Harman® • P42i Owner’s Manual • 2023 -___ • 03/2328742-900A
Congratulations, The Harman® P42i-TC pellet insertyou
have selected is designed to provide the utmost in safety,
reliability,andeciency.
As the owner of a new pellet stove, you’ll want to read and
carefully follow all of the instructions contained in this owner’s
manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
YournewHarman®P42i-TCPelletInsertwillgiveyouyears
ofdurableuseandtrouble-freeenjoyment.Welcometothe
Harman® family!
Note: Cast iron is an artisan crafted material, which is
made the same way today as nearly 2000 years ago.
Due to the intrinsic primitive nature of the casting
process, part to part variation is normal and adds to the
character of a hand built cast iron appliance
Read this manual before operating this appliance.
Please retain this Owner’s Manual for future reference.
Read the Installation Manual before making any installation or nishing changes.
Listing Label Information/Location Themodelinformationregardingyourspecicstovecanbefoundonthe
rating plate usually located in the control area of the stove.
Ce poêle à granulés a été testé et peut être installé dans les maisons
préfabriquées en conformité avec OAR 814-23-9000 à 814-23-909
PRÉVENTION DES INCENDIES Respecter scrupuleusement les
instructions du constructeur pour l’installation et les consignes de
fonctionnement. Respecter les règles de sécurité en vigueur dans votre
région.
Ce poêle à bois doit inspection périodique et la réparation pour un
fonctionnement correct. Consultez le manuel du propriétaire pour plus
d’informations. Ce est contre les règlements fédéraux pour faire fonctionner
ce poêle à bois d’une manière incompatible avec les instructions
d’utilisation dans le manuel du propriétaire.
AVERTISSEMENT : POUR LES MAISONS FABRIQUES: Ne pas installer
dans une chambre. Il est impératif de prévoir une prise d’air extérieur.
L’intégrité structurale du plancher, du plafond et des murs doit être
strictement préservée.
Se reporter aux instructions du fabricant et aux réglementations spécifi ques
locales concernant les précautions requises lorsque la cheminée traverse
un mur ou un plafond fabriqué en matière combustible.
Contrôler et nettoyer fréquemment tout le système d’évacuation des
fumées conformément aux recommandations du constructeur.
Utiliser un conduit de fumée type « L » ou « PL » d’un diamètre de 7,6 cm
(3”) ou de 10 cm (4”), ou bien une gaine en acier inoxydable de 10 cm (4”),
comme indiqué dans le manuel d’utilisation.
Ne pas raccorder ce poêle à un conduit
de cheminée déjà utilisé pour un autre
appareil.
À UTILISER AVEC LA GRANULE DE BOIS
SEULEMENT.
Émissions certifi és EPA: 1,0 g / h
Consommation maximum: 2,36 kg/h
Caractéristiques électriques:
120 V c.a. – 60 Hz – Intensité au
démarrage 5,0 A
Intensité en fonctionnement normal 4,0 A
DANGER: Risque d’électrocution.
Débrancher l’appareil avant toute
intervention.
Pour une information plus complète, se
reporter à la notice d’utilisation.
Ne remplacer la vitre qu’avec une vitre
céramique 5 mm disponible auprès de
votre revendeur.
Garder la porte vitrée bien close
durant le fonctionnement de l’appareil.
Report #/Rapport #22-858
Tested to/Testé selon: ASTM E2779, ASTM E2515, ASTM
E1509, ULC-S628, Pellet Fuel-Burning Type, Also For Use In
Manufactured Homes. (UM) 84-HUD
“PREVENT HOUSE FIRES” Install and use only in accordance
with the manufacturer’s installation and operation instructions.
Contact local building or fi re offi cials about restrictions and
installation inspection in your area.
This wood heater needs periodic inspection and repair for proper
operation. Consult the owner’s manual for further information.
It is against federal regulations to operate this wood heater in a
manner inconsistent with the operating instructions in the owner’s
manual.
Room Heater, Pellet Fuel-Burning Type, Also for Use in
Manufactured Homes
WARNING: FOR MANUFACTURED HOMES: Do not install
appliance in a sleeping room. An outside combustion air inlet must
be provided. The structural integrity of the manufactured home
fl oor, ceiling and walls must be maintained.
Refer to manufacturer’s instructions and local codes for precautions
required for passing chimney through a combustible wall or ceiling.
Inspect and clean exhaust venting system frequently in
accordance with manufacturer’s instructions.
Use a 3” or 4” diameter type “L” or “PL” venting system, or 4”
stainless steel fl ex as per owner’s manual.
Do not connect this unit to a chimney fl ue servicing another
appliance.
FOR USE WITH PELLETIZED WOOD FUEL ONLY.
EPA Certifi ed Emissions: 1.0 g/hr
Input Rating Max: 5.2 lb. fuel/hr.
Electrical Rating: 120 VAC, 60 Hz, Start 3.5 AMPS, Run 2.5 AMPS
DANGER: Risk of electrical shock. Disconnect power supply
before servicing.
For further instruction refer to owner’s manual.
Replace glass only with 5mm ceramic available from your dealer.
Keep viewing door tightly closed during operation.
DO NOT REMOVE THIS LABEL/NE PAS ENLEVER CETTE
ÉTIQUETTE
B
12” (305mm) Mantel
A
EE
C
D
Sidewall/Mur latéral
Trim/Panneau de Moulure
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
Non-combustible fl oor protector must extend 6” (152 mm) to the sides
and front of the unit, measured from the glass face.
ÉCARTS MINIMUM DE SÉCURITÉ
La protection de sol doit être constituée de matériau incombustible et
s’étendre de 152 mm (6”) à l’avant et sur les côtés de l’unité, mesurée
depuis la vitre (ÉTATS-UNIS).
8742-930A
A. Corps de l’insert à la paroi latérale - 305mm (12 po)
B. Corps de l’insert à 12” (305mm) Mantel - 305m (12 po)
C. Introduisez le corps de 3/4 “fascia ou couper au-dessus - 0mm (0 po)
D. Corps de l’insert au bord latéral - 203mm (8 po)
E. Protection de sol. Mesurée depuis la vitre. - 152mm (6 po)
BARCODE LABEL
HF
Serial No.
No de série:
A. Insert Body to side wall - 12” (305 mm)
B. Insert Body to 12” (305mm) Mantel - 12” (305 mm)
C. Insert Body to 3/4” fascia or trim above - 0” (0 mm)
D. Insert Body to side trim - 8” (203 mm)
E. Floor protection. Measured from glass. - 6” (152mm)
MODEL / MODÈLE: “P42i-TC Pellet Insert”
Room Heater Pellet Fuel-Burning Type
SUITABLE FOR MOBILE-HOME INSTALLATION
This pellet burning appliance has been tested and listed for use In
Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909
Date of Manufacture / Date de fabrication:
2023 2024 2025 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
US ENVIRONMENTAL PROTECTION AGENCY
Certifi ed to comply with 2020 particulate emission standards.
Certifi é conforme aux normes 2020 d’émission de particules.
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-
d’Amérique par des pièces d’origine américaine et pièces importées.
LABELTICKET
ECO: 96780 LABEL SIZE: 11”x5.75”
PART # / REV: 8742-930A ADHESIVE: N/A
ORIGINATOR: Spidlet MATERIAL: 24 Gauge Aluminum
DATE: 03/27/23 INK: ScreenedBlackBackground
(2)SlottedHoles=.156x.25
(2)Holes=Ø.2
(4)Corners=R.062
This unit will need the addendum label that refers to the
“Wood heater needs periodic inspection” Information
352MountainHouseRoad
Halifax,PA17032
SerialNumber
ModelName
EXAMPLE