Blitz TWIN Works 530/300 H Le manuel du propriétaire

Catégorie
Compresseurs d'air
Taper
Le manuel du propriétaire
TWIN Logos/Works
I Istruzioni d‘uso
GB Operating Instructions
F Notice d’utilisation
D Bedienungsanleitung
NL Bruksanvisning
DK Betjeningsvejledning
E Instrucciones para el manejo
P Instruções de utilização
Typ
Seriennummer
Datum
Rev. B 120953 05/2019
2
IT
Prima di posizionare, mettere in funzione o intervenire sul compressore, leggere attentamente il libretto istruzioni.
UK
READ THE INSTRUCTION HANDBOOK
Before positioning, operating or adjusting the compressor, read the instruction handbook carefully.
FR
LIRE LA NOTICE D'INSTRUCTIONS
Avant de positionner, mettre en service ou intervenir sur le compresseur, lire attentivement la notice d'instructions.
DE
GEBRAUCHSANLEITUNG LESEN
Lesen Sie die Gebrauchsanleitung sorgfältig durch, bevor Sie den Kompressor aufstellen, in Betrieb nehmen oder Eingriffe
daran vornehmen.
NL
LEES HET INSTRUCTIEBOEKJE
Lees het instructieboekje aandachtig alvorens de compressor te plaatsen, inwerking te stellen of er werkzaamheden aan te
verrichten
DK
LÆS BRUGERVEJLEDNINGEN
Læs brugervejledningen grundigt før kompressoren tages i brug, eller der udføres indgreb på den.
ES
LEER EL MANUAL DE INSTRUCCIONES
Antes de colocar, poner en función o intervenir en el compresor, leer atentamente el manual de instrucciones.
PT
LER O MANUAL DE INSTRUÇÕES
Antes de colocar, pôr a funcionar ou intervir no compressor, ler atentamente este manual de instruções.
IT
RISCHIO DI SCOSSA ELE
T
TRICA
Attenzione: prima di effettuare ogni intervento sul compressore è obbligatorio disattivare l’alimentazione elettrica sulla macchi-
na stessa.
UK
RISK OF ELECTRIC SHOCK
Caution: before doing any work on the compressor it must be disconnected from the power supply.
FR
RISQUE D'ELECTROCUTION
Attention : avant d'effectuer toute intervention sur le compresseur, il est obligatoire de désactiver l'alimentation électrique de la
machine.
DE
GEFÄHRLICHE ELEKTRISCHE SPANNUNG
Vorsicht! Schalten Sie vor jedem Eingriff am Kompressor die Stromzufuhr aus.
NL
GEVAAR VOOR EEN ELEKTRISCHE SCHOK
Let op: schakel de stroomtoevoer op de machine beslist uit alvorens werkzaamheden op de compressor uit te voeren.
DK
FARE FOR ELEKTRISK STØD
Advarsel: det er påbudt at afbryde strømforsyningen til kompressoren, før der udføres nogen form for indgreb på den.
ES
RIESGO DE CHOQUE ELÉCTRICO
Atención: antes de efectuar cualquier tipo de intervención en el compresor, es obligatorio desconectar la alimentación eléctrica
de la máquina.
PT
PERIGO DE CHOQUE ELÉCTRICO
Atenção: antes de efectuar qualquer intervenção no compressor é obrigatório desligar a alimentação eléctrica da máquina.
3
IT
RISCHIO DI TEMPERAT
U
RE ELEVATE
Attenzione: nel compressore ci sono alcune parti che potrebbero raggiungere temperature elevate.
UK
RISK OF HIGH TEMPERATURES
Caution: the compressor contains some parts which might reach high temperatures.
FR
RISQUE DE TEMPERATURES ELEVEES
Attention : certaines parties du compresseur peuvent atteindre des températures élevées.
DE
GEFÄHRDUNG DURCH HEISSE OBERFLÄCHEN
Vorsicht! Im Kompressor befinden sich einige Teile, die sich stark erhitzen können.
NL
GEVAAR VOOR HOGE TEMPERATUREN
Let op: in de compressor kunnen enkele onderdelen hoge temperaturen bereiken.
DK
RISIKO FOR HØJE TEMPERATURER
Advarsel: der er dele i kompressoren, der kan opnå meget høje temperaturer.
ES
RIESGO DE TEMPERATURAS ELEVADAS
Atención: algunas partes del compresor pueden alcanzar temperaturas elevadas.
PT
PERIGO DE TEMPERATURAS ELEVADAS
Atenção: no compressor há algumas partes que poderão alcançar temperaturas elevadas.
IT
RISCHIO DI PARTENZA A
C
CIDENTALE
Attenzione: il compressore potrebbe ripartire in caso di black-out e successivo ripristino di tensione.
UK
RISK OF ACCIDENTAL START
-
UP
Attention, the compressor could start automatically after a power-cut if not switched off.
FR
RISQUE DE DEMARRAGE ACCIDENTEL
Attention : après une coupure de courant, au retour de l'alimentation, le compresseur risque de redémarrer.
DE
GEFÄHRDUNG DURCH PLÖTZLICHEN START
Vorsicht! Der Kompressor kann nach einen Stromausfall plötzlich neustarten.
NL
GEVAAR VOOR ONVOORZIEN OPSTARTEN
Let op: de compressor kan bij stroomuitval en daarop volgend herstel van de voedingsspanning opnieuw starten.
DK
RISIKO FOR UTILSIGTET IGANGSÆTNING
Advarsel: kompressoren kan starte igen i tilfælde af black-out ved efterfølgende genetablering af strømforsyningen.
ES
RIESGO DE
ARRANQUE ACCIDENTAL
Atención: el compresor puede volver a arrancar tras un corte de energía eléctrica y sucesivo restablecimiento de tensión.
PT
PERIGO DE ARRANQUE ACIDENTAL
Atenção: o compressor poderá começar a funcionar após uma falta de corrente quando essa voltar.
IT
4
5
IT
6
7
1
. SERBATOIO / TANK / RESERVOIR / KESSEL / TANK / BEHOLDER / DEPÓSITO /
DEPÓSITO / SÄILIÖ / TANK
2. MANOMETRO / PRESSURE GAUCE / MANOMETRE / MANOMETER / MANOMETER
/TRYKMÅLER / MANÓMETRO / MANÓMETRO / MANOMETRI / MANOMETER
3. PRESSOSTATO / PRESSURE SWITCH / PRESSOSTAT / DRUCKWÄCHTER /
DRUKREGELAAR / PRESSOSTAT / PRESOSTATO / BARÓSTATO / PAINEMITTARI /
TYCKMÄTARE
4. MANICO / HANDLE / POIGNEE / SCHLAUCH / HANDVAT / HANK / MANIJA / ASA /
KAHVA / HANDTAG
5. CARENATURA DI PROTEZIONE / GUARD / CARENAGE DE PROTECTION / SCHU-
TZVERKLEIDUNG / BESCHERMINGSSTROOMLIJNKAP / STRØMLINIEBEKLÆDNING
/ CARENADURA DE PROTECCIÓN / COBERTURA DE PROTECÇÃO / SUOJUS /
SKYDDSBEKLÄDNAD
6. GRUPPO COMPRESSORE / COMPRESSOR UNIT / GROUPE COMPRESSEUR /
KOMPRESSORAGGREGAT / COMPRESSOR GROEP / KOMPRESSORENHED /
GRUPO COMPRESOR / GRUPO COMPRESSOR / KOMPRESSORIYKSIKKÖ / KOM-
PRESSORGRUPP
7. FILTRI ARIA / AIR FILTER / FILTRE A AIR / LUFTFILTER / LUCHTFILTER / LUFTFIL-
TER / FILTRO DE AIRE / FILTRO AR / ILMASUODATIN / LUFTFILTER ASTA LIVELLO
OLIO / OIL LEVEL STICK / TIGE DE NIVEAU D’HUILE / ÖLSTAB / STOK OLIENIVEAU
/ OLIEMÅLEPIND / VARILLA NIVEL DE ACEITE / VARETA NÍVEL ÓLEO / ÖLJYTASO-
TANKO / OLJEMÄTSTICKA
8. USCITA ARIA COMPRESSA RIDOTTA / REDUCED COMPRESSED AIR OUTLET /
SORTIE RÉDUITE AIR COMPRIMÉ / REDUZIERTE DRUCKLUFTAUSGANG / UIT-
GANG SAMENGEPERSTE LUCHT VERMINDERD / UDGANG FOR REDUCERET
TRYKLUFT / SALIDA DEL AIRE COMPRIMIDO REDUCIDA / SAÍDA AR COMPRIMIDO
REDUZIDA / PAINEILMAN VÄHENNETTY ULOSMENO / REDUCERAD TRYCKLUF-
TSUTGÅNG
9. RIDUTTORE DI PRESSIONE / PRESSURE REDUCER / REDUCTEUR DE PRESSION
/ DRUCKMINDERER / DRUKREDUCTIEMACHINE /TRYKBEGRÆNSER / REDUCTOR
DE PRESIÓN / REDUTOR DE PRESSÃO / PAINEENVÄHENTÄJÄ / TYCKREDUCERA-
RE
10. USCITA ARIA COMPRESSA DIRETTA / DIRECT COMPRESSED AIR OUTLET / SOR-
TIE DIRECTE AIR COMPRIMÉ / DIREKTER DRUCKLUFTAUSGANG/ UITGANG SA-
MENGEPERSTE LUCHT DIRECT / UDGANG FOR DIREKTE LUFTTRYK / SALIDA DEL
AIRE COMPRIMIDO DIRECTA / SAÍDA AR COMPRIMIDO DIRECTA / PAINEILMAN
SUORA ULOSMENO / DIREKT TRYCKLUFTSUTGÅNG
11. RUOTA / WHEEL / ROUE / RAD / WIEL / HJUL / RUEDA / RODA / PYÖRÄ / HJUL
12. VALVOLA DI NON RITORNO / CHECK VALVE / VANNE DE NON-RETOUR /
RÜCKSCHLAGVENTIL / KLEP VOOR NIET TERUGKEER / KONTRAVENTIL/ VÁLVULA
DE ANTIRRETROCESO / VÁLVULA DE NÃO RETORNO / TAKAISKUVENTTIILI / VEN-
TIL UTAN ÅTERGÅNG.
13. SCARICO CONDENSA / CONDENSATE DRAIN / EVACUATION CONDENSATION /
AUSLASS KONDENSWASSER / AFVOER CONDENSWATER / TØMNING AF KON-
DENSVAND / DESAGÜE DEL CONDENSADO / PURGA DA CONDENSAÇÃO / KON-
DENSSIVEDEN TYHJENNYS / KONDENSVATTNETS AVLOPP.
1
. CARENATURA DI PROTEZIONE / GUARD / CARENAGE DE PROTECTION / SCHU-
TZVERKLEIDUNG / BESCHERMINGSSTROOMLIJNKAP / STRØMLI-
NIEBEKLÆDNING / CARENADURA DE PROTECCIÓN / COBERTURA DE PRO-
TECÇÃO / SUOJUS / SKYDDSBEKLÄDNAD
2. TAPPO SFIATO OLIO / BREATHER PLUG / BOUCHON DE PURGE / ENTLUFTUN
GSSTOPFEN / VENTILPROP / TAPON DE PURGA / TAMPAO DE PURGA / ILMA-
TULPPAAN / LUFTHAL
3. MANICO / HANDLE / POIGNEE / SCHLAUCH / HANDVAT / HANK / MANIJA / ASA /
KAHVA / HANDTAG
4. PRESSOSTATO / PRESSURE SWITCH / PRESSOSTAT / DRUCKWÄCHTER /
DRUKREGELAAR / PRESSOSTAT / PRESOSTATO / BARÓSTATO / PAINEMITTARI /
TYCKMÄTARE
5. RUOTA / WHEEL / ROUE / RAD / WIEL / HJUL / RUEDA / RODA / PYÖRÄ / HJUL
6. SERBATOIO / TANK / RESERVOIR / KESSEL / TANK / BEHOLDER / DEPÓSITO /
DEPÓSITO / SÄILIÖ / TANK
bar bar Hp/kW Min-1 dB(A)
8,5 8 0.65/0.5 1450 73
8,5 8 0.65/0.5 2850 75
8,5 8 0.75/0.65 1700/1450 73
8,5 8 1.5/1.1 3400/2850 75
8,5 8 2/1.5 3450/2850 79
8,5 8 2.5/1.8 2800 82
bar bar Hp/kW Min-1 dB(A)
10,5 10 1.5/1.1 1450 75
10,5 10 2/1.5 1700-1450 75
10,5 10 2.5/1.8 1450 75.5
10,5 10 3/2.2 2850 80
10,5 10 1.5/1.1 1450 75
IT
8
1. USCITA ARIA COMPRESSA DIRETTA / DIRECT COMPRESSED AIR OUTLET /
SORTIE DIRECTE AIR COMPRIMÉ / DIREKTER DRUCKLUFTAUSGANG / UITGANG
SAMENGEPERSTE LUCHT DIRECT / UDGANG FOR DIREKTE LUFTTRYK / SALIDA
DEL AIRE COMPRIMIDO DIRECTA / SAÍDA AR COMPRIMIDO DIRECTA / PAINEIL-
MAN SUORA ULOSMENO / DIREKT TRYCKLUFTSUTGÅNG
2. SERBATOIO / TANK / RESERVOIR / KESSEL / TANK / BEHOLDER / DEPÓSITO /
DEPÓSITO / SÄILIÖ / TANK
3. RIDUTTORE DI PRESSIONE / PRESSURE REDUCER / REDUCTEUR DE PRES-
SION / DRUCKMINDERER / DRUKREDUCTIEMACHINE / TRYKBEGRÆNSER / RE-
DUCTOR DE PRESIÓN / REDUTOR DE PRESSÃO / PAINEENVÄHENTÄJÄ / TY-
CKREDUCERARE
4. PARACINGHIA / BELT-GUARD / PROTECTION COURROIE / RIEMENSCHUTZ /
KETTINGBESCHERMER / BESKYTTELSESSKÆRM FOR REM / CUBRECORREA /
PROTECÇÃO DA CORREIA / HIHNASUOJUS / REMSKYDD
5. GRUPPO COMPRESSORE / COMPRESSOR UNIT / GROUPE COMPRESSEUR /
KOMPRESSORAGGREGAT / COMPRESSOR GROEP / KOMPRESSORENHED /
GRUPO COMPRESOR / GRUPO COMPRESSOR / KOMPRESSORIYKSIKKÖ /
KOMPRESSORGRUPP
6. MOTORE ELETTRICO / ELECTRIC MOTOR / MOTEUR ÉLECTRIQUE / ELEKTRO-
MOTOR / ELEKTRISCHE MOTOR / ELEKTRISK MOTOR / MOTOR ELÉCTRICO /
MOTOR ELÉCTRICO / SÄHKÖMOOTTORI / ELMOTOR
7. PRESSOSTATO / PRESSURE SWITCH / PRESSOSTAT / DRUCKWÄCHTER /
DRUKREGELAAR / PRESSOSTAT / PRESOSTATO / BARÓSTATO / PAINEMITTARI
/ TYCKMÄTARE
8. MANOMETRO / PRESSURE GAUCE / MANOMETRE / MANOMETER / MANOME-
TER / TRYKMÅLER / MANÓMETRO / MANÓMETRO / MANOMETRI / MANOMETER
9. RUOTA PIVOTTANTE / PIVOT WHEEL / ROUE PIVOTANTE / SCHWENKRAD /
DRAAIEND WIEL / HJULTAP / RUEDA PIVOTANTE / RODA GIRATÓRIA /
KÄÄNTÖPYÖRÄ / ROTERANDE HJUL
10. SCARICO CONDENSA / CONDENSATE DRAIN / EVACUATION CONDENSATION /
AUSLASS KONDENSWASSER / AFVOER CONDENSWATER / TØMNING AF KON-
DENSVAND / DESAGÜE DEL CONDENSADO / PURGA DA CONDENSAÇÃO /
KONDENSSIVEDEN TYHJENNYS / KONDENSVATTNETS AVLOPP
11. RUOTA / WHEEL / ROUE / RAD / WIEL / HJUL / RUEDA / RODA / PYÖRÄ / HJUL
12. VALVOLA DI RITEGNO / CHECK VALVE / VANNE DE RETENNE /
RÜCKSCHLAGVENTIL / TEGENHOUDKLEP / KONTRAVENTIL / VÁLVULA DE RE-
TENCIÓN / VÁLVULA DE RETENÇÃO / TAKAISKUVENTTIILI / STOPPVENTIL
1. MOTORE ELETTRICO / ELECTRIC MOTOR / MOTEUR ÉLECTRIQUE / ELEKTROMOTOR
/ ELEKTRISCHE MOTOR / ELEKTRISK MOTOR / MOTOR ELÉCTRICO / MOTOR
ELÉCTRICO / SÄHKÖMOOTTORI / ELMOTOR
2. PARACINGHIA / BELT-GUARD / PROTECTION COURROIE / RIEMENSCHUTZ / KET-
TINGBESCHERMER / BESKYTTELSESSKÆRM FOR REM / CUBRECORREA / PRO-
TECÇÃO DA CORREIA / HIHNASUOJUS / REMSKYDD
3. GRUPPO COMPRESSORE / COMPRESSOR UNIT / GROUPE COMPRESSEUR / KOM-
PRESSORAGGREGAT / COMPRESSOR GROEP / KOMPRESSORENHED / GRUPO
COMPRESOR / GRUPO COMPRESSOR / KOMPRESSORIYKSIKKÖ / KOMPRESSOR-
GRUPP
4. CENTRALIANA AVVIAMENTO YD / STARTING CONTROL UNIT YD / BOÎTIER DE DÉ-
MARRAGE Y? / STERNDREIECKANLASSER / CENTRALE OPSTARTEN UD / ELEKTRO-
NISK BETJENINGSPANEL FOR START YD / CENTRAL DE PUESTA EN MARCHA YD /
CAIXA DE ARRANQUE YD / KÄYNNISTYS VAIHDELAATIKKO YD / STARTCENTRAL YD
(1) Livello sonoro misurato in campo libero a 1 m di distanza ±3dB(A) alla massima pressione di utilizzo.
Acoustic pressure measured free-field at a distance of 1m: ±3dB(A) at maximum operating pressure.
Niveau sonore mesuré en champs libre à 1 m de distance ± 3dB(A) à la pression d’utilisation maximum.
Gemessene Schallpegel in einem Abstand von 1 m ±3dB(A) bei max
Geluidsniveau gemeten in vrij veld op 1 m afstand ±3
dB (A) bij de maximum gebruiksdruk
Gemessene Schallpegel in einem Abstand von 1 m ±3dB(A) bei max.
Nivel sonoro medido en campo libre a 1 m de distancia ±3dB (A) a la máxima presión de trabajo.
Nível sonoro medido em campo livre a 1 m de distância ±3dB(A) à pressão máxima de utilização.
(1)
bar bar Hp/kW Min-1 dB(A)
10,5 10
2-1.5 77
10,5 10
2-1.5 78
10,5 10
3-2.25 80
10,5 10
3-2.25 80
10,5 10
4-3 85
10,5 10
4-3 81
10,5 10
4-3 82
10,5 10
5.5-4.1 83
10,5 10
5.5-4.1 84
10,5 10
7.5-5.5 83
10,5 10 10-7.5 88
10,5 10
15 – 11 90
10,5 10 20 - 15 90
IT
INFORMAZIONI IMPORTANTI
Leggere attentamente tutte le istruzioni di funzionamento, i consigli per
la sicurezza e le avvertenze del manuale d’istruzioni.
La maggioranza degli incidenti con l’uso del compressore, sono dovuti
al non rispetto delle elementari regole di sicurezza. Identificando in
tempo le potenziali situazioni pericolose e osservando le regole di
sicurezza appropriate, si eviteranno gli incidenti.
Le regole fondamentali per la sicurezza sono elencate nella sezione
“SICUREZZA” di questo manuale e anche nella sezione che parla
dell’utilizzo e del mantenimento del compressore.
Le situazioni pericolose da evitare per prevenire tutti i rischi di lesioni
gravi o danni alla macchina sono segnalate nella sezione
“AVVERTENZE” sul compressore o nel manuale d’istruzione.
Non utilizzare mai il compressore in modo inappropriato, ma solo
come consigliato dal produttore, a meno che non si sia assolutamente
sicuri che non possa essere pericoloso ne per l’utilizzatore e per le
persone vicine.
SIGNIFICATO DELLE PAROLE DI SEGNALAZIONE
AVVERTENZE: indica una situazione potenzialmente pericolosa che,
se ignorata, può provocare morte o gravi danni.
PRECAUZIONI: indica una potenziale situazione pericolosa che, se
non evitata, potrebbe provocare minori o moderati danni alle persone e
alla macchina.
NOTA: sottolinea un’informazione essenziale
SICUREZZA
IMPORTANTI ISTRUZIONI PER L’UTILIZZO IN SICUREZZA DEL
COMPRESSORE
ATTENZIONE:
L’UTILIZZO INAPPROPRITATO E LA CATTIVA MANUTENZIONE DI
QUESTO COMPRESSORE POSSONO PROVOCARE LESIONI
FISICHE ALL’UTILIZZATORE. PER EVITARE QUESTI RISCHI SI
PREGA DI SEGUIRE ATTENTAMENTE LE SEGUENTI ISTRUZIONI
LEGGERE TUTTE LE ISTRUZIONI
1. NON TOCCARE LE PARTI IN MOVIMENTO
Non mettere mai le vostre mani, dita o altre parti del corpo vicino a
parti in movimento del compressore. Non inserire mai le dita o altri
oggetti all’interno della carenatura della ventola. Una simile azione
provoca il rischio di infortuni o shock elettrici.
2. NON USATE IL COMPRESSORE SENZA LE PROTEZIONI
MONTATE
Non usare mai il compressore senza che tutte le protezioni siano
perfettamente montate al proprio posto (es. carenature, paracinghia,
valvola di sicurezza) se la manutenzione o il servizio richiedono di
rimuovere queste protezioni assicuratevi che prima di utilizzare
nuovamente il compressore le protezioni siano ben fissate al posto
originale.
3. UTILIZZARE SEMPRE LE PROTEZIONI
Rischio di infortuni. Utilizzare sempre protezioni per gli occhi. Non
indirizzare l’aria compressa verso nessuna parte del corpo proprio o di
altri. Utilizzare protezioni per le orecchie in quanto il flusso dell’aria può
essere rumoroso.
4. PROTEGGI TE STESSO CONTRO GLI SHOCK ELETTRICI
Prevenire contatti accidentali del corpo con le parti metalliche del
compressore come tubi, serbatoio o parti di metallo collegate a terra.
Questo compressore deve essere collegato a terra in maniera
adeguata. Non esporre il compressore alla pioggia. Non usare mai il
compressore in presenza di acqua o di ambienti umidi. Non rimuovere
le carenature.
5. SCOLLEGARE IL COMPRESSORE
Scollegare il compressore dalla fonte elettrica e scaricare
completamente il serbatoio dalla pressione prima di effettuare
qualsiasi servizio, ispezione, manutenzione, pulizia rimpiazzo o
controllo di ogni parte.
6. PARTENZE ACCIDENTALI
Non trasportare il compressore mentre è collegato alla fonte elettrica o
quando il serbatoio è sotto pressione. Assicurarsi che l’interruttore del
pressostato sia nella posizione OFF prima di collegare il compressore
alla fonte elettrica.
7. STOCCARE IL COMPRESSORE IN MANIERA APPROPRIATA
Quando il compressore non è utilizzato deve essere tenuto in un locale
chiuso e secco al riparo dagli agenti atmosferici. Tenere lontano dai
bambini.
8. TENERE L’AREA DI LAVORO PULITA
Le aree disordinate aumentano il rischio di infortuni. Liberare l’area di
lavoro da utensili non necessari, detriti, suppellettili ecc.
9. CURA L’AMBIENTE DI LAVORO
Tenere la zona di lavoro pulita e ben ventilata. Utilizzare il
compressore su una superficie stabile durante tutto il funzionamento.
Rischio di incendio o esplosione. Non portare e usare il compressore o
altri apparecchi elettrici vicino all’area di soffiaggio. Non usare il
compressore in presenza di liquidi infiammabili o gas. Il compressore
può produrre scintille durante il funzionamento. Non usare il
compressore in situazioni dove si possono trovare vernici, benzine,
sostanze chimiche, adesivi e ogni altro materiale combustibile o
esplosivo. Non posizionare mai oggetti contro o sopra il compressore.
Al fine di evitare danneggiamenti al compressore, evitare che
l’apparecchio si inclinato più di 10° durante il funzionamento.
10. TENERE LONTANO I BAMBINI
Evitare che bambini o qualsiasi altra persona entri in contatto con il
cavo di alimentazione del compressore, tutti gli estranei devono essere
tenuti ad una distanza di sicurezza dalla zona di lavoro.
11. INDUMENTI DI LAVORO
Non indossare abiti voluminosi o gioielleria, questi potrebbero essere
catturati dalle parti in movimento. Indossare cuffie che coprano i capelli
se necessario.
12. NON ABUSARE DEL CAVO DI ALIMENTAZIONE
Non scollegare la spina di corrente tirando il cavo di alimentazione.
Tenere il cavo lontano dal calore, dall’olio e da superfici taglienti. Non
calpestare il cavo elettrico o schiacciarlo con pesi inadeguati.
13. MANTENERE IL COMPRESSORE CON CURA
Ispezionare il cavo di alimentazione periodicamente e se danneggiato
deve essere riparato o sostituito da un centro assistenza autorizzato.
Verificare l’aspetto esterno del compressore che non presenti
anomalie visive. Rivolgersi eventualmente al più vicino centro
assistenza.
14. PROLUNGHE ELETTRICHE PER UTILIZZO ESTERNO
Quando il compressore è usato esternamente utilizzare solamente
prolunghe elettriche destinate all’uso esterno e marcate per questo.
15. ATTENZIONE
Fate attenzione a cosa state facendo. Usate il buon senso comune.
Mai salire in piedi sul compressore. Non usate il compressore quando
siete stanchi. Il compressore non deve essere mai usato se siete sotto
l’effetto dell’alcool, droga o medicinali che possano indurre
sonnolenza.
16. CONTROLLARE PARTI DIFETTOSE O PERDITE DI ARIA
Prima di utilizzare nuovamente il compressore, se una protezione o
altre parti sono danneggiate devono essere controllate attentamente
per determinare se possono funzionare come previsto in sicurezza.
Controllare allineamento di parti in movimento, tubi, manomentri,
riduttori di pressione, connessioni pneumatiche e ogni altra parte che
può avere importanza nel funzionamento normale. Ogni parte
danneggiata deve essere propriamente riparata o rimpiazzata da un
servizio assistenza autorizzato o sostituito come indicato nel libretto
istruzioni. NON UTILIZZARE IL COMPRESSORE SE IL
PRESSOSTATO E’ DIFETTOSO.
17. USARE IL COMPRESSORE CORRETTAMENTE
Far funzionare il compressore conformemente alle istruzioni di questo
manuale. Non lasciare utilizzare il compressore ai bambini, alle
persone che non hanno famigliarità con il suo funzionamento.
18. VERIFICARE CHE OGNI VITE, BULLONE E COPERCHIO
SIANO SOLIDAMENTE FISSATI.
Verificare che ogni vite, bullone e copertura siano solidamente fissati.
Verificare periodicamente che siano ben stretti.
19. TENERE PULITA LA GRIGLIA DI ASPIRAZIONE
Tenere la griglia di ventilazione del motore pulita. Pulire regolarmente
questa griglia se l’ambiente di lavoro è molto sporco.
20. FARE FUNZIONARE IL COMPRESSORE ALLA TENSIONE
NOMINALE
Fare funzionare il compressore alla tensione specificata sulla targhetta
dei dati elettrici. Se il compressore è utilizzato a una tensione
superiore di quella nominale, il motore girerà più velocemente e si può
danneggiare l’unità bruciando il motore.
21. NON USARE MAI IL COMPRESSORE SE E’ DIFETTOSO
Se il compressore lavora emettendo strani rumori o eccessive
vibrazioni o appare difettoso, fermatelo immediatamente e verificate la
funzionalità o contattate il più vicino centro assistenza autorizzato.
22. NON PULIRE PARTI DI PLASTICA CON SOLVENTI
Solventi come benzina, diluenti, gasolio o altre sostanze che
contengono alcool possono danneggiare le parti di plastica, non
strofinare questi componenti sulle parti in plastica. Pulire
eventualmente queste parti con un panno morbido e acqua saponata o
liquidi appropriati.
23. USARE SOLO PARTI DI RICAMBIO ORIGINALI.
L’utilizzazione di parti di ricambio non originali provocano
l’annullamento della garanzia e un malfunzionamento del
compressore. I pezzi di ricambio originali sono disponibili presso i
distributori autorizzati.
IT
10
24. NON MODIFICARE IL COMPRESSORE
Non modificare il compressore. Non far funzionare il compressore a
velocità e pressioni maggiori di quelle prescritte dal costruttore.
Consultare un centro assistenza autorizzato per tutte le riparazioni.
Una modifica non autorizzata può diminuire le prestazioni del
compressore, ma può anche essere la causa di gravi incidenti per le
persone che non hanno la conoscenza tecnica necessaria per
effettuare delle modifiche.
25. SPEGNERE IL PRESSOSTATO QUANDO IL COMPRESSORE
NON E’ UTILIZZATO
Quando il compressore non è in uso, posizionare la manopola del
pressostato in posizione “0” (OFF), scollegare il compressore dalla
corrente e aprire il rubinetto di linea per scaricare l’aria compressa dal
serbatoio.
26. NON TOCCARE LE PARTI CALDE DEL COMPRESSORE
Per evitare bruciature, non toccare i tubi, il motore e tutte le altre parti
calde.
27. NON DIRIGERE IL GETTO D’ARIA DIRETTAMENTE SUL
CORPO
Per evitare rischi, non dirigere mai il getto d’aria su persone o animali.
Non usare mai l’aria compressa per respirare o per respiratori.
28. SCARICO CONDENSA DAL SERBATOIO
Rischio di scoppio. Si formerà acqua di condensa nel serbatoio. Se
non scaricata, l’acqua corroderà ed indebolirà il serbatoio causando un
rischio di rottura. Scaricare il serbatoio giornalmente oppure ogni 4 ore
di servizio. Per scaricare la condensa accumulata nel serbatoio, aprire
la valvola lentamente ed inclinare il compressore.
29. NON ARRESTARE IL COMPRESSORE TIRANDO IL CAVO DI
ALIMENTAZIONE
Questo potrebbe danneggiare il compressore. Utilizzare l’interruttore
“ON/OFF” del pressostato per arrestare il compressore.
30. CIRCUITO PNEUMATICO
Utilizzare tubi, utensili pneumatici raccomandati che sopportano una
pressione superiore o uguale alla massima pressione di esercizio
del compressore.
PEZZI DI RICAMBIO
Per le riparazioni, utilizzare unicamente pezzi di ricambio originali
identici ai pezzi sostituiti. Le riparazioni devono essere effettuate
unicamente da un centro assistenza autorizzato.
AVVERTENZE
ISTRUZIONI PER IL COLLEGAMENTO A TERRA
Questo compressore deve essere collegato a terra, mentre è in uso
per proteggere l’operatore da scosse elettriche. Il compressore
monofase è equipaggiato con un cavo bipolare più terra. Si
raccomanda di non smontare mai il compressore e nemmeno di
eseguire altri collegamenti nel pressostato. Qualsiasi riparazione deve
essere eseguita solamente dai centri assistenza autorizzati. Non
dimenticare mai che il filo di messa a terra è quello verde o
giallo/verde. Mai collegare questo filo verde a un terminale vivo.
PROLUNGA
Utilizzare solamente prolunga con spina e collegamento a terra, non
utilizzare prolunghe danneggiate o schiacciate. Assicurarsi che la
prolunga sia in buone condizioni. Quando si usa un cavo di prolunga
assicurarsi che la sezione del cavo sia sufficiente per portare la
corrente assorbita dal prodotto che collegherete. Una prolunga troppo
sottile può causare cadute di tensione e quindi una perdita di potenza
e un eccessivo riscaldamento dell’apparecchio. Il cavo di prolunga dei
compressori monofase deve avere una sezione proporzionata alla sua
lunghezza, vedi tabella. (tab. 1)
Tab.1 SEZIONE VALIDA PER LA LUNGHEZZA MASSIMA 20 mt
monofase
CV
Kw
220/230 V
[mm
2
]
110/120 V
[mm
2
]
0,75 - 1
0,65–0,7 1,5 2,5
1,5 1,1 2,5 4
2 1,5 2,5 4 – 6
2,5 - 3 1,8 – 2,2 4 /
Il cavo di prolunga dei compressori trifase deve avere una sezione
proporzionata alla sua lunghezza: vedi tabella (tab 2)
Tab. 2 SEZIONE VALIDA PER LA LUNGHEZZA MASSIMA 20 mt tri-
fase
CV
Kw
230 V
[mm
2
]
380/400V
2-3-4 1,5-2,2-3 2,5 1.5
5,5 4 4 2.5
7,5 5,5 6 2.5
10 7,5 10 4
15 11 16 10
20 15 25 16
AVVERTENZE:
Evitare tutti i rischi di scariche elettriche. Non utilizzare mai il
compressore con un cavo elettrico o una prolunga danneggiati.
Controllare regolarmente i cavi elettrici. Non usare mai il compressore
dentro o vicino all’acqua o in prossimità di un ambiente pericoloso
dove possono avvenire scariche elettriche.
CONSERVARE QUESTE ISTRUZIONI DI USO E MANUTENZIONE E
METTERLE A DISPOSIZIONE DELLE PERSONE CHE VOGLIONO
UTILIZZARE QUESTO APPARECCHIO!
UTILIZZO E MANTENIMENTO
NOTA: Le informazioni che troverete dentro questo manuale sono
state scritte per assistere l’operatore durante l’utilizzo e le operazioni di
mantenimento del compressore. Alcune illustrazioni di questo manuale
mostrano alcuni dettagli che possono essere differenti da quelli del
vostro compressore.
INSTALLAZIONE
Dopo aver tolto il compressore dall’imballo (fig. 1) ed averne accertato
la perfetta integrità, assicurandosi che non abbia subito danni durante
il trasporto, eseguire le seguenti operazioni. Montare le ruote e il
gommino sui serbatoi dove non sono montati seguendo le istruzioni
riportate in fig. 2. Nel caso di ruote gonfiabili, gonfiare le ruote fino a
una pressione massima di 1,6 bar Posizionare il compressore su una
superficie piana o al massimo con una inclinazione di 10° (fig. 3), in
luogo ben ventilato, al riparo da agenti atmosferici e non in ambienti
esplosivi.
Se il piano è inclinato e liscio, verificare che con il compressore in
funzionamento non si spost altrimenti bloccare le ruote con due cunei.
Se il piano è una mensola o il piano di uno scaffale, assicurarsi che
non possa cadere fissandolo nella maniera opportuna. Per ottenere
una buona ventilazione e un efficace raffreddamento è importante che
il compressore sia distante almeno 100 cm da qualsiasi parete (fig. 4).
I compressori montati su serbatoio a piedi fissi, non vanno fissati a
terra in maniera rigida, si consiglia il montaggio di n° 4 supporto antivi-
branti.
ISTRUZIONI D’USO
Fare attenzione a trasportare il compressore nella giusta maniera, non
capovolgerlo o sollevarlo con ganci o funi. (fig. 5 - 6).
Sostituire il tappo di plastica sul coperchio carter (fig. 7– 8) con l’asta
di livello olio (fig. 9) o con relativo tappo di sfiato (fig. 10) forniti unita-
mente al libretto istruzioni, controllare il livello olio facendo riferimento
allle tacche poste sull’asta (fig. 9) o alla spia livello olio (fig. 11).
COLLEGAMENTO ELETTRICO
I compressori monofase sono forniti completi di cavo elettrico e
spina di corrente bipolare + terra. È importante collegare il
compressore ad una presa di corrente dotata di collegamento a terra.
(fig. 12).
I compressori trifase (L1+L2+L3+PE) devono essere installati da un
tecnico specializzato. I compressori trifase sono forniti senza spina.
Collegare al cavo di alimentazione una spina elettrica con passacavo a
vite e collare di blocco (fig.13) facendo riferimento alla tabella sotto
riportata.
CV
Kw
Alimen. Volt/ph
Modello spina
2-3-4 1,5-2,2.3 220/230/3
16 A 3 poli+terra
380/400/3
16 A 3 poli+terra
5,5-7,5-10 4-5,5-7,5 220/230/3
32 A 3 poli+terra
380/400/3
32 A 3 poli+terra
15 - 20 11 - 15 220/230/3
63 A 3 poli+terra
380/400/3
32 A 3 poli+terra
NOTA: I compressori montati su serbatoio da 500 lt con potenza
CV7.5/ 55 kW e CV10/7.5 kW possono essere forniti con centralina di
avviamento stella/triangolo.
IT
11
Per l’installazione operare come segue:
Fissare la cassetta centralina a parete o a un supporto fisso, dotare la
stessa di un cavo alimentazione con spina elettrica e con sezione pro-
porzionata alla lunghezza.
Qualsiasi danno causato da errati collegamenti dell’alimentazione alla
linea, esclude automaticamente la garanzia delle parti elettriche. Onde
evitare errati collegamenti, è bene rivolgersi a un tecnico specializzato.
ATTENZIONE:
Non usare mai la presa di terra al posto del neutro. Il collegamento di
terra deve essere effettuato secondo le norme antinfortunistiche (EN
60204).La spina del cavo di alimentazione non deve essere usata co-
me interruttore, ma deve essere inserita in una presa di corrente co-
mandata da un interruttore differenziale adeguato (magneto termico).
AVVIAMENTO
Controllare che la tensione di rete corrisponda a quella indicata nella
targhetta dati elettrici (fig. 14), il campo di tolleranza ammesso deve
essere contenuto entro ± 5%. Al primo avviamento nei compressori
che funzionano con tensione trifase verificare l’esatto senso di rotazio-
ne della ventola di raffreddamento, mediante la freccia posta sul para-
cinghia o sulla carenatura. Ruotare o premere a seconda del tipo di
pressostato montato sull’apparecchio il pomello posto nella parte su-
periore in posizione “0” (fig. 15). Inserire la spina nella presa di corren-
te (fig. 12 - 13) e avviare il compressore portando il pomello del pres-
sostato in posizione “I”. Il funzionamento del compressore è comple-
tamente automatico, comandato dal pressostato che lo arresta quando
la pressione nel serbatoio raggiunge il valore massimo e lo fa ripartire
quando scende al valore minimo. Solitamente la differenza di pressio-
ne è di circa 2 bar (29 psi) tra il valore massimo e il valore minimo.
Es: il compressore si arresta quando raggiunge 8 bar (116 psi) (max
pressione di esercizio) e si riavvia automaticamente quando la pres-
sione all’interno del serbatoio è scesa a 6 bar (87 psi).
Dopo aver collegato il compressore alla linea elettrica fare una carica
alla massima pressione e verificare l’esatto funzionamento della mac-
china.
COMPRESSORI CON CENTRALINA DI AVVIAMENTO D (fig. 16)
Inserire la spina nella presa di corrente (fig. 13) portare il pressostato
in posizione “I” (ON) (fig. 17). Ruotare l’interruttore di alimentazione
generale “A” sulla centralina in posizione I la presenza di corrente è
segnalata dall’accensione della spia bianca “E”. Ruotare l’interruttore
“B” in posizione 1 per la partenza del compressore, l’accensione della
spia elettrovalvola “D” prima, e motore (C) dopo, segnalano il perfetto
funzionamento della macchina (fig. 18).
COMPRESSORI TANDEM CON CENTRALINA TEMPORIZZATA
(fig.17)
Inserire la spina nella presa di corrente (fi g. 13) portare il pressostato
in posizione “I” (ON). Ruotare l’interruttore di alimentazione generale
“A” sulla centralina in posizione 1, la presenza di corrente è segnalata
dall’accensione della spia bianca (E); ruotare l’interruttore “B” per la
partenza del compressore.
Pos. 1 funziona solo il pompante n. 1
Pos. 2 funziona solo il pompante n. 2
Pos. 3 funzionano i due pompanti contemporaneamente, con una
partenza differenziata.
Il funzionamento del compressore è completamente automatico
comandato dal pressostato che lo arresta quando la pressione del
serbatoio raggiunge il valore massimo e lo fa ripartire quando scende
al valore minimo.
NOTA: Il gruppo testa/cilindro/tubo di mandata, può raggiungere
temperature elevate, fare attenzione se si lavora in prossimità di questi
particolari, e non toccarli per evitare bruciature (fig. 18 - 19).
ATTENZIONE
Gli elettrocompressori devono essere collegati ad una presa di corren-
te protetta da interruttore differenziale adeguato (magneto termico).
Il motore dei compressori coassiali è dotato di una protezione termica
automatica posta all’interno dell’avvolgimento, la quale arresta il com-
pressore quando la temperatura del motore raggiunge valori troppo
elevati.Qualora dovesse intervenire, il compressore ripartirà automati-
camente dopo 10 - 15 minuti.
I motori dei compressori modello coassiale 2 cilindri sono dotati di una
protezione termica amperometrica a riarmo manuale, posta esterna-
mente sul coperchio morsettiera. Quando si verifica l’intervento della
termica, attendere alcuni minuti, poi ripristinare manualmente
l’interruttore termico (fig. 20).
I motori monofase dei compressori della serie traino cinghia sono dota-
ti di una protezione termica amperometrica a riarmo manuale, posta
sul coperchio morsettiera.
Quando si verifica l’intervento della termica attendere alcuni minuti, poi
ripristinare manualmente l’interuttore (fig. 20).
Nei compressori trifase traino cinghia la protezione è automatica.
Quando si verifica l’intervento della termica il pressostato si stacca,
posizione “0” (OFF), attendere alcuni minuti e riportare il pressostato in
posizione “I” (ON).
Nei compressori equipaggiati con centralina, la protezione termica è
all’interno della centralina.
Quando si verifica l’intervento della termica, operare come segue (fig.
22)
Portare gli interruttori sul coperchio della centralina in posizione
“0”,aprire il coperchio e premere il pulsante 1 della protezione termica.
Richiudere il coperchio centralina e riavviare il compressore seguendo
le operazioni già illustrate al paragrafo “Avviamento compressori con
centralina”
Gli stessi accorgimenti valgono per i compressori con alimentazione a
60 Hz.
REGOLAZIONE DELLA PRESSIONE DI LAVORO (
fig. 23)
Non è necessario utilizzare sempre la massima pressione di lavoro,
anzi il più delle volte l’utensile pneumatico utilizzato ha bisogno di me-
no pressione.
Nei compressori forniti di riduttore di pressione è necessario regolare
bene la pressione di lavoro. Sbloccare il pomello del riduttore di pres-
sione tirando verso l’alto, regolare la pressione al valore desiderato
ruotando il pomello in senso orario per aumentarla, antiorario per dimi-
nuirla, ottenuta la pressione ottimale bloccare il pomello premendo
verso il basso (fig. 23). Nei riduttori di pressione forniti senza manome-
tro, la pressione di taratura è visualizzabile sulla scala graduata posta
sul corpo del riduttore stesso. Nei riduttori di pressione dotati di ma-
nometro, la pressione di taratura è visualizzabile sul manometro stes-
so.
ATTENZIONE: Alcuni riduttori di pressione sono sprovvisti di push to
lock, quindi basta ruotare il pomello per regolarne la pressione.
MANUTENZIONE
Prima di effettuare qualsiasi intervento sul compressore accer-
tarsi che:
– L’interruttore generale di linea sia nella posizione “0”.
Il pressostato e gli interruttori sulla centralina siano disinseriti, posi-
zione “0”.
– Il serbatoio d’aria sia scarico da ogni pressione.
Ogni 50 ore di funzionamento è opportuno smontare il filtro di aspira-
zione e pulire l’elemento filtrante soffiando con aria compressa (fig.
24).
È consigliabile sostituire l’elemento filtrante almeno una volta all’anno
se il compressore lavora in ambiente pulito; più frequentemente se
l’ambiente nel quale è posizionato il compressore risulta polveroso.
Il compressore genera acqua di condensa che si accumula nel serba-
toio.
È necessario scaricare la condensa dal serbatoio almeno una volta
alla settimana aprendo il rubinetto di scarico (fig. 26) sotto il serbatoio.
Fare attenzione se c’è presenza di aria compressa all’interno della
bombola, l’acqua potrebbe uscire con molta spinta. Pressione consi-
gliata 1-2 bar max. La condensa del compressore lubrificato non deve
essere gettata in fogna o dispersa nell’ambiente poiché contiene olio.
CAMBIO - RABBOCCO OLIO
I
l compressore è fornito con olio sintetico. Entro le prime 100 ore di
lavoro è consigliabile sostituire completamente l’olio del pompante.
Svitare il tappo di scarico olio sul coperchio carter, fare uscire tutto
l’olio, riavvitare il tappo (fig. 27 - 28). Introdurre l’olio dal foro superiore
del coperchio carter (fig. 29 - 30) fino a raggiungere il livello indicato
sull’asta (fig. 9) o sulla spia (fig. 11) Introdurre l’olio del foro superiore
della testa (fig. 30) nei gruppi a cinghia predisposti per il rabbocco in
quella zona.
Ogni settimana controllare il livello dell’olio del pompante (fig. 11) e se
necessario rabboccarlo. Per un funzionamento con temperatura am-
biente da -5°C a +40°C utilizzare olio sintetico. L’olio sintetico offre il
vantaggio di non perdere le proprie caratteristiche sia nel periodo in-
vernale che estivo.
L’olio usato non deve essere gettato in fogna o disperso nell’ambiente.
PER LA SOSTITUZIONE DELL’OLIO ATTENERSI ALLA TABELLA:
TIPO OLIO ORE DI FUNZIONAMENTO
Olio Sintetico..............................................500
Olio minerale…………………………………100
IT
12
COME INTERVENIRE NELLE PICCOLE ANOMALIE
Perdite d’aria dalla valvola sotto il pressostato
Questo inconveniente dipende da una imperfetta tenuta della valvola
di ritegno, intervenire nel seguente modo (fig. 31).
– Svuotare completamente il serbatoio dalla pressione
– Svitare la testa esagonale della valvola (A)
– Pulire accuratamente sia il dischetto di gomma (B) sia la sua sede
– Rimontare il tutto accuratamente
Perdite d’aria
Possono dipendere dalla cattiva tenuta di qualche raccordo, controlla-
re tutti i raccordi bagnandoli con acqua saponata.
Il compressore gira però non carica
Compressori coassiali: (fig. 32)
- Può essere dovuto alla rottura delle valvole (C1 C2) oppure di una
guarnizione (B1 B2) intervenire sostituendo il particolare danneggia-
to.
Compressori traino a cinghia: (fig. 33)
- può essere dovuto alla rottura delle valvole F1 e F2 oppure di una
guarnizione (D1 – D2), intervenire sostituendo il particolare danneggia-
to
Il compressore non parte
Se il compressore ha difficoltà a partire, controllare:
- Che la tensione di rete corrisponda a quella nella targhetta dati. (fig.
14)
- Che non vengano utilizzate prolunghe elettriche di sezione o lun-
ghezza non adeguata.
- Che l’ambiente di lavoro non sia troppo freddo. (al di sotto dei 0°C)
- Nel caso della serie coassiali 2 cilidri - traino cinghia che non sia in-
tervenuto il protettore termico (fig. 20).
- Che ci sia olio nel carter per garantire lubrificazione. (fig. 11)
- Che la rete elettrica sia alimentata (presa ben collegata, megneto-
termico, fusibili integri)
Il compressore non si arresta
- Se il compressore non si arresta al raggiungimento della massima
pressione entrerà in funzione la valvola di sicurezza del serbatoio. È
necessario contattare il più vicino centro assistenza autorizzato per la
riparazione.
ATTENZIONE
- Evitare assolutamente di svitare qualsiasi connessione con il serba-
toio in pressione, accertarsi sempre che il serbatoio sia scarico.
- È vietato effettuare fori, saldature o deformare volutamente il serba-
toio dell’aria compressa.
- Non eseguire operazioni sul compressore senza prima avere disinse-
rito la spina dalla presa di corrente.
- Temperatura ambiente consigliata di funzionamento 0°C +35°C.
- Non indirizzare getti d’acqua o liquidi infiammabili sul compressore.
- Non posizionare oggetti infiammabili vicino al compressore.
- Durante soste di utilizzo portare il pressostato in posizione “0” (OFF)
(spento).
- Non indirizzare mai il getto d’aria verso persone o animali. (fig. 34)
- Non trasportare il compressore con il serbatoio in pressione.
- Fare attenzione che alcune parti del compressore come testa e tubi
di mandata possono raggiungere temperature elevate. Non toccare
questi componenti per evitare bruciature. (fig. 18 - 19)
- Trasportare il compressore sollevandolo o tirandolo per le apposite
impugnature o manici. (fig. 4 - 6)
- Bambini e animali devono essere tenuti lontani dall’area di funziona-
mento della macchina.
- Se usate il compressore per verniciare:
a) Non operate in ambienti chiusi o in prossimità di fiamme libere
b) Assicuratevi che l’ambiente dove operate abbia un adeguato ricam-
bio d’aria
c) Proteggete il naso e la bocca con un’apposita mascherina. (fig. 35)
- Se il cavo elettrico o la spina sono danneggiati non usare il compres-
sore e rivolgersi al centro assistenza autorizzato per la sua sostituzio-
ne con un componente originale.
- Se viene posto su uno scaffale o un piano più alto del pavimento de-
ve essere fissato per evitare una possibile caduta durante il suo fun-
zionamento.
- Non inserire oggetti e mani all’interno delle griglie di protezione per
evitare danni fisici e al compressore. (fig. 36)
- Evitare di usare il compressore come oggetto contundente verso per-
sone cose o animali per evitare gravi danni.
- Terminato l’utilizzo del compressore disinserire sempre la spina dalla
presa di corrente.
N.B. I compressori bi-stadio possono essere forniti a richiesta per un
utilizzo fino a 14 bar. In questo caso:
pressione massima di esercizio 14.75 bar
pressione massima di utilizzo 14 bar
NOTA: Per il mercato europeo i serbatoi dei compressori sono costruiti
secondo la Direttiva 2009/105.
Per il mercato europeo i compressori sono costruiti conformi alla
Direttiva 2006/42 EC.
CONSIGLI UTILI PER UN BUON FUNZIONAMENTO
Per un buon funzionamento della macchina a pieno carico continuativo
alla massima pressione di esercizio assicurarsi che la temperatura
dell’ambiente di lavoro in ambiente chiuso non superi i +25°C.
Si suggerisce di utilizzare il compressore con un servizio massimo al
70% in un’ora a pieno carico, questo per permettere un buon funzio-
namento del prodotto nel tempo.
IMMAGAZZINAMENTO COMPRESSORE IMBALLATO
E
DISIMBALLATO
Per tutto il periodo che il compressore rimane inattivo prima del disim-
ballo immagazzinarlo in luogo asciutto con una temperatura compresa
fra i + 5°C e + 45°C e in posizione tale da evitarne il contatto con
agenti atmosferici.
Per tutto il periodo che il compressore rimane inattivo dopo essere sta-
to disimballato, in attesa della messa in funzione o per interruzioni di
produzione, proteggerlo con teli per evitare che la polvere vada a de-
positarsi sui meccanismi.
È necessario, se il compressore rimane inattivo per lunghi periodi, di
sostituire l’olio e di verificare il funzionamento.
COLLEGAMENTI PNEUMATICI
Assicurarsi di utilizzare sempre tubi pneumatici per aria compressa
che abbiano caratteristiche di massima pressione adeguate a quelle
del compressore. Non cercare di riparare il tubo se difettoso.
CI RISERVIAMO DI APPORTARE QUALSIASI MODIFICA SENZA
PREAVVISO OVE NECESSARIO.
GB
13
IMPORTANT INFORMATION
Read and understand all of the operating instructions, safety precau-
tions and warnings in the Instruction Manual before operating or
maintaining this compressor.
Most accidents that result from compressor operation and mainte-
nance are caused by the failure to observe basic safety rules or pre-
cautions.
An accident can often be avoided by recognizing a potentially haz-
ardous situation before it occurs, and by observing appropriate safety
procedures.
Basic safety precautions are outlined in the “SAFETY” section of this
Instruction Manual nad in the sections which contain the operation
and maintenance instructions.
Hazards that must be avoided to prevent bodily injury or machine
damage are identified by WARNINGS on the compressor and in this
Instruction Manual.
Never use this compressor in a manner that has not been specifically
recommended by manufacturer, unless you first confirm that the
planned use will be safe for you and others.
MEANINGS OF SIGNAL WORDS
WARNING: indicates a potentially hazardous situations which, if ig-
nored, could result in serious personal injury.
CAUTION: indicates a hazardous situations which, if ignored, couls
result moderate personal injury, or could cause machine damage.
NOTE: emphasizes essential information
SAFETY
IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COM-
PRESSOR.
WARNING:
DEATH OR SERIOUS BODILY INJURY COULD RESULT FROM
IMPROPER OR UNSAFE USE OF COMPRESSOR. TO AVOID
THESE RISKS, FOLLOW THESE BASIC SAFETY INSTRUCTIONS.
READ ALL INSTRUCTIONS
1. NEVER TOUCH MOVING PARTS
Never place your hands, fingers or other body parts near the com-
pressor’s moving parts.
2. NEVER OPERATE WITHOUT ALL GUARDS IN PLACE
Never operate this compressor without all guards or safety features in
place and in proper working order. If maintenance or servicing re-
quires the removal of a guard or safety features, be sure to replace
the guards or safety feature before resuming operation of the com-
pressor.
3. ALWAYS WEAR EYE PROTECTION
Always wear safety goggles or equivalent eye protection.
Compressed air must never be aimed at anyone or any part of the
body.
4. PROTECT YOURSELF AGAINST ELECTRIC SHOCK
Prevent body contact with grounded surfaces such as pipes, radia-
tors, ranges and refrigeration enclosures. Never operate the com-
pressor in damp or wet locations.
5. DISCONNECT THE COMPRESSOR
Always disconnect the compressor from the power source and re-
move the compressed air from the air tank before servicing, inspect-
ing, maintaining, cleaning, replacing or checking any parts.
6. AVOID UNINTENTIONAL STARTING
Do not carry the compressor while it is connected to its power source
or when the air tank is filled with compressed air. Be sure the knob of
the pressure switch in the “OFF” position before connecting the com-
pressor to its power source.
7. STORE COMPRESSOR PROPERLY
When not in use, the compressor should be stored in dry place.
Keep out of reach of children. Lock-out the storage area.
8. KEEP WORK AREA CLEAN
Cluttered areas invite injurues. Clear all work areas of unnecessary
tools, debris, furniture etc…
9. KEEP CHILDREN AWAY
Do not let visitors contact compressor extension cord. Alla visitors
should be kept safely away from work area.
10. DRESS PROPERLY
Do not wear loose clothing or jewerly. They can be caught in moving
parts. Wear protective hair covering to contain long hair.
11. DON’T ABUSE CORD
Never yank it to disconnect from receptable. Keep cord from heat, oil
and sharp edges.
12. MAINTAIN COMPRESSOR WITH CARE
Follow instructions for lubricating. Inspect cords periodically and if
damaged, have repaired by authorized service facility.
Inspect extension cords periodically and replace if damaged.
13. OUTDOOR USE EXTENSION CORDS
When compressor in used outdoors, use only extension cords in-
tended for use outdoors and so marked.
14. STAY ALERT
Watch what you are doing. Use common sense. Do not operate
compressor when you are tired.
Compressor should never be used by you if you are under the influ-
ence of alcohol, drugs or medication that makes you drowsy.
15. CHECK DAMAGED PARTS AND AIR LEAK
Before further use of the compressor, a guard or other part is dam-
aged should be carefully checked to determine that it will operate
properly and perform its intended function.
Check for alignment of moving parts, binding of moving parts, break-
age of parts, mounting, air leak, and any other conditions that may
affect its operation.
A guard or other part that is damaged should be properly repaired or
replaced by an authorized service center unless otherwise indicated
elsewhere in this Instruction Manual. Have defective pressure
switches replaced by authorized service center. Do not use compres-
sor if switch does not turn it on and off.
16. HANDLE COMPRESSOR CORRECTLY
Operate the compressor according to the instructions provided here-
in. Never allow the compressor to be operated by children, individuals
unfamiliar with its operation or unauthorized personnel.
17. KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY IN
PLACE
Keep all screws, bolts, and plates tightly mounted.
Check their condtions periodically.
18. KEEP MOTOR AIR VENT CLEAN
The motor air vent must be kept clean so that air can freely flow at all
times. Check for dust build-up frequently.
19. OPERATE COMPRESSOR AT THE RATED VOLTAGE
Operate the compressor at voltages specified on their nameplates. If
using the compressor at a higher voltage than the rated voltage, it will
result in abnormally fast motor revolution and mey damage the unit
and burn out the motor.
20. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR
OPERATING ABNORMALLY
If the compressor appears to be operating unusually, making strange
noises, or otherwise appears defective, stop using it immediately and
arrange for repairs by a authorized service center.
21. DO NOT WIPE PLASTIC PARTS WITH SOLVENT
Solvents such as gasoline, thinner, benzine, carbon tetrachloride,
and alcohol may damage and crack plastic parts. Do not wipe them
with such solvents. Wipe plastic parts with a soft cloth lightly damp-
ened with soapy water and dry thoroughly.
22. USE ONLY GENUINE REPLACEMENT PARTS
Replacement parts not original may void your warranty and can lead
to malfunction and resulting injuries. Genuine parts are available from
your dealer.
23. DO NOT MODIFY THE COMPRESSOR
Do not modify the compressor. Always contact the authorized service
center any repairs. Unauthorized modification may not only impair the
compressor performance but may also result in accident or injury to
repair personnel who do not have the required knowledge and tech-
nical expertise to perform the repair operations correctly.
24. TURN OFF THE PRESSURE SWITCH WHEN THE COMPRES-
SOR IS NOT USED
When the compressor is not used, turn the knob of the pressure
switch OFF, disconnect it from the power source and open the drain
cock to discharge the compressed air from the air tank.
25. NEVER TOUCH HOT SURFACE
To reduce the risk of burns, do not touch tubes, heads, cylinder and
motors.
26. DO NOT DIRECT AIR STREAM AT BODY
Risk of injury, do not direct air stream at persons or animals.
27. DRAIN TANK
Drain tank daily or after 4 hours of use.
Open drain fitting and tilt compressor to empty accumulated water.
28. DO NOT STOP COMPRESSOR BY PULLING OUT THE PLUG
Use the “AUTO/OFF” knob of pressure switch.
29. USE ONLY RECOMMENDED AIR HANDLING PARTS
ACCEPTABLE FOR PRESSURE NOT LESS THAN 125 PSI (8.6
BAR)
GB
14
Risk of bursting. Use only recommended air handling parts accepta-
ble for pressures not less than 125 psi (8.6 bar).
REPLACEMENT PARTS
When servicing use only identical replacement parts.
Repairs should be conducted only by authorized service center.
SAFETY
GROUNDING INSTRUCTIONS
This compressor should be grounded while in use to protect the op-
erator from electric shock. The compressor is equipped with a three-
conductor cord and three-prong grounding type plug to fit the proper
grounding type receptacle.
The green (or green and yellow) conductor in the cord is the ground-
ing wire. Never connect the green (or green and yellow) wire to a live
terminal. If your units is for use on less than 150 volts, it has a plug
that looks like that shown in sketch (A) in figure on the right. An
adapter, see sketches (B) and (C), is available for connecting sketch
(A) type plugs to twoprong receptacles. The green-colored rigid ear,
lug, or the like extending from the adapter must be connected to a
permanent ground, such as a properly grounded outlet box.
NOTE: the grounding adaptor, sketch (C), is prohibited in Canada by
Canadian Electrical Code Part.1. Therefore, the instructions for its
use are not applicable in Canada.
EXTENSION CORD
Use only three-extension cords that have three-prong grounding type
plugs and three-pole receptables that accept the compressor’s plug.
Replace or repair damaged cord. Make sure your extension cord is in
good condition. When using an extension cord, be sure to use one
heavy enough to carry the current your product will draw. An under-
sized cord will cause a drop in line voltage resulting in loss of power
and overheating.
Table shows the correct size to use depending on cord lenght and
name plate ampere rating. If in doubt, use the next heavier gage. The
smaller the gage number, the heavier the cord.
Tab.1 SECTION VALID FOR A MAX LENGHT OF 20 mt single-
phase
HP
Kw
220/230 V
[mm
2
]
110/120 V
[mm
2
]
0,75 - 1
0,65–0,7 1,5 2,5
1,5 1,1 2,5 4
2 1,5 2,5 4 – 6
2,5 - 3 1,8 – 2,2 4 /
The diameter of the extension cable of the 3-phase compressors
must be in proportion to its length: see table (tab 2)
Tab. 2 SECTION VALID FOR A MAX LENGHT OF 20 mt three-
phase
HP
Kw
230 V
[mm
2
]
380/400V
2-3-4 1,5-2,2-3 2,5 1.5
5,5 4 4 2.5
7,5 5,5 6 2.5
10 7,5 10 4
15 11 16 10
20 15 25 16
WARNING
Avoid electrical shock hazard. Never use this compressor with a
damaged or frayed electrical cord or extension cord. Inspect all elec-
trical cords regularly. Never use in near water or in any environment
where electric shock is possible
SAVE THESE INSTRUCTION AND MAKE THEM AVAILABLE TO
OTHER USERS OF THIS TOOL!
OPERATION AND MAINTENANCE
NOTE: The information contained in this Instruction Manual is de-
signed to assist you in the safe operation and maintenance of the
compressor.
Some illustrations in this Instruction Manual may show details or at-
tachments that differ from those on your own compressor.
INSTALLATION
Remove the compressor from its packing (fig.1), makes sure it is in
perfect condition, checking if it was damaged during transport, and
carry out the following operations. Fit the wheels and rubber tab on
the tanks on which they are not already fitted, observing the instruc-
tions in fig.2.
In case of infiatable wheels, the maximum inflation pressure must be
of 1,6 bar (24 psi). Position the compressor on a flat surface or with a
maximum permissible inclination of 10° (fig. 3), in a well aired place,
protected against atmospheric agents and not in a place subject to
explosion hazard. If the surface is inclined and smooth, check if the
compressor moves while in operation if it does, secure the wheels
with two wedges. If the surface is a bracket or a shelf top, make sure
it cannot fall, securing it in a suitable way. To ensure good ventilation
and efficient cooling, the compressor’s belt guard must be at least
100 cm from any wall (fig. 4). Compressors fitted on the tank, with
fixed feet, should not be rigidly secured to the ground. In this case,
we advise you to fit 4 anti-vibration supports.
USE INSTRUCTIONS
Take care to transport the compressor correctly, do not overturn it
or lift it with hooks or ropes (fig. 5 - 6)
– Replace the plastic plug on the guard cover (fig. 7 - 8) with the oil
level stick (fig. 9) or with the relevant breather plug (fig. 10), supplied
with the instructions booklet. Check oil level, consulting the reference
marks on the stick (fig. 9) or the oil level inspection window (fig. 11).
ELECTRICAL CONNECTION
Single-phase compressors are supplied with an electrical cable and
a two-pole + earth plug. The compressor must be connected to a
grounded power socket (fig.12).
Three-phase compressors (L1+L2+L3+PE) must be installed by a
specialised technician. Three-phase compressors are supplied with-
out a plug. Connect a plug, with screw-on grommet and securing col-
lar (fig.13), to the cable, consulting the table below.
Hp
Kw
Power supply volt/ph
Plug model
2-3-4 1,5-2,2.3 220/230/3
16 A 3 pole+ground
380/400/3
16 A 3 pole+ground
5,5-7,5-10 4-5,5-7,5 220/230/3
32 A 3 pole+ground
380/400/3
32 A 3 pole+ground
15 - 20 11 - 15 220/230/3
63 A
3 pole+ground
380/400/3
32 A 3 pole+ground
NOTE: Compressors installed on the 500 lt tank, with capacity of
HP7.5/ 55 kW and HP10/7.5 kW can be supplied a star/triangle start-
ing control unit.
Installation instructions:
– Secure the control unit box on a wall or on a fixed support, and pro-
vide it with a power cable with plug, of a diameter in proportion to its
length.
Any damage caused by incorrect connections of the power line to
the mains, automatically excludes warranty of electrical parts. To
avoid connection errors, we advise you to contact a specialised tech-
nician.
IMPORTANT:
Never use the ground socket instead of the neutral wire. The ground
connection must be made to meet safety standards(EN 60204).
The plug of the power cable must not be used as a switch, but must
be fitted in a power socket controlled by a suitable differential switch
(thermalbreaker).
STARTING
Check that the mains power matches that indicated on the electrical
data-plate (fig.14) the permissible tolerance range is +/-5%. When
first starting compressors operating on 3-phase voltage, check the
rotation direction of the cooling fan by comparing it with the direction
of the arrow on the belt guard or on the protective housing.
Turn or press into position “0 (according to the type of pressure
switch fitted on the appliance) the knob located on the upper section
GB
15
(fig. 15). Fit the plug in the power socket (fig. 12 - 13) and start the
compressor, turning the pressure switch knob into position “I”. The
compressor is fully automatic, and is controlled by the pressure
switch which stops it when tank pressure reaches maximum value
and restarts it when it falls to minimum value. The pressure difference
between maximum and minimum values is usually about 2 bar (29
psi).
E.g.: the compressor stops when it reaches 8 bar (116 psi maxi-
mum operating pressure) and restarts automatically when the pres-
sure inside the tank drops to 6 bar (87 psi).
After connecting the compressor to the power line, load it to maxi-
mum pressure and check exactly how the machine is operating.
COMPRESSORS WITH D STARTING CONTROL UNIT (fig. 16)
Fit the plug in the power socket (fig. 13) and turn the pressure switch
to position “I” (ON) (fig. 17). Turn the master power switch “A” on the
control unit to position I power On is signalled by white indicator-
light “E” going on. Turn switch “B” to position 1 to start the compres-
sor. If the solenoid-valve indicator-light “D” and the motor (C) indica-
tor-light (C) go on in that order, this means the machine is operating
perfectly (fig. 18).
TANDEM COMPRESSORS WITH TIMED CONTROL UNIT (fi g. 17)
Fit the plug in the power socket (fi g. 13) and turn the pressure switch
to position “I” (ON). Turn the master power switch “A” on the control
unit to position I – power On is signalled by white indicator-light “E”
going on.
Turn switch “B” to start the compressor.
Pos. 1 pumping element n. 1 only is operating
Pos. 2 pumping element n. 2 only is operating
Pos. 3 both pumping elements are operating simultaneously, at stag-
gered starting times.
The compressor is fully automatic, and is controlled by the pressure
switch which stops it when tank pressure reaches maximum value
and restarts it when it falls to minimum value.
IMPORTANT
The electro-compressors must be connected to a power socket pro-
tected by a suitable differential switch (thermal-breaker). The motor of
coaxial compressors is equipped with an automatic thermal breaker
located inside the winding this stops the compressor when motor
temperature reaches excessively high values.
If the breaker is tripped, the compressors restarts automatically af-
ter 10 to 15 minutes. The motors of compressor models coaxial dou-
ble cylinders are supplied with a manually resetting automatic am-
perometric thermal-breaker, located outside the terminal board cover.
When the breaker is tripped, wait for a few minutes and then reset
the breaker manually (fig. 20).
The motors of the belt drive series compressors are supplied with a
manually resetting amperometric thermal-breaker, located on the
terminal board cover. When the breaker is tripped, wait for a few
minutes and then reset the breaker manually (fig. 20).
The safety davice is automatic in three-phase and silent compres-
sors.
When the thermal-breaker is tripped, the pressure switch is released
to “0” (OFF) position.
Wait for a few minutes and return the pressure switch to “I” (ON) posi-
tion. For compressors supplied with a control unit, the thermal-
breaker is installed inside the control unit. When the thermal-breaker
is tripped, observe the following procedure (fig. 22):
Turn the switches on the control unit cover to position “0”, open the
cover and press push-button 1 of the thermal-breaker. Close the cov-
er of the control unit and restart the compressor, observing the opera-
tions described in the paragraph “Starting compressors with control
unit”.
The same instructions apply to compressors powered at 60 Hz.
ADJUSTING OPERATING PRESSURE (fig. 23)
You do not have to use the maximum operating pressure at all times.
On the contrary, the pneumatic tool being used often requires less
pressure. On compressors supplied with a pressure reducer, operat-
ing pressure must be correctly adjusted.
Release the pressure reducer knob by pulling it up, adjust pressure to
the required value by turning the knob clockwise to increase pressure
and anti-clockwise to reduce it. When you have obtained optimum
pressure, lock the knob by pressing it downward (fig. 23). For pres-
sure reducers equipped without a pressure gauge, the set pressure
can be seen on the graduated scale located on the reducer body.
On pressure reducers equipped with a pressure gauge, pressure can
be seen on the gauge itself.
WARNING: Some pressure regulators do not have "push to lock",
therefore simply turn the knob to adjust the pressure.
MAINTENANCE
Before attempting any maintenance jobs on the compressor, make
sure of the following:
– Master power switch in position “0”.
– Pressure switch and the control unit switches all off, in position “0”.
– No pressure in the air tank.
Every 50 hours of duty: we advise you to dismantle the suction filter
and clean the filtering element by blowing compressed air on it (fig.
24).
You are recommended to replace the filter element at least once if
the compressor operates in a clean environment, but more frequently
if in a dusty environment.
The compressor generates condensate water which accumulates in
the tank.
The condensate in the tank must be drained at least once a week, by
opening the drain tap (fig. 26) under the tank.
Take care if there is compressed air inside the cylinder, and water
could flow out with considerable force. Recommended pressure: 1
2 bar max.
Condensate of compressors that are oil lubricated must not be
drained into the sewer or dispersed in the environment as it contains
oil.
OIL CHANGES – TOPPING UP WITH OIL
The compressor is filled with synthetic oil.
We recommend a full change of oil in the pumping element within the
first 100 hours of duty.
Unscrew the oil drain plug on the housing cover, allow all the oil to
flow out, and re-screw the plug (fig. 27 - 28).
Pour oil into the upper hole of the housing cover (fig. 29 - 30) until it
reaches the level indicated on the stick (fig. 9) or indicator (fig. 11)
Pour oil into the upper hole of the head (fig. 30) in belt assisted units
designed for topping up in that area.
Once a week: check oil level of the pumping element (fig. 11) and
see if it needs topping up.
For operation at ambient temperature in the range -5°C to +40°C, use
synthetic oil. The advantage of this oil is that is does not lose its
characteristics either in winter or summer.
Do not drain used oil into the sewer or dispose of it in the environ-
ment.
OBSERVE THIS TABLE FOR OIL CHANGES
TYPE OF OIL HOURS OF DUTY
Synthetic Oil...................................500
Mineral Oil…………………………….100
WHAT TO DO IF SMALL MALFUNCTIONS OCCUR
Loss of air in valve under pressure switch
This trouble depends on poor tightness of the check valve take the
following action (fig. 31):
– Discharge all pressure from the tank
- Unscrew the hexagon-head of the valve (A)
- Carefully clean both the rubber disk (B) and its seat.
- Refit all parts accurately.
Air losses
These can be caused by poor tightness of a union – check all unions,
wetting them with soapy water.
Compressor turns but does not load
Coaxial compressors: (fig. 32)
- this may be due to failure of the valves (C1 – C2) or of a seal (B1 –
B2): replace the damaged part.
Pulley drive compressors: (fig. 33)
- this may be due to failure of the valves F1 and F2 or of a seal (D1 –
D2): replace the damaged part.
Compressor no starting
If the compressor has trouble starting, check the following :
- Does mains power match that of the data-plate? (fig. 14)
- Are power cable extensions of adequate diameter or length?
- Is the work environment too cold? (under 0°C)
GB
16
- For belt drive series the thermal-breaker tripped (fig. 20).
- Is there oil in the housing to ensure lubrication? (fig. 11)
- Is power supplied to the electrical line? (sockets well connected,
thermal- breaker, fuses in good condition).
Compressor not stopping
- If the compressor does not stop when maximum pressure is
reached, the tank safety valve comes into operation. To repair the
valve, contact your nearest service centre.
IMPORTANT
- Do not on any account unscrew any connection while the tank is
pressurised – always check if the tank is pressure free.
- Do not drill holes, weld or purposely deform the compressed air
tank.
- Do not do any jobs on the compressor unless you have disconnect-
ed the power plug.
- Temperature in operating ambient: 0°C +35°C.
- Do not aim jets of water or inflammable liquids on the compressor.
- Do not place inflammable objects near the compressor.
- During down-times, turn the pressure switch to position “0” (OFF).
- Never aim the air jet at people or animals (fig. 34)
- Do not transport the compressor while the tank is pressurised.
- Be careful with regard to some parts of the compressor such as the
head and delivery tubes, as they can reach high temperatures. Do
not touch these parts to avoid burns.(fig. 18 - 19)
- Transport the compressor, lifting or pulling it with the appropriate
grips or handles (fig. 4 - 6)
- Keep children and animals well away from the machine operating
area.
- If using the compressor for painting:
a) Do not work in closed environments or near to naked flames
b) Make sure there is adequate exchange of air at the place of work
c) Protect your nose and mouth with an appropriate mask. (fig. 35)
- If the electrical cable or plug are damaged, do not use the compres-
sor and contact an authorised service centre to replace the faulty el-
ement with an original spare part.
- If the compressor is located on a shelf or on a to
p above floor
height, t must be secured to prevent it falling while in operation.
- Do not put objects or your hands inside the protective grilles to
avoid njury to yourself or damaging the compressor. (fig. 36)
- Do not use the compressor as a blunt object toward things or ani-
mals, o avoid serious damage.
- When you have finished using the compressor, always remove the
lug from the power socket.
N.B. Two-stage compressors can be supplied on request for use up
to 4 bar. In this case:
Maximum operating pressure 14.75 bar
Minimum operating pressure 14 bar
NOTE: For the European market, the compressor tanks are manufac-
tured to meet Directive CE87/404
For the European market, the compressors are manufactured to meet
Directive 2006/42 EC.
The level of acoustic pressure can increase from 1 to 10 dB(A) ac-
cording to the place in which the compressor is installed.
HINTS FOR EFFICIENT OPERATION
- For efficient operation of the machine at full continuing load and at
maximum operating pressure, make sure the temperature of the work
environment indoors does not exceed +25°C.
- We advise you to use the compressor at 70% maximum duty per
hour at full load as this ensures efficient operation of the product
long-term.
STORING THE PACKED AND UNPACKED COMPRESSOR
For the whole time that the compressor is not used before unpacking
it, store it in a dry place at a temperature between +5°C and + 45°C
and sheltered away from weather.
For the whole time that the compressor is not used after unpacking it,
while waiting to start it up or due to production stoppages, place
sheets over it to protect it from dust, which may settle on the compo-
nents. The oil is to be replaced and the operational efficiency of the
compressor is to be checked if it is not used for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed air with
maximum pressure characteristics that are adequate for the com-
pressor.
Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WITHOUT PRIOR NOTICE WHENEVER NECESSARY.
FR
17
INFORMATIONS IMPORTANTES
Lire attentivement toutes les instructions de fonctionnement, les con-
signes de sécurité et les mises en garde contenues dans ce manuel
avant de faire fonctionner le compresseur ou de procéder à son en-
tretien.
La majorité des accident résultant de l’utilisation ou de l’entretien du
compresseur sont dus au non respect des consignes et règles de
sécurité élémentaires. En indentifiant à temps les situations potentiel-
lement dangereuses et en observant les consignes de curité ap-
propriées, on évite bien souvent des accidents.
Les consignes élémentaires de sécurité sont décrites dans la section
“SÉCURITÉ” de ce manuel ainsi que dans les sections renfermant
les instructions d’utilisations et d’entretien.
Ne jamais utiliser le compresseuer d’une manière autre que celle
spécifiquement recommandées, à moins de s’être prélablement as-
suré que l’utilisation envisagée ne sera dangereuse ni pour soi ni
pour les autres.
SIGNIFICATION DU VOCABULAIRE DE SIGNALISATION
AVERTISSEMENT: indique une situation potentiellement dange-
reuse qui, s’il n’est pas tenu compte de son caractère, risque de pro-
voquer de graves blessures.
PRÉCAUTION: indique une situation dangereuse qui, s’il n’est pas
tenu compte de son caractère, risque de provoquer des blessures
légères ou d’endommager la machine.
REMARQUE: souligne une information essentielle
SÉCURITÉ
CONSIGNES DE SÉCURITÉ IMPORTANTES POUR
L’UTILISATION DU COMPRESSEUR AVERTISSEMENT:
UNE UTILISATION DU COMPRESSEUR DE MANIÈRE INCOR-
RECTE OU QUI NE RESPECTE PAS LES CONSIGNES DE SÉCU-
RITÉ PEUT ENTRAÎNER LA MORT OU DE GRAVES BLESSURES.
POUR ÉVITER TOUT DANGER, OBSERVER CES CONSIGNES
ÉLÉMENTAIRES DE SÉCURITÉ.
BIEN LIRE TOUTES LES INSTRUCTIONS
1. NE JAMAIS TOUCHER AUX PIÈCES MOBILES
Ne jamais approcher les mains, les doigts ou aucune autre partie du
corps des pièces mobiles du compresseur.
2. NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SI
TOUS LES GARDES PROTECTEURS NE SONT PAS EN PLACE
Ne jamais faire fonctionner le compresseur si tous les gardes protec-
teurs ou dispositifs de sécurité ne sont pas en place et en bon état. Si
une opération d’entretien ou de réparation nécessite le démontage
d’un garde protecteur ou d’un dispositif de sécurité, bien le remonter
avant de remettre le compresseur en marche.
3. TOUJOURS SE PROTÉGER LES YEUX
Toujours porter des lunettes ou un masque de protection oculaier.
Ne jamais diriger le jet d’air comprimé sur une personne ou une par-
tie du corps.
4. SE PROTÉGER CONTRE LES DÉCHARGES ÉLECTRIQUES
Empêcher tout contact du corps avec les surfaces mises à la terre,
par exemple les tuyaux, radiateurs, plaques de cuisson et enceintes
de réfrigération. Ne jamais faire fonctionner le compresseur dans un
endroit humide ou sur une surface mouillée.
5. DÉBRANCHER LE COMPRESSEUR
Toujours débrancher le compresseur de sa source d’alimentation et
évacuer l’air comprimé de son réservoir avant toute opération de ré-
paration, d’inspection, d’entretien, de nettoyage, de remplacement ou
de vérification des pièces.
6. ÉVITER TOUTE MISE EN MARCHE ACCIDENTELLE
Ne pas transporter le compresseur alors qu’il est encore raccordé à
sa source d’alimentation ou que le réservoir d’air comprimé est
plein.Bien s’assurer que le sélecteur de l’interrupteur barométrique se
trouve sur la position “OFF” (arrêt) avant de raccorder le compres-
seur à son alimentation.
7. ENTREPOSER CORRECTEMENT LE COMPRESSEUR
Veiller à ce qu’il soit hors de portée des enfants. Fermer à clé le local
d’enterposage.
8. MAINTENIR L’AIRE DE TRAVAIL PROPRE
Une aire de travail encombrée augemente les risque d’accident. La
débarrasser des outils inutiles, débris, meubles, etc.
9. SE SOUCIER DE L’ENVIRONMENT DE TRAVAIL
Ne pas exposer le compresseur à la pluie. Ne pas l’utiliser dans un
endroit humide ou sur une surface mouillée. Veiller à ce que l’aire de
travail soit bien éclairée et bien aérée. Ne pas utiliser le compresseur
en présence de liquides ou de gaz inflammables. Les compresseur
projette des étincelles pendant qu’il fonctionne. Ne jamais l’utiliser à
proximité de laque, de peinture, de benzine, de diluant, d’essence, de
gaz, de produits adhésifs ou de tout autre produit combustible ou ex-
plosif.
10. ÉLOIGNER LES ENFANTS
Ne pas laisser les visiteurs toucher aur cordon de rallonge du com-
presseur. Tous les visiteurs devront se tenir suffisamment éloignés
de l’aire de travail.
11. SE VÊTIR CORRECTEMENT
Ne porter ni vêtements lâches ni bijoux. Ils pourraient se prendre
dans les pièces mobiles. Porter un coiffe recouvrant les cheveux
longs.
12. FAIRE ATTENTION AU CORDON
Ne jamais tirer brusquement sur le cordon pour le débrancher. Tenir
le cordon loin des sources de chaleur, de graisse et des surfaces
tranchantes.
13. ENTRETENIR LE COMPRESSEUR AVEC SOIN
Suivre les instructions de lubrification. Inspecter régulièrement les
cordons et, s’il sont endommagés, les faire réparer dans un centre de
service après-vente agrée. Inspecter périodiquement les cordons de
rallonge et les faire réparer s’ils sont endommagés.
14. CORDONS DE RALLONGE POUR UTILISATION À
L’EXTÉRIEUR
Si l’outil doit être utilisé dehors, utiliser exclusivement des cordons de
rallonge conçus pour l’extérieur et identifiés comme tels.
15. RESTER SUR SES GARDES
Bien faire attention à ce que l’on fait. Faire preuve de bon sens. Ne
pas utiliser le compresseur lorsque l’on est fatigués. Ne jamais utiliser
le compresseur si l’on est sous l’effet d’alcool, de drogues ou de mé-
dicaments causant de la somnolence.
16. CONTRÔLER LES PIÉCES ENDOMMAGÉES ET LES FUITES
D’AIR
Avant de continuer à utiliser le compresseur, inspecter attentivement
les protections ou autres pièces endommagées pour s’assurer que le
compresseur pourra fonctionner correctement et effectuer le travail
pour lequel il est conçu. Vérifiez l’alignement et le couplage des
pièces mobiles, la présence de pièces brisées, le montage, les fuites
d’air et tout autre élément susceptible d’altérer le bon fonctionne-
ment.
17. UTILISER LE COMPRESSEUR EXCLUSIVEMENT POUR LES
APPLICATIONS SPÉCIFIÉES DANS LE MANUEL D’UTILISATION
Ne jamais utiliser le compresseur pour des utilisations autres que
celles spécifiées dans le manuel.
18. MANIPULER LE COMPRESSEUR CORRECTEMENT
Faire fonctionner le compresseur conformément aux instructions de
ce manuel. Ne jamais laisser les enfants, les personnes non
familiarisées avec son fonctionnement ou toute personne non autori-
sée utiliser le compresseur.
19. VÉRIFIER QUE CHAQUE VIS, BOULON ET COUVERCLE EST
SOLIDEMENT VISSÉ
Veiller à ce que chaque vis, boulon et plaque soit solidement vissé.
Vérifier périodiquement le serrage.
20. MAINTENIR L’ÉVENT D’AÉRATION DU MOTEUR PROPRE
L’évent d’aération du moteur doit rester propre en permanence de
façon à ce que l’air puisse circuler librement. Contrôler fréquemment
l’accumulation de poussière.
21. FAIRE FONCTIONNER LE COMPRESSEUR À LA TENSION
NOMINALE
Faire fonctionner le compresseur à la tension spécifiée sur la plaque
signalétique. Si le compresseur est utilisé à une tension supérieure à
la tension nominale, il en résultera une vitesse de rotation du moteur
anormalement élevée risquant d’endommager le compresseur et de
griller le moteur.
22. NE JAMAIS UTILISEER UN COMPRESSEUR DÉFECTUEUX
OU DONT LE FONCTIONNEMENT EST ANORMAL
Si le compresseur semble ne pas fonctionner, s’il émet un bruit bi-
zarre ou qu’il semble défectueux, l’arrêter immédiatement et le faire
réparer dans un centre de service après-vente agrée.
23. NE PAS NETTOYER LES PIÈCES DE PLASTIQUE AVEC DU
SOLVANT
Les solvants tels qu’essence, diluant, benzine, tétrachlorure de car-
bone et alcool risquent d’endommager et de fendre les pièces de
plastique. Ne pas les nettoyer avec ce genre de produit. Pout net-
toyer le pièces de plastique, utiliser un linge doux humecté d’eau sa-
vonneuse puis sécher complètement.
FR
18
24. UTILISER EXCLUSIVEMENT DES PIÈCES DE RECHANGE
D’ORIGINE
L’utilisation de pièces de rechange autres que celles fabriquées, peut
entraîner l’annulation de la garantie et être la cause d’un mauvais
fonctionnement et des blessures en résultant. Les pièces d’origine
sont disponible auprès de son distributeur.
25. NE PAS MODIFIER LE COMPRESSEUR
Ne pas modifier le compresseur. Toujours consulter un centre de
service après-vente agréé pour toute réparation. Une modification
non autorisée risque non seulement d’affecter les performances du
compresseur, mais également d’être la cause d’accidents et de bles-
sures pour le personnel de réparation qui ne posséderait pas les
compétences techniques nécessaires.
26. DÉSACTIVER L’INTERRUPTEUR BAROMÈTRIQUE LORS-
QU’ON NE SE SERT PAS DU COMPRESSEUR
Quand le compresseur ne fonctionne pas, régler le sélecteur de
l’interrupteur barométrique sur “OFF”, débrancher le compresseur et
ouvrir le robinet de vidange pour vider le réservoir d’air comprimé.
27. NE JAMAIS TOUCHER LES SURFACES CHAUDES
Pour éviter tout risque de brûlures, ne pas toucher les tubes, les cu-
lasses ni les moteurs.
28. NE PAS DIRIGER LE JET D’AIR DIRECTEMENT SUR LE
CORPS
Sous peine de blessures, ne pas diriger le jet d’air sur des personnes
ou des animaux.
29. VIDANGER LE RÉSERVOIR
Vidanger le réservoir tous les jours ou toutes les 4 heures
d’utilisation.
Ouvrir le bouchon de vidange et incliner le compresseur pour vider
l’eau qui s’est accumulée.
30. NE PAS ARRÊTER LE COMPRESSEUR EN TIRANT SUR LA
FICHE
Utiliser la position “AUTO/OFF” du sélecteur de l’interrupteur baromé-
trique.
31. POUR LE CIRCUIT PNEUMATIQUE
N’utiliser que des pièces pneumatiques recommandées supportant
une pression supérieur ou égale.
PIÈCES DE RECHANGE
Pour le réparations, utiliser uniquement des pièces de rechange iden-
tiques aux pièces remplacées.
Confier toute réparation à un centre de service après-vent agréé.
AVERTISSEMENTS
INSTRUCTIONS POUR LE BRANCHEMENT A LA TERRE
Ce compresseur doit être relié à la terre lorsqu’il est en cours
d’utilisation afin de protéger l’opérateur des décharges électriques.
Le compresseur monophasé est équipé d’un câble bipolaire plus
terre.
Le compresseur triphasé est fourni avec un câble électrique sans
fiche.
Le branchement électrique doit être exécuté par un technicien quali-
fié.
Il est recommandé de ne jamais démonter le compresseur ni effec-
tuer d’autres connexions au niveau du pressostat.
Les réparations doivent être effectuées uniquement par des centres
de service après-vente autorisés ou par d’autres centres qualifiés.
Ne jamais oublier que le fil de mise à la terre est le fil vert ou
jaune/vert. Ne jamais brancher ce fil vert à une extrémité vive.
Avant de remplacer la fiche du câble d’alimentation, vérifier que le
branchement du fil de terre est effectué.
En cas de doute contacter un électricien qualifié et faire contrôler la
mise à la terre.
RALLONGE
Utiliser uniquement une rallonge avec fiche et branchement à la
terre,
ne pas utiliser de rallonges endommagées ou écrasées.
Vérifier que la rallonge soit en bon état.
Contrôler que la section du câble de rallonge soit suffisante pour
supporter le courant absorbé par le produit qui sera branché.
Une rallonge trop fine peut provoquer des chutes de tension et, par
conséquent, une perte de puissance ainsi qu’une surchauffe de
l’appareil.
Le câble de rallonge des compresseurs monophasés doit avoir une
section proportionnée à sa longueur, voir tableau (tab.1)
Tab. 1 SECTION VALABLE POUR UNE LONGUEUR
MAXIMUM DE 20 mt monophasé
CH
Kw
220/230 V
[mm
2
]
110/120 V
[mm
2
]
0,75 - 1
0,65–0,7 1,5 2,5
1,5 1,1 2,5 4
2 1,5 2,5 4 – 6
2,5 - 3 1,8 – 2,2 4 /
Le câble de rallonge des compresseurs triphasés doit avoir une sec-
tion proportionnée à sa longueur : voir tableau (tab. 2).
Tab. 2 SECTION VALABLE POUR UNE LONGUEUR
MAXIMUM DE 20 m. triphasé
C
H
Kw
220/230 V
[mm
2
]
380/400V
2-3-4 1,5-2,2-3 2,5 1.5
5,5 4 4 2.5
7,5 5,5 6 2.5
10 7,5 10 4
15 11 16 10
20 15 25 16
AVERTISSEMENTS
Eviter tous les risques de décharges électriques.
Ne jamais utiliser le compresseur avec une rallonge ou un câble élec-
trique endommagé.
Contrôler régulièrement les câbles électriques.
Ne jamais utiliser le compresseur dans l’eau ou à proximité de celle-
ci ainsi qu’à proximité d’un lieu avec risque de décharges électriques.
CONSERVER LES INSTRUCTIONS D’UTILISATION ET
D’ENTRETIEN ET LES METTRE A DISPOSITION DES PER-
SONNES QUI UTILISENT CET APPAREIL!
REMARQUE:Les informations indiquées dans ce manuel ont pour
objectif d’assister l’opérateur durant l’utilisation et les opérations
d’entretien du compresseur.
Certaines illustrations de ce manuel indiquent certains détails qui
peuvent être différents de ceux de votre compresseur.
INSTALLATION
Après avoir déballé le compresseur (fig. 1), vérifier qu’il est en bon
état en contrôlant qu’il n’ait pas subi de dommages durant la trans-
port puis effectuer les opérations suivantes:
Monter les roues et le caoutchouc sur les réservoirs (lorsqu’ils ne
sont pas déjà montés) en suivant les instructions de la fig. 2. En cas
de roues gonflables, gonfler à une pression maximale de 1,6 bar (24
psi).
Positionner le compresseur sur une surface plane ou avec une incli-
naison maximale de 10° (fig. 3), dans un lieu bien ventilé, à l’abri des
agents atmosphériques et non dans des endroits présentant des
risques d’explosion. En cas de plan incliné et lisse, vérifier que le
compresseur ne se déplace pas en cours de fonctionnement, dans le
cas contraire,bloquer les roues avec deux cales.
Si le plan est un support ou un échafaudage, fixer le compresseur de
façon appropriée afin d’éviter les chutes.
Pour obtenir une bonne ventilation et un refroidissement efficace, il
estimportant que la protection courroie du compresseur soit à au
moins100 cm de distance de toute cloison (fig. 4).
Les compresseurs montés sur réservoir à pieds fixes ne doivent
pasêtre fixés au sol de façon rigide, il est conseillé de monter 4 sup-
portsantivibrants.
INSTRUCTIONS D’UTILISATION
– Faire attention que le compresseur soit transporté correctement, ne
pas le retourner ou le soulever avec des crochets ou câbles (fig. 5 –
6).
Remplacer le bouchon en plastique situé sur le couvercle carter
(fig.7 – 8) avec la tige de niveau d’huile (fig. 9) ou avec le bouchon de
purge approprié (fig. 10) fourni avec le manuel d’instructions, contrô-
ler le niveau d’huile en prenant les encoches situées sur la tige (fig.
9) ou le témoin de niveau d’huile (fig. 11) comme référence.
FR
19
BRANCHEMENT ELECTRIQUE
Les compresseurs monophasés sont fournis avec un câble bipo-
laire et une fiche bipolaire + terre.
Il est important que le compresseur soit branché à une prise de cou-
rant doté de mise à la terre (fig. 12).
Les compresseurs triphasés (L1 - L2 - L3 - PE) doivent être installés
par un technicien qualifié.
Les compresseurs triphasés sont fournis sans fiche.
Relier au câble d’alimentation une fiche électrique avec passe-câble
à vis et collier de blocage (fig. 13) après avoir consulté le tableau ci-
dessous.
CH
Kw
Aliment. volt/ph
Type de f
iche
2-3-4 1,5-2,2.3 220/230/3
16 A 3
pôles + terre
380/400/3
16 A 3
pôles + terre
5,5-7,5-10 4-5,5-7,5 220/230/3
32 A 3
pôles + terre
380/400/3
32 A 3
pôles + terre
15 - 20 11 - 15 220/230/3
63 A 3
pôles + terre
380/400/3
32 A 3
pôles + terre
REMARQUE: Les compresseurs montés sur réservoir de 500 l. avec
une puissance de CH7.5/55 kW et CH10/7.5 sont disponibles avec
boîtier de démarrage étoile/triangle.
Pour l’installation, procéder comme suit:
Fixer le boîtier au mur ou sur un support fixe, l’équiper d’un câble
d’alimentation avec fiche électrique et d’une section proportionnée à
la longueur.
Tout dommage provoqué par de mauvais branchements à la ligne
annule automatiquement la garantie sur les pièces électriques. Afin
d’éviter tout branchement incorrect, contacter un technicien qualifié.
ATTENTION: Ne jamais utiliser la prise de terre à la place du neutre.
Le branchement à la terre doit être effectué selon les normes de pré-
vention des accidents du travail (EN 60204).
La fiche du câble d’alimentation ne doit pas être utilisée comme inter-
rupteur mais doit être introduite dans une prise de courant comman-
dée par un interrupteur différentiel approprié (magnétothermique).
DEMARRAGE
Contrôler que la tension de réseau correspond à celle indiquée sur la
plaquette signalétique des caractéristiques électriques (fig. 14), la
plage de tolérance admise est de ± 5%.
Au moment de la première mise en service, pour les compresseurs
qui fonctionnent avec une tension triphasée, vérifier le sens exact de
rotation du ventilateur de refroidissement au moyen de la flèche si-
tuée sur la protection courroie ou sur le carénage.
Tourner ou appuyer, en fonction du type de pressostat présent sur
l’appareil, le pommeau situé sur la partie supérieure en position “0
(fig. 15).
Introduire la fiche dans la prise de courant (fig. 12 - 13) et démarrer le
compresseur en positionnant le pommeau du pressostat sur (I).
Le fonctionnement du compresseur est entièrement automatique,
commandé par le pressostat qui l’arrête lorsque la pression dans le
réservoir atteint la valeur maximum et le fait repartir lorsqu’elle des-
cend en dessous de la valeur minimum.
