Kichler 45130NICS Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

IS-44381-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
D
H
A
C
I
B
F
E
G
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[D]
Thread mounng screws[C] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap[A] to outlet box[B] using the
strap mounng screws[E]. Mounng strap can be
adjusted to suit posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting
Strap
[B] Outlet Box
[C] Mounting
Screws
[D] Canopy
[E] Strap
Mounting
Screws
[F] Lockup Knobs
[G] Lockwashers
[H] Glass
[I] Socket Ring
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall carefully aligning the mounng
screws with holes in canopy. NOTE: Fixture can be
mounted with glass in the up or down posion. Make
sure all wires are inside canopy and do not get pinched
between canopy and wall.
6) Place the lock washers[G] onto the mounng screws
and thread lockup knobs[F] onto mounng screws and
ghten to secure xture to wall.
7) Carefully place the glass[H] over the socket to the
xture. Slip the smaller opening over the socket and t
the glass against the socket.
8) Thread the socket ring[I] onto the socket. Tighten socket
ring to secure glass in place. (DO NOT over ghten.)
9) Insert recommended bulb (not supplied).
Installaon Instrucons (connued)
IS-44381-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
1) Encuentre los oricios roscados apropiados en la
abrazadera de montaje[A] que se alinean con la distancia
de los oricios en el escudete[D]. Atornille los tornillos
de montaje[C] en los oricios roscados comenzando por
el lado de la caja de salida[B].
2) Acople la abrazadera de montaje[A] a la caja de salida[B]
con los tornillos de montaje de la abrazadera[E]. La
abrazadera de montaje se puede ajustar para acomodar
la posición del artefacto.
3) Instrucciones de conexión a erra solamente para los
Estados Unidos. (Vea la ilustracion a o b).
a) En las lámparas que enen el eje, de montaje con
un agujero y dos hoyuelos realzados, enrollar el
alambre a erra de la caja tomacorriente alrededor
del tornillo verde y pasarlo por el aquiero.
b) En las lámparas con una arandela acopada, jar el
alambre a erra de la caja tomacorriente del ajo de la
arandela acoada y tornillo verde, y paser por el eje
de montaje.
Si la lámpara viene con alambre a erra, conecter el
alambre a erra de la lámpara al alambre a erra de la
caja tomacorriente con un conector de alambres (No
incluido) espués de seguir los pasos anteriores. Nunca
conectar el alambra a erra a los alambres eléctros negro
o blanco.
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
a
b
Diagrama de Accesorios
Lista de Partes
Precauciones
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA –
Desconecte la electricidad en el panel principal del
interruptor automáco o caja principal de fusibles antes de
comenzar y durante la instalación.
ADVERTENCIA:
Este accesorio está desnado a la instalación de
acuerdo con el Naonal Electrical Code (NEC) y todas las
especicaciones del código local. Si no está familiarizado
con los requisitos del código, la instalación se recomienda
un electricista cercado.
Instrucciones de Instalación
[A] Abrazadera de
Montaje
[B] Caja de Salida
[C] Tornillos de
Montaje
[D] Escudete
[E] Tornillos de
Montaje de la
Abrazadera
[F] Perillas de
Sujeción
[G] Arandelas
de Seguridad
[H] Vidrio
[I] Anillo del
Portalámparas
D
H
A
C
I
B
F
E
G
Instrucciones de Instalación (connuación)
4) Haga les conexiones de los alambres. La tabla de
referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo
y liso)
*Cordon paralelo (cuadrado
y estriado)
Claro, marrón, amarillio
o negro sin hebra
idencadora
Claro, marrón, amarillio
o negro con hebra
idencadora
Alambre aislado (diferente
del verde) con conductor
de cobre
Alambre aislado (diferente
del verde) con conductor
de plata
*Nota: Cuando se uliza alambre
paralelo (SPT 1 y SPT 2). El alambre
neutro es de forma cuadrada o
estriada y el otro alambre será
de forma redonda o lisa. (Vea la
ilustracíón).
Hilo Neutral
5) Empuje el artefacto a la pared alineando
cuidadosamente los tornillos de montaje con los oricios
en el escudete. NOTA: El artefacto puede instalarse con
el vidrio hacia arriba o hacia abajo. Asegúrese de que todos
los cables estén dentro del escudete y no pellizcado entre el
escudete y la pared.
6) Coloque la arandelas de seguridad[G] en los tornillos
de montaje y enrosque las perillas de sujeción[F] en
los tornillos de montaje y ajústelas para asegurar el
artefacto a la pared.
7) Coloque con cuidado el vidrio[H] sobre el portalámparas
al artefacto. Deslice la pequeña abertura sobre el
portalámparas y encaje el vidrio contra el portalámparas.
8) Enrosque el anillo del portalámparas[I] en el
portalámparas. Ajuste el anillo del portalámparas y
asegure el vidrio en posición. (NO AJUSTE en exceso).
9) Inserte la bombilla recomendada (no suministrada).
IS-44381-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
D
H
A
C
I
B
F
E
G
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[D]
Thread mounng screws[C] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap[A] to outlet box[B] using the
strap mounng screws[E]. Mounng strap can be
adjusted to suit posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting
Strap
[B] Outlet Box
[C] Mounting
Screws
[D] Canopy
[E] Strap
Mounting
Screws
[F] Lockup Knobs
[G] Lockwashers
[H] Glass
[I] Socket Ring
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall carefully aligning the mounng
screws with holes in canopy. NOTE: Fixture can be
mounted with glass in the up or down posion. Make
sure all wires are inside canopy and do not get pinched
between canopy and wall.
6) Place the lock washers[G] onto the mounng screws
and thread lockup knobs[F] onto mounng screws and
ghten to secure xture to wall.
7) Carefully place the glass[H] over the socket to the
xture. Slip the smaller opening over the socket and t
the glass against the socket.
8) Thread the socket ring[I] onto the socket. Tighten socket
ring to secure glass in place. (DO NOT over ghten.)
9) Insert recommended bulb (not supplied).
Installaon Instrucons (connued)
IS-44381-CB
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
INSTRUCTIONS:
For Assembling and Installing Fixtures in Canada
Pour Lassemblage et L’installaon Au Canada
1) Trouvez les trous letés appropriés sur l’étrier de
montageA] qui sont alignés sur la distance entre les trous
du canopée[D]. Vissez les vis de montage[C] dans les
trous letés en commençant par le côté du boîe à prises
[B].
2) Fixer l’étrier de montage[A] sur la boîte à prises[B]
à laide des vis de xaon de létrier[E]. Létrier de
montage peut être réglé en foncon de la posion du
luminaire.
3) Connecter les ls. Se reporter au tableau ci-dessous pour
faire les connexions.
Connecter le l noir ou
rouge de la boite
Connecter le l blanc de
la boîte
A Noir A Blanc
*Au cordon parallèle (rond
et lisse)
*Au cordon parallèle (à
angles droits el strié)
Au transparent, doré,
marron, ou noir sans l
disncf
Au transparent, doré,
marron, ou noir avec un l
disncf
Fil isolé (sauf l vert) avec
conducteur en cuivre
Fil isolé (sauf l vert) avec
conducteur en argent
*Remarque: Avec emploi d’un
l paralléle (SPT 1 et SPT 2). Le
l neutre est á angles droits ou
strié et lautre l doit étre rond
ou lisse (Voir le schéma).
Fil Neutre
4) Poussez le luminaire vers le mur en alignant
soigneusement les vis de montage avec les trous dans
le canopée . REMARQUE : Le luminaire peut être monté
avec le verre en posion vers le haut ou vers le bas.
Assurez-vous que tous les ls sont à l’intérieur de la
canopée et ne pas être pincés entre la canopée et le mur.
5) Placez les rondelles de blocage[G] sur les vis de montage
et vissez les boutons de blocage[F] sur les vis de
montage. Serrez pour xer le luminaire au mur.
6) Placez délicatement le verre[H] sur la prise du luminaire.
Glissez la plus pete ouverture sur la douille et placez le
verre contre la douille.
7) Serrez l’anneau de douille[I] sur la douille. Resserrez la
vis pour xer le verre (NE PAS serrer avec excès).
8) Installer l’ampoule recommandée (non fournie).
Diagramme d’appareils
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installaon.
ATTENTION:
Ce luminaire doit être installé conformément aux codes
d’électricité naonaux (NEC) et sasfaire toutes les
spécicaons des codes locaux. Si vous ne connaissez pas
les exigences de ces codes, il est recommandé de coner
l’installaon à un électricien ceré.
Liste des Pièces
Précauons
Instrucons d’installaon
[A] Létrier De
Montage
[B] Boîte À Prises
[C] Vis de
Montage
[D] Canopée
[E] Vis de
Fixation de
L’étrier
[F] Boutons de
Blocage
[G] Rondelles de
Blocage
[H] Verre
[I] Lanneau de
Douille
D
H
A
C
I
B
F
E
G
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler 45130NICS Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues