”
10-7/8”
3/4”
9-1/16”
elec.
k/o
elec.
k/o
5-1/2”
14-3/8”
19-5/16
20-3/32”
TOP
BACK SIDE
1/2”
1/2”
10”
3-1/4”
10”
3-1/4”
C/L
Air Recirculating Louver Plate
2.2°
2.
78.
16
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
17
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Installation Preparation
ŚĘŮ
śĘ
Ĭśĭ
Ę
ŜĘĕ
    
Ę
   Ę  
ĕ
Ę
ŝĘ      
ŝŞĘ
ŜĚŚħŝĢŚřĢ
Ě      
Ę
ŞĘŜĚŚħŝĢŚřĢ
     
ĬŚřĭŝšĢĘ
ė
Ę
18
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Installation Instructions
Air Recirculating Mode Conversion
An air recirculating kit (optional) must be
purchased before using hood in recirculat-
ing mode.
Recirculating kit - 0AK11-21001
ŮĚřŚŚĚśřřřŚ
1. Secure each of the (2) spring clips to the
safety grille body (A). Do this by inserting
the screw through the spring and into the
clip. Secure each clip to the safety grille
body by using a philips head screwdriver.
śĘŮŮ
holder and place it over the safety grille
body
ŜĘŮ
grill body by lifting up on spring clips and
twisting. The clip should cover the lip of
ŮĘ
4. Remove each screw from recirculating
top plate. Plate is located on top of hood
towards the front.
NOTE: Skip the recirculating preparation pages if you are ducting the air out of your home.
19
Breeze I & Breeze II Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Air Recirculating Mode Conversion
5. Remove each of the 5 screws holding
the (2) interior recirculating panels.
6. Remove (2) interior recirculating panels.
7. Place louvered recirculating plate over
top opening and secure using the screws
previously removed.
NOTE: Skip this page if you are ducting the air out of your home.
20
Breeze I & Breeze II Use, Care, and Installation Guide
BREEZE I &
BREEZE II
UNDERCABINET
CORE
Installation Instructions
Mounting the Hood
Hood is designed for installation under a kitchen
cabinet (FIG. B)
1. Select preferred duct location (vertical or
horizontal) if ducting out of kitchen. Refer to
page 14 for details.
2. Begin installation by removing the filters (if
installed) and side spacer panels (36” models
only). (FIG. C)
3. Reinforce cabinet with 1”x2” wood strips if
additional strengthening is required or if
cabinets are framed.
4. Temporarily position the range hood in the
desired mounting location. Measure and
mark the mounting holes, duct and electrical
locations with a pencil.
5. Drill/cut out the required openings for duct and
electrical access by following the dimensions
on page 15; make sure the duct opening is
large enough to apply duct tape.
6. Fasten hood onto cabinet with (4) #6 wood
screws with washers provided.
7. Install electrical.
8. Install duct work and seal with duct tape.
9. Reinstall filters and side spacer panels (if
applicable).
10. Power up hood and check for leaks around
duct tape.
11. If recirculating the hood refer to page 18 and 19
for details.
Duct/silver
tape
Duct
opening cutout
Add 1x2
wood strips
Electrical
FIG. B
Push in on panel latch and then pull panel down
FIG. C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Zephyr AK1100B Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

dans d''autres langues