Généralement, la différence de pression entre la valeur maximum et
la valeur minimum est d’environ 2 bars (29 psi).
Ex.: le compresseur s’arrête lorsqu’il atteint 8 bars (116 psi) (pression
maximum de fonctionnement) et redémarre automatiquement lorsque
la pression à l’intérieur du réservoir descend à 6 bars (87 psi).
Après avoir branché le compresseur à la ligne électrique, effectuer
une charge à la pression maximum et vérifier que le fonctionnement
de la machine soit correct.
COMPRESSEURS AVEC BOITIER DE DEMARRAGE D (fig. 16)
Introduire la fiche dans la prise de courant (fig.13), positionner le
pressostat sur “I” (ON) (fig. 17).
Tourner l’interrupteur principal d’alimentation “A” du boîtier sur “I”, la
présence du courant est signalé par l’allumage du témoin blanc “E”.
l’allumage du témoin électrovanne “D” tout d’abord puis du moteur
(C) ensuite signalent que le fonctionnement de la machine est parfait
(fig. 18).
COMPRESSEURS TANDEM AVEC BOITIER TEMPORISE (fi g.17)
Introduire la fi che dans la prise de courant (fi g. 13), positionner le
pressostat sur “I” (ON).
Tourner l’interrupteur principal d’alimentation “A” du boîtier sur 1, la
présence du courant est signalé par l’allumage du témoin blanc (E);
tourner l’interrupteur “B” pour démarrer le compresseur.
Pos. 1 seule la pompe 1 fonctionne
Pos. 2 seule la pompe 2 fonctionne
Pos. 3 les deux pompes fonctionnent simultanément, avec un départ
différencié.
Le fonctionnement du compresseur est entièrement automatique,
commandé par le pressostat qui l’arrête lorsque la pression dans le
réservoir atteint la valeur maximum et le fait repartir lorsqu’elle de-
scend
à la valeur minimum.
ATTENTION
Les électrocompresseurs doivent être branchés à une prise de cou-
rant protégée par un interrupteur différentiel adapté (magnétother-
mique).
Le moteur des compresseurs coaxial est doté d’une protection ther-
mique automatique située à l’intérieur de l’enroulement, elle arrête le
compresseur lorsque la température du moteur atteint des valeurs
trop élevées.
En cas d’intervention, le compresseur repart automatiquement après
10 - 15 minutes.
Les moteurs des compresseurs modèle coaxial duoble cylindre sont
dotés d’une protection thermique ampèremétrique automatique à ré-
armement manuel, située à l’extérieur, sur le couvercle du bornier.
Lorsque la protection thermique intervient, attendre quelques minutes
puis réarmer manuellement l’interrupteur thermique (fig. 20).
Les moteurs monophasés des compresseurs de la série à courroie
sont dotés d’une protection thermique ampèremétrique à réarmement
manuel, située sur le couvercle du bornier.
Lorsque la protection thermique intervient, attendre quelques minutes
puis réarmer manuellement l’interrupteur thermique (fig. 20).
En cas d’intervention de la protection thermique, le pressostat se dé-
sactive, position “0” (OFF), attendre quelques minutes puis reposi-
tionner le pressostat sur “I” (ON). Sur les compresseurs équipés d’un
boîtier, la protection thermique se trouve à l’intérieur du boîtier.
En cas d’intervention de la protection thermique, procéder de la façon
suivante (fig. 22):
Positionner les interrupteurs situés sur le couvercle du boîtier sur
“0”, ouvrir le couvercle et appuyer sur le bouton-poussoir 1 de la pro-
tection thermique. Refermer le couvercle du boîtier et démarrer le
compresseur en suivant les opérations décrites au paragraphe
“Compresseurs avec boîtier de démarrage”.
Effectuer les mêmes opérations pour les compresseurs avec alimen-
tation à 60 Hz.
REGLAGE DE LA PRESSION DE FONCTIONNEMENT (fig. 23)
Il n’est pas nécessaire d’utiliser toujours la pression de fonctionne-
ment maximum, dans la plupart des cas l’outil pneumatique relié né-
cessite une pression moins élevée.
Sur les compresseurs dotés d’un réducteur de pression, il est néces-
saire de régler correctement la pression de fonctionnement.
Débloquer le pommeau du réducteur de pression en tirant vers le
haut, régler la pression à la valeur désirée en tournant le pommeau
dans le sens des aiguilles d’une montre pour l’augmenter et dans le
sens contraire pour la diminuer; une fois la pression optimale atteinte,
bloquer le pommeau en appuyant vers le bas (fig. 23).
Sur les réducteurs de pression sans manomètre, la pression de ré-
glage est visible sur l’échelle graduée située sur le corps du réduc-
teur.
Sur les réducteurs de pression avec manomètre, la pression de ré-
glage est visible sur l’échelle graduée située sur le manomètre.
ATTENTION: Certains réducteurs de pression ne sont pas équipés
de "push to lock", par conséquent, il suffit de tourner la poignée pour
en régler la pression.
ENTRETIEN
Avant d’effectuer toute intervention sur le compresseur vérifier que:
– L’interrupteur principal de ligne soit sur la position “0”.
Le pressostat et les interrupteurs du boîtier soient désactivés, posi-
tion “0”.
– Le réservoir d’air soit déchargé de toute pression.
Toutes les 50 heures de fonctionnement, il convient de démonter le
filtre d’aspiration et de nettoyer l’élément filtrant en soufflant de
l’air comprimé (fig. 24).
Il est conseillé de remplacer l’élément filtrant au moins une fois lors-
que le compresseur fonctionne dans un endroit propre; plus souvent
en cas d’endroit poussiérieux..
FR
20
Il est nécessaire d’évacuer la condensation du réservoir au moins
une fois par semaine en ouvrant le robinet de vidange (fig. 26) situé
sous le réservoir.
En cas de présence d’air comprimé à l’intérieur de la bouteille, faire
particulièrement attention car l’eau est susceptible de sortir avec
force. Pression conseillée 1-2 bars maxi.
La condensation du compresseur lubrifié avec de l’huile ne doit pas
être vidée dans les égouts ou déverser dans l’environnement car elle
contient de l’huile.
VIDANGE D’HUILE – ADJONCTION D’HUILE
Le compresseur est fourni avec de l’huile synthétique. Après les 100
premières heures de fonctionnement, il est conseillé de vidanger
complètement l’huile du compresseur. Dévisser le bouchon de vi-
dange situé sur le couvercle carter, faire sortir toute l’huile, revisser le
bouchon (fig. 27 - 28).
Introduire l’huile par l’orifice supérieur du couvercle carter (fig. 30-31)
jusqu’à l’obtention du niveau indiqué sur la tige (fig. 9) ou sur le té-
moin (fig. 11).
Introduire l’huile par l’orifice supérieur de la tête (fig. 30) sur les
groupes à courroie prédisposés pour le remplissage au niveau de
cette zone.
Toutes les semaines, contrôler le niveau d’huile de la pompe (fig. 11),
ajouter de l’huile si nécessaire.
En cas de fonctionnement à une température ambiante de -5°C à
+40°C, utiliser de l’huile synthétique.
L’huile synthétique offre l’avantage de ne pas perdre ses caractéris-
tiques tant durant l’hiver que durant l’été. L’huile usagée ne doit pas
être vidée dans les égouts ou déverser dans l’environnement.
CONSULTER LE TABLEAU
TYPE D’HUILE HEURES DE FONCTIONNEMENT
Huile Synthetique.................................500
PETITES ANOMALIES
Fuite d’huile depuis la vanne située sous le pressostat
Cet inconvénient est dû à une étanchéité défectueuse de la vanne de
retenue, procéder comme suit (fig. 31):
- Evacuer toute la pression du réservoir
- Dévisser la tête hexagonale de la vanne (A)
- Nettoyer soigneusement le disque en caoutchouc (B) ainsi que son
logement.
- Remonter soigneusement le tout.
Fuite d’air
Elles sont généralement dues à une étanchéité défectueuse des rac-
cords; contrôler tous les raccords en les mouillant avec de l’eau sa-
vonneuse.
Le compresseur tourne mais ne charge pas
Compresseurs coaxiaux: (fig. 32)
- L’inconvénient peut être dû à la rupture des vannes (C1-C2) ou d’un
joint (B1-B2), remplacer la pièce défectueuse.
Compresseur acheminement par courroie: (fig. 33)
- L’inconvénient peut être à la rupture des vannes F1 et F2 ou
d’un joint (D1-D2), remplacer la pièce défectueuse.
Le compresseur ne démarre pas
En cas de difficulté de démarrage du compresseur, vérifier les points
suivants:
- la tension de réseau doit correspondre à celle indiquée sur la pla-
quette signalétique (fig. 14)
- Aucune rallonge électrique de section ou longueur non adaptée ne
doit être présente.
- le lieu de fonctionnement ne doit pas être en dessous de 0°C.
- En ce qui concerne la série AB, vérifier l’absence d’intervention de
la protection thermique (fig. 20).
- Le carter doit être rempli d’huile afin de garantir la lubrification.
- Le réseau électrique doit être alimenté (prise bien branchée ma-
gnétothermique, fusibles en bon état).
Le compresseur ne s’arrête pas
- Si le compresseur ne s’arrête pas lorsque la pression maximale est
atteinte, la vanne de sécurité du réservoir entre en fonction. Dans ce
cas, il est nécessaire de contacter le centre de service après-vente
autorisé le plus proche pour la réparation.
ATTENTION
- Eviter absolument de dévisser un raccord quelconque lorsque le
réservoir est sous pression, vérifier toujours qu’il soit vide.
- Il est interdit de percer des trous, de faire des soudures ou de dé-
former volontairement le réservoir d’air comprimé.
- Débrancher la fiche de la prise de courant avant d’effectuer toute
opération sur le compresseur.
- Température ambiante de fonctionnement 0°C + 35°C.
- Ne pas diriger de jet d’eau ou de liquide inflammable sur le com-
presseur.
- Ne pas positionner d’objet inflammable à proximité du compresseur.
- Durant les pauses, positionner le pressostat sur “0” (OFF) (éteint).
- Ne jamais diriger le jet d’air vers des personnes ou animaux.
- Ne pas transporter le compresseur lorsque le réservoir est sous
pression.
- Faire attention qu’aucune partie du compresseur tels que tête et
tuyaux de départ ne puissent atteindre des températures élevées.
Ne jamais toucher ces composants afin éviter les brûlures.
- Transporter le compresseur en le soulevant ou en le tirant par les
poignées ou prises appropriées (fig. 4 - 6).
- Eloigner les enfants et les animaux de la zone de fonctionnement
de la machine.
- En cas d’utilisation du compresseur pour peindre :
a) Ne pas opérer dans les lieux fermés ou à proximité de flammes
libres
b) Vérifier que la pièce dans laquelle la machine fonctionne bénéficie
d’un changement d’air.
c) Protéger nez et bouche à l’aide d’un masque approprié (fig. 35)
- En cas d’endommagement du câble électrique ou de la fiche, ne
pas utiliser le compresseur et contacter le centre de service après-
vente autorisé pour les remplacer par une pièce originale.
- En cas de positionnement du compresseur sur un échafaudage ou
un plan au-dessus du sol, le fixer afin d’éviter toute chute durant le
fonctionnement.
- Ne pas introduire d’objets ou les mains à l’intérieur des grilles de
protection afin d’éviter tout accident ou dommage du compresseur.
- Eviter d’utiliser le compresseur comme objet contondant contre des
personnes, animaux ou choses afin d’éviter des accidents graves.
- Une fois l’utilisation du compresseur terminée, toujours débrancher
la fiche de la prise de courant.
N.B.: Sur demande, les compresseurs à deux étages peuvent être
fournis pour une utilisation jusqu’à 14 bars. Dans ce cas:
Pression maximum de fonctionnement: 14.75 bars
Pression maximum d’utilisation: 14 bars
REMARQUE: Pour le marché européen, les réservoirs des compres-
seurs sont fabriqués selon la Directive CE2006/105
Pour le marché européen, les réservoirs des compresseurs sont fa-
briqués selon la Directive 2006/42 EC.
CONSEILS UTILES POUR UN FONCTIONNEMENT CORRECT
- Pour un fonctionnement correct de la machine en pleine charge
continue à la pression de fonctionnement maximum, vérifier que la
température dans un local fermé ne dépasse pas + 25°C.
- Il est conseillé d’utiliser le compresseur avec un service maximum
de 70% pendant une heure en pleine charge, ceci afin de permettre
un fonctionnement correct du produit dans le temps.
STOCKAGE DU COMPRESSEUR EMBALLÉ ET DÉBALLÉ
Pendant toute la période d’inactivité du compresseur avant son -
ballage, l’emmagasiner dans un lieu sec, avec une température com-
prise entre + 5°C et + 45°C et en position permettant d’éviter le con-
tact avec les agents atmosphériques.
Pendant toute la période d’inactivité du compresseur après son -
ballage, dans l’attente de sa mise en service ou en cas d’interruption
de production, le protéger avec des bâches afin d’éviter que la pous-
sière se dépose sur les mécanismes.
Si le compresseur reste inactif pendant de longues périodes, il est
nécessaire de vidanger l’huile et de contrôler le fonctionnement.
RACCORDEMENTS PNEUMATIQUES
Utiliser toujours des tuyaux pneumatiques pour air comprimé ayant
des caractéristiques de pression maximum adaptées à celle du com-
presseur.
Ne pas essayer de réparer le tuyau lorsqu’il est défectueux.
EN CAS DE NECESSITE, NOUS NOUS RESERVONS LE DROIT
D’APPORTER TOUTE MODIFICATION NECESSAIRE SANS
PREAVIS.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Blitz TWIN Works 530/300 H Le manuel du propriétaire

Catégorie
Compresseurs d'air
Taper
Le manuel du propriétaire