1) Find the appropriate threaded holes on mounng strap[A] that
align with hole distance in canopy. Thread mounng screws[D] into
threaded holes starng from outlet box[B] side.
2) Aach mounng strap to outlet box with strap mounng screws[C].
Mounng strap can be adjusted to suit posion of xture.
3) Grounding instrucons: (See Illus. I or II).
a) On xtures where mounng strap is provided with a hole and
two raised dimples. Wrap ground wire from outlet box around
green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided. Aach ground
wire from outlet box under cupped washer and green ground
screw, and thread into mounng strap.
If xture is provided with ground wire. Connect xture ground wire
to outlet box ground wire with wire connector (not provided.) aer
following the above steps. Never connect ground wire to black or
white power supply wires.
4) Make wire connecons. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other than
green) with copper conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT
2) are used. The neutral wire is square
shaped or ridged and the other wire
will be round in shape or smooth
(see illus.)
Neutral Wire
5) Push xture to wall carefully passing mounng screws with holes
in canopy. Note: xture can be mounted with glass in the up or
down posion. Make sure all wires are inside canopy and do not get
pinched between wall and canopy of xture.
6) Place the two (2) lockwashers[G] onto screws coming through
canopy and thread the two (2) lockup knobs[H] onto mounng
screws and ghten to secure xture to wall.
7) Insert recommended bulb[E] (not supplied).
8) Carefully raise glass[F] to the xture. Slip the smaller opening over
the socket and t the glass against the socket cover and gently rotate
clockwise into place.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
I
II
Fixture Diagram
Parts List
[A] Mounting Strap
[B] Outlet Box
[C] Strap Mounting
Screws
[D] Mounting
Screws
[E] Bulb
[F] Glass
[G] Lockwashers
[H] Lockup Knobs
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
B
F
A
C
E
D
